EETPL GOLIATH

download EETPL GOLIATH

of 4

Transcript of EETPL GOLIATH

  • 8/3/2019 EETPL GOLIATH

    1/4

    PLOT NO: 1205 / A, NAYAPALLI,

    BHUBANESWAR - 751012

    TEL: 0674 2560284, CELL: 94371 32223

    1

    1 Name of Occupier of Factory

    2 Address of the factory:

    3 Distinguishing number or mark, if any,

    and description sufficient to identify

    the lifting machine, chain, rope or thelifting tackle:

    4 Design and construction: Are all the

    Mr. B. K. Dash

    H.O.T Single Girder Goliath Crane,

    Id. No: GOLIATH/CRANE/5T/EETPL-01

    Make: EETPL,

    Capacity: 5T,

    Span: 15mtrs,

    Height of Lift: 4.5mtrs

    Mfg Sl. No: Not Available

    Location : EETPL FACTORY

    PREMISES

    Yes

    M/s East End Technologies Pvt. Ltd.

    Plot No:133-137

    IDCO Indl. Estate,

    Choudwar, Cuttack.

    as per FORM 7 - A

    [As Prescribed under Rule 55-C , Sub-section (2) of Section 29, Factory Rules, 1950]

    Parthasarathi Dalai,B. Tech (Hons)COMPETANT PERSON Under Section 2 (ca) of the Factories Act. 1948 RECOGNITION NO: CP (O) NO 55 (G)

    No: LTC / PSD / 2010 / EETPL / C.P / TC / 01.10.2010

    Report of periodic examination of lifting machines, chains,

    ropes and lifting tackles

    parts of hoist or lift of good

    mechanical construction, sound material

    and adequate strength ( so far as

    ascertainable ?

    5 Date when the lifting machine, chaain,rope or lifting tackle was first taken

    into use in the factory:

    6 Date of construction or reconstruction

    (if ascertained)

    7 Date and number of certificate relating

    to any test and examination made under

    Rules 55-A and 55-G together with the

    name and address of the person who

    issued the certificate:

    8 Date of each periodical thorough

    examination made under Rule 55-F and the

    name of examiner:

    9 Date of annealing or other heat

    treatment of the chain and other lifting

    tackle made under Rule 55-E and by whom

    it was carried out:

    10 Particulars of any defects affecting the

    safe working load found at any such

    thorough examination or after annealing

    and of the steps taken to remedy such

    defects:

    11 Visual Inspection (for Maintenance):

    Not any

    Nothing observed

    Are the following parts of the hoists or lift properly maintained and in good

    working order? If not state what defects have been found.

    2009

    Year of manufacture: 2009

    Not any

    Not any

  • 8/3/2019 EETPL GOLIATH

    2/4

    (a) Encloser of Hoistway or Liftway

    (b) Landing gates and cage gates(s)

    (c) Interlocks and the landing gates and

    cage - gate(s)

    (d) Other gate fastenings

    (e) Cage and platform and fitting, guides

    and buffers, interiors of the hoistway

    or liftway

    (f) Overrunning devices

    (g) Suspension ropes or chains and their

    attatchments

    (h) Safety gear, I.e., arrangement for

    preventing fall of platform or cage

    brakes

    (i) Brakes

    (j) Worm or spur gearing

    (k) Other electrical equipment

    (l) Other parts

    12 What parts (if any) were inaccessible

    13 Repairs, renwal or alteration (if any)

    required and the period within which

    they should be executed.

    14 Load Testing:

    (a) Static tests 6.25T held at a height of 0.1mtr

    above ground for 10min

    NA

    Good condition

    NA

    Good condition

    All areas accessible

    Not necessary

    NA

    NA

    NA

    NA

    Good condition

    NA

    NA

    NA

    (b) Dynamic tests

    (c) Stability tests

    15 Maximum safe working load subject to

    repairs, renewals or alterations (if

    any) specified in item 5

    16 Others

    Signature:

    Qualification:

    Address:

    Date:

    Competant Person Regn no: CP(O)NO 55(G)

    Plot No: 1205/A, P.O: Nayapalli, Bhubaneswar - 751012.

    01.10.2010

    -

    I certify that on 01.10.2010, the above HOT GOLIATH CRANE was thoroughly cleaned to the extent

    possible and made accessible for through examination and for such tests as were necessary to

    ascertain the health of the above HOT GOLIATH CRANE. I have thoroughly examined this HOT

    GOLIATH CRANE and that the above is a correct report of the result.

    B.Tech (Hons).

    5.5T lifted upto 5.5 mtr and lowered

    Deflection at 5T:10mm at centre spanMovement in Long travel, with 5.5T

    load were found satifactory and

    stable. No overturning tendencies

    were observed.

    Below 5T.

  • 8/3/2019 EETPL GOLIATH

    3/4

    PLOT NO: 1205 / A, NAYAPALLI,

    BHUBANESWAR - 751012

    TEL: 0674 2560284, CELL: 94371 32223

    2

    1 Name of Occupier of Factory

    2 Address of the factory:

    3 Distinguishing number or mark, if any,

    and description sufficient to identify

    the lifting machine, chain, rope or thelifting tackle:

    4 Design and construction: Are all the

    Parthasarathi Dalai,B. Tech (Hons)COMPETANT PERSON Under Section 2 (ca) of the Factories Act. 1948 RECOGNITION NO: CP (O) NO 55 (G)

    No: LTC / PSD / 2010 / EETPL / C.P / TC /

    Report of periodic examination of lifting machines, chains,

    ropes and lifting tackles

    as per FORM 7 - A

    [As Prescribed under Rule 55-C , Sub-section (2) of Section 29, Factory Rules, 1950]

    01.10.2010

    Mr. B. K. Dash

    M/s East End Technologies Pvt. Ltd.

    Plot No:133-137

    IDCO Indl. Estate,

    Choudwar, Cuttack.

    H.O.T Single Girder Goliath Crane,

    Id. No: GOLIATH/CRANE/5T/EETPL-02

    Make: EETPL,

    Capacity: 5T,

    Span: 4mtrs,

    Height of Lift: 3mtrs

    Mfg Sl. No: Not Available

    Location : EETPL FACTORY

    PREMISES

    Yesparts of hoist or lift of good

    mechanical construction, sound material

    and adequate strength ( so far as

    ascertainable ?

    5 Date when the lifting machine, chaain,rope or lifting tackle was first taken

    into use in the factory:

    6 Date of construction or reconstruction

    (if ascertained)

    7 Date and number of certificate relating

    to any test and examination made under

    Rules 55-A and 55-G together with the

    name and address of the person who

    issued the certificate:

    8 Date of each periodical thorough

    examination made under Rule 55-F and the

    name of examiner:

    9 Date of annealing or other heat

    treatment of the chain and other lifting

    tackle made under Rule 55-E and by whom

    it was carried out:

    10 Particulars of any defects affecting the

    safe working load found at any such

    thorough examination or after annealing

    and of the steps taken to remedy such

    defects:

    11 Visual Inspection (for Maintenance):

    2009

    Year of manufacture: 2009

    Not any

    Not any

    Not any

    Nothing observed

    Are the following parts of the hoists or lift properly maintained and in good

    working order? If not state what defects have been found.

  • 8/3/2019 EETPL GOLIATH

    4/4

    (a) Encloser of Hoistway or Liftway

    (b) Landing gates and cage gates(s)

    (c) Interlocks and the landing gates and

    cage - gate(s)

    (d) Other gate fastenings

    (e) Cage and platform and fitting, guides

    and buffers, interiors of the hoistway

    or liftway

    (f) Overrunning devices

    (g) Suspension ropes or chains and their

    attatchments

    (h) Safety gear, I.e., arrangement for

    preventing fall of platform or cage

    brakes

    (i) Brakes

    (j) Worm or spur gearing

    (k) Other electrical equipment

    (l) Other parts

    12 What parts (if any) were inaccessible

    13 Repairs, renwal or alteration (if any)

    required and the period within which

    they should be executed.

    14 Load Testing:

    (a) Static tests

    Good condition

    NA

    Good condition

    All areas accessible

    Not necessary

    6.25T held at a height of 0.1mtr

    above ground for 10min

    NA

    NA

    NA

    Good condition

    NA

    NA

    NA

    NA

    NA

    (b) Dynamic tests

    (c) Stability tests

    15 Maximum safe working load subject to

    repairs, renewals or alterations (if

    any) specified in item 5

    16 Others

    Signature:

    Qualification:

    Address:

    Date:

    Plot No: 1205/A, P.O: Nayapalli, Bhubaneswar - 751012.

    01.10.2010

    I certify that on 01.10.2010, the above HOT GOLIATH CRANE was thoroughly cleaned to the extent

    possible and made accessible for through examination and for such tests as were necessary to

    ascertain the health of the above HOT GOLIATH CRANE. I have thoroughly examined this HOT

    GOLIATH CRANE and that the above is a correct report of the result.

    B.Tech (Hons).

    Competant Person Regn no: CP(O)NO 55(G)

    5.5T lifted upto 5.5 mtr and lowered

    Deflection at 5T:10mm at centre spanMovement in Long travel, with 5.5T

    load were found satifactory and

    stable. No overturning tendencies

    were observed.

    Below 5T.

    -