Electrical and Photovoltaic Installations Tester: MI 3108 MI 3109...A set of testers and accessories...

5
Electrical Installation Safety 1. 6 Accessories: page 1.60 PHOTOVOLTAIC AND ELECTRICAL INSTALLATIONS TESTER Electrical and Photovoltaic Installations Tester: MI 3108 EurotestPV

Transcript of Electrical and Photovoltaic Installations Tester: MI 3108 MI 3109...A set of testers and accessories...

Page 1: Electrical and Photovoltaic Installations Tester: MI 3108 MI 3109...A set of testers and accessories for testing, evaluation Measurements according to EN 62446: • Insulation •

Electrical Installation Safety Electrical Installation Safety

1. 6 1. 7Accessories: page 1.60 Accessories: page 1.60

PHOTOVOLTAIC AND ELECTRICAL INSTALLATIONS TESTER PHOTOVOLTAIC AND ELECTRICAL INSTALLATIONS TESTER

Electrical and Photovoltaic Installations Tester:MI 3108 EurotestPV

Part No.MI 3108 MI 3109

EurotestPV EurotestPV Lite

Features Description

ELECTRICAL INSTALLATION SAFETY

Insulation resistance up to 1000 V

Continuity 200 mA

Line / Loop Impedance –

RCD A, AC, B –

Earth resistance –

Rotary field –

PV GENERATOR MEASUREMENTS

Isc, Uoc 1000 V / 15 A 1000 V / 15 A

Automatic test sequence –

I-V curve

Umpp, Impp, Pmax

extrapolation to STC *

Rs (calculated in PC SW)

ENVIRONMENT MEASUREMENTS

Irradiance *

Module temperature *

PV SYSTEM POWER MEASURENMENTS

DC side measurements U, I, P

AC side measurements (single phase) U, I, P

PV and inverter energy conversion efficiency

EXTENDED POWER FUNCTIONALITY

P, Q, S, THDU, PF/cos ϕ –

AC/DC current –

Scope function –

Energy –

Harmonics (up to 11th) –

GENERAL DATA

Memory sizeI-V curve: ca. 500 meas. Other: ca 1800 meas.

Supply 6 x AA

Built-in battery charger

Display 128 x 64 BW LCD

Overvoltage categoryCAT II / 1000 V DC

CAT III / 600 VCAT IV / 300 V

PC connectivity

PC Software EuroLink PRO EuroLink PRO

Weight (kg) 1.3 1.3

Dimensions (mm) 230 x 103 x 115 230 x 103 x 115

* Environment data can be entered manually or measured with optional accessory

Selection Guide for Photovoltaic and Electrical installations Testers

Page 2: Electrical and Photovoltaic Installations Tester: MI 3108 MI 3109...A set of testers and accessories for testing, evaluation Measurements according to EN 62446: • Insulation •

1 2 3

DC SWITCH

1 0

AC SWITCH

1 0

L1

L2

L3

N

P

IN I3 C B A I1

L1 L3C

N A

I2

L2 B

A 1436

BluetoothTMoror

A 1436

Bluetooth

TM

TM

TM

RS232

PHOTOVOLTAIC AND ELECTRICAL INSTALLATION TESTERSMI 3108 EurotestPV and MI 3109 EurotestPV Lite

PHOTOVOLTAIC AND ELECTRICAL INSTALLATION TESTERSMI 3108 EurotestPV and MI 3109 EurotestPV Lite

PHOTOVOLTAIC AND ELECTRICAL INSTALLATION TESTERSMI 3108 EurotestPV and MI 3109 EurotestPV Lite

Electrical installation safety measurements:• Voltage and frequency,• Continuity tests,• Insulation resistance tests,• RCD testing,• Fault loop / RCD trip-lock impedance

measurements,• Line impedance / Voltage drop,• Phase sequence,• Earthing resistance tests,• Current measurements,• Power, harmonics and energy meas-

urements.

For complete electrical installation testing according to EN 61557 standards.

Recording of environment parameters:• Irradiance• Panel temperature• Ambient temperature.

Without accurate, real time values of environment parameters calculations of SCT values are not possible.

DC and AC Power measurements on PV generator and inverter:• Voltages, currents and power• Efficiency calculation• Scope function

PC SW EuroLink PRO Plus• Download, analysis and reporting

Module characteristics:• I-U Curve• Power Curve• Calculation of STC values• Determination of Pmpp

For first inspection, for periodic tests, for performance evaluation and troubleshooting of PV generators.

A set of testers and accessories for testing, evaluation and troubleshooting of photovoltaic installations.

Measurements according to EN 62446:• Insulation• Continuity• Uoc• Isc

Measurements according to EN 62446:• Insulation resistance tests,• Continuity tests,• Uoc and Isc measurements.

This are the minimum requirements for system documentation, commissioning tests, and inspection of PV installations.

New Commanders:With enhanced functionality to make testing even more effective.

For power and efficiency measurements on single or 3-phase inverters: 3-phase measurements are possible in combination with Metrel’s PQA instruments MI 2892, MI 2792, MI 2592, MI 2492 and MI 2392.

Safe PV array measurements with PV Safety Probe:• Up to 1000 V & 15 A

Safe disconnection in any situation is ensured

Page 3: Electrical and Photovoltaic Installations Tester: MI 3108 MI 3109...A set of testers and accessories for testing, evaluation Measurements according to EN 62446: • Insulation •

1 2 3

DC SWITCH

1 0

AC SWITCH

1 0

L1

L2

L3

N

P

IN I3 C B A I1

L1 L3C

N A

I2

L2 B

A 1436

BluetoothTMoror

A 1436

Bluetooth

TM

TM

TM

RS232

PHOTOVOLTAIC AND ELECTRICAL INSTALLATION TESTERSMI 3108 EurotestPV and MI 3109 EurotestPV Lite

PHOTOVOLTAIC AND ELECTRICAL INSTALLATION TESTERSMI 3108 EurotestPV and MI 3109 EurotestPV Lite

PHOTOVOLTAIC AND ELECTRICAL INSTALLATION TESTERSMI 3108 EurotestPV and MI 3109 EurotestPV Lite

Electrical installation safety measurements:• Voltage and frequency,• Continuity tests,• Insulation resistance tests,• RCD testing,• Fault loop / RCD trip-lock impedance

measurements,• Line impedance / Voltage drop,• Phase sequence,• Earthing resistance tests,• Current measurements,• Power, harmonics and energy meas-

urements.

For complete electrical installation testing according to EN 61557 standards.

Recording of environment parameters:• Irradiance• Panel temperature• Ambient temperature.

Without accurate, real time values of environment parameters calculations of SCT values are not possible.

DC and AC Power measurements on PV generator and inverter:• Voltages, currents and power• Efficiency calculation• Scope function

PC SW EuroLink PRO Plus• Download, analysis and reporting

Module characteristics:• I-U Curve• Power Curve• Calculation of STC values• Determination of Pmpp

For first inspection, for periodic tests, for performance evaluation and troubleshooting of PV generators.

A set of testers and accessories for testing, evaluation and troubleshooting of photovoltaic installations.

Measurements according to EN 62446:• Insulation• Continuity• Uoc• Isc

Measurements according to EN 62446:• Insulation resistance tests,• Continuity tests,• Uoc and Isc measurements.

This are the minimum requirements for system documentation, commissioning tests, and inspection of PV installations.

New Commanders:With enhanced functionality to make testing even more effective.

For power and efficiency measurements on single or 3-phase inverters: 3-phase measurements are possible in combination with Metrel’s PQA instruments MI 2892, MI 2792, MI 2592, MI 2492 and MI 2392.

Safe PV array measurements with PV Safety Probe:• Up to 1000 V & 15 A

Safe disconnection in any situation is ensured

Page 4: Electrical and Photovoltaic Installations Tester: MI 3108 MI 3109...A set of testers and accessories for testing, evaluation Measurements according to EN 62446: • Insulation •

1 2 3

DC SWITCH

1 0

AC SWITCH

1 0

L1

L2

L3

N

P

IN I3 C B A I1

L1 L3C

N A

I2

L2 B

A 1436

BluetoothTMoror

A 1436

Bluetooth

TM

TM

TM

RS232

PHOTOVOLTAIC AND ELECTRICAL INSTALLATION TESTERSMI 3108 EurotestPV and MI 3109 EurotestPV Lite

PHOTOVOLTAIC AND ELECTRICAL INSTALLATION TESTERSMI 3108 EurotestPV and MI 3109 EurotestPV Lite

PHOTOVOLTAIC AND ELECTRICAL INSTALLATION TESTERSMI 3108 EurotestPV and MI 3109 EurotestPV Lite

Electrical installation safety measurements:• Voltage and frequency,• Continuity tests,• Insulation resistance tests,• RCD testing,• Fault loop / RCD trip-lock impedance

measurements,• Line impedance / Voltage drop,• Phase sequence,• Earthing resistance tests,• Current measurements,• Power, harmonics and energy meas-

urements.

For complete electrical installation testing according to EN 61557 standards.

Recording of environment parameters:• Irradiance• Panel temperature• Ambient temperature.

Without accurate, real time values of environment parameters calculations of SCT values are not possible.

DC and AC Power measurements on PV generator and inverter:• Voltages, currents and power• Efficiency calculation• Scope function

PC SW EuroLink PRO Plus• Download, analysis and reporting

Module characteristics:• I-U Curve• Power Curve• Calculation of STC values• Determination of Pmpp

For first inspection, for periodic tests, for performance evaluation and troubleshooting of PV generators.

A set of testers and accessories for testing, evaluation and troubleshooting of photovoltaic installations.

Measurements according to EN 62446:• Insulation• Continuity• Uoc• Isc

Measurements according to EN 62446:• Insulation resistance tests,• Continuity tests,• Uoc and Isc measurements.

This are the minimum requirements for system documentation, commissioning tests, and inspection of PV installations.

New Commanders:With enhanced functionality to make testing even more effective.

For power and efficiency measurements on single or 3-phase inverters: 3-phase measurements are possible in combination with Metrel’s PQA instruments MI 2892, MI 2792, MI 2592, MI 2492 and MI 2392.

Safe PV array measurements with PV Safety Probe:• Up to 1000 V & 15 A

Safe disconnection in any situation is ensured

Page 5: Electrical and Photovoltaic Installations Tester: MI 3108 MI 3109...A set of testers and accessories for testing, evaluation Measurements according to EN 62446: • Insulation •

SOLUTIONS FOR TESTING _Junij_2014_Ang

METREL d.d.Measuring and Regulation Equipment Manufacturer Ljubljanska 77, SI-1354 HorjulTel: +386 (0)1 75 58 200; Fax: +386 (0)1 75 49 226E-mail: metrel∞metrel.si; http://www.metrel.si

METREL GmbHMetrel Mess- und Prüftechnik GmbHOrchideenstraße 24, 90542 EckentalTel.: +49 9126 28996-0; Fax: +49 9126 28996-20E-mail: metrel∞metrel.de; http://www.metrel.de

Metrel UK Ltd. Test and Measuring Equipment Unit 1, Hopton House, Ripley Drive,Normanton, West Yorkshire, WF6 1QT Tel.: +44 (0) 1924 245 000 E-mail: info∞metrel.co.uk; http://www.metrel.co.uk

Note! Photographs in this catalogue may slightly differ from the instruments at the time of delivery. Subject to technical change without notice.

4

APPLICATIONS AND SOLUTIONS FOR TESTING AND ANALYSIS OF:

� Photovoltaic modules, strings and complete installations � Photovoltaic generator standards compliance � Troubleshooting of Photovoltaic systems � System documentation, commissioning, tests, and inspection of PV installations �Open Circuit Voltage and Short Circuit Current � I - U curve of PV modules and strings � Remote recording of solar irradiation and PV module temperature � Calculation of STC values � Power and efficiency calculations �Automatic test procedure according to EN 62446

PHO

TOV

OLT

AIC

AN

D E

LECT

RICA

L IN

STA

LLA

TIO

N T

ESTE

RSC

om

bin

ed P

ho

tovo

ltai

c &

Ele

ctri

cal M

ult

ifu

nct

ion

Tes

tin

g S

olu

tio

n

PHOTOVOLTAIC AND ELECTRICAL INSTALLATION TESTERSMI 3108 EurotestPV and MI 3109 EurotestPV LiteMI 3108 EurotestPV is a combined photovoltaic tester and electrical installations safety tester. It enables complete testing of electrical installations according to EN 61557 standards and in addition performs all necessary tests required on photovoltaic (PV) installations. This includes all of the tests as required by EN 62446, but also includes I - U characteristic, Calculation of STC values and power measurements on Inverter’s DC and AC sides. The unit is designed for the demanding working conditions (up to 1000 V, with 15 A DC). To greatly improve user safety the MI 3108 EurotestPV comes with the PV Safety Probe which ensures safe disconnection every time.

MI 3109 EurotestPV Lite is optimized for PV tests only. The Auto function is intended to perform a complete set of test needed for verification of PV installations according to EN 62446. With optional accessories the same PV test functionality as with MI 3108 EurotestPV is available.

MEASURING FUNCTIONS Photovoltaic installations:Measurements on DC side of PV instal-lation:• Voltage, current, power;• Uoc (Open Circuit Voltage) and Isc

(Short Circuit Current)• I - U curve of PV modules and strings;• Irradiance;• Module temperature.Measurements on AC side of PV installation (power quality):• Voltage, current, frequency, power, PF,

energy, harmonics;• Efficiency of PV module, inverter, PV

system calculation.

Electrical installations (MI 3108 only):• Insulation resistance*;• Continuity of PE conductors*;• Line impedance;• Loop impedance (sub-functions with

high current and without RCD tripping);• RCD testing (type AC, A and B);• Earth resistance;• AC current (load and leakage);• TRMS voltage, frequency, phase sequence;• Power, energy, harmonics.* Valid also for MI 3109

KEY FEATURES Photovoltaic installations:• Automatic test procedure according to

EN 62446 (MI 3109 only);• Calculation of STC values;• Efficiency calculations;• Graphical representation of module’s

I - U curve;• 2 voltage & 2 current channels for

simultaneous AC & DC parameters measurements;

• Optional 3-phase measurements in com-bination with Metrel’s PQA instruments.

• Optional PV Remote Unit for simultaneous measurements of solar ir-radiation and temperature of PV module.

Electrical installations (MI 3108 only):• Automated RCD testing procedure;• Support for B type RCD;• Earth resistance measurement;• Built-in fuse tables for automatic evalua-

tion of the line / loop impedance results;• Online monitoring of all 3 voltages;• Scope function;• Loop impedance test without tripping

the RCD;• 1-phase power and energy measurements

(including harmonics up to 11th).

MI 3109 MI 3108Electrical installation safetyInsulation resistance up to 1000 V −

Continuity 200 mA − Line / Loop Impedance − RCD A, AC,B − Earth resistance − Rotary field − PV installation safety (Panel)Insulation resistance up to 1000 V

Continuity 200 mA Uoc, Isc (1000 V/15 A) Extrapolation to STC I-V curve Vmpp, Impp, Pmax Solar measurements:Irradiance ○ / Module temperature ○ / Automatic test sequence

PV installation safety (Power) DC side measurements: U, I Power AC side measurements (single phase):U, I f Power PV array and inverter energy conversion efficiency

PF − Energy − Harmonics − Scope − GeneralMemory size I-V curve, Power (Scope) ~ 500 measurementsOther measurements ~ 1800 measurementsPC connectivity

Acc

esso

ries

MI 3

109

MI 3

108

STPS

STPS

A 1

401

Tip

com

man

der

--

○●

A 1

384

PV

saf

ety

prob

e○

●●

●A

142

7 P

V R

efer

ence

Cel

l ○

●●

●A

140

0 Te

mpe

ratu

re p

robe

○●

●●

A 1

391

AC

/DC

cur

rent

cl

amp

adap

ter

●●

●●

A 1

378

Rem

oteP

V○

●○

●M

C3,

MC

4 ad

apto

rs●

●●

- A

vaila

ble,

● –

Sta

ndar

d ac

cess

ory,

○ –

Opt

iona

l acc

esso

ry