Electronic DC Load - DC Power Supplies · Electronic DC Load The ELA 250 Series loads are...

4
CP Power & Automation Ltd 8 Hotchkiss Way, Coventry, CV3 2RL, UK Tel: + 44 (0)2476 444845, Fax: + 44 (0)2476 561531, Web: www.cppowerautomation.com EMC: Input EMI filter EN61000-6-3 Input immunity EN61000-6-1 Control, operation and instruments: Manual adjust current and resistance 2 set values each (A and B) for 2 channels selectable with a score and fine potentiometer each per channel Pulse-generator I, R 100Hz or 1kHz switch-selected, waveform: square-wave, duty cycle 1:1 Load ON/OFF-function load to be switched at high Ohm state Instruments load current, load voltage: LED digital load current 3-digits load voltage 75V: 3-digits load voltage 160V: 3.5-digits accuracy: 0.2% ±1d Disturbance indication LED red: over temperature or over voltage LED yellow: current limitation or over load Parallel operation same units possible Programming Interface (Remote Control Port): jack RJ45 ext. voltage 0 - 10V = 0 - I max any waveform, frequency range: (-3dB): 0 - 6kHz accuracy: 0.2% I max Load ON/OFF function Load to be switched at high Ohm state Monitor signal Load current, load voltage accuracy 0.2% I max , U max Disturbance signal composit failure (active low) (OR-link at following failures: over temperature, over voltage, over load, current limitation) Input: Input voltage 230VAC -10% +6%, 50-60Hz Load voltage see table Load current see table Continuous Power 250W Regulation: Set point accuracy 0,1% I max (Voltage change + 20%) Rise time (at 10-90% nominal value change I-Mode) ELA250/75/20, ELA250/75/40 U L > 3V 60μs U L < 3V 400μs ELA250/160/20 U L > 6V 60μs U L < 6V 400μs Temperature coefficient 0.01%/°C (after 15 min. working time, const. T ambient. and U input ) Protection: Overload protection power limit, short circuit protection Overvoltage protection power shutdown U max +6% Thermal protection power shutdown, auto recovery Reverse polarity wattless current diode and fuse Environmental Condition: Operating temperature 0 - +40°C Cooling int. fans, temperature controlled Safety: Safety standard EN 61010 Isolation AC input - load input 2.3kV eff AC input - ground 1.35kV eff Load input - ground U L 75V: 500V eff U L = 160V: 1kV eff Series ELA Power 250 Watt Constant I-Mode or G-Mode Master-Slave Mode Ext. programmable current const. ext. programmable I-constant ext. programmable I-,P- or G- constant with a G-Module installed Options : Installed IEEE488.2 (GPIB) / RS232 interface with Lab-View Driver (Series INT2E) Installed USB Interface with driver software External CAN Open Interface (on request) G- Module Electronic DC Load The ELA 250 Series loads are electronically regulated DC loads with power up to 250Watt. They are designed with the latest MOS technology and a DC load range starting at 0.35VDC up to 160VDC. Anyywhere DC loads are needed as a stand alone type or integrated via interface in system applications, the ELA 250 series offers intelligent features such as: Minimum load voltage 0.35VDC / Load ON/OFF / Remote Control Port (RCP) with additional 0.15VDC voltage to supply external components / Local-Lockout / U- and I-Monitor outputs buffered / Load-On-Relay at Power-Up / etc

Transcript of Electronic DC Load - DC Power Supplies · Electronic DC Load The ELA 250 Series loads are...

Page 1: Electronic DC Load - DC Power Supplies · Electronic DC Load The ELA 250 Series loads are electronically regulated DC loads with power up to 250Watt. They are designed with the latest

CP Power & Automation Ltd 8 Hotchkiss Way, Coventry, CV3 2RL, UK Tel: + 44 (0)2476 444845, Fax: + 44 (0)2476 561531, Web: www.cppowerautomation.com

EMC:Input EMI filter EN61000-6-3Input immunity EN61000-6-1

Control, operation and instruments:Manual adjust current and resistance 2 set

values each (A and B)for 2 channels selectable witha score and fine potentiometereach per channel

Pulse-generator I, R 100Hz or 1kHz switch-selected,waveform: square-wave, dutycycle 1:1

Load ON/OFF-function load to be switched at highOhm state

Instruments load current, load voltage:LED digitalload current 3-digitsload voltage ≤ 75V: 3-digitsload voltage 160V: 3.5-digitsaccuracy: 0.2% ±1d

Disturbance indication LED red: over temperature orover voltageLED yellow: current limitationor over load

Parallel operation same units possible

Programming Interface (Remote Control Port):jack RJ45ext. voltage 0 - 10V = 0 - Imaxany waveform,frequency range: (-3dB): 0 - 6kHzaccuracy: 0.2% Imax

Load ON/OFF function Load to be switched at highOhm state

Monitor signal Load current, load voltageaccuracy 0.2% Imax , Umax

Disturbance signal composit failure (active low)(OR-link at following failures:over temperature,over voltage, over load,current limitation)

Input:Input voltage 230VAC -10% +6%, 50-60HzLoad voltage see tableLoad current see tableContinuous Power 250W

Regulation:Set point accuracy ≤ 0,1% Imax(Voltage change + 20%)Rise time (at 10-90%nominal value change I-Mode)ELA250/75/20, ELA250/75/40 UL > 3V ≤ 60µs

UL < 3V ≤ 400µsELA250/160/20 UL > 6V ≤ 60µs

UL < 6V ≤ 400µsTemperature coefficient ≤ 0.01%/°C(after 15 min. working time,const. Tambient. and Uinput)

Protection:Overload protection power limit, short circuit

protectionOvervoltage protection power shutdown Umax +6%Thermal protection power shutdown, auto

recoveryReverse polarity wattless current diode and

fuse

Environmental Condition:Operating temperature 0 - +40°CCooling int. fans, temperature

controlled

Safety:Safety standard EN 61010IsolationAC input - load input 2.3kVeffAC input - ground 1.35kVeffLoad input - ground UL ≤ 75V: 500Veff

UL = 160V: 1kVeff

Series ELAPower 250 Watt

Constant I-Mode or G-ModeMaster-Slave ModeExt. programmable current const.

ext. programmable I-constantext. programmable I-,P- or G- constantwith a G-Module installed

Options :Installed IEEE488.2 (GPIB) / RS232 interface withLab-View Driver (Series INT2E)Installed USB Interface with driver softwareExternal CAN Open Interface (on request)G- Module

Electronic DC Load

The ELA 250 Series loads are electronically regulated DC loads with power up to 250Watt. They are designed with the latest MOStechnology and a DC load range starting at 0.35VDC up to 160VDC.Anyywhere DC loads are needed as a stand alone type or integrated via interface in system applications, the ELA 250series offers intelligent features such as:Minimum load voltage 0.35VDC / Load ON/OFF / Remote Control Port (RCP) with additional 0.15VDC voltage to supplyexternal components / Local-Lockout / U- and I-Monitor outputs buffered / Load-On-Relay at Power-Up / etc

Page 2: Electronic DC Load - DC Power Supplies · Electronic DC Load The ELA 250 Series loads are electronically regulated DC loads with power up to 250Watt. They are designed with the latest

4/9zentro-elektrik GmbH KG / Tel.: +49 (0)72 31 - 4 52 03 / Fax: +49 (0)72 31 - 46 42 05 / Internet: www.zentro-elektrik.de

AC

/DC

und

DC

/DC

Sys

tem

e

CP Power & Automation Ltd 8 Hotchkiss Way, Coventry, CV3 2RL, UK Tel: + 44 (0)2476 444845, Fax: + 44 (0)2476 561531, Web: www.cppowerautomation.com

Pin assignment RCP-Interface (Remote Control Port):

Electrical Connections:Input voltage Euro-plug with switch,

rear sideLoad jack 4mmØ

Dimensions and weight:Dimensionswxhxd without option INT2E:

70x220x340mmwith option INT2E:95x220x340mm

Weight 4kg

Option G-Module:Programming 2 set values each at I-, P-, G-

Modeext. voltage 0 - 10V = 0 - Imaxext. voltage 0 - 10V = 0 - Pmaxext. voltage 0 - 10V = 0 - Gmax

Load ON/OFF function Load to be switched at highOhm state

Pulse generator I, G 100Hz or 1kHz to be switched,waveform: square-wave,duty cycle 1:1

Feed back signal load current, load voltage(0 -10V)accuracy: 0.2% Imax, Umax

Disturbance signals signal: composit failure(active low)signal: over temperature,over voltagesignal: over load, currentlimitationsignal: under voltage

Lead for programming 25 pol. Sub D jack

Option INT2E:Programming 2 set values each at I-, P-,

G-Mode with G-module, 1 setvalue at I-Mode without G-moduleresolution : 12Bit(4000 steps per range)accuracy: 0.25% Imax (I-Mode)

Feed back signal load current, load voltageresolution: 12 Bit (Imax/4000;Umax/4000)accuracy: 0.25% Imax, Umax

Load ON/OFF function load to be switched at highOhm state

Function Local Lockout in remote mode the operationinstruments at the front panelare inactive

Disturbance signal signal: composit failuresignal: over temperature,over voltagesignal: over load,current limitationsignal: under voltage

Connectors 9 pole Sub D conncetor (RS232)24 pole IEEE488/GPIB-jackUSB-jack type B

ouptut- DC load- Load- Load - Model-pow er voltage current resistance Number

(W) (V) (A) (Ohm)250 0.35 - 75 0 - 20 0.05 - 15 k ELA250/75/20250 0.35 - 75 0 - 40 0.04 - 7.5 k ELA250/75/40250 0.35 - 160 0 - 20 0.05 - 32 k ELA250/160/20

RCP SIGNAL(RJ45)Pin 8 Analog-GNDPin 7 Control Voltage 0-10VPin 6 Actual value load current 0-10VPin 5 Actual value load voltage 0-10VPin 4 Signal composit failurePin 3 Instruction Load ON/OFFPin 2 Digital-GNDPin 1 Auxiliary voltage +15V (max. 20mA load capacity)

Options:- Sub front panel

colour AL nature anodizedELA 250 without INT2E:6HE, 16TEELA 250 with INT2E: 6HE, 19TE

- Front-End unit without operation instruments- USB interface with driver software *- CAN Open interface (on request)- G-Module- Sub D connector for ELA 250 (with option G-moduleat ELA 250 …: Sub D connector is a standard)

- Integrated Interface IEEE488.2 (GPIB)INT2E with Lab-View driver

- Cable for external stand alone- interface INT2

* RS232 or USB selectable

GPIB - USB - CAN - BUS

Page 3: Electronic DC Load - DC Power Supplies · Electronic DC Load The ELA 250 Series loads are electronically regulated DC loads with power up to 250Watt. They are designed with the latest

CP Power & Automation Ltd 8 Hotchkiss Way, Coventry, CV3 2RL, UK Tel: + 44 (0)2476 444845, Fax: + 44 (0)2476 561531, Web: www.cppowerautomation.com

0,1

1

10

100

1000

1 10 100Load Current [A]

Lo

ad V

olt

age

[V]

160V

75V

20A

40A

0,00A

5,00A

10,00A

15,00A

20,00A

25,00A

30,00A

35,00A

40,00A

45,00A

0,20V 0,40V 0,60V 0,80V 1,00V 1,20V 1,40V 1,60V 1,80V 2,00V

Load Voltage [V]

Lo

ad C

urr

ent [

A]

ELA250-20A

ELA250-40A

Minimum Voltage ELA250:

Operating Range ELA250

Electronic DC Load

Page 4: Electronic DC Load - DC Power Supplies · Electronic DC Load The ELA 250 Series loads are electronically regulated DC loads with power up to 250Watt. They are designed with the latest

4/11zentro-elektrik GmbH KG / Tel.: +49 (0)72 31 - 4 52 03 / Fax: +49 (0)72 31 - 46 42 05 / Internet: www.zentro-elektrik.de

AC

/DC

und

DC

/DC

Sys

tem

e

CP Power & Automation Ltd 8 Hotchkiss Way, Coventry, CV3 2RL, UK Tel: + 44 (0)2476 444845, Fax: + 44 (0)2476 561531, Web: www.cppowerautomation.com

ELA 250 Watt:

ELA 250 Watt with Interface:

digital instruments, LED

overload and currentlimitation, LED yellow

over temperature andover voltage, LED red

int. pulse operation100 Hz, 1kHz

chanel Achanel Bint. pulse operation A

B

mode switch

load ON/OFF

set value chanel Acoarse / fine

set value chanel Bcoarse / fine

load connector

fans, temperature controled

remote control portRJ45 jack

additionale module(G-module) jack(option)

mains connector withfuse and switch

interface status indicationLED red and yellow

IEEE488.2 (GPIB)25 pole jack

switches forinterface configuration

RS2329 pole SUBD connector *

USB jacktype B *

* RS232 or USB selectable