ELECTROCHEMISTRY CHEM 4700 CHAPTER 5

34
ELECTROCHEMISTRY CHEM 4700 CHAPTER 5 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university

description

ELECTROCHEMISTRY CHEM 4700 CHAPTER 5. DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university. CHAPTER 5 POTENTIOMETRY. POTENTIOMETRY. - Based on static (zero-current) measurements - PowerPoint PPT Presentation

Transcript of ELECTROCHEMISTRY CHEM 4700 CHAPTER 5

Page 1: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

ELECTROCHEMISTRY

CHEM 4700

CHAPTER 5

DR. AUGUSTINE OFORI AGYEMANAssistant professor of chemistryDepartment of natural sciences

Clayton state university

Page 2: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

CHAPTER 5

POTENTIOMETRY

Page 3: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

- Based on static (zero-current) measurements

- Used to obtain information on the composition of an analyte

- Potential between two electrodes is measured

Applications- Environmental monitoring

- Clinical diagnostics (blood testing, electrolytes in blood)- Control of reaction processes

POTENTIOMETRY

Page 4: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

- Also known as indicator electrodes

- Respond directly to the analyte

- Used for direct potentiometric measurements

- Selectively binds and measures the activity of one ion (no redox chemistry)

ExamplespH electrode

Calcium (Ca2+) electrodeChloride (Cl-) electrode

ION-SELECTIVE ELECTRODES (ISE)

Page 5: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

Advanteages

- Exhibit wide response

- Exhibit wide linear range

- Low cost

- Color or turbidity of analyte does not affect results

- Come in different shapes and sizes

ION-SELECTIVE ELECTRODES (ISE)

Page 6: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

- Made from a permselective ion-conducting membrane(ion-exchange material that allows ions of one electrical

sign to pass through)

- Reference electrode is inbuilt

- Internal solution (solution inside electrode) contains ion of interest with constant activity

- Ion of interest is also mixed with membrane

- Membrane is nonporous and water insoluble

ION-SELECTIVE ELECTRODES (ISE)

Page 7: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

- Responds preferentially to one species in solution

Internal reference electrode

Ion-selective membrane

Internal (filling) solution

ION-SELECTIVE ELECTRODES (ISE)

Page 8: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

- Selective (preferential) ion is C+

- Membrane is made of poly(vinyl chloride) (PVC)

- Membrane is impregnated with nonpolar liquid

- Membrane contains ligand L (ion-selective ionophore)

- Membrane contains the complex LC+

- Membrane contains hydrophobic anion R- (ion exchanger)

ION-SELECTIVE ELECTRODES (ISE)

Page 9: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

- [C+] inside the electrode ≠ [C+] outside the electrode

- Results in a potential difference across the membrane

Generally (at 25 oC)- 10-fold change in activity implies 59/zi mV change in E- zi is the charge on the selective ion (negative for anions)

- zi = +1 for K+, zi = +2 for Ca2+, zi = -2 for CO32-

ION-SELECTIVE ELECTRODES (ISE)

inner

outer

i ][C

][Cln

Fz

RTE

inner

outer

i

o

][C

][Clog

z

0.05916EC, 25At

Page 10: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

- Let ci = molarity of C+

- Activity (ai) rather than molarity is measured by ISEs

- Activity is the effective (active) concentration of analyte(effective concentration decreases due to ionic interactions)

- zi = ionic charge (±)

ai = γici

where γi = activity coefficient (between 0 and 1)

ION-SELECTIVE ELECTRODES (ISE)

Page 11: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

Debye-Hückel Equation

- Relates activity coefficients to ionic strength (at 25 oC)

α = size of ion in picometers (1 pm = 10-12 m)

µ = ionic strength

/305)μ(α1

μ0.51zγlog

2i

ION-SELECTIVE ELECTRODES (ISE)

Page 12: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

Ionic strength- A measure of the concentration of all ions in solution

with their charges taken into account

.........zczczc2

1zc

2

1μ 2

ii2ii

2ii

i

2ii

ci = the concentration of the ith species

Ionic strength of electrolytes1:1 electrolytes (NaCl) µ = molarity

2:1 electrolytes (CaCl2) µ = 3 x molarity3:1 electrolytes (AlCl3) µ = 6 x molarity2:2 electrolytes (MgSO4) µ = 4 x molarity

ION-SELECTIVE ELECTRODES (ISE)

Page 13: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

- For very dilute solutions ai ≈ ci

- Activity coefficient decreases as ionic strength increases

For zi = 1- 1 mV change in potential implies 4% change in activity

For zi = 2- 1 mV change in potential implies 8% change in activity

- This is known as Nernstian behavior

ION-SELECTIVE ELECTRODES (ISE)

Page 14: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

Selectivity Coefficient (k)

- A measure of the ability of ISE to discriminate against an interfering ion

- It is assumed that ISEs respond only to ion of interest

- In practice, no electrode responds to only one specific ion

- The lower the value of k the more selective is the electrode

- k = 0 for an ideal electrode (implies no interference)

ION-SELECTIVE ELECTRODES (ISE)

Page 15: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

Selectivity Coefficient (k)

For k > 1- ISE responds better to the interfering ion than to the target ion

For k = 1- ISE responds similarly to both ions

For k < 1- ISE responds more selectively to ion of interest

ION-SELECTIVE ELECTRODES (ISE)

Page 16: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

Empirical Calibration PlotP

oten

tial

(m

V)

p[C+]

Slope = 59/zi mV

zi = charge of ion

Called Nernstian slope

- Used to determine the unknown concentration of analytes

- Departure from linearity is observed at low concentrations

ION-SELECTIVE ELECTRODES (ISE)

Page 17: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

Three groups of ISEs

- Glass electrodes

- Liquid electrodes

- Solid electrodes

ION-SELECTIVE ELECTRODES (ISE)

Page 18: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

GLASS ELECTRODES

- Responsive to univalent cations

- Employs thin ion-selective glass membrane

Page 19: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

pH GLASS ELECTRODE

- The most widely used

- For pH measurements (selective ion is H+)

- Response is fast, stable, and has broad range

- pH changes by 1 when [H+] changes by a factor of 10

- Potential difference is 0.05196 V when [H+] changes by a factor of 10

For a change in pH from 3.00 to 6.00 (3.00 units)Potential difference = 3.00 x 0.05196 V = 0.177

Page 20: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

pH GLASS ELECTRODE

- Thin glass membrane (bulb) consists of SiO4

- Most common composition is SiO2, Na2O, and CaO

Glass membrane contains - dilute HCl solution

- inbuilt reference electrode (Ag wire coated with AgCl)

Page 21: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

pH GLASS ELECTRODE

Glass Electrode Response at 25 oC (potential across membrane with respect to H+)

ΔpH = pH difference between inside and outside of glass bulb

β ≈ 1 (typically ~ 0.98)(measured by calibrating electrode in solutions of known pH)

K = assymetry potential (system constant, varies with electrodes)

ΔpHβ(0.05916)KE

)(a0.05916log -KEH

Page 22: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

pH GLASS ELECTRODE

- Equilibrium establishes across the glass membrane with respect to H+ in inner and outer solutions

- This produces the potential, E

- Linearity between pH and potential

- Calibration plot yields slope = 59 mV/pH units

- Electrode is prevented from drying out by storing in aqueous solution when not in use

Page 23: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

pH GLASS ELECTRODE

Sources of Error

- Standards used for calibration- Junction potential- Equilibration time

- Alkaline (sodium error)- Temperature- Strong acids

- Response to H+ (hydration effect)

Page 24: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

OTHEER GLASS ELECTRODES

Glass Electrodes For Other CationsK+ -, NH4

+-, Na+-selective electrodes- Mechanism is complex

- Employs aluminosilicate glasses (Na2O, Al2O3, SiO2)- Minimizes interference from H+ when solution pH > 5

pH Nonglass Electrodes- Quinhydrone electrode (quinone – hydroquinone couple)

- Antimony electrode

Page 25: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

LIQUID MEMBRANE ELECTRODES

- Employs water-immiscible substances impregnated in a polymeric membrane (PVC)

- For direct measurement of polyvalent cations and some anions

- The inner solution is a saturated solution of the target ion

- Hydrophilic complexing agents (e.g. EDTA) are added to inner solutions to improve detection limits

- Inner wire is Ag/AgCl

Page 26: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

Ion-Exchange Electrodes

- The basis is the ability of phosphate ions to form stable complexes with calcium ions

- Selective towards calcium

- Employs cation-exchanger that has high affinity for calcium ions(diester of phosphoric acid)

- Inner solution is a saturated solution of calcium chloride

- Cell potential is given by )log(a2

0.05916KE

aC

LIQUID MEMBRANE ELECTRODES

Page 27: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

Other Ion-Exchange Electrodes

- Have poor selectivity and are limited to pharmaceutical formulations

Examples- IEE for polycationic species (polyarginine, protamine)

- IEE for polyanionic species (DNA)- IEE for detection of commonly abused drugs

(large organic species)

LIQUID MEMBRANE ELECTRODES

Page 28: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

Neutral Carrier Electrodes

- Employs neutral carriers such as crown ethers and cyclic polyesters

- Carriers envelope target ions in their pockets

Used for clinical analysis- detection of blood electrolytes

- detection alkali and alkaline earth metal cations

LIQUID MEMBRANE ELECTRODES

Page 29: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

Neutral Carrier Electrodes

Examples of Carriers- Monensin for sodium

- Macrocyclic thioethers for Hg and Ag- Valinomycin for potassium ions- Calixarene derivatives for lead- 14-crown-4-ether for lithium

LIQUID MEMBRANE ELECTRODES

Page 30: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

Anion-Selective Electrodes

- For sensing organic and inorganic anions

Examples of Anions- Phosphate- Salicylate

- Thiocyanate- Carbonate

LIQUID MEMBRANE ELECTRODES

Page 31: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

SOLID-STATE ELECTRODES

- Solid membranes that are selective primarily to anions

Solid-state membrane may be - single crystals

- polycrystalline pellets or

- mixed crystals

Page 32: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

SOLID-STATE ELECTRODES

Examples - Most common is fluoride-ion-selective electrode

(limited pH range of 0-8.5)(OH- is the only interfering ion due to similar size and charge)

- Iodide electrode (high selectivity over Br- and Cl-)

Chloride electrode (suffers interference from Br- and I-)

Thiocynate (SCN-) and cyanide (CN-) electrodes

Page 33: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

OTHER ELECTRODES

- Coated-wire electrodes (CWE)

- Solid-state electrodes without inner solutions

- Made up of metallic wire or disk conductor (Cu, Ag, Pt)

- Mechanism is not well understood due to lack of internal reference

- Usually not reproducible

For detection ofamino acids, cocaine, methadone, sodium

Page 34: ELECTROCHEMISTRY CHEM 4700 CHAPTER  5

APPLICATIONS OF ISEs

- Used as detectors for automated flow analyzers(flow injection systems)

- High-speed determination of blood electrolytes in hospitals(H+, K+, Cl-, Ca2+, Na+)

- For measuring soil samples (NO3-, Cl-, Li+, Ca2+, Mg2+)

- Coupling ion chromatography with potentiometric detection

- Micro ISEs as probe tips for SECM

- Column detectors for capillary-zone electrophoresis