THESIS PROGRAM is according to directives: -Eco-design Directive for Energy-using Products, 2005/32/EC (<0,5W). EN 62233:2008 EN 55014-1:2006 + A1:2009 + A2:2011 EN 55014-2:1997 + A1:2001 + IS1:2007 + A2:2008 ===> Cat. 2 EN 61000-3-2:2014 EN 61000-3-3:201 -Eco-design Directive for Energy-using Products, 2005/32/EC (<0,5W). Disponible Colors: - White - Chrome THESIS PROGRAM is a digital chronothermostat for the control of electric towel warmers. Thanks to an external sensor it is able to maintain the desired room temperature. THESIS PROGRAM has a simple and modern design, suitable for any type of furniture and type of towel warmer. THESIS PROGRAM is installed simply and is available in different colors. THESIS PROGRAM is a certified product. Selmo Electronic Via Pacinotti, 24 - 35030 Rubano www.selmo.it (PD) Italy- Tel 049.8976761, Fax 049.8976085 - Selmo Electronic Via Pacinotti, 24 - 35030 Rubano www.selmo.it “Thesis Program” Electronic Control for Towel Heaters ITA Comfort technology division Selmo Revision Beta - June 2018

Transcript of Electronic Control for Towel Heaters1. Make sure the towel warmer has no leakage or pockets of air...

Page 1: Electronic Control for Towel Heaters1. Make sure the towel warmer has no leakage or pockets of air inside. 2. The appliance must not be placed directly in front of a power outlet.

THESIS PROGRAM is according to directives:

-Eco-design Directive for Energy-using Products, 2005/32/EC (<0,5W).EN 62233:2008EN 55014-1:2006 + A1:2009 + A2:2011EN 55014-2:1997 + A1:2001 + IS1:2007 + A2:2008 ===> Cat. 2EN 61000-3-2:2014EN 61000-3-3:201

-Eco-design Directive for Energy-using Products, 2005/32/EC (<0,5W).

Disponible Colors: - White- Chrome

THESIS PROGRAM is a digitalchronothermostat for the controlof electric towel warmers. Thanksto an external sensor it is able tomaintain the desired roomtemperature.THESIS PROGRAM has asimple and modern design,suitable for any type of furnitureand type of towel warmer.

THESIS PROGRAM is installedsimply and is available in differentcolors.THESIS PROGRAM is a certifiedproduct.

Selmo Electronic

Via Pacinotti, 24 - 35030 Rubano www.selmo.it(PD) Italy- Tel 049.8976761, Fax 049.8976085 -

Selmo Electronic

Via Pacinotti, 24 - 35030 Rubano www.selmo.it

“Thesis Program”Electronic Control for Towel Heaters

ITA

Comfort technology divisionSelmo

Revision Beta - June 2018

Page 2: Electronic Control for Towel Heaters1. Make sure the towel warmer has no leakage or pockets of air inside. 2. The appliance must not be placed directly in front of a power outlet.

Presentation• Operating modes: Comfort, Night,Antifreeze, Fil-Pilote, Chrono, Timer 2h,Stand-by.

- In "Comfort" mode:The electronic control maintains the ambient temperature at the value set by the user.

- In "Night" mode:The electronic control maintains the ambient temperature at a reduced value comparedat the "Comfort" temperature.

- In "Antifreeze" mode:The electronic control maintains the ambient temperature above 7 ° C.

- In "Fil-Pilote" mode:The operation of the electronic control is decided by the signal sent by the system"Fil-Pilote".

- In "2h timer" mode:The electronic control activates the heating element for two hours regardless of the settemperature.At the end of this period the thermostat returns to the previously setoperating mode. During the two hours, for safety reasons, the ambient temperature willbe adjusted to not exceed 32 ° C.

- In "Chrono" mode:The electronic control works according to a weekly repetition program, the program canbe set by the user.

-In "Stand-by":The heating element is deactivated but the electronic control remains active.

• Other informations:• Large backlit display, with the display of the set temperature,

now, programming and the mode / function set.•All modes / functions can be set using the IR remote control (optional).• Daily and weekly program set by the user according to his ownneeds.• Fuction "Open window detection": if this function is activated, deactivates the elementheating of the heated towel rail at the opening of the room window, for a maximum30 minutes, thus bringing energy savings.

Selmo Electronic

Via Pacinotti, 24 - 35030 Rubano www.selmo.it(PD) Italy- Tel 049.8976761, Fax 049.8976085 -

Selmo Electronic

Via Pacinotti, 24 - 35030 Rubano www.selmo.it

“Thesis Program”Electronic Control for Towel Heaters

ITA

Comfort technology divisionSelmo

Revision Beta - June 2018

Page 3: Electronic Control for Towel Heaters1. Make sure the towel warmer has no leakage or pockets of air inside. 2. The appliance must not be placed directly in front of a power outlet.

Product

Applications

Version

IP

Ambient Temperature setting

Display

Functions

Settable temperature range

Operating temperature range

Maximum Power

Alimentation

Dimensions

Enviornmental Temperature Sensor

Warranty

Normatives

Approvation Mark

Directives

Digital Control for Towel Heaters

Towel Heaters

Class I Class II

IP44

Disponible only on class II

Digital With Keys

Temperature, date & hour, mode/functions,warming indicator, Keys Lock, Backlight.

Comfort, Night, Antifreeze, Stand-by, Fil-Pilote, Timer 2h,Chrono, Open Window Relevation, ASC

7°C ÷ 32°C

-10°C ÷ +40°C

2000W

230VAC 50Hz - 60Hz

113 x 73 x 39mm (H x Lx l)

Faston 6.3x0.8mm phase, neutral, Ground (only on class I)

10KOhm at 25°C, NTC probe

2 years

EN 62233:2008EN 55014-1:2006 + A1:2009 + A2:2011EN 55014-2:1997 + A1:2001 + IS1:2007 + A2:2008EN 61000-3-2:2014EN 61000-3-3:201

CE

WEEE, RoHS

Technical Carachters

Fil-Pilote

Heating Element Connection

NoteRepairs: Must be carried out by an authorized service center.Compatibility with other products: Contact your supplier.Warranty: 2 years warranty from the date of purchase.The warranty does not cover the following cases:- Products that are tampered with or damaged by the customer;- Products that have been installed or used by the customer in a manner inconsistent with what is specified in this manual;- Products that have been modified by the customer

Selmo Electronic

Via Pacinotti, 24 - 35030 Rubano www.selmo.it(PD) Italy- Tel 049.8976761, Fax 049.8976085 -

Selmo Electronic

Via Pacinotti, 24 - 35030 Rubano www.selmo.it

“Thesis Program”Electronic Control for Towel Heaters

ITA

Comfort technology divisionSelmo

Revision Beta - June 2018

Page 4: Electronic Control for Towel Heaters1. Make sure the towel warmer has no leakage or pockets of air inside. 2. The appliance must not be placed directly in front of a power outlet.

E CLECTRICAL ONNECTIONSThe available versions are as follows:• 1 Schuko plug, Switzerland, English, Italian (class I or class II) for direct connection.• 3 wires for the class I models: phase (brown), neutral (blue), earth (green-yellow).• 2 wires for the class II models: phase (brown), neutral (blue).• 3 wires for the class II models with "Fil-Pilote": phase (brown), neutral (gray), "Fil-Pilote" (black).

Caution.Danger of electric shock.

Disconnect the power supply before installation.

Keep this instruction sheet carefully and read it carefully before using this device.

• This device has been designed exclusively for use on towel warmers.

• This thermostat is used to heat the liquid contained in a heated towel rail in combination with aheating element. Any other use is prohibited.

• Before use, check that the mains voltage is the same as that of the thermostat (see technicalspecifications).

• Use only suitable heating elements for the type of towel warmer used.

• Disconnect the power supply before cleaning or maintenance.

• In case of damage to the power cord, switch the device off and do not tamper with it. Damagedpower cables can only be replaced by the manufacturer or an authorized service center. Failure tocomply with the above can compromise system security and void the warranty.

• Store and transport the heating element only in protective packaging.

• Replacement of the heating element can only be performed by the manufacturer.

• The appliance can be used by children aged 8 or less and by persons with reduced physical,sensory or mental abilities, provided they are under surveillance. Children must not play with theappliance.

• Cleaning and maintenance intended for use by the user must not be carried out by children withoutsupervision.

Selmo Electronic

Via Pacinotti, 24 - 35030 Rubano www.selmo.it(PD) Italy- Tel 049.8976761, Fax 049.8976085 -

Selmo Electronic

Via Pacinotti, 24 - 35030 Rubano www.selmo.it

“Thesis Program”Electronic Control for Towel Heaters

ITA

Comfort technology divisionSelmo

Revision Beta - June 2018

Page 5: Electronic Control for Towel Heaters1. Make sure the towel warmer has no leakage or pockets of air inside. 2. The appliance must not be placed directly in front of a power outlet.

Installation InstructionsInstaller’s Use only

• The electronic thermostat must be connected to the resistor only by personnelauthorized.

• Make sure that the heating element power does not exceed the power

CAUTION:Disconnect the power supply before installation.The installation must be performed by authorized operators.

CAUTION:Disconnect the power supply before installation.The installation must be performed by authorized operators.

NO

YES

Insulator

2 faston connectors 6.3x0.8mm

Thread

Fixing Area

IMPORTANT: pay attention to themaximum length of the connectors(19 mm, see figure above). In caseof longer connectors, the thermostatcould be damaged

Example of heating element

Thread 1/2'' G

O-ring

0,5

67,5 4 3

25

Max 19mm

1,25 45°

N°2 Male Connectors6.38x08 mm

23 18

23

0.5

+

Electronic Control Fixing Area

Selmo Electronic

Via Pacinotti, 24 - 35030 Rubano www.selmo.it(PD) Italy- Tel 049.8976761, Fax 049.8976085 -

Selmo Electronic

Via Pacinotti, 24 - 35030 Rubano www.selmo.it

“Thesis Program”Electronic Control for Towel Heaters

ITA

Comfort technology divisionSelmo

Revision Beta - June 2018

Page 6: Electronic Control for Towel Heaters1. Make sure the towel warmer has no leakage or pockets of air inside. 2. The appliance must not be placed directly in front of a power outlet.

DISPOSALThis appliance is not an ordinary domestic waste. It must be disposed of in the appropriate collection

centers. In case of replacement, it can be returned to the distributor.This end-of-life treatment of the product will allow us to preserve the environment and reduce the

consumption of natural resources.This symbol applied on the product, indicates the obligation to deliver it in the appropriate collection

centers to be disposed of in compliance with the directive 2002/96 / CE (WEEE).

1. Make sure the towel warmer has no leakage or pockets of air inside.2. The appliance must not be placed directly in front of a power outlet.3. Avoid the appliance being hit by jets of water.4. Connect the temperature regulator only to a suitable heating element.5. Check that the mains voltage is the same as indicated in the technical specifications.6. Make sure that the type of resistance is approved for the type of towel warmer used

(see manufacturer's documentation). Use of a heating element with a greater onepower:

- Does not increase the effective power of the towel warmer;- May cause premature destruction of the heating element;- It may damage the equipment.7. Make sure that the resistance power does not exceed the maximum heating capacity of the heater.

viette (see plate on the heating element).8. When installed in rooms with bath or shower, observe the protection zones for

the IP44 insulation class (in the United Kingdom according to the IEE wiring regulations).Also, observe all local regulations.

9. It must be protected by a 30mA differential switch (RCD).10. Supply the device with the required voltage (see technical specifications).11. If a device is connected directly to the fixed electrical systems, install a disconnector

in accordance with local provisions for disconnection from the electricity grid.12. Position the appropriate "O-ring" before the fixing area13. After making sure that the "O-Ring" is well positioned, screw the resistance into the appropriate one

threaded hole in towel warmer, tighten properly and insert cover ring.14. Remove the connection cables from the thermostat. The two faston connectors and the groundconnector

for class I.15. Insert the 2 fastons into the relative connectors of the heating element.16. Insert the female faston of the ground connection (class I only).17. Insert the lower part of the heating element into the thermostat that has just been connected.18. Align the electronic thermostat with the towel warmer. Warning! Do not rotate the thermostat

over 30 degrees in both directions.19. Press the thermostat against the base of the heating element to compress the "O-Ring",

adequately tighten the appropriate screw so that the thermostat remains firmly fixed and notrotate around the heating element.

20. Connect the power cord to the mains.

• Disconnect the power supply before installation.• The electronic thermostat must be connected to the heating element by qualified personnel.• Ensure that the resistance power does not exceed the maximum power allowed by the controlelectronic

Selmo Electronic

Via Pacinotti, 24 - 35030 Rubano www.selmo.it(PD) Italy- Tel 049.8976761, Fax 049.8976085 -

Selmo Electronic

Via Pacinotti, 24 - 35030 Rubano www.selmo.it

“Thesis Program”Electronic Control for Towel Heaters

ITA

Comfort technology divisionSelmo

Revision Beta - June 2018

Page 7: Electronic Control for Towel Heaters1. Make sure the towel warmer has no leakage or pockets of air inside. 2. The appliance must not be placed directly in front of a power outlet.

1.Thesis Program with "Fil-Pilote" function (class II) can be controlled remotely by acontrol unit that supports the "Fil-Pilote" system. The brown wire is the phase (L), thegray wire is the neutral (N) and the black wire is used for the reception of the Fil-Pilotesignal.

Do not connect the black wire to the ground.

2.Thesis Program without "Fil-Pilote" function (class I), can not be controlled remotely.The brown wire is the phase (L), the blue wire is the neutral (N) and the yellow / greenwire must be connected to the ground.

Fil-Pilote System Connection(Only for "Fil-Pilote" versions)

Example

1

PHASE NEUTRAL

Living room Bathroom Bedroom1 Bedroom2

Thermostatclass II

Thermostatclass II

Thermostatclass II

Thermostatclass I

Switch

Stazione"Fil-Pilote"

Switch

Switch Switch

Thermostat ThermostatThermostat Thermostat

"Fil-Pilote"

230 Vac50 Hz

Selmo Electronic

Via Pacinotti, 24 - 35030 Rubano www.selmo.it(PD) Italy- Tel 049.8976761, Fax 049.8976085 -

Selmo Electronic

Via Pacinotti, 24 - 35030 Rubano www.selmo.it

“Thesis Program”Electronic Control for Towel Heaters

ITA

Comfort technology divisionSelmo

Revision Beta - June 2018

Page 8: Electronic Control for Towel Heaters1. Make sure the towel warmer has no leakage or pockets of air inside. 2. The appliance must not be placed directly in front of a power outlet.

User’s Manual

LCD Display

Key[-]

Key [Chrono]

Key [+]

Key [Mode]

Key [Stand-By/ON]

Alimentation CableNTC Probe

Selmo Electronic

Via Pacinotti, 24 - 35030 Rubano www.selmo.it(PD) Italy- Tel 049.8976761, Fax 049.8976085 -

Selmo Electronic

Via Pacinotti, 24 - 35030 Rubano www.selmo.it

“Thesis Program”Electronic Control for Towel Heaters

ITA

Comfort technology divisionSelmo

Revision Beta - June 2018

Page 9: Electronic Control for Towel Heaters1. Make sure the towel warmer has no leakage or pockets of air inside. 2. The appliance must not be placed directly in front of a power outlet.

1. / S -INGINTON TAND BY

Press the key to turn on the unit or activate the "Stand-by" mode.[On / Stand-by]When active, the lower area of the display shows the current time, at the top the set mode and the temperature are

displayed. During "Stand-by" the display shows the word "Stb", the current time and the day of the week.NOTE: When the device enters "Stand-by" mode, 2 sounds of 0.5 seconds are emitted.

When the device is switched on, it emits a sound lasting one second.

2. MOD CO FORTE M IGHT& N :Two different temperature levels can be set:

- "COMFORT" TEMPERATURE: this is the temperature used for the "Chrono", "Fil-Pilote" and "Comfort" modes.

this is the temperature used for "Night" and "Chrono" modes.- "NIGHT" TEMPERATURE:The desired temperature setting can be set by pressing the and buttons.[+] [-]The temperature regulation range is between 7 ° C and 32 ° C.

IMPORTANT!The "Night" temperature is always lower than the "Comfort" temperature and the priority is assigned to the

"Comfort" temperature. For this reason the "Night" temperature can be set in the range 7 ° C ÷ ("Comfort" - 0.5 ° C),

on the contrary the "Comfort" temperature can be set within the entire range: ("Night" + 0 , 5 ° C) to 32 ° C.

Setted Temperature

Clock

Keys lock icon

Current weekly day

Comfort/Night statusChrono mode

Function mode Icons-Fil-Pilote;-Comfort;-Night;-Antifreeze;-Timer 2h;-Chrono;-Stand-By;

Active HeatingElement

‘’Open WindowRelevation’’Function.

"ASC" Icon.

Child Protection

Selmo Electronic

Via Pacinotti, 24 - 35030 Rubano www.selmo.it(PD) Italy- Tel 049.8976761, Fax 049.8976085 -

Selmo Electronic

Via Pacinotti, 24 - 35030 Rubano www.selmo.it

“Thesis Program”Electronic Control for Towel Heaters

ITA

Comfort technology divisionSelmo

Revision Beta - June 2018

Page 10: Electronic Control for Towel Heaters1. Make sure the towel warmer has no leakage or pockets of air inside. 2. The appliance must not be placed directly in front of a power outlet.

3. O MPERATIVE ODEPress the button to select the desired mode (see table below).[Mode]

CO FORTM MODEThe "Comfort" mode allows maintaining the set room temperature.To set this mode:- Press the button until the "Comfort" mode icon appears on the display.[Mode]- Set the desired temperature with the and buttons.[+] [-]

NIGHT MODEIn "Night" mode, a temperature lower than the "Comfort" temperature is set.We recommend using this mode at night or when the room is not used for 2 hours or more.- Press the button until the "Night" icon appears on the display.[Mode]- Set the desired temperature with the and buttons[+] [-]

ANTIFREEZE MODEIn the "Antifreeze" mode the temperature is set at 7 ° C. The appliance activates the heating element when the roomtemperature drops below 7 ° C. We recommend using this mode when the room is not used for several days.- Press the button until the "Antifreeze" icon appears on the display[Mode]

T 2IMER H MODEThe "2h Timer" mode can be used to quickly heat the room or speed up the drying of the wipes.- Press the button until the "2h" icon appears on the display.[Mode]The appliance is switched on at maximum power for 2 hours, up to a temperature of 32 ° C. The "2h Timer" mode is set toautomatically stop after a period of 2 hours and return to the previously set operating mode. If necessary, the user can return toother modes at any time by simply pressing the button.[Mode]

FIL PILOTE ODE- M(Only for models equipped with "Fil-Pilote" connection).In "Fil-Pilote" mode the appliance is managed by a central system, which sets the operating mode for all connected thermostats.The device also recognizes the most advanced "Fil-Pilote" system with six orders that allows the use of the functions describedbelow.1. : switch off the heating element, the thermostat remains on.Standby2. maintains the "Comfort" temperature set by the user.Comfort:3. : maintains the ambient temperature lower than 3.5 ° C compared to the "Comfort" temperature.Eco4. maintains the ambient temperature at 7 ° C.Anti-freeze (antifreeze):5. maintains the ambient temperature lower than 1 ° C with respect to the "Comfort" temperature.Eco-1:6. maintains the ambient temperature lower than 2 ° C with respect to the "Comfort" temperature.Eco-2:

To activate the "Fil-Pilote" function:- Press the button until the "Fil-Pilote" mode icon appears on the display.[Mode]- Set the desired temperature with the and buttons.[+] [-]If the "Fil-Pilote" system is not installed, the system operates in "Comfort" mode.

Fil-Pilote Comfort Night Antifreeze Timer 2H Chrono

Selmo Electronic

Via Pacinotti, 24 - 35030 Rubano www.selmo.it(PD) Italy- Tel 049.8976761, Fax 049.8976085 -

Selmo Electronic

Via Pacinotti, 24 - 35030 Rubano www.selmo.it

“Thesis Program”Electronic Control for Towel Heaters

ITA

Comfort technology divisionSelmo

Revision Beta - June 2018

Page 11: Electronic Control for Towel Heaters1. Make sure the towel warmer has no leakage or pockets of air inside. 2. The appliance must not be placed directly in front of a power outlet.

MODALITÀ RONOCThis mode of operation allows the user to set different temperatures during the day.The "Comfort" / "Night" temperature and the time intervals can be programmed.-To activate the function, press the key until the "Chrono" icon appears on the display.[Mode]

Programming the Chrono modea) Set the current day and time- Activate the "Stand-by" mode and press the button for more than 3 seconds.[-]- At the top of the display the following message will be displayed: "Set" (Setting)- To set the current day and time, press the key until in the part[+]the display shows the word TED (time and date).[See the photo on the right]

- Press the button to enter the mode.[Mode]- The flashing arrow indicates the current day: with the keys

and set the current day.[+] [-]- Press the button again to confirm.[Mode]Now the display shows the current time to be set.'Hours': use the and keys to set the time and confirm with the key.[+] [-] [Mode]'Minutes': repeat the same procedure and confirm with the key.[Mode]

- At the end the thermostat returns to "Stand-by" mode.

b) Set the program for the Chrono mode:- Enter "Stand-by" mode and press the button for more than 3 seconds.[-]- At the top of the display the following message will be displayed: "Set" (Setting)- To set the time sequence of the "Chrono" mode, press the key until[+]at which the word Prog (Programming) appears at the bottom of the display.[See the photo on the right]

- Press the button to enter the mode.[Mode]Now a time sequence can be set for each day of the week.Starting with day 1, select the desired sequence with the keys and[+] [-]to select, for each hour, between the "Comfort" temperature (solid bar) button [+]and the "Night" temperature (empty bar) key.[-]See photos below as a reference.Press to confirm the setting for the first day,[Mode]repeat the same procedure for the remaining 6 days of the week.

Selmo Electronic

Via Pacinotti, 24 - 35030 Rubano www.selmo.it(PD) Italy- Tel 049.8976761, Fax 049.8976085 -

Selmo Electronic

Via Pacinotti, 24 - 35030 Rubano www.selmo.it

“Thesis Program”Electronic Control for Towel Heaters

ITA

Comfort technology divisionSelmo

Revision Beta - June 2018

Page 12: Electronic Control for Towel Heaters1. Make sure the towel warmer has no leakage or pockets of air inside. 2. The appliance must not be placed directly in front of a power outlet.

4. K L FEYS OCK UNCTIONYou can lock the keyboard to prevent accidental changes.Press the button for 3 seconds to lock the keyboard except[Mode]of the key. The "Key lock" icon appears on the display.[On / Stand-by]To unlock the keyboard, press the button for 3 seconds, the lock icon[Mode]keys disappear from the display.

6 O W R F. PEN INDOW ELEVATION UNCTIONThe "Open window detection" function allows the device to detect if the room window is opened by a sudden drop intemperature. In this case, the device deactivates the heating element for up to 30 minutes. When the 30 minutes haveelapsed or if the room temperature increases, the thermostat is reactivated.To activate this function:-Activate the "Stand-by" mode.- Press the button for 3 seconds.[+]-Press the button to turn the function on or off.[+]-Press the key to confirm and return to "Stand-by" mode.[Prog]When the function is activated, the "open window" symbol remains lit.When the device detects the open window, the symbol flashes.When the function is deactivated, the symbol disappears.Note: the device may not detect the window opening.This can happen when: the thermostat is in an isolated place away from drafts or near a source of heat outside the device orthe change in room temperature is too slow.

N.B. 1: when the symbol " " is on, the heating element is active.

in case of mains failure, the thermostat configuration remains in memory forN.B. 2:5 minutes.

The manufacturer reserves the right to make changes at any time as deemed necessary toimprove the product without prior notice.

ASC FunctionThis function allows you to optimize the operating times of the device, in order to limit consumption, by activating

this mode the device will record the time necessary to bring a specific room to the set temperature, adjusting its

operation automatically, in this way thermostat can be activated after time setted if is possible to reach the

desired temperature in less time than that foreseen by the operating time intervals that have been set. activate

Stand-by mode, press the key for more than 3 seconds, scroll through the modes with the key and[Crono] [+]

select FUNC with the key, press it until the icon appears on the upper part of the screen, select ON[Prog]with the key and press again to confirm. After a few seconds, the remote control automatically returns[+] [Prog]to Stand-By mode.

Selmo Electronic

Via Pacinotti, 24 - 35030 Rubano www.selmo.it(PD) Italy- Tel 049.8976761, Fax 049.8976085 -

Selmo Electronic

Via Pacinotti, 24 - 35030 Rubano www.selmo.it

“Thesis Program”Electronic Control for Towel Heaters

ITA

Comfort technology divisionSelmo

Revision Beta - June 2018