ELECTRODIAGNOSTIC TESTS FOR VERTIGO
Prof. G. Selvarajan
Madras Medical College
Chennai
![Page 2: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/2.jpg)
INTRODUCTION
VERTIGO
Vestibulo ocular
Vestibulo cerebellar
Vestibulo spinal
Vestibulo cortical
![Page 3: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/3.jpg)
VERTIGO
Vestibulo ocular
Vestibulo cerebellar
Vestibulo spinal
Vestibulo cortical
CT MRI
VNG ROTATION
CHAIR
CCG CDP
BEAM Vest EP
![Page 4: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/4.jpg)
VESTIBULO OCULAR
![Page 5: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/5.jpg)
Rotational Chair Test
![Page 6: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/6.jpg)
PROCEDURE
• Hungarian physiologist Bárány Róbert • Pt seated on the chair, blindfolded, ENG
electrodes applied & Head Tilted Forward. • Slow Sinusoidal harmonic acceleration used • Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64 Hz with peak angular velocities 50 degrees/sec at each frequency
• Computer compares Head velocity and Slow phase Eye Velocity.
• Gain, Phase, Symmetry can be studied
![Page 7: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/7.jpg)
• GAIN- slow eye velocity divided by head velocity
b/l vestibular disease
• PHASE ANGLE- measures temporal relation between eye and head velocities-in degrees
peripheral vestibular dysfunction.
cerebellar dysfn.
• SYMMETRY- ratio of rightward to leftward slow wave eye velocity.
Asymmetry means peripheral vestibular weakness on the same side or excitatory weakness on opposite side.
![Page 8: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/8.jpg)
Application
• Research Protocols
• Analyzing horizontal canal vestibuloocular reflex (VOR)
• To diagnose patients with peripheral vestibular lesions
• To monitor patients undergoing pharmacologic vestibular ablation for Ménière syndrome.
• To objectively evaluate efficacy of trt.
![Page 9: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/9.jpg)
VESTIBULO SPINAL
![Page 10: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/10.jpg)
Craniocorpography
• Photographic Record of patients head and body movements
• Performs ROMBERGS and UNTERBERGERS tests
• Crudely classify patients as having central or peripheral vertigo
![Page 11: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/11.jpg)
PROCEDURE
• Dark room
• Convex mirror
• Adjustable Camera
• Helmet with 3 lights
• Recording:
– Untenbergers test for 90steps in 1min
– Rombergs test for 1 min
![Page 12: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/12.jpg)
INTERPRETATION
Only Input to CNS is vestibular. Visual and proprioceptor inputs is eliminated
Peripheral Vestibular Lesions- Sway towards side of hypoactive labyrinth
In central lesion- side to side sway
Breadth of sway - severity of lesion - >10cm sway suggests central lesion
![Page 13: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/13.jpg)
Normal
![Page 14: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/14.jpg)
Peripheral Vestibular lesion Left
![Page 15: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/15.jpg)
Cerebellar Ataxia
![Page 16: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/16.jpg)
Advantages
• Non- invasive, quick
• Objective test for vestibular function
• Can be done on children and patients with perforated Ear drums
![Page 17: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/17.jpg)
Ultrasonic Guided Computerised CCG
![Page 18: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/18.jpg)
Ultrasonic Guided Computerised CCG
![Page 19: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/19.jpg)
Computerized Dynamic Posturography
• To asses to equilibrium as a whole
• Evaluates pts functional postural ability
• The only method that integrates contributions from vestibular, visual, SOM
• Does not help to locate the site or cause of lesion
• Does not replace other tests but supplement them
![Page 20: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/20.jpg)
• Position of centre of gravity- SOT
• To execute automatic movements in body muscles such that centre of gravity is brought back-MCT
![Page 21: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/21.jpg)
![Page 22: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/22.jpg)
Apparatus
![Page 23: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/23.jpg)
Procedure
• Series of tests used to asses overall function of balance as a whole.
• Two test components:
– Sensory Organization Test
– Motor Coordination Test:
• Motor control test
• Adaptation test
![Page 24: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/24.jpg)
Sensory Organisation Test
1. Eyes open, fixed surface/ platform, fixed visual surround.
2. Eyes closed, fixed platform. 3. Eyes open, fixed platform,
sway referenced/ moving visual surround.
4. Eyes open, sway referenced/ moving platform, fixed visual surround.
5. Eyes closed, sway referenced/ moving platform.
6. Eyes open, sway referenced platform and visual surround.
![Page 25: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/25.jpg)
TEST NO.
PICTURE EYES VISUAL SURROUND
PLATFORM
INFERENCES
1. Open Fixed Fixed Pt has apparently compensated condition. This test is used as Ref value for the Equilibrium scores
2. Closed - Fixed Somatosensory input deficit
3. Open Sway Fixed
4. Open Fixed Sway Visual Input deficit
5. Closed - Sway Vestibular input deficit
6. Open Sway Sway Most difficult test, Tests CNS ability to coordinate information
![Page 26: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/26.jpg)
Ratio Comparison Functional Relevance
Somatosensory (SOM)
Condition 2 Condition 1
Patient's ability to use input from somatosensory system to maintain balance
Visual (VIS)
Condition 4 Condition 1
Patient's ability to use input from visual system to maintain balance
Vestibular (VEST)
Condition 5 Condition 1
Patient's ability to use input from vestibular system to maintain balance
Preference (PREF)
Condition 3 + 6 Condition 2 + 5
Inaccurate visual cues result in increased sway compared to absence of visual cues. Hence patient relies on visual cues even if inaccurate.
Sensory Analysis ratios
![Page 27: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/27.jpg)
![Page 28: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/28.jpg)
![Page 29: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/29.jpg)
Motor Coordination/ Control Test • Uses 3 posterior 3 anterior 3
rotations around ankle each of 3 magnitude.
• Output parameter are- 1.latency 2. weight distribution onto each leg 3. Measure of strength depending
upon strength of perturbation Patients response compared with
normal subject of same age.
• Adaptation Test: For each platform rotation, a sway
energy score quantifies the magnitude of the force response required to overcome induced postural instability
![Page 30: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/30.jpg)
Strategy Analysis and COG
Strategy Analysis:
quantifies the relative amount of movement of ankles (ankle strategy) and hips (hip strategy) that patient used to maintain balance during each trial.
Normal, stable individuals move primarily ankle joints when surface is stable and shift to hip movements as they become less stable.
COG Alignment:
Reflects patient's COG position relative to center of base of support at the start of each trial of SOT.Normal individuals maintain their COG near the center of support base.
![Page 31: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/31.jpg)
INTERPRETATION
• Unilateral: Prolonged latency – peripheral Nerve Lesion
• Unidirectional: Peripheral Nerve or Motor Tract Lesion
• Bilateral/ Bidirectional: Systemic CNS disorder (Multiple sclerosis, polyneuropathy)
![Page 32: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/32.jpg)
ADVANTAGES • Highly sensitive for central pathologies:
Vestibular and non-Vestibular CNS pathology
• Asses integrity of CNS to detect defects when
the 3 sensory inputs send in contradictory
information
• To determine management protocols e.g.
darkness, uneven surfaces.
• To individualize Vestibular rehabilitation
exercises
![Page 33: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/33.jpg)
VESTIBULO CORTICAL
![Page 34: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/34.jpg)
BEAM
• Brain Electrical Activity Mapping
• this is a topographic representation of the EEG in response to Vestibular stimuli – Vest EP
• Vestibular stimulation- electrical activity in brain central processing. Recorded by surface electrode on the scalp
• Vestibulo cortical aspects of balance.
• A recent tool in the diagnosis of vertigo
• Following the heirarchy of VEMP and ABR,
![Page 35: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/35.jpg)
Procedure
• Vestibular Stimuli: rotational stimuli – using square wave signals - stimulating natural head movements
• Patient seated in a rotational chair – head fixed, rotated clockwise and counter clockwise with acc/deceleration pulses of short duration
• There is no exact stimuli – different types preferred by different researchers
• Multiple EEG electrodes
![Page 36: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/36.jpg)
LORETA
Low Resolution Electromagnetic Tomography Talairach Atlas
![Page 37: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/37.jpg)
Electrocochleography
• technique of recording stimulus-related responses or electrical potentials of the inner ear.
• Extension of ABR protocol
• Electrode is placed close to tympanic membrane or cochlea
• Auditory Stimulus - click or tone burst presented at a relatively slow rate (11.1/sec).
• Response collected from 0 to 5 msecs.
• Used mainly in Ménière's disease.
![Page 38: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/38.jpg)
• The components of ECochG are: – CM (cochlear microphonic) - Stimulus-dependent
cochlear response, which changes direction with changing polarity.
– SP (summating potential) - direct current response from Organ of Corti hair cells. Leading hump on AP or wave I (sometimes it is a separate hump).
– AP (action potential) - alternating current response generated by cochlear end of 8th nerve (wave I). Represents summed response of thousands of firing auditory nerve fibers.
![Page 39: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/39.jpg)
PROCEDURE
• Electrodes placement: – Ear-canal: tip-trode (gold foil) - Foil covered foam insert
piece in external ear canal – does not touch TM – Extra tympanic: tymptrode - thin coated wire placed in
ear canal - rests gently on TM – Transtympanic: needle electrode - placed through TM -
rests on oval window/ promontory
• Electrode on the forehead is ground • Stimulus given: 1000 to 2000 clicks to an ear for each
test run and records the activity for 5 milliseconds after each click.
• The system records and averages each response
![Page 40: ELECTRODIAGNOSTIC TESTS FOR VERTIGO•Slow Sinusoidal harmonic acceleration used •Vestibular stimuli: Head & body rotation is given – at frequencies of 0.01, 0.02, 0.04.upto 0.64](https://reader030.fdocuments.us/reader030/viewer/2022040919/5e952c5d8cd7f465df19e219/html5/thumbnails/40.jpg)
Tracing