ElectricalElectricalHazardsHazards
![Page 2: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/2.jpg)
Temporary Wiring and Lighting Systems
![Page 3: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/3.jpg)
Electrical Harm
Estimated Effects of AC Currents (U.S. Standard 60 Hz)
1 milliamp (mA)
Barely perceptible
16 mA Maximum current an average man can grasp and “let go”
20 – 30 mA Paralysis of respiratory muscles
100 mA Ventricular fibrillation threshold
2 Amps Cardiac standstill and internal organ damage
15/20/30 Amps
Common U.S. household breakers
PATH: Harm is related to the path by which current passes through the body.
![Page 4: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/4.jpg)
Ground Fault Circuit Interrupters(GFCI)
• Monitors current flow between the hot and neutral wires
• Trip between 4-6 mA in 1/40th of a second
![Page 5: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/5.jpg)
How GFCIs Work
![Page 6: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/6.jpg)
Assured Equipment Grounding Program
• Inspection is your primary protection
• Best practice recommends documented testing every 3 months
• Color coding most common:
Winter Spring Summer Fall
![Page 7: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/7.jpg)
Reverse Polarity Diagram
Hot
Neutral
Switch
Tool could be hot with the switch offHot wire and neutral wire are reversedEven though a switch is off, the circuit could be hot
![Page 8: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/8.jpg)
Electrical Extension Cords
• The primary insulation is cut• If the insulation was also cut on
the conductors, exposing bare wires, they could come in contact with someone
• Damage is often caused by repeated stretching or being run over
![Page 9: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/9.jpg)
Electrical
• Wiring like this must be protected in closed boxes
• There is the potential of electric shock from loose wire nuts or exposed conductors
![Page 10: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/10.jpg)
Electrical Panel Boxes
• Live electrical panels must be completely covered with a hard cover (original intended equipment)
• Employees could be exposed to live wires around the perimeter of this box
• No Cardboard!
![Page 11: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/11.jpg)
![Page 12: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/12.jpg)
Arc Flash Prevention
![Page 13: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/13.jpg)
An electric arc:
• Typically lasts less than a second• Has extremely high radiant (heat) energy• Is explosive in nature (exerts great force)• Can ignite or melt conventional work
clothing
![Page 14: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/14.jpg)
![Page 15: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/15.jpg)
Pressure Waves > 2000 lb/psf
Copper Vapor:Solid to VaporExpands by67,000 times
Molten Metal > 1800 ° F
Intense Light
Hot Air >500 ° F
35,000 °F
Shrapnel > 740 mph
Sound Waves >140db
Electrical Arc
![Page 16: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/16.jpg)
NFPA 70E Requirements
• Arc flash boundaries must be known• Safe approach distances established and
maintained• Marking equipment relative to hazards• Electrically safe (voltage rated) tools• PPE (ATPV)• Training
![Page 17: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/17.jpg)
The Best Way to Work on Energized Electrical Equipment?
• Shut it down and lock it out • Establish an electrically safe
working condition
DON’T!
![Page 18: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/18.jpg)
Overhead Powerlines
![Page 19: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/19.jpg)
![Page 20: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/20.jpg)
![Page 21: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/21.jpg)
The Sad Reality
![Page 22: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/22.jpg)
Power Line Facts
• Overhead lines are typically not insulated. Any covering is generally a weather protection, not insulation.
• Over 90 percent of the contacts occur on overhead distribution lines
• Operators are normally safe if they stay on the equipment
• Ground personnel are over 8 times more likely to be killed
![Page 23: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/23.jpg)
Electrical Damage to the Body• If you touch a power line,
electricity will attempt to travel through your body
• When electricity travels through the body, it heats up and burns body tissue internally
• Electricity leaves the body violently, causing burns or even blowing an exit hole
![Page 24: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/24.jpg)
Maintain Safe Working Clearance
• All equipment – ladders, scaffolds, cranes, trucks, forklifts, etc. – MUST maintain a minimum 10 foot clearance from 50 kV or less
• Add .4 inches for every kV over 50 kV
![Page 25: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/25.jpg)
MINIMUM 10' Distance
![Page 26: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/26.jpg)
Ensure Adequate Clearance
• Install flag warnings at proper distances
• If it is difficult for an operator to see the power lines, designate a spotter
• If you cannot maintain adequate clearances, you must have the power company insulate, move or de-energize the line
![Page 27: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/27.jpg)
• Insulated Sleeves Must be Installed by the Utility Company
• Allow Sufficient Time• Must Still Maintain
Minimum Line Clearance Distance
Insulated Sleeve
Insulated Blanket
Barrier Protection
![Page 28: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/28.jpg)
The Ground May Be Hot!
• Electricity dissipates with the resistance of the ground
• As potential drops, fields develop around the electrified machine
• If you step across a line of unequal potential, you could be electrocuted
![Page 29: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/29.jpg)
If Contact Occurs
• Stay on the machine if possible
• Warn all others to stay away
• Notify power company immediately
• Attempt to move away but assure line is not “connected”
![Page 30: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/30.jpg)
Bail Out Procedures
• If you must get out, jump with your feet together
• Do not touch the machine
• Hop or shuffle out of the area
![Page 31: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/31.jpg)
Lightning?
![Page 32: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/32.jpg)
Lightning Safety• If you hear thunder, suspend
all outdoor activities!• If you see Lightning, seek a
shelter immediately!• Cranes - lower boom and
stop operations and move to shelter
• Those people who are working at heights - climb down and take shelter in a protected building / safe area
![Page 33: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/33.jpg)
Incident FreeIncident Free
• Planning – Installation of temporary power– For working around electrical panels– Work around overhead power lines
• Training– Workers about circuit contact– For Arc-flash prevention and protection– For safe work around overhead power lines
• Inspection– Electrical tools and equipment– Electrical panels for live circuits– Temporary wiring & lighting
![Page 34: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/34.jpg)
Incident FreeIncident Free
• Oversight– Electrical installations– Site issues around power lines
• Lessons learned– Accidents with circuit contacts– Arc-flash incidents– Power line contacts
• Re-evaluate – Temporary electric specifications– Electrical work practice
![Page 35: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/35.jpg)
Competent Person
• A competent person is someone who:– Is capable of identifying existing and
predictable hazards in the surroundings or working conditions that are unsanitary, hazardous, or dangerous to employees, and
– Has the authorization to take prompt corrective measures to eliminate them
![Page 36: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/36.jpg)
Incident FreeIncident Free
• Planning
• Training
• Inspection
• Oversight
• Lessons learned
• Re-evaluate
![Page 37: Electrical Hazards Temporary Wiring and Lighting Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061503/5697bf941a28abf838c9031c/html5/thumbnails/37.jpg)
SummarySummary
• The focus four hazards are responsible for the majority of physical, financial, and emotional losses in construction — and they exist on nearly every jobsite.
• It takes a well-trained crew (the entire crew!) and lots of pre-planning to recognize and respond to those hazards. Safety is everyone's responsibility — ALL of the time.