Efland Direct Testimony - Indiana · VERIFIED DIRECT TESTIMONY OF AMY EFLAND 1 Q1. Please state...

29
Petitioner’s Exhibit No. 16 Northern Indiana Public Service Company LLC Page 1 VERIFIED DIRECT TESTIMONY OF AMY EFLAND Q1. Please state your name, business address and title. 1 A1. My name is Amy Efland. My business address is 290 W. Nationwide Blvd., 2 Columbus, Ohio 43215. I am currently the Manager of Demand 3 Forecasting for NiSource Corporate Services Company. 4 Q2. On whose behalf are you submitting this direct testimony? 5 A2. I am submitting this testimony on behalf of Northern Indiana Public Service 6 Company LLC (“NIPSCO”). 7 Q3. Please describe your educational and employment background. 8 A3. I attended Earlham College where I earned a Bachelor of Arts Degree in 9 Economics and Miami University where I earned a Master of Arts Degree 10 in Economics. From 1997 to 2002, I worked as a forecast analyst for Cinergy, 11 assisting with the production of the gas and electric longterm forecasts of 12 customers, energy consumption and peak demand for the Cinergy (Public 13 Service Indiana, Union Light, Heat & Power, and Cincinnati Gas & Electric) 14 territories. I was promoted to Lead Analyst in 2002, a position I held until 15 45159

Transcript of Efland Direct Testimony - Indiana · VERIFIED DIRECT TESTIMONY OF AMY EFLAND 1 Q1. Please state...

  • Petitioner’s Exhibit No. 16 Northern Indiana Public Service Company LLC 

    Page 1 

    VERIFIED DIRECT TESTIMONY OF AMY EFLAND  

    Q1. Please state your name, business address and title. 1 

    A1. My name is Amy Efland.  My business address is 290 W. Nationwide Blvd., 2 

    Columbus,  Ohio    43215.    I  am  currently  the  Manager  of  Demand 3 

    Forecasting for NiSource Corporate Services Company.   4 

    Q2. On whose behalf are you submitting this direct testimony? 5 

    A2. I am submitting this testimony on behalf of Northern Indiana Public Service 6 

    Company LLC (“NIPSCO”). 7 

    Q3. Please describe your educational and employment background. 8 

    A3. I attended Earlham College where  I earned a Bachelor of Arts Degree  in 9 

    Economics and Miami University where I earned a Master of Arts Degree 10 

    in Economics.  From 1997 to 2002, I worked as a forecast analyst for Cinergy, 11 

    assisting with the production of the gas and electric long‐term forecasts of 12 

    customers, energy consumption and peak demand for the Cinergy (Public 13 

    Service Indiana, Union Light, Heat & Power, and Cincinnati Gas & Electric) 14 

    territories.  I was promoted to Lead Analyst in 2002, a position I held until 15 

    45159

    loldhamNew Stamp

  • Petitioner’s Exhibit No. 16 Northern Indiana Public Service Company LLC 

    Page 2  

    I left Cinergy in 2005.  From 2005 to 2006, I worked as a Senior Forecasting 1 

    Analyst with Limited Brands/Victoria’s Secret Direct.  I provided analysis 2 

    and  recommendations  surrounding  circulation  levels  of  catalogues  and 3 

    assisted with catalogue messaging relating to marketing offers.  From 2006 4 

    to 2008, I worked as a Senior Marketing Analyst for JP Morgan Chase where 5 

    I was  responsible  for  the development of  test designs  for  consumer and 6 

    business banking marketing programs.  I joined NiSource Inc. in 2008 as a 7 

    Senior Forecast Analyst.  In 2014, my title was changed to Lead Forecasting 8 

    Analyst reflecting the same responsibilities I held while a Senior Forecast 9 

    Analyst.  I accepted my current position of Manager Demand Forecasting 10 

    on November 1, 2017. 11 

    Q4. What are your responsibilities as Manager Demand Forecasting? 12 

    A4. As  Manager  of  Forecasting,  my  principal  responsibilities  include  the 13 

    development  of  the  short‐range  and  long‐range  forecasts  of  customers, 14 

    energy  consumption  and  peak  demand  for  all  NiSource  distribution 15 

    companies  including  NIPSCO.    I  also  manage  other  business‐related 16 

    analyses and forecasts.  17 

  •   Petitioner’s Exhibit No. 16 Northern Indiana Public Service Company LLC 

      Page 3  

       

    Q5. Have  you  previously  testified  before  this  or  any  other  regulatory 1 

    commission? 2 

    A5. Yes.    I  testified  before  the  Indiana  Utility  Regulatory  Commission 3 

    (“Commission”)  in NIPSCO’s  gas  rate  case  in Cause No.  44988.    I  also 4 

    testified related to weather normalization and customer usage trends before 5 

    the  Pennsylvania  Public  Utility  Commission  in  Docket  Nos.  R‐2009‐6 

    2149262, R‐2010‐2215623, R‐2012‐2321748, R‐2014‐2406274, R‐2015‐2468056, 7 

    R‐2016‐2529660, the Kentucky Public Service Commission in Case No. 2009‐8 

    00141,  and  before  the Massachusetts  Department  of  Public  Utilities  in 9 

    support  of  the  2017  forecast  and  supply  plan  for  Columbia  Gas  of 10 

    Massachusetts in D.P.U. 17‐166.   11 

    Q6. Are you sponsoring any attachments to your testimony in this Cause? 12 

    A6. Yes.  I am sponsoring Attachment 16‐A and Attachment 16‐B, both of which 13 

    were prepared by me or under my direction and supervision.   14 

    Q7. What is the purpose of your testimony? 15 

    A7. The  purpose  of my  testimony  is  to  explain  how  the  historic  test  year 16 

    kilowatt  hour  (“kWh”)  consumption  was  adjusted  to  reflect  the  kWh 17 

    consumption that would have occurred had weather been normal and why 18 

  • Petitioner’s Exhibit No. 16 Northern Indiana Public Service Company LLC 

    Page 4  

    this is the appropriate level to use for ratemaking.  I also explain the base 1 

    load  temperature‐sensitive  load  normalization  procedure.    Finally,  I 2 

    explain the forecast method used to derive the Forward Test Year (period 3 

    beginning January 1, 2019 and ending December 31, 2019) customers and 4 

    volume and propose an adjustment to align the forecast with the definition 5 

    of normal weather proposed for ratemaking purposes. 6 

    Weather Normalization 7 

    Q8. Is NIPSCO proposing an adjustment to reflect normal weather? 8 

    A8. Yes. 9 

    Q9. Why  is an adjustment  to electric utility revenues  to normalize weather 10 

    appropriate? 11 

    A9. Electric  rates  include  charges  that  are  tied  to kWh  consumption.   These 12 

    charges  are  developed  by  dividing  required  revenue  by  units  of 13 

    consumption  from  the  test  year  period.    Because  these  charges  are 14 

    dependent on energy consumption, variations in weather would affect the 15 

    costs  allocated  to  each  unit  of  energy.    For  example,  calculating  these 16 

    charges  based  on  a  test  year with  abnormally  low  consumption would 17 

    result  in a higher allocation of costs  to each unit of energy consumed;  in 18 

  •   Petitioner’s Exhibit No. 16 Northern Indiana Public Service Company LLC 

      Page 5  

       

    subsequent years when normal levels of consumption are experienced, the 1 

    rates established would lead to an over‐collection of revenues. 2 

    Q10. Please describe NIPSCO’s weather normalization procedure. 3 

    A10. NIPSCO  used  the  base  load/temperature‐sensitive  load  normalization 4 

    procedure approved by the Commission in its 44688 Order.  This procedure 5 

    identifies a  level of  energy units per  customer  that  is not dependent on 6 

    weather (base load) and subtracts that from total energy units per customer 7 

    to  derive  temperature‐sensitive  energy  units  per  customer.    The 8 

    temperature‐sensitive energy units per customer were then multiplied by 9 

    the ratio of normal cooling degree days (“CDD”) to actual CDD to obtain 10 

    normal  temperature‐sensitive  energy  units  per  customer.    The  normal 11 

    temperature‐sensitive energy units per customer is then added to the base 12 

    load energy units per customer to arrive at the normal total energy units 13 

    per customer, which is then multiplied by the number of customers to yield 14 

    the normal units for the month.  NIPSCO used three sources of data in its 15 

    analysis:  (1) monthly billing data from its actual billing records, (2) NOAA1 16 

    National Weather Service Weather Stations data  for actual  temperatures 17 

                                                     1   National Oceanic and Atmospheric Administration 

  • Petitioner’s Exhibit No. 16 Northern Indiana Public Service Company LLC 

    Page 6  

    used  to  calculate CDD, and  (3)  the 30‐year average of  temperature data 1 

    from 1988‐2017 using NOAA’s National Weather Service temperatures. 2 

    The weather normalization procedure assumed there was no temperature‐3 

    sensitive load in the month of May; therefore, the daily volumes recorded 4 

    in the month of May divided by the number of customers represented the 5 

    customer daily base  load volume.   NIPSCO used  the  following weather 6 

    normalization  procedure  for  the  Cooling  Season months  of  June,  July, 7 

    August and September: 8 

    1.    The  base  load  per  customer  was  calculated  for  each  month  by 9 

    multiplying the customer daily base load by the number of days in 10 

    each billing month. 11 

    2.    The  temperature‐sensitive  load per  customer  for  each month was 12 

    calculated by subtracting the base load per customer from the total 13 

    load per customer. 14 

    3.    The normal temperature‐sensitive load per customer was calculated 15 

    by multiplying the temperature‐sensitive load per customer by the 16 

    ratio of normal CDD to actual CDD. 17 

  •   Petitioner’s Exhibit No. 16 Northern Indiana Public Service Company LLC 

      Page 7  

       

    4.    The normal  load per customer was calculated by adding  the base 1 

    load  per  customer  to  the  normal  temperature‐sensitive  load  per 2 

    customer. 3 

    5.    The normal volume was then calculated by multiplying the normal 4 

    load per customer by the customer count.    5 

    Q11. What is CDD? 6 

    A11. CDD is a unit used to relate a day’s temperature to the energy demands of 7 

    air  conditioning.  CDD  are  calculated  by  subtracting  the  balance  point 8 

    temperature,  65,  from  a day’s  average  temperature.  For  example,  if  the 9 

    day’s high temperature and low temperature ranged from 90°F to 70°F, and 10 

    the  average  temperature was  80°F, CDD  is  calculated by  subtracting  65 11 

    from 80, which results in 15 CDD for that day.   12 

    Q12. What is the definition of a Balance Point Temperature? 13 

    A12. Balance  Point  Temperature  is  the  average  daily  temperature  used  as  a 14 

    reference level for calculating CDD.   15 

    Q13. Has  the  normalization  procedure  been  updated  since  the  44688  Rate 16 

    Case?   17 

  • Petitioner’s Exhibit No. 16 Northern Indiana Public Service Company LLC 

    Page 8  A13. Yes.   NIPSCO has updated its definition of normal weather.   In 2015, the 1 

    Company defined normal weather as the 30‐year average ending in 2014.  2 

    In this filing, NIPSCO has defined normal weather as the 30‐year average 3 

    ending  in  2017, which  is  an  update  to  the  normal CDDs  calculated  by 4 

    NOAA’s National Weather Service, which uses data for the 30‐year period 5 

    ended  2010.   Given  its  10‐year  cycle  for updating  a  large  set  of  climate 6 

    variables, NOAA’s National Weather Service will next  issue new normal 7 

    CDDs  for  the period 1991‐2020.   In  the 44688 Rate Case, normal weather 8 

    was defined as the 30‐year average ending 2014.  9 

    Q14. Which weather stations were used to determine the weather throughout 10 

    NIPSCO’s service territory? 11 

    A14. Weather stations in Valparaiso, South Bend and Fort Wayne were weighted 12 

    by  the  number  of  residential  customers  assigned  to  those  stations  to 13 

    represent the NIPSCO service territory.  14 

    Q15. What are the volumetric results of NIPSCO’s weather normalization?   15 

    A15. With actual CDD lower than normal by 6%, the test year was cooler than 16 

    normal, and usage for the adjusted rates was adjusted up by 0.8% to reflect 17 

    normal  weather.    NIPSCO  Witness  Westerhausen  uses  the  weather 18 

  •   Petitioner’s Exhibit No. 16 Northern Indiana Public Service Company LLC 

      Page 9  

       

    adjusted volumes to calculate pro‐forma expense and revenue levels.  The 1 

    weather data used to develop the CDD for the adjustment is summarized 2 

    in Table 3. 3 

    Table 3 4 

     5  6 

    Q16. How can CDD be used to compare the current Cooling Season to a past 7 

    Cooling Season? 8 

    A16. CDD are accumulated daily so that a month’s CDD is the sum of the daily 9 

    CDD. A high  level of CDD  indicates many days with high  temperatures 10 

    and is associated with a high level of kWh consumption. The level of CDD 11 

    can be compared from month‐to‐month or summer‐to‐summer to indicate 12 

    the  relative  amount  of  hot weather.  The  702  CDD  during  the  Cooling 13 

    Season of  the  test year  is  lower  than  the average of 747 CDD during  the 14 

    Cooling Season for the 30‐year period 1988 to 2017.   15 

    Weighted Sum of CDD for NIPSCOCDD by Weather Station Valparaiso South Bend Fort Wayne Weighted Sum

    Actual Month Valparaiso South Bend Fort Wayne 63% 19% 18%Jun 152 106 125 96 20 23 138Jul 267 196 233 168 37 42 247Aug 217 168 197 137 32 35 204Sep 126 89 94 79 17 17 113

    Season 762 559 649 480 106 117 702

    Normal MonthJun 118 118 127 74 22 23 120Jul 237 238 252 149 45 45 240Aug 230 235 235 145 45 42 232Sep 154 160 151 97 30 27 155

    Season 739 751 765 466 143 138 747

    Actual versus Normal Difference -6%

  • Petitioner’s Exhibit No. 16 Northern Indiana Public Service Company LLC 

    Page 10  Q17. Please  discuss  electric  consumption  due  to  lower  than  average  CDD 1 

    during the test year. 2 

    A17. In simple terms, the data indicates that during the Cooling Season, either 3 

    the  days were  cooler  than  average  or  there were more  cool  days  than 4 

    average  resulting  in  customers operating  their air  conditioners  less  than 5 

    normal  and  thereby  consuming  less  electric  energy  than  normal.  I  can 6 

    conclude, based on this data, that the amount of electric energy consumed 7 

    during the test year is abnormally low and that the test year does not reflect 8 

    a representative level for ratemaking purposes. 9 

    Q18. Does the data show that kWh consumption varies with CDD? 10 

    A18. Yes,  it does. The  relationship between CDD  and kWh  consumption per 11 

    customer  for  the Cooling Season during  the period 2008  to 2017  for  the 12 

    residential class is depicted in the following graph: 13 

  •   Petitioner’s Exhibit No. 16 Northern Indiana Public Service Company LLC 

      Page 11  

       

     1 

    The graph  shows a  strong  correlation between CDD and electric energy 2 

    consumed. Additionally, the graph also shows that the 702 CDD and the 3 

    kWh consumed during the Cooling Season of the test year are low when 4 

    compared to the average of 747 CDD.  The 2017 Cooling Season is the 14th 5 

    lowest Cooling Season for the 30 years ended 2017.  6 

    Q19. What do you conclude from this data? 7 

    A19. A strong relationship between kWh consumption and CDD, combined with 8 

    CDD less than the level observed in 53 percent of the 30 years ended 2017, 9 

    leads  to  the conclusion  that kWh consumption should be normalized  for 10 

    weather so that it is stated at a level representative for ratemaking purposes. 11 

  • Petitioner’s Exhibit No. 16 Northern Indiana Public Service Company LLC 

    Page 12  Results of Weather Normalization 1 

    Q20. What are the results of your weather normalization? 2 

    A20. The weather normalization adjustment reduces volume in two (2) and adds 3 

    volume  in  two  (2) of  the  four  (4) months  in  the Cooling Season. The net 4 

    effect is an increase of 59,151,141 kWh or 0.8% of the annual volume for the 5 

    adjusted rates. 6 

    Q21. Have  you  demonstrated  the  details  of  the  weather  normalization 7 

    procedure? 8 

    A21. Yes, the details are shown in Attachment 16‐A. 9 

    Forward Test Year 10 

    Q22. How were the projections for the Forward Test Year developed? 11 

    A22. The customer and energy projections utilized in the budget are developed 12 

    by NIPSCO’s Forecasting Group with  input  from Major Accounts, New 13 

    Business, and Financial Planning.  The Forecasting Group is responsible for 14 

    most concepts, with New Business providing projections of residential and 15 

    commercial  new  customer  additions.   Major Accounts  provides  budget 16 

    projections  for  large  industrial  customers,  while  Financial  Planning 17 

    supplies an outlook for all other small industrial customers utilized in the 18 

    budget.  19 

  •   Petitioner’s Exhibit No. 16 Northern Indiana Public Service Company LLC 

      Page 13  

       

    The methodology used to estimate both customer and usage is presented in 1 

    the summary below.  Price information included in the models is from the 2 

    Company’s databases, and average saturation and efficiency data is from 3 

    Itron Inc., a national utility consulting firm.   The economic variables and 4 

    deflator  information are  from  IHS Global  Insight,  Inc., a data consultant, 5 

    and weather data is provided by Schneider Electric, a weather consulting 6 

    service.    The  energy  usage  models  utilize  both  Heating  Degree  Days 7 

    (“HDDs”) and CDDs when estimating the Forward Test year level of usage.   8 

    Q23. What is HDD? 9 

    A23. HDD is a unit used to relate a day’s temperature to the energy demands of 10 

    primarily space heating and electric water heating.  HDD are calculated by 11 

    subtracting  the  day’s  average  temperature  from  the  balance  point 12 

    temperature of 65.   For example,  if  the day’s high  temperature and  low 13 

    temperature ranged from 20°F to 40°F, and the average temperature was 14 

    30°F, HDD is calculated by subtracting 30 from 65, which results in 35 HDD 15 

    for that day.   16 

    Q24. Please describe the forecast methodology used to develop the budget. 17 

    A24. The  methodology is summarized as follows: 18 

  • Petitioner’s Exhibit No. 16 Northern Indiana Public Service Company LLC 

    Page 14  

    Residential and Commercial Customers 

    Residential  customer projections  are  developed  utilizing  the  new 1 

    customer  additions  provided  by NIPSCO’s New  Business  Team. 2 

    New Business identifies potential new projects, both rural extension 3 

    and  non‐rural  growth  projects, monitors  potential  projects  being 4 

    engineered, residential single family and multi‐family construction 5 

    permit  applications,  and  outstanding  electric  service  requests.  6 

    Subsequent years are developed based on the team’s knowledge of 7 

    the business climate, new construction activity and interviews with 8 

    active builders and developers. Customer attrition is estimated to be 9 

    at  a  typical  historical  level  by  the  Forecasting  Group.    Total 10 

    residential  customers  are  calculated  by  incorporating  the  new 11 

    customer outlook, existing customers and the historic attrition rate.  12 

    Commercial customers are estimated utilizing an econometric model 13 

    that incorporates local population and real gross county product.  As 14 

    with  residential,  the New  Business  team  provides  new  customer 15 

    projections  that  are  incorporated  into  the  total  customer  outlook.  16 

    Attrition is reflected at a historical rate. 17 

  •   Petitioner’s Exhibit No. 16 Northern Indiana Public Service Company LLC 

      Page 15  

       

    Residential and Commercial Usage 

    The  residential  use  per  customer  model  is  estimated  using  an 1 

    econometric model incorporating the residential price of electricity, 2 

    appliance  saturations  and  efficiencies  as  defined  in  an  end  use 3 

    variable supplied by Itron, Inc., real per capita  income,   HDD and 4 

    CDD.  Total residential volume is calculated by multiplying the total 5 

    customer projections by the usage per customer outlook. 6 

    Commercial usage  is  estimated using a  total  energy  consumption 7 

    model.   Commercial  total  energy  is  a  function  of  the  commercial 8 

    customer count, employment, commercial electric price, HDD and 9 

    CDD.  10 

    Industrial Volume 

    The Industrial Energy Forecast Model projects the expected level of 11 

    industrial  energy  sales  in  NIPSCO’s  service  territory  based  on 12 

    individual discussions with  its  largest  industrial customers, recent 13 

    historical  industrial  sales  trends,  and  specific  industry  trends.  14 

    Accordingly,  the  industrial  energy  outlook  models  contains 15 

    individual projections for the major industrial account customers. 16 

  • Petitioner’s Exhibit No. 16 Northern Indiana Public Service Company LLC 

    Page 16  

    The industrial sales projections also integrate a sales outlook for the 1 

    remaining industrial accounts (identified as Other Industrial).  This 2 

    portion  of  the  NIPSCO  electric  budget  is  based  primarily  on 3 

    historical data (billed volume) from the past six years with greater 4 

    consideration given  to use  for  the most  recent year.   Annual and 5 

    monthly  volumes were  analyzed  ‐ min, max,  and  averages were 6 

    calculated.  Historical trends, if any, were identified and are reflected 7 

    in the projections. 8 

    Public Authority, Railroads, Company Use, Street Lighting, Losses 

    Public authority, railroads, Company use and losses are all based on 9 

    both current usage  levels and anticipated  future trends. The street 10 

    lighting model utilizes  an  econometric  approach  to model  future 11 

    street lighting usage. 12 

    Peak  

    NIPSCO uses an econometric model to project future peak demand 13 

    on its system.  The model incorporates residential, commercial, and 14 

    industrial  energy  levels,  cooling  degrees  (summer)  and  heating 15 

    degrees (winter) at peak hour, and the level of relative humidity at 16 

    peak hour.  The model also accounts for recent historical load factor 17 

  •   Petitioner’s Exhibit No. 16 Northern Indiana Public Service Company LLC 

      Page 17  

       

    levels  and  patterns  associated  with  NIPSCO’s  large  industrial 1 

    customers.   2 

    Q25. What  definition  of weather  normal  is  reflected  in  the  2018  and  2019 3 

    Budget?  4 

    A25. The budget was developed using  the definition of normal  for both CDD 5 

    and HDD of 35 years ended 2010.   6 

    Q26. What definition of weather normal is reflected in the forecast?  7 

    A26. The forecast was developed using the definition of normal for both CDD 8 

    and HDD of 30 years ended 2017.  This is consistent with the definition used 9 

    in  the  normalization  of  the Historic  Test  Year.  The  Forward  Test  Year 10 

    forecast was  provided  to NIPSCO Witness Westerhausen  as  shown  on 11 

    Attachment 16‐B and utilized as an  input  in Adjustment REV 1A‐19R as 12 

    shown on Petitioner’s Exhibit No. 4, Attachment 4‐C‐S2, REV 1A19R.  13 

    Q27. Please discuss the past performance of the forecast methodology used in 14 

    this case.  15 

    A27. Forecasts are updated annually with  the most current data.   An  internal 16 

    review of the forecast performance occurs on a regular basis.  Variances are 17 

    calculated  and  assessed  in order  to measure  accuracy.   For  the  last  five 18 

  • Petitioner’s Exhibit No. 16 Northern Indiana Public Service Company LLC 

    Page 18  

    years,  the average annual one year weather normalized variance  for  the 1 

    residential model is 1.8%.  For commercial, the average one year variance 2 

    of  the  forecast  is  1.5%.    The  more  volatile  industrial  forecast  average 3 

    variance was 3.8%.  4 

    Q28. Does this conclude your prefiled direct testimony? 5 

    A28. Yes. 6 

  • NIPSCO Normalization For 12 Months Ending December 2017

    711 711 721 721 723 723 724 724 726 726Actual KWH 1 3 4 5 4 5 4 5 4 5 Total

    1 314,286,192 291,522 115,863,076 790,478 86,180,525 179,617 44,770,194 13,539,786 29,768,903 20,965,252 626,635,545 2 258,362,673 239,244 108,686,385 979,962 82,002,086 190,479 43,261,612 12,805,220 29,216,270 19,115,410 554,859,341 3 231,939,486 227,394 101,898,881 1,087,854 79,603,287 177,703 42,400,381 12,134,969 29,089,958 19,753,626 518,313,539 4 223,091,374 207,397 102,055,297 1,249,131 80,095,767 171,119 44,295,207 11,967,893 30,191,925 19,122,206 512,447,316 5 193,919,857 180,923 93,685,327 948,055 76,573,396 178,017 42,574,956 11,665,266 28,966,407 19,908,198 468,600,402 6 287,925,637 249,645 118,035,707 1,088,684 93,210,205 217,855 51,070,197 14,210,663 35,300,053 22,151,782 623,460,428 7 366,786,920 316,635 127,242,033 1,067,344 96,116,467 196,153 51,454,406 14,316,579 37,679,053 24,368,668 719,544,258 8 360,715,160 298,234 130,066,513 1,183,715 96,520,908 176,483 49,890,630 13,406,691 34,991,469 23,236,592 710,486,395 9 297,142,847 264,054 122,997,463 1,303,110 95,590,892 234,770 52,885,373 15,023,615 37,023,316 22,630,690 645,096,130

    10 263,136,683 264,575 112,184,610 1,416,033 87,819,707 219,637 49,309,677 14,396,710 33,356,579 21,195,526 583,299,737 11 229,294,401 283,330 107,599,450 1,211,605 79,539,582 175,106 45,875,177 14,056,016 30,218,666 19,367,898 527,621,231 12 254,476,105 267,420 106,893,400 1,146,303 76,167,005 168,472 43,396,805 12,472,831 28,284,126 18,455,124 541,727,591

    Annual 3,281,077,335 3,090,373 1,347,208,142 13,472,274 1,029,419,827 2,285,411 561,184,615 159,996,239 384,086,725 250,270,972 7,032,091,913

    Normal KWH1 314,286,192 291,522 115,863,076 790,478 86,180,525 179,617 44,770,194 13,539,786 29,768,903 20,965,252 626,635,545 2 258,362,673 239,244 108,686,385 979,962 82,002,086 190,479 43,261,612 12,805,220 29,216,270 19,115,410 554,859,341 3 231,939,486 227,394 101,898,881 1,087,854 79,603,287 177,703 42,400,381 12,134,969 29,089,958 19,753,626 518,313,539 4 223,091,374 207,397 102,055,297 1,249,131 80,095,767 171,119 44,295,207 11,967,893 30,191,925 19,122,206 512,447,316 5 193,919,857 180,923 93,685,327 948,055 76,573,396 178,017 42,574,956 11,665,266 28,966,407 19,908,198 468,600,402 6 279,169,434 243,939 116,592,740 1,088,684 92,489,710 217,855 50,865,527 14,088,701 34,487,883 22,099,403 611,343,8777 362,405,754 313,248 126,537,356 1,067,344 95,796,002 196,153 51,332,042 14,273,721 37,412,174 24,272,577 713,606,3708 381,982,382 312,887 134,295,178 1,183,715 98,492,973 176,483 50,530,745 13,545,977 35,805,424 23,639,332 739,965,0979 327,414,233 287,699 130,482,416 1,303,110 99,313,740 234,770 54,802,923 15,768,202 40,102,503 23,113,413 692,823,009

    10 263,136,683 264,575 112,184,610 1,416,033 87,819,707 219,637 49,309,677 14,396,710 33,356,579 21,195,526 583,299,737 11 229,294,401 283,330 107,599,450 1,211,605 79,539,582 175,106 45,875,177 14,056,016 30,218,666 19,367,898 527,621,231 12 254,476,105 267,420 106,893,400 1,146,303 76,167,005 168,472 43,396,805 12,472,831 28,284,126 18,455,124 541,727,591

    Annual 3,319,478,574 3,119,577 1,356,774,116 13,472,274 1,034,073,781 2,285,411 563,415,247 160,715,292 386,900,817 251,007,965 7,091,243,054

    Difference1 - - - - - - - - - - - 2 - - - - - - - - - - - 3 - - - - - - - - - - - 4 - - - - - - - - - - - 5 - - - - - - - - - - - 6 (8,756,203) (5,706) (1,442,967) - (720,495) - (204,670) (121,962) (812,170) (52,379) (12,116,551) 7 (4,381,166) (3,387) (704,677) - (320,465) - (122,364) (42,858) (266,879) (96,091) (5,937,888) 8 21,267,222 14,653 4,228,665 - 1,972,065 - 640,115 139,286 813,955 402,740 29,478,702 9 30,271,386 23,645 7,484,953 - 3,722,848 - 1,917,550 744,587 3,079,187 482,723 47,726,879

    10 - - - - - - - - - - - 11 - - - - - - - - - - - 12 - - - - - - - - - - -

    Annual 38,401,240 29,204 9,565,974 0 4,653,954 0 2,230,632 719,053 2,814,092 736,993 59,151,141Annual % 1.2% 0.9% 0.7% 0.0% 0.5% 0.0% 0.4% 0.4% 0.7% 0.3% 0.8%Seasonal % 2.9% 2.6% 1.9% 0.0% 1.2% 0.0% 1.1% 1.3% 1.9% 0.8% 2.2%

    Petitioner's Exhibit No. 16 Attachment 16-A

    Page 1 of 9

  • NIPSCO Normalization Normal Weather 1988 2017 30 YearsRate 711

    1Weather Adjustment Calculation

    1 2 3 = 2/1 4 = 3/12 5 = 4 (May#) *12 6 = 3-5 7 = 5+(6*(11/10)) 8 = 1*7 9= 8-2 10 11 12

    Actual Actual Actual Base Temperature Sensitive Normal Normal Weather CDD CDDCustomers KWH KWH/Cus KWH/Cus/Day KWH/Cus KWH/Cus KWH/Customer KWH Adjustment Actual Normal Days

    2017 1 314,286,192 314,286,1922017 2 258,362,673 258,362,6732017 3 231,939,486 231,939,4862017 4 223,091,374 223,091,3742017 5 410,594 193,919,857 472 16.70 472 - 193,919,857 28.32017 6 410,789 287,925,637 701 21.77 537 163 680 279,169,434 -8,756,203 138 120 32.22017 7 409,320 366,786,920 896 28.86 518 378 885 362,405,754 -4,381,166 247 240 31.02017 8 410,134 360,715,160 880 29.27 502 378 931 381,982,382 21,267,222 204 232 30.02017 9 409,176 297,142,847 726 23.00 527 199 800 327,414,233 30,271,386 113 155 31.62017 10 263,136,683 263,136,6832017 11 229,294,401 229,294,4012017 12 254,476,105 254,476,105

    Petitioner's Exhibit No. 16 Attachment 16-A

    Page 2 of 9

  • NIPSCO Normalization Normal Weather 1988 2017 30 YearsRate 711

    3Weather Adjustment Calculation

    1 2 3 = 2/1 4 = 3/12 5 = 4 (May#) *12 6 = 3-5 7 = 5+(6*(11/10)) 8 = 1*7 9= 8-2 10 11 12

    Actual Actual Actual Base Temperature Sensitiv Normal Normal Weather CDD CDDCustomers KWH KWH/Cus KWH/Cus/Day KWH/Cus KWH/Cus KWH/Customer KWH Adjustment Actual Normal Days

    2017 1 291,522 291,5222017 2 239,244 239,2442017 3 227,394 227,3942017 4 207,397 207,3972017 5 269 180,923 673 23.78 673 - 180,923 28.32017 6 269 249,645 928 28.83 765 163 907 243,939 -5,706 138 120 32.22017 7 267 316,635 1,186 38.20 738 448 1,173 313,248 -3,387 247 240 31.02017 8 268 298,234 1,113 37.03 714 398 1,167 312,887 14,653 204 232 30.02017 9 267 264,054 989 31.32 751 238 1,078 287,699 23,645 113 155 31.62017 10 264,575 264,5752017 11 283,330 283,3302017 12 267,420 267,420

    Petitioner's Exhibit No. 16 Attachment 16-A

    Page 3 of 9

  • NIPSCO Normalization Normal Weather 1988 2017 30 YearsRate 721

    4Weather Adjustment Calculation

    1 2 3 = 2/1 4 = 3/12 5 = 4 (May#) *12 6 = 3-5 7 = 5+(6*(11/10)) 8 = 1*7 9= 8-2 10 11 12

    Actual Actual Actual Base Temperature Sensitiv Normal Normal Weather CDD CDDCustomers KWH KWH/Cus KWH/Cus/Day KWH/Cus KWH/Cus KWH/Customer KWH Adjustment Actual Normal Days

    2017 1 115,863,076 115,863,0762017 2 108,686,385 108,686,3852017 3 101,898,881 101,898,8812017 4 102,055,297 102,055,2972017 5 51,409 93,685,327 1,822 64.43 1,822 - 93,685,327 28.32017 6 51,580 118,035,707 2,288 71.09 2,074 214 2,260 116,592,740 -1,442,967 138 120 32.22017 7 51,181 127,242,033 2,486 80.07 2,000 486 2,472 126,537,356 -704,677 247 240 31.02017 8 51,273 130,066,513 2,537 84.42 1,936 601 2,619 134,295,178 4,228,665 204 232 30.02017 9 50,569 122,997,463 2,432 77.04 2,034 398 2,580 130,482,416 7,484,953 113 155 31.62017 10 112,184,610 112,184,6102017 11 107,599,450 107,599,4502017 12 106,893,400 106,893,400

    Petitioner's Exhibit No. 16 Attachment 16-A

    Page 4 of 9

  • NIPSCO Normalization Normal Weather 1988 2017 30 YearsRate 723

    4Weather Adjustment Calculation

    1 2 3 = 2/1 4 = 3/12 5 = 4 (May#) *12 6 = 3-5 7 = 5+(6*(11/10)) 8 = 1*7 9= 8-2 10 11 12

    Actual Actual Actual Base Temperature Sensitiv Normal Normal Weather CDD CDDCustomers KWH KWH/Cus KWH/Cus/Day KWH/Cus KWH/Cus KWH/Customer KWH Adjustment Actual Normal Days

    2017 1 86,180,525 86,180,5252017 2 82,002,086 82,002,0862017 3 79,603,287 79,603,2872017 4 80,095,767 80,095,7672017 5 3,214 76,573,396 23,825 842.30 23,825 - 76,573,396 28.32017 6 3,234 93,210,205 28,822 895.36 27,114 1,708 28,599 92,489,710 -720,495 138 120 32.22017 7 3,243 96,116,467 29,638 954.60 26,151 3,487 29,539 95,796,002 -320,465 247 240 31.02017 8 3,246 96,520,908 29,735 989.61 25,309 4,426 30,343 98,492,973 1,972,065 204 232 30.02017 9 3,218 95,590,892 29,705 940.88 26,592 3,113 30,862 99,313,740 3,722,848 113 155 31.62017 10 87,819,707 87,819,7072017 11 79,539,582 79,539,5822017 12 76,167,005 76,167,005

    Petitioner's Exhibit No. 16 Attachment 16-A

    Page 5 of 9

  • NIPSCO Normalization Normal Weather 1988 2017 30 YearsRate 724

    4Weather Adjustment Calculation

    1 2 3 = 2/1 4 = 3/12 5 = 4 (May#) *12 6 = 3-5 7 = 5+(6*(11/10)) 8 = 1*7 9= 8-2 10 11 12

    Actual Actual Actual Base Temperature Sensitiv Normal Normal Weather CDD CDDCustomers KWH KWH/Cus KWH/Cus/Day KWH/Cus KWH/Cus KWH/Customer KWH Adjustment Actual Normal Days

    2017 1 44,770,194 44,770,1942017 2 43,261,612 43,261,6122017 3 42,400,381 42,400,3812017 4 44,295,207 44,295,2072017 5 231 42,574,956 184,307 6515.91 184,307 - 42,574,956 28.32017 6 236 51,070,197 216,399 6722.46 209,750 6,649 215,532 50,865,527 -204,670 138 120 32.22017 7 233 51,454,406 220,834 7112.76 202,303 18,531 220,309 51,332,042 -122,364 247 240 31.02017 8 231 49,890,630 215,977 7187.82 195,788 20,189 218,748 50,530,745 640,115 204 232 30.02017 9 232 52,885,373 227,954 7220.27 205,717 22,238 236,219 54,802,923 1,917,550 113 155 31.62017 10 49,309,677 49,309,6772017 11 45,875,177 45,875,1772017 12 43,396,805 43,396,805

    Petitioner's Exhibit No. 16 Attachment 16-A

    Page 6 of 9

  • NIPSCO Normalization Normal Weather 1988 2017 30 YearsRate 724

    5Weather Adjustment Calculation

    1 2 3 = 2/1 4 = 3/12 5 = 4 (May#) *12 6 = 3-5 7 = 5+(6*(11/10)) 8 = 1*7 9= 8-2 10 11 12

    Actual Actual Actual Base Temperature Sensitiv Normal Normal Weather CDD CDDCustomers KWH KWH/Cus KWH/Cus/Day KWH/Cus KWH/Cus KWH/Customer KWH Adjustment Actual Normal Days

    2017 1 13,539,786 13,539,7862017 2 12,805,220 12,805,2202017 3 12,134,969 12,134,9692017 4 29 11,967,893 11,967,8932017 5 29 11,665,266 402,251 14220.98 402,251 - 11,665,266 28.32017 6 29 14,210,663 490,023 15222.60 457,780 32,243 485,817 14,088,701 -121,962 138 120 32.22017 7 29 14,316,579 493,675 15900.58 441,528 52,148 492,197 14,273,721 -42,858 247 240 31.02017 8 29 13,406,691 462,300 15385.57 427,307 34,993 467,103 13,545,977 139,286 204 232 30.02017 9 29 15,023,615 518,056 16409.00 448,977 69,079 543,731 15,768,202 744,587 113 155 31.62017 10 28 14,396,710 14,396,7102017 11 29 14,056,016 14,056,0162017 12 12,472,831 12,472,831

    Petitioner's Exhibit No. 16 Attachment 16-A

    Page 7 of 9

  • NIPSCO Normalization Normal Weather 1988 2017 30 YearsRate 726

    4Weather Adjustment Calculation

    1 2 3 = 2/1 4 = 3/12 5 = 4 (May#) *12 6 = 3-5 7 = 5+(6*(11/10)) 8 = 1*7 9= 8-2 10 11 12

    Actual Actual Actual Base Temperature Sensitiv Normal Normal Weather CDD CDDCustomers KWH KWH/Cus KWH/Cus/Day KWH/Cus KWH/Cus KWH/Customer KWH Adjustment Actual Normal Days

    2017 1 29,768,903 29,768,9032017 2 29,216,270 29,216,2702017 3 29,089,958 29,089,9582017 4 30,191,925 30,191,9252017 5 144 28,966,407 201,156 7111.56 201,156 - 28,966,407 28.32017 6 127 35,300,053 277,953 8634.64 228,925 49,029 271,558 34,487,883 -812,170 138 120 32.22017 7 128 37,679,053 294,368 9481.17 220,797 73,571 292,283 37,412,174 -266,879 247 240 31.02017 8 136 34,991,469 257,290 8562.75 213,686 43,605 263,275 35,805,424 813,955 204 232 30.02017 9 128 37,023,316 289,245 9161.60 224,522 64,722 313,301 40,102,503 3,079,187 113 155 31.62017 10 33,356,579 33,356,5792017 11 30,218,666 30,218,6662017 12 28,284,126 28,284,126

    Petitioner's Exhibit No. 16 Attachment 16-A

    Page 8 of 9

  • NIPSCO Normalization Normal Weather 1988 2017 30 YearsRate 726

    5Weather Adjustment Calculation

    1 2 3 = 2/1 4 = 3/12 5 = 4 (May#) *12 6 = 3-5 7 = 5+(6*(11/10)) 8 = 1*7 9= 8-2 10 11 12

    Actual Actual Actual Base Temperature Sensitiv Normal Normal Weather CDD CDDCustomers KWH KWH/Cus KWH/Cus/Day KWH/Cus KWH/Cus KWH/Customer KWH Adjustment Actual Normal Days

    2017 1 20,965,252 20,965,2522017 2 19,115,410 19,115,4102017 3 19,753,626 19,753,6262017 4 19,122,206 19,122,2062017 5 25 19,908,198 796,328 28153.01 796,328 - 19,908,198 28.32017 6 24 22,151,782 922,991 28672.79 906,259 16,732 920,808 22,099,403 -52,379 138 120 32.22017 7 24 24,368,668 1,015,361 32703.35 874,084 141,277 1,011,357 24,272,577 -96,091 247 240 31.02017 8 24 23,236,592 968,191 32221.90 845,931 122,260 984,972 23,639,332 402,740 204 232 30.02017 9 24 22,630,690 942,945 29867.05 888,831 54,115 963,059 23,113,413 482,723 113 155 31.62017 10 21,195,526 21,195,5262017 11 19,367,898 19,367,8982017 12 18,455,124 18,455,124

    Petitioner's Exhibit No. 16 Attachment 16-A

    Page 9 of 9

  • NIPSCO Electric Rate Case Forecast - 30 Year NormalNIPSCO MWH

    Year Residential Commercial2019 3,414,463 3,906,221

    NIPSCO Electric Forecast - 35 Year Normal NIPSCO MWH

    Year Residential Commercial2019 3,419,840 3,910,422

    Adjustment - MWHYear Residential Commercial Total 2019 (5,377) (4,201) (9,577)

    Petitioner's Exhibit No. 16 Attachment 16-B

    Attachment 16-A.pdfSummary711-1711-3 721-4723-4724-4724-5726-4726-5