ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau...

32
1 ELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S Bureau of Workers’ Comp PA Training for Health & Safety (PATHS) 1

Transcript of ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau...

Page 1: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

1

ELECTRICAL SAFETY

OSHA 29 CFR 1910

SUBPART S

Bureau of Workers’ Comp PA Training for Health & Safety

(PATHS)

1

Page 2: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

2

AN AVERAGE OF ONE WORKER IS ELECTROCUTED ON THE JOB EVERY DAY! There are four main types of electrical injuries: • Electrocution (death due to electrical shock)

• Electrical Shock

• Burns

• Falls

2 PPT-008-01

Page 3: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

3

▪ CURRENT = The movement of electrical charge.

▪ RESISTANCE = Opposition to current flow.

▪ VOLTAGE = A measure of electrical force.

▪ CONDUCTORS = Substances, such as metals, that have little resistance to electricity.

▪ INSULATORS = Substances, such as dry wood, rubber, glass and bakelite, that have high resistance to electricity.

▪ GROUNDING = A conductive connection to the earth which acts as a protective measure.

3 PPT-008-01

Page 4: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

4

Received when current passes through the body.

Severity of the shock depends on: • Path of current through the body • Amount of current flowing through

the body • Length of time the body is in the

circuit

LOW VOLTAGE DOES NOT MEAN LOW HAZARD!

4 PPT-008-01

Page 5: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

5

Currents greater than 75mA (1/1,000 of an ampere) can cause ventricular fibrillation (rapid, ineffective heartbeat). • Will cause death in a few

minutes unless a defibrillator is used.

• 75mA is not much current; a small power drill uses 30 times as much.

5 PPT-008-01

Page 6: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

6

When two wires have different potential voltages, current will flow if they are connected.

• In most household wiring, the black wires are at 110 volts relative to ground.

• The white wires are at zero volts because they are connected to ground.

Contact with an energized (live) black wire while touching the white grounded wire = ELECTRICAL

SHOCK!

6 PPT-008-01

Page 7: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

7

Contact with an energized wire/any energized electrical component + any grounded object = SHOCK!

You can even receive an electrical shock when you are not in contact with a ground.

CONTACT BOTH WIRES OF A 240 VOLT CABLE =

SHOCK, POSSIBLE ELECTROCUTION!

7 PPT-008-01

Page 8: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

8

Water is VERY conductive!

Reference: http://www.safteng.net

Page 9: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

9

• Are the most common shock-

related non-fatal injury

• Occur when you touch electrical wiring or equipment that is improperly used or maintained

• Typically occurs on the hands • Very serious injury that needs

immediate attention

9 PPT-008-01

Page 10: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

10

Electrical shock can also cause indirect or secondary injuries. Employees working in an elevated location who experience a shock can fall, resulting in serious injury or even death.

10 PPT-008-01

Page 11: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

11

A hazard exists when a conductor is too small to safely carry the current. Example: Using a portable tool with an extension cord that has a wire too small for the tool.

• Tool draws more current than cord can handle = overheating, possible fire without tripping the circuit breaker.

• Circuit breaker could be the right size for the circuit but not for the smaller wire extension cord.

Wire Gauge

WIRE

Wire gauge measures wires ranging in size from number 36 to 0 American

wire gauge (AWG)

11 PPT-008-01

Page 12: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

12

• Too many devices plugged into circuit = wires heat to very high temperature = possible fire

• Wire insulation melts = arcing may occur = fire in area where overload exists (even inside a wall)

12 PPT-008-01

Page 13: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

13

• Shut off electricity flow in the event of an overload or ground-fault in the circuit.

• Include fuses, circuit breakers and ground-fault circuit interrupters, or GFCIs.

• Fuses and circuit breakers are “over current” devices (too much current = fuses melt and circuit breakers “trip” open).

13 PPT-008-01

Page 14: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

14

Missing outlet cover!

Reference: http://www.safteng.net

Page 15: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

15

• Protects you from dangerous electrical shock.

• Detects a difference in current between the black and white circuit wires (could happen when electrical equipment is not working properly causing a current “leakage” known as ground fault).

• Ground fault detected = GFCI can shut off electricity flow in as little as 1/40 of a second protecting you from a dangerous shock.

15 PPT-008-01

Page 16: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

16

Electrical Hazards Ground-Fault Circuit-Interrupters (GFCIs)

Three types of GFCIs: • A GFCI receptacle used in place of

standard receptacle. • A portable GFCI plugs into a standard

receptacle. • A GFCI circuit breaker combines leakage

current detection with the function of a circuit breaker.

• Whenever working in a wet area, or

outdoors, employees should use one of these types of GFCI’s.

Page 17: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

17

• Metal parts of an electrical wiring system that we touch should be at 0 volts relative to ground (switch plates, ceiling light fixtures, conduit, etc.).

• Housings of motors, appliances or tools that are plugged in to improperly grounded circuits may become energized. If you come into contact with an improperly grounded

electrical device YOU WILL GET SHOCKED!

17 PPT-008-01

Page 18: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

18

GROUNDING PATH The path to ground from circuits, equipment and enclosures must be permanent and continuous.

18 PPT-008-01

Here the third/grounding prong is missing

Page 19: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

19

Electrical Hazard Control

• Pull the plug, not the cord. Pulling the cord could break a wire, causing a short circuit.

Page 20: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

20

HAND-HELD ELECTRICAL TOOLS:

Hand-held electrical tools pose a potential danger because they make continuous good contact with the hand.

To protect you from shock, burns and electrocution, tools must:

• Have a 3-wire cord with ground and be plugged into a grounded receptacle.

• Be double insulated.

• Be powered by a low-voltage isolation transformer.

20 PPT-008-01

Page 21: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

21

Must guard “live” parts of electrical equipment operating at > 50 volts against accidental contact by:

• Approved cabinets/enclosures.

• Location or permanent partitions (thereby only accessible to qualified persons).

• Elevation of 8 feet or more above the floor or working surface.

• Mark entrances to guarded locations with conspicuous warning signs.

21 PPT-008-01

Page 22: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

22

• Where electrical equipment is in locations that it can suffer physical damage it must be guarded.

• Shown here is physical damage to conduit.

22 PPT-008-01

Page 23: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

23

• Junction boxes, pull boxes and fittings must have approved covers.

• Unused openings in cabinets, boxes and fittings must be closed (no missing “knockouts”).

• Photo shows violations of these two requirements.

23 PPT-008-01

Page 24: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

24

• Are more vulnerable than fixed wiring.

• Should not be used if recognized wiring methods can be used instead.

• Flexible cords can be damaged by: o Aging

o Door or window edges

o Staples or fastenings

o Abrasion from adjacent materials

o Activities in the area

• Improper use of flexible cords can cause shocks, burns or fire. 24 PPT-008-01

Page 25: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

25

Pendant or Fixture Portable lamps, Stationary equipment Wiring tools or appliances to facilitate interchange

25 PPT-008-01

Page 26: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

26

26 PPT-008-01

Substitute for Fixed Wiring

Run through walls, ceilings, floors, doors, or windows

Concealed behind or attached to building

surfaces

Page 27: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

27

• Tripped circuit breakers or blown fuses

• Warm tools, wires, cords, connections or junction boxes

• GFCI that shuts off a circuit

• Worn or frayed insulation around wire or connection

27 PPT-008-01

Page 28: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

28

Train employees working with electrical equipment in safe working practices including:

• De-energizing electrical equipment before inspecting or making repairs. (Lock Out – Tag Out)

• Using electric tools in good repair.

• Using good judgment when working near energized lines.

• Using appropriate protective equipment or PPE.

28 PPT-008-01

Page 29: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

29

Hazards - Inadequate wiring

- Exposed electrical parts - Wires with bad insulation

- Ungrounded electrical tools/systems - Overloaded circuits

- Damaged power tools/equipment - Overhead power lines

All hazards are made worse in wet conditions!

29 PPT-008-01

Page 30: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

30

Protective Measures

▪ Proper grounding

▪ Using GFCIs

▪ Using fuses and circuit breakers

▪ Proper use of flexible cords

▪ Training

30 PPT-008-01

Page 31: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

31

The bottom line with electricity:

RESPECT

HAZARD RECOGNITION

SAFETY

31 PPT-008-01

Page 32: ELECTRICAL SAFETY - Augusta · PDF fileELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S . Bureau of Workers’ Comp ... transformer. PPT-008-01 20 . Georgia Department of Administrative

Georgia Department of Administrative Services

32

Risk Management Services

Contact Information Hiram S. Lagroon, BS

Chief Loss Control & Safety Officer (404) 463-6309

[email protected]

Charles G. Lawrence, III, CSP, REM, ARM-P Chief Loss Control & Safety Officer

(404) 657-4457 [email protected]

Questions?