CLS 414 Clinical Chemistry Student Lab Rotation: Basic Principles of Electrophoresis Lecture 1
Basic Principles of Electrophoresis
University of Nebraska Medical Center
p
Ricki Otten MT(ASCP)[email protected]
Electrophoresis
Electrophoresis is a separation technique
Technique is used in clinical laboratories to t t i f h th
2
separate proteins from each other: Proteins in body fluids: serum, urine, CSF Proteins in erythrocytes: hemoglobin Nucleic acids: DNA, RNA
Basic Terms
Amphoteric nature of proteins Zwitterion Isoelectric point (pI)
3
The overall charge of the protein is determined bythe number of acidic and basic amino acids in itsbasic structure. Because of their amphotericnature, amino acids can express a net positivecharge, a net negative charge or a net charge ofzero.
4
Net Charge of Molecule
pH of the buffer (reagent) determines the charge of the molecule
5
Net Charge of Molecule
Net charge of molecule determines migration direction in electrical field
6
Cathode Anode(Negative electrode) (Positive electrode)
-
CLS 414 Clinical Chemistry Student Lab Rotation: Basic Principles of Electrophoresis Lecture 2
At one pH, called the isoelectric point (pI), the number of positive and negative charges are equal.
At this pH, the protein exhibits a net zero charge,and is referred to as a zwitterion
7
pI and Zwitterion pI (pH) where molecule remains neutral Will not migrate in an electrical field Remains at application point
8
(cathode -) Net zero charge (anode +)
(will not migrate)
Every amino acid has its own specificisoelectric point. Since proteins are made ofamino acids, all proteins have their own pI
Pre-albumin: pI ~ pH 4.7Albumin: pI ~ pH 4 9
9
Albumin: pI pH 4.9Gamma globulins: pI ~ pH 7.3
How charged a molecule becomes dependson the pH of the buffer and the proteinsisoelectric point
At a pH above its isoelectric point, the proteins will havea net negative charge and will migrate towards the anode
Since pre-albumins isoelectric point (4.7) is the furthest fromthe buffer pH, it is expected to have the greatest charge andmigrate fastest towards the anode
Since the gamma globulins isoelectric point (7.3) is theclosest to the buffer pH, it is expected to have the least
10
charge and migrate slowest towards the anode
Electrophoresis is a separationtechnique based on the principlethat a charged particle in solutionwill migrate towards one of theelectrodes when placed in anelectrical field
11
electrical field
The speed and direction a charged particle moves is determined by the particles:
Net charge (determined by buffer pH)Incr charge = faster speed
12
Incr charge faster speed
-
CLS 414 Clinical Chemistry Student Lab Rotation: Basic Principles of Electrophoresis Lecture 3
The speed and direction a charged particle moves is determined by the particles:
Size and shapeIncr size = slower speed
13
The speed and direction a chargedparticle moves is also influenced byexternal factors such as:
VoltageIncr voltage incr speed incr heat protein denaturation
14
protein denaturation
The speed and direction a charged particle moves is also influenced by external factors such as:
Buffer pHDetermines net charge of protein and therefore direction of migration
15
The speed and direction a charged particle moves is also influenced by external factorssuch as:
Support medium (type of gel)P t i i t ti l d
16
Protein interaction slows speed
The speed and direction a charged particle moves is also influenced by external factors such as:
TemperatureIncr temp Incr speed incr heat leads to denaturation
D t d d
17
Decr temp decr speed
The proteins found in plasma (TSP) all have amino acids astheir subunits, and each protein has its own specificisoelectric point
Because of their different isoelectric points, each protein willmove at a different rate when placed in an electrical field
Proteins with similar isoelectric points will migrate to a similar
18
area in an electrical field
-
CLS 414 Clinical Chemistry Student Lab Rotation: Basic Principles of Electrophoresis Lecture 4
Recall that total serum protein (TSP) is comprised of albumin and globulins.
Electrophoresis separates TSP into 5 distinct zones or bands:
19
The width of each band is dependent upon thenumber of proteins that are present in thatfraction
20
Of these five major fractions, 4 are composed of a number ofadditional proteins of varying size and molecular weight. Theclinically significant proteins are listed:
Transferrin, Complement, beta-( )
alpha-2-macroglobulin, Haptoglobin, Ceruloplasmin
Thyroxine-binding globulin, alpha-1-antitrypsin, alpha-1-lipoprotein (HDL)
21
IgG, IgA, IgM, IgD, IgE and C-reactive protein
Lipoprotein (LDL)
Basic Procedure
1.Sample is applied to an agarose gel 2.Gel is placed into electrophoresis cell
containing barbital buffer at pH 8.6
22
3. Power is applied creating an electricalfield and the proteins are separated
4.Proteins are fixed to the gel and stained
5.Separated proteins on gel are scanned 6.Gel and densitometer scan are
l t d
Instrumentation and Reagents
Electrophoresis cell 2 compartment cell Buffer
2 platinum electrodes
23
2 platinum electrodes Anode Cathode
Negative Electrode = Cathode
24
-
CLS 414 Clinical Chemistry Student Lab Rotation: Basic Principles of Electrophoresis Lecture 5
Instrumentation and Reagents
Power source
Buffer: barbital, pH 8.6
25
Carries applied current Determines charge
and migration direction
Fill Both Compartments of Cell with Buffer
Procedure manual
26
Instrumentation and Reagents Support media
Various types Minimize interactions:
pure and neutral Agarose: often used
27
Agarose: often used Electroendosmosis
effects minimal Clarity: scanning
possible Commercial prep Miniaturization
Native Clarity After Drying
28
Instrumentation and Reagents
Fixative, Stain and Rinse solutions Fix proteins to gel surface Stain proteins to visualize
P t i t i
29
Protein stain Lipid (fat) stain Nucleic acid stain
Excess stain rinsed away
Fixative, Stain and De-stain Solutions: Corrosive
30
-
CLS 414 Clinical Chemistry Student Lab Rotation: Basic Principles of Electrophoresis Lecture 6
Stained Gel
31
De-stained Gel
32
Instrumentation and Reagents
Drying oven De-stained gel is dried
Clear gel ready to scan using densitometer
33
Densitometer
A densitometer is a special type of
34
special type of spectrophotometer usedto measure lighttransmittance through asolid sample such asan electrophoretic strip
DensitometerThe electrophoretic strip is moved past a measuring opticalsystem.
35
The absorbance ofeach band is measured and thearea of each fractionis displayed on astrip chart recorder
DensitometerEach peak represents an individual band on theelectrophoretic strip
36
-
CLS 414 Clinical Chemistry Student Lab Rotation: Basic Principles of Electrophoresis Lecture 7
DensitometerQuantitation is performed by determiningthe area of each band as a percent of thetotal area for that scan
Microprocessors
37
Microprocessors automatically integrate and compute the area under each peak and present the data in both percent and concentration units
Albumin
Alpha-
1-glyc
oprote
in and
alpha-
1-lipop
rotein
Alpha-
1-antit
rypsin
Alpha-
2-macr
oglobu
lin
Hapto
globin Be
ta-lipo
protein
Transf
errin
Comp
lement
C3
IgAIgM IgG
38
Parameters Affecting Electrophoresis
pH Ionic strength of buffer Ions present Current
39
Current Voltage Temperature Time Medium
Technical Considerations
Buffers Barbital bacterial growth pH change Barbital, pH 8.6 most often used Discard after each run
40
Sample Optimal amount of sample applied to gel Avoid overloading: dilute serum prior to
application (0.050 ml serum + 0.2 ml buffer)
Pop Quiz !What is the dilution?
41
0.050 ml serum + 0.2 ml buffer
Pop Quiz !What is the dilution?
42
0.050 ml serum + 0.2 ml buffer0.050 + 0.200 = 0.250 total
0.050 : 0.2501 : 5
-
CLS 414 Clinical Chemistry Student Lab Rotation: Basic Principles of Electrophoresis Lecture 8
Technical Considerations
Evaporation and wick flow
43
Electroendosmosis
Electroendosmosis Surface of gel is negatively charged Surface gel ions are immobile Positive buffer ions (pH 8.6) orient with
negative surface ions = positive ionic cloud
44
negative surface ions positive ionic cloud
Electroendosmosis Ionic cloud is mobile Electrical current causes positive ionic cloud to
move toward the cathode
45
Electroendosmosis Molecules on surface of gel that hold a weak
negative charge are pushed toward the cathode despite migration direction toward the anode
46
Electroendosmosis Macromolecules (proteins) that have a sufficiently
strong enough charge are able to oppose the flow of the positive ion cloud and move in the oppositedirection towards the electrode of opposite polarity
47
Types of Electrophoresis
Agarose, cellulose, polyacrylamide Iso-electric focusing Counter-current electrophoresis
48
Two-dimensional electrophoresis High resolution electrophoresis Capillary electrophoresis
-
CLS 414 Clinical Chemistry Student Lab Rotation: Basic Principles of Electrophoresis Lecture 9
Blotting Techniques
General procedure Separation by electrophoresis Separated components transferred (blotted)
to a specific membrane (nylon cellulose gel)
49
to a specific membrane (nylon, cellulose, gel) Detected using nucleic acid probe
Southern blot: DNA, DNA fragments Northern blot: RNA, RNA fragments Western blot: viral antibodies (HIV-1)
Electrophoresis is a technique used inclinical laboratories to separate particles(proteins) from each other: Proteins in body fluids: serum, urine, CSF Proteins in erythrocytes: hemoglobin
50
Nucleic acids: DNA, RNA