EFT/B simulator after service and support notice · Taking account of field troubles is possible....

2
1 www.noiseken.com The fast transient / burst simulator you always use is renewed now. For repair maintenance in our company, we discontinue repair support 8 years after delivery according to warranty and 5 years after sales termination. After that, we may decline to repair. We inform you of the following fast transient burst simulator's repair support status, compliant standard and successor product. Standard shift & model Model Repair service and support status successive mode FNS-029series terminated FNS-AX4series FNS-100AXseries terminated FNS-AX4series FNS-100Lseries terminated FNS-AX4series FNS-101AXseries terminated FNS-AX4series FNS-101Lseries terminated FNS-AX4series FNS-103L terminated FNS-AX4series FNS-104Lseries terminated FNS-AX4series FNS-105AX terminated FNS-AX4series FNS-105L terminated FNS-AX4series FNS-AX2 A16 terminated FNS-AX4-A20 FNS-AX2 B50 terminated FNS-AX4-B63 Standard shift & model Model Repair service and support status successive mode FNS-AX2 B50 terminated FNS-AX4-B63 FNS-2002 terminated FNS-AX4-A20 FNS-AX3 A16 terminated FNS-AX4-A20 FNS-AX3 B50 terminated FNS-AX4-B63 FNS-AX3 A16A terminated FNS-AX4-A20 FNS-AX3 B50A terminated FNS-AX4-B63 FNS-AX3 A16B partially terminated FNS-AX4-A20 FNS-AX3 B50B partially terminated FNS-AX4-B63 FNS-AX3 A16C in service FNS-AX4-A20 FNS-AX3 B50C in service FNS-AX4-B63 FNS-AX4-A20 in service FNS-AX4-B63 in service Old model image Standard shift & model IEC 61000-4-4 Ed.1 FNS-105L FNS-105AX FNS-2002 FNS-AX2-A16 FNS-AX2-B50 FNS-100AX FNS-100L FNS-101AX FNS-101L FNS-103L FNS-104L FNS-2002 FNS-AX2-B50 FNS-AX3-A16 FNS-AX3-B50 FNS-AX3-A16A FNS-AX3-B50A FNS-AX3-A16B FNS-AX3-B50B FNS-AX3-A16B FNS-AX3-B50B FNS-AX3-A16C FNS-AX3-B50C FNS-AX4-A20 FNS-AX4-B63 IEC 61000-4-4 Ed.3.0 IEC 61000-4-4 Ed.2.0(2004) Corrigendum2 Amendment1 Products in this range do not support the latest standards. FNS-AX2series FNS-AX3series FNS-AX3series(Late type) FNS-100Lseries FNS-100AXseries FNS-2002 EFT/B simulator after service and support notice

Transcript of EFT/B simulator after service and support notice · Taking account of field troubles is possible....

Page 1: EFT/B simulator after service and support notice · Taking account of field troubles is possible. (option) Utilize a tri-color pilot light to carry out safer test. (option) Utilize

1 www. n o i s e k e n . c om

The fast transient / burst simulator you always use is renewed now. For repair maintenance in our company, we discontinue repair support 8 years after delivery according to warranty and 5 years after sales termination. After that, we may decline to repair. We inform you of the following fast transient burst simulator's repair support status, compliant standard and successor product.

Standard shift & modelModel Repair service and support status successive mode

FNS-029series terminated FNS-AX4series

FNS-100AXseries terminated FNS-AX4series

FNS-100Lseries terminated FNS-AX4series

FNS-101AXseries terminated FNS-AX4series

FNS-101Lseries terminated FNS-AX4series

FNS-103L terminated FNS-AX4series

FNS-104Lseries terminated FNS-AX4series

FNS-105AX terminated FNS-AX4series

FNS-105L terminated FNS-AX4series

FNS-AX2 A16 terminated FNS-AX4-A20

FNS-AX2 B50 terminated FNS-AX4-B63

Standard shift & modelModel Repair service and support status successive mode

FNS-AX2 B50 terminated FNS-AX4-B63

FNS-2002 terminated FNS-AX4-A20

FNS-AX3 A16 terminated FNS-AX4-A20

FNS-AX3 B50 terminated FNS-AX4-B63

FNS-AX3 A16A terminated FNS-AX4-A20

FNS-AX3 B50A terminated FNS-AX4-B63

FNS-AX3 A16B partially terminated FNS-AX4-A20

FNS-AX3 B50B partially terminated FNS-AX4-B63

FNS-AX3 A16C in service FNS-AX4-A20

FNS-AX3 B50C in service FNS-AX4-B63

FNS-AX4-A20 in service -

FNS-AX4-B63 in service -Old model image

Standard shift & model

IEC 61000-4-4 Ed.1

FNS-105LFNS-105AXFNS-2002

FNS-AX2-A16FNS-AX2-B50

FNS-100AXFNS-100L

FNS-101AXFNS-101LFNS-103L FNS-104L

FNS-2002FNS-AX2-B50FNS-AX3-A16FNS-AX3-B50

FNS-AX3-A16AFNS-AX3-B50A

FNS-AX3-A16BFNS-AX3-B50B

FNS-AX3-A16BFNS-AX3-B50BFNS-AX3-A16CFNS-AX3-B50CFNS-AX4-A20FNS-AX4-B63

IEC 61000-4-4 Ed.3.0IEC 61000-4-4 Ed.2.0(2004)

Corrigendum2 Amendment1

Products in this range do not support the latest standards.

FNS-AX2series FNS-AX3series FNS-AX3series(Late type)

FNS-100Lseries FNS-100AXseries FNS-2002

EFT/B simulator after service and support notice

Page 2: EFT/B simulator after service and support notice · Taking account of field troubles is possible. (option) Utilize a tri-color pilot light to carry out safer test. (option) Utilize

2 www. n o i s e k e n . c om

Fast transient / burst simulator

FNS-AX4-A20/B63

Easy to perform pre-test inspectionwith pre-check function

In the inspection prior to the test, a dedicated attenuator and an oscilloscope were required for waveform output check. Now FNS-AX4 has a built-in monitor circuit, makes it easy to perform pre-check inspection before testing by just connecting the waveform observation connector with the attached coaxial cable.

Remote control SoftwareRemote control Software is available

Android application in addition to Windows software is available for customer environment for setting test conditions, saving test results, recording test logs, report generation, etc. .

Easy to understand test settingsin "multi-language"

In addition to Japanese, operation in English, Korean, and Chinese are provided for easy understanding of the test setting and operation.

Coupling Balun ready for normal mode test

IEC 61000-4-4 standard has the provision of the common mode test only, but noise may enter the equipment in the normal mode in the field and malfunction may occur. ANSI C37.90.1 standard specifies for corresponding normal mode noise testing. FNS-AX4 can now perform the normal mode test complying with ANSI C 37.90.1 standard with an optional dedicated normal mode coupling balun.

Simple and Easy EUT power line connectionInjection phase indicator on front panelIn order to prevent mistakes in the connection of the power cable during the test, Front panel shows the connection destination at a glance. Also an outlet box (option) is available for the simple power connection.

Windows software Android application

● International Sales & Marketing SectionTEL : +81-(0)42-712-2051/FAX : +81-(0)42-712-2050

E-mail : [email protected]

URL : http://www.noiseken.com

1-4-4 Chiyoda, Chuo-ku, Sagamihara City, Kanagawa Pref. 252-0237 Japan

* Designs, appearances and specifications on the products are subject change without notice.* Designs, appearances and specifications on the products are subject change without notice.

● IEC 61000-4-4 Ed.3 standard compliance. ● Pre-check function is installed. Inspection before testing is now easy. ● Normal mode test support. Taking account of field troubles is possible. (option) ● Utilize a tri-color pilot light to carry out safer test. (option) ● Utilize an outlet box that simplifies EUT connection. (option) ● Compared with conventional products, the size has become compact. (Approximately 67% by volume) ● Easy to understand Panel display reduces mistakes in connecting power cables. ● Software control with Android ™ and Windows. (option) ● Next calibration date can be notified. (Android / Windows software only) ● Employ LCD screen with multi-language support and enhanced operability. ● Maximum output voltage of 5 kV and maximum pulse frequency of 2 MHz allow you to test above the standard test level. ● CDN capacity is increased to single phase type AC 240V 20A, single and three phase type to AC 600 V 63 A, supporting wider range of EUT. ● Large capacity CDN (100A or 150A) option available for Injection test on various EUT ● Using coupling clamps, EMS probe kits, you can test the signal lines and evaluate the noise immunity on the PCB. (option) ● Easy-to-understand help function. (Android / Windows software only)

Information on successive model (current model)