Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats...

48
Product Catalogue Electrical Safety Equipment

Transcript of Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats...

Page 1: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

Product Catalogue

Electrical Safety Equipment

Page 2: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au2

INDEX:What is an Arc Flash?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Free Trial Offer - Arc Flash Training. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Electrical Standards Explained - NFPA 70E is the world’s leading standard on Arc Flash protection and risk mitigation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Make the Right Choice! Cat Ratings Explained. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

NFPA 70E / CZA Z462 Category Quick Reference Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

SIZING CHARTS:

Clothing Sizing Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Outer Glove Sizing Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Rubber Gloves Sizing Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Insulating Gloves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9,10

Low Voltage Insulating Glove Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Gloves Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

LEATHER OUTERS AND ACCESSORIES:

Outer Glove - Goat Skin for Class 00 and 0 Gloves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Live Line for Class 1 - 4 Gloves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Insulating Mats. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Insulating Mats Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

ARC FLASH PERSONAL PROTECTIVE EQUIPMENT:

Nomex Arc Flash Suit 65cal/cm2 suit for Extra High Risk Applications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Nomex Arc Flash Suit 44.8cal/cm2 for High Risk Applications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

DEHN Protective Clothing - Cat 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Cat 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Cat 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18-21

Cat 0. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

ACCESSORIES:

Arc Flash 10cal/cm2 Faceshield with Smoke Tint and Removable Chinguard. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Accessories - Items That Go Perfectly with Arc Flash PPE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23, 25

ARC FLASH KITS:

Cat 2 Arc Flash Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Cat 4 Arc Flash Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Page 3: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au 3

LOCKOUT KITS:

Lockout Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27, 28, 29

Components for Lockout Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

SAFETY KITS:

Harnesses and Height Safety Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

Lanyards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

Karabiners. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

RESCUE KITS:

LV Switchboard Rescue Kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

Rescue Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

BOOTS:

Insulated 1000V QuickFit Rubber Overoot. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

Boots. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

GENERAL SAFETY:

Safety Glasses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

General Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39, 40

Traffic Control and Fire Fighting Equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

First Aid Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

SPILL KITS:

Spill Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

PORTABLE EARTHING DEVICES:

Insulating Covers, Mats and Tiger Tails®. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

10 Things to Reconsider with Your Portable Earthing Device. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

Why Choose DEHN and Extreme Safety?.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

Portable Earthing Devices - HV Earthing Set for OH Lines or Switchboard. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44, 45

Discharge Device for Voltage Discharge After HV Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

Accessories - Attachment Points and Tools for PEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

Custom Earth Sets - Order Form. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

Notes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

Page 4: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au4

Hand with Arc Flash Burns

Severe Arc Flash injury to inner arm

Typical Arc Flash injuries

What is Arc Flash?An Arc Flash or arc fault happens when electric current flows through air gaps between conductors, causing a short circuit.

When does it occur?Arc flashes often occur when racking in a breaker, performing switching, due to insulation failure, or accidents caused by touching a test probe to the wrong surface or slipped (non-insulated) tools.

What makes up an Arc Flash? In its most basic form, an arc is made up of four elements; thermal energy (heat), acoustical energy (sound), pressure wave and debris. Each of these elements can cause serious injury or death to a person.

The dangerous partThe most dangerous part of an Arc Flash incident is the fact that it creates temperatures high enough to burn skin, but also ignite non Arc rated clothing. Burns due to burning clothing are the most serious, involve large percentages of the body and are more often than not, fatal.

For more information on Arc Flash, visit our education site at arcflash.com.au

• Test Set Up

• 37cal/cm² or 10kA/1sec rated Arc Flash jacket ready for testing

• The garment has never been worn, however has been laundered industrially 50 times

• The garment is a dual layer Proban construction, of 330gsm per layer

• The initial Arc Flash ignition is anywhere between 9,000º & 20,000º C

• The copper in the switchboard is vaporised and expands to over 40,000 times its solid volume

• Plasma is generated by the arc putting the garment under immense heat and pressure

• The arc continues for 1 full second, as a result of high fault current and slow trip times

• The manikin is equipped with temperatures sensors, none of which may surpass levels that would cause second degree burns

• The garment cannot break open at all or it will fail the test

• The garment passes this test at 10kA/1sec or 37cal/cm²

• No part of the garment breaks open, and no temp sensor register a second degree burn value

• A worker wearing this garment with other appropriate PPE would have had none, or only minor injuries

WHAT IS AN ARC FLASH?Timed Sequence over one second of the Arc Flash

Page 5: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au 5

ONE FLASH AND YOU'RE GONE

MAKE THE RIGHT CHOICEFREE 20 MINUTE LIFE PROTECTION COURSETry our free 20-minute online training course about Arc Flash protection.

Go to www.extreme.protraining.com It could be the smartest 20 minutes you ever spend in your work.

Page 6: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au6

Standards ExplainedNFPA 70E is the world’s leading standard on Arc Flash protection and risk mitigation.NFPA 70E is the world’s leading standard on Arc Flash protection and risk mitigation. Part of the standard, is a list of categories designed to advise and determine protection categories for equipment and clothing.

The categories (Cat) range from Cat 0 through to Cat 4. The lower the number, the lower the risk of a piece of equipment, or the lower the protection of a garment. The higher the number, the higher the risk of a piece of equipment and the higher the protection on clothing.

Clothing should always be selected to match, or be higher than the Cat rating of the equipment being worked on. Each Category covers a range of Arc Flash protection ratings, which are measured in calories per square centimeter (cal/cm2). The higher a cal/cm2 rating, the higher the category, and the higher the risk from equipment (or protection from a garment).

When NFPA 70E was written, the categories were based on the number of fabric layers required to achieve a certain level of protection. For example, to get 10cal/cm2 protection, with the fabrics at the time, two layers were needed (so it was called Cat 2). Technology and fabric advances mean this old adage no longer applies, and Cat 1 and 2 can now both be achieved with single layer, Cat 3 can be achieved with only two layers, and so on.

Standard Number

Standard Scope Notes

AS2225 Electrical Gloves Australian Standard, based on superseded British Standard. Only covers up to 7000V

AS4836 Working Live or Near Live Mandates Arc Flash protective clothing and equipment

AS3000 Wiring Rules Australian Wiring Regulations

NFPA 70E Arc Flash and Electrical Safety American Arc Flash and Safety standard. Industry best practice, widely used in Australia

CSA Z462 Arc Flash and Electrical Safety Canadian version of NFPA 70E (above)

AS/NZS 2978 Electrical Mats Australian Standard for rubber matting

IEC60903 Electrical Gloves European Standard for electrical gloves, up to 36,000V

IEC 61111 Electrical Mats International Standard for electrical mats, up to 36,000V

ASTM D120 Electrical Gloves American Standard for electrical gloves, up to 36,000V

IEC 61482 Arc Flash International Arc Flash Standard. Replaces ENV50354

IEEE 1584 Arc Flash Calculations Standard for equipment / switchboard calculations on Arc Flash hazard values

BG1/GUV-15188E Arc Flash and Electrical Safety European guide for easy selection of Arc Flash protective equipment

Electrical Safety Standards

Maintain a safe work environment We recommend regular 6 month HV testing of the following products:

LV and HV Insulating Gloves | Insulation Mats | LV Switchboard Rescue Kit | HV rescue Kit

For further information contact your local distributor or go to website.

We recommend you refer to your State Electrical or Safety Government department to check your local legislation regarding testing.

Page 7: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au 7

CAT 2 (8-25CAL/CM2

NFPA 70E)This category achieves the ‘magic number 8’ of 8cal/cm2, which many companies have deemed to be the minimum for all day workwear.

The thinnest and lightest Cat 2 fabrics can be as light as 235gsm (grams per

square meter) single layer.

This is suitable for all but the most humid climates.

CAT 4 (40CAL/CM2

NFPA 70E)The most popular choice for high risk tasks, Cat 4 garments are rated upwards of 40cal/cm2 and provide the highest protection offered under the standard. When risk levels are high, and piece of mind is an absolute must, Cat 4 is the most

popular choice. Although thicker fabrics and multi layer constructions are required to achieve this category, developments in fabric means garments are no longer as hot, bulky and uncomfortable as they once were.

CAT 0 (NO CAT RATING AS4836)No cal/cm2 rating, and is simply flame retardant (FR). It is possible for a garment to be flame retardant, and not have an Arc Flash cal rating. It is not possible to have a cal rating without being flame retardant. This is because an Arc Flash cal rating is achieved by exposure to an Arc Flash test, while an FR garment or fabric is simply exposed to a static flame test. As such, we know all Arc Flash cal rated garments will pass a FR test as they must be FR to pass the Arc Flash test. A fabric that passes only a FR static flame test, is by no means guaranteed to pass an Arc Flash cal rating test.

CAT 3 (26-39CAL/CM2

NFPA 70E)This is the least used or popular category in NFPA 70E, as many companies will jump straight from Cat 2 workwear, to Cat 4 high risk protection to achieve 40cal/cm2, leaving out Cat 3.

Despite this, Cat 3 is still an excellent

option as it can provide very close to 40cal/cm2 with less layers, and is still a very protective garment.

For example, a two layer switching coat can provide in the high-30s of cal/cm2 rating.

NB: It is important not to confuse the Cat rating of Arc Flash garments/equipment with the Cat rating of test and measurement equipment, these are in no way related.

* Not an official rating in NFPA 70E, but an industry accepted term for anything exceeding Cat 4.

CAT 1 (4-7CAL/CM2 NFPA 70E)The popularity of Cat 1 clothing for all day workwear is increasing exponentially.

Previously it was seen as a ‘must have’ to have over 8cal/cm2 for workwear.

This is changing, with more and more companies accepting lower values (5-7cal/cm2) for their workwear, in order to achieve wearability and breathability benefits only offered by lighter but lower rated fabrics.

Make The Right Choice!Use our NFPA 70E guide to help you choose the right protection

NFPA 70E / CZA Z462 Category Quick Reference GuideCategory Cal Rating Recommended PPE

0 0cal/cm2 Cotton

1 <8cal/cm2 90-500, 90-501, 90-502, 140204BSDERGOS, 140201-HRP, 0019-SIZE

2 8-25cal/cm2 90-US500, 90-US501, 90-US502, 140204BSDERGOS, 140201-HRP, 0024B-NOMEX, 0584R-SIZE, 0019-SIZE

3 26-39cal/cm2 91-488-SIZE, 91-881198-SIZE, 91-551793-SIZE, 91-881201-SIZE, 140204NX, D-785799

4 >40cal/cm2 90-488-SUIT-SIZE, 0017-40-XL

Extreme* >60cal/cm2 90-491-SUIT-SIZE

PLEASE NOTE:These tables are a guide only, always refer to the latest version of local, national or international standards before making your decision

of what safety equipment to wear.

Page 8: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au8

SIZING CHARTS

Clothing Sizing Guide (Multi brand and sizing methods)US Size XS S M L XL 2XL 3XL 4XL

EU Size 46 48 50 52 54 56 58 60

AUS Size 72R 82R 87R 92R 97R 102R 107R 112R

Shirt Size 39 40 41 42 43 44 45 46

Chest 92 96 100 104 108 112 116 120

Waist 80 84 88 92 96 100 106 112

Neck 39 40 41 42 43 44 45 46

Inside Leg 77 78 79 80 81 82 82.5 83

Arm Length 62.5 62.5 63.5 64 64.5 65 65.5 66

NOTE: All measurements are in centimetres.

THIS IS A GUIDE ONLY. FOR EXACT FITTING PLEASE REQUEST A SIZE CHART SPECIFIC TO THE GARMENT OF INTEREST, OR A SAMPLE GARMENT.

Outer Glove Sizing Guide

Class of Insulated Glove Recommended Outer GloveRecommended Size

of Outer Glove

00 0019-size Insulated Glove size

0 0019-size Insulated Glove size

1 0019-size or 0020-size Insulated Glove size + 1/2 size up

2 0020-size Insulated Glove size + 1 size up

3 0020-size Insulated Glove size + 2 sizes up

4 0020-size Insulated Glove size + 3 sizes up

Knuckle Circumference (cm) Size

20.3 8

22.9 9

25.4 10

27.9 11

Rubber Gloves Sizing GuideGlove sizing is imperative to ensure you maintain good feel and dexterity. Use the following guide to choose the right size for you:

EG: For a knuckle circumference of 24cm, you would choose a Size 10.

Page 9: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au 9

INSULATING GLOVES

Maintain a safe work environment. We recommend regular 6 month HV testing of these products. Contact us for information on testing.

Part No. LengthSize

Description8 9 10 11

AUSTRALIAN STANDARD GLOVES AS2225 - 650V

0588-650-09

360mm

3• Approved to Australian Standard AS2225• 650V working voltage

0588-650-10 3

0588-650-11 3

AUSTRALIAN STANDARD GLOVES AS2225 - 1000V

0588-09

360mm

3• Approved to Australian Standard AS2225• 1000V working voltage

0588-10 3

0588-11 3

IEC STANDARD GLOVES IEC60903 - 500V - CLASS 00

0583H-08

360mm

3 • 500V and Class 00 Approved• Approved to IEC60903• Thin for great dexterity with straight edge cuff• High quality latex construction

0583H-09 3

0583H-10 3

0583H-11 3

IEC STANDARD GLOVES IEC60903 - 1000V - CLASS 0

0584H-08

360mm

3 • 1000V and Class 0 Approved• Approved to IEC60903

• Thin for great dexterity with straight edge cuff• High quality latex construction

0584H-09 3

0584H-10 3

0584H-11 3

IEC STANDARD GLOVES IEC60903 - 7500V - CLASS 1

0585H-09

360mm

3 • 7500V and Class 1 Approved• Approved to IEC60903• Thin for great dexterity with straight edge cuff• High quality latex construction

0585H-10 3

0585H-11 3

IEC STANDARD GLOVES IEC60903 - 17000V - CLASS 2

0586H-09360mm

3• 17000V and Class 2 Approved• Approved to IEC60903• Single colour with straight edge cuff• High quality latex construction

0586H-10 30586H-11 3

IEC STANDARD GLOVES IEC60903 - 26500V - CLASS 3

0587H-09

360mm

3 • 26500V and Class 3 Approved• Approved to IEC60903• Thin for great dexterity with straight edge cuff• High quality latex construction

0587H-10 3

0587H-11 3

IEC STANDARD GLOVES IEC60903 - 36000V - CLASS 4

0589H-10410mm

3• 36000V and Class 4 Approved• Approved to IEC60903• Thin for great dexterity with straight edge cuff• High quality latex construction0589H-11 3

650V Working Voltage Gloves

• IEC60903 and AS2225 certified models available

• One of the world’s most trusted safety brand

AS2225 AND IEC60903APPROVED

Page 10: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au10

INSULATING GLOVES

Part No. LengthSize

Description8 9 10 11

IEC STANDARD GLOVES IEC60903 - 500V - CLASS 00

0583RX-08 360mm 3 • 500V and Class 00 Approved• Approved to IEC60903• Thin for great dexterity with straight edge cuff• High quality latex construction

0583RX-09 360mm 3

0583RX-10 360mm 3

0583RX-11 360mm 3

IEC STANDARD GLOVES IEC60903 - 1000V - CLASS 0

0584RX-08 360mm 3 • 1000V and Class 0 Approved• Approved to IEC60903• Thin for great dexterity with straight edge cuff• High quality latex construction

0584RX-09 360mm 3

0584RX-10 360mm 3

0584RX-11 360mm 3

IEC STANDARD GLOVES IEC60903 - 7500V - CLASS 1

0585RX-09 360mm 3 • 7500V and Class 1 Approved• Approved to IEC60903• Thin for great dexterity with straight edge cuff• High quality latex construction

0585RX-10 360mm 3

0585RX-11 360mm 3

IEC STANDARD GLOVES IEC60903 - 17000V - CLASS 2

0586RX-09 410mm 3 • 17000V and Class 2 Approved• Approved to IEC60903• Thin for great dexterity with straight edge cuff• High quality latex construction (composite for

Flex and Grip gloves)• Single or dual colour available• Dual colour ‘Flex and Grip’ option doesn’t

need leather outer gloves

0586RX-10 410mm 3

0586RX-11 410mm 3

DUAL COLOUR

0586RX-10-D 410mm 3

0586RX-11-D 410mm 3

IEC STANDARD GLOVES IEC60903 - 26500V - CLASS 3

0587RX-09 410mm 3 • 26500V and Class 3 Approved• Approved to IEC60903• Thin for great dexterity with straight edge cuff• High quality latex construction (composite for

Flex and Grip gloves)• Single or dual colour available• Dual colour ‘Flex and Grip’ option doesn’t

need leather outer gloves

0587RX-10 410mm 3

0587RX-11 410mm 3

DUAL COLOUR

0587RX-10-D 410mm 3

0587RX-11-D 410mm 3

IEC STANDARD GLOVES IEC60903 - 36000V - CLASS 4

0589RX-10 410mm 3 • 36000V and Class 4 Approved• Approved to IEC60903• Thin for great dexterity with straight edge cuff• High quality latex construction (composite for

Flex and Grip gloves)• Single or dual colour available

0589RX-11 410mm 3

DUAL COLOUR

0589RX-10-D 410mm 3

0589RX-11-D 410mm 3

500V Working Voltage Gloves

17000V Working Voltage Gloves Dual Colour/Flexi Grip

• Approved to IEC60903

• European made quality

• ‘Flexi Grip’ range enables you to not wear outer gloves from Class 2 upwards IEC60903APPROVED

Maintain a safe work environment. We recommend regular 6 month HV testing of these products. Contact us for information on testing.

Page 11: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au 11

LOW VOLTAGE INSULATING GLOVE KITS

GLOVE ACCESSORIES

Part No. Size Glove Bag x 1

0021-1

Outer Glove Goat Skin x 1

0019-XX

Cotton Inner Gloves x 12

0023-FA

CLASS 00 500V INSULATED 290MM GLOVE KITS

0582R-KIT-09 9 3 3 3

0582R-KIT-10 10 3 3 3

0582R-KIT-11 11 3 3 3

CLASS 00 500V INSULATED 360MM GLOVE KITS

0583R-KIT-09 9 3 3 3

0583R-KIT-10 10 3 3 3

0583R-KIT-11 11 3 3 3

CLASS 0 DURABLE 1000V INSULATED 410MM GLOVE KITS

0584R-KIT-09 9 3 3 3

0584R-KIT-10 10 3 3 3

0584R-KIT-11 11 3 3 3

NOTE: It is our recommendation that leather outer gloves be worn as mechanical protection for insulating gloves. It is not required by the safety regulations that these gloves be worn. They will however prolong the life and increase the safety of your Insulating Gloves.

Cotton gloves absorb sweat and stop rubber deterioration.

Part No. Features Image Description

CANVAS GLOVE BAGS FOR ALL APPLICATIONS

0021-1 Single Compartment• For storage of electrical gloves and accessories• Various compartment configurations available• Hook and loop grip/strip closure - durable canvas• Fits Class 00-4 Gloves

0021-3 3 Compartment (Standard)

0021-3-LONG 3 Compartment (for Sleeves)

COTTON INNER GLOVES - FOR USE WITH ALL RUBBER GLOVES

0023-F Female

• Available in packs of 12 pairs only • For use with all rubber gloves

0023-FA One Size Fits All

0023-08 Size 8

0023-09 Size 9

0023-10 Size 10

GLOVE TALC

0581-100 Glove Talc 100G

• Talcum powder for use with electrical insulating gloves - absorbs sweat and keeps sanitary levels high

• Size: 100g• Supplied in easy to use bottle• 100% Talc

0021-3 0021-1

Refer to pages 6-7 for detailed explanation on rating system.

Maintain a safe work environment. We recommend regular 6 month HV testing of these products. Contact us for information on testing.

Page 12: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au12

EN388 APPROVEDKEVLAR STITCHING

LEATHER OUTERS AND ACCESSORIESOuter Glove Goat Skin for Class 00 and 0 Gloves• The most trusted and well known outer glove. Long lasting, tough, yet still easy to work in• Will out perform any other brand of gloves in the dexterity test• Perfect for line work or jointing tasks. Goat skin gloves now AS/NZS2161.3:2005, EN420 and EN388 approved• For Class 00 and 0 gloves• Suitable for 10cal/cm2 according to NFPA 70E 2012

Live Line Outer Cowhide Gloves for Class 1 - 4 Gloves• The best live line glove money can buy. No need to ‘wear-in’• Built in flash guard increases safety levels even further• For Class 1 - 4 gloves• Rated to 10cal/cm2 according to NFPA 70E 2012

Part No.Size

7 8 9 9.5 10 10.5 11 11.5 13 14

OUTER GOAT SKIN GLOVE FOR CLASS 00 AND 0 GLOVES

0019-7 3

0019-8.0 3

0019-9.0 3

0019-9.5 3

0019-10 3

0019-10.5 3

0019-11 3

0019-11.5 3

0019-13 3

0019-14 3

OUTER GOAT SKIN GLOVE WATER RESISTANT

0019-WR-9 3

0019-WR-9.5 3

0019-WR-10 3

0019-WR-10.5 3

0019-WR-11 3

OUTER SHEEP SKIN GLOVE FOR CLASS 00 AND 0 GLOVES

0018-8 3

0018-9 3

0018-9.5 3

0018-10 3

0018-10.5 3

0018-11 3

0018-11.5 3

Part No.Size

8.5 9 9.5 10 10.5 11 11.5 12 13

LIVE LINE HIGH VOLTAGE OUTER COWHIDE GLOVES FOR CLASS 1 - 4

0020-8.5 3

0020-9 3

0020-9.5 3

0020-10 3

0020-10.5 3

0020-11 3

0020-11.5 3

0020-12 3

0020-13 3

0019-SIZE

0019-WR-SIZE

0018-SIZE

0020- SIZE

Refer to pages 6-7 for detailed explanation on rating system.

Page 13: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au 13

INSULATING MATS

NB: Tools are not included

LV/HV Mats

Busbar mat

INSULATING MATS ACCESSORIES

Part No. Features Image Description

MAT STRAP

01003STRAP 300 x 300mm• Handy strap to keep rubber insulated mats rolled up• Waterproof canvas -hook and loop grip/strip fastening• Easy to use

MAT BAG

0021-MAT 300 x 600mm

• Waterproof canvas carry bag for Electrical Mats• Fits all Extreme Safety rubber mats• Durable canvas - triple stitched handles• Hook and loop grip/strip closure

1000V BUSBAR PLASTIC CLIP

140179Busbar Clip Small

(100mm) • 1000V insulated clip for use with Busbar Mats and Curtains• Colour: red• 1000V Rated• IEC Approved

140180Busbar Clip Large

(200mm)

Part No. Size (mm) Description

LV MAT FOR USE UP TO 650V TESTED FOR 650V TO CLAUSE 10.2 OF AS/NZS 2978-1995

01004-CLASSAE 1000 x 1000 x 6 General purpose

01004-CLASSAE -ROLL 1000 x custom x 6 Cut to size up to 10m

HV MAT (CLASS 2) FOR USE UP TO 17kV CLAUSE 5.6.4.2.2 OF IEC61111

01004HVE 900 x 900 x 6.5mm For use up to 17kV

HV MAT (CLASS 4) FOR USE UP TO 36kV CLAUSE 5.6.4.2.2 OF IEC61111

01006-12E 1000 x 1000 x 12 For use up to 36kV

BUSBAR MATS CLEAR MATTING TO USE AS A CURTAIN/PARTITION - FOR USE UP TO CLAUSE 5.6.2.2 OF IEC61112W

01006300x300 300 x 300 x 1 For use up to 500V

01006300x600 300 x 600 x 1 For use up to 500V

01006600X600 600 x 600 x 1 For use up to 500V

Maintain a safe work environment. We recommend regular 6 month HV testing of these products. Contact us for information on testing.

Page 14: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au14

LOOSE FIT

To suit various bodyshapes, and for easy fitover other work wear

FACESHIELD AND HOOD

Comfortable and light weight

FAN/VENTINGAlso available upon request

RATING

65cal/cm2 (Cat 4) designed for extremely hazardous situations

BIBBED TROUSERSFor extra comfortable fitand increased protection

EASY ZIP CLOSURE

For fast fitting

WRIST CUFFS

For snug fit and added safety

LOOSE CUT

For easy fit overexisting work wear

Nomex Arc Flash Suit 65 cal/cm2 For Extra High Risk Applications

Suits

Part No.Size

L XL

90-491-54-L 3

90-491-56-XL 3

OPTIONAL ACCESSORIES

0017-40-XL ArcPro Outer Glove 40cal/cm2

93-33-624-SIZE Slip On Insulated Boots

90-491-HOODFAN-HM Ventilation Fan

TESTING CERTIFICATION

High level of testing for your piece of mind.

November 16, 2005

Date:

Westex Inc.2845 W. 48th PlaceChicago, IL 60632

Client

7.3 oz/yd² Style 301 Khaki

Fabric description

ASTM F1959/F1959M-04 Standard Test Method for Determining the Arc Rating of Materials for

Clothing

Reference Standard

Arc Thermal Performance Value, ATPV = 8.7 Cal/cm² Heat Attenuation Factor, HAF = 74.2%

The arc rating of this material is intended for use as flame resistant clothing for workers exposed to

electric arcs. The material used in this test method are in the form of flat specimens, actual

performance of the complete garment may vary depending on the final design and assembly of the

garment. This test method does not apply to the electrical contact or electrical shock hazard.

Based on the data obtained and analysed in accordance with the latest version of the applicable

standards, the following Arc Rating was calculated.

Summary

Claude MauriceKinectrics [email protected]

Test performed by:

12 inArc Gap: 21

Number of samples analysed: 7 to 11 cal/cm²

Incident Energy Range:

12 inDistance to Fabric:

8.0 kATest current:

Test Parameters:

High Current Test LaboratoryKinectrics Inc., CanadaTest Summary

Panel data and observations of the fabric samples after the arc exposure were collected and summarized

in the attached table. The graphs and statistics on the attached sheets provide more detailed

information to better understand the Arc Rating assigned to this material. The client shall review this full

report, the video recordings of the arc exposure and the photographs of the samples after the test to

determine if the material meets the intended specification.

K-422627-005

Report #

Josh MoodyWestex [email protected]

Contact information

ISO 9001-2000

Refer to pages 6-7 for detailed explanation on rating system.

Page 15: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au 15

SPECIALLY DESIGNED FABRIC

NOMEX IIIA by DuPont (205g/m2), 5 layer construction

HIGH VISIBILITY STRIPES

Positioned on the arms and bottom of the suit toenhance visibility

AVAILABLE IN A GENEROUS NUMBER OF SIZES

Sizes: L / XL / XXL / 3XL / 4XL

TEST: ASTM F1959-05

Arc Rated 44.8cal/cm2 THE SET INCLUDES:

Hood (with helmet), switching coat and leggings.NB: Gloves available separately.

RATING

ATPV: 44.8cal/cm2 (Cat 4)

FACESHIELD IS TESTED TO

Level 4 NFPA (44.8cal/cm²).

Green ‘Light Enhancing Tint’ visor by Paulson.

Worn in conjunction with a helmet (included)

EXTRA LONG LEGGINGS

Designed to cover work boots and protect them from Arc Flash damage

TESTING CERTIFICATION

High level of testing for your piece of mind.

November 16, 2005

Date:

Westex Inc.2845 W. 48th PlaceChicago, IL 60632

Client

7.3 oz/yd² Style 301 Khaki

Fabric description

ASTM F1959/F1959M-04 Standard Test Method for Determining the Arc Rating of Materials for

Clothing

Reference Standard

Arc Thermal Performance Value, ATPV = 8.7 Cal/cm² Heat Attenuation Factor, HAF = 74.2%

The arc rating of this material is intended for use as flame resistant clothing for workers exposed to

electric arcs. The material used in this test method are in the form of flat specimens, actual

performance of the complete garment may vary depending on the final design and assembly of the

garment. This test method does not apply to the electrical contact or electrical shock hazard.

Based on the data obtained and analysed in accordance with the latest version of the applicable

standards, the following Arc Rating was calculated.

Summary

Claude MauriceKinectrics [email protected]

Test performed by:

12 inArc Gap: 21

Number of samples analysed: 7 to 11 cal/cm²

Incident Energy Range:

12 inDistance to Fabric:

8.0 kATest current:

Test Parameters:

High Current Test LaboratoryKinectrics Inc., CanadaTest Summary

Panel data and observations of the fabric samples after the arc exposure were collected and summarized

in the attached table. The graphs and statistics on the attached sheets provide more detailed

information to better understand the Arc Rating assigned to this material. The client shall review this full

report, the video recordings of the arc exposure and the photographs of the samples after the test to

determine if the material meets the intended specification.

K-422627-005

Report #

Josh MoodyWestex [email protected]

Contact information

ISO 9001-2000

Individual Parts

Part No.Size

DescriptionL XL XXL 3XL 4XL

90-490 One size fits most Hood/Faceshield

90-488-54-L 3

Switching Coatonly

90-488-56-XL 3

90-488-58-XXL 3

90-488-62-XXXL 3

90-488-66-4XL 3

Suits

Part No.Size

DescriptionL XL XXL 3XL 4XL

90-488-SUIT-L 3Arc Flash Suit

• Hood (with Helmet)

• Switching Coat

• Leggings

90-488-SUIT-XL 3

90-488-SUIT-XXL 3

90-488-SUIT-XXXL 3

90-488-SUIT-4XL 3

OPTIONAL ACCESSORIES

0017-40-XL ArcPro Outer Glove 40cal/cm2

93-45-645-SIZE Insulated Combat Boots

Nomex Arc Flash Suit 44.8cal/cm2 For High Risk Applications

Refer to pages 6-7 for detailed explanation on rating system.

Page 16: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au16

DEHN PROTECTIVE CLOTHING CAT 3

Part No.Size

Image Description46 48 50 52 54 56 58 48-50 52-54 56-58

DEHN ARC PROTECTION JACKET

D-785769 3

• Arc-fault-tested protective jacket• Flame-retardant zip and hook-and-loop fasteners• Reinforced stand-up collar• Reflective strips and useful pockets• Arc Flash Rating to 33cal/cm2

(NFPA 70E 2012 Cat 3)• Application: High-risk tasks• Not Included: Gloves

D-785770 3

D-785771 3

D-785772 3

D-785773 3

D-785774 3

D-785775 3

DEHN ARC PROTECTION TROUSERS

D-785779 3

• Arc-fault-tested protective trousers• Reflective strips• Pockets available for additional knee pads• Useful cargo pockets and adjustable belt• Arc Flash rating to 33cal/cm2 (NFPA 70E 2012 Cat 3)• Application: High risk tasks• Includes: Flame-retardant fasteners, knee pads and belt• Not Included: Gloves

D-785780 3

D-785781 3

D-785782 3

D-785783 3

D-785784 3

D-785785 3

DEHN ARC PROTECTION COAT

D-785755 3 • Arc-fault-tested protective coat• Flame-retardant zip and hook-and-loop fasteners• Reinforced stand-up collar• Reflective strips and useful pockets• Arc Flash rating to 33cal/cm2 (NFPA 70E 2012 Cat 3)• Application: High-risk tasks• Not Included: Gloves

D-785756 3

D-785757 3

NEW

NEW

NEW

Refer to pages 6-7 for detailed explanation on rating system.

Page 17: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au 17

Part No.Size

Image DescriptionXS S M L XL XXL 3XL 4XL 5XL

MULTI 9 HI-VIZ ARC RATED PARKA V2.0

91-561675-48-50 3

• Arc Flash garment made from a patented Modacrylic fabric (cotton/antistatic/FR blend)

• Waterproof and removable winter liner - antistatic• 10kA/1sec Arc Flash rating• Colour: Hi-Viz yellow/navy

91-561675-52-54 3

91-561675-56-58 3

91-561675-60-62 3

91-561675-64-66 3

ARC RATED SWITCHING COAT - HIGH RISK SWITCHING TASKS (SHORT WORK PERIODS)

91-488-48-S 3

• Arc Flash garment made from patented Proban fabric (100% permanently treated cotton fabric)

• 37cal/cm2 Arc Flash rating - no exposed metal• Dual layer 330g/m2

• Permanent FR and Arc Flash rating• Test reports available on request • Colour: Marine blue

91-488-50-M 3

91-488-52-L 3

91-488-54-XL 3

91-488-56-2XL 3

91-488-58-3XL 3

91-488-62-4XL 3

91-488-64-5XL 3

ARC RATED SWITCHING JACKET - HIGH RISK TASKS (LONGER WORK PERIODS)

91-881198-290-46 3

• Arc Flash garment made from patented Proban fabric (100% permanently treated cotton fabric)

• 37cal/cm2 Arc Flash rating• Dual Layer 330g/m7

• No exposed metal• Colour: Blue/grey

91-881198-290-48 3

91-881198-290-50 3

91-881198-290-52 3

91-881198-290-56 3

91-881198-290-58 3

91-881198-290-60 3

91-881198-290-62 3

ARC RATED SWITCHING JACKET - HI-VIZ FOR HIGH RISK TASKS (LONGER WORK PERIODS)

91-551793-52 3• Arc Flash garment made from a patented Modacrylic

fabric (cotton/antistatic/FR blend)• Ideal as Switching Jacket - antistatic• 10kA/1sec Arc Flash rating• Colour: Hi-Viz yellow/navy

91-551793-54 3

91-551793-56 3

91-551793-58 3

ARC RATED TROUSERS- FOR USE WITH SWITCHING JACKET

91-881201-50-M 3

• Double layer Proban 330g/m2

• Tested to Level 3 ENV50354 (10ka/1sec)• Tested to Cat 3 NFPA 70E (37cal/cm2)• Bibbed trousers also available• Colour: Marine blue

91-881201-52-L 3

91-881201-56-2XL 3

91-881201-58-3XL 3

91-881201-62-5XL 3

ARC FLASH PPE CAT 3

Refer to pages 6-7 for detailed explanation on rating system.

Page 18: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au18

SPECIALLY DESIGNED FABRIC

Rated to 8.7cal/cm2 for the life of the Overalls.

TESTED AT

Cat 2 rated, 8.7cal/cm2

to NFPA ZOE

DOUBLE STITCHED LINES

Ensure extra durability of the overalls

GENEROUSLY SIZED POCKETS:

Two pockets positioned at chest level and two on the sides of the trousers provide plenty of storage options

HEAVY-DUTY ZIPPER

Makes changing in and out of the overalls a breeze.

SPECIALLY DESIGNED FASTENERS

Allow to fasten the trousers "flush" with the boots to avoid accidental tripping

TESTING CERTIFICATION

High level of testing for your piece of mind.

HIGH VISIBILITY STRIPES

Positioned on the top and bottom of the suit toenhance visibility

November 16, 2005

Date:

Westex Inc.2845 W. 48th PlaceChicago, IL 60632

Client

7.3 oz/yd² Style 301 Khaki

Fabric description

ASTM F1959/F1959M-04 Standard Test Method for Determining the Arc Rating of Materials for

Clothing

Reference Standard

Arc Thermal Performance Value, ATPV = 8.7 Cal/cm² Heat Attenuation Factor, HAF = 74.2%

The arc rating of this material is intended for use as flame resistant clothing for workers exposed to

electric arcs. The material used in this test method are in the form of flat specimens, actual

performance of the complete garment may vary depending on the final design and assembly of the

garment. This test method does not apply to the electrical contact or electrical shock hazard.

Based on the data obtained and analysed in accordance with the latest version of the applicable

standards, the following Arc Rating was calculated.

Summary

Claude MauriceKinectrics [email protected]

Test performed by:

12 inArc Gap: 21

Number of samples analysed: 7 to 11 cal/cm²

Incident Energy Range:

12 inDistance to Fabric:

8.0 kATest current:

Test Parameters:

High Current Test LaboratoryKinectrics Inc., CanadaTest Summary

Panel data and observations of the fabric samples after the arc exposure were collected and summarized

in the attached table. The graphs and statistics on the attached sheets provide more detailed

information to better understand the Arc Rating assigned to this material. The client shall review this full

report, the video recordings of the arc exposure and the photographs of the samples after the test to

determine if the material meets the intended specification.

K-422627-005

Report #

Josh MoodyWestex [email protected]

Contact information

ISO 9001-2000

Indura UltraSoft(Day/Night) Overalls

Refer to pages 6-7 for detailed explanation on rating system.

Page 19: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au 19

CAT 2 ULTRASOFT OVERALLS

Part No.SLIM EURO FIT

Image Description87R 92R 97R 102R 104ST 107R 112R 112ST 120ST

90-US502-87R-50-DN 3

• Patented UltraSoft Fabric from Westex Inc. the ultimate in Arc Flash protection.

• Compliant with NFPA 70E• Fabric rated to 8.7cal/cm2

• 237g/m2 fabric weight• Slim Euro fit

90-US502-92R-52-DN 3

90-US502-97R-54-DN 3

90-US502-102R-DN 3

90-US502-104ST-DN 3

90-US502-107R-DN 3

90-US502-112R-DN 3

90-US502-112ST-DN 3

90-US502-120ST-DN 3

ARC FLASH PPE CAT 2

Refer to pages 6-7 for detailed explanation on rating system.

CAT 2 ULTRASOFT SHIRT

Part No.SLIM EURO FIT

Image Description32 34 36 38 39 40 41 42 43 44 45 46 47

90-US500-39-DN 3

• Patented UltraSoft Fabric from Westex Inc. the ultimate in Arc Flash protection

• Compliant with NFPA 70E• Fabric rated to 8.7cal/cm2

• 237g/m2 fabric weight

90-US500-40-DN 3

90-US500-41-DN 3

90-US500-42-DN 3

CLASSIC FIT

Part No. L 2XL 3XL 4XL 5XL

90-US500-43-DN 3

90-US500-44-DN 3

90-US500-45-DN 3

90-US500-46-DN 3

90-US500-47-DN 3

CAT 2 ULTRASOFT TROUSERS

Part No.SLIM EURO FIT

Image Description32 34 36 38 39 40 41 42 43 44 45 46 47

90-US501-32AU-DN 3

• Patented UltraSoft Fabric from Westex Inc. the ultimate in Arc Flash protection

• Compliant with NFPA 70E• Fabric rated to 8.7cal/cm2

• 237g/m2 fabric weight

90-US501-34AU-DN 3

90-US501-36AU-DN 3

90-US501-38AU-DN 3

90-US501-40AU-DN 3

90-US501-42AU-DN 3

90-US501-44AU-DN 3

90-US501-46AU-DN 3

Page 20: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au20

Part No.Size

Image DescriptionXS S M L XL 2XL 3XL 4XL 5XL 6XL

MULTI 7 ARC RATED OVERALLS

91-57262-48-S 3

• Antistatic single layer Modacryl 330g/m2

• Complies with or exceeds 7 European Standards• Tested to Level 1 ENV50354 (4ka/0.5sec)• Calculated to Cat 2 NFPA 70E (8cal/cm2)• Colour: Yellow/navy

91-57262-50-M 3

9157262-54-XL 3

9157262-56-2XL 3

9157262-58-3XL 3

9157262-62-5XL 3

MULTI 9 ARC RATED PARKA - WATER RESISTANT

91-58267-44-46 3• Antistatic rriple layer Modacryl 330g/m2

(with removable winter liner)• Complies with or exceeds 9 European Standards.

‘Won’t Leak’ Guarantee• Tested to Level 1 ENV50354 (4ka/0.5sec)• Calculated to Cat 2 NFPA 70E (8cal/cm2)• Colour: Yellow/navy

91-58267-48-50 3

91-58267-52-54 3

91-58267-56-58 3

91-58267-60-62 3

91-58267-64-66 3

MULTI 9 ARC RATED HI-VIZ BIBBED TROUSERS - WATER RESISTANT

91-58266-48-50-M 3

• Arc Flash garment made from a patented Modacrylic fabric (cotton/antistatic/FR blend)

• Waterproof• 4kA/0.5sec Arc Flash rating• Colour: Hi-Viz yellow/navy

91-58266-52-54-L 3

91-58266-56-58-3XL 3

91-58266-60-62-4XL 3

91-58266-64-66-5XL 3

MULTI 7 ARC RATED BIBBED TROUSERS

91-57264-48-S 3

• Arc Flash garment made from a patented Modacrylic fabric (cotton/antistatic/FR blend)

• 330g/m2 fabric weight - antistatic• 4kA/0.5sec Arc Flash rating• Colour: Hi-Viz yellow/navy

91-57264-50-M 3

91-57264-52-L 3

91-57264-54-XL 3

91-57264-56-2XL 3

91-57264-58-3XL 3

91-57264-62-4XL 3

91-57264-66-5XL 3

91-57264-68-6XL 3

ARC FLASH PPE CAT 2

Part No.Size

Image Description48 50 52 54 56 58 60 62

MULTI 7 ARC RATED TROUSERS

91-57265-50-M 3

• Arc Flash garment made from a patented Modacrylic fabric (cotton/antistatic/FR blend)

• 330g/m2 fabric weight - antistatic• Colour: Hi-Viz yellow/navy• 4kA/0.5sec Arc Flash rating

91-57265-52-L 3

9157265-54-XL 3

9157265-56-2XL 3

9157265-58-3XL 3

9157265-60-4XL 3

9157265-62-5XL 3

Refer to pages 6-7 for detailed explanation on rating system.

Page 21: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au 21

Part No. ColourSize

Image DescriptionS M L XL XXL 3XL 4XL 5XL 7XL

ARC RATED PARKA - WEATHERPROOF PARKA FOR HIGH RISK TASKS

91-37636-52-54 Navy 3 • Double layer NOMEX 265g/m2 + 190g/m2

• Tested to Level 2 ENV50354 (7ka/0.5sec)

• Tested to Cat 2 NFPA 70E (19.6cal/cm2)

91-37636-56-58 Navy 3

91-37636-60-62 Navy 3

91-37636-64-66 Navy 3

ARC RATED OVERALLS - ALL DAY WORKWEAR FOR HIGH RISK APPLICATIONS

91-35950-48-S Orange 3

• Single layer NOMEX 265g/m2

• Tested to Level 2 ENV50354 (7ka/0.5sec)

• Tested to Cat 2 NFPA 70E (9.7cal/cm2)

91-35950-50-M Orange 3

91-35950-52-L Orange 3

91-35950-54-XL Orange 3

91-35950-56-2XL Orange 3

91-35950-58-3XL Orange 3

91-35950-60-4XL Orange 3

91-35950-62-5XL Orange 3

91-35950-66-7XL Orange 3

91-35950-48-S-BL Navy 3

91-35950-50-M-BL Navy 3

ARC FLASH PPE CAT 2

Part No.Size

Image DescriptionXS S M L XL 2XL 3XL 4XL 5XL 6XL

MULTI 7 ARC RATED JACKET

91-155360-48-SM 3 • Antistatic single layer Modacryl 330g/m2

• Complies with or exceeds 7 European Standards

• Tested to Level 1 ENV50354 (4ka/0.5sec)

• Calculated to Cat 2 NFPA 70E (8cal/cm2)

• Colour: Yellow/marine blue

91-155360-50-M 3

91-155360-52-L 3

91-155360-54-XL 3

91-155360-56-2XL 3

91-155360-58-3XL 3

91-155360-66-5XL 3

ARC RATED JACKET - ALTERNATIVE TO OVERALLS OR PARKA

91-351337-46-XS 3

• Arc Flash and flame retardant garment made from DuPont’s patented NOMEX fabric - as used by F1 drivers and fighter pilots

• 19.6cal/cm2 Arc Flash rating• Permanent antistatic and flame

retardant• No exposed metal

91-351337-48-S 3

91-351337-50-M 3

91-351337-52-L 3

91-351337-54-XL 3

91-351337-56-2XL 3

91-351337-58-3XL 3

91-351337-60-4XL 3

91-351337-62-5XL 3

NEW

Refer to pages 6-7 for detailed explanation on rating system.

Page 22: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au22

Part No.Size

Image DescriptionS M L XL

NOMEX BALACLAVA IIIA

0024B-NOMEX One size fits all• NOMEX IIIA double layer flame retardant balaclava• Extra Arc Flash face protection• Double layer front, single layer rear

NOMEX UNDER GARMENTS

0024B-UG-S 3 • NOMEX IIIA single layer flame retardant underwear• Extra Arc Flash protection as worn by F1 drivers• Includes shirt and pants• Sized for tight fit

0024B-UG-L 3

0024B-UG-XL 3

NOMEX SOCKS

0024S-M 3 • NOMEX IIIA single layer flame retardant socks• For use when FR socks are needed• Sized for better fit0024S-XL 3

ARC FLASH PPE

Part No.Size

Image Description24 25 26 38 39 40 41 42 43 44 45 46 48 50 52 53 54 56 57 58 60

NOMEX TROUSERS

91-35502-143-24 3

• Arc Flash and flame retardant garment made from DuPont’s patented NOMEX fabric - as used by F1 drivers and fighter pilots

• 9.7cal/cm2 antistatic and FR rating

• No exposed metal

91-35502-143-25 3

91-35502-143-26 3

91-35502-143-50 3

91-35502-143-52 3

91-35502-143-56 3

91-35502-143-57

91-35502-143-58 3

91-35502-143-60 3

NOMEX SHIRT

91-36162-143-38 3

• Arc Flash and flame retardant garment made from DuPont’s patented NOMEX fabric - as used by F1 drivers and fighter pilots

• No Arc Testing• Permanent antistatic and

FR rating• No exposed metal

91-36162-143-39 3

91-36162-143-40 3

91-36162-143-41 3

91-36162-143-42 3

91-36162-143-43 3

91-36162-143-44 3

91-36162-143-45 3

91-36162-143-46 3

NOMEX BIBBED TROUSERS

91-351149-50 3 • Arc Flash and flame retardant garment made from DuPont’s patented NOMEX fabric

• 9.7cal/cm2 Arc Rating• Permanent antistatic

and FR rating• No exposed metal

91-351149-52 3

91-351149-54 3

91-351149-56 3

91-351149-58 3

Refer to pages 6-7 for detailed explanation on rating system.

Page 23: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au 23

Part No.Size

Image DescriptionS-M L-XL 2XL-3XL

FR WARNING VEST (NO ARC TESTING)

91-57190-S-M 3 • Flame retardant garment made from a patented Modacrylic fabric (cotton/antistatic/FR blend)

• 330g/m2 fabric weight - antistatic• Colour: Hi-Viz yellow/navy• No Arc Flash testing

91-57190-L-XL 3

91-57190-2XL-3XL 3

ARC FLASH PPE HYGIENE KIT

90-HYGIENEKIT N/A

• Single use kit for cleaning and maintaining Arc Flash PPE• Designed to clean and sterilise face shields and headwear• Great product for shared Arc Flash suits or kits• Handy item to keep in switch rooms or with Arc Flash kits

REPLACEMENT LENS

140204RL N/A

• Replacement lens for our ultra popular 10.7cal/cm2 Arc Flash faceshield, the 140204BSDERGOS

• Deep scratches or gouges can effect the flame retardancy and Arc Flash rating of a faceshield

NB: Be sure to regularly inspect and replace faceshield lenses as required

SWEATBAND PR BLACK FOR HARDHATS

93-HMCRHB N/A

• Replaceable sweatband for Hammerhead Hardhat• Increases hygiene for users• Ideal for multiple users/shared hardhats• Colour: Black

KWIK WIPES SACHET 100

94-28700101 N/A

• Alcohol based pre-moisturised wipes• Specially formulated• Streak free• 100 Pack

SWIFT WIPES FOR FACESHIELD

93-SW200 N/A

• Excellent for dirty or greasy faceshields• Designed to ensure crystal clear vision at all times• Great for maintaining hygiene in shared hoods and faceshields• Alcohol based pre-moisturised wipes• Streak free

CHIN STRAP FOR HELMET 4 POINT

140204CS N/A

• Chin strap for Arc Flash helmet• 4 point chin strap• Easy installation• Highly adjustable

PPE BAG BLACK CANVAS

0021PPE650 650mm • Durable black canvas PPE gear bag• 650mm or 900mm lentght available• Durable canvas material and zip - fade resistant• Triple stitched handles• Colour: Black0021PPE900 900mm

ACCESSORIES - ITEMS THAT GO PERFECTLY WITH ARC FLASH PPE

NEW

NEW

Refer to pages 6-7 for detailed explanation on rating system.

Page 24: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au24

CERTIFICATIONSatisfies AS/NZS 4836:2011 and NFPA 70E 2012

SMOKE TINTUV rated light smoke tint

REMOVABLE CHINGUARDFor extra safety and comfort

TESTED TOCat 2 NFPA 70E 2012 (10.7cal/cm2) when worn with 0024-NOMEX

UNIVERSAL ATTACHMENTFits most hardhats / helmets

BSD Bildungs- und Servicezentrum, ErgoS 50 Faceshield with Chin Guard, March 2010

ArcWear.com 13113 Eastpoint Park Blvd, Suite E, Louisville, KY 40223

Phone: 502-314-7158, Fax: 603-457-5960, E-mail: [email protected] 10

Part No. Description

140204BSDERGOSArc Flash 10cal/cm2 Faceshield with Smoke Tint and Removable Chinguard

Arc Flash 10cal/cm2 Faceshield with Smoke Tint and Removable Chinguard

Refer to pages 6-7 for detailed explanation on rating system.

Page 25: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au 25

Part No.Size

Image DescriptionS M L XL XXL

ARC PRO GLOVES

0017-40-XL

• NOMEX ArcPro Arc Flash protective glove ideal to complement Arc Flash Suit

• 40cal/cm2 rating• Designed to fit over electrical insulated gloves• One size only (XL)

3

ARC FLASH GLOVES

D-785796 3• Complex NOMEX leather and rubber

construction - the leading hand protection on the market

• Rated to 45cal/cm2 on the back of hand and 32.8cal/cm2 on palm

• Great feel and dexterity

D-785797 3

D-785798 3

D-785799 3

D-785800 3

NOMEX ARC FLASH HOOD 44.8CAL/CM2

90-490 N/A

• 205g/m2 NOMEX 5 layer construction• Green ‘Light Enhancing Tint’ visor by Paulson• Worn in conjunction with a helmet (included)• Tested to Level 4 NFPA (44.8cal/cm2)

ARC FLASH HELMET - RECOMMENDED TO COMPLIMENT THE FACESHIELD

140201-HRP N/A

• Recommended to compliment the faceshield (Part No. 140204BSDERGOS)

• Using other unrated hardhats will void the Arc Flash rating of our faceshield

• 1000V insulated and flame retardantNB: This is NOT a hardhat, it is for arc protection uses only

ARC SUPPRESSION BLANKET

ASB1.2X1.5M 1.2 x 1.5m • Cat 4 - highest level of Arc Flash protection available

• 5 layer NOMEX construction• 65cal/cm2 Arc Flash rating• Fully approved to NFPA 70EASB1.2X2.4M 1.2 x 2.4m

HYDRATION KIT

HYDRATIONKIT N/A

The Kit Consist of:• 1 x Heavy-duty cool box with hydration message• 1 x Hydration literature (DL)• 4 x Water bottles with hydration message• 1 x HydraTrend strip kit

ACCESSORIES - ITEMS THAT GO PERFECTLY WITH ARC FLASH PPE

NEW

Refer to pages 6-7 for detailed explanation on rating system.

Page 26: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au26

Cat 4 Arc Flash KitsCategory 4 kit to NFPA 70E Arc Flash protection. Designed as an easy to use and easy to store kit for Cat 4 level protection. Tested/rated contents have 44.8cal/cm2 rating.Contains:• 1 x 90-488-SUIT-SIZE• 1 x 0017-40-XL• 1 x 0021PPE650

• 1 x 90-HYGIENEKIT

ARC FLASH KITS

Part No.90-488-SUIT-SIZE

0021PPE650 90-HYGIENEKIT 0017-40-XLL XL XXL 3XL 4XL

CAT4KIT-L 3 3 3 3

CAT4KIT-XL 3 3 3 3

CAT4KIT-2L 3 3 3 3

CAT4KIT-3L 3 3 3 3

CAT4KIT-4XL 3 3 3 3

90-488-SUIT-SIZE017-40-XL 90-HYGIENEKIT0021PPE650

Cat 2 Arc Flash KitsCategory 2 kit to NFPA 70E Arc Flash protection. Tested/rated contents have 8.7cal/cm2 rating minimum.Contains:• 1 x 90-US502-SIZE• 1 x 140201-HRP• 1 x 0021PPE650• 1 x 140204BSDERGOS• 1 x 0584R-KIT-10• 1 x 0024B-NOMEX

Part No.90-US502-SIZE

140201-HRP 140204BSDERGOS 0584R-KIT-10 0024B-NOMEX 0021PPE650M L XL

CAT2KIT-M 3 3 3 3 3 3

CAT2KIT-L 3 3 3 3 3 3

CAT2KIT-XL 3 3 3 3 3 3

90-US502-SIZE

140201-HRP 140204BSDERGOS 0584R-KIT-10 0024B-NOMEX 0021PPE650

Refer to pages 6-7 for detailed explanation on rating system.

Page 27: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au 27

LOCKOUT KITS

Part No. Image Description

BASIC LOCKOUT KIT

ULO-01000

• 2 x Mini CB / Residential Lockouts• 1 x Industrial Lockouts• 1 x Pen• 1 x Dielectric Hasp• 2 x Non-Conductive Lock• 10 x Lockout Tags

PERSONAL LOCKOUT KIT

ULO-02000

• 1 x Vinyl Coated Hasp Small• 2 x Miniature Circuit Breaker Lock Out• 1 x Universal MCB• 1 x Universal Fuse Holder• 1 x Jacket Padlock with Long Shackle• 1 x EXT Bag• 1 x Multipurpose Cable Lockout

• 1 x Out of Service Tag• 1 x Do not Operate Tag• 1 x AC Test Screwdriver

3.5 x 190mm (ACTEST3)• 1 x CABAC Pen (CABACPEN)• Nylon Cable Tie 200 x 4.8mm UV

4 x Black (CT200BK)

PREMIER LOCKOUT KIT - FOR LARGER CONTRACTORS

ULO-ES-EP01

• 1 x CB Lockout Pack with all types of Lockouts

• 3 x Mini CB Lockouts• 2 x Universal CB Lockouts• 1 x Cable Lockout• 1 x Pen• 1 x 3 Lock Dielectric Hasp

• 1 x 6 Lock Dielectric Hasp• 2 x Non-Conductive Lock• 5 x Lockout Tags• 1 x Screwdriver• 1 x Premium Hasp• 1 x Large Industrial Breaker

Lockout

INDUSTRIAL LOCKOUT KIT

ULO-ES-EP02

• 1 x CB Lockout Pack with all types of Lockouts

• 3 x Mini CB Lockouts• 2 x Universal CB Lockouts• 2 x Cable Lockouts• 1 x Pen• 2 x Pack of Zip Ties• 4 x 3 Lock Dielectric Hasp• 1 x 6 Lock Dielectric Hasp• 5 x Non-Conductive Lock

• 20 x Lockout Tags• 1 x Screwdriver• 1 x Premium Hasp• 1 x Large Industrial Breaker Lockout• 2 x Steel Locks Large• 5 x Steel Locks Small• 1 x Gas Cylinder Lockout• 1 x Plug and Lead Lockout• 1 x Electrical Panel Handle Lockout• 4 x Speciality Lockouts

LOCKOUT STATIONS - 5, 10 AND 20 PERSON STATIONS

ULO-ES-5L-2P-Y 5 Person (5 Locks, 3 Hasps, 10 Tags)

ULO-ES-10L-1P-Y 10 Person (10 Locks, 4 Hasps, 10 Tags)

ULO-ES-20L-2P-Y 20 Person (15 Locks, 7 Hasps, 20 Tags)

5 Person

20 Person10 Person

NEW

Page 28: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au28

LOCKOUT KITS

Part No. Features Image Description

STEEL HASP - SCISSOR LOCKOUT HASP

ULO-ES-SLH-42Pry-resistant steel toughness to combat tampering

• Traditional style lockout/tagout hasp for up to 6 locks• Nylon body and vinyl coated to avoid accidental

sparking• Scissor mechanism• Anti-corrosion

CABLE LOCKOUT 2M (STEEL CABLE)

ULO-ES-PMC-2C Colour: Red

• Universal and fully adjustable cable lockout fits many different items and can be used for almost anything

• 2m steel cable• Features a Danger label

UNIVERSAL LOCKOUTS FOR CIRCUIT BREAKERS

ULO-1-MCBMini CB Lockout for Standard Domestic Breakers

• Universal Circuit Breaker Lockout device used to lockout any small, mini or residential sized circuit breakers

• Universal fit to suit most CB’s you will come across in the field

• Features a Danger labelULO-1-ES-UBL

Universal CB Lockout for Industrial Breakers

UNIVERSAL LOCKOUTS FOR CIRCUIT BREAKERS

ULO-PINCOMBO-CBL

Consists of:Pin in CBLPin out CBLPin out wide CBL

NEW• Push button installation - does not require any tools• A padlock should be applied to lockout the MCB

CB LOCKOUT AL

ULO-2-MCB Colour: Gold• Used for miniature circuit breakers• Made from Aluminum• Size: (h)24 x (w)17 x (d)8mm

TAGS - LOCKOUT TAGS FOR ANY APPLICATION (DO NOT OPERATE)

ULO-ES-TAGS149 Heavy-duty 10 pack of tags • Lockout/tagout identification tags - double sided• Do Not Operate label on one side and Ownership

label on other side• Resilient to grease, water and general wear and tear

ULO-ES-TAG Heavy-duty individual tags

ULO-ES-ST08 Disposable individual tags

APPLIANCE LOCKOUT PLUGS AND LEADS

ULO-CLO-E

• Fantastic appliance or hose lockout solution for locking out inactive or decommissioned machinery

• Quick and easy application• Ownership and Danger Label

GATE VALVE LOCKOUT - SUITS GAS BOTTLES AND GATE VALVES

ULO-ES-GVCL Small (portable gas bottle size) • Small gas valve style lockout, suitable to lockout any small portable gas bottle (with gate valve)

• Nylon construction• Colour: Red• Danger/Ownership label

ULO-ES-AGV Adjustable (fits most sizes)

GAS CYLINDER LOCKOUT - LOCKOUT AND FILL LEVEL INDICATOR

ULO-ES-CLO-GRNFULL Green (full) Lockout• Universal gas bottle lockout device designed to fit the

tops of most gas bottles• Colour: Yellow

ULO-ES-CLO-RDEMPTY Red (empty) Lockout

NEW

Page 29: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au 29

LOCKOUT KITS

Part No.Colour

Image DescriptionBlack Blue Green Orange Red Yellow

DIEELECTRIC LOCK NYLON - KA

ULO-ES-DEL-KA-BL 3 • Lockout padlock with all nylon construction for use in all areas

• Nylon body and shackle• Metal barrel• Colour: Available in blue, green, orange, red and

yellow

ULO-ES-DEL-KA-GN 3

ULO-ES-DEL-KA-OR 3

ULO-ES-DEL-KA-RD 3

ULO-ES-DEL-KA-YL 3

LOCKOUT SETS PADLOCKS KEY DIFFERENT (WITH MASTER KEY)

ULO-ES-PLSPKDM5BLK 3

• Set of 5 dielectric locks with master key - all locks are keyed differently

• Colour: Available in various colours with glow-in-the-dark Danger Label

• Nylon body and shackle

ULO-ES-PLSPKDM5BLU 3

ULO-ES-PLSPKDM5GN 3

ULO-ES-PLSPKDM5OR 3

ULO-ES-PLSPKDM5RD 3

ULO-ES-PLSPKDM5YEL 3

LOCKOUT SETS - 10 PADLOCKS ALL ACCESSIBLE BY ONE KEY

ULO-ES-PLSPKAM10BK 3• Set of 10 dielectric key alike locks - all

locks share the same key cut, making keys interchangeable

• Colour: Available in various colours with glow-in-the-dark Danger Label

• Nylon body and shackle

ULO-ES-PLSPKAM10GN 3

ULO-ES-PLSPKAM10OR 3

ULO-ES-PLSPKAM10RD 3

ULO-ES-PLSPKAM10YE 3

DIELECTRIC LOCK NYLON - KD

ULO-ES-DEL-KD-BLUE 3 • Dielectric padlock for lockout use• Nylon body• Nylon hasp• Metal barrel• Colour: Available in blue, green, orange, red and

yellow

ULO-ES-DEL-KD-GN 3

ULO-ES-DEL-KD-OR 3

ULO-ES-DEL-KD-RED 3

ULO-ES-DEL-KD-YEL 3

SET OF 2 PREMIUM HASPS

ULO-ES-HASPPREMIUM 3

• Padlock style suitable for up to 4 locks• Includes 2 Hasps (1 thin shackle, 1 thick)• Colour: Yellow• Features a Danger label

LOCKOUT STEEL PADLOCK LONG SHAKLE

ULO-ES-PLS3 N/A

• Lockout padlock with all metal construction for extra strength and durability

• Steel body and shackle• Danger label and Ownership label

DIELECTRIC HASPS 3 LOCK

ULO-ES-EHASP33 3-Lock 3

• All nylon, non-conductive lockout hasp• Fits up to 3 locks• Non sparking and non conductive

• Lightweight and durableULO-ES-EHASP66 6-Lock 3

NEW

Page 30: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au30

COMPONENTS FOR LOCKOUT KITS

Part No. Image Description

LOCKOUT STATION SMALL

ULO-ES-810-Y• Lockout station designed to cover the lockout needs of up to 5 people• Wall mounted• Can accommodate: 5 locks, 3 hasps and 10 tags (optional accessories)

LOCKOUT COMBO CB 5 OFF

ULO-ES-CBF-COMBO5• Handy 5 pack of various Circuit Breaker lockout devices• Suits most CB’s on the market• Large industrial breakers through to small mini toggle breakers

LOCK BOX METAL

ULO-ES-GLBLOCKBOX• Metal construction lock box for group lockout work• Red and easily identifiable• Multiple lockout loops for multi-use systems

LOCKOUT BAG

ULO-ES-LE-POUCH• Quality zip pouch large enough to hold basic

lockout essentials• For the electrical contractor

PNEUMATIC LOCKOUT DEVICE LARGE

ULO-ES-LPLO

• Pneumatic Lockout Device for cables, air lines or pneumatic devices• Sturdy nylon body construction• Designed to lockout and avoid use of pneumatic devices• Use in conjunction with lockout padlock

MULTI-PURPOSE STAINLESS LOCKOUT

ULO-ES-MMCL• Handy stainless steel lockout to suit various applications• Widely adaptable to suit many lockout requirements• Strong and durable stainless steel construction

PNEUMATIC LOCK OUT LARGE

ULO-SDNOB

• Nylon weighted visual lockout indication device• For OH lines only• To be applied if service fuse is pulled• Durable yellow nylon

NEW

NEW

Page 31: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au 31

HARNESSES AND HEIGHT SAFETY KITS

Part No. Applications/Inclusions Image Description

DURA-FLEX HARNESS MED/LARGE

MSS-M1020073

• Construction and maintenance• Elevated work platforms• Scaffolding• Ladder safety systems• Confined space rescue

• Miller Duraflex fall arrest and confined space harness - one size only

• Suitable for working on elevated work platforms and scaffolding

• Includes confined space webbing loops• Adjustable leg, chest and shoulder straps for a better fit

ECONOMY ROOFERS SAFETY KIT

17-HS-DLER-BP

Kit includes:1 x Hi-Safe FH 50 full body harness1 x 15m of 11mm rope with sewn eyelet and steel screw gate karabiner1 x Personal energy absorber with rope grab and screw gate karabiner1 x 1500 mm round sling1 x Back pack

• Designed by industry professionals and tested in the field to meet the day to day requirements of roof workers

• All components have been carefully selected for durability and quality ensuring longevity of service while keeping budgets in check

HI-SAFE FH50 FULL BODY HARNESS

17-HS-FH50

A price point full body harness with all mandatory safety features including confined space retrieval attachment points

• Front and rear free fall arrest attachment points• Confined space retrieval attachment points• Breathable rear mesh panel keeps the harness in shape• Quick and easy to don and adjust• Fully adjustable, multi size fit• Certified to AS/NZS 1891.1:2007• Oil, grease and water repellent webbing• Optional permanently attached lanyard also available• Customised labeling available - conditions apply

FERNO TOWER 5 HARNESS

17-VHITOW5-MAn exceptionally comfortable and stable harness for suspended tower work

• Comfortable padded and stable seat with lumbar support• Large, low set pole strap attachment points• Rear, dorsal free, fall arrest extension strap• Front free fall arrest attachment points• Reflective and photo luminescent for exceptional visibility• Quick connect adjustable leg buckles• Rear gear loops• Stainless steel componentry• Neoprene covers on all upper metal buckles• Certified to AS/NZS 1891.1:2007• Sizes: XS, S, M, L and XL (Conditions apply for XS and X)Front Vew Back Vew Back Vew

(High Visibility)

NEW

NEW

NEW

Page 32: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au32

LANYARDS

Part No.Length (M)

Image Description1.2 1.5 1.8 2.0 2.3 2.4 2.7 2.8

POLE STRAP FOR RESCUE KIT

17-VAIPOLE22.8NZBLD 3

• Padded strap protection increases product life in service

• Dual action D-hooks on both end for ease of use• Length: 2.8m• Colour: Blue

MILLER ENERGY ABSORBING WEBBING LANYARDS

MSS-L11WEC1.5 3• Constructed from 35mm polyester webbing• Integral compact energy absorber smoothly expands• 19mm double acting hooks at each end• Miller by HoneywellMSS-L11WEC2.0 3

MILLER ENERGY ABSORBING STRETCHTOP LANYARD

MSS-L11SEC1.5 3• Featuring an elastic inner core• Will not drag on ground when not in useMSS-L11SEC2.0 3

MILLER ENERGY ABSORBING DOUBLE WEBBING LANYARDS

MSS-LD18SEC2.0• Miller energy absorbing stretchtop lanyard• Featuring an elastic inner core• Will not drag on ground when not in use

3

FALL ARREST LANYARD WITH SCREWGATE CARABINEER

17-HS-LYS100 3

• 2m long fall arrest lanyard with screwgate carabineer

• Energy absorbing section• Colour: Orange

ELASTIC LANYARD

17-HS-LYS110EL 3

• Elastic 2m fall arrest lanyard for height safety use• Elastic construction keeps the 2m of webbing

bunched up• Avoids trip hazards and messy work space

MILLER POLE STRAPS

MSS-136.1S 3 • The Miller pole strap range is fully adjustable allowing for various work positioning application

• Pole strap adjuster located on the hook - change length easily

• Equipped with protective sleeve to maintain life of the strap

• Certified to AS/NZS 1891.1-2007

MSS-138.1S 3

MSS-139.1S 3

Page 33: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au 33

KARABINERS AND ROOFLOK

Part No. Image Description

ROOFLOK TEMPORARY ROOF ANCHOR POINT

17-FWWRF

• Suitable for corrugated iron or tile roofing• Full range of motion retained• Light and compact, Ferno’s ROOFlok is the perfect temporary anchor system

for moving from job to job• Supplied standard with 19mm double acting hooks at each end• Fitted with ANCHORsafe, a 360º swivel attachment that allows

uninterrupted work access and which also absorbs shock load during a fall

TRIPLE ACTING FORGED STEEL KARABINER

MSS-91326Triple acting 18mm gate - 3.0 tonne

• Manufactured from forged steel• Triple acting• 30kN strength• 3 tonne and 4.5 tonne availableMSS-91328

Triple acting 23mm gate - 4.5 tonne

SCREW GATE ALLOY STEEL KARABINER

MSS-501

• Karabiner with 16mm opening• Made from forged steel• Featured a screw gate• 22kN strength

KARIBINER DOUBLE ACTING - 3500KG - 65MM

MSS-502

• Karabiner with 65mm opening• Made from drop forged alloy• Double action - twist to open• 35kN strength

SCAFFOLD HOOK - 64MM OPENING

MSS-M1030003• Scaffold hook with a 64mm opening• Made from forged alloy steel• Double acting

Page 34: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au34

1000V INSULATING GLOVESInsulating Gloves Class 0 (1000V)

LV RESCUE HOOK(LV - tested to 15kV)

EVERYDAY BRILLIANT BEAM TORCHDesigned to keep light from shifting when bumped. Built-in hanger ring allows hands-free use

FIRST AID BOOKLETA basic information booklet covering the management of common injuries in line with accepted best practice protocols.

‘ISOLATE HERE’ SIGN

BURNS DRESSINGSterile protective dressingfor First Aid applications.Size: 25.4cm x 76.2cm(10 x 2.5ft)

HEAVY-DUTY VINYL BAG WITH A SHOULDER STRAPLightweight but heavy-duty this bag, with high visibility letters featured at the front, is ideally suited to store a rescue kit

FIRE BLANKETEasy to pull outfire blanketSize: 1.2 x 1.8m

LV Switchboard Rescue Kit - Designed for LV Rescue from Switchboards

NOTE: Components of all kits are available separately. Refer to General Safety section for details.

LV RESCUE INSTRUCTIONAL DVD(Optional addition to the kit)

Part No. Description

01002-LVSK LV Switch Rescue Kit

01002DVD LV Rescue Instructional DVD (DVD only)

01002-LVSK-AS LV Switchboard Rescue Kit With AS2225 Gloves

Maintain a safe work environment. We recommend regular 6 month HV testing of these products. Contact us for information on testing.

Page 35: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au 35

Part No. Inclusions Image Description

LV POLE TOP RESCUE KIT COMPLETE

MSS-PTR-KIT1

Kit Contains:1 x CPR Card (current regulations)1 x Rescue belt1 x LV insulating gloves1 x Riggers gloves1 x 1.2m Anchor strap1 x 16m x 11mm rescue rope with decent device1 x Parrot beak cutters1 x Combination pliers1 x Hook style webbing knife

• Suitable for use in NSW on all pole top electrical installations

• Supplied with AS2225 1000V Gloves

HV RESCUE KIT

01002HV

Kit Contains:1 x 26,500V Insulating gloves1 x HV Rescue hook1 x LV Rescue hook1 x Torch1 x Fire blanket (1.8m x 1.2m)1 x ‘Isolate Here’ Sign1 x Burns dressing1 x First Aid Hints booklet

• Designed for switchboard rescue above 1000V• Suitable for all states in Australia• Suitable for AusGrid or AusGrid contractors

POLE TOP RESCUE KIT

01001-PRK

Kit Contains:1 x 1000V Insulating gloves1 x 30m Rope1 x Pole strap1 x Body belt tool pouch1 x Knife1 x Parrot beak cutters

• Designed for pole top rescue of electrical workers• Supplied in a bright yellow fibreglass box• Kit contains safety rope, snap hooks, body belt and more• Items also available individually

TOWER RESCUE KIT - RESCUE KIT FOR TOWER WORKERS

17-VKIT-FTRK

Kit Contains:1 x Yellow storage bag1 x 65m rope with eye and karabiner1 x FDU100 Rescue descender1 x 50mm x 1200mm sling2 x 25mm x 1200mm round sling1 x Rescue knife with extender and karabiner1 x Neck brace1 x Mechanical Advantage Retrieval System

• Designed by industry professionals and tested in the field to meet the day to day requirements of workers at heights

• Quality components are durable ensuring longevity of service

• 65 metres of rope with karabiner and slings• Includes a neck brase and is supplied in a yellow

storage bag

RESCUE KITS

NOTE: Components of all kits are available separately. Refer to General Safety section for details.

Maintain a safe work environment. We recommend regular 6 month HV testing of these products. Contact us for information on testing.

Page 36: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au36

Insulated 1000V - QuickFit Rubber Overboot

HIGH FITEnsures extra comfort and protection against elements

QUICK FITIngenious rear entry design ensures the boot is quick and easy to fit and remove

DURABLE AND GRIP SOLEVulcanized rubber sole for maximum grip. Fuel and oil resistant

PURPOSE DESIGNIdeal for personnel who have to continually enter and exit hazardous areas. Yellow dielectric compound shaft. Seamless construction and kick off lug

MEETS THESE SAFETY STANDARDSElectrically Insulating Footwear EN 50321 Class 0Dielectric Footwear ASTM F1117

Part No.Size

M L XL

785405OB-M-39-42 3

785405OB-L-43-45 3

785405OB-XL-46-48 3

Page 37: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au 37

BOOTS

Part No. Size Image Description6 6.5 7 7.5 8 8.5 9 9.5 10 10.5 11 12 13

INSULATED SLIP-ON BOOTS BEIGE

93-33-624-6 3

• Tested to 14kV under ASTM Standards

• ASTM F 2413-05 Clause 5.5 Tested• 14000V at 60Hz for 1 minute• No metal

93-33-624-6.5 3

93-33-624-7 3

93-33-624-7.5 3

93-33-624-8 3

93-33-624-8.5 3

93-33-624-9 3

93-33-624-9.5 3

93-33-624-10 3

93-33-624-10.5 3

93-33-624-11 3

93-33-624-12 3

93-33-624-13 3

INSULATED SLIP-ON BOOTS BROWN

93-33-626-6 3

• Tested to 14kV under ASTM Standards

• ASTM F 2413-05 Clause 5.5 Tested• 14000V at 60Hz for 1 minute• No metal

93-33-626-6.5 3

93-33-626-7 3

93-33-626-7.5 3

93-33-626-8 3

93-33-626-8.5 3

93-33-626-9 3

93-33-626-9.5 3

93-33-626-10 3

93-33-626-10.5 3

93-33-626-11 3

93-33-626-12 3

93-33-626-13 3

INSULATED COMBAT BOOTS

93-45-645-6.5 3

• Tested to 14kV under ASTM Standards

• ASTM F 2413-05 Clause 5.5 Tested• 14000V at 60Hz for 1 minute

93-45-645-7 3

93-45-645-7.5 3

93-45-645-8 3

93-45-645-8.5 3

93-45-645-9 3

93-45-645-9.5 3

93-45-645-10 3

93-45-645-10.5 3

93-45-645-11 3

93-45-645-12 3

93-45-645-13 3

Part No.Size

Image DescriptionAU 6/7 10 10.5 11 12 13

EU 41 44 45 46 47 48INSULATED RUBBER GUMBOOT - 1000V CLASS 0

785405-41-6-7 3• Approved to:

EN ISO 20345, EN 13287 SRA, EN 20345E, EN 20345E, EN ISO 20345 ASTMF1117, PPE DIR 89/686/EEC, EN50321

• 1000V Rated• Colour: Yellow

785405-44-10 3

785405-45-10.5 3

785405-46-11 3

785405-47-12 3

785405-48-13 3

Page 38: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au38

Part No. Colour Image Description

SAFETY GOGGLES SPARTA CLEAR

93-149SCCU Clear

• Level 2 impact rated lab style goggle, vented design with antifog for complete protection from all angles

• AS/NZS1337.1 approved• Clear with elastic strap

SAFETY GOGGLES ALPHA

93-01SCCU Clear

• Site visitor / laboratory style safety glasses• Medium impact rated• AS/NZS1337.1 approved• Clear lenses and frame

SAFETY GLASS RADAR CLEAR

93-14SBGC Grey/Clear

• Premium style safety glasses with adjustable arms• Medium impact rated• AS/NZS1337.1 approved• Clear lenses and grey frame

SAFETY GLASSES COBRA CLEAR

93-12SCC Clear

• Basic style indestructible safety glasses• Medium impact rated• AS/NZS1337.1 approved• Clear lenses and frame

SAFETY GLASSES ATLANTIC OVERSPEC

93-387SMBCA Black/Clear

• Advanced sunglasses style safety glasses• Modern look and feel• Medium impact rated• AS/NZS1337.1 approved

SAFETY GLASSES SABER RED/ SMOKE MIRROR

93-900SBRRM Red Iridium

• Modern look and feel - available in smoke or red colour• Medium impact rated• AS/NZS1337.1 approved

93-900SBSD Smoke

SAFETY GLASSES BLACK/RED OR DARK/WHITE

93-0105SBRM Black/Red • Advanced sunglasses style safety glasses• Modern look and feel• Medium impact rated• AS/NZS1337.1 approved93-0105SWSMD Dark/White

SAFETY GLASSES

93-0105SBRM

Page 39: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au 39

Part No.Misc

DescriptionImage Description

HAMMERHEAD HARD HAT

93-HM2ATY Yellow • Approved to AS1801 Type 1 - Industrial• Replaceable sweatband• Available colours: Yellow/White93-HM2ATW White

DUST MASK

93-P2 20 per Box• Suitable for general dust, dirt and air pollution• Available with or without valve

93-P2V10 per Box (with valve)

JAVELIN EAR MUFFS CLASS5 -26DB

93-M06 Yellow• Rated to class 5 (26dB)• Approved to AS/NZS 1270

DISPOSABLE EAR PLUGS

93-DBOSS27200 per box (Uncorded)

• Rated to class 5 (27dB)

93-DBOSS27-C100 per box (Corded)

RIGGERS GLOVES

0010-M M• Designed for mechanical hand protection• Made from cow hide leather• Colour coded cuff (by size)• Double stitching - extra durable

0010-L L

0010-XL XL

0010-XXL XXL

RED LEATHER GLOVES EXTRA LONG

0013-RWG Red

• Extra long for extra spatter protection• Leather• Colour: Red• Heat resistant

TOP GLOVE SAHARA

0102-09 Size 9 • Nitrile dipped cotton protection gloves• Snug fit• Strong and durable0102-10 Size 10

BODY BELT FOR RESCUE KIT

17-VAIPOLEBELT

• Designed for use with pole top rescue kit• For rescue application ONLY• D-shackles for Pole Strap attachment• Adjustable size

HI-VIZ VEST

91-SV1510VEST

• Quality Hi-Viz vest for work and construction site applications• Not for live electrical work• Reflective tape• One size fits most

GENERAL SAFETY

SIZE

SIZE

Page 40: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au40

Part No. Image Description

FIRST AID HINTS BOOKLET

010104-FAHINTS

• Handy hints for First Aid• CPR instructions• Ideal size for glove box or tool box

MULTI-TRAUMA DRESSING

01011-MTD

WARNING: Never use dressings other than multi-trauma dressings to treat burns• Supplied in LV Rescue Kit for burns treatment• Use: Treating burns (including electrical burns)• Size: 25.4 x 76.2cm• Special non-stick dressing for multiple injuries and burns

LV RESCUE HOOK

01015-LV-RH

• Insulated hook for low voltage rescue• Nylon construction• Type tested to 15kV• Designed for easy rescue

ISOLATE SIGN

1016-IS• Sign designed for identifying isolation point• Should be hung at isolation switch before beginning

any work live or near live parts

EMERGENCY CAR TORCH

1018TORCH

• Emergency car torch with - buzzer - flashing emergency lights - magnet - seat belt cutter

RESCUE BAGS - LV (BAG ONLY)

01010-YRB

• Bag for LV Rescue Kit• Durable vinyl material• Colour: Available in orange or yellow• Reflective print

01010-OR

RESCUE BAG - HV (BAG ONLY)

01010-YRB-HV• Waterproof and heavy-duty HV Rescue Bag with reflective writing• Colour: Fluorescent yellow

GENERAL SAFETY

Page 41: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au 41

TRAFFIC CONTROL AND FIRE FIGHTING EQUIPMENT

Part No.Misc

DescriptionImage Description

PORTA-CONE COLLAPSIBLE TRAFFIC CONE

17PORTA450 450mm • Patented collapsible traffic cone designed for applications where storage space is at a premium

• Day/Night reflective strips• Collapsible into flat base• Includes flashing safety light

17PORTA700 700mm

17PORTA900 900mm

ROAD SAFETY KIT

010102-RSK

• First Aid Kit • Collapsible Traffic Cones• Riggers Gloves• Glow Sticks• Hand Wipes• Hi-Viz Vest• Vehicle Torch (with seat belt cutter and glass breaker)

REGA 16 LITRE FIRE FIGHTING KNAPSACK ACCESSORIES

MSS-KS-ACC-P3-CB Vehicle bracket to suit REGA

Knapsack • Backpack stores 16 litres of water and is supplied with a hand pump - for putting out spot fires

• Stored on all utility vehiclesMSS-1323Red canvas cover to suit REGA

Knapsack

16 LITRE FIRE FIGHTING KNAPSACK WITH CONTINUAL WATER JET

MSS-TPFK0016LYE • Robust yellow coloured tank to help resist UV damage• Unique pump grip and handle reduces operator fatigue• Lid contains filter and the hose features an adjustable nozzle• Convenient hose and lance storage, with handle for ease of

carrying• Conforms to AS1687 Standard

MSS-TASFF0016 Optional Mounting Bracket

FIRE EXTINGUISHERS ABE POWDER TYPE

01014EX1.0 1kg without hose

• Suitable for multiple applications• ABE Powder type• Suitable for cars and buildings• Available with or without hose

01014EX1.0-HOSE 1kg with hose

01014EX2.5 2.5kg

01014EX4.5 4.5kg

01014EX6.0 6.0kg

01014EX9.0 9.0kg

FIRE FIGHTING RAKE/HOE

MSS-100942• Hardened blade and rake• Perfect for creating fire breaks and clearing foliage

WALL AND VEHICLE MOUNTING BRACKETS

01014EX9.0-VMB for 6-9kg extinguishers

• Heavy-duty vehicle mounting bracket for fire extinguishers• Steel reinforced• Suitable for all vehicles010104EX4.5-VMB for 2.5-4.5kg extinguishers

FIRE BLANKET

01014-FB • Fire blanket also available in the LV Rescue Kit• 1.2 x 1.8m

Page 42: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au42

Part No. Image Description

GLOVE BOX SIZE FIRST AID KIT

MSS-JBGBK

• 10 x Adhesive dressing strips• 1 x Micropore tape 1.2cm• 1 x Saline eye wash 15ml• 1 x Bandage 7.5cm• 1 x Sterile eye pad• 1 x First Aid guide• 1 x Scissors• 1 x Tweezers

• 1 x Disposable gloves• 2 x Antiseptic swabs• 12 x Safety pins• 1 x Triangular bandage• 1 x Wound dressing #13• 1 x Gauze swabs 7.5x7.5cm• 1 x Small dressing• 1 x Crepe bandage 5cm

WORKPLACE FIRST AID KIT SUITABLE FOR BUSINESSES 1-25 PEOPLE

MSS-JBMPCF

• 50 x Adhesive dressing strips• 1 x Aeropore tape 1.25cm• 1 x First Aid guide• 2 x Triangular bandages 110cm • 1 x A/Steel scissors• 1 x S/Steel forceps• 2 x Sterile eye pads• 5 x Saline eye wash 15ml• 2 x Gauze swabs 7.5cm pk 3• 2 x Combine pads 10 x 10cm• 1 x Disposable gloves Pk 2• 2 x Small dressings• 2 x Medium dressings• 1 x Bandage 2.5cm• 1 x Bandage 5cm• 1 x Bandage 7.5cm

• 1 x Bandage 10cm• 1 x Crepe bandage 5cm• 1 x Crepe bandage 7.5cm• 1 x Wound dressing #13• 1 x Wound dressing #14• 1 x Wound dressing #15• 10 x Antiseptic wipes• 1 x Basic dressing pack• 1 x Thermo foil blanket• 1 x Resuscitation face shield• 100 x Cotton buds• 1 x Bio-Hazard bag• 1 x Instant ice pack• 12 x Safety pins• 1 x Splinter probe disposable

SNAKE BITE KIT

MSS-JBSB

• 1 x Triangular bandage• 1 x Thermo foil blanket• 1 x Resuscitation face shield• 1 x Aeropore tape 1.25cm

• 1 x Disposable gloves• 2 x Bandages 7.5cm• 1 x Snake bite First Aid information

FIRST AID KIT SMALL

010104KSML

• 1 x Plastic adhesive strips, 72 x 19mm 20 pack

• 1 x Assorted plastic adhesive strips 20 pack

• 1 x Disposable large gloves 2 pack• 1 x Sterile antiseptic alcohol

wipe/swab• 1 x Sterowipe - antiseptic wipe/swab,

non-sting• 1 x White conforming bandage, 5cm• 1 x Double ended cotton tips, 7.5cm

100 pack• 1 x Disposable CPR face shield• 1 x Emergency first aid information

booklet• 1x Sterile eye pad

• 1 x Eye wash ampoule, 30ml• 1 x Steel forceps, 8cm• 1 x Sterile non-adherent dressing,

10cm x 7.5cm• 1 x Hypo-allergenic white paper

tape, 1.25cm x 9m• 2 x Povi iodine swabs• 1 x Rescue/Thermal Blanket Silver

Space• 1 x Card of 12 assorted safety pins• 1 x Steel scissors, 9cm• 5 x Disposable splinter probe, 4cm• 1 x Triangular bandage, 110cm

SHARPS KIT

MSS-JBSK• 5 x Gloves (pairs)• 1 x Sharps Container• 1 x Tongs

FIRST AID KITS

NEW

Page 43: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au 43

Part No. Usage Image Description

MINI TRUCK KIT SPILL KIT

MSS-SKGPT

SPILL TYPE: Designed to recover coolants, solvents, oils, degreasers, blood and water (not aggressive acids)APPLICATION: Indoor, outdoor - wherever liquids are stored, handled, used and spilt. Carry in cars, trucks, vans and delivery vehiclesABSORBENT CAPACITY: 87 litres

• For those who carry small liquid volumes but still require a spill kit• Contains variety of EnvirosorbTM premium polypropylene oil and fuel only

absorbents and organic Global Peat ground and floor absorbent• EnvirosorbTM is water repellent and recovers up to 20 times its own weight

in oil• Global Peat is easy to use and recovers up to approx. 5 times its own

weight in oil• Includes laminated re-order form and operating instructions• UV stabilised, colour coded labels fitted to front of bag• Customise by adding/removing/swapping components• Supplied in a highly visible ‘safety yellow’ water resistant carry bag• Hook and loop grip closure allows for easy opening

UNIVERSAL SPILL KIT/GENERAL PURPOSE SPILL KIT

MSS-SKHMT

SPILL TYPE: Oil, fuel, diesel, petrol, solvents and other petroleum productsAPPLICATION: Outdoor areas around mine sites, drilling rigs and truck stops. Components designed for harsh conditionsABSORBENT CAPACITY: 21 litres

• Designed for those who transport general liquids of a non-dangerous type• Variety of general purpose floorsweep and polypropylene all liquid

maintenance absorbents• Polypropylene able to recover up to 20 times its own weight in liquid• Supplied in a sky blue canvacon bag with a hook and loop grip seal• Includes resistant label, laminated re-order form and operating instructions

UNISORB PAD 32CM X 28CM

MSS-GBL-25SRCG

SPILL TYPE: Absorbs most acids, bases, coolants, paints, solvents, oils and hazardous chemicalsAPPLICATION: Use wherever chemicals are stored handled and splitABSORBENT CAPACITY: Up to 14.5 litres per pack of 50 Pads

Ideal for chemical processing plants, paint and panel shops, chemical storage and handling facilities, transport warehouses, food and beverage processing plants, printing and automotive workshops

• Made from 100% UnisorbTM compressed meltblown polypropylene• Can absorb up to 20 times its own weight in liquid• Does not degrade or chemically react with the absorbed liquid • Ideal for wiping up smaller spills• High absorbency to weight ratio = lower transport and disposal costs• Non-allergenic, non-hazardous and dust free• Reduces potential slip hazards and improves safety in the workplace• Simple to use without the need for specialised PPE• Colour coded pink for easy identification

SPILL KITS

NEW

NEW

NEW

Page 44: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au44

Part No. Image Description

TIGER TAILS® (TORAPOLI PIPE)

DB35A

• Made of a high grade HDPE split industry standard pipe, with unique high visibility striped patterns

• Tails feature an eyelet in bell housing, interlocking male to female• Suitable as electrical insulation PPE, mechanical protection and visual

warning on power lines and conductors• Industry Standard complies with and marked to AS4202 Class 1• Maximum use 650V• High visibility• High electrical insulation• Resistant to many chemicals• Mechanically interlocks

INSULATING LINE COVERS

LSC225Electrical Insulation Cover 1200 X 225mm

• A high quality, dual layer PVC insulation barrier• Used by network personnel and contractors as PPE to cover

and drape over live conductors and power lines in low voltage environments• Light weight, reliable and durable• UV stabilised• Complies with and marked to AS4202 Class 2• Maximum use 650V• Strong physical properties

LSC300 Electrical Insulation Cover 1200 X 300mm

LSC375Electrical Insulation Cover 1200 X 375mm

INSULATING COVERS, MATS AND TIGER TAILS®

1. Is part and component replacement easy?2. Is there pull testing on the cable and joints?3. Is there cable sway testing on the cable and joints?4. Is there fault current testing on the cable, clamps or joints?5. Is it IEC compliant, certified and tested?6. Can you easily inspect for corrosion in the cable?

WHY CHOOSE DEHN AND EXTREME SAFETY?• Much longer lasting, and therefore lower lifetime cost • Easy part inspection and replacement• Full safety confidence with IEC certifications

PORTABLE EARTHING DEVICES - HV EARTHING SET FOR OH LINES OR SWITCHBOARDPart No. Image The sets consist of:

D-776470-SETSingle Pole Earth Set 70mm2 x 5m, rated to 19.5kA for 0.5sec; Universal clamps with bayonet attachment

D-776495-SETSingle Pole Earth Set 95mm2 x 5m, rated to 26.5kA for 0.5sec; Universal clamps with bayonet attachment

D-776412-SETSingle Pole Earth Set 120mm2 x 5m, rated to 33.5kA for 0.5sec; Universal clamps with bayonet attachment

D-776415-SETSingle Pole Earth Set 150mm2 x 5m, rated to 42kA for 0.5sec; Universal clamps with bayonet attachment

7. Can clamps work themselves loose?8. Does the cable have enough protection at joins to avoid cable fraying?9. Do you often have failures and need to replace units?10. Are replacement units readily available, or do you need to tie up cash and hold your own stock?

10 THINGS TO RECONSIDER WITH YOUR PORTABLE EARTHING DEVICE

Page 45: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au 45

ACCESSORIES - ATTACHMENT POINTS AND TOOLS FOR PORTABLE EARTHING DEVICESPart No. Image The sets consist of:

D-755225 D-774251 Straight ball joint with threaded shaft and nut

D-755200 Straight ball joint with female thread (for bolt)

D-754200 Fixed ball point 20mm/M12 (F)

D-754235 Fixed ball point 20mm, 12x35mm

D-756300 Angled ball joint with hole

D-761011 1m insulated rod for fitting portable earthing devices

D-761016 Insulated attachment pole 1.5m

D-769500 Telescopic insulated attachment pole 5.5m

D-772321 Clamp for ball and pin D-25mm

D-772331 Clamp for ball and pin D-20mm

D-773330 Clamp universal up to D-30mm

D-773331 Uni Clamp T-Pin (shaft long)

D-784085 Clamp for OH cable D10-85mm

D-770604 Switch board earth cable 70/35mm²

D-795604 Switch board earth cable 95/35mm²

D-712604 Portable switch board earth cable 120/50mm²

D-770604-S Overhead earth cable 70/35mm²

D-795604-S Overhead earth cable 95/35mm²

D-712604-S Overhead earth cable 120/50mm²

D-745502 Earthing clamp bare

D-774251 Clamp universal with handle

Ball Clamp

D-755225D-756300

D-755200

D-774251

D-761016

Universal Clamp OH Clamp

PORTABLE EARTHING DEVICES - HV EARTHING SET FOR OH LINES OR SWITCHBOARD

Part No. Image The sets consist of:

D-770604-SET D-770604 1 SB Earth 70/35 mm2 Cable D-773330 4 Clamp Universal up to D30mm

D-770604-S-SETD-770604-S 1 OH Earth 70/35 mm2 Cable D-773331 1 Clamp Uni T-pin Shaft Long D-784085 3 Clamp for OH Cable D10-85mm

D-795604-SET D-795604 1 SB Earth 95/35 mm2 Cable D-773330 4 Clamp Universal up to D30mm

D-795604-S-SETD-795604-S 1 OH Earth 95/35 mm2 Cable D-773331 1 Clamp Uni T-pin Shaft Long D-784085 3 Clamp for OH Cable D10-85mm

D-712604-SET D-712604 1 SB Earth 120/50 mm2 Cable D-773330 4 Clamp Universal up to D30mm

D-712604-S-SETD-712604-S 1 OH Earth 120/50 mm2 Cable D-773331 1 Clamp Uni T-pin Shaft Long D-784085 3 Clamp for OH Cable D10-85mm

Part No. Image The sets consist of:

D-758021 HV Discharge Device 465mm

D-745415-S Hot Stick 465mm EG ZK SN7138

D-758003 HV Discharge Device 2m

DISCHARGE DEVICE FOR VOLTAGE DISCHARGE AFTER HV TESTING

Page 46: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au46

Company:

Contact Name:

Phone:

Fax:

Email:

Mobile:

CUSTOM TEMPORARY EARTH SETS - ORDER FORM

FAX THIS FORM BACK TO CUSTOMER CARE

(Refer to number listed on the back of this brochure)

DESIGNING YOUR SET

STEP 1: CHOOSE YOUR CABLE SIZECable Cross Section / Max Short Circuit Current (@ 0.5sec)

16mm2 / 4,500A 25mm2 / 7,000A 35mm2 / 10,000A 50mm2 / 14,000A 70mm2 / 19,500A 95mm2 / 26,500A 120mm2 / 33,500A 150mm2 / 42,000A

Ball Universal OH Line

STEP 3: CHOOSE YOUR CABLE LENGTHS• Standard Switchboard earths are 600mm (A/B/C) and 1800mm (Earth)• Standard Overhead earths are 2000mm (A/B/C) and 7000mm (Earth)

NB: Cable lengths can be tailored to suit your needs.

STEP 2: CHOOSE YOUR CLAMP TYPE

CABLE LENGTH

CLAMP TYPE

CABLE SIZE

CABLE LENGTH

CLAMP TYPE

CABLE SIZE

CABLE LENGTH

CLAMP TYPE

CABLE SIZE

CABLE LENGTH

CLAMP TYPE

CABLE SIZE

ACCESSORIES NEEDED:

STIC

KS

QTY PART No

D-761011

D-761016

D-769500

BALL

+ P

IN

D-754235

D-754200

D-755200

D-755275

PORTABLE EARTHING DEVICES - HV EARTHING SET FOR OH LINES OR SWITCHBOARD

Page 47: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au 47

NOTES:

Page 48: Electrical Safety Equipment€¦ · Rubber Gloves Sizing Guide ... AS/NZS 2978 Electrical Mats Australian Standard for rubber matting IEC60903 Electrical Gloves European Standard

www.extremesafety.com.au48

For more information, please visit our website.

LPSPowerJointA4-1348

EXTREME SAFETY PROUDLY DISTRIBUTED BY:

In support of our policy of continuous product improvement we reserve the right to change materials and specifications without notice. Drawings, where used, are not to scale. All dimensions are in millimetres and sizes given are approximate. Where possible, technical MSDS data sheets are made available on the website. All products should be installed and used in accordance with manufacturer’s instructions provided. Warning: products may be the subject of registered designs and patents. Refer to website for terms and conditions on warranty.