EETPL GOLIATH
-
Upload
lulendu-bhusan-rautaray -
Category
Documents
-
view
214 -
download
0
Transcript of EETPL GOLIATH
-
8/3/2019 EETPL GOLIATH
1/4
PLOT NO: 1205 / A, NAYAPALLI,
BHUBANESWAR - 751012
TEL: 0674 2560284, CELL: 94371 32223
1
1 Name of Occupier of Factory
2 Address of the factory:
3 Distinguishing number or mark, if any,
and description sufficient to identify
the lifting machine, chain, rope or thelifting tackle:
4 Design and construction: Are all the
Mr. B. K. Dash
H.O.T Single Girder Goliath Crane,
Id. No: GOLIATH/CRANE/5T/EETPL-01
Make: EETPL,
Capacity: 5T,
Span: 15mtrs,
Height of Lift: 4.5mtrs
Mfg Sl. No: Not Available
Location : EETPL FACTORY
PREMISES
Yes
M/s East End Technologies Pvt. Ltd.
Plot No:133-137
IDCO Indl. Estate,
Choudwar, Cuttack.
as per FORM 7 - A
[As Prescribed under Rule 55-C , Sub-section (2) of Section 29, Factory Rules, 1950]
Parthasarathi Dalai,B. Tech (Hons)COMPETANT PERSON Under Section 2 (ca) of the Factories Act. 1948 RECOGNITION NO: CP (O) NO 55 (G)
No: LTC / PSD / 2010 / EETPL / C.P / TC / 01.10.2010
Report of periodic examination of lifting machines, chains,
ropes and lifting tackles
parts of hoist or lift of good
mechanical construction, sound material
and adequate strength ( so far as
ascertainable ?
5 Date when the lifting machine, chaain,rope or lifting tackle was first taken
into use in the factory:
6 Date of construction or reconstruction
(if ascertained)
7 Date and number of certificate relating
to any test and examination made under
Rules 55-A and 55-G together with the
name and address of the person who
issued the certificate:
8 Date of each periodical thorough
examination made under Rule 55-F and the
name of examiner:
9 Date of annealing or other heat
treatment of the chain and other lifting
tackle made under Rule 55-E and by whom
it was carried out:
10 Particulars of any defects affecting the
safe working load found at any such
thorough examination or after annealing
and of the steps taken to remedy such
defects:
11 Visual Inspection (for Maintenance):
Not any
Nothing observed
Are the following parts of the hoists or lift properly maintained and in good
working order? If not state what defects have been found.
2009
Year of manufacture: 2009
Not any
Not any
-
8/3/2019 EETPL GOLIATH
2/4
(a) Encloser of Hoistway or Liftway
(b) Landing gates and cage gates(s)
(c) Interlocks and the landing gates and
cage - gate(s)
(d) Other gate fastenings
(e) Cage and platform and fitting, guides
and buffers, interiors of the hoistway
or liftway
(f) Overrunning devices
(g) Suspension ropes or chains and their
attatchments
(h) Safety gear, I.e., arrangement for
preventing fall of platform or cage
brakes
(i) Brakes
(j) Worm or spur gearing
(k) Other electrical equipment
(l) Other parts
12 What parts (if any) were inaccessible
13 Repairs, renwal or alteration (if any)
required and the period within which
they should be executed.
14 Load Testing:
(a) Static tests 6.25T held at a height of 0.1mtr
above ground for 10min
NA
Good condition
NA
Good condition
All areas accessible
Not necessary
NA
NA
NA
NA
Good condition
NA
NA
NA
(b) Dynamic tests
(c) Stability tests
15 Maximum safe working load subject to
repairs, renewals or alterations (if
any) specified in item 5
16 Others
Signature:
Qualification:
Address:
Date:
Competant Person Regn no: CP(O)NO 55(G)
Plot No: 1205/A, P.O: Nayapalli, Bhubaneswar - 751012.
01.10.2010
-
I certify that on 01.10.2010, the above HOT GOLIATH CRANE was thoroughly cleaned to the extent
possible and made accessible for through examination and for such tests as were necessary to
ascertain the health of the above HOT GOLIATH CRANE. I have thoroughly examined this HOT
GOLIATH CRANE and that the above is a correct report of the result.
B.Tech (Hons).
5.5T lifted upto 5.5 mtr and lowered
Deflection at 5T:10mm at centre spanMovement in Long travel, with 5.5T
load were found satifactory and
stable. No overturning tendencies
were observed.
Below 5T.
-
8/3/2019 EETPL GOLIATH
3/4
PLOT NO: 1205 / A, NAYAPALLI,
BHUBANESWAR - 751012
TEL: 0674 2560284, CELL: 94371 32223
2
1 Name of Occupier of Factory
2 Address of the factory:
3 Distinguishing number or mark, if any,
and description sufficient to identify
the lifting machine, chain, rope or thelifting tackle:
4 Design and construction: Are all the
Parthasarathi Dalai,B. Tech (Hons)COMPETANT PERSON Under Section 2 (ca) of the Factories Act. 1948 RECOGNITION NO: CP (O) NO 55 (G)
No: LTC / PSD / 2010 / EETPL / C.P / TC /
Report of periodic examination of lifting machines, chains,
ropes and lifting tackles
as per FORM 7 - A
[As Prescribed under Rule 55-C , Sub-section (2) of Section 29, Factory Rules, 1950]
01.10.2010
Mr. B. K. Dash
M/s East End Technologies Pvt. Ltd.
Plot No:133-137
IDCO Indl. Estate,
Choudwar, Cuttack.
H.O.T Single Girder Goliath Crane,
Id. No: GOLIATH/CRANE/5T/EETPL-02
Make: EETPL,
Capacity: 5T,
Span: 4mtrs,
Height of Lift: 3mtrs
Mfg Sl. No: Not Available
Location : EETPL FACTORY
PREMISES
Yesparts of hoist or lift of good
mechanical construction, sound material
and adequate strength ( so far as
ascertainable ?
5 Date when the lifting machine, chaain,rope or lifting tackle was first taken
into use in the factory:
6 Date of construction or reconstruction
(if ascertained)
7 Date and number of certificate relating
to any test and examination made under
Rules 55-A and 55-G together with the
name and address of the person who
issued the certificate:
8 Date of each periodical thorough
examination made under Rule 55-F and the
name of examiner:
9 Date of annealing or other heat
treatment of the chain and other lifting
tackle made under Rule 55-E and by whom
it was carried out:
10 Particulars of any defects affecting the
safe working load found at any such
thorough examination or after annealing
and of the steps taken to remedy such
defects:
11 Visual Inspection (for Maintenance):
2009
Year of manufacture: 2009
Not any
Not any
Not any
Nothing observed
Are the following parts of the hoists or lift properly maintained and in good
working order? If not state what defects have been found.
-
8/3/2019 EETPL GOLIATH
4/4
(a) Encloser of Hoistway or Liftway
(b) Landing gates and cage gates(s)
(c) Interlocks and the landing gates and
cage - gate(s)
(d) Other gate fastenings
(e) Cage and platform and fitting, guides
and buffers, interiors of the hoistway
or liftway
(f) Overrunning devices
(g) Suspension ropes or chains and their
attatchments
(h) Safety gear, I.e., arrangement for
preventing fall of platform or cage
brakes
(i) Brakes
(j) Worm or spur gearing
(k) Other electrical equipment
(l) Other parts
12 What parts (if any) were inaccessible
13 Repairs, renwal or alteration (if any)
required and the period within which
they should be executed.
14 Load Testing:
(a) Static tests
Good condition
NA
Good condition
All areas accessible
Not necessary
6.25T held at a height of 0.1mtr
above ground for 10min
NA
NA
NA
Good condition
NA
NA
NA
NA
NA
(b) Dynamic tests
(c) Stability tests
15 Maximum safe working load subject to
repairs, renewals or alterations (if
any) specified in item 5
16 Others
Signature:
Qualification:
Address:
Date:
Plot No: 1205/A, P.O: Nayapalli, Bhubaneswar - 751012.
01.10.2010
I certify that on 01.10.2010, the above HOT GOLIATH CRANE was thoroughly cleaned to the extent
possible and made accessible for through examination and for such tests as were necessary to
ascertain the health of the above HOT GOLIATH CRANE. I have thoroughly examined this HOT
GOLIATH CRANE and that the above is a correct report of the result.
B.Tech (Hons).
Competant Person Regn no: CP(O)NO 55(G)
5.5T lifted upto 5.5 mtr and lowered
Deflection at 5T:10mm at centre spanMovement in Long travel, with 5.5T
load were found satifactory and
stable. No overturning tendencies
were observed.
Below 5T.
-