Electrical plant. Traditional wall (Red hollow brick) Plasterboard wall Rapid installation flush...
-
Upload
laura-barton -
Category
Documents
-
view
215 -
download
1
Transcript of Electrical plant. Traditional wall (Red hollow brick) Plasterboard wall Rapid installation flush...
Electrical plant
Traditional wall (Red hollow brick)
Plasterboard wall
Rapid installation flush mounting solution FINAL EFFECT
Traditional wall (Red hollow brick)
Plasterboard wall
TOTAL flush mounting solution with precision installation
FINAL EFFECT
Flush mounting solutions
SFM3
Solution for Traditional wall (Red hollow brick)
1 – Make a hole in the wall and fix the box using the builder’s level provided
2 - Apply coarse mortar(DO NOT apply the frame during this operation)
3 - Finishing(DO NOT apply the frame during this operation)
4 – Fix the frame to the box, paint the wall and the frame only after installation
5 - Apply the finish plate
Rapid installation flush mounting solution
SFM3CG
Solution for plasterboard wall
1 – Apply the template to the wall and use the builder’s level to mark the outline
2 – Cut hole
3 – After inserting the box apply a skim coat to the wall (DO NOT apply the frame during this operation)
4 – Fix the frame to the box, paint the wall and the frame only after installation
5 - Apply the finish plate
Rapid installation flush mounting solution
Using the rapid installation solution you will have the plate flush with the wall surrounded by the narrow paintable panel covering any imperfections between the edge of the box and the cement
Rapid installation flush mounting solution
TOTAL flush mounting solution with precision installation
SFM3/HP
Solution for traditional wall (Red hollow brick)
1 – Make a hole and fix the box using the builder’s level provided
2 – Apply the coarse mortar
3 – Apply the finish coat
5 – Apply the finish plate
4 – Paint the wall
Solution for plasterboard wall
1 – Apply the template to the wall use the builder’s level to mark the outline
2 – Cut hole
3 – After inserting the box apply the skim coat to the wall
TOTAL flush mounting solution with precision installation
SFM3CG/HP
5 – Apply the finish plate
4 – Paint the wall
Using the TOTAL flush mounting solution with precision installation you will have the plate flush with the wall completely embedded without a cover frame
TOTAL flush mounting solution with precision installation