(EFFECTIVE FROM 7 Oct., 2106)Executive Engineer, PWD Chief Engineer Office Jaipur, Shri Arun...

21
GOVERNMENT OF RAJASTHAN PUBLIC WORKS DEPARTMENT CITY CIRCLE - JAIPUR BASIC SCHEDULE OF RATES 2016 (EFFECTIVE FROM 7 th Oct., 2106) GENERAL BASIC RATES BUILDINGS WORKS SANITARY WORKS HORTICULTURE WORKS MISCELLANEOUS CIRCULARS AVAILABLE WITH EXECUTIVE ENGINEER, PWD CITY DIVISION II, JAIPUR Price : Rs. 600.00

Transcript of (EFFECTIVE FROM 7 Oct., 2106)Executive Engineer, PWD Chief Engineer Office Jaipur, Shri Arun...

Page 1: (EFFECTIVE FROM 7 Oct., 2106)Executive Engineer, PWD Chief Engineer Office Jaipur, Shri Arun Bhardwaj, Executive Engineer, PWD Chief Engineer Office Jaipur, Shri P.N. Maheshwari, A.En

GOVERNMENT OF RAJASTHAN

PUBLIC WORKS DEPARTMENT

CITY CIRCLE - JAIPUR

BASIC SCHEDULE OF RATES 2016

(EFFECTIVE FROM 7th Oct., 2106)

GENERAL BASIC RATES

BUILDINGS WORKS

SANITARY WORKS

HORTICULTURE WORKS

MISCELLANEOUS CIRCULARS

AVAILABLE WITH

EXECUTIVE ENGINEER,

PWD CITY DIVISION – II,

JAIPUR Price : Rs. 600.00

Page 2: (EFFECTIVE FROM 7 Oct., 2106)Executive Engineer, PWD Chief Engineer Office Jaipur, Shri Arun Bhardwaj, Executive Engineer, PWD Chief Engineer Office Jaipur, Shri P.N. Maheshwari, A.En

PREFACE

The basic schedule of Rate 2016 for building works has been prepared as a

revision of BSR-2014 for PWD City Circle, Jaipur. The Chief Engineer (NH) PWD

Rajasthan has approved the same vide his letter No. SE/NH /BSR/45/D-1411 dated

05.10.2016 Standard pattern of nomenclature for various items of building works has

been adopted in preparation of the BSR-2014. It contains almost all items required

for building works. Various items are based on standard PWD specification and

Bureau of Indian Standard Codes as amended/ revised form time to time and should

be read accordingly. It has been prepared on the basis of present prevailing market

rates in Jaipur.

Due care has been taken while preparing this BSR-2016 yet it is possible that

some typical or other errors might have left. Suggestions for improvement and

corrections if any, in this Basic Schedule of Rate of Building Works for Jaipur city are

always welcome.

I would like to convey my sincere thanks to Shri Gyan Chand Jethani

Executive Engineer, PWD Chief Engineer Office Jaipur, Shri Arun Bhardwaj,

Executive Engineer, PWD Chief Engineer Office Jaipur, Shri P.N. Maheshwari, A.En

City Circle, Jaipur and Ms Abha Gaur JEn City Circle, for their suggestions and

devotion in preparing this BSR 2016 for building works of PWD City Circle, Jaipur.

Special thanks to Er. Akhilesh Gupta present Executive Engineer Cum T.A to

S.E. PWD City Circle, for putting enormous efforts by analyzing 49 new items

including giving final shape to BSR-2016. His efforts for making the BSR-2016

available in PDF format are also appreciable.

Sd/- (Sunil Gupta)

Superintending Engineer, P.W.D. City Circle,

Jaipur

Page 3: (EFFECTIVE FROM 7 Oct., 2106)Executive Engineer, PWD Chief Engineer Office Jaipur, Shri Arun Bhardwaj, Executive Engineer, PWD Chief Engineer Office Jaipur, Shri P.N. Maheshwari, A.En
Page 4: (EFFECTIVE FROM 7 Oct., 2106)Executive Engineer, PWD Chief Engineer Office Jaipur, Shri Arun Bhardwaj, Executive Engineer, PWD Chief Engineer Office Jaipur, Shri P.N. Maheshwari, A.En
Page 5: (EFFECTIVE FROM 7 Oct., 2106)Executive Engineer, PWD Chief Engineer Office Jaipur, Shri Arun Bhardwaj, Executive Engineer, PWD Chief Engineer Office Jaipur, Shri P.N. Maheshwari, A.En

OFFICE OF THE SUPERINTENDING ENGINEER,P.W.D. CITY CIRCLE, JAIPUR

OFFICE ORDER

DATE: 14.12.2016

The additional 49 new items added in Basic Schedule of Rates 2016 (BuildingWorks), P.W.D. City Circle, Jaipur are approved by Chief Engineer (NH) videhis letter No. SEINH IBSRl45/D-1996 dated 05.12.2016 under clause 30 ofschedule of power and following 49 new items are enforced w.e.f. 1.12.2016.

1.

Supply and fixing of Modular work Station withPartition 32mm thick Aluminum top 25 mm thickparticale board with post forming three drawerpedestal unit one KBT or one CPU trolley.Size 4800 x 1500 x 1200mm single seat incombination

Unit Rate(InRs.) Remark

s.No. Item Description

Sqm 3529/- ChapterB-4 RCC

Providing and fixing of 200mm thick RCC precastpanel made of M35 grade concrete with requiredsteel, rebar chair, wire mesh, connection bolt,fastener and beveled washer with erectionreadycomplete in all respect with all lead.

2.

Providing and fixing of 150 mm thick RCC precastpanel made of M35 grade concrete with requiredsteel, rebar chair, wire mesh, connection bolt,fastener and beveled washer with erection readycomplete in all respect with all lead.

Sqm 3314/- Chapter8-4 RCC

3. Each 18843/-

ChapterB-

16AluminiumWork

4.

Supply and fixing of Modular work Station withPartition 32mm thick Aluminum top 25 mm thickparticale board with four side edage banding onedrawer and one open able shutter pedestal unitone KBT or one CPU trolley.Size 6000 x 3000 x 1200mm single seat incombination

Each 29880/-

ChapterB-16

AluminiumWork

ChapterB-16

AluminiumWork

7.

5.

Supply and fixing of Modular work Station withPartition 32mm thick Aluminum top 25 mm thickMDF board with Membrane three drawer pedestalunit one KBT or one CPU trolley.Size 4600 x 2100 x 1200mm single seat incombination

6.

Supply and fixing of Modular work Station withPartition 32mm thick Aluminum top 25 mm thickparticaleboard with post formed three drawerpedestal unit one KBT or one CPU trolley.Size 4500 x 2400 x 1200mm single seat incombination

Each 29794/-

ChapterB-16

AluminiumWork

Supply and fixing of Modular work Station withPartition 32mm thick Aluminum top 25 mm thick ChapterMDF board with Membrane three drawer pedestal B-16unit one KBT or one CPU trolley. Each 36278/- Aluminium

~~~bi~~~~n x 3000 x 1200mm ..Sin_g_le__s_e~t._in__![__ L D. Work

,~~

Each 27224/-

,j""

Page 6: (EFFECTIVE FROM 7 Oct., 2106)Executive Engineer, PWD Chief Engineer Office Jaipur, Shri Arun Bhardwaj, Executive Engineer, PWD Chief Engineer Office Jaipur, Shri P.N. Maheshwari, A.En

Supply and fixing of Modular work Station withPartition 32mm thick Aluminum top 25 mm thick Chapterparticale board with post formed one drawer or B-16

8. one open able shutter pedestal unit one KBT or Each 28336/- Aluminiumone CPU trolley. WorkSize 4500 x 3000 x 1200mm single seat incombinationSupply and fixing of Modular work Station withPartition 32mm thick Aluminum top 25 mm thick Chapter

9. particale board with post formed three drawer Each 21030/- B-16pedestal unit one KBT or one CPU trolley. AluminiumSize 3600 x 2400 x 1200mm single seat in WorkcombinationSupply and fixing of Modular work Station withPartition 32mm thick Aluminum top 25 mm thick Chapterparticale board with four side edage banding 8-1610. 1200mm height storage unit with two drawer one Each 607871- AluminiumKBT or one CPU trolley. WorkSize 1500 x 3000 x 1650mm single seat incombinationSupply and fixing of Modular work Station withPartition 32mm thick Aluminum top 25 mm thick Chapter

11. particale board with post formed three drawer one Each 10591/- B-16KBT or one CPU troliey. AluminiumSize 2100 x 2100 x 1200mm single seat in WorkcombinationSupply and fixing of Modular work Station withPartition 32mm thick Aluminum top 25 mm thick Chapterparticale board with post formed legas 18mm B-1612. particle board with four side edage banding one Each 173071- AluminiumKBT or one CPU trolley. WorkSize 2100 x 2100 x 1200mm single seat incombinationSupply and fixing of Modular work Station withPartition 60mm thick Aluminum top 25 mm thickparticale board with post formed legas 18mm Chapter

13. particle board with four side edage banding with Each 190533 B-16three drawer one KBT or one CPU trolley Two /- Aluminium1200mm height storage unit. WorkSize 6000 x 3000 x 1200mm single seat incombinationSupply and fixing of Modular work Station withPartition 22mm thick Aluminum top 25 mm thick Chapterparticale board with post formed one drawer or

14. one open able shutter one KBT or one CPU Each 22018/- B-16Aluminiumtrolley Two 1200mm height storage unit. WorkSize 3000 x 2700 x 1200mm single seat in

combinationSupply and fixing of Modular work Station withPartition 22mm thick Aluminum top 25mm thick Chapterparticale board with post formed one drawer or

15. one open able shutter one KBT or one CPU Each 18072/- B-16Aluminiumtrolley Two 1200mm height storage unit. WorkSize 2400 x 1200 x 1200mm single seat in

. combination-----~-

D~d2d ~ s

Page 7: (EFFECTIVE FROM 7 Oct., 2106)Executive Engineer, PWD Chief Engineer Office Jaipur, Shri Arun Bhardwaj, Executive Engineer, PWD Chief Engineer Office Jaipur, Shri P.N. Maheshwari, A.En

16.

Supply and fixing of Modular work Station withPartition 60mm thick Aluminum top 25mm thickparticale board with post formed one drawer orone open able shutter one KBT or one CPUtrolley Two 1200mm height storage unit.Size 1200 x 1200 x 1200mm single seat incombination

Each 21286/-

ChapterB-16

AluminiumWork

17.

Supply and fixing of Modular work Station withPartition 22mm thick Aluminum top 25mm thickparticale board with post formed one drawer orone open able shutter one KBT or one CPUtrolley Two 1200mm height storage unit.Size 2400 x 600 x 1200mm single seat incombination

Each 21690/-

ChapterB-16

AluminiumWork

Supply and fixing of Modular work Station withPartition 60mm thick Aluminum top 25mm thickparticale board with post formed one drawer orone open able shutter one KBT or one CPUtrolley Two 1200mm height storage unit.Size 1800 x 1800 x 1950mm single seat incombination

Each 75961/-

ChapterB-16

AluminiumWork

18.

19.

Cement, Concrete flooringl cement plasterl CCRoad, Plain or RCC work & water retaining worksproviding and mixing admixture of Syntheticpolypropylene Fibrillated mesh fibers free formany reprocess Olefins &comfirming to ASTM C1116 Type III 4.1.3 Having grade 6mm/12mmmelting point of 165 deg.C., strength>600 mpaSp. Gravity:0.92g/cc, diameter 10-70 microns. Itis required in specified ratio @ 0.25% (125 Gm.Fibers in 50 Kg. cement) for use. Mix it directlywith contents in rotating site mixer direction ofEngineer in charge with all leads and lifts.

Each

58/­Perpack125Gm.

ChapterB-3 CCWork

20.

Supply and installation of Multi RibProofing/cladding Sheet Manufacture out of0.50mm TCT (Total Coated Thickness) hightensile Zinc aluminum alloy coated galvaiumeseel(as per 150gsm zinc aluminum coated 550Mpatuekd strength) confirming to IS: 1397/astm A-792sheet to have wide pens 30mm high NB at 250centre and centre width of 1020mm shets becasted with regular modified plyster system On acontinuous with line on centre for face and with apolyster coating respectively sheet shall haveproportionality with siphoned plate at made at toprevent Irakage sheet shall be fixed by more ofsell drilling lift tapping hot dip zinc coated hoxhead fasterner of size 12x14x55mm long. Thesheet shall be supplied in cost one length and foea minimum up to 12mts with all scaffolding.

Sqm 626/-ChapterNew Item

21.

Supply and Installation of ROOF -PREFABRICATED INSULATED PPGL FACEPANEL:Roof: Insulated sandwich panels for roof of totalthickness mentioned below exclusive of crest

ChapterNew Item

Page 8: (EFFECTIVE FROM 7 Oct., 2106)Executive Engineer, PWD Chief Engineer Office Jaipur, Shri Arun Bhardwaj, Executive Engineer, PWD Chief Engineer Office Jaipur, Shri P.N. Maheshwari, A.En

height of top corrugation. Panel shall be made of0.50mm (+/-O.04mm) thick pre coated metalsheet on both sides .of rigid polyurethaneinsulation. The top external facing metal sheetshall have corrugated shape with crest. Thetrapezoidal shape crowns/crest height should notbe less than 30mm. The pre-coated metal sheetshall be PPGL (Pre Painted Galvalume Sheetwith AZ. coating) sheet having SOP (SuperDurable Polyester) colour coat of 1B micron (min).The bottom sheet must have tongue and groovetype flange (U shape) of Bmm x Bmm on grooveside and Bmm x 12mm on tongue side. Flangemust be on lengthwise sides for joining adjacentpanels. Panel's bottom side PPGL sheet mustalso be pre-strengthened by full lengthwisestiffening with semi-circular beading of 12mmwidth & 3 to 4mm depth at 240 (+/-5) mm pitch.The top corrugated sheet must have at-least oneopen crown/crest for overlapping adjacent panelwidthwise. Similarly the top corrugated sheetmust have suitable open extension of min 6" onbottom widthwise side of panel for overlappingfurther panels joined lengthwise also. Theinsulation core shall be self-extinguishing DIN4102,Class 83 fire retardant class rigid PUR withthermal conductivity of 0.025 W/mK and withinitial density of 40kg/m3 (+/-2kg) suitable fortemperature range of -30 degree C to +80 degreeC. The panel must be made using glue-free highpressure hot pressing self-bonding method.PPGL sheet on both sides of panel shall have amin15 micron protective plastic guard film toavoid scratches during transportation.Thickness 65mm (+/- 2mm)Thickness 105mm (+/- 2mm)

Sqm. 2292/-2593/-

22.

Supply and Installation of WALL -PREFABRICATED INSULATED PPGL PANEL:Walls: Insulated sandwich panels for wall of totalthickness mentioned below. Panel shall have0.50mm (+/-0.04mm) thick pre coated metalsheet on both sides of rigid PUR insulation. Thepre-coated metal sheet shall be PPGL (PrePainted Galvalume Sheet with AZ coating) sheet

ChapterNew Item

Page 9: (EFFECTIVE FROM 7 Oct., 2106)Executive Engineer, PWD Chief Engineer Office Jaipur, Shri Arun Bhardwaj, Executive Engineer, PWD Chief Engineer Office Jaipur, Shri P.N. Maheshwari, A.En

..

Sqm. 2109/­! 2292/-

ChapterNew Item

having SOP (Super Durable Polyester) colourcoat of 18 micron (min). The panels shall bevertically joined together with adjacent panel bytongue and groove joints. For joining, wall panel'smetal sheet facings must have lengthwise flange(U shape) of 8mm x 8mm on groove side and8mmx12mm on tongue side of panel. The pre­coated metal sheet (PPGL) must also be pre­strengthened by full lengthwise stiffening withsemi-circular beading of 12mm width & 3 to 4mmdepth at 240 (+1-5) mm pitch. Panels may haveoptional provision for inbuilt electrical conduitrunning lengthwise atvertical center of specifiedpanels. The insulation core shall be self­extinguishing DIN 4102,Class B3 fire retardantclass rigid PUR with thermal conductivity of 0.025W/mK and with density of 40kg/m3 (+1-2kg)suitable for temperature range of -30 degree C to+80 degree C. The panel must be made usingglue-free high pressure pressing self-bondingmethod. PPGL sheet on both sides of panel shallhave a min15 micron protective plastic guard filmto avoid scratches during transportation.Thickness 55mm (+1- 2mm)Thickness 65mm (+1- 2mm)

I

23.

Supplv and Installation of WALL -PREFABRICATED INSULATED CEMENT FACEPANEL:Factory-readymade structural reinforced insulatedwall panel of thickness mentioned below. Panelshall be made of 6mm (+/-0.6mm) thick asbestos­free fiber cement sheet! Cement bonded particleboard as per IS:14276:1995 on both sides of rigidPUR insulation. The wall panel shall be verticallyjoined together with adjacent panel by biscuitjoints lengthwise with suitable constructionadhesive. Joining member (biscuit) shall be madeof approx 12mm thick cement sheet ICementbonded particle board as per IS:14276:1995.Panels may have optional provision for inbuiltelectrical conduit running lengthwise at verticalcenter of specified panels. Both verticallengthwise sides of panels must have full lengthMS tubes of min 1.0mm thickness for betterstructural strenqth.The final £§I.rl_~1surface must 1 _

i l

--.~~-

Page 10: (EFFECTIVE FROM 7 Oct., 2106)Executive Engineer, PWD Chief Engineer Office Jaipur, Shri Arun Bhardwaj, Executive Engineer, PWD Chief Engineer Office Jaipur, Shri P.N. Maheshwari, A.En

SUDDlv and Installation of WALL -PREFABRICATED INSULATED LAMINATEDFACE PANEL:Factory-readymade interior wall panel ofthickness mentioned below. The panels shallhave suitable provision for joining adjacentpanels. Interior panels may have optionalprovision for inbuilt electrical conduit runninglengthwise at vertical center of specified panels.The insulation core shall be self-extinguishingDIN 4102,Class 83 fire retardant class rigid PURwith thermal conductivity of 0.025 W/mK and withdensity of 40kg/m3 (+/-2kg) suitable fortemperature range of -30 degree C to +80 degreeC. The panel must be made using glue-free highpressure hot pressing self-bonding method and

24. shall be free from major surface undulations. bothI sides of panel shall have a min15 micronprotective plastic guard film to avoid scratchesduring transportation.

1. Panel shall be made of min 4mm (+/-0.5mm) thick laminated wood basedmedium density fiber board sheet on bothsides of rigid PUR insulation.

Thickness 65mm (+/- 2mm)Thickness 75mm (+/- 2mm)

Sqm. 2292/-2410/-

Sqm. 2410/-2528/-

ChapterNew Item

be free from undulations. The Insulating coreshall be self-extinguishing DIN 4102,Class 83 fireretardant class rigid PUR with thermalconductivity of 0.025 W/mK and with density of40kglm3 (+/-2kg) suitable for temperature rangeof -30 degree C to +80 degree C. The panel mustbe made using glue-free high pressure hotpressing self-bonding method and shall be freefrom major surface undulations.Thickness 65mm (+/- 2mm)Thickness 75mm (+/- 2mm)

Supply and Installation of SMALL ROOM Chapter_ ~~~ . j (TOILET & GUARD ROOM) - j.._.__~ ..-'-- __L_.:N'7e:=..::w.:....:..:clt.=.:em~

s~

Page 11: (EFFECTIVE FROM 7 Oct., 2106)Executive Engineer, PWD Chief Engineer Office Jaipur, Shri Arun Bhardwaj, Executive Engineer, PWD Chief Engineer Office Jaipur, Shri P.N. Maheshwari, A.En

RMT 2001-

ChapterNew Item

ChapterNew Item

26. AccessoriesSupply and Installation of (Labourrate included in main item)

Flashings (inner and outer):Corner angle flashings of equal shape forcovering various corners and open sides ofpanels. Flashings shall be made from 0.5mmthick pre-coated PPGL sheet in following sizes:50mm x 50mm~ _ _L_ __

(ii)

PREFABRICATED INSULATED PPGL FACEPANEL:Insulated closed lip panels (for door, wall androof) of thickness mentioned below. Panel shallhave 0.50mm (+1-0.04mm) thick pre-coated metalsheet on both sides of rigid PUR insulation. Thepre-coated metal sheet shall be PPGL (PrePainted Galvalume Sheet with AZ. coating) sheethaving SOP (Super Durable Polyester) colourcoat of 18 micron(min). The Pre coated metalsheet on both sides must be pre-strengthened byfull lengthwise stiffening with semi-circularbeading of 12mm wide & 3mm depth at 240 (+1-5)mm pitch. Panels shall have closed lengthwisesides made by right angle flange on both side ofPre coated metal sheets, free from cap typecovers. The top and bottom part on widthwisesides of panels must have full width MS Squaretube insert of (min 25mm x 1.0mm) for betterscrew retention and strength. The insulation coreshall be self-extinguishing DIN 4102,Class 83 fireretardant class rigid PUR with thermalconductivity of 0.025 W/mK and with density of40kg/m3 (+1-2kg) suitable for temperature rangeof -30 degree C to +80 degree C. The panel mustbe made using glue-free high pressure hotpressing seff-bonding method free from majorundulations. PPGL sheet on both sides of panelshall have a min15 micron protective plasticguard film to avoid scratches duringtransportation.Thickness of 32mm (+/-2mm)Thickness of 50mm (+/-2mm)

(i)

Bottom and Top U track:U-track for mounting panels with floor. Thechannel shall be made from minimum 1.15 mmthick PPGL sheet with flange height of minimum35 mm and width as per thickness of panel used.

Sqm. 2055/-SQm. 2206/-

A.l

ChapterNew Item

Page 12: (EFFECTIVE FROM 7 Oct., 2106)Executive Engineer, PWD Chief Engineer Office Jaipur, Shri Arun Bhardwaj, Executive Engineer, PWD Chief Engineer Office Jaipur, Shri P.N. Maheshwari, A.En

100mm x 100mm RMT 150/-200/-

Roof Ridge Cae:Ridge flashlngfor roof panels shall be made from Chapter

(iii) 0.5mm thick pre-coated PPGL sheet of New Item200mm x200 mm.

RMT 200/-Roof Front Corrugated Cae:

(iv)Front side flashing for roof panels (corrugated RMT 200/- Chaptertrapazodial shape) shall be made from 0.5mm New Itemthick pre-coated PPGL sheet.Roof End Cae:

(v) RMT 150/- ChapterEnd cap for closing ends of roof panels made New Itemfrom 0.5mm thick PPGL sheet.Frame for DoorlWindow: Chapter

(vi) Frame shall be made out of min 1.15mm thick RMT 200/-press steel sheet.

New Item

Panel End Caes:

(vii)U or L shape caps suitable for thickness of panel RMT 100/- Chapterused, with 30mm flange. It should be made frem New Item0.5mm Pre coated PPGL sheet.Self Drilling Screws:

(viii) 5" Each 12/- Chapter3.5" 9/- New Item1" 5/-

(ix) Adhesives KG. 1801- ChapterNew Item

Supply and fixing of Cement Bonded ParticleBoard (as per IS 14276) false ceiling using 6MMthick Cement Board with galvanized and prepainted steel T section of size 24mm x 27mmx O.4mm for main T duty pre punched toaccept cross T section of size 24mm x25mm x O.4mm duly punched at both ends for

27 insertion into main T. The grid size will be Sqm 594/- Chapter610mm x 610mm. The frame work (grid) is New Itemsuspended to the roof by using G.I flat of I

0.60mm or 14-gauge G.I wire with necessaryfixers to the roof and frame work. Cement Boardpanel is laded on the grid. The cost inclusive ofnecessary hardware, labor, one coat of primer I(Both side) and two coats of smooth finish on

I

visible side.Supply and fixing of Cement Bonded ParticleBoard (as per 14276) wall paneling using 10MM thick Cement Board with frame work madeof GI stud section of size 48mm x 35mm x0.55mm thick placed at every 610 mm CIC Chapter

28 intervals vertically and at 1200mm internals 1526/-horizontally fixed to the wall by means of self Sqm New Items

expansion screws and caps. Cement Board panelis to be fixed to frame by means of self tapingscrews placed at every 300 mm intervals leaving3mm gap between two panels. The cost inclusive -_.

Page 13: (EFFECTIVE FROM 7 Oct., 2106)Executive Engineer, PWD Chief Engineer Office Jaipur, Shri Arun Bhardwaj, Executive Engineer, PWD Chief Engineer Office Jaipur, Shri P.N. Maheshwari, A.En

of one coat of Altek primer and two coats of Alteksmooth finish and cost & conveyance of allmaterials, labor charges etc. complete as per thedirection of Engineer in charge.Supply and fixing of Cement Bonded ParticleBoard (as per 14276) double skin partitionusing with 10 MM thick Cement Board made outof G.I. track section of size 50mmx 35mm x 0.55mm for fixing to the roof and floor and stud. ~.l:»1::....UVII VI l:»ILI:: ....0111111 X .lomm x u.oornrnplaced in track section vertically at 610mmintervals and at 1200mm intervals horizontallyfixed to the wall by means of self expansionscrews and caps to the wall and roof. Cement SqmBoard panel is to be fixed both sides of framework by using self taping screws fixed atevery 300mm intervals to the frame workleaving 3 mm gap between two panels. The costinclusive with one coat of Alltek primer and twocoats of Alltek smooth finish and cost andconveyance of all materials to site, labor chargesetc., complete as per the direction of Engineer incharae.

ChapterNew Item220829

Supply and fixing of Factory LaminatedCement Bonded Particle Board do ubi e skinpartition using with 10MM FactoryLaminated Cement Bonded Board madeout of G.I track section of size SOmm x 35mm x0.S5mm for fixing to the roof and floor and studsection of size 48mm x 35mm x O.SSmmplacedin track section vertically at 610mm intervals andat 1200mm internals horizontally. The frame is Sqmfixed by means of self expansion screws andcaps to the wall / roof. Laminated CementBonded Particle Board is to be fixed both sides ofthe frame work by using 2mm thick electro platedCR flat section leaving 3mm gap between twopanels. The cost inclusive of cost andconveyance of all materials to sites, othermaterials incidentals and labor charges as perthe direction of Engineer in charges.

ChapterNew Item3092/-30

Supply and fixing of Bath room / Toilet doorshutter with 16mm Factory Laminated CementBonded Particle Board BISON Lam (IS 14276)door shutter with all-round 'U' lipping of PPSsection of size 12mm X 18mmX 12mmXO.6mmthickness with a hardware of 12mm dia X200mmlong aluminum aldrop - 2 nos2 No of 12Smm Sqmlong handles and also 3 no Of IS304 gradePatee Hinges 3mmX12mmX180mm long withpole receiver of 10mm dia pole X40mm longwelded on 2mm X40mm(ss304) plates works asreceiver for RT patte hinges. The price inclusiveof all material at site.

ChapterNew Item2188/-31.

Solid Rectanaular Block (400x200x200 400x200x10032 400x200x150

Page 14: (EFFECTIVE FROM 7 Oct., 2106)Executive Engineer, PWD Chief Engineer Office Jaipur, Shri Arun Bhardwaj, Executive Engineer, PWD Chief Engineer Office Jaipur, Shri P.N. Maheshwari, A.En

225x200x100)Providing and fixing up to floor five level ofcement concrete solid blocks (M-20 Grade) ofdifferent sizes (Manufactured with fullymechanised dry cast process with forced actionmixer whose arms revolve along the main axisand rotate about its own axis also, havinghumidity sensor for moisture control ofwlc ratio inconcrete mix. Manufactured with steel moulds(Milled and manufactured in CSI diamond or CSINitro process for accuracy) on steel base plate of Cummin 16 mm thick; Having Vibration and pressingaction both together with the help ofmutiplesynchronised vibrators. Power ofhydraulic station should be minimum 50KW forcompaction and cured in controlled chambershaving humidity control and automated aircirculation system) including hoisting and settingin position with cement mortar 1:3 (1 Cement: 3Coarse Sand), cost of required centering,shuttering complete.

33 Hollow Rectanaular Block (400x200x200 400x200x100)

Cum

ChapterNew Item9370/-

Providing and fixing up to floor five level ofcement concrete Hollow Rectangular blocks ofdifferent sizes (Manufactured with fullymechanised dry cast process with forced actionmixer whose arms revolve along the main axisand rotate about its own axis also, havinghumidity sensor for moisture control of wlc ratio inconcrete mix. Manufactured with steel moulds(Milled and manufactured in CSI diamond or CSINitro process for accuracy) on steel base plate ofmin 16 mm thick; Having Vibration and pressingaction both together with the help ofmutiplesynchronised vibrators. Power ofhydraulic station should be minimum 50KW forcompaction and cured in controlled chambershaving humidity control and automated aircirculation system) including hoisting and settingin position with cement mortar 1:3 (1 Cement: 3Coarse Sand), cost of required centering,

r--,-----j-s_h_utteringcomple~ __ ~.._ _ - ,~.-=-=--::---,-L----.J----__jL-----~

34 Insulated Rectangular Block (400x200x200 rnm)

ChapterNew Item

Providing and fixing up to floor five level ofcement concrete insulated blocks of differentsizes having a layer of polysterene as insulatingmaterial (Manufacturedwith fully mechanised drycast processwith forced action mixer whose armsrevolve along the main axis and rotate about itsown axis also, having humidity sensor formoisture control of wlc ratio in concrete mix.Manufactured with steel moulds (Milled andmanufactured in CSI diamond or CSI Nitroprocess for accuracy) on steel base plate of min

C____ _j__1_6_m__ITl__thicls___!:!C3\1!n...9.Vibration and pressing

Cum

6675/-

99201- ChapterNew Item

"

Page 15: (EFFECTIVE FROM 7 Oct., 2106)Executive Engineer, PWD Chief Engineer Office Jaipur, Shri Arun Bhardwaj, Executive Engineer, PWD Chief Engineer Office Jaipur, Shri P.N. Maheshwari, A.En

action both together with the help ofmutiplesynchronised vibrators. Power ofhydraulic station should be minimum 50KW forcompaction and cured in controlled chambershaving humidity control and automated aircirculation system) including hoisting and settingin position with cement mortar 1:3 (1 Cement: 3Coarse Sand) including cost of requiredcentering, shuttering complete.

35 Interlockina Paver Blocks havina 80 mm thickness in M-40 arade concreteProviding and Laying 80 mm thick cementconcrete blocks of M-40 Grade (Manufacturedwith fully mechanised dry cast process withforced action mixer whose arms revolve along themain axis and rotate about its own axis also,having humidity sensor for moisture control of wlcratio in concrete mix. Manufactured with steelmoulds(Milied and manufactured in CSI diamondor CSI Nitro process for accuracy) on steel baseplate of min 16 mm thick; Having Vibration andpressing action both together with the help of Sqm.mutiplesynchronised vibrators. Power ofhydraulic station should be minimum 50KW forcompaction and cured in controlled chambershaving humidity control and automated aircirculation system} spreading 25mm thick sandunderneath and filling joints with sand on existingW.B.M.base, as per IS15658:2006 and allmaterials shall conform to MoRTH SpecificationClause 602.

1100/- ChapterNew Item

36 Interlockina Paver Blocks havina 100 mm thickness in M-50 arade concreteProviding and Laying 100 mm thick cementconcrete blocks of M-50 Grade(Manufacturedwith fully mechanised dry cast process withforced action mixer whose arms revolve along themain axis and rotate about its own axis also,having humidity sensor for moisture control of wlcratio in concrete mix. Manufactured with steelmoulds (Milled and manufactured in CSI diamondor CSI Nitro process for accuracy) on steel baseplate of min 16 mm thick; Having Vibration andpressinq action both together with the help ofmutiplesynchronised vibrators. Power ofhydraulic station should be minimum 50KW forcompaction and cured in controlled chambershaving humidity control and automated aircirculation system} spreading 25mm thick sandunderneath and filling joints with sand on existingW.B.M.base, as per IS15658:2006 and allmaterials shall conform to MoRTH SpecificationClause 602.

Sqm. 1289/- ChapterNew Item

37 Interlockina Paver Blocks havina 120 mm thickness in M-50 arade concrete

IProviding and Laying 120 mm thick cementconcrete blocks of M-50 Grade(Manufactured Sqm 1424/- Chapter

New Item[-""itD_ fu!ly' mechanised dry _-=c-=a-=-st::_____rp::_:_r-=-o-=-ce::..:s:..:s:____:w..:..:i-=th_:__j__[_ L__~ __ __j

~

Page 16: (EFFECTIVE FROM 7 Oct., 2106)Executive Engineer, PWD Chief Engineer Office Jaipur, Shri Arun Bhardwaj, Executive Engineer, PWD Chief Engineer Office Jaipur, Shri P.N. Maheshwari, A.En

forced action mixer whose arms revolve along themain axis and rotate about its own axis also,having humidity sensor for moisture control of wlcratio in concrete mix.. Manufactured with steelmoulds (Milled and manufactured in CSI diamondor CSI Nitro process for accuracy)on steel baseplate of min 16 mm thick; Having Vibration andpressing action both together with the help ofmutiplesynchronised vibrators. Power ofhydraulic station should be minimum 50KW forcompaction and cured in controlled chambershaving humidity control and automated aircirculation system) spreading 25mm thick sandunderneath and filling joints with sand on existingW.B.M.base, as per IS15658:2006 and allmaterials shall conform to MoRTH SpecificationClause 602.

38 Interlockina Paver Blocks havina 100mm thickness in M-55 arade concreteProviding and Laying 100 mm thick cementconcrete blocks of M-55 Grade (Manufacturedwith fully mechanised dry cast process withforced action mixer whose arms revolve along themain axis and rotate about its own axis also,having humidity sensor for moisture control of wlcratio in concrete mix. Manufactured with steelmoulds (Milled and manufactured in CSI diamondor CSI Nitro process for accuracy)on steel baseplate of min 16 mm thick; Having Vibration and Sqmpressing action both together with the help ofmutiplesynchronised vibrators. Power ofhydraulic station should be minimum 50KW forcompaction and cured in controlled chambershaving humidity control and automated aircirculation system) spreading 25mm thick sandunderneath and filling joints with sand on existingW.B.M.base, as per IS15658:2006 and allmaterials shall conform to MoRTH SpecificationClause 602.

13891- ChapterNew Item

39 Interlockina Paver Blocks havina 120 mm thickness in M-55 arade concrete

14891- ChapterNew Item

Providing and Laying 120 mm thick cementconcrete blocks of M-55 Grade (Manufacturedwith fully mechanised dry cast process withforced action mixer whose arms revolve along themain axis and rotate about its own axis also,having humidity sensor for moisture control of wlcratio in concrete mix. Manufactured with steelmoulds (Milled and manufactured in CSI diamondor CSI Nitro process for accuracy) on steel base Sqm.plate of min 16 mm thick; Having Vibration andpressing action both together with the help ofmutiplesynchronised vibrators. Power ofhydraulic station should be minimum 50KW forcompaction and cured in controlled chambershaving humidity control and automated aircirculation system) spreading 25mm thick sand

Page 17: (EFFECTIVE FROM 7 Oct., 2106)Executive Engineer, PWD Chief Engineer Office Jaipur, Shri Arun Bhardwaj, Executive Engineer, PWD Chief Engineer Office Jaipur, Shri P.N. Maheshwari, A.En

underneath and filling joints with sand on existingW.B.M.base, as per IS15658:2006 and allmaterials shall conform to MoRTH SpecificationClause 602.

40Kerb Stones of 1200x300x150. 1000x450x150. 1000x600x150. 600x300x150size IM-30}

..•

Providing .and Laying cement concrete KerbStones ·of different sizes .in M-30 grade(Manufactured with fully mechanised dry· castprocess with forced action mixer whose armsrevolve along the main axis and rotate about itsown axis also, having humidity sensor formoisture control of wlc ratio in concrete mix.Manufactured with steel moulds (Milled andmanufactured in CSI diamond or CSI Nitroprocess for accuracy) on steel base plate of min Cum16 mm thick; Having Vibration and pressingaction both together with the help ofmutiplesynchronised vibrators. Power ofhydraulic station should be minimum 50KW forcompaction and cured in controlled chambershaving humidity control and automated aircirculation system) in position to the required line,level and curvature jointed with cement mortar1:3 (1 Cement: 3 Coarse sand) including makingof joints, drainage opening wherever required.

8572/- ChapterNew Item

41Kerb Stones of 1200x300x150. 1000x400x150.1000x600x150.600x300x150size (M-40)Providing and Laying cement concrete KerbStones of different sizes in M-40 grade(Manufactured with fully mechanised dry castprocess with forced action mixer whose armsrevolve along the main axis and rotate about itsown axis also, having humidity sensor formoisture control of wlc ratio in concrete mix.Manufactured with steel moulds (Milled andmanufactured in CSI diamond or CSI Nitroprocess for accuracy) on steel base plate of min Cum16 mm thick; Having Vibration and pressingaction both together with the help ofmutiplesynchronised vibrators. Power ofhydraulic station should be minimum 50KW forcompaction and cured in controlled chambershaving humidity control and automated aircirculation system) in position to the required line,level and curvature jointed with cement mortar1:3 (1 Cement: 3 Coarse sand) including makingof joints dralnaoe oneninu wherever required.

9067/- ChapterNew Item

r---:4::.:2:_~C~e:.:I:.:.::lu~l?ar:..C=o.:.:.nc~r::::e~te=-=B~lo~c~k~f.:::::o.:..r.:..P.:.::it:;::ch::.:i~n~oa::.:n~d~a:l.l:ia:.:.;rd~e=.:nT-~Dat~h!.:::s:.JI~6~OO~x~4~O~O~x~80~))wi!!n~M2.:-~3~O_..~Providing and fixing Cellular concrete blocks (M-30 Grade), 600x400x80 mm sizes (Manufacturedwith fully mechanised dry cast process withforced action mixer whose arms revolve along the Sqm.main axis and rotate about its own axis also, )having humidity sensor for moisture control of w/£ _~__ . ..~ ~_. __

739/- ChapterNew Item

Page 18: (EFFECTIVE FROM 7 Oct., 2106)Executive Engineer, PWD Chief Engineer Office Jaipur, Shri Arun Bhardwaj, Executive Engineer, PWD Chief Engineer Office Jaipur, Shri P.N. Maheshwari, A.En

ratio in concrete mix. Manufactured with steelmoulds (Milled and manufactured in CSI diamondor CSI Nitro process for accuracy) on steel baseplate of min 16 mm thick; Having Vibration andpressing action both together with the help ofmutiplesynchronised vibrators. Power ofhydraulic station should be minimum 50KW forcompaction and cured in controlled chambershaving ~umidity control and automated aircirculation system) including hoisting and settingin position with cement mortar 1:3 (1 Cement: 3Coarse Sand), cost of required centering,shuttering complete.

43 Pre Cast Concrete Flooring(Slab 600x600x100. 1000x650x100}

44 Pre Cast U/Semi circular Drains (Outer size 600x400 mm, wall thickness 80mmi

ChapterNew Item

Providing and fixing Precast concrete flooringslabs (M-30 Grade) of differentsizes(Manufactured with fully mechanised drycast process with forced action mixer whose armsrevolve along the main axis and rotate about itsown axis also, having humidity sensor formoisture control of wlc ratio in concrete mix.Manufactured with steel moulds (Milled andmanufactured in CSI diamond or CSI Nitroprocess for accuracy) on steel base plate of min16 mm thick; Having Vibration and pressing Sqm. 894/-action both together with the help ofmutiplesynchronised vibrators. Power ofhydraulic station should be minimum 50KW forcompaction and cured in controlled chambershaving humidity control and automated aircirculation system) including hoisting and settingin position with cement mortar 1:3 (1 Cement: 3Coarse Sand), cost of required centering,shuttering complete and spreading 25mm thicksand underneath.

Providing and fixing Precast concreteUdrains (M-30 Grade) of different sizes (Manufactured withfully mechanised dry cast process with forcedaction mixer whose arms revolve along the mainaxis and rotate about its own axis also, havinghumidity sensor for moisture control of wlc ratio inconcrete mix. Manufactured with Steel moulds(Milled and manufactured in CSI diamond or CSINitro process for accuracy) on steel base plate ofmin 16 mm thick; Having Vibration and pressing R.M.action both together with the help ofmutiplesynchronised vibrators. Power ofhydraulic station should be minimum 50KW forcompaction and cured in controlled chambershaving humidity control and automated aircirculation system) including hoisting and settingin position with cement mortar 1:3 (1 Cement : 3Coarse Sand), cost Q_f r~quired centeril'1_9_, _

--~~~)-

4171- ChapterNew Item

Page 19: (EFFECTIVE FROM 7 Oct., 2106)Executive Engineer, PWD Chief Engineer Office Jaipur, Shri Arun Bhardwaj, Executive Engineer, PWD Chief Engineer Office Jaipur, Shri P.N. Maheshwari, A.En

shuttering complete and spreading 25mm thicksand underneath.Providing, hoisting and fixing up to floor five levelprecast reinforced concrete work in Nominal M20grade mix including cost of required centering,

45 shuttering, finishing, smooth with 6 mm thickcement plaster 1:3 (1 cement: 3 fine sand) onexposed surface complete excluding cost ofreinforcementBeams. Columns. slabs, Shelves, Vertical & Correctionhorizontal fins individually or forming box louvers Already insetting in cement mortar 1:2 (1 cement: 2 sand) Cum in BSR nominiclatuor grouts as l2er reguirements no re to

change Chapter4.16.5

Providing and fixing 1st quality standard white,grey, ivory, fume red brown, light green, light blueand other light shades ceramic glazed vitrifiedtiles with water absortion less than or equal to0.08% confirming to IS:13753 & IS: 15622 of size600mm x 600 mm , 800mm x 800mm, 600mm x

46. 1200mm, 800mm x 1200mm, 196mmx1215mm,1000mm x 2000mm, in floors,steps etc. laid on a bed of neat cement slurryfinished with flush pointing in the white cementmixed with pigment to match the shade of the tile Chaptercomplete (excluding the cost of cement plaster on B-7 Tileswalls and pillar). Work

(i) Size 600mm x 600mm Sqm 1098/-(iT) Size 800mm x 800mm Sqm 1150/-(iii) Size 600mm x 1200mm Sqm 1330/-(iv) Size 800mm x 1200mm Sqm 1659/-(V) Size 196mm x 1215mm Sqm 1658/-

lliL Size 1OOOmmx 2000mm Sqrn 3447/-Providing and fixing 1st quality MAT & GLOSSYfinished ceremic tile size 300x600 mm, 250x1000mm, 300x450mm, 250 x 375mm, 200 x 600mm

. confirming to IS : 13755 and IS : 15622 coloursuch as white, grey, ivory, fume red brown, light

47. green, light blue and other light shades in floors,steps, pillars etc. laid on a bed of neat cement Chapterslurry finished with flush pointing in the whitecement mixed with pigment to match the shade of B-7 Tiles

the tile complete (including the cost of cement Work

mortar bed 1:4).(i) Size 250mm x 375mm Sqrn 661/-(iO Size 300mm x 450mm Sqm 735/-(iii) Size 200mm x 600mm Sqm 783/-(iv) Size 300mm x 600mm Sqm 813/-(v) Size 250mm x 1000mm Sqrn 981/-

P & F 1st qualityVitrified Polished tiles on floor,skirting and steps etc.in different sizes (thickness Chapter

48. minimum 1Omm)with water absortion less than or B-7 Tilesequal to 0.08% and conforming to IS 15622 of Work

L.___~r ~p_provedmake L~~colour and shade, lai_dwith

f~ IS;; l6~

Page 20: (EFFECTIVE FROM 7 Oct., 2106)Executive Engineer, PWD Chief Engineer Office Jaipur, Shri Arun Bhardwaj, Executive Engineer, PWD Chief Engineer Office Jaipur, Shri P.N. Maheshwari, A.En

-------------

20 mm thick CM 1:4 includinggrountingthe jointswith white cement and matching pigment etccomplete.m Size800mmx 800mm Sqm 1045/-

(ii) Size800mmx 1200mm SQm 1150/-P & F 1st qualityHeavy Duty Vitrified PolishedDigital tiles on floor, skirting and steps etc.indifferent sizes (thickness minimum 10mm) with

49. water absortion less than ~r equal 0.08% and Chapterconformingto IS 15622of approvedmake in all 8-7 Tilescolour and shade, laidwith 20 mm thick CM 1: 4 Workincluding grounting the joints with white cementand rnatchlnq piqment etc complete.

(i) Size298mmx 298mm SQm 641/-

Although every care has been taken in preparation of this BSR even then it isenjoined upon all the concerned to please point out the errors and omission ifany, observed in this BSR.

SE(City)

I::';

Page 21: (EFFECTIVE FROM 7 Oct., 2106)Executive Engineer, PWD Chief Engineer Office Jaipur, Shri Arun Bhardwaj, Executive Engineer, PWD Chief Engineer Office Jaipur, Shri P.N. Maheshwari, A.En

OF'FICE OF THE CHIEF ENGINEER (NH), PWD, RAJASTHAN, JAIPURNo. SE(NH)/BSR/4SID- /996 . Date: .sj1.y,2016

Superintending EngineerP\VD City Circle Jaipur.

Sub: - Introducing 49 new items in Building BSR 2016 ofPWD CityCircle Jaipur,

Sir,As per the recommendation of BSR Committee, approval of draft

Introducing 49 new items in Building BSR 2016 of PWP City Circle Jaipur,

~e.f. From 01.12.2016 is hereby approved during the meeting held on

30.11.2016. Concerned SE is directed to submit two copy of printed BSR to this

office at the earliest for record. It is also directed to provide a soft copy of so

compiled Building BSR-2016 in PDF format to this office for record. The new

introducing 49 new items in Building BSR 2016 will not affect past contractsIAgreements.

Pointing out errors, omissionsl alteration and suggestions if any will be .welcomed.

Yours faithfully,

Copy to:-1. PS to Hon'ble PWM Government of Rajasthan.2. PS to Addl. Chief Secretary PWD Govt. of Rajasthan Bikaner.3. PS to Secretary PWD Govr. of Rajasthan Jaipur.4. PS to CE (Road) & AS, PWD Rajasthan Jaipur.5. Chief Engineer PWD, PMGSY/SSlBuilding/QC Rajasthan Jaipur.6. MD, RSRDCC, Jhalana Doogari, Jaipur.

=J-J(Anil Kumar Garg)

Chief Engineer (NH)

Com.llD:ILF.TTER S!=(Nli)ILctte,He.J f;n~lishNew 2013-I~.Joc.51