ElastQ Imaging | Liver Quick Guide Confidence Map & Threshold · Ultrasound The color-coded...

2
Quick Guide Ultrasound The color-coded Confidence Map reflects a value for each pixel, providing an indication of quality across the stiffness value map. This assists the user in obtaining measurements from the areas with the highest shear wave quality. Every pixel in the ROI is assigned a confidence value from 0 to 100 and a corresponding color between red and green. Low values (red) indicate that the stiffness value for a given pixel is less reliable. High values (green) indicate that the stiffness value for a given pixel is more reliable. Several factors can lower the confidence value: tissue areas with blood flow (vessels), low echogenicity (such as the gallbladder), low shear wave strength (as when scanning deep in the Technically Difficult Patient), or with large tissue motion (as with no breath pause). The confidence map reflects shear waves strengths but may not detect ultrasound artifacts such as reverberation and rib shadowing artifacts. Use of the confidence map can enhance the exam if the scan technique is optimal, but it cannot overcome suboptimal scanning technique. Examples of suboptimal scanning technique are placing the ROI and taking measurements within 1.5 cm of Glisson’s capsule (producing a reverberation artifact) or placing the ROI on the edge of a rib or lung shadow. We recommend to turn on the confidence map to verify that the calipers that are placed on the stiffness map are in areas with high confidence (green on the confidence map). Confidence Map Confidence Threshold The Confidence Threshold sets those areas of a stiffness/velocity image with lower confidence as transparent. For example, setting the confidence threshold to 60% will set areas of a stiffness/velocity image with a confidence value of less than 60% as transparent. The transparent areas will not be measured. Changing the confidence threshold will not change the confidence map. A Confidence Threshold of 60% is recommended. Press the Confidence Map button to enable/ disable the Confidence Map function. Turn this rotary to adjust the Confidence Threshold. Confidence Map ElastQ image mapping tissue stiffness Turn this rotary for additional color enhancements. EPIQ Elite Release 4.0 ElastQ Imaging | Liver Confidence Map & Threshold

Transcript of ElastQ Imaging | Liver Quick Guide Confidence Map & Threshold · Ultrasound The color-coded...

Page 1: ElastQ Imaging | Liver Quick Guide Confidence Map & Threshold · Ultrasound The color-coded Confidence Map reflects a value for each pixel, providing an indication of quality across

Quick Guide

Ultrasound

The color-coded Confidence Map reflects a value for each pixel, providing an indication of quality across the stiffness value map. This assists the user in obtaining measurements from the areas with the highest shear wave quality.

Every pixel in the ROI is assigned a confidence value from 0 to 100 and a corresponding color between red and green. Low values (red) indicate that the stiffness value for a given pixel is less reliable. High values (green) indicate that the stiffness value for a given pixel is more reliable.

Several factors can lower the confidence value: tissue areas with blood flow (vessels), low echogenicity (such as the gallbladder), low shear wave strength (as when scanning deep in the Technically Difficult Patient), or with large tissue motion (as with no breath pause). The confidence map reflects shear waves strengths but may not detect ultrasound artifacts such as reverberation and rib shadowing artifacts.

Use of the confidence map can enhance the exam if the scan technique is optimal, but it cannot overcome suboptimal scanning technique. Examples of suboptimal scanning technique are placing the ROI and taking measurements within 1.5 cm of Glisson’s capsule (producing a reverberation artifact) or placing the ROI on the edge of a rib or lung shadow.

We recommend to turn on the confidence map to verify that the calipers that are placed on the stiffness map are in areas with high confidence (green on the confidence map).

Confidence Map

Confidence Threshold

The Confidence Threshold sets those areas of a stiffness/velocity image with lower confidence as transparent. For example, setting the confidence threshold to 60% will set areas of a stiffness/velocity image with a confidence value of less than 60% as transparent. The transparent areas will not be measured. Changing the confidence threshold will not change the confidence map.

A Confidence Threshold of 60% is recommended.

Press the Confidence Map button to enable/disable the Confidence

Map function.

Turn this rotary to

adjust the Confidence Threshold.

Confidence Map ElastQ image mapping tissue stiffness

Turn this rotary for additional

color enhancements.

EPIQ Elite Release 4.0

ElastQ Imaging | LiverConfidence Map & Threshold

Page 2: ElastQ Imaging | Liver Quick Guide Confidence Map & Threshold · Ultrasound The color-coded Confidence Map reflects a value for each pixel, providing an indication of quality across

Confidence Map & ThresholdConfidence Threshold

© 2019 Koninklijke Philips N.V. All rights are reserved.

Philips reserves the right to make changes in

specifications and/or to discontinue any product at any

time without notice or obligation and will not be liable

for any consequences resulting from the use of this

publication. Trademarks are the property of Koninklijke

Philips N.V. or their respective owners.

philips.com

Printed in The Netherlands. 4522 991 44651 * JAN 2019

60% 75%25%

Please consult the user manual for further information.