ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC...

71
09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF www.nem-hydraulics.com

Transcript of ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC...

Page 1: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

62

DIRECTIONAL VALVES

ELECTRIC CARTRIDGES ON/OFF

ELECTRIC CARTRIDGES

VALVES ON/OFF

www.nem-hydraulics.com

Page 2: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

63

The hydraulic circuits of mobile machinery, are often equipped with automatic devices or remote controls that require the use of electro hydraulic systems to generate hydraulic power from an electric signal.

The components capable of doing this are called electric valves or solenoid valves. These valves are hydraulic components that by using a specific mechanical devices can obtain linear movements using the force generated by a magnetic field of a coil fed with current.

NEM production of solenoid cartridge valves is based on SAE cavity and can cover most of the available circuit: 2 and 3 way 2 positions direct acting lock valves, 2 way 2 position pilot operated lock valves and spool valves 2, 3 and 4 way.

The main characteristics of NEM solenoid cartridge valves is the design and construction of the “Tube”: without any kind of welding, the working principle is based on the tube magnetic saturation, it makes the valve stronger and reliable at high pressures, with an excellent electromagnetic performance. Each NEM solenoid cartridge valve has a dedicated coil (to be ordered as separate item).The coil has to be selected through the specifications available on the technical sheet, with respect to required voltage and type of connector.

INTRODUCTION

DIRECTIONAL VALVES

ELECTRIC CARTRIDGES ON/OFF

www.nem-hydraulics.com5.00.000

COIL

TUBE

CORE

Page 3: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

64

www.nem-hydraulics.com5.00.001

2 WAYS DIRECTIONAL CONTROL VALVES ON/OFF

1 2

21

1 2

1 2

1 2

DIRECTIONAL VALVES

ELECTRIC CARTRIDGES ON/OFF

Flowl/min

Pmax bar SIZE CAVITY PAGE

CT-502 NC 20 250 SAE-08 C220000 5.01.001

CT-503 NC 30 350 SAE-10 C230000 5.01.002

CT-512 NA 40 350 SAE-08 C220000 5.01.003

CT-513 NA 60 350 SAE-10 C230000 5.01.004

CT-514 NA 150 350 SAE-12 C240000 5.01.005

CT-512 NC 40 350 SAE-08 C220000 5.01.006

CT-513 NC 60 350 SAE-10 C230000 5.01.007

CT-514 NC 150 350 SAE-12 C240000 5.01.008

CT-532 NA 2 350 SAE-08 C220000 5.01.009

CT-532 NC 2 350 SAE-08 C220000 5.01.010

Page 4: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

65

3 WAYS DIRECTIONAL CONTROL VALVES ON/OFF

3

2

1

1 2

1 2

1 2

1 2

www.nem-hydraulics.com5.00.002

DIRECTIONAL VALVES

ELECTRIC CARTRIDGES ON/OFF

Flowl/min

Pmax bar SIZE CAVITY PAGE

CT-562 NA 30 300 SAE-08 C220000 5.01.019/A CT-562 NA 40 350 SAE-08 C220000 5.01.019/B

CT-563 NA 60 350 SAE-10 C230000 5.01.020

CT-564 NA 150 350 SAE-12 C240000 5.01.021

CT-562 NC 30 300 SAE-08 C220000 5.01.022/A

CT-562 NC 40 350 SAE-08 C220000 5.01.022/B

CT-563 NC 60 350 SAE-10 C230000 5.01.023

CT-564 NC 150 350 SAE-12 C240000 5.01.024

CT-552 NA 30 300 SAE-08 C220000 5.01.011/A

CT-552 NA 40 350 SAE-08 C220000 5.01.011/B

CT-553 NA 60 350 SAE-10 C230000 5.01.012

CT-554 NA 150 350 SAE-12 C240000 5.01.013

CT-552 NC 30 300 SAE-08 C220000 5.01.015/A CT-552 NC 40 350 SAE-08 C220000 5.01.015/B

CT-553 NC 60 350 SAE-10 C230000 5.01.016

CT-554 NC 150 350 SAE-12 C240000 5.01.017

CT-402.1 15 250 SAE-08 C320000 5.01.025

CT-565 NA 200 250 SAE-16 C250000 5.01.014

CT-565 NC 200 350 SAE-16 C250000 5.01.018

Page 5: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

66

Flowl/min

Pmax bar SIZE CAVITY PAGE

CT-403.2 20 250 SAE-10 C330000 5.01.030

CT-404.2 55 250 SAE-12 C340000 5.01.031

CT-423.2 30 350 SAE-10 C330000 5.01.032

4 WAYS DIRECTIONAL VALVES ON/OFF

CT-412.2 10 210 SAE-08 C420000 5.01.033

CT-413.2 25 250 SAE-10 C430000 5.01.034

CT-402.3 BP 5 50 SAE-08 C320000 5.01.026

CT-402.3 15 250 SAE-08 C320000 5.01.027

3

2

1

CT-402.2 13,5 250 SAE-08 C320000 5.01.029

CT-402.4 15 250 SAE-08 C320000 5.01.028

3

2

1

3

2

1

3

2

1

4

3

2

1

www.nem-hydraulics.com5.00.003

DIRECTIONAL VALVES

ELECTRIC CARTRIDGES ON/OFF

Page 6: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

67

CT-462.1 10 210 SAE-08 C420000 5.01.035

CT-463.1 25 250 SAE-10 C430000 5.01.036

CT-412.3 10 210 SAE-08 C420000 5.01.033

CT-413.3 25 250 SAE-10 C430000 5.01.034

CT-462.2 10 210 SAE-08 C420000 5.01.037

CT-463.2 25 250 SAE-10 C430000 5.01.038

CT-463.3 25 250 SAE-10 C430000 5.01.040

CT-462.3 10 210 SAE-8 C420000 5.01.039

CT-463.4 25 250 SAE-10 C430000 5.01.042

CT-462.4 10 250 SAE-8 C420000 5.01.041 24

13

3

4 2

1

3

4 2

1

3

4 2

1

1

24

3

www.nem-hydraulics.com5.00.004

DIRECTIONAL VALVES

ELECTRIC CARTRIDGES ON/OFF

Flowl/min

Pmax bar SIZE CAVITY PAGE

Page 7: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

68

Ordering code

2 WAYS 2 POSITIONS ELECTRIC VALVE DIRECT ACTING POPPET OPERATED NC

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 l/min• Max working pressure . . . . . . . . . . . . . . . . . . . .250 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . .0,25 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NBR • Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C220000 • Cartridge thightening torque . . . . . . . . . . . . . . . 30 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil) . . . . . . . . . . . . . . . . . . . . . . . 0,32 Kg• Coil CT-9400 to be ordered separately

0 4

No emergency

0 5 0 2 1 0 0 0 0

5

CT-502 NC

Push Button

Push andTwist

Cartridge SAE 8

Flow [l/min]0 5 10 15 20 25

Pres

sure

[ba

r]

300

250

200

150

100

50

0

0 5 10 15 20 25

35

30

25

20

15

10

5

0

1 2

Pres

sure

[ba

r]

Application limits from 1 in 2 and 2 in 1

Pressure drop with energized coil

www.nem-hydraulics.com5.01.001

Flow [l/min]

45,2

16,40

61,9

27,5

Ø 12,7

1

2

3/4-16 UNF2A

Hex.24

Page 8: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

69

Ordering code

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 l/min• Max working pressure . . . . . . . . . . . . . . . . . . . 350 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . .0,25 cc/min• Seals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NBR• Cavità . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C230000• Cartridge thightening torque. . . . . . . . . . . . . . . . 40 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). .. . . . . . . . . . . . . . . . . . . . . . .0,56 Kg• Coil CT-9800 to be ordered separately

Push pin

1 4

0 5 0 3 1 0 0 0 0

50

CT-503 NC

2 WAYS 2 POSITIONS ELECTRIC VALVE DIRECT ACTING POPPET OPERATED NC

Cartridge SAE 10

1

2

0 5 10 15 20 25 30 35

400

350

300

250

200

150

100

50

0

0 5 10 15 20 25 30 35 40

30

25

20

15

10

5

0

1 2

Pres

sure

[ba

r]Pr

essu

re [

bar]

1 = Limits from 2 to 1

12

2 = Limits from 1 to 2

www.nem-hydraulics.com5.01.002

Flow [l/min]

Flow [l/min]

No emergency Push Button

Push andTwist

Pressure drop with energized coil

Ø38

8132

,5

Ø 15,81

2

7/8-14 UNF-2A

Hex.27

Page 9: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

70

Ordering code

2 WAYS 2 POSITIONS ELECTRIC VALVE, PILOT POPPET OPERATED NO

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 l/min• Max working pressure . . . . . . . . . . . . . . . . . . . 350 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 0,25 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C220000• Cartridge thightening torque. . . . . . . . . . . . . . . . 30 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil) . . . . . . . . . . . . . . . . . . . . . . .0,32 Kg• Coil CT-9400 to be ordered separately

0 4

0 5 1 2 0 0 0 0 0

5

CT-512 NACartridge SAE 8

0 5 10 15 20 25 30 35 40 45

400

350

300

250

200

150

100

50

0

0 5 10 15 20 25 30 35 40 45 50

8

6

4

2

0

21

Pressure drop from 2 to 1 and from 1 to 2

www.nem-hydraulics.com5.01.003

No emergency Push Button

Push andTwist

Flow [l/min]

Pres

sure

[ba

r]Pr

essu

re [

bar]

Flow [l/min]

Application limits from 2 to 1 and 1 to 2

45,2

16,40

67,3

27,5

Ø 12,7

1

2

3/4-16 UNF2A

Hex.24

Page 10: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

71

Ordering code

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 l/min• Max working pressure . . . . . . . . . . . . . . . . . . .350 bar• Leakage. . . . . . . . . . . . . . . . . . . . . . . . . . .0,25 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C230000• Cartridge thightening torque . . . . . . . . . . . . . . . 40 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil) . . . . . . . . . . . . . . . . . . . . . . . 0,56 Kg• Coil CT-9801 to be ordered separately

1 4

0 5 1 3 0 0 0 0 0

50

CT-513 NACartridge SAE 10

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70

400

350

300

250

200

150

100

50

0

0 10 20 30 40 50 60 70

10

8

6

4

2

0

21

www.nem-hydraulics.com5.01.004

Push pinNo emergency Push Button

Push andTwist

Pres

sure

[ba

r]Pr

essu

re [

bar]

Flow [l/min]

Flow [l/min]

Pressure drop from 2 to 1 and from 1 to 2

Application limits from 2 to 1 and 1 to 2

2 WAYS 2 POSITIONS ELECTRIC VALVE, PILOT POPPET OPERATED NO

Ø38

80,8

32,5

Ø 15,81

2

7/8-14 UNF-2A

Hex.27

Page 11: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

72

Ordering code

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150 l/min• Max working pressure . . . . . . . . . . . . . . . . . . . 350 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 0,25 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C240000• Cartridge thightening torque . . . . . . . . . . . . . . . 50 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil) . . . . . . . . . . . . . . . . . . . . . . . 0,58 Kg• Coil CT-9801 to be ordered separately

Cartridge SAE 12

4

0 5 1 4 0 0 0 0 0

50

CT-514 NA

2 WAYS 2 POSITIONS ELECTRIC VALVE, PILOT POPPET OPERATED NO

0 20 40 60 80 100 120 140 160 180

400

350

300

250

200

150

100

50

0

20 18 16

14

12 10

8

6

4 2

00 20 40 60 80 100 120 140 160 180

21

www.nem-hydraulics.com5.01.005

No emergency Push Button

Push andTwist

Flow [l/min]

Pres

sure

[ba

r]Pr

essu

re [

bar]

Flow [l/min]

Application limits from 2 to 1 and 1 to 2

Pressure drop from 2 to 1 and from 1 to 2

Ø38

78,3

46

Ø 22,25

1

2

1-1/16"-12 UNF2A

Hex.32

Page 12: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

73

Ordering code

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 l/min• Max working pressure . . . . . . . . . . . . . . . . . . . 350 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . .0,25 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NBR • Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C220000 • Cartridge thightening torque. . . . . . . . . . . . . . . .30 Nm• Ring nut thightening torque. . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,32 Kg• Coil CT-9400 to be ordered separately

2 WAYS 2 POSITIONS ELECTRIC VALVE, PILOT POPPET OPERATED NC

0 5 1 2 1 0 0 0 0

0 6

CT-512 NCCartridge SAE 8

0 5 10 15 20 25 30 35 40 45

400

350

300

250

200

150

100

50

0

0 5 10 15 20 25 30 35 40 45 50

8

6

4

2

0

1 2

Unscrew type

www.nem-hydraulics.com5.01.006

No emergency

Pres

sure

[ba

r]Pr

essu

re [

bar]

Flow [l/min]

Flow [l/min]

Application limits from 2 to 1 and 1 to 2

Pressure drop from 2 to 1 and from 1 to 2

Ø45,2

67,3

27,5

Ø 12,7

1

2

16,40

3/4-16 UNF2A

Hex.24

Page 13: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

74

Ordering code

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 l/min• Max working pressure . . . . . . . . . . . . . . . . . . .350 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . .0,25 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NBR • Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C230000 • Cartridge thightening torque. . . . . . . . . . . . . . . .40 Nm• Ring nut thightening torque. . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,56 Kg• Coil CT-9801 to be ordered separately

0 5 1 3 1 0 0 0 0

0 6

CT-513 NC

2 WAYS 2 POSITIONS ELECTRIC VALVE, PILOT POPPET OPERATED NC

Cartridge SAE 10

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70

400

350

300

250

200

150

100

50

0

0 10 20 30 40 50 60 70

10

8

6

4

2

0

1 2

www.nem-hydraulics.com5.01.007

Unscrew typeNo emergency

Flow [l/min]

Pres

sure

[ba

r]Pr

essu

re [

bar]

Flow [l/min]

Pressure drop from 2 to 1 and from 1 to 2

Application limits from 2 to 1 and 1 to 2

Ø38

80,8

31,5

Ø 15,81

2

7/8-14 UNF-2A

Hex.27

Page 14: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

75

Ordering code

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150 l/min• Max working pressure . . . . . . . . . . . . . . . . . . .350 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 0,25 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C240000• Cartridge thightening torque . . . . . . . . . . . . . . . 50 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . 0,58 Kg• Coil CT-9801 to be ordered separately

2 WAYS 2 POSITIONS ELECTRIC VALVE, PILOT POPPET OPERATED NC

0 5 1 4 1 0 0 0 0

0 6

CT-514 NCCartridge SAE 12

0 20 40 60 80 100 120 140 160 180

400

350

300

250

200

150

100

50

0

20 18 16

14

12 10

8

6

4 2

00 20 40 60 80 100 120 140 160 180

1 2

www.nem-hydraulics.com5.01.008

Unscrew typeNo emergency

Pres

sure

[ba

r]Pr

essu

re [

bar]

Flow [l/min]

Flow [l/min]

Pressure drop from 2 to 1 and from 1 to 2

Application limits from 2 to 1 and 1 to 2

Ø 38

78,3

46

Ø 22,25

1

2

1-1/16"-12 UNF2A

Hex.32

Page 15: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

76

Ordering code

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 l/min• Max working pressure in 1. . . . . . . . . . . . . . . . 350 bar• Max working pressure in 2. . . . . . . . . . . . . . . . . 20 bar• Leakage. . . . . . . . . . . . . . . . . . . . . . . . . . .0,25 cc/min• Seals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C220000• Cartridge thightening torque. . . . . . . . . . . . . . . .30 Nm• Ring nut thightening torque. . . . . . . . . . . . . . . . . .5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,32 Kg• Coil CT-9400 to be ordered separately

2 WAYS 2 POSITIONS ELECTRIC VALVE, DIRECT ACTING NO

0 4

0 5 3 2 0 1 0 0 0

5

CT-532 NACartridge SAE 8

0 0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6

20

16

12

8

4

0

1 2

Pressure drop graph 1 in 2

www.nem-hydraulics.com5.01.009

No emergency Push Button

Push andTwist

Flow [l/min]

Pres

sure

[ba

r]

45,2

62,3

27,5

Ø 12,7

1

2

16,40

3/4-16 UNF2A

Hex.24

Page 16: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

77

Ordering code

• Flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 l/min• Max working pressure in 1 . . . . . . . . . . . . . . . .350 bar• Max working pressure in 2 . . . . . . . . . . . . . . . . 20 bar• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C220000• Leakage. . . . . . . . . . . . . . . . . . . . . . . . . . . 0,25 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR• Cartridge thightening torque. . . . . . . . . . . . . . . . .30 Nm• Ring nut thightening torque. . . . . . . . . . . . . . . . . . 5 Nm• Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0,32 Kg• Coil CT-9400 to be ordered separately

CT-532 NCCartridge SAE 8

0 5 3 2 1 1 0 0 0

Note:- Cracking pressure with de-energized coil 1 to 2 at 380 bar.

1 2

0 6

www.nem-hydraulics.com5.01.010

2 WAYS 2 POSITIONS ELECTRIC VALVE, PILOT POPPET OPERATED NC

1

CH 24

2

27,5

12,6

3/4"-16 UNF-2A3/4"-16 UNF2A

7327

,5

Ø 12,6

1

2

Hex.24

Unscrew typeNo emergency

Page 17: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

78

Ordering code

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 l/min• Max working pressure . . . . . . . . . . . . . . . . . . .300 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 0,25 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR • Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C220000 • Cartridge thightening torque . . . . . . . . . . . . . . . 30 Nm• Ring nut thightening torque. . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,32 Kg• Filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280 microm• Coil CT-9300 to be ordered separately

0 5 5 2 5 0 0 0

1

0Without filter With filter

0 4 5

CT-552 NACartridge SAE 8

0 5 10 15 20 25 30 35

350

300

250

200

150

100

50

0

0 5 10 15 20 25 30 35 40 45

20

16

12

8

4

0

1 2

1

2

21

www.nem-hydraulics.com5.01.011/A

No emergency Push Button

Push andTwist

1 = Application limits from 2 to 12 = Application limits from 1 to 2

Flow [l/min]

Pres

sure

[ba

r]Pr

essu

re [

bar]

Flow [l/min]

1 = Pressure drop from 2 to 1 without filter2 = Pressure drop from 2 to 1 with filter

2 WAYS 2 POSITIONS ELECTRIC VALVE, PILOT POPPET OPERATED NO

42

62,7

27,5

Ø 12,7

1

2

20,50

3/4-16 UNF2A

Hex.24

Page 18: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

79

Ordering code

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 l/min• Max working pressure . . . . . . . . . . . . . . . . . . . 350 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 0,25 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR • Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C220000• Cartridge thightening torque. . . . . . . . . . . . . . . . 30 Nm• Ring nut thightening torque. . . . . . . . . . . . . . . . . .5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,32 Kg• Coil CT-9400 to be ordered separately

0 5 5 2 0 0 0 0

0 1

Hydraulic Scheme

0 4 5

Scheme 0 Scheme 1

CT-552 NACartridge SAE 8

0 5 10 15 20 25 30 35 40 45

400

350

300

250

200

150

100

50

0

0 5 10 15 20 25 30 35 40 45 50

8

6

4

2

0

1 2 1 2

www.nem-hydraulics.com5.01.011/B

No emergency Push Button

Push andTwist

Pres

sure

[ba

r]Pr

essu

re [

bar]

Flow [l/min]

Flow [l/min]

Application limits from 1 to 2 and 2 to 1

Pressure drop with energized coil

2 WAYS 2 POSITIONS ELECTRIC VALVE, PILOT POPPET OPERATED NO

45,2

67,3

27,5

Ø 12,6

1

2

16,40

3/4-16 UNF2A

Hex.24

Page 19: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

80

Ordering code

Pres

sure

[ba

r]

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 l/min• Max working pressure . . . . . . . . . . . . . . . . . . .350 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 0,25 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C230000• Cartridge thightening torque. . . . . . . . . . . . . . . 40 Nm• Ring nut thightening torque. . . . . . . . . . . . . . . . . .5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,56 Kg• Coil CT-9801 to be ordered separately

Scheme 0 Scheme 1

0

0 5 5 3 0 0 0 0

0 1

Hydraulic scheme

1 4 5

CT-553 NACartridge SAE 10

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70

400

350

300

250

200

150

100

50

0

0 10 20 30 40 50 60 70

10

8

6

4

2

0

1 2 1 2

www.nem-hydraulics.com5.01.012

Push pinNo emergency Push Button

Push andTwist

Flow [l/min]

Pres

sure

[ba

r]

Flow [l/min]

Pressure drop from 2 to 1 and from 1 to 2

Application limits from 2 to 1 and 1 to 2

2 WAYS 2 POSITIONS ELECTRIC VALVE, PILOT POPPET OPERATED NO

Ø38

80,8

31,5

Ø 15,8

1

2

7/8-14 UNF-2A

Hex.27

Page 20: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

81

Ordering code

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 l/min• Max working pressure . . . . . . . . . . . . . . . . . . . . 350 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,25 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NBR • Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C240000• Cartridge thightening torque. . . . . . . . . . . . . . . . .50 Nm• Ring nut thightening torque. . . . . . . . . . . . . . . . . . .5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . . 0,56 Kg• Coil CT-9801 to be ordered separately

Scheme 0 Scheme 1

0

0 5 5 4 0 0 0 0

0 1 4 5

CT-554 NACartridge SAE 12

0 20 40 60 80 100 120 140 160 180

400

350

300

250

200

150

100

50

0

0 20 40 60 80 100 120 140 160 180

20 18 16

14

12 10

8

6

4 2

0

1 2 1 2

www.nem-hydraulics.com5.01.013

No emergency Push Button

Push andTwist

Hydraulic scheme

Pres

sure

[ba

r]Pr

essu

re [

bar]

Flow [l/min]

Flow [l/min]

Application limits from 1 in 2 and 2 in 1

Pressure drop with energized coil

2 WAYS 2 POSITIONS ELECTRIC VALVE, PILOT POPPET OPERATED NO

Ø 38

78,3

46

Ø 22,25

1

2

1-1/16"-12 UNF2A

Hex.32

Page 21: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

82

Ordering code

CT-565 NA

• Flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .200 l/min• Max working pressure. . . . . . . . . . . . . . . . . . . . 350 bar• Leakage. . . . . . . . . . . . . . . . . . . . . . . . . . . 0,25 cc/min• Seals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C250000• Cartridge thightening torque . . . . . . . . . . . . . . . . 65 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . .5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . . 0,58 Kg• Coil CT-9400 to be ordered separately

Cartridge SAE 16

0 5 6 5 0 0 0 0 0

0 4 5

0 20 40 60 80 100 120 140 160 180 200

18

15

12

9

6

3

0

1 > 2

2 > 1

www.nem-hydraulics.com5.01.014

No emergency Push Button

Push andTwist

Flow [l/min]

Pres

sure

[ba

r]

Application limits from 1 in 2 and 2 in 1

2 WAYS 2 POSITIONS ELECTRIC VALVE, PILOT POPPET OPERATED NO

1" 5/16-12 UN-2A

28,5

44,5

74,8

1

2

Hex.38

1 2

Page 22: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

83

Ordering code

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 l/min• Max working pressure . . . . . . . . . . . . . . . . . . . 300 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 0,25 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR • Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C220000 • Cartridge thightening torque. . . . . . . . . . . . . . . . 30 Nm• Ring nut thightening torque. . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,32 Kg• Filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280 microm• Coil CT-9300 to be ordered separately

0 5 5 2 6 0 0 0

1

00 6

CT-552 NCCartridge SAE 8

0 5 10 15 20 25 30 35

350

300

250

200

150

100

50

0

0 5 10 15 20 25 30 35 40 45

20

16

12

8

4

0

1 2

1

2

21

www.nem-hydraulics.com5.01.015/A

Unscrew typeNo emergency

Without filter With filter

1 = Application limits from 2 to 1 without filter2 = Application limits with filter

1 = Pressure drop from 2 to 1 without filter2 = Pressure drop from 2 to 1 with filter

Pres

sure

[ba

r]Pr

essu

re [

bar]

Flow [l/min]

Flow [l/min]

2 WAYS 2 POSITIONS ELECTRIC VALVE, PILOT POPPET OPERATED NO

42

62,7

27,5

Ø 12,7

1

2

20,50

3/4-16 UNF2A

Hex.24

Page 23: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

84

Ordering code

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 l/min• Max working pressure . . . . . . . . . . . . . . . . . . . 350 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 0,25 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C220000 • Cartridge thightening torque . . . . . . . . . . . . . . . .30 Nm• Ring nut thightening torque. . . . . . . . . . . . . . . . . .5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,32 Kg• Coil CT-9400 to be ordered separately

Scheme 0 Scheme 1

0

0 5 5 2 1 0 0 0

0 1 6

CT-552 NCCartridge SAE 8

0 5 10 15 20 25 30 35 40 45 50

400

350

300

250

200

150

100

50

0

0 5 10 15 20 25 30 35 40 45 50

8

6

4

2

0

1 2 1 2

www.nem-hydraulics.com5.01.015/B

Hydraulic scheme

Unscrew typeNo emergency

Pres

sure

[ba

r]

Flow [l/min]

Pres

sure

[ba

r]

Flow [l/min]

Pressure drop from 2 to 1 and from 1 to 2

Application limits from 2 to 1 and 1 to 2

2 WAYS 2 POSITIONS ELECTRIC VALVE, PILOT POPPET OPERATED NO

45,2

67,3

27,5

Ø 12,6

1

2

16,40

3/4-16 UNF2A

Hex.24

Page 24: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

85

Ordering code

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 l/min• Max working pressure . . . . . . . . . . . . . . . . . . . 350 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 0,25 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NBR • Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C230000 • Cartridge thightening torque. . . . . . . . . . . . . . . .40 Nm• Ring nut thightening torque. . . . . . . . . . . . . . . . . .5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,56 Kg• Coil CT-9801 to be ordered separately

Scheme 0 Scheme 1

0

0 5 5 3 1 0 0 0

0 1 6

CT-553 NCCartridge SAE 10

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70

400

350

300

250

200

150

100

50

0

0 10 20 30 40 50 60 70

10

8

6

4

2

0

1 2 1 2

www.nem-hydraulics.com5.01.016

Hydraulic scheme

Unscrew typeNo emergency

Pres

sure

[ba

r]Pr

essu

re [

bar]

Flow [l/min]

Flow [l/min]

Application limits from 2 to 1 and 1 to 2

Pressure drop from 2 to 1 and from 1 to 2

2 WAYS 2 POSITIONS ELECTRIC VALVE, PILOT POPPET OPERATED NC

Ø38

80,8

31,5

Ø 15,8

1

2

7/8-14 UNF-2A

Hex.27

Page 25: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

86

Ordering code

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 l/min• Max working pressure. . . . . . . . . . . . . . . . . . . . 350 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . .0,25 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NBR • Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C240000• Cartridge thightening torque . . . . . . . . . . . . . . . . 50 Nm• Ring nut thightening torque. . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . . 0,58 Kg• Coil CT-9801 to be ordered separately

Scheme 0 Scheme 1

0

0 5 5 4 1 0 0 0

0 1 6

CT-554 NCCartridge SAE 12

0 20 40 60 80 100 120 140 160 180

400

350

300

250

200

150

100

50

0

0 20 40 60 80 100 120 140 160 180

20 18 16

14

12 10

8

6

4 2

0

1 2 1 2

www.nem-hydraulics.com5.01.017

Hydraulic scheme

Unscrew typeNo emergency

Pres

sure

[ba

r]

Flow [l/min]

Pres

sure

[ba

r]

Flow [l/min]

Pressure drop from 2 to 1 and from 1 to 2

Application limits from 2 to 1 and 1 to 2

2 WAYS 2 POSITIONS ELECTRIC VALVE, PILOT POPPET OPERATED NC

Ø 38

78,3

46

Ø 22,25

1

2

1-1/16"-12 UNF2A

Hex.32

Page 26: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

87

Ordering code

CT-565 NC

• Flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .200 l/min• Max working pressure. . . . . . . . . . . . . . . . . . . . 350 bar• Leakage. . . . . . . . . . . . . . . . . . . . . . . . . . . 0,25 cc/min• Seals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C250000• Cartridge thightening torque. . . . . . . . . . . . . . . . 65 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . . 0,58 Kg• Coil CT-9400 to be ordered separately

Cartridge SAE 16

0 5 6 5 1 0 0 0 0

0 6

1 > 2

2 < 1

0 20 40 60 80 100 120 140 160 180 200

18

15

12

9

6

3

0

www.nem-hydraulics.com5.01.018

Unscrew typeNo emergency

Pres

sure

[ba

r]

Flow [l/min]

2 WAYS 2 POSITIONS ELECTRIC VALVE, PILOT POPPET OPERATED NC

28,5

44,5

74,8

1" 5/16-12 UN-2A

1

2

74,8

Hex.38

1 2

Page 27: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

88

Ordering code

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 l/min• Max working pressure . . . . . . . . . . . . . . . . . . . 300 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . .0,25 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NBR • Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ,C220000• Cartridge thightening torque . . . . . . . . . . . . . . . .30 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . . 0,32 Kg• Filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .280 microm• Coil CT-9300 to be ordered separately

0 5 6 2 5 0 0 0

1

00 4 5

CT-562 NACartridge SAE 8

1

2

0 5 10 15 20 25 30 35

350

300

250

200

150

100

50

0

2

1

0 5 10 15 20 25 30 35 40 45

20

16

12

8

4

0

1 2

www.nem-hydraulics.com5.01.019/A

Without filter With filter

No emergency Push Button

Push andTwist

1 = Application limits from 2 to 12 = Application limits from 1 to 2

1 = Pressure drop from 2 to 1 without filter2 = Pressure drop from 2 to 1 with filter

Pres

sure

[ba

r]

Flow [l/min]

Pres

sure

[ba

r]

Flow [l/min]

2 WAYS 2 POSITIONS ELECTRIC VALVE, PILOT POPPET OPERATED NO

42

62,7

27,5

Ø 12,7

1

2

20,50

3/4-16 UNF2A

Hex.24

Page 28: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

89

Ordering code

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 l/min• Max working pressure . . . . . . . . . . . . . . . . . . . 350 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 0,25 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C220000 • Cartridge thightening torque. . . . . . . . . . . . . . . . 30 Nm• Ring nut thightening torque. . . . . . . . . . . . . . . . . .5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,32 Kg• Coil CT-9400 to be ordered separately

2 WAYS 2 POSITIONS ELECTRIC VALVE, PILOT POPPET OPERATED NO

0 4

0 5 6 2 0 0 0 0 0

5

CT-562 NACartridge SAE 8

0 5 10 15 20 25 30 35 40 45

400

350

300

250

200

150

100

50

0

0 5 10 15 20 25 30 35 40 45 50

8

6

4

2

0

1 2

www.nem-hydraulics.com5.01.019/B

No emergency Push Button

Push andTwist

Pres

sure

[ba

r]

Flow [l/min]

Pres

sure

[ba

r]

Flow [l/min]

Application limits from 2 to 1 and 1 to 2

Pressure drop from 2 to 1 and from 1 to 2

45,2

Ø 12,6

1

2

16,40

67,3

27,5

3/4-16 UNF2A

Hex.24

Page 29: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

90

Ordering code

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 l/min• Max working pressure . . . . . . . . . . . . . . . . . . . 350 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,25 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C230000• Cartridge thightening torque. . . . . . . . . . . . . . . . . 40 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . . 0,56 Kg• Coil CT-9801 to be ordered separately

1 4

0 5 6 3 0 0 0 0 0

50

CT-563 NACartridge SAE 10

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70

400

350

300

250

200

150

100

50

0

0 10 20 30 40 50 60 70

10

8

6

4

2

0

1 2

www.nem-hydraulics.com5.01.020

Push pinNo emergency Push Button

Push andTwist

Pres

sure

[ba

r]

Flow [l/min]

Pres

sure

[ba

r]

Flow [l/min]

Pressure drop from 2 to 1 and from 1 to 2

Application limits from 2 to 1 and 1 to 2

2 WAYS 2 POSITIONS ELECTRIC VALVE, PILOT POPPET OPERATED NO

7/8-14 UNF2A

Ø38

80,8

31,5

Ø 15,81

2

Hex.27

Page 30: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

91

Ordering code

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 l/min• Max working pressure . . . . . . . . . . . . . . . . . . . 350 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,25 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C240000• Cartridge thightening torque. . . . . . . . . . . . . . . . .50 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . . 0,58 Kg• Coil CT-9801 to be ordered separately

0 4

0 5 6 4 0 0 0 0 0

5

CT-564 NACartridge SAE 12

0 20 40 60 80 100 120 140 160 180

400

350

300

250

200

150

100

50

0

0 20 40 60 80 100 120 140 160 180

20 18 16

14

12 10

8

6

4 2

0

1 2

www.nem-hydraulics.com5.01.021

No emergency Push Button

Push andTwist

Pres

sure

[ba

r]

Flow [l/min]

Pres

sure

[ba

r]

Flow [l/min]

Application limits from 2 to 1 and 1 to 2

Pressure drop from 2 to 1 and from 1 to 2

2 WAYS 2 POSITIONS ELECTRIC VALVE, PILOT POPPET OPERATED NO

Ø38

Ø 22,25

1

2

78,3

46

1-1/16"-12 UNF2A

Hex.32

Page 31: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

92

Ordering code

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 l/min• Max working pressure . . . . . . . . . . . . . . . . . . . 300 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . .0,25 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NBR • Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C220000 • Cartridge thightening torque. . . . . . . . . . . . . . . . .30 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . . 0,32 Kg• Filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .280 microm• Coil CT-9300 to be ordered separately

0 5 6 2 6 0 0 0

1

00 6

CT-562 NCCartridge SAE 8

1

2

0 5 10 15 20 25 30 35

350

300

250

200

150

100

50

0

2

1

0 5 10 15 20 25 30 35 40 45

20

16

12

8

4

0

1 2

www.nem-hydraulics.com5.01.022/A

Unscrew typeNo emergency

Without filter With filter

Pres

sure

[ba

r]

Flow [l/min]

Pres

sure

[ba

r]

Flow [l/min]

1 = Application limits from 2 to 12 = Application limits from 1 to 2

1 = Pressure drop from 2 to 1 without filter2 = Pressure drop from 2 to 1 with filter

2 WAYS 2 POSITIONS ELECTRIC VALVE, PILOT POPPET OPERATED NC

Ø42

62,7

27,5

Ø 12,7

1

2

20,50

3/4-16 UNF2A

Hex.24

Page 32: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

93

Ordering code

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 l/min• Max working pressure. . . . . . . . . . . . . . . . . . . .350 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 0,25 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C220000• Cartridge thightening torque. . . . . . . . . . . . . . . . 30 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,32 Kg• Coil CT-9400 to be ordered separately

CT-562 NCCartridge SAE 8

0 5 10 15 20 25 30 35 40 45

400

350

300

250

200

150

100

50

0 5 10 15 20 25 30 35 40 45 50

8

6

4

2

www.nem-hydraulics.com5.01.022/B

Unscrew typeNo emergency

Pres

sure

[ba

r]

Flow [l/min]

Pres

sure

[ba

r]

Flow [l/min]

Application limits from 2 to 1 and 1 to 2

Pressure drop from 2 to 1 and from 1 to 2

2 WAYS 2 POSITIONS ELECTRIC VALVE, PILOT POPPET OPERATED NC

0

0 5 6 2 1 0 0 0

0 1 6

1 2 12

Scheme 0 Scheme 1

Hydraulic scheme

45,2

Ø 12,6

1

2

16,40

67,3

27,5

3/4-16 UNF2A

Hex.24

Page 33: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

94

Ordering code

0 5 6 3 1 0 0 0 0

0 6

CT-563 NCCartridge SAE 10

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70

400

350

300

250

200

150

100

50

0

0 10 20 30 40 50 60 70

10

8

6

4

2

0

1 2

www.nem-hydraulics.com5.01.023

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 l/min• Max working pressure . . . . . . . . . . . . . . . . . . . 350 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . .0,25 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NBR • Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C230000 • Cartridge thightening torque. . . . . . . . . . . . . . . . .40 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . . 0,56 Kg• Coil CT-9801 to be ordered separately

Unscrew typeNo emergency

Pres

sure

[ba

r]

Flow [l/min]

Pres

sure

[ba

r]

Flow [l/min]

Pressure drop from 2 to 1 and from 1 to 2

Application limits from 2 to 1 and 1 to 2

2 WAYS 2 POSITIONS ELECTRIC VALVE, PILOT POPPET OPERATED NC

Ø38

80,8

31,5

Ø 15,81

2

7/8-14 UNF-2A

Hex.27

Page 34: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

95

Ordering code

0 5 6 4 1 0 0 0 0

0 6

CT-564 NCCartridge SAE 12

0 20 40 60 80 100 120 140 160 180

400

350

300

250

200

150

100

50

0

0 20 40 60 80 100 120 140 160 180

20 18 16

14

12 10

8

6

4 2

0

1 2

www.nem-hydraulics.com5.01.024

Unscrew typeNo emergency

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150 l/min• Max working pressure. . . . . . . . . . . . . . . . . . . .350 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 0,25 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C240000• Cartridge thightening torque. . . . . . . . . . . . . . . . 50 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,58 Kg• Coil CT-9801 to be ordered separately

Pres

sure

[ba

r]

Flow [l/min]

Pres

sure

[ba

r]

Flow [l/min]

Application limits from 2 to 1 and 1 to 2

Pressure drop from 2 to 1 and from 1 to 2

2 WAYS 2 POSITIONS ELECTRIC VALVE, PILOT POPPET OPERATED NC

Ø38

Ø 22,25

1

2

78,3

46

1-1/16"-12 UNF2A

Hex.32

Page 35: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

96

Ordering code

• Max working flow (P in port 1) . . . . . . . . . . . . . . 6 l/min• Max working flow (P in port 2) . . . . . . . . . . . . . 15 l/min• Max working flow (P in port 3) . . . . . . . . . . . . .5,5 l/min• Max working pressure. . . . . . . . . . . . . . . . . . . . 250 bar• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C320000• Max Leakage at 250 bar. . . . . . . . . . . . . . . . 40 cc/min• Seals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NBR• Cartridge thightening torque. . . . . . . . . . . . . . . . .30 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . .5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . . 0,35 Kg• Coil CT-9400 to be ordered separately

CT-402.1

3 WAYS 2 POSITIONS ELECTRIC SPOOL VALVE, DIRECT ACTING

Cartridge SAE 8

0 4 0 2 1 0 0 0 0

0 4 5

3

2

1

www.nem-hydraulics.com5.01.025

No emergency Push Button

Push andTwist

1

2

CH 24

63,1

15,8

3/4"-16-UNF-2A

14,2

39,5

3/4"-16-UNF-2A

63,1

39,5 Ø 15,8

1

2

3

Ø 14,2

Hex.24

Page 36: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

97

Ordering code

CT-402.3 BP

3 WAYS 2 POSITIONS ELECTRIC SPOOL VALVE, DIRECT ACTING - LOW PRESSURE -

Cartridge SAE 8

0 4 0 2 3 1 0 0 0 1

3

2

1

2

1

0 1 2 3 4 5 6

10

8

6

4

2

0

www.nem-hydraulics.com5.01.026

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 l/min• Max working pressure. . . . . . . . . . . . . . . . . . . . 50 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C320000• Cartridge thightening torque. . . . . . . . . . . . . . . . 30 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,35 Kg• Coil CT-9400 to be ordered separately

Pres

sure

[ba

r]

Flow [l/min]1 = Pressure drop from 2 in 12 = Pressure drop from 3 in 1

1

2

CH 24

3

63,1

15,8

3/4"-16-UNF-2A

14,2

39,5

3/4"-16-UNF-2A

Ø 15,8

1

2

63,1

39,5

Ø 14,2

Hex.24

Page 37: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

98

Ordering code

CT-402.3Cartridge SAE 8

0 4 0 2 3 0 0 0 0

0 4 5

3

2

1

www.nem-hydraulics.com5.01.027

• Max working flow (P in port 1) . . . . . . . . . . . . . . 7 l/min• Max working flow (P in port 2) . . . . . . . . . . . . . 15 l/min• Max working flow (P in port 3) . . . . . . . . . . . . . 15 l/min• Max working pressure. . . . . . . . . . . . . . . . . . . . 250 bar• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C320000• Max Leakage at 250 bar. . . . . . . . . . . . . . . . 40 cc/min• Seals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NBR• Cartridge thightening torque. . . . . . . . . . . . . . . . .30 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . .5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . . 0,35 Kg• Coil CT-9400 to be ordered separately

No emergency Push Button

Push andTwist

3 WAYS 2 POSITIONS ELECTRIC SPOOL VALVE, DIRECT ACTING

2

1

CH 24

3

63,1

3/4"-16-UNF-2A

15,8

14,2

39,5

3/4"-16-UNF-2A

63,1

39,5 Ø 15,8

Ø 14,2

Hex.24

Page 38: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

99

Ordering code

CT-402.4Cartridge SAE 8

0 4 0 2 4 0 0 0 0

0 4 5

3

2

1

www.nem-hydraulics.com5.01.028

• Max working flow (P in port 1) . . . . . . . . . . . . . . 7 l/min• Max working flow (P in port 2) . . . . . . . . . . . . . 15 l/min• Max working flow (P in port 3) . . . . . . . . . . . . . 15 l/min• Max working pressure. . . . . . . . . . . . . . . . . . . . 250 bar• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C320000• Max Leakage at 250 bar. . . . . . . . . . . . . . . . 40 cc/min• Seals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NBR• Cartridge thightening torque. . . . . . . . . . . . . . . . .30 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . .5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . . 0,35 Kg• Coil CT-9400 to be ordered separately

No emergency Push Button

Push andTwist

3 WAYS 2 POSITIONS ELECTRIC SPOOL VALVE, DIRECT ACTING

2

1

CH 24

3

3/4"-16-UNF-2A

15,8

63,1

14,2

39,5

3/4"-16-UNF-2A

Ø 15,8

63,1

39,5

Ø 14,2

Hex.24

Page 39: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

100

Ordering code

CT-402.2 Cartridge SAE 8

0 4 0 2 2 0 0 0 0

0 4 5

3

2

1

www.nem-hydraulics.com5.01.029

• Max working flow (P in port 1) . . . . . . . . . . . . . . 7 l/min• Max working flow (P in port 2) . . . . . . . . . . . .13,5 l/min• Max working flow (P in port 3) . . . . . . . . . . . . .5,5 l/min• Max working pressure. . . . . . . . . . . . . . . . . . . . 250 bar• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C320000• Max Leakage at 250 bar. . . . . . . . . . . . . . . . 40 cc/min• Seals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NBR• Cartridge thightening torque. . . . . . . . . . . . . . . . .30 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . .5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . . 0,35 Kg• Coil CT-9400 to be ordered separately

No emergency Push Button

Push andTwist

3 WAYS 2 POSITIONS ELECTRIC SPOOL VALVE, DIRECT ACTING

2

1

CH 24

3 15,8

3/4"-16-UNF-2A

63,1

14,2

39,5

3/4"-16-UNF-2A

63,1

39,5 Ø 15,8

Ø 14,2

Hex.24

Page 40: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

101

Ordering code

Cartridge SAE 10

0 1 7

Handknob

0 4 0 3 2 0 0 0 0

5

CT-403.2

0 5 10 15 20 25 30

15

10

5

0

0 5 10 15 20 25 30

300

250

200

150

100

50

0

3

2

1

2

1

www.nem-hydraulics.com5.01.030

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 l/min• Max working pressure. . . . . . . . . . . . . . . . . . . .250 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . .100 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C330000• Cartridge thightening torque. . . . . . . . . . . . . . . . 40 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,56 Kg• Coil CT-9801 to be ordered separately

No emergency Push andTwist

Pres

sure

[ba

r]

Flow [l/min]

Pres

sure

[ba

r]

Flow [l/min]

1 = Pressure drop from 2 in 12 = Pressure drop from 3 in 2

Application limits from 2 in 1 and 2 in 3

3 WAYS 2 POSITIONS ELECTRIC SPOOL VALVE, DIRECT ACTING

Push pin

Ø38

Ø 15,8

1

2

80,5

46 Ø17,40

3

7/8-14 UNF-2A

Hex.27

Page 41: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

102

Ordering code

Cartridge SAE 12

0 1 7

0 4 0 4 2 0 0 0 0

5

CT-404.2

0 10 20 30 40 50 60

20

15

10

5

0

0 10 20 30 40 50 60

300

250

200

150

100

50

0

3

2

1

www.nem-hydraulics.com5.01.031

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 l/min• Max working pressure in 1:2:3 . . . . . . . . . . . . .350 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 150 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C340000• Cartridge thightening torque. . . . . . . . . . . . . . . . 50 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,70 Kg• Coil CT-9800 to be ordered separately

HandknobNo emergency Push andTwist

Pres

sure

[ba

r]

Flow [l/min]

Pres

sure

[ba

r]

Flow [l/min]

1 = Pressure drop from 2 in 12 = Pressure drop from 3 in 2

Application limits from 2 in 1 and 2 in 3

3 WAYS 2 POSITIONS ELECTRIC SPOOL VALVE, DIRECT ACTING

Push pin

Ø38

9869

,5

Ø 22,25

1

2Ø 23,82

3

1-1/16"-12 UNF2A

Hex.32

2

1

Page 42: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

103

Ordering code

3 WAYS 2 POSITIONS ELECTRIC ON/OFF POPPET VALVE DIRECT ACTING

0 4 2 3 2 0 0 0 0

CT-423.2

0 1 75

Cartridge SAE 10

0 5 10 15 20 25 30 35

400

350

300

250

200

150

100

50

0

0 5 10 15 20 25 30 35 40

40

35

30

25

20

15

10

5

0

3

2

1

21

1

2

www.nem-hydraulics.com5.01.032

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 l/min• Max working pressure in 3:2:1 . . . . . . . . . . . . .350 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 0,25 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C330000• Cartridge thightening torque. . . . . . . . . . . . . . . . 40 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,56 Kg• Coil CT-9800 to be ordered separately

HandknobNo emergency Push andTwist

1 = Application limits from 1 to 2 and 2 to 12 = Application limits from 2 to 3 and 3 to 2

1 = Pressure drop from 2 to 3 and 3 to 22 = Pressure drop from 1 to 2 and 2 to 1

Pres

sure

[ba

r]

Flow [l/min]

Pres

sure

[ba

r]

Flow [l/min]

Push pin

Ø38

Ø 15,8

80,3

46

Ø 17,4

7/8-14 UNF-2A

Hex.27

Page 43: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

104

Ordering code

Cartridge SAE 8

Scheme 2 Scheme 3

0 4

5

2 3

CT-412

2

1

0 2 4 6 8 10 12

16

12

8

4

0

0 2 4 6 8 10 12

300

250

200

150

100

50

0

4

3

2

1 1

24

3

www.nem-hydraulics.com5.01.033

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 l/min• Max working pressure . . . . . . . . . . . . . . . . . . . 210 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C420000• Cartridge thightening torque. . . . . . . . . . . . . . . . 30 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,35 Kg• Coil CT-9400 to be ordered separately

Hydraulic scheme

No emergency Push Button

Push andTwist

Pres

sure

[ba

r]

Flow [l/min]

Pres

sure

[ba

r]

Flow [l/min]

1 = Pressure drop from 2/4 to 32 = Pressure drop from 3 to 2/4

Application limits from 3 in 2/4

4 WAYS 2 POSITIONS ELECTRIC ON/OFF SPOOL VALVE DIRECT ACTING

16,40

6253

,4

Ø 12,6

1

2

Ø 15,83

Ø 14,2

4

3/4-16 UNF2A

Hex.24

0 4 1 2 0 0 0 0

Page 44: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

105

Ordering code

Cartridge SAE 10

0 4 1 3 0 0 0 0

2 3

Scheme 2 Scheme 3

CT-413.2

0 1 75

0 5 10 15 20 25 30

300

250

200

150

100

50

0

5 10 15 20 25 30 35

20

15

10

5

0

4

3

2

1 1

24

3

www.nem-hydraulics.com5.01.034

Hydraulic scheme

HandknobNo emergency Push andTwist

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 l/min• Max working pressure . . . . . . . . . . . . . . . . . . . 250 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 100 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C430000• Cartridge thightening torque. . . . . . . . . . . . . . . . 40 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,56 Kg• Coil CT-9801 to be ordered separately

Pres

sure

[ba

r]

Flow [l/min]

Pres

sure

[ba

r]

Flow [l/min]

Application limits from 3 in 2/4

Pressure drop from 3 to 2/4

4 WAYS 2 POSITIONS ELECTRIC ON/OFF SPOOL VALVE DIRECT ACTING

Push pin

Ø38

Ø 19

8162

Ø 17,4

Ø 15,8

1

2

3

4

7/8-14 UNF-2A

Hex.27

Page 45: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

106

Ordering code

Cartridge SAE 8

0 4 6 2 1 0 0 0 0

S2S1

CT-462.1

0 2 4 6 8 10

16

12

8

4

0

0 2 4 6 8 10 12

250

200

150

100

50

0

3

4 2

1

www.nem-hydraulics.com5.01.035

No emergency Push Button

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 l/min• Max working pressure in 2:3:4. . . . . . . . . . . . . 210 bar• Max working pressure in 1. . . . . . . . . . . . . . . . .20 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C420000• Cartridge thightening torque. . . . . . . . . . . . . . . . 40 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,70 Kg• Coil CT-9400 to be ordered separately

Pres

sure

[ba

r]

Flow [l/min]

Pres

sure

[ba

r]

Flow [l/min]

1 = Pressure drop from 2/4 to 32 = Pressure drop from 3 to 2/4

Application limits from 3 in 2/4

2

1

4 WAYS 3 POSITIONS ELECTRIC SPOOL VALVE DIRECT ACTING

16,40

103

53,4

Ø 12,6

1

2

Ø 15,83

Ø 14,2

4

S2

S1

3/4-16 UNF2A

Hex.24

0 4

Page 46: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

107

Ordering code

Cartridge SAE 10

0 4 6 3 0 0 0 0

1 0 3

CT-463.1

Safety lever

1

2

5 10 15 20 25 30

20

15

10

5

0

0 5 10 15 20 25 30

300

250

200

150

100

50

0

S2S1

3

4 2

1

1

2

www.nem-hydraulics.com5.01.036

Hydraulic scheme

No emergency

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 l/min• Max working pressure in 2:3:4. . . . . . . . . . . . . 250 bar• Max working pressure in 1. . . . . . . . . . . . . . . . . 20 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 100 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C430000• Cartridge thightening torque. . . . . . . . . . . . . . . . 40 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . . 0,9 Kg• Coil CT-9801 to be ordered separately

Pres

sure

[ba

r]

Flow [l/min]

Pres

sure

[ba

r]

Flow [l/min]

1 = Pressure drop graph from 3 to 2 or 42 = Pressure drop graph from 2 or 4 in 1

Application limits from 3 to 4 or 2

4 WAYS 3 POSITIONS ELECTRIC ON/OFF SPOOL VALVE DIRECT ACTING

Ø38

Ø 19

122

62

Ø 17,4

Ø 15,8

1

2

3

4

S2

S1

7/8-14 UNF-2A

Hex.27

Page 47: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

108

Ordering code

Cartridge SAE 8

0 4 6 2 2 0 0 0 0

S2S1

CT-462.2

0 2 4 6 8 10

16

12

8

4

0

0 2 4 6 8 10 12

250

200

150

100

50

0

3

4 2

1

www.nem-hydraulics.com5.01.037

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 l/min• Max working pressure in 2:3:4. . . . . . . . . . . . . 210 bar• Max working pressure in 1. . . . . . . . . . . . . . . . .20 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C420000• Cartridge thightening torque. . . . . . . . . . . . . . . . 30 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,70 Kg• Coil CT-9400 to be ordered separately

Pres

sure

[ba

r]

Flow [l/min]

Pres

sure

[ba

r]

Flow [l/min]

2

1

1 = Pressure drop from 2/4 to 32 = Pressure drop from 3 to 2/4

Application limits from 3 in 2/4

4 WAYS 3 POSITIONS ELECTRIC ON/OFF SPOOL VALVE DIRECT ACTING

16,40

103

53,4

Ø 12,6

1

2

Ø 15,83

Ø 14,2

4

S2

S1

3/4-16 UNF2A

Hex.24

No emergency Push Button

0 4

Page 48: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

109

Ordering code

Cartridge SAE 10

0 4 6 3 0 0 0 0

2 0 3

S2S1

CT-463.2

5 10 15 20 25 30

20

15

10

5

0

0 5 10 15 20 25 30

300

250

200

150

100

50

0

3

4 2

1

1

2

www.nem-hydraulics.com5.01.038

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 l/min• Max working pressure in 2:3:4. . . . . . . . . . . . . 250 bar• Max working pressure in 1. . . . . . . . . . . . . . . . . 20 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 100 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C430000• Cartridge thightening torque. . . . . . . . . . . . . . . . 40 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . . 0,9 Kg• Coil CT-9801 to be ordered separately

Hydraulic scheme

Safety leverNo emergency

Pres

sure

[ba

r]

Flow [l/min]

Pres

sure

[ba

r]

Flow [l/min]

1 = Pressure drop graph from 3 to 2 or 42 = Pressure drop graph from 2 or 4 in 1

Application limits from 3 to 4 or 2

Application limits from 1 in 2 and 2 in 1

4 WAYS 3 POSITIONS ELECTRIC ON/OFF SPOOL VALVE DIRECT ACTING

Ø38

Ø 19

122

62

Ø 17,4

Ø 15,8

1

2

3

4

S2

S1

7/8-14 UNF-2A

Hex.27

Page 49: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

110

Ordering code

Cartridge SAE 8CT-462.3

0 4 6 2 3 0 0 0 0

S1S2

3

4 2

1

www.nem-hydraulics.com5.01.039

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 l/min• Max working pressure in 2:3:4. . . . . . . . . . . . . 210 bar• Max working pressure in 1. . . . . . . . . . . . . . . . .20 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C420000• Cartridge thightening torque. . . . . . . . . . . . . . . . 30 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,20 Kg• Coil CT-9400 to be ordered separately

4 WAYS 2 POSITIONS ELECTRIC ON/OFF SPOOL VALVE DIRECT ACTING

4

1

2

CH 24

3

3/4"-16 UNF-2A

12,6

104

53,5 15,8

14,2

104

53,5

1

2

Ø 15,83

Ø 14,2

4

Ø 12,6

3/4-16 UNF2A

Hex.24

No emergency Push Button

0 4

Page 50: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

111

Ordering code

0 4 6 3 0 0 0 0

3 0 3

S1S2

CT-463.3Cartridge SAE 10

5 10 15 20 25 30

20

15

10

5

0

0 5 10 15 20 25 30

300

250

200

150

100

50

0

3

4 2

1

www.nem-hydraulics.com5.01.040

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 l/min• Max working pressure in 2:3:4. . . . . . . . . . . . . 250 bar• Max working pressure in 1. . . . . . . . . . . . . . . . . 20 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 100 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C430000• Cartridge thightening torque. . . . . . . . . . . . . . . . 40 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . . 0,9 Kg• Coil CT-9801 to be ordered separately

Hydraulic scheme

Safety leverNo emergency

Pres

sure

[ba

r]

Flow [l/min]

Pres

sure

[ba

r]

Flow [l/min]

1 = Pressure drop graph from 3 to 1

Application limits from 3 to 4 or 2

4 WAYS 3 POSITIONS ELECTRIC ON/OFF SPOOL VALVE DIRECT ACTING

Ø38

Ø 19

122

62

Ø 17,4

Ø 15,8

1

2

3

4

S2

S1

7/8-14 UNF-2A

Hex.27

Page 51: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

112

Ordering code

Cartridge SAE 8CT-462.4

0 4 6 2 4 0 0 0 0

24

13

S1S2

www.nem-hydraulics.com5.01.041

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 l/min• Max working pressure in 2:3:4. . . . . . . . . . . . . 210 bar• Max working pressure in 1. . . . . . . . . . . . . . . . .20 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C420000• Cartridge thightening torque. . . . . . . . . . . . . . . . 30 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . . .0,7 Kg• Coil CT-9400 to be ordered separately

4 WAYS 2 POSITIONS ELECTRIC ON/OFF SPOOL VALVE DIRECT ACTING

1

2

CH 24

3

3/4"-16 UNF-2A

53,5 15,8

104

12,6

14,2

4

3/4-16 UNF2A

104

53,5

1

2

Ø 15,83

Ø 14,2

4

Ø 12,6

Hex.24

No emergency Push Button

0 4

Page 52: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

113

Ordering code

CT-463.4Cartridge SAE 10

0 4 6 3 4 0 0 0 0

24

13

S1S2

www.nem-hydraulics.com5.01.042

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 l/min• Max working pressure in 2:3:4. . . . . . . . . . . . . 250 bar• Max working pressure in 1. . . . . . . . . . . . . . . . . 20 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 100 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C430000• Cartridge thightening torque. . . . . . . . . . . . . . . . 40 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . . 0,9 Kg• Coil CT-9801 to be ordered separately

4 WAYS 2 POSITIONS ELECTRIC ON/OFF SPOOL VALVE DIRECT ACTING

Ø38

Ø 19

122

62

Ø 17,4

Ø 15,8

1

2

3

4

S2

S1

7/8-14 UNF-2A

Hex.27

0 3

Safety leverNo emergency

Page 53: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

114

www.nem-hydraulics.com

PROPORTIONAL VALVES

ELECTRIC CARTRIDGES

ELECTRIC CARTRIDGES

PROPORTIONAL VALVES

Page 54: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

115

Proportional controller or amplifier: electronic device converting a low - power input signal into an output signal capable of operating the valve. This output signal can be modified to include PWM ramping or dither.

Ramping: a system for adjustment of output current variation of a proportional control.Compensator: hydraulic device combined to proportional control valves to provide fixed outlet flow when

pressure change.Voltage: current flow potential in an electric circuit. It is measured in units called volts (and is sometimes

abbreviated V). Generally, higher voltage will induce a higher current.

PROPORTIONAL PRESENTATION

NEM is pleased to present its new line of proportional flow pressure regulators. These new valves are equipped, with proportional solenoid controls and provide for continuos flow and pres-sure controls by adjustment of the valve openings to the different values resulting from the amount of energy to the solenoids.The proportional cartridges are seated in standard cavities and can be connected to various types of com-pensators to obtain schemes as shown further on in this catalogue. Proportional flow control cartrigde must be operated by the discharge tube.Following is a glossary of technical terms as used in this catalogue.Current: electrons flow produced by voltage across a coil whose power is proportional to the crossing current

and the number of coils. Common abbreviation is I.No load current: power consumed by the proportional controller when no coil output is available.Threshold current (or polarization): point where increasing input current causes a flow or pressure variation Maximum working current: is the point where input current no longer results into a flow pressure variation.I min - I max: is the minimum and maximum control current fed to the solenoid of the proportional cartridge.Hysteresis: is the measure of the output current difference between increasing and decreasing current in the

solenoid. Example: when current is increasing you need 1200 mA current to produce a 3L/min flow. When current is decreasing,you need 1140 mA current to get the same flow. So there is a 60 mA difference in input current to achieve 3 gpm flow depending on whether current is increasing or decreasing. If I max = 1600mA, and Imin = 350 mA the total input difference is = 1250 mA. Hysteresis=(60/1250)100 = 4.8%.

Pulse with modulation (PWM): amount method used to vary the average current induced in a coil by a squere wave of fixed frequency and variable time ratios.

time ON = time OFF50% Induced current

OFF

ON

80% time on80% Induced current

10% time on10% Induced current

0 1 2 3 4 5 6 7

www.nem-hydraulics.com6.00.001

PROPORTIONAL VALVES

ELECTRIC CARTRIDGES

Page 55: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

116

ELECTRIC CONTROL REQUIREMENTS

NEM spa offers a range of electro proportional controls equipped with 12 and 24 Vcc coils. On going test indicates that a current from 110 to 150 Hz significantly improves the valve performance, as against operation with straight Vcc. The graphs on the side show how the addition of PWM noticeably reduces hysteresis. This feature is available from virtually all standard controls manufacturers at low cost. For valves,hysteresis is represented by a double tracking curve where as the lower and upper track show decreasing and increasing current respectively. These valves are not designed for rapid operation rates. Please consult the factory if relatively fast valve response is required. One way of enhancing operation rates is to add a control function for (I min - I max) adjustment. This function will allow control across the full ran-ge. Again, this feature is widely available on commercial products. Many commercially available controllers also include ramping control.

TYPICAL HYSTERESIS

Vcc current

Pre

ssur

e/Fl

ow

Current Current

Pre

ssur

e/Fl

ow

Vac current

Pre

ssur

e/Fl

ow

Current

l min adjustment l max adjustment

RAMP SLOPE CONTROL

Time (S)

ramp on time ramp off time

Current (A)

www.nem-hydraulics.com6.00.000

PROPORTIONAL VALVES

ELECTRIC CARTRIDGES

Page 56: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

117

CT-473.1 30 250 SAE-10 C430000 6.01.007

CT-523 NC 40 250 SAE-10 C230000 6.01.003

2 WAYS DIRECTIONAL PROPORTIONAL CONTROL VALVES

CT-473.2 30 250 SAE-10 C430000 6.01.007

3 WAYS DIRECTIONAL PROPORTIONAL CONTROL VALVES

4

3

2

1

4

3

2

CT-353 NA 30 350 SAE-10 C330000 6.01.004

2

13

2

3

1

CT-343 NC 30 350 SAE-10 C230000 6.01.001

CT-344 NC 100 350 SAE-12 C240001 6.01.002

CT-353 NC 30 350 SAE-10 C330000 6.01.005 CT-354 NC 70 350 SAE-12 C340000 6.01.006

4 WAYS DIRECTIONAL PROPORTIONAL CONTROL VALVES

1

1

2

1

2

www.nem-hydraulics.com6.00.002

PROPORTIONAL VALVES

ELECTRIC CARTRIDGES

Flowl/min

Pmax bar SIZE CAVITY PAGE

Page 57: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

118

PRESSURE RELIEF VALVES

PRESSURE REDUCING VALVES

CT-052 2 350 SAE-08 C220000 6.01.008

1 2

CT-063 60 350 SAE-10 C230000 6.01.009

1 2

CT-172 4 210 SAE-8 C320000 6.01.010

13

2

FLOW CONTROL VALVES

CT-363 NC 50 250 SAE-10 C330000 6.01.013 CT-364 NC 80 250 SAE-12 C340000 6.01.014

21

1

2

3

CT-333 NC 30 350 SAE-10 C230000 6.01.011 CT-334 NC 50 350 SAE-12 C240000 6.01.012

www.nem-hydraulics.com6.00.003

PROPORTIONAL VALVES

ELECTRIC CARTRIDGES

Flowl/min

Pmax bar SIZE CAVITY PAGE

Page 58: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

119

Ordering code

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 l/min• Max working pressure in 1:2. . . . . . . . . . . . . . .350 bar• Application limits with ∆p max from 1 to 2. . . . . .15 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 150 cc/min• Seals. . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR e PTFE • Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C230000• Max current at 12 Vcc . . . . . . . . . . . . . . . . . . .1800mA• Max current at 24 Vcc . . . . . . . . . . . . . . . . . . . .900mA• PWM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 Hz• Hysteresis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5%• Cartridge thightening torque . . . . . . . . . . . . . . . 40 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 4 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,48 Kg• Coil CT-9800 to be ordered separately

FLOW CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROLS NC

0 3 4 3 1 0 0 1

Flow range

3 5 8

0 1 70100% Q.max 30% Q.max 50% Q.max 80% Q.max

Cartridge SAE 10CT-343 NC

0

8

5

3

0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9(24V) 0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6 1,8(12V)

35

30

25

20

15

10

5

0

8 0

0 5 10 15 20 25 30

12

10

8

6

4

2

0

3 5

1

2

Flow

[l/m

in]

Flow [l/min]

Pres

sure

[ba

r]

Current (Amp.)Graph flow/current with ∆p from 1 to 2 of 7 bar

www.nem-hydraulics.com6.01.001

Pressure drop with energized coil

No emergency Push pin Handknob

Ø38

80,5

32,5

Ø 15,8

1

2

7/8-14 UNF-2A

Hex.27

Page 59: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

120

Ordering code

FLOW CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROLS NC

Cartridge SAE 12

0 3 4 4 1 0 0 1

3 5 8

0 1 70100% Q.max 30% Q.max 50% Q.max 80% Q.max

CT-344 NC

0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1(24V) 0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6 1,8 2(12V)

110

100

90

80

70 60

50

40 30 20

10

0

0 20 40 60 80 100 120 140 160

12

10

8

6

4

2

0

1

2

www.nem-hydraulics.com6.01.002

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 l/min• Max working pressure in 1:2. . . . . . . . . . . . . . .350 bar• Application limits with ∆p max from 1 to 2. . . . . .10 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 150 cc/min• Seals. . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR e PTFE • Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C240001• Max current at 12 Vcc . . . . . . . . . . . . . . . . . . .1800mA• Max current at 24 Vcc . . . . . . . . . . . . . . . . . . . .900mA• PWM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 Hz• Hysteresis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5%• Cartridge thightening torque . . . . . . . . . . . . . . . 50 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 4 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,61 Kg• Coil CT-9800 to be ordered separately

Flow range

No emergency Push pin Handknob

Flow

[l/m

in]

Flow [l/min]

Pres

sure

[ba

r]

Current (Amp.)Graph flow/current with ∆p from 1 to 2 of 5 bar

Pressure drop from 1 to 2

Ø38

9846

Ø 22,181

2

1-1/16"-12 UNF2A

Hex.32

Page 60: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

121

Ordering code

2 WAYS ELECTRIC PROPORTIONAL FLOW CONTROL VALVE.DIRECT ACTED POPPET OPERATED, NC

0 5 2 3 1 0 0 0

5

0100% Q.max 50% Q.max

1 4 75

CT-523 NCCartridge SAE 10

0

5

0,3 0,4 0,5 0,6 0,7 0,8 0,9 (24V)0,6 0,8 1,0 1,2 1,4 1,6 1,8 (12V)

40

35

30

25

20

15

10

5

0

5 0

0 5 10 15 20 25 30 35 40

20

15

10

5

0

1

2

0

5

5 0

www.nem-hydraulics.com6.01.003

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 l/min• Max working pressure in 1:2. . . . . . . . . . . . . . .250 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . .0,25 cc/min• Seals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NBR • Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C230000• Max current at 12 Vcc . . . . . . . . . . . . . . . . . . .1800mA• Max current at 24 Vcc . . . . . . . . . . . . . . . . . . . .900mA• PWM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 Hz• Hysteresis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5%• Cartridge thightening torque . . . . . . . . . . . . . . . 40 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,53 Kg• Coil CT-9800 to be ordered separately

Flow

[l/m

in]

Flow [l/min]

Pres

sure

[ba

r]

Current (Amp.)Graph flow/current with ∆p from 2 to 1

Pressure drop from 2 to 1

Push pin HandknobPush andTwist

Push Button

Flow range

Ø38

8132

,5

Ø 15,81

2

7/8-14 UNF-2A

Hex.27

Page 61: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

122

Ordering code

FLOW CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROLS NC

CT-353 NACartridge SAE 10

2

3

1

0

8

5

3

0,1 0,2 0,3 0,4 0,5 0,6 0,7 (24V)0,2 0,4 0,6 0,8 1,0 1,2 1,4 (12V)

35

30

25

20

15

10

5

0

8 0

0 5 10 15 20 25 30

10

8

6

4

2

0

53

0 3 5 3 4 0 0 1

3 5

030% Q.max 50% Q.max 80% Q.max

8100% Q.max

0 1 7

www.nem-hydraulics.com6.01.004

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 l/min• Max working pressure in 1:2:3. . . . . . . . . . . . . 350 bar• Application limits with ∆p max from 2 to 3. . . . . .15 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 150 cc/min• Seals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NBR • Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C330000• Max current at 12 Vcc . . . . . . . . . . . . . . . . . . .1800mA• Max current at 24 Vcc . . . . . . . . . . . . . . . . . . . .900mA• PWM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 Hz• Hysteresis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5%• Cartridge thightening torque . . . . . . . . . . . . . . . 40 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 4 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,56 Kg• Coil CT-9800 to be ordered separately

Flow range

No emergency Push pin Handknob

Flow

[l/m

in]

Flow [l/min]

Pres

sure

[ba

r]

Current (Amp.)Graph flow/current with ∆p from 2 to 3 of 7 bar

Pressure drop with de-energized coil

Ø38

80,5

46

Ø 15,81

2

Ø 17,40

3

7/8-14 UNF-2A

Hex.27

Page 62: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

123

Ordering code

0 3 5 3 0 0 1

3 5

0100% Q.max 30% Q.max 50% Q.max 80% Q.max

0 1Hydraulic scheme

FLOW CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROLS NC

Cartridge SAE 10

8

Scheme 0 Scheme 1

CT-353 NC

0 1 7

0

8

5

3

35

30

25

20

15

10

5

0

0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 (24V) 0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6 1,8 (12V)

3 5 8 0

0 5 10 15 20 25 30

12

10

8

6

4

2

0

2

3

1

1

2

3

www.nem-hydraulics.com6.01.005

No emergency Push pin HandknobFlow range

Flow

[l/m

in]

Flow [l/min]

Pres

sure

[ba

r]

Current (Amp.)Graph flow/current with ∆p from 3 to 2 of 7 bar

Pressure drop with de-energized coil

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 l/min• Max working pressure in 1:2:3. . . . . . . . . . . . . 350 bar• Application limits with ∆p max from 3 to 2. . . . . .15 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 150 cc/min• Seals. . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR e PTFE • Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C330000• Max current at 12 Vcc . . . . . . . . . . . . . . . . . . .1800mA• Max current at 24 Vcc . . . . . . . . . . . . . . . . . . . .900mA• PWM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 Hz• Hysteresis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5%• Cartridge thightening torque . . . . . . . . . . . . . . . 40 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,56 Kg• Coil CT-9800 to be ordered separately

Ø38

80,5

46

Ø 15,8

1

2Ø 17,40

3

7/8-14 UNF-2A

Hex.27

Page 63: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

124

Ordering code

CT-354 NCCartridge SAE 12

0

7

5

0,3 0,4 0,5 0,6 0,7 0,8 0,9 (24V)0,6 0,8 1,0 1,2 1,4 1,6 1,8 (12V)

60

50

40

30

20

10

0

5

0 10 20 30 40 50 60 70

12

10

8

6

4

2

0

7 0

0 3 5 4 0 0 1

5 7

0100% Q.max 50% Q.max 70% Q.max

0 1 0 1 7

Scheme 0 Scheme 1

2

3

1

1

2

3

Graph 0 with ∆p from 3 to 2 of 11 bar

www.nem-hydraulics.com6.01.006

FLOW CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROLS NC

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 l/min• Max working pressure. . . . . . . . . . . . . . . . . . . .350 bar• Application limits with ∆p max from 3 to 2. . . . . .15 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 250 cc/min• Seals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NBR • Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C340000• Max current at 12 Vcc . . . . . . . . . . . . . . . . . . .1800mA• Max current at 24 Vcc . . . . . . . . . . . . . . . . . . . .900mA• PWM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 Hz• Hysteresis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5%• Cartridge thightening torque . . . . . . . . . . . . . . . 50 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,70 Kg• Coil CT-9800 to be ordered separately

Flow

[l/m

in]

Flow [l/min]

Pres

sure

[ba

r]

Current (Amp.)Graph flow/current with ∆p from 3 to 2 of 7 bar

Pressure drop with energized coil

No emergency Push pin Handknob

Hydraulic scheme

Flow range

Ø38

9869

,5

Ø 22,25

1

2Ø 23,82

3

1-1/16"-12 UNF2A

Hex.32

Page 64: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

125

Ordering code

Scheme 1 Scheme 2

0 4 7 3 0 0 0

3 5

0 3 0100% Q.max 30% Q.max 50% Q.max 80% Q.max

1 2 8

CT-473

4 WAYS DIRECT ACTING ELECTRIC SPOOL VALVE DIRECT ACTING

Cartridge SAE 10

0,3 0,4 0,5 0,6 0,7 0,8 0,9 (24V)0,6 0,8 1,0 1,2 1,4 1,6 1,8 (12V)

35

30

25

20

15

10

5

0 5 10 15 20 25 30

12

10

8

4

2

4

3

2

1

4

3

2

0

8

5

3

3 5 8 0

1

www.nem-hydraulics.com6.01.007

Ø 15,8

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 l/min• Max working pressure in 2:3:4. . . . . . . . . . . . . 250 bar• Max working pressure in 1. . . . . . . . . . . . . . . . . 20 bar• Application limits with ∆p max from 3 to 4/2 . . . .15 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 100 cc/min• Seals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NBR • Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C430000• Max current at 12 Vcc . . . . . . . . . . . . . . . . . . .1800mA• Max current at 24 Vcc . . . . . . . . . . . . . . . . . . . .900mA• PWM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 Hz• Hysteresis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5%• Cartridge thightening torque . . . . . . . . . . . . . . . 40 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . . .0,9 Kg• Coil CT-9800 to be ordered separately

Flow

[l/m

in]

Flow [l/min]

Pres

sure

[ba

r]

Current (Amp.)

Graph 0 with ∆p of 11 barGraph flow/current with ∆p from 3 to 4/2 of 7 bar

Pressure drop with energized coil from 3 to 4/2

Flow range

Hydraulic scheme

No emergency Safety lever

Ø38

Ø 19

122

62

Ø 17,4

Ø 15,8

1

2

3

4

S2

S1

7/8-14 UNF-2A

Hex.27

Page 65: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

126

Ordering code

PRESSURE RELIEF VALVE DIRECT ACTING PROPORTIONAL ELECTRIC CONTROL

0 0 5 2 0 0 0 0

1 2 3

0 1

CT-052

1 2

0

1

2

3

Pres

sure

[ba

r]

400

350 300 250 200

150

100

50

00 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 (24V) 0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6 1,8 (12V)

0123

0 0,5 1 1,5 2 2,5 3 3,5 4 4,5

Pres

sure

[ba

r]

16

14

12 10 8

6

4

2

0

Cartridge SAE 8

SETTING RANGE

0 ÷ 80Min - Max [bar] 0 ÷ 150 0 ÷ 250 0 ÷ 350

www.nem-hydraulics.com6.01.008

Flow [l/min]

Current (Amp.)

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 l/min• Max working pressure in 1. . . . . . . . . . . . . . . . .350 bar• Max working pressure in 2. . . . . . . . . . . . . . . . . .20 bar• Seals. . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR e PTFE • Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C230000• Max current at 12 Vcc . . . . . . . . . . . . . . . . . . .1800mA• Max current at 24 Vcc . . . . . . . . . . . . . . . . . . . .900mA• PWM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 Hz• Hysteresis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5%• Cartridge thightening torque . . . . . . . . . . . . . . . 30 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 4 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,46 Kg• Coil CT-9800 to be ordered separately

Push pin

3/4”-16 UNF-2A

Ø38

89,1

27

Ø 12,7

1

2

Hex.20

Page 66: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

127

Ordering code

Cartridge SAE 10

0 0 6 3 0 0 0 0

0 1 7

CT-063

1 2

3

2

1

400

350 300 250 200

150

100

50

0 0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 (24V) 0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6 1,8 (12V)

16

14

12 10 8

6

4

2

0 0 10 20 30 40 50 60 70 80 90

21SETTING RANGE

0 ÷ 150 0 ÷ 250

3

0 ÷ 350Min - Max [bar]

www.nem-hydraulics.com6.01.009

No emergency Push pin Handknob

PRESSURE RELIEF VALVE DIRECT ACTING PROPORTIONAL ELECTRIC CONTROL

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 l/min• Max working pressure. . . . . . . . . . . . . . . . . . . .350 bar• Seals. . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR e PTFE • Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C230000• Max current at 12 Vcc . . . . . . . . . . . . . . . . . . .1800mA• Max current at 24 Vcc . . . . . . . . . . . . . . . . . . . .900mA• PWM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 Hz• Hysteresis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5%• Cartridge thightening torque . . . . . . . . . . . . . . . 40 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 4 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . .0,48 Kg• Coil CT-9800 to be ordered separately

Pres

sure

[ba

r]Pr

essu

re [

bar]

Flow [l/min]

Current (Amp.)

81

7/8” - 14 UNF2A

1

2

32,5

Ø 12,7

Ø38

Hex.27

Page 67: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

128

Ordering code

CT-172

PRESSURE REDUCING VALVE PROPORTIONAL ELECTRIC CONTROL

Cartridge SAE 8

13

2

30

25

20 15

10

5

00 0,1 0,2 0,3 0,4 0,5 0,6 (24V) 0,2 0,4 0,6 0,8 1,0 1,2 (12V)

www.nem-hydraulics.com6.01.010

• Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 l/min• Max working pressure in 2. . . . . . . . . . . . . . . . .210 bar• Max working pressure in 1. . . . . . . . . . . . . . . . . .30 bar• Max working pressure in 3. . . . . . . . . . . . . . . . . . .1 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 150 cc/min• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C320000• Max current at 12 Vcc . . . . . . . . . . . . . . . . . . .1200mA• Max current at 24 Vcc . . . . . . . . . . . . . . . . . . . .600mA• PWM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 Hz• Hysteresis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5%• Cartridge thightening torque . . . . . . . . . . . . . . . 30 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . . .0,4 Kg• Coil CT-9400 to be ordered separately

Pres

sure

[ba

r]

Current (Amp.)

0 ÷ 30 bar

0 ÷ 20 bar

64,8

39,5

1,5

1

2

3

CH24

64,8

1,5

39,5

Ø26,5

Ø15,8

3/4”-16 UNF-2A

Ø14,2

1

2

Hex.24

0 4

0 1 7 2 2 0 0

Push button

No emergency

60 SETTING RANGE

0 ÷ 30 0 ÷ 20Min - Max [bar]

1

0Without filter With filter

Page 68: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

129

Ordering code

2 WAYS PROPORTIONAL FLOW CONTROL VALVE

Cartridge SAE 10CT-333 NC

0 3 3 3 1 0 0 0 0

0 6

1 2

• Max flow range . . . . . . . . . . . . . . . . . . . . . . . . .30 l/min• Max working pressure. . . . . . . . . . . . . . . . . . . . 350 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 150 cc/min• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C 230000• Cartridge thightening torque. . . . . . . . . . . . . . . . .40 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . . . 0,3 Kg• PWM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120 Hz• Hysteresis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5%• Max current at 24 Vcc . . . . . . . . . . . . . . . . . . . . . . 0,9 A• Max current at 12 Vcc. . . . . . . . . . . . . . . . . . . . . . 1,8 A• Coil CT-9800 to be ordered separately

0 50 100 150 200 250 300 350

30

25

20

15

10

5

0

www.nem-hydraulics.com6.01.011

MANUAL OVERRIDE

Note:- (NC) Normally closed in the energized position

Pres

sure

[ba

r]

Flow [l/min]

Unscrew typeNo emergency

1

2

121,

5 (m

ax 1

27)

89,5

(max

95)

7/8-14 UNF-2A

80,5

112,

5

5

32

Ø15,8

1

2

Hex.27

Page 69: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

130

Ordering code

2 WAYS PROPORTIONAL FLOW CONTROL VALVE

Cartridge SAE 12CT-334 NC

1 2

0 3 3 4 1 0 0 0 0

0 6

0 50 100 150 200 250 300 350

60 55 50 45 40 35 30

25 20 15 10 5 0

Pressure [bar]

Flow

[l/m

in]

www.nem-hydraulics.com6.01.012

MANUAL OVERRIDE

Note:- (NC) Normally closed in the energized position

• Max flow range . . . . . . . . . . . . . . . . . . . . . . . . .50 l/min• Max working pressure. . . . . . . . . . . . . . . . . . . . 350 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 150 cc/min• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C240000• Cartridge thightening torque. . . . . . . . . . . . . . . . .50 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . . . 0,8 Kg• PWM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120 Hz• Hysteresis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5%• Max current at 24 Vcc . . . . . . . . . . . . . . . . . . . . 900mA• Max current at 12 Vcc. . . . . . . . . . . . . . . . . . . 1800mA• Coil CT-9800 to be ordered separately

Unscrew typeNo emergency

47,5

154

106,

5

1-1/16”-12 UNF-2A

97,5

154

3

Ø22,15

1

2

Hex.32

Page 70: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

131

Ordering code

Cartridge SAE 10

0 3 6 3 1 0 0 1

0 5

0 6

CT-363 NC

1

2

3

0

5

Current (Amp.)

0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 (24V) 0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6 1,8 (12V)

Flow

[l/m

in]

35 30

25

20

15

10

5

30

25

20

15

10

5

0

P2-P3 [bar]-350 -300 -250 -200 -150 -100 -50 0 50 100 150 200 250 300 350

Flow

[l/m

in]

www.nem-hydraulics.com6.01.013

Unscrew typeNo emergency

Flow range

3 WAYS PROPORTIONAL FLOW CONTROL VALVE

• Max working flow in 1 . . . . . . . . . . . . . . . . . . . .50 l/min• Max working pressure in 1:2:3 . . . . . . . . . . . . . 350 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 150 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C330000• Cartridge thightening torque. . . . . . . . . . . . . . . . .40 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . . 0,56 Kg• PWM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120 Hz• Hysteresis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5%• Max current at 24 Vcc . . . . . . . . . . . . . . . . . . . . 900mA• Max current at 12 Vcc. . . . . . . . . . . . . . . . . . . 1800mA• Coil CT-9800 to be ordered separately

Port 2 under pressure Port 3 under pressure

30 l/min 15 l/min

2

3

Ø38

80,5

4680

,5

7/8” - 14 UNF2A

1

2

46

Ø 15,8

Ø38

Ø 17,40

Hex.27

Page 71: ELECTRIC CARTRIDGES VALVES ON/OFF - Hydro-Material · 09.7 62 DIRECTIONAL VALVES ELECTRIC CARTRIDGES ON/OFF ELECTRIC CARTRIDGES VALVES ON/OFF

09.7

132

Ordering code

Cartridge SAE 12

0 3 6 4 1 0 0 1

0 6

CT-364 NC

1

2

3

0

5

Current (Amp.)

0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 (24V) 0,2 0,4 0,6 0,8 1,0 1,2 1,4 1,6 1,8 (12V)

Flow

[l/m

in]

70 60

50

40

30

20

10

0

50SETTING RANGE

FLOW RANGE

P2-P3 [bar]-350 -300 -250 -200 -150 -100 -50 0 50 100 150 200 250 300 350

60 55 50 45 40 35 30

25 20 15 10 5 0

Flow

Ran

ge [

l/min

]

www.nem-hydraulics.com6.01.014

3 WAYS PROPORTIONAL FLOW CONTROL VALVE

• Max flow range in 1 . . . . . . . . . . . . . . . . . . . . . 80 l/min• Max working pressure in 1:2:3 . . . . . . . . . . . . . 350 bar• Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . 150 cc/min• Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NBR• Cavity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C340000• Cartridge thightening torque. . . . . . . . . . . . . . . . .50 Nm• Ring nut thightening torque . . . . . . . . . . . . . . . . . 5 Nm• Weight (with coil). . . . . . . . . . . . . . . . . . . . . . . . . 0,7 Kg• PWM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120 Hz• Hysteresis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5%• Max current at 24 Vcc . . . . . . . . . . . . . . . . . . . . 900mA• Max current at 12 Vcc. . . . . . . . . . . . . . . . . . . 1800mA• Coil CT-9800 to be ordered separately

Unscrew typeNo emergency

Port 2 under pressurePort 3 under pressure

60 l/min

35 l/min

2

1-1/16”-12 UNF-2A

Ø38

9869

,5

Ø 22,25

1

2Ø 23,82

3

Hex.32