EDS EDS-3G
Transcript of EDS EDS-3G
Most common applications
EDS seriesNew Data Logger with built-in Web Server
Auditing 365 days a year
Measurement and Control
CIRCUTOR, SA - Vial Sant Jordi, s/n 08232 Viladecavalls (Barcelona) Spain Tel. (+34) 93 745 29 00 - Fax: (+34) 93 745 29 14 [email protected]
www.circutor.com
Designed by: communication dept. - CIRCUTOR, SA. Code: C2M633 -01
M61010 EDS - Efficiency Data Server
M61020 EDS - Efficiency Data Server Deluxe (Generic Modbus driver)
M61012 EDS-3G - Efficiency Data Server 3G
M61022 EDS-3G - Efficiency Data Server Deluxe 3G (Generic Modbus driver)
M610A1 Ant. GXS2, 4 GHz 2.14 dbi + 5 m wire
EDS-3G with only GPRS technology, on-demand for large quantities.
Connection with measuring units via Modbus TCP (Modbus via IP on an Ethernet network)
The device can display any calculation or variable of any configured unit.
The Ethernet or 3G network setup can be configured through the device's keyboard (without the need of a computer).
Time synchronisation via NTP servers (network time provider)
8 digital inputs for logic states or counting impulse signals (electric energy meters, water meters, gas meters, etc.). Expandable via auxiliary LM range units.
6 relay outputs controllable via alarm configurations or time controls. Expandable via auxiliary LM range units.
Programming of alarms by any parameter to control the relays of the unit itself or of other auxiliary LM range units.
References
Other features
EDS
EDS-3G
EDS
EDS-3G
Banks
Photovoltaic farms
Communication centres
Centralization of building data
Shopping Centres Industry
Urban settings
Pumping stations
Electric vehicle charging
Livestock operations
Transformer substations
Self & Own consumption systems
Technology for energy efficiency
Ethernet (DSL/ADSL)
CVM MINI
3G
EDS EDMk CVM NRG96 EDS-3G CVM NET CVM NET CVM NET
PowerStudioSCADA
DataBase DataBase
DataBaseServer
V AkWhV A
kWh
8 digital inputs
SQL DataExport OPC-DA ServerAccessories Accessories
8 digital inputs
6 digital outputs activation/deactivation/impulses
6 digital outputs activation/deactivation/impulses
up to 6 units
— Multi connection to EDS or EDS-3G— Individual variable selection— Database migration to SQL— Installation on PCs with Windows®.
— Multi connection to EDS or EDS-3G— Parameters of the units connected to EDS in real time
— IP architecture via tunnelling function with Windows®.
up to 6 units
RS-485
Power meter
Power meter
Energy meter
Power meter
Power meter
Power meter
RS-485
SMS or e-mail Alerts
E-mail Alerts
PowerStudio Embedded platform inside.
WEB Server
System compatible with any XML communication master
Registers of over one year. Up to 4,500 electrical variables, averaged every 15 minutes, maximum and minimum values over the period (Configurable period. Cyclic memory).
RS-485 BUS for connecting up to 6 power analyzers or 12 energy meters.
Internet connection systems that avoid the need for static IPs in the EDS or EDS-3G units. (AMB, DynDNS, CirDNS)
It generates and records its own variables using the data obtained from the units. (EnPi, %, Kg, CO2, Euros, etc.).
Programming to send e-mails to distribution lists with personalized messages, incorporating the information of any variable from the metering units.
Perfect for energy management systemsEDS is a simple, powerful industrial device, able to display, through its built-in Web and XML Server, all the electric variables from power analyzers or other field devices directly related to measuring consumption, electricity, water, gas, etc.
Permanent auditorEDS is the perfect tool for implementing and monitoring ISO 50001 certification systems.