Electromagnetic Flowmeter / Energy MeterUCL Flow Transducers + UC Converters
Inline FlowmeterUCL2501 / UC880
Inline FlowmeterUCL1000 / UC880
Insertion FlowmeterUCL3770 / UC880
Flange Type Transducer
UCL2501
Wafer Type Transducer
UCL2501
Insertion Type Transducer
UCL2501
Wall Mount Flow Converter
UC880
Compact Type Flow Converter
UC880
Wall Mount Energy Converter
UC880
![Page 3: Electromagnetic Flowmeter / Energy Meter Catalogue Rev2018-07-18.pdf · UCL Series Flowmeter - ver.20171129F (Rev.1.1).cdr Author: SK Created Date: 5/3/2018 1:27:07 PM ...](https://reader034.fdocuments.us/reader034/viewer/2022052019/603292b49a56710863747514/html5/thumbnails/3.jpg)
UCL2501
UCL1000
Introduction Magnetic flowmeters operate on the principle of Faraday's Law of MagneticInduction. It is an ideal method to measure water flow, as its accuracy would not be affected by change in temperature, pressure or fluid properties. There is no pressure loss at all. This results in big savings for customers' energy bills. The only requirement is a minimum
conductivity of 5 µS/cm.
Construction
Each flowmeter consists of a measuring sensor and an electronic converter. Sensor types can be inline orinsertion according to different accuracy requirements and installation constraint. A wide variety of converters are available to suit different applications. All converters are microprocessor based, fully auto-compensated and interference free. Input signal isproportional to induced e.m.f. fromflow sensor (detector head) Advanced communication interface and protocol makes it easy to transmit data to computer systems. In particular, a new version of energy calculator type converter with Modbus communication has been launched. Ithas completely changed the concept offlow monitoring and thermal energymeasurement.
Area of application
* Chiller control in HVAC systems.* Energy billing according to consumption in high rise buildings.* Sewage and waste water treatment plants.* Food and beverage factories.* Chemical and pharmaceutical industries.
About the company We have been serving all industries inthe field of instrumentation and control. Inparticular, flow and energy measurement are our specialty and expertise. We have built up a team of sale andservice staff. We are ready to receive your enquiries, and would like to shareour experience in different applications.
UCL3770
UC 880
Subject to change without prior notice Ver.: 20180502
Electromagnetic Flowmeter
UCL Flow Transducers
Flow Converters
OR OR
UC 321
Energy Converters
![Page 4: Electromagnetic Flowmeter / Energy Meter Catalogue Rev2018-07-18.pdf · UCL Series Flowmeter - ver.20171129F (Rev.1.1).cdr Author: SK Created Date: 5/3/2018 1:27:07 PM ...](https://reader034.fdocuments.us/reader034/viewer/2022052019/603292b49a56710863747514/html5/thumbnails/4.jpg)
Model
Description
Body material
Nominal diameter
Nominal pressure
Process connection
Flanges material
Liquid temperature
Lining material
Electrodes material
DN6...50 (PN 40 standard)
DN65...2000 (PN 16 standard, others on request)
0...80℃ Hard Rubber or PTFE (lining material)
0...120℃ PTFE (lining material)
Stainless steel AISI 316
others on request
Repeatibility
Accuracy
+/-0.1%
+/-0.4% with UC880-A converters+/-0.3% with UC880-S1 converters (option)+/-0.5% with UC321
UCL2501
"Flanged" sensor, the widest selection of diameters.
Carbon steel painted
Stainless steel AISI 304 or AISI 316 (option)
DN 6...2000
Carbon steel
Stainless steel AISI 304 or AISI 316 (option)
DN6 & 8: PFA (no other option)
DN10 to 32: PTFE (no other option)
DN40 or above: Hard Rubber (option PTFE)
others on request
Flange:DIN
others on request
Protection rating
Turndown ratio 10:1
Compact version - IP67
Remote version (max. 20m) - IP68
Subject to change without prior notice Ver.: 20180502
Transducers
![Page 5: Electromagnetic Flowmeter / Energy Meter Catalogue Rev2018-07-18.pdf · UCL Series Flowmeter - ver.20171129F (Rev.1.1).cdr Author: SK Created Date: 5/3/2018 1:27:07 PM ...](https://reader034.fdocuments.us/reader034/viewer/2022052019/603292b49a56710863747514/html5/thumbnails/5.jpg)
Subject to change without prior notice Ver.: 20180502
Dimensions in mmUCL2501
Compact version
� � PN A B
D1 D2 Weight (kg) Compact Remote
6 40 74 265 165 55 42.5 6
10 196 348 248 90 60 7
15 196 350 250 95 65 8
20 196 355 255 105 75 8
25 196 360 260 115 85 9
32 196 376 276 140 100 11
40 200 345 245 150 110 12
50 200 353 253 165 125 13
65 16 200 373 273 185 145 17
80 200 385 285 200 160 17
100 250 408 308 220 180 22
125 250 433 333 250 210 26
150 300 465 365 285 240 36
200 350 518 418 340 295 43
250 450 630 530 405 355 66
300 500 680 580 460 410 76
350 550 735 635 520 470 94
400 600 790 690 580 525 110
450 600 840 740 640 585 130
500 600 893 793 715 650 153
600 600 998 898 840 770 200
700 700 1105 1005 910 840 258
800 800 1215 1115 1025 950 341
900 900 1315 1215 1125 1050 455
1000 1000 1423 1323 1255 1170 528
1200 1200 1610 1510 1485 1390 686
1400 1400 1770 1670 1685 1590 855
1600 1600 1971 1871 1930 1820 1038
Ť
Remote version
![Page 6: Electromagnetic Flowmeter / Energy Meter Catalogue Rev2018-07-18.pdf · UCL Series Flowmeter - ver.20171129F (Rev.1.1).cdr Author: SK Created Date: 5/3/2018 1:27:07 PM ...](https://reader034.fdocuments.us/reader034/viewer/2022052019/603292b49a56710863747514/html5/thumbnails/6.jpg)
Order code
Subject to change without prior notice Ver.: 20180502
![Page 7: Electromagnetic Flowmeter / Energy Meter Catalogue Rev2018-07-18.pdf · UCL Series Flowmeter - ver.20171129F (Rev.1.1).cdr Author: SK Created Date: 5/3/2018 1:27:07 PM ...](https://reader034.fdocuments.us/reader034/viewer/2022052019/603292b49a56710863747514/html5/thumbnails/7.jpg)
Model UCL1000
Description
Body material
Nominal diameter
Nominal pressure
Process connection
Flanges material
Liquid temperature
Lining material
Electrodes material
"Wafer" sensor, suitable for mounting between mating flanges of various types (UNI, DIN, ANSI, JIS, etc).
Carbon steel painted
Stainless steel AISI 304 or AISI 316 (option)
DN 20...150
DN20...50 (PN 40 standard)
DN65...150 (PN16 standard, other on request)
Wafer type
0...80℃ Hard Rubber or PTFE (lining material)
0...120℃ PTFE (lining material)
No
DN32 or below : PTFE (no other option)
DN40 or above: Hard Rubber (option PTFE)
others on request
Stainless Steel AISI 316
others on request
Compact version - IP67
Remote version (max. 20m) - IP68Protection rating
Repeatibility
Accuracy
+/-0.1%
Turndown ratio 10:1
Subject to change without prior notice Ver.: 20180502
Transducers
+/-0.4% with UC880-A converters+/-0.3% with UC880-S1 converters (option)+/-0.5% with UC321
![Page 8: Electromagnetic Flowmeter / Energy Meter Catalogue Rev2018-07-18.pdf · UCL Series Flowmeter - ver.20171129F (Rev.1.1).cdr Author: SK Created Date: 5/3/2018 1:27:07 PM ...](https://reader034.fdocuments.us/reader034/viewer/2022052019/603292b49a56710863747514/html5/thumbnails/8.jpg)
Subject to change without prior notice Ver.: 20180502
Order code
Dimensions in mmUCL1000
Order code
� � PN A B
Weight (kg) PTFE Hard rubber Compact Remote
20 40 96 100 265 165 5.5
25 96 100 275 175 6
32 96 100 285 190 8
40 96 100 295 200 9.5
50 96 100 310 215 10.5
65 16 146 150 330 235 13
80 146 150 345 250 14
100 146 150 365 270 19
125 176 180 390 285 23
150 176 180 415 285 33
Ť
Compact version
Remote version
![Page 9: Electromagnetic Flowmeter / Energy Meter Catalogue Rev2018-07-18.pdf · UCL Series Flowmeter - ver.20171129F (Rev.1.1).cdr Author: SK Created Date: 5/3/2018 1:27:07 PM ...](https://reader034.fdocuments.us/reader034/viewer/2022052019/603292b49a56710863747514/html5/thumbnails/9.jpg)
Model UCL3770
Insertion sensor, for fixed installationDescription
Probe material
Size for pipe line
Nominal pressure
Process connection
Connection material
Liquid temperature
Lining material
Electrodes material
Stainless steel AISI 304 (standard)
Stainless steel AISI 316 (option)
Size 1 - below 500mm
Size 2 - below 1000mm
Size 3 - below 2000mm
others on request
PN 16 (others on request)
1" threaded end
others on request
Stainless steel AISI 304
0...80℃ (compact)
0...120℃ (Remote)
PTFE
Stainless steel AISI 316others on request
Protection rating
Repeatability
Compact version - IP67
Remote version - IP68
+/-0.5%
Accuracy+/-1.5% for velocity >1m/s (under proper installation condition) +/-1%(option)
Subject to change without prior notice Ver.: 20180502
Transducers
![Page 10: Electromagnetic Flowmeter / Energy Meter Catalogue Rev2018-07-18.pdf · UCL Series Flowmeter - ver.20171129F (Rev.1.1).cdr Author: SK Created Date: 5/3/2018 1:27:07 PM ...](https://reader034.fdocuments.us/reader034/viewer/2022052019/603292b49a56710863747514/html5/thumbnails/10.jpg)
Subject to change without prior notice Ver.: 20180502
Dimensions in mmUCL3770/UC880
SI ZE DN RANGE
SI ZE1 FROM DN 80 UP TO DN 500
SI ZE2 FROM DN 80 UP TO DN 1000
SI ZE3 FROM DN 80 UP TO DN 2000
Order code
![Page 11: Electromagnetic Flowmeter / Energy Meter Catalogue Rev2018-07-18.pdf · UCL Series Flowmeter - ver.20171129F (Rev.1.1).cdr Author: SK Created Date: 5/3/2018 1:27:07 PM ...](https://reader034.fdocuments.us/reader034/viewer/2022052019/603292b49a56710863747514/html5/thumbnails/11.jpg)
Model UC 880
Description Flow converter
Power Supply 90...250Vac 45...60Hz / 18...36Vdc (option)
Humidity range
Protection rating IP 67
Current output 4...20mA - RL 1000Ω
Full scale value 0.4...10m/s
Accuracy +/- 0.4% m.v. (velocity > 0.4m/s)+/- 0.3% m.v. (velocity > 0.4m/s) - option
CE certification Yes
Pulse / frequency output 0...500Hz pulse, 0...5000Hz frequency
Display capacity 9,999,999,999
Repeatibility Better than 0.1%
Programming Key buttons
RS 485 modbus (option)
Display LCD display
Serial interface
0...100%RH at 65℃
Ambient temperature
Data storage
Programmable- Low flow cut off- Damping- Empty pipe detect
0...50℃
EEPROM stored measuring values on power failure
Enclosure material Aluminum
Turndown ratio 10:1
Subject to change without prior notice Ver.: 20180502
Approvals
This product conforms with the requirements of the following standards harmonizedwith the EMC Directive 2004/108/EC-EN 61326-1: 2006-EN 61000-6-2: 2005-EN 61000-6-4: 2007 + A1: 2011
Flow Converters
- Peak reading- Bi-directional output
Remote Version Compact Version
![Page 12: Electromagnetic Flowmeter / Energy Meter Catalogue Rev2018-07-18.pdf · UCL Series Flowmeter - ver.20171129F (Rev.1.1).cdr Author: SK Created Date: 5/3/2018 1:27:07 PM ...](https://reader034.fdocuments.us/reader034/viewer/2022052019/603292b49a56710863747514/html5/thumbnails/12.jpg)
Order code
Subject to change without prior notice Ver.: 20180502
![Page 13: Electromagnetic Flowmeter / Energy Meter Catalogue Rev2018-07-18.pdf · UCL Series Flowmeter - ver.20171129F (Rev.1.1).cdr Author: SK Created Date: 5/3/2018 1:27:07 PM ...](https://reader034.fdocuments.us/reader034/viewer/2022052019/603292b49a56710863747514/html5/thumbnails/13.jpg)
Model UC 321
* Display simultaneously 4 variables: Q - Flow rate E - Thermal Energy T1 - Temp. hotside T2 - Temp. coldside - Pt100 or Pt1000 paired with 3-wire and 4-wire connection
- Programmable values for specific heat and density of different liquids
- Bi-directional measure of flow
- Display units: (m3, Ltr), (KWh, MWh), (KW, MW, KVA), (℃)
- Additional functions: Low-flow cutoff
- System accuracy: +/- 1.0%
- Min. temperature difference: 0.1℃
- Output: pulse (energy), 4-20mA (flow, power), HART protocol RS485 modbus
- Data storage: EEPROM stored measuring values on power failure
- Display capacity:99,999,999
- Protection rating:IP65
- Power supply:90...250Vac,45...60Hz
- Ambient temperature: 0...50℃
Application
- Heating systems- Cooling systems- Solar-power systems- For communication with building-management systems
Description
Subject to change without prior notice Ver.: 20180502
Heating / cooling energy calculator
ApprovalsThis product conforms with the requirements of the following standards harmonized with the EMC Directive 2004/108/EC
- EN 61000-6-2: 2005- EN 61000-6-4: 2007 + A1: 2011- EN 61000-3-2: 2006 + A1: 2009 + A2: 2009- EN 61000-3-3: 2008- EN 1434-2007 - Heat meters- EN 55081-1 electromagnetic compatibility- EN 55082-2 electromagnetic compatibility
EnergyConverter
![Page 14: Electromagnetic Flowmeter / Energy Meter Catalogue Rev2018-07-18.pdf · UCL Series Flowmeter - ver.20171129F (Rev.1.1).cdr Author: SK Created Date: 5/3/2018 1:27:07 PM ...](https://reader034.fdocuments.us/reader034/viewer/2022052019/603292b49a56710863747514/html5/thumbnails/14.jpg)
Dimensions in mmUC 321
Order code
Subject to change without prior notice Ver.: 20180502
![Page 15: Electromagnetic Flowmeter / Energy Meter Catalogue Rev2018-07-18.pdf · UCL Series Flowmeter - ver.20171129F (Rev.1.1).cdr Author: SK Created Date: 5/3/2018 1:27:07 PM ...](https://reader034.fdocuments.us/reader034/viewer/2022052019/603292b49a56710863747514/html5/thumbnails/15.jpg)
![Page 16: Electromagnetic Flowmeter / Energy Meter Catalogue Rev2018-07-18.pdf · UCL Series Flowmeter - ver.20171129F (Rev.1.1).cdr Author: SK Created Date: 5/3/2018 1:27:07 PM ...](https://reader034.fdocuments.us/reader034/viewer/2022052019/603292b49a56710863747514/html5/thumbnails/16.jpg)
United Controls (Hong Kong) Ltd.
Flat A1, G/F., Tonic Industrial Centre,
26 Kai Cheung Road, Kowloon Bay, Hong Kong
Tel : (852) 2556 1001
Fax: (852) 2556 1298
Email: [email protected]
Website:www.unitedcontrols.com.hk
United Controls(Hong Kong) Ltd.
統一儀器(香港)有限公司