www.tridonic.com 1Subject to change without notice.
Data sheet 02/13-FD012-6
FL ballastsElectronic dimming
Product description
•Processor-controlledballastwithyIIinside
•HighestpossibleenergyclassCELMAEEI=A1BAT1
•Noise-freeprecisecontrolviaDALIor
DSIsignal,switchDIMorcorridorFUNCTION
•Nominallifeupto100,000h(atta50°C
withafailureratemax.0.2%per1,000h)
•Multi-lampmanagement
•OEM-specificreservedmemoryareas
•5-yearguarantee
Interfaces
•DALI
•DSI
•switchDIM(withmemoryfunction+selectabledimmingrate)
•corridorFUNCTION(3preprogrammedprofiles)
• IntegratedSMARTinterfaceforfunctionwith
SMARTSensor5D19fandcorridorFUNCTIONplugs
Functions
• IntelligentTemperatureGuard(overtemperatureprotection)
• IntelligentVoltageGuard(overvoltageindication
andundervoltageshutdown)
•Optimumfilamentheatinginanydimmersetting
•Disconnectionoffilamentheatingfromadimminglevelofapprox.
90%formaximumenergyefficiency(SMART-Heatingconcept)
•corridorFUNCTIONwithambientlightcontrol
•AutomaticallytriggeredemergencylightingvalueinDCmode,15%
•ForemergencylightingsystemsasperEN50172
•Automaticstartafterreplacementofdefectivelamps
•Automaticshutdownifthelampisfaulty
ÈStandards,page3
Wiring diagrams and installation examples,page8
PCA T8 ECO lp Y II, 18 – 58 WECOT8
T8
6
Ø4,1
LD
214,
130
side fixing feature
Technical dataMainsvoltagerange 220–240V
ACvoltagerange 198–264V
DCvoltagerange 176–280V(lampstart≥198VDC)
Mainsfrequency 0/50/60Hz
Overvoltageprotection 320VAC,1h
Typ.powerinputonstandby <0.2W
Protectivehotrestart 0.5sforAC/0.2sforDC
Dimmingrange 1–100%
Lampstartpossiblefrom 1%
Operatingfrequency ~40–130kHz
Typeofprotection IP20
Ordering data
Type Article number Packaging,carton
Packaging,pallet
Weightperpcs.
For luminaires with 1 lamp
PCA 1x18 T8 ECO lp Y II 22185240 10pc./pcs. 760pc./pcs. 0.231kg
PCA 1x36 T8 ECO lp Y II 28000035 10pc./pcs. 760pc./pcs. 0.222kg
PCA 1x58 T8 ECO lp Y II 28000037 10pc./pcs. 760pc./pcs. 0.234kg
For luminaires with 2 lamps
PCA 2x18 T8 ECO lp Y II 22185243 10pc./pcs. 760pc./pcs. 0.256kg
PCA 2x36 T8 ECO lp Y II 28000039 10pc./pcs. 760pc./pcs. 0.256kg
PCA 2x58 T8 ECO lp Y II 28000041 10pc./pcs. 640pc./pcs. 0.330kg
www.tridonic.com 2Subject to change without notice.
Data sheet 02/13-FD012-6
FL ballastsElectronic dimming
Specific technical dataLampwattage
Lamptype
Type Articlenumber
DimensionsLxWxH
HolespacingD
Lamppower2
Circuitpower2
EEI Currentat50Hz230V2
λat50Hz230V
tcpointmax.
Ambienttemperatureta3
For luminaires with 1 lamp1x18W T8 PCA 1x18 T8 ECO lp Y II 22185240 360x30x21mm 350mm 16W 18.5W A1BAT 0.08A 0.96 80°C -25...70°C
1x36W T8 PCA 1x36 T8 ECO lp Y II 28000035 360x30x21mm 350mm 32W 35.0W A1BAT 0.16A 0.98 85°C -25...70°C
1x58W T8 PCA 1x58 T8 ECO lp Y II 28000037 360x30x21mm 350mm 50W 54.0W A1BAT 0.24A 0.98 85°C -25...70°C
For luminaires with 2 lamps2x18W T8 PCA 2x18 T8 ECO lp Y II 22185243 360x30x21mm 350mm 32W 37.5W A1BAT 0.16A 0.98 75°C -25...60°C
2x36W T8 PCA 2x36 T8 ECO lp Y II 28000039 360x30x21mm 350mm 64W 70.0W A1BAT 0.31A 0.97 80°C -25...60°C
2x58W T8 PCA 2x58 T8 ECO lp Y II 28000041 425x30x21mm 415mm 100W 107.5W A1BAT 0.48A 0.99 80°C -25...55°C1 AccordingtotheEUdirectivesonecodesignrequirements(EC)No.245/2009and(EC)No.347/2010.2 Validat100%dimminglevel.3+10°Ctotamax:unrestricteddimming.-25°Cto+10°C:unrestricteddimmingfrom100%to30%.-25°Cto+10°C,dimmingbelow30%:malfunctionpossiblebutnodamagetoECG.ThisappliestoACandDCoperation.
www.tridonic.com 3Subject to change without notice.
Data sheet 02/13-FD012-6
FL ballastsElectronic dimming
TheballastlumenfactorforACoperation(AC-BLF)doesnotalterfromUn=198VACtoUn=254VAC.TheballastlumenfactorforDCoperation(DC-BLF)onthebasisofanautomaticpowerreductionoftheballasts(defaultvalueis15%)willbesmallerthanAC.ItdoesnotalterintheDCoperatingrange(198–264VDC).
StandardsEN55015EN60929EN61000-3-2EN61347-2-3EN61547SuitableforemergencyinstallationsaccordingtoEN50172CISPR15CISPR22IEC60929IEC61000-3-2IEC61347-2-3IEC61547IEC62386(accordingtoDAListandardV1)
Lamp starting characteristicsWarmstartStartingtime0.5swithACStartingtime0.2swithDCStartatanydimminglevel
AC operationMainsvoltage220–240V50/60Hz198–264V50/60Hzincludingsafetytolerance(±10%)198–254V50/60Hzincludingperformancetolerance(+6%/-8%)
DC operation220–240V0Hz198–254V0Hzcertainlampstart176–280V0HzoperatingrangeUseinemergencylightinginstallationsaccordingtoEN50172orforemergencyluminairesaccordingtoEN61347-2-3appendixJ.
MainscurrentfordefectiveormissinglampsatDCoperation<35mA.
Light output level in DC operationDefaultvalueis15%
Emergency unitsThe“PCAT8ECOlpy II”ballastsarecompatiblewithallemergencyunitsfromTridonic.Seethetableinthedatasheet.Alsoall“5-pole”emergencyunitscanbeused.Whenusedwithotheremergencyunitstestsarenecessary.
Temperature rangeUnlimiteddimmingrangefrom10°Ctotamax.-25°Cto10°C:dimmingoperationfrom100%to30%.Ifdimmlevelgoesbelow30%malfunctionpossible,butnoelectronicballastdamage.ThisappliestoACandDCoperation.
Mains currents in DC operation (at 15 % light output)
TypeLamptype Wattage Mainscurrentat
Un=220VDCMainscurrentatUn=275VDC
PCA 1x18 T8 ECO lp Y II T8 1x18W 0.04A 0.03APCA 1x36 T8 ECO lp Y II T8 1x36W 0.06A 0.05APCA 1x58 T8 ECO lp Y II T8 1x58W 0.08A 0.07APCA 2x18 T8 ECO lp Y II T8 2x18W 0.07A 0.06APCA 2x36 T8 ECO lp YII T8 2x36W 0.11A 0.09APCA 2x58 T8 ECO lp Y II T8 2x58W 0.16A 0.13A
Ballast lumen factor AC operation (AC-BLF) EN 60929 8.1
Type Lamptype Wattage AC-BLFatU=230VAC
PCA 1x18 T8 ECO lp Y II T8 1x18W 0.99PCA 1x36 T8 ECO lp Y II T8 1x36W 1.00PCA 1x58 T8 ECO lp Y II T8 1x58W 1.00PCA 2x18 T8 ECO lp Y II T8 2x18W 0.99PCA 2x36 T8 ECO lp YII T8 2x36W 1.00PCA 2x58 T8 ECO lp Y II T8 2x58W 1.00
www.tridonic.com 4Subject to change without notice.
Data sheet 02/13-FD012-6
FL ballastsElectronic dimming
DSI PCA T8 ECO lpY II
switchDIM PCA T8 ECO lpY II
DALI PCA T8 ECO lpY II
234
67 D2
D1DSI
234
67L
ND2D1
234
67 DA
DADALI
DimmingDimmingcurveisadaptedtotheeyesensitiveness.Dimmingrange1%to100%Digitalcontrolwith:•DSIsignal:8bitManchesterCodeSpeed1%to100%in1.4s
•DALIsignal:16bitManchesterCodeMaximumspeed1%to100%in550ms(adjustablebetween100msand90s)Programmableparameter:MinimumdimminglevelMaximumdimminglevelDefaultminimum=1%Defaultmaximum=100%
Control input (DA/D1, DA/D2)DigitalDALI/DSIsignalorapush-to-makeswitch(switchDIM)oramotiondetector(corridorFUNCTION)canbewiredonthesameterminals(DA/D1andDA/D2).
Digital signal DALI/DSIThecontrolinputisnon-polarandprotectedagainstaccidentalconnectionwithamainsvoltageupto264V.ThecontrolsignalisnotSELV.Controlcablehastobeinstalledinaccordancetotherequirementsoflowvoltageinstallations.Differentfunctionsdependingoneachmodule.
SMART interfaceAnadditionalinterfaceforthedirectconnectionoftheSMART-Sensor5D19f1)orcorridorFUNCTIONplugs.ApplicationandfunctionallityseecorridorFUNCTION usermanual.SMART-Sensor5D19f1)lightsensoroperatingmode:Thesensorregistersactualambientlightandmain-tainstheindividuallydefinedconstantluxlevel.AftereverymainsresettheSMARTinterfaceauto-maticallychecksforaninstalledsensor.WiththesensorinstalledthePCAT8ECOlpyIIautomaticallyrunsintheconstantluxlevelmode.ON/OFFswitchviamains,switchDIMorDSIsignal.DSIsignal=0switchesoff,DSIsignal≥1switcheson.WithswitchDIMsignalsitispossibletochangethecontrolledlightleveltemporarily.TemporarilymeansthatafteraswitchingcycleOFF/ONcommandtheballastwillstartatthepresetvaluedeterminedbytheSMART-Sensor5D19f.Theinstalla-tionofthetwowirebusisaccordingtotheappropriatelowvoltageregulations.
switchDIMIntegratedswitchDIMfunctionallowsadirectconnectionofapushtomakeswitchfordimmingandswitching.Briefpush(<0.6s)switchesballastONandOFF.Theballastsswitch-ONatlightlevelsetatswitch-OFF.AfterswitchONthelastsettetdimminglevelwillbeactivatedagain.Whenthepushtomakeswitchisheld,PCAballastsaredimmed.AfterrepushthePCAisdimmedintheoppositedirection.TheswitchDIMfadetimeissetto3sfrommin.tomax.inthefactorysettings.Witha20spushtothepushtomakeswitchthisfadetimecanbechangedto6s.InthisinstancetheswitchDIMapplicationwillbesynchronizedto50%lightlevelafter10sandafter20sthelightlevelrisesto100%withthenewfadetime.
225
255
DALI200
175
150
125
100
75
50
25
0
1009080706050403020100
digitaldimmingvalue
relativelightinglevelin%
100
90
80
70
60
50
40
30
20
10
0
100 90 80 70 60 50 40 30 20 15 10 5 4 3 2 1
Energy saving PCA T8 ECO lp Y II
mainspowerin%
dimminglevelin%
Dimmingcharacteristicsasseenbythehumaneye
DSI
Dimming characteristics PCA T8 ECO lp Y II
corridorFUNCTIONToactivatethecorridorFUNCTIONavoltageof230VsimplyhastobeappliedforfiveminutesatswitchDIMconnection.TheunitwillthenswitchautomaticallytothecorridorFUNCTION.Note:IfthecorridorFUNCTIONiswronglyactivatedinaswitchDIMsystem(forexampleaswitchisusedinsteadofpushbutton),thereistheoptionofinstallingapushbuttonanddeactivatingthecorridorFUNCTIONmodebyfiveshortpushesofthebuttonwithinthreeseconds.ThecorridorFUNCTIONofferstheaddedbenefitofasecondandthirdpreprogrammedprofile,whichcanbeactivatedbythecorridorFUNCTIONplugs.ItisalsopossibletocombinethecorridorFUNCTIONwiththeSMART-Sensor5D19flightsensor.ApplicationandfunctionallityofprofilesseeusermanualofthecorridorFUNCTION.
1) SMART-Sensor5D19f:articlenumber86459169
Ateverysynchronizsation(10skeystroke)thedevicewillresetto3s(factorysetting)IninstallationswithPCAswithdifferentdimminglevelsoroppositedimmingdirections(e.g.afterasystemextension),allPCAscanbesynchronizedto50%dimminglevelbya10spush.Useofpushtomakeswitchwithindicatorlampisnotpermitted.switchDIMandcorridorFUNCTIONareverysimpletoolsforcontrollingballastswithconventionalmomentary-actionswitchesormotionsensors.Toensurecorrectoperationasinusoidalmainsvoltagewithafrequencyof50Hzor60Hzisrequiredatthecontrolinput.Specialattentionmustbepaidtoachievingclearzerocrossings.SeriousmainsfaultsmayimpairtheoperationofswitchDIMandcorridorFUNCTION.
corridorFUNCTION PCA T8 ECO lpY II
234
67L
ND2D1
www.tridonic.com 5Subject to change without notice.
Data sheet 02/13-FD012-6
FL ballastsElectronic dimming
Continuousoperation:tocalculatetheprotectivesafteyswitchseemaincurrent,page2
Intelligent Temperature GuardTheintelligenttemperatureguardprotectsthePCAT8ECOlpyIIfromthermaloverheatingbyreducingtheoutputpowerorswitchingoffincaseofoperationabovethethermallimitsoftheluminaireorballast.Dependingontheluminairedesign,theITGoperatesatabout5to10°Cabovetctemperature.
Intelligent Voltage GuardIntelligentVoltageGuardisthenameoftheelectronicmonitorfromTridonic.ThisinnovativefeatureofthePCAfamilyofcontrolgearfromTridonicimmediatelyshowsifthemainsvoltagerisesabovecertainthresh-olds.Measurescanthenbetakenquicklytopreventdamagetothecontrolgear.
Loading of automatic circuit breakers (Limitation via inrush current)Automaticcircuitbreakertype C10 C13 C16 C20 B10 B13 B16 B20 Inrushcurrent(1.5mm2) Inrushcurrent(2.5mm2)
InstallationØ 1.5mm2 1.5mm2 1.5mm2 2.5mm2 1.5mm2 1.5mm2 1.5mm2 2.5mm2 Imax time Imax time
PCA 1x18 T8 ECO lp YII 50 82 161 201 25 41 120 107 19.3A 166µs 19.7A 165µs
PCA 1x36 T8 ECO lp YII 36 54 80 92 18 27 40 46 19.2A 189µs 19.6A 187µs
PCA 1x58 T8 ECO lp YII 22 34 46 54 11 17 23 27 24.7A 224µs 24.4A 227µs
PCA 2x18 T8 ECO lp YII 34 50 76 86 17 25 38 43 20.3A 204µs 23.3A 184µs
PCA 2x36 T8 ECO lp YII 22 32 42 52 11 16 22 26 26.4A 210µs 27.2A 207µs
PCA 2x58 T8 ECO lp YII 16 22 28 34 8 11 15 17 28.6A 290µs 29.1A 289µs
• Ifthemainsvoltagerisesaboveapprox.318Vrms(voltagedependsontheballasttype),thelampstartsflashingonandoff.
•Toavoidadamageofthedevicethemainssupplyhastobeswitchedoffatthissignal.
Humidity: 5%uptomax.85%, notcondensed (max.56days/yearat85%)
Storagetemperature:-40°Cuptomax.+80°C
Thedeviceshavetobewithinthespecifiedtemperaturerange(ta)beforetheycanbeoperated.
Harmonic distortion in the mains supply (at 230 V / 50 Hz)Type Lamptype Wattage THD 3 5 7 9 11
PCA 1x18 T8 ECO lp Y II T8 1x18W 9 5 2 1 1 1PCA 1x36 T8 ECO lp Y II T8 1x36W 10 8 2 2 2 2PCA 1x58 T8 ECO lp Y II T8 1x58W 6 5 2 2 1 1PCA 2x18 T8 ECO lp Y II T8 2x18W 8 5 2 1 1 1PCA 2x36 T8 ECO lp YII T8 2x36W 7 5 1 1 2 2PCA 2x58 T8 ECO lp Y II T8 2x58W 6 5 1 1 1 1
Operating voltage
Type Lamptype Wattage UoutPCA 1x18 T8 ECO lp Y II T8 1x18W 430VPCA 1x36 T8 ECO lp Y II T8 1x36W 430VPCA 1x58 T8 ECO lp Y II T8 1x58W 430VPCA 2x18 T8 ECO lp Y II T8 2x18W 430VPCA 2x36 T8 ECO lp YII T8 2x36W 430VPCA 2x58 T8 ECO lp YII T8 2x58W 430V
Expected lifetimeType Lamptype Wattage ta = 40 °C ta = 50 °C ta = 60 °C
PCA 1x18 T8 ECO lp Y II T8 1x18Wtc 50°C 60°C 70°CLifetime ≥100,000h ≥100,000h ≥100,000h
PCA 1x36 T8 ECO lp Y II T8 1x36Wtc 55°C 65°C 75°CLifetime ≥100,000h ≥100,000h ≥100,000h
PCA 1x58 T8 ECO lp Y II T8 1x58Wtc 55°C 65°C 75°CLifetime ≥100,000h ≥100,000h ≥100,000h
PCA 2x18 T8 ECO lp Y II T8 2x18Wtc 60°C 70°C 80°CLifetime ≥100,000h ≥100,000h ≥50,000h
PCA 2x36 T8 ECO lp YII T8 2x36Wtc 65°C 70°C 80°C
Lifetime ≥100,000h ≥100,000h ≥50,000h
PCA 2x58 T8 ECO lp YII T8 2x58Wtc 65°C 75°C 80°C
Lifetime ≥100,000h ≥50,000h ≥50,000hx=notpermitted
www.tridonic.com 6Subject to change without notice.
Data sheet 02/13-FD012-6
FL ballastsElectronic dimming
RFI•Connectiontothelampsofthehotleadsmustbekeptasshortaspossible
•Mainsleadsshouldbekeptapartfromlampleads(ideally5–10cmdistance)
•Donotrunmainsleadsadjacenttotheelectronicballast
•Twistthelampleads•Keepthedistanceoflampleadsfromthemetalworkaslargeaspossible
•Mainswiringtobetwistedwhenthroughwiring•Keepthemainsleadsinsidetheluminaireasshortaspossible
General adviseElectronicballastsarevirtuallynoisefree.Magneticfieldsgeneratedduringtheignitioncyclecancausesomebackgroundnoisebutonlyforafewmilliseconds.
For further technical information please visit www.tridonic.com
PCA T8 ECO lp Y II 1x14–80 W PCA T8 ECO lp Y II 2x14–80 W
* * control signal
* leads 15, 16: keep wires short, max. 1.0 m leads 13, 14: max. 2.0 m; ballast must be earthed* * digital signal (DSI), DALI or switchDIM
DA/D2
DA/D1
234
67
141516
13
* * control signal
* leads 10, 11, 15, 16: keep wires short, max. 1.0 m leads 12, 13, 14: max. 2.0 m; ballast must be earthed* * digital signal (DSI), DALI or switchDIM
DA/D2
DA/D1
234
67
141516
13121110
DimmableballastsfromTridonichavetobeearthed.
Operation on DC voltageOurballastsareconstruedtooperateDCvoltageandpulsedDCvoltage.TooperateballastswithpulsedDCvoltagethepolarityisabsolutemandatory.
234
67
D1
D2
+–
Isolation and electric strength testing of luminairesElectronicdevicescanbedamagedbyhighvoltage.Thishastobeconsideredduringtheroutinetestingoftheluminairesinproduction.
AccordingtoIEC60598-1AnnexQ(informativeonly!)orENEC303-AnnexA,eachluminaireshouldbesub-mittedtoanisolationtestwith500VDCfor1second.Thistestvoltageshouldbeconnectedbetweentheinterconnectedphaseandneutralterminalsandtheearthterminal.Theisolationresistancemustbeatleast2MΩ.
Asanalternative,IEC60598-1AnnexQdescribesatestoftheelectricalstrengthwith1500VAC(or1.414x1500VDC).Toavoiddamagetotheelectronicdevicesthistestmustnotbeconducted.
Wiring adviceTheleadlengthisdependentonthecapacitanceofthecable.
Installation instructions
Wiring type and cross sectionThewiringcanbesolidcablewithacrosssectionof0.5to0.75mm²forpushterminaland0.5mm²forIDCterminal.Forthepush-wireconnectionyouhavetostriptheinsulation(8–9mm).
Loosenwirethroughtwistingandpulling
Withstandardsolidwire0.5/0.75mm²thecapacitanceoftheleadis30–80pF/m.Thisvalueisinfluencedbythewaythewiringismade.Lampconnectionshouldbemadewithsymmetricalwiring.Hotleads(10,11,15,16)andcoldleads(12,13,14)shouldbeseparatedasmuchaspossible.Whenusingtwoormoredimmableballastsinoneluminairewithseparatedimmingcontrols,thelampleadsmustbekeptseparate.
Sensor wiresSensorwiresmustberoutedseparatelyfromthelampwiresandmainscablesotherwisethelightingcontrolsystemmaymalfunction.Ifseparateroutingisnotpossible(forreasonsofspace)shieldedlampwiresandmainscablesmustbeused.
DimmableballastsfromTridonichavetobeearthed.
Ballast Terminal Maximum capacitance allowed
Type Cold Hot Cold Hot
PCA 1xx T8 ECO lp Y II 13,14 15,16 200pF 100pF
PCA 2xx T8 ECO lp Y II 12,13,14 10,11,15,16 200pF 100pF
8–9mm
wirepreparation:0.5–0.75mm²