EDV G Nozzle
-
Upload
paul-boone -
Category
Documents
-
view
104 -
download
3
Transcript of EDV G Nozzle
![Page 1: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/1.jpg)
1
Nicholas ConfuortoBelco Technologies Corporation
Acid Gas Scrubber for Multi-Pollutant Reduction
Emission Control and Measurement Workshop
March 24-25, 2010
![Page 2: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/2.jpg)
2
Founded in 1968, was part of Foster Wheeler until 1989. Now subsidiary of DuPont.
Located in Parsippany, New Jersey
Employing about 65 people
Worldwide Supplier of Technologies for Controls of Particulate, SOX and NOX emissions. Specializing in reduction of Oil Refinery Emissions.
More systems installed and operating than ALL other competitors “COMBINED”
Offering a wide range of solutions to better serve our customers
Certified ISO 9001-2000
Belco Technologies Corporation
![Page 3: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/3.jpg)
3
The The oldold long train Approach To Pollution Controlslong train Approach To Pollution Controls
BoilerESP # 1
ESP # 2
Re-Heat SCR De-
SOxStack
(Particulate)(NOX) (SO2)
FCC
Reducing Particulate, SOx and NOx in a single vessel
(Particulate)(NOX) (SO2)
(No Control of Particulate, SOx or NOx during Boiler Bypass)
![Page 4: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/4.jpg)
4
The The oldold long train Approach To Pollution Controlslong train Approach To Pollution Controls
BoilerESP # 1
ESP # 2
Re-Heat SCR De-
SOxStack
(Particulate)(NOX) (SO2)
FCC
Reducing Particulate, SOx and NOx in a single vessel
(Particulate)(NOX) (SO2)
(No Control of Particulate, SOx or NOx during Boiler Bypass)
THE OLD APPROACH IS:THE OLD APPROACH IS:••COSTLYCOSTLY
••USES TOO MUCH PRECIOUS REFINERY SPACEUSES TOO MUCH PRECIOUS REFINERY SPACE
••IS SUBJECT TO TOO MUCH MAINTENANCE AND POSSIBLE DOWN TIMEIS SUBJECT TO TOO MUCH MAINTENANCE AND POSSIBLE DOWN TIME
••DOES NOT PROVIDE POLLUTION REDUCTION DURING BOILER BYPASSDOES NOT PROVIDE POLLUTION REDUCTION DURING BOILER BYPASS
![Page 5: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/5.jpg)
5
The The oldold long train Approach To Pollution Controlslong train Approach To Pollution Controls
BoilerESP # 1
ESP # 2
Re-Heat SCR De-
SOxStack
(Particulate)(NOX) (SO2)
FCC
Reducing Particulate, SOx and NOx in a single vessel
(Particulate)(NOX) (SO2)
(No Control of Particulate, SOx or NOx during Boiler Bypass)
The Multi-Pollutant Approach To Pollution Controls
Boiler BELCO’sEDV
System
(Pollutants Controlled even during Boiler Bypass)(Pollutants Controlled even during Boiler Bypass)•Less Space Required•Lower Cost•Higher Efficiency•Highest Flexibility•Higher Reliability•Full control even during boiler bypass•Can change with your requirement
FCC
Particulate, Particulate, SOxSOx and NOx combinedand NOx combined
![Page 6: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/6.jpg)
EDV® Wet Scrubbing System Reducing Particulate, SO2, SO3 and NOx in a single vessel
![Page 7: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/7.jpg)
7
No Mist Formation• No Demister• No Mist Fallout
Plot Area• Small• Flexible
Highly ReliableHighly EfficientCan provide Combined Particulate, SO2, NOxand SO3 Control
Non Plugging• Nozzles, Vessel &
Component Design• Handles High Dust
Loads. Even FCCU Upsets
• Highly ReliableModular & Integral
• Single System for all pollutants
• Multi-Staged Collection
EDV®® WetWet ScrubbingScrubbing AdvantagesAdvantages
![Page 8: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/8.jpg)
8
Step 1 – Flue Gas is quenched and saturated in the Quench Section. Initial reduction of particulate, SO2and SO3 is achieved in this step
EDV® Wet Scrubbing Design
![Page 9: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/9.jpg)
9
The EDV® Quench Section
Quench Section
• Designed to fully saturate gas
• Unique design minimizes Wet/Dry interface
• Can be designed to allow the full regenerator temperatures
![Page 10: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/10.jpg)
10
EDV® Wet Scrubbing Design
Step 2 – Reduction of SO2 and Primary Particulate Control is achieved in the Absorber Section
![Page 11: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/11.jpg)
11
The EDV® Absorber Section
Absorber Section
![Page 12: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/12.jpg)
Absorber Spray SectionSO2 & PM Removal
Liquid / Gas ContactStaged Approach
Open Tower DesignSelf CleaningNo Mist FormationLow Pressure Drop
Quench
AbsorberSpray
Section
The EDV® Absorber Spray Section
![Page 13: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/13.jpg)
Cross-Section
The EDV® G® Nozzle
![Page 14: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/14.jpg)
The EDV® G® Nozzle
Cross-Section
![Page 15: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/15.jpg)
15
Plan ViewPlan View Side ViewSide View
![Page 16: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/16.jpg)
16
EDV® Wet Scrubbing Design
Step 3 – Further reduction of fine particulate (PM 2.5 and below) and further reduction of SO2 / and SO3 is achieved in Filtering Modules
![Page 17: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/17.jpg)
17
EDV® Wet Scrubbing System
Filtering Modules (FM’s are applicable only to EDV
5000 and 6000 models)
![Page 18: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/18.jpg)
18
Gas InletGas Inlet
Scrubber ExteriorScrubber Exterior
Internal HopperInternal Hopper
Inte
rnal
Dra
in P
ipe
Inte
rnal
Dra
in P
ipe
Scrubber InteriorScrubber Interior
Multiple Modules in Each ScrubberEfficient and Reliable Fine Particulate Control
![Page 19: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/19.jpg)
19
Condensation & Agglomeration of Fine Particulate & Sulfuric
Acid Mist
Cleaned Gas on to Droplet Separation
Gas Inlet
Cleaned Gas on to Droplet Separation
Liquid to Spray
EDV® 5000 Filtering ModuleEfficient Fine Particulate Control
Fine Particulate
Fine ParticulateEncased in large
water droplet
![Page 20: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/20.jpg)
20
EDV® Wet Scrubbing
Step 4 – Removal of entrained droplets prior to exit through stack
![Page 21: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/21.jpg)
21
EDV® Wet Scrubbing System
Droplet Separators
![Page 22: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/22.jpg)
22
EDV® Wet Scrubbing
Step 5 – Treatment of Scrubber Purge in Purge Treatment Plant (PTU)
![Page 23: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/23.jpg)
23
SCRUBBERPURGE
CLARIFIER
AIR BLOWEROXIDATION TOWERS
EFFLUENT
DISCHARGE
SETTLING BINSSETTLING BINS
Purge Purge TreatmentTreatment Unit Unit EDVEDV®® WetWet ScrubbingScrubbing
Liquid Draining to Liquid Draining to Sump is pumped Sump is pumped back to Clarifierback to Clarifier
Coagulant and/or Flocculent Solution(s)
Caustic Addition for pH controlCaustic Addition for pH controlCaustic Addition for pH control
Concrete Pad with SumpConcrete Pad with Sump
![Page 24: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/24.jpg)
24
SCRUBBERPURGE
CLARIFIER
AIR BLOWEROXIDATION TOWERS
EFFLUENT
DISCHARGE
SETTLING BINSSETTLING BINS
Liquid Draining to Liquid Draining to Sump is pumped Sump is pumped back to Clarifierback to Clarifier
Coagulant and/or Flocculent Solution(s)
Clarifier and settling bin Used For separation of Particulates from purge
Caustic Addition for pH controlCaustic Addition for pH controlCaustic Addition for pH control
Concrete Pad with SumpConcrete Pad with Sump
Purge Purge TreatmentTreatment Unit Unit EDVEDV®® WetWet ScrubbingScrubbing
![Page 25: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/25.jpg)
25
SCRUBBERPURGE
CLARIFIER
AIR BLOWEROXIDATION TOWERS
EFFLUENT
DISCHARGE
SETTLING BINSSETTLING BINS
Liquid Draining to Liquid Draining to Sump is pumped Sump is pumped back to Clarifierback to Clarifier
Coagulant and/or Flocculent Solution(s)
Caustic Addition for pH controlCaustic Addition for pH controlCaustic Addition for pH control
Concrete Pad with SumpConcrete Pad with Sump
Oxidation Needed when scrubbing SO2 to convert Sulfites to Sulfates
Purge Purge TreatmentTreatment Unit Unit EDVEDV®® WetWet ScrubbingScrubbing
![Page 26: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/26.jpg)
Purge Treatment
Unit
EDV® Purge Treatment Unit (PTU)
![Page 27: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/27.jpg)
27
NOx Reduction with EDV® + LoTOxTM
-- Low Temperature Oxidation --
![Page 28: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/28.jpg)
28
EDV Wet Scrubber with LoTOxTM on FCCU
NOxRemoval
SO2 & Particulate Removal PM 2.5 Fine PM 2.5 Fine
Particulate RemovalParticulate Removal
Water Droplet Separation
![Page 29: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/29.jpg)
29
LoTOxTM is sold to refineries worldwide by BELCO® under license from The BOC Group
Patented Process of Injecting Ozone into gas stream to control NOx. Applied following Quench in EDV® Scrubbing System
At Saturation Temperature and with proper mixing and residence time Ozone Reacts with NOX to Form N2O5
Contact with liquid droplets Forms Nitric Acid
Nitric Acid is Stabilized with Caustic to Form Sodium Nitrate
Greater than 90% reduction of NOx is achievedCommercialized in refinery applications. First commercial FCCU application was in May 2006. Many installations since then.Successfully applied to refinery FCCU and many other processesNOT susceptible to plugging, poisoning, masking or deactivation
LoTOxTM NOX Reduction Technology
![Page 30: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/30.jpg)
EDV Wet ScrubbingSpray Tower for LoTOx
TM
Ozone Injection after QuenchConversion to N2O5
Conversion to Nitric AcidConversion to Sodium NitrateMore than 90% NOx reduction is achievedNo problems such as SCR catalyst poisoning, deactivation, sintering and no SO2 to SO3 conversionAble to operate all the time even during boiler bypass
LoTOxLoTOx
InjectionInjection
NO, NONO, NO22 ConversionConversion
to Nto N22OO55
NN22OO55 ConversionConversion
to HNOto HNO33
LoTOxTM is sold to refineries worldwide by BELCO®
under license from The BOC Group
![Page 31: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/31.jpg)
31
Oxygen (O2)
Ozone (O3)ElectricCurrent
Cooling Water
Grounded electrode
GlassDielectric
Cross-Section of Single Ozone Generator Cell
![Page 32: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/32.jpg)
32
LoTOxTM Ozone Generator
![Page 33: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/33.jpg)
33
LoTOxTM data -Medical College of Ohio
Performance of LoTOx System at MCODecember 6, 2001
Outlet NOx Setpoint = 5 PPM Changed to 10 PPM
0
10
20
30
40
50
60
70
80
0:00:0
00:5
2:00
1:44:0
02:3
6:00
3:28:0
04:2
0:00
5:12:0
06:0
4:00
6:56:0
08:4
5:15
9:37:1
510:29
:1511:21
:1512:13
:1513:05
:1513:57
:1514:49
:1515:41
:1516:33
:1517:25
:1518:17
:1519:09
:1520:01
:1520:53
:1521:45
:1522:37
:1523:29
:15
Time
NO
x PP
M
0
5000
10000
15000
20000
25000
30000
35000
40000
Flue
Gas
Flo
w, A
CFM
Flue Gas Temp = 179 - 234 FScrubber Temp = 75 - 100 FInlet SOx = 74 - 178 ppmInlet CO = 150 - 300 ppm
Inlet NOx
Flue Gas Flow
Outlet NOx
![Page 34: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/34.jpg)
34
LoTOxTM data – Refinery FCCU
![Page 35: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/35.jpg)
35
0
10
20
30
40
50
60
70
80
22:55:12 23:02:24 23:09:36 23:16:48 23:24:00 23:31:12 23:38:24
Time
NOx
(ppm
NOx-IN NOx-OUT
Average Reactor Temperature = 153 FSOx in = 211 ppmFlow Rate = 224 scfmAverage NOx Removal = 87%
10 ppm NOx set point
Demonstrated Performance
![Page 36: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/36.jpg)
36
EDV® Wet Scrubbing
Simplified PFD
![Page 37: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/37.jpg)
37
(for EDV(for EDV®® 5000 and 6000 5000 and 6000 models only)models only)
EDV® Caustic System PFD
DIRTY FLUE GAS FROM FCCDIRTY FLUE GAS FROM FCC
CLEAN GAS OUTCLEAN GAS OUT
OVERFLOW DRAINSOVERFLOW DRAINS
EDVEDV®® FILTERING FILTERING MODULESMODULES (for EDV (for EDV
5000, 6000 and 6600 5000, 6000 and 6600 models only)models only)
EDVEDV®® DROPLET DROPLET SEPARATORSSEPARATORS
EDVEDV®®
STACKSTACK
LCLC
FCFCMAKEUP MAKEUP WATERWATER
FCFC
pHCpHC
pHCpHC
CAUSTIC CAUSTIC
FCFC SLIPSTREAM TO
PURGE TREATMENT UNIT
(This loop is for EDV(This loop is for EDV®® 5000, 6000 and 6600 models only)5000, 6000 and 6600 models only)
EDV EDV QUENCHQUENCH
EDV EDV ABSORBERABSORBER
FCFC
EMERGENCY OVERFLOW
Model 1000 Model 5000 Model 6000
![Page 38: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/38.jpg)
38
(for EDV(for EDV®® 5000 and 6000 5000 and 6000 models only)models only)
EDV® Scrubbing System PFD
DIRTY FLUE GAS FROM FCCDIRTY FLUE GAS FROM FCC
EDV EDV ABSORBERABSORBER
CLEAN GAS OUTCLEAN GAS OUT
EDVEDV®® FILTERING FILTERING MODULESMODULES (for EDV (for EDV
5000, 6000 and 6600 5000, 6000 and 6600 models only)models only)
EDVEDV®® DROPLET DROPLET SEPARATORSSEPARATORS
EDVEDV®®
STACKSTACK
LCLC
FCFCMAKEUP MAKEUP WATERWATER
FCFC
FCFC
pHCpHC
pHCpHC
CAUSTIC CAUSTIC
FCFC SLIPSTREAM TO
PURGE TREATMENT UNIT
(This loop is for EDV(This loop is for EDV®® 5000, 6000 and 6600 models only)5000, 6000 and 6600 models only)
EDV EDV QUENCHQUENCH
LoTOxTM
Injection
OZONE GENERATOR
02
03
![Page 39: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/39.jpg)
39
EDV® scrubbing with LoTOxTM ProcessOzone Injection Grid in Quench Section
![Page 40: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/40.jpg)
40
Liquid Discharge elimination using the BELCO LABSORBTM System
![Page 41: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/41.jpg)
41
LABSORBTM
Regenerative SO2 Scrubbing System
ScrubberScrubber
Regeneration Regeneration PlantPlant
![Page 42: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/42.jpg)
42
Sodium Phosphate Solution (“buffer”) used to absorb SO2
Buffer is Regenerated and sent back to the absorber to scrub SO2
Only product from regeneration is a concentrated SO2 stream that is then converted to elemental sulfur or sulfuric acid Reduces load on Waste Water Treatment PlantReduced Reagent Cost (Caustic)Enhanced Recovery (Sulfur)
RegenerativeRegenerative Wet ScrubbingWet ScrubbingLABSORBLABSORBTMTM
![Page 43: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/43.jpg)
Basics - Regeneration SideBuffer Regenerated using Evaporation with low pressure steamSulfates and heat stable salts formed from SO3 and oxidation of SO2 are removed as a solid by a patented processLess than 3% buffer loss
RegenerativeRegenerative Wet ScrubbingWet ScrubbingLABSORBLABSORBTMTM
![Page 44: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/44.jpg)
Installed 9 years ago as SRU tail gas treater at a Refinery in Europe
Operating on a 40,000 bpsd FCCU in Italy since June 2003
Operating on a 60,000 bpsd FCCU in the USA since October 2004
RegenerativeRegenerative Wet ScrubbingWet ScrubbingLABSORBLABSORBTMTM
![Page 45: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/45.jpg)
45
GASGASOUTOUT
LABSORBTM Absorber and Full Pre-scrubber
GAS INGAS INFrom FCCUFrom FCCU
LC
MakeMake--UpUpWaterWater
PrePre--ScrubberScrubberPurge to ClarifierPurge to Clarifier
PREPRE--SCRUBBERSCRUBBER(EDV(EDV®® 6000)6000)
FC
FILTERINGFILTERINGMODULESMODULES
DROPLETDROPLETSEPARATORSSEPARATORS
DROPLETDROPLETSEPARATORSSEPARATORS
111111
222
222
333
333
FCLean BufferLean BufferFrom Regeneration PlantFrom Regeneration Plant
FC Rich Buffer To Rich Buffer To Regeneration PlantRegeneration Plant
LABSORBTM
RegenerationPlant
SOSO22 to Sulfur to Sulfur PlantPlant
PolishingPolishing--ScrubberScrubberBuilt inside stackBuilt inside stack
![Page 46: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/46.jpg)
46
35 PSIG STEAM35 PSIG STEAM
STEAM STEAM CONDENSATECONDENSATE
CondensatCondensate Tank e Tank
Vapor Vapor Liquid Liquid
SeparatorSeparator
EVAPORATOREVAPORATOR
STRIPPERSTRIPPER
CWCWCONDENSERCONDENSER
35 PSIG
MIXINGMIXING
TANKTANK
STRIPPER STRIPPER CONDENSATE TO CONDENSATE TO
SULFATE REMOVALSULFATE REMOVAL
50%NaOH50%NaOH
85% H3PO485% H3PO4
cwcw
BUFFER TO BUFFER TO SULFATE REMOVALSULFATE REMOVAL
COOLERCOOLER
LABSORBTM Regeneration Plant (simplified)“SINGLE EFFECT” EVAPORATION
RICH BUFFER RICH BUFFER FROM FROM
SCRUBBERSCRUBBER
LEAN BUFFER LEAN BUFFER BACK TO BACK TO
SCRUBBERSCRUBBER
Recovered SORecovered SO22 to to SRU or Acid PlantSRU or Acid Plant
![Page 47: EDV G Nozzle](https://reader031.fdocuments.us/reader031/viewer/2022012315/5448a0cdafaf9f49088b4ace/html5/thumbnails/47.jpg)
47
QUESTIONS?