22
Approvals and Standards Required for UK WRAS (water regulations advisory scheme) Compliance with Building regulations Part G3 Compliance with Building regulations Part F Compliance with Building regulations Part L Listing in Part L Appendix Q Compliance with Building regulations Part P EMC LVD CE Eksempel på forskellige nødvendige godkendelser og standarder (UK)

Transcript of Eksempel på forskellige nødvendige godkendelser og ... EN 14324: 2004 Brazing - Guidance on the...

Approvals and Standards Required for UK

WRAS (water regulations advisory scheme)

Compliance with Building regulations Part G3

Compliance with Building regulations Part F

Compliance with Building regulations Part L

Listing in Part L Appendix Q

Compliance with Building regulations Part P

EMC

LVD

CE

Eksempel på forskellige nødvendige godkendelser og

standarder (UK)

Heat pump standards UK

BS 1306:1975 Specification for copper and copper alloy pressure piping systems

BS 1710:1984 Specification for identification of pipelines and services

BS 7074-1: 1989Application, selection and instillation of expansion vessels and ancillary equipment for sealed water systems. Code of practice for

domestic heating and hot water supply

BS 7593: 2006 Code of practice for treatment of water in domestic hot water central heating systems

BS 7671:2008 Requirements for electrical installation. IEE Wiring regulations (17th edition)

BS EN 1254-1:1998 Copper and copper alloys. Plumbing fittings. Fittings with ends for capillary soldering or capillary brazing to copper tubes

BS EN 1254-2:1998 Copper and copper alloys. Plumbing fittings. Fittings with compression ends for use with copper tubes

BS EN 1254-3:1998 Copper and copper alloys. Plumbing fittings. Fittings with compression ends for use with plastics pipes

BS EN 1254-4:1998 Copper and copper alloys. Plumbing fittings. Fittings combining other end connections with capillary or compression ends

BS EN 1254-5:1998 Copper and copper alloys. Plumbing fittings. Fittings with short ends for capillary brazing to copper tubes

BS EN 12828:2003 Heating systems in buildings. Design for water-based heating systems

BS EN 14324: 2004 Brazing - Guidance on the application of brazed joints

BS EN 14511-1:2007 Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling Part

1: Terms and definitions

BS EN 14511-2:2007Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling Part

2: Test conditions

BS EN 14511-3:2007Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling Part

3: Test methods

Eksempel på forskellige normer og standarder

BS EN 14511-4:2004Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling

Part 4: Requirements

BS EN 15332:2007 Heating boilers - Energetic assessment of hot water storage tanks

BS EN 378-1: 2008Refrigerating systems and heat pumps - Safety and environmental requirements - Part 1: Basic requirements, definitions,

classification and selection criteria

BS EN 378-2: 2008Refrigerating systems and heat pumps - Safety and environmental requirements - Part 2: Design, construction, testing,

marking and documentation

BS EN 378-3: 2008Refrigerating systems and heat pumps - Safety and environmental requirements - Part 3: Installation site and personal

protection

BS EN 378-4: 2008Refrigerating systems and heat pumps - Safety and environmental requirements - Part 4: Operation, maintenance, repair and

recovery

BS EN 50366:2003 Household and similar electrical appliances. Electromagnetic fields. Methods for evaluation and measurement

BS EN 55014-1:2006 Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus -- Part 1: Emission

BS EN 55014-2:1997,

CISPR 14-2:1997

Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus -- Part 2: Immunity

- Product family standard

BS EN 60335-

1:2002+A2:2006 Household and similar electrical appliances - Safety -- Part 1: General requirements

BS EN 60335-2-40:2003 Household and similar electrical appliances - Safety -- Part 2-40: Particular requirements for electrical heat pumps, air-

conditioners and dehumidifiers

BS EN 61000-3-2:2006Electromagnetic compatibility (EMC) -- Part 3-2: Limits - Limits for harmonic current emissions (equipment input current <= 16

A per phase)

BS EN 61000-3-3:2008,

IEC 61000-3-3:2008

Electromagnetic compatibility (EMC) -- Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public

low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection

BS EN 62233:2008Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human

exposure

BS EN 12102:2008Air conditioners, heat pumps and dehumidifiers with electrically driven compressors – Measurement of airborne noise –

Determination of the sound power level.

BS EN 13771-1:2003 Compressors and condensing units for refrigeration - Performance testing and test methods - Part 1: Refrigerant compressors

Eksempel på forskellige normer og standarder

BS EN 13771-1:2003 Compressors and condensing units for refrigeration - Performance testing and test methods - Part 1: Refrigerant compressors

BS EN 13771-2:2007 Compressors and condensing units for refrigeration - Performance testing and test methods - Part 2: Condensing units

EN 255-3:1997/AC:1997 Heat pumps for sanitary warm water

BS EN 60204-1:2006 Safety of machinery - Electrical equipment of machines -- Part 1: General requirements

EN 60335-2-

21:2003/A1:2005Household and similar electrical appliances - Safety -- Part 2-21: Particular requirements for storage water heaters

BS EN 61000-3-11:2001Electromagnetic compatibility (EMC) -- Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public

low-voltage supply systems - Equipment with rated current <= 75 A and subject to conditional connection

EN 61000-4-

2:1995/A1:1998Electromagnetic compatibility (EMC) -- Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test

EN 61000-4-4: 1995Electromagnetic compatibility (EMC) -- Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity

test

BS EN ISO 11203:1996Acoustics - Noise emitted by machinery and equipment - Determination of emission sound pressure levels at a work station and

at other specified positions from the sound power level (ISO 11203:1995)

BS EN ISO 3743-2:1997Acoustics - Determination of sound power levels of noise sources using sound pressure - Engineering methods for small,

movable sources in reverberant fields - Part 2: Methods for special reverberation test rooms (ISO 3743-2:1994)

BS EN 61000-4-2:1995 Electromagnetic compatibility (EMC) -- Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test

Eksempel på forskellige normer og standarder

Bedingungen die subentionen zu erhalten:

A) Wärmepumpen sole-wasser oder sole-sole mit kältmittelkreislauf

als erdwärmeträger= COP grösser oder gleich 3,3 bei -5°C

aussentemperatur und einer kondensationsstemperatur von 35°C.(1° Les

pompes à chaleur géothermiques à capteur fluide frigorigène detype sol-sol

ou sol-eau ayant un coefficient de performance supérieurou égal à 3,3 pour

une température d'évaporation de - 5 °C et unetempérature de condensation

de 35 °C)

B) Wärmepumpen wasser-wasser mit wasser-glycol-kreislauf als

erdwärmeträger= COP grösser oder gleich 3,3 bei 0°C. bei ein- und austritt

des kreislaufes und -3°C kondensationsstemperatur,ein- und

austrittstemperatur zwischen 30°C. und 35°C. beim kondensator(2° Les

pompes à chaleur géothermiques de type eau glycolée/eau ayant

uncoefficient de performance supérieur ou égal à 3,3 pour destempératures

d'entrée et de sortie d'eau glycolée de 0° C et - 3 °C àl'évaporateur, et des

températures d'entrée et de sortie d'eau de 30 °Cet 35 °C au condenseur,

selon le référentiel de la norme d'essai14511-2)C)

Eksempel på forskellige definitioner for opnåelse af tilskud

C) Wärmepumpen wasser-wasser geothermie= COP grösser oder gleich 3,3 bei einer austrittstemperatur von 10°C. und 7°C. wassertemperatur beim verdampfer.

und zwischen 30°C. und 35°C. beim kondensator(3° Les pompes à chaleur

géothermiques de type eau/eau ayant uncoefficient de performance supérieur ou

égal à 3,3 pour destempératures d'entrée et de sortie de 10 °C et 7 °C d'eau

àl'évaporateur, et de 30 °C et 35 °C au condenseur, selon le référentielde la norme

d'essai 14511-2)D)

Wärmepumpen luft-wasser= COP grösser oder gleich 3,3 bei 7°C

verdampfertemperatur, ein- und austrittstemperatur zwischen 30°C. und 35°C. beim

kondensator.(4° Les pompes à chaleur air/eau ayant un coefficient de

performancesupérieur ou égal à 3,3 pour une température d'entrée d'air de 7 °C

àl'évaporateur, et des températures d'entrée et de sortie d'eau de 30 °Cet 35 °C au

condenseur, selon le référentiel de la norme d'essai14511-2)

Eksempel på forskellige definitioner for opnåelse af tilskud

Test af ventilationsanlæg med varmepumper

Hvordan griber vi det an i Nilan?

- V/ Udviklingsingeniør Ph.D Lis Jacobsen, Nilan A/S

Formål med testen

Dokumentation for kunder og myndigheder

Ydelse

Funktion

Sikkerhed

Test og dokumentation af ventilationsvarmepumper

COP luft-luft

COP luft-vand

SEL

Kapacitet

Temperaturvirkningsgrad

Relativ COP

Lækage

Testresultater - Ydelse

Test og dokumentation af ventilationsvarmepumper

Comfort

Hygiejne

Støj

Vibration

Afrimning

Testresultater - Funktion

Test og dokumentation af ventilationsvarmepumper

BR10

Passivhaus (Tyskland)

SAP 2005 (England)

DIBt (Tyskland)

Minergie P (Schweiz)

Wohnbauförderung (Østrig)

Specifikke krav til test af ydelse

nationale myndigheder og organisationer

Eksempel Passivhaus teststandard

Måling og beregning af data til PHPP

Lækage: EN 308

Støj: EN 3743-1 and EN 9614-2, (31,5-8000Hz)

Behagelighedskriterie: PHI

Afrimning: PHI

Temperaturvirkningsgrad: DIBt

SEL: PHI

COP L/V L/L: PHI (EN 255)

Kapacitet: PHI

Grænseværdier

Lækage: Max. 3% af middel volumenstrøm

Støj: Lydeffekt overflade Lw(A): Opholdsrum 25 dB(A), Bryggers 30 dB(A)

Behagelighedskriterie: Indblæsningstemperatur minimum 16,5 C ved t_ude = -10 C

Afrimning: Kontinuerlig volumenstrøm ved t_ude = -16 C

Temperaturvirkningsgrad: Minimum 75% (tør)

SEL: Max. 0,45 W/m3h (1620 J/m3)

Filter klasse: Indblæsning F7, udsugning G4

COP L/V L/L: PHPP Klimadaten Standard, Grænseværdi 55 kWh/(m2a)

Kapacitet: Balanceret luftskifte

Strømsvigt Automatisk genstart driftsopsætning

Skabelon – tast overskrift

EN255-3

PHI Prüfverfaren

COP:

EN255-3

1. Tappning

2. Standby

PHI Prüfverfaren

1. Opladning

2. Tapning

Coefficient of Performance COP luft/vand

Test og dokumentation af ventilationsvarmepumper

Passivhaus

ηeff,WRG=(t11-t12+Wel/m*Cp)/(t11-t12)

EN 308

ηt=(t22-t21)/(t11-t21)

Eksempel på forskellige definitioner for

temperaturvirkningsgrad

Test og dokumentation af ventilationsvarmepumper

Hvilken standard?

Opsætning af anlæg: Interne og eksterne modtryk.

Beregning: Totale elforbrug eller elforbrug til

blæsere.

Definition på SEL-værdi?

Test og dokumentation af ventilationsvarmepumperYdelse: EN 14511, EN 14825

Ydelse: EN255-3Ydelse: EN 255-3

Ydelse: EN255-3Ydelse: EN 14511, EN 255-3

Test og dokumentation af ventilationsvarmepumperYdelse: EN 14511, EN 14825, EN 308, EN 255-3

Test og dokumentation af ventilationsvarmepumperTest faciliteter hos Nilan

Test og dokumentation af ventilationsvarmepumperVores erfaringer/anbefalinger

• Det er vanskeligt at få et overblik over hvilke nationale krav der

stilles til dokumentation

• De nationale krav til dokumentation er sjældent identiske

• Definitioner i standarderne omfatter ikke alle anlægstyper

• Kravene til ydelse ændres konstant, hvilket nødvendiggør nye

produkter og ny dokumentation

• Specifikation af anlægstyper er ofte utilstrækkelig dvs. vi

sammenligner æbler og pærer