ECPEN14-200_LR_tcm135-316802

172
Solutions OFFICE OFFICE     S     H     O     P COMFORT     A     I     R HEATING     H     E     A     T     I     N     G HEATING HEATING COOLING DESIGN COOLING Commercial TEMPERATURE BANKS BANKS BANKS HOTELS HOTELS HOT WATER HOT WATER RESTAURANTS RESTAURANTS CINEMA     S     C     H     O     O     L     S VENTILATION HUMIDIFICATION EFFICIENCY COMFORT COOLING MIN RUNNING COSTS MAX FLEXIBILITY FAST INSTALLATION PERFECT COMFORT VRV 2014 catalogue

description

VRV

Transcript of ECPEN14-200_LR_tcm135-316802

  • Solutions

    OFFICE

    OFFICESH

    OP

    COMFORT

    AIR HEATING

    HEA

    TIN

    G

    HEATING

    HEATING COOLING

    DESIGN

    COOLINGCommercial TEMPERATURE

    BANKSBANKS

    BANKS

    HOTELS

    HOTELS

    HOT WATER

    HOT WATER

    RESTAURANTS

    RESTAURANTS

    CINEMA

    SCH

    OO

    LS

    VENTILATION

    HUMIDIFICATIONEFFICIENCY

    COMFORT COOLING

    MIN RUNNING COSTSMAX FLEXIBILITY

    FAST INSTALLATIONPERFECT COMFORT

    VRV

    2014catalogue

  • DaikinThe perfect working environment is essential for all businesses. From supermarkets to oces, from public buildings to hotels, from restaurants to shops it is essential that the quality of the air is optimized at all times but no space is used in exactly the same way and that calls for exible, tailored and economic solutions.

    Daikin, Europes leading manufacturer and global N1 in HVAC-R equipment, understands this and our total solution concept is built around customized solutions for individual clients. Whether air conditioning, heating, ventilation, air curtains, hot water, refrigeration or controls, Daikin has the units, the experience and the solution for you.

    Supermarket

    Sport & LeisureStore

    & shopRestaurant

    Hotel

    Oce Technical

    Public building

    http://http://www.daikineurope.com/commercial/

    2

  • VRVEuropean designOver the years, the Daikin VRV systems have been designed with European taste in mind, optimised for the European climate and manufactured in Europe for Europe. As the market leaders, Daikin understands the European market.

    Setting the standard Daikins continuous development of the VRV air conditioning system means it has always been and will always continue as the benchmark standard for European air conditioning systems. The VRV VI is currently setting challenging new standards for seasonal efficiency, optimised climate control and ease of installation.

    A total solutionThe Daikin VRV Total Solution service provides a single point of contact for the design and maintenance of each integrated climate control system. By making a careful choice from our modularised units the right mix of equipment and technology can be selected to ensure the optimal balance of temperature, humidity and air freshness for the perfect comfort zone while delivering maximum energy efficiency, minimum operating costs and reduced CO2 emissions.

    The originalThe VRV air conditioning system is the worlds rst individual air conditioning system with variable refrigerant ow control and was commercialized by Daikin in 1982. VRV is the trademark of Daikin Industries Ltd., which is derived from the technology we call Variable Refrigerant Volume.

    2 3

    VRV

  • 44

    Why choose VRV?Low operating costsOur latest equipment is designed to optimise performance of the total system, automatically, every minute of the day. This includes highly eciency outdoor units, indoor units with intelligent sensors, heat recovery technology, smart energy management controls and much more.

    According to the Franklin + Andrews, one of the worlds leading construction economists, running costs for VRV heat recovery systems compare highly favourably with a 2 or 4 pipe fan coil system. Running costs per m2 Gross Floor Area of a fan coil system can be 40 to 72% higher compared to a VRV heat recovery system.

    A VRV system is more space ecient than a chiller too, because it requires much less plant space. For example, Franklin + Andrews estimates that VRV system could take up 29% less plant space than a chiller system. And in a highly competitive market place, oering the most exible and ecient use of oce space can be a real deal breaker.

    Personal comfort for tenantsWhen viewed from the perspective of the occupants of a building, it is the comfort level provided by the climate control system that is the most important and so the temperature has to be right, there has to be enough fresh air with the correct humidity level and the sound level has to be minimized.

    Our VRV system addresses all of these requirements and provides individual control where possible. Sound levels of our indoor units can be as low as 19 dBA. Futhermore VRV IV continues to provide heating, even when in defrost mode, providing the answer to any perceived disadvatages of using a heat pump for monovalent heating. While in cooling mode it eliminates any cold draught thanks to higher outblow temperatures.

    Meeting tomorrows legislation todayVRV also meets the requirements of the Energyrelated Performance Directive and has been designed for seasonal eciency with future legislative requirements in mind.

    Furthermore the VRV provides greater exibility to meet current and future client requirements, because the system can be designed, built and commissioned zone by zone and tailored to the needs of each building tenant throughout a phased refurbishment programme.

  • 4 5

    VRV

    4

    Precise zone control to suit building occupancyEach oor even each room can be individually controlled to maximise energy eciency and prevent energy waste. This versatility makes VRV ideal for buildings with multiple tenants, which may have vacant areas and variable periods of high and low usage.

    Modular approach gives greater flexibilityVRVs modular approach provides greater exibility to balance heat loads in dierent parts of the building. VRV also oers extended piping lengths so the system can be designed exibly to suit buildings of many dierent sizes and shapes.

    Reliability you can depend onOf course, ensuring lower running costs depends on system reliability and eciency over its entire lifetime. So its reassuring to know that Daikin has an unparalleled reputation for quality, reliability and after sales service.

  • The VRV total solution

    Many buildings today typically operate quite separate systems for heating, cooling, refrigeration and hot water. As a result, a huge amount of energy is wasted. To provide a much more efficient alternative, VRV technology has been developed into a total solution managing up to 50% of a buildings energy consumption giving large potential to cost saving.

    66

    Lighting

    Source: EIA; Commercial buildings Energy consumption survey

    Oce equipment

    Integrate third party equipment

    Space heating

    Space cooling

    Ventilation

    OtherWater heating

    Manage up to 50% of your buildings energy consumption

  • 6 7

    SOLU

    TIO

    NS

    6

    One system, multiple applications

    For hotels, oces, retail, home, ...

    High temperature hydrobox* for ecient hot water production for

    Low temperature hydrobox for highly ecient space heating through

    Showers Sinks Tapwater for cleaning Hot water from 25 to 80C

    Underoor heating Low temperature radiators Heat pump convector Hot water from 25 to 45C

    Ventilation

    Combine VRV indoor units with stylish indoor units in one system.

    New round ow cassette sets the standard for eciency and comfort.

    Mini BMS with integration of Daikin and third party equipment

    Integration with intelligent control solutions with energy management tools to reduce running costs

    A highly ecient solution for doorway climate separation

    Combined fresh air treatment and air conditioning

    Heating & cooling Intelligent control systems22

    Biddle air curtain

    *only for connection to VRV heat recovery

  • Concealed unitEspecially developed for small, well-insulated rooms such as bedrooms

    Centralised control Smart energy management

    Hot waterHeating water with renewable energy

    Intelligent hotel room controller Puts the hotel owner in full control of the energy use

    22

    A hotels reputation depends on how welcome and comfortable guests feel during their stay. Yet at the same time, hotel owners must maintain complete control of their operation costs and energy consumption.

    Hospitality with economy

    88

  • Centralised control Smart energy management

    22

    Eciency in

    Efficient building and facilities management are key to minimising operational costs

    the workplace

    Fully at cassette Design & Genius in one

    Fresh air A healthier oce atmosphere

    Hot waterCutting the cost of hot water

    Centralised control Complete Daikin package for oce building management

    8 9

    SOLU

    TIO

    NS

    8

  • retail costsIn the current commercial environment, retailers are under pressure to reduce both store development and running costs. Legislation adds further nancial pressure with dierent energy ecient schemes. Therefore aordable, energy ecient solutions are vital to minimise lifetime costs, while ensuring compliance with the latest regulations.

    Reducing

    Round ow cassette with auto cleaning panel50% energy saving compared to standard cassettes

    Biddle air curtain Highly ecient solutions to combat the issue of climate separation across your doorway

    User-friendly control Create a comfortable environment for customers

    22

    1010

  • Residential solutionsThere is no place like home.

    22 Daikin EmuraRemarkable blend of iconic design and functionality

    22 NexuraCombines the feel of a radiator with the comfort and eciency of a heat pump

    Did you know that when you opt for a Daikin air conditioner, you are also thinking of the environment?When we produce your air conditioner, we do our utmost to recycle, reduce waste and use renewable energy.

    10 11

    SOLU

    TIO

    NS

    10

  • What is new?

    Replacement VRV IV heat recovery - RXYQQ-T VRV IV standards: Variable Refrigerant Temperature, Continuous heating,

    VRV configurator & 7 segment display VRV IV technologies Covers all thermal needs of a building: hot water (LT & HT hydrobox),

    ventilation, air handling unit and Biddle air curtains Free heating and hot water by recovering heat from areas requiring cooling The perfect personal comfort for guests/tenants via simultaneous cooling

    and heating Unique range of single and multi BS boxes

    Water cooled VRV IV - RWEYQ-T VRV IV standards: Variable Refrigerant Temperature, VRV configurator

    & 7 segment display Covers all thermal needs of a building: hot water (LT hydrobox), ventilation,

    air handling unit and Biddle air curtains Unified range for standard and geothermal series simplifies stock Variable Water Flow control of water pump increases flexibility

    and control

    Integrating VRV IV technologies on the full outdoor unit range p66 / p72

    VRV IV heat recovery REYQ-T p44360 efficiency

    1212

    Improved operational efficiency: Improved efficiency during heat recovery mode with 15% Free heating or hot water by recovering heat from areas requiring cooling Optimal comfort for everybody by simultaneous

    cooling spaces while heating others

    Improved design efficiency: Integrated climate control covering all thermal loads in the building Free combination of outdoor units, single and multi BS boxes

    Unique range of single and multi BS boxes

    Improved installation efficiency: Fully redesigned multi BS boxes, smaller and up to 70% lighter No limit on number of unused ports Connect indoor units up to 28kW to a single and multi BS box

  • Daikin Emura - FTXG-LW/S p100 Unique design. Designed in Europe for Europe. Improved comfort thanks to 2-area intelligent eye, 3D air flow, sound levels down to 19dBA Connectable to VRV IV and VRVIII-S heat pump

    Plug & play connection to Daikin Air Handling Units p124 Complete plug & play solution including AHU, ERQ or VRV condensing unit

    and all unit control (EKEQ, EKEX, DDC controller), factory mounted and configured

    Used when the commercial ventilation range cannot satisfy the ventilation requirement (up to 140,000 m3/h)

    High efficiency High comfort levels thanks to rapid response of ERQ and VRV to

    temperature fluctuations

    Heat reclaim ventilation - VAM and VKM p118 High energy efficiency with DC fan motors Optional CO2 sensor saves energy while improving indoor air quality Optional medium (M6) and fine (F7, F8) dust filters for VAM-FB Shorter installation time thanks to easy adjustment of nominal air flow rate Total fresh air solution with optional supply of electrical heater

    (VAM-FA/FB)

    Simplified wired remote control for hotel applications p135 Symbol driven interface for intuitive control Contemporary design Change set point automatically when guests leaves the room or opens the

    window, saving energy Meets all the guests needs because every room is individually controlled

    - DCM601A51 p138 Cost competitive mini BMS Cross-pillar integration of Daikin products (VRV hydroboxes,

    air curtains, AHU, refrigeration indoors, Chillers, ) Integration third party equipement via WAGO and BACnet

    12 13

    WAT

    HS

    NEW

    12

  • Super store

    Hotel santos porta raPorta ra

    This project reinforces Daikin's position as a leader in the air conditioning of large-scale structures, able to provide solutions that stand out not only for their accuracy and reliability, but also for their energy eciency.

    74 outdoor units (60 x VRV heat recovery outdoor units) controlled via Intelligent manager, 664 indoor units, 2 x air cooled chillers (EWAD 600 BJYNN/Q)

    The Range, UK7 x VRV IV heat pump with continuous heating,

    71 round ow cassettes, RTD control,

    Intelligent Touch Manager

    The RangeWe were very happy to work with Daikin UK to incorporate one of the latest fully integrated renewable systems that would provide heating, hot water, and air conditioning, allowing The Range at Warrington to have a fully controllable system with operation exibility according to requirements. Brad Hurter, CDS Group

    Our references

    1414

  • Which VRV outdoor system

    Heat Pump VRV IV heat pump Covers all thermal needs of a building: hot water (LT hydrobox), ventilation, air handling unit

    and Biddle air curtains Connectable to stylish indoor units (Daikin Emura, Nexura)

    VRV IV standards: Variable Refrigerant Temperature, Continuous heating, VRV configurator & 7 segment display

    VRV IV technologies

    VRVIII-S Especially designed

    for small capacities

    Space saving design Either connect VRV or

    stylish indoor units: Daikin Emura, Nexura

    VRV Classic For smaller projects

    with standard cooling & heating requirements

    Connectable to all VRV indoor units, controls and ventilation

    VRVIII-Coptimised for heating Developed for heating

    operation at low ambient conditions.

    Extended operation range for heating down to -25C

    Stable heating capacity and high efficiencies at low ambient temperatures

    Other VRV heat pumps

    Cost-effective upgrade for R-22 systems, which cannot be serviced and maintained anymore after 01/01/2015

    Fast replacement Up to 81% more efficient than an R-22 system VRV IV standards: Variable Refrigerant Temperature,

    VRV configurator & 7 segment display VRV IV technologies Connectable to ventilation, air handling units and Biddle air curtains Available in heat recovery and heat pump

    REPLACEMENT

    Heat Recovery Covers all thermal needs of a building: hot water (LT & HT hydrobox), ventilation, air handling unit and Biddle air curtains

    Free heating and hot water by recovering heat from areas requiring cooling The perfect personal comfort for guests/tenants via simultaneous cooling and heating

    Unique range of single and multi BS boxes VRV IV standards: Variable Refrigerant Temperature,

    Continuous heating, VRV configurator & 7 segment display VRV IV technologies

    Unified range for standard and geothermal series simplifies stock Variable Water Flow control of water pump increases flexibility and control VRV IV standards: Variable Refrigerant Temperature,

    VRV configurator & 7 segment display Covers all thermal needs of a building: hot water

    (LT hydrobox), ventilation, air handling unit and Biddle air curtains

    Allows heat recovery within the total building, thanks to the storage of energy in the water circuit. Compact design and stacked configuration possible. Suitable for multi-storey and large buildings because of the hardly unlimited possibilities of water piping.

    the best solution?offers me

    14 15

    PORT

    FOLI

    O

    14

  • new

    1 Not a standard combination (free combination)

    AIR

    CO

    OLE

    D

    HEA

    T PU

    MP

    RYYQ-T Heat pump with

    continuous heating

    RXYQ-T Heat pump without continuous heating

    RXYSQ-P8V1 (Single phase)RXYSQ-P8Y1 (Three phase)

    RTSYQ-PA Heat pump

    optimised for heating

    RXYCQ-A

    HEA

    T R

    ECO

    VER

    Y

    REYQ-T

    REYQ-P8/P9 Small footprint combination

    REYHQ-P High COP combination

    REYAQ-P

    for connection with heating only hydrobox

    WAT

    ER

    COO

    LED

    HEA

    T R

    ECO

    VER

    Y

    HEA

    T PU

    MP

    RWEYQ-T

    System Type Product name 4 5 8 10 12 13 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54

    Capacity class 140 280 360 460 500 540 636 712 744 816 848

    Single unit

    Multi combination

    *1 *1 *1

    *1 *1 *1

    *1 *1 *1

    System Type Product name 4 5 6 8 10 12 13 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54

    *1 *1 *1 *1 *1

    AIR

    CO

    OLE

    D

    REP

    LAC

    EMEN

    T V

    RV

    HEA

    T R

    ECO

    VER

    Y -

    HEA

    T PU

    MP

    RXYQQ-T

    VRVIV-Q - H/P

    RQCEQ-P

    VRVIII-Q - H/R

    new

    new

    Outdoor unit rangePortfolio

    1616

  • : component is connectablex : component is not connectableNot all components are connectable at the same time to one outdoor unit. Refer to the engineering databook for more information.

    AIR

    CO

    OLE

    D

    HEA

    T PU

    MP

    RYYQ-T Heat pump with

    continuous heating

    RXYQ-T Heat pump without continuous heating

    RXYSQ-P8V1 (Single phase)RXYSQ-P8Y1 (Three phase)

    RTSYQ-PA Heat pump

    optimised for heating

    RXYCQ-A

    HEA

    T R

    ECO

    VER

    Y

    REYQ-T

    REYQ-P8/P9 Small footprint combination

    REYHQ-P High COP combination

    REYAQ-P

    for connection with heating only hydrobox

    WAT

    ER

    COO

    LED

    HEA

    T R

    ECO

    VER

    Y

    HEA

    T PU

    MP

    RWEYQ-T

    System Type Product name 4 5 8 10 12 13 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54

    Capacity class 140 280 360 460 500 540 636 712 744 816 848

    Control systems

    Hydrobox connection

    x

    x

    x

    x

    x

    x

    x

    x

    x

    x

    x

    x

    x

    x

    x

    x

    x

    x

    Air curtain

    x

    Ventilation

    x

    x

    Indoor units

    x

    x

    x

    x

    x

    x

    x

    x

    x

    Capacity (HP)

    Capacity (HP)

    *1 *1 *1

    *1 *1 *1

    *1 *1 *1

    System Type Product name 4 5 6 8 10 12 13 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54

    Netw

    ork s

    olut

    ions

    (suc

    h as

    DCS

    6*/D

    AM/D

    MS)

    Cent

    ralis

    ed co

    ntro

    l (suc

    h as

    DCS

    3*/D

    ST)

    Indi

    vidua

    l con

    trol (s

    uch

    as B

    RC)

    High

    tem

    pera

    ture

    hyd

    robo

    x for

    VRV

    Low

    tem

    pera

    ture

    hyd

    robo

    x for

    VRV

    Bidd

    le Ai

    r cur

    tain

    for V

    RV (C

    YV)

    AHU

    conn

    ectio

    n kit

    (suc

    h as

    EKEX

    V)

    Fres

    h air

    indo

    or u

    nits

    (such

    as FX

    MQ-

    MF)

    Heat

    Rec

    laim

    vent

    ilatio

    n (su

    ch as

    VAM

    )

    Resid

    entia

    l typ

    e ind

    oor u

    nits

    (such

    as D

    aikin

    Emur

    a)

    VRV

    type

    indo

    or u

    nits

    (such

    as FX

    SQ)

    AIR

    CO

    OLE

    D

    REP

    LAC

    EMEN

    T V

    RV

    HEA

    T R

    ECO

    VER

    Y -

    HEA

    T PU

    MP

    RXYQQ-T

    VRVIV-Q - H/P

    RQCEQ-P

    VRVIII-Q - H/R

    22

    16 17

    PORT

    FOLI

    O

    16

  • Type Model Product name 15 20 25 32 40 50 63 71 80 100 125 140 200 250

    CEIL

    ING

    MO

    UN

    TED

    CA

    SSET

    TE

    Round ow cassetteautocleaning function3

    Presence & oor sensor3FXFQ-A

    Fully at cassettePresence & oor sensor3 FXZQ-A

    2-way blow ceiling mounted cassette

    FXCQ-A

    Ceiling mounted corner cassette

    FXKQ-MA

    CON

    CEA

    LED

    CEI

    LIN

    G

    Small concealed ceiling unit FXDQ-M9

    Slim concealed ceiling unit FXDQ-A

    Concealed ceiling unit

    with inverter driven fanFXSQ-P

    Concealed ceiling unit with inverter driven fan

    FXMQ-P7

    Large concealed ceiling unit

    FXMQ-MA4

    WAL

    L M

    OUN

    TED

    Wall mounted unit FXAQ-P

    CEIL

    ING

    SU

    SPEN

    DED Ceiling suspended unit FXHQ-A

    4-way blow ceiling suspended unit

    FXUQ-A

    FLO

    OR

    STA

    ND

    ING

    Floor standing unit FXLQ-P

    Concealed oor standing unit

    FXNQ-P

    1 Nominal cooling capacities are based on: indoor temperature: 27CDB, 19CWB, outdoor temperature: 35CDB, equivalent refrigerant piping: 5m, level difference: 0m. 2 Nominal heating capacities are based on: indoor temperature: 20CDB, outdoor temperature: 7CDB, 6CWB, equivalent refrigerant piping: 5m, level difference: 0m 3 Optional4 Not connectable to VRV III-S

    Capacity

    Cooling capacity (kW)1 1.7 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 11.2 14.0 16.0 22.4 28.0

    Heating capacity (kW)2 1.9 2.5 3.2 4.0 5.0 6.3 8.0 9.0 10.0 12.5 16.0 18.0 25.0 31.5

    With 20 different indoor unit types and a range of 14 different capacities available, VRV indoor units fit rooms of any size or shape, tailored to the needs of the building owner.

    Indoor unit range

    1818

  • CapacityConnectable outdoor unit

    Type Model Product name 15 20 25 35 42 50 60 71RYYQ-TRXYQ-T

    RXYSQ-P8V1RXYSQ-P8Y1

    CEIL

    ING

    MO

    UN

    TED

    C

    ASS

    ETTE

    Round ow cassette(incl. autocleaning function1)

    FCQG-F Fully at cassette FFQ-C

    CON

    CEA

    LED

    CEI

    LIN

    G Small concealed ceiling unit FDBQ-B Slim concealed ceiling unit FDXS-F(9)

    Concealed ceiling unit with inverter driven fan FBQ-C8

    WA

    LL M

    OU

    NTE

    D

    Daikin Emura

    Wall mounted unitFTXG-LW/

    LS Wall mounted unit

    CTXS-K FTXS-K

    Wall mounted unit FTXS-G

    CEILI

    NG

    SUSP

    ENDE

    D

    Ceiling suspended unit FHQ-C

    FLO

    OR

    STA

    ND

    ING

    Nexura oor standing unit FVXG-K Floor standing unit FVXS-F

    Flexi type unit FLXS-B(9)

    new

    1 Decoration panel BYCQ140CG + BRC1E51A needed

    18 19

    PORT

    FOLI

    O

    18

  • Ventilation range

    Air ow rate (m3/h)

    Type nameComponents

    of indoor air quality 0 200 400 600 800 1,000 1,500 2,000 4,000 6,000 8,000 124,000

    HEAT RECLAIM

    VENTILATION

    VAM-FA/FB Ventila tion

    Heat recovery

    VKM-GB Ventila tion Heat recovery Air processing

    VKM-GBM Ventila tion Heat recovery Air processing Humidification

    OUTDOOR AIR PROCESSING

    UNIT 1FXMQ-MF

    Ventila tion Air processing

    AIR HANDLING UNITS

    DX total fresh air package

    Ventila tion Heat recovery Air processing Humidification Filtration

    1 Not connectable to VRVIII-S (RXYSQ-PAV, RXYSQ-PAY)2 Air flow rate is a calculated indication only, based on the following values: heating capacity EKEXV-kit * 200m3/h3 Daikin AHU connected to Daikin chiller solution

    Ventilation: provision of fresh air

    Humidification: optimise the balance between indoor and outdoor humidity

    Heat recovery: recovers heat and moisture from the outgoing air to maximise comfort & efficiency

    Air processing: heats or cools incoming fresh air maximising comfort and minimizing the load on the air conditioning installation

    Filtration: Removes dust, pollution and odours from the air

    (3)

    2020

  • Network solutions

    Layo

    ut sc

    reen

    Touc

    h sc

    reen

    Min

    i BM

    S fo

    r hea

    ting,

    air

    cond

    ition

    ing

    ap

    plie

    d sy

    stem

    s & re

    frige

    ratio

    n un

    its

    3rd

    part

    y eq

    uipm

    ent i

    nteg

    ratio

    n

    Basic

    con

    trol

    func

    tions

    :on/

    o, t

    emp,

    sett

    ing,

    ai

    r ow

    sttin

    gs

    Refri

    gera

    nt c

    onta

    inm

    ent c

    heck

    Tem

    pera

    ture

    lim

    itatio

    n

    Setb

    ack

    Auto

    mat

    ic c

    hang

    eove

    r

    Wee

    kly

    sche

    dule

    & sp

    ecia

    l day

    pat

    tern

    Tim

    er e

    xten

    sion

    Forc

    ed o

    Basic

    con

    trol

    func

    tions

    : ON

    /OFF

    stat

    us, o

    pera

    tion

    mod

    e, se

    t poi

    nt te

    mp.

    Filte

    r sta

    tus

    Mal

    func

    tion

    code

    Hist

    ory

    (ope

    ratio

    n, m

    alfu

    nctio

    n)

    Visu

    alisa

    tion

    PPD

    Web

    acc

    ess &

    con

    trol

    HTT

    P op

    tion

    Inte

    rlock

    Pre-

    cool

    /hea

    t

    Slid

    ing

    tem

    pera

    ture

    Free

    coo

    ling

    ACN

    SS co

    nnec

    tion

    Air C

    ondi

    tionn

    ing

    Net

    wor

    k Se

    rvic

    e Sy

    stem

    Max

    imum

    indo

    or u

    nit g

    roup

    s

    ITC 64

    ITM (3) (3) + + + + Std + 2560

    DMS-IF 1 64

    BACNET 2 4x64

    Screen Integration Control Monitoring Options Other

    Biddle air curtain range

    Hydrobox range

    1 Gateway for Lonworks networks 2 Gateway for BACnet networks 3 BACnet and WAGO

    2.3m2.15m 2.0m

    3.0m2.75m

    2.5m2.5m 2.4m 2.3m

    Installation conditionFavourableex: covered shopping mall or revolving door entrance

    Normalex: little direct wind, no opposite open doors, building with ground floor only

    Unfavourableex: location at a corner or square, multiple floors and / or open stairwell

    S M L S M L M L

    4

    3

    2

    1

    Door height (m)

    S

    Type Product Name

    BIDDLE AIR CURTAIN FREE HANGING CYV S/M/L-DK-F

    BIDDLE AIR CURTAIN CASSETTE CYV S/M/L-DK-C

    BIDDLE AIR CURTAIN RECESSED CYV S/M/L-DK-R

    Type Product name Leaving water temperature range 80 125

    LOW TEMPERATURE HYDROBOX HXY-A 5C - 45C

    HIGH TEMPERATURE HYDROBOX HXHD-A 25C - 80C

    Capacity

    20 21

    PORT

    FOLI

    O

    20

  • Medical laboratory

    Oce and residential project

    Labo LADRTotal building approach using waste heat for oces and allowing individual control

    4 x VRV heat recovery outdoor units (1 x REYQ42P8; 1 x REYQ44P8 1 x REYQ46P8; 1 x REYQ48P8)2 x Sky Air outdoor units (RZQ200C)4 x Sky Air indoor units (FHQ100B)Ventilation via air handling unitsControl via Intelligent Touch Controller

    VRV: 8 x VRV III heat recovery outdoor units (8 x REMHQ12P8) 151 x VRV III heat pump outdoor units (57 x RXYQ18P9; 1 x RXYQ8P9; 1 x RXYQ10P9; 5 x RXYQ12P9; 2 x RXYQ16P9; 21 x RXYSQ4P8Y1; 2 x RXYSQ5P8Y1; 2 x RXYSQ6P8Y1)653 x VRV indoor units

    Ventilation: 10 x ERQ250AW1; 154 x VAM500FA; 90 x VAM250FA; 42 x VAM800FA; 12 x VAM600FA

    Sky Tower The high quality of presales service provided by the Daikin sales team, the proposed solution with proven reliability from past references and extensive research to oer the best solution convinced the customer.

    Our references

    2222

  • Advanced software tools for system design assistance, enabling you to select & sell the product that ts your customer needs

    Sales supporting apps Daikin E-data app contains an overview of all Daikin Europe N.V. products that are available in your country, in your own language. You can easily browse the products to nd the engineering data you need.

    Tools

    For a complete line-up of tools & downloads, visit:

    Selection software Xpress

    Xpress is a exible design software to optimise equipment selection in cost and it enables you to make a high ecient building design.

    VRV Pro

    VRV pro is a true VRV design tool. The program enables VRV air conditioning systems to be engineered in a precise and economical way, taking into account the complex piping rules. Moreover, it ensures optimum operating cycles and maximum energy eciency. In this way, it gives the designer the possibility to make accurate selections and get competitive quotations for each project.

    Seasonal Solutions Simulator With this software tool you can simulate the seasonal eciency, the annual power consumption and CO2 emission for a given climate, load prole (cooling, heating, heat recovery, covalent, bivalent) and (combination of ) system(s). With its intuitive and graphical appealing interface, a simulation can be made in a matter of minutes. The solution basket system enables you to compare the results of several system congurations.

    http://extranet.daikineurope.com/en/software/default.jsp

    or contact your local representative

    22 23

    PORT

    FOLI

    O

    22

  • VRV IV =3 revolutionary standards

    2424

    Variable refrigerant temperature

    Continuous comfort during defrost

    VRV congurator

    + VRV IV technologies

    + Integrated climate control

  • 1. Variable refrigerant temperature

    Customize your VRV for best seasonal eciency & comfort.Thanks to its revolutionary varialble refrigerant temperatue technology, VRV IV continuously adjusts the refrigerant temperature to the actual temperature and capacity needed, thus providing optimal seasonal eciency at all times.

    Improved seasonal efficiency with 28% Weather dependent Customer comfort is assured with automatic adjustement of refrigerant temperature leading

    to higher outblow temperatures (avoiding cold draft)

    Automatic mode (Default setting on VRV IV)

    The perfect balance : Top eciency throughout most of the year. Quick reaction speed on the hottest days

    Quick reaction to peak load, to maintain set point

    Basic mode (current VRF standard)

    Year round top eciency

    High sensible mode

    Top eciency

    Quick reaction speed

    Top eciency

    Quick reaction speed

    Top eciency

    Quick reaction speed

    Different modes: The system can be easily customised via preset modes. With the modes you choose to optimise the system towards your required balance between comfort and efficiency

    Automatic mode (Default setting on VRV IV) Basic mode (current VRF standard)High sensible modeLoad

    Refrigerant volume (VRV) Refrigerant volume (VRV) Refrigerant volume (VRV)

    Refrigerant temperature (VRT)Refrigerant temperature (VRT)

    Refrigerant temperature (VRT)

    LoadLoad

    Eciency EciencyEciency

    Effect of preset modes on efficiency and reaction speed:

    Unique VRT automatic mode leads to 28% increase in seasonal efficiency In automatic mode the system will go for maximum eciency throughout most of the year and for quick reaction speed on the hottest days, ensuring comfort at all times while still resulting in an increased seasonal eciency up to 28%.

    The perfect balance : Maximum eciency throughout most of the year. Quick reaction speed on the hottest days

    Automatic mode (Default setting on VRV IV)

    Top eciency

    Quick reaction speed

    24 25

    VRV I

    V

    TECH

    NOLO

    GIES

    24

  • Heat pumps are known for their high energy efficiency in heating, but they accumulate ice during heating operation and this must be melted periodically using a defrost function that reverses the refrigeration cycle. This causes a temporary temperature drop and reduced comfort levels inside the building.

    Defrosting can take over 10 minutes (depending on the size of the system) and occurs most frequently between -7 and +7C when there is most humidity in the air, which freezes to the coil, and this has a significant impact on the perceived indoor comfort levels.

    The VRV IV has changed the heating pardigm by providing heat even during defrost operation thus eliminating the temperature drop inside and providing comfort at all times.

    VRV IV

    VRF benchmark

    Room temperature

    TimeT

    new

    2. Continuous heating during defrost

    A unique heat-accumulating element, based upon phase change materials, provides the energy to defrost the outdoor unit. The energy needed for defrosting is stored in the element during normal heating operation.

    How does it work?Heat accumulating element

    Alternate defrost

    The outdoor unit coil is defrosted

    with the energy stored in the heat accumulating element

    while indoors a comfortable temperature is maintained.

    VRV IV continues to provide heating even when in defrost mode, providing an answer to any perceived disadvantages of specifying a heat pump for monovalent heating.

    Indoor comfort not affected either via the unique heat accumulating element or alternate defrost The best alternative to traditional heating systems

    the outdoor unit coil is defrosted

    one at the time

    so indoors a comfortable temperature is maintained

    On all our multi model combinations only 1 outdoor coil is defrosted at a time, ensuring continuous comfort during the whole process.

    2626

  • 3. VRV congurator software

    Simplified commissioning The VRV configurator is an advanced software solution that allows for easy system configuration and commissioning:

    less time is required on the roof conguring the outdoor unit multiple systems at dierent sites can be managed in exactly the same way, thus oering simplied commissioning forkey accounts initial settings on the outdoor unit can be easily retrieved.

    Simplied commissioning

    Retrieve initial system settings

    User friendly interface instead of

    push buttons

    Simplified servicing Outdoor unit display for quick on-site settings and easy read out of errors together with the indication of service parameters for checking basic functions.

    easy-to-read error report clear menu indicating quick and easy on-site settings indication of basic service parameters to quickly check

    basic functions: high pressure, low pressure, frequency ans operation time history of compressors, temperature of discharge/suction pipe. 3 digit 7-segment display

    Software for simplied commissioning, conguration and customisation

    Graphical interface Manage systems over multiple sites in exactly the same way Retrieve initial settings

    26 27

    VRV I

    V

    TECH

    NOLO

    GIES

    26

  • 12

    3

    4

    1 Newly developed compressor Full inverter Enabling Variable Refrigerant Temperature and low start-up currents Stepless capacity controlReluctance brushless DC motor increased efficiency compared to AC motors by simultaneous using normal and

    reluctance torque Powerful neodymium magnets efficiently generate high torque High pressure oil reduces thrust lossesHigh efficinency J-type 6-pole motor 50% stronger magnetic force & higher rotation efficiencyNewly developed compressor material Compression volume is increased with 50% thanks to a new high strenght material casted

    in a semi molted state (thixocasting process)

    2 4-side heat exchanger Up to 50% more heat exchange surface (up to 235m2) leading to 30% better efficiency

    new

    new

    VRV IV technologies

    new compressor

    material

    6 pole motor

    DC motor

    2828

  • new

    4 DC Fan Motor Outer rotor DC motor for higher efficiency Bigger diameter of the rotor results in greater force for the same magnetic field Better control resulting in more fan steps to match the actual capacity

    DC Fan MotorThe use of a DC fan motor offers substantial improvements in operating efficiency compared to conventional AC motors, especially during low speed rotation.

    5 E-Pass Heat Exchanger Optimization of the path layout of the heat exchanger prevents heat transferring from the overheated gas section towards the sub cooled liquid section - a more efficient use of the heat exchanger.

    Sine Wave DC InverterOptimizing the sine wave curve, results in smoother motor rotation and improved motor efficiency.

    3 Gas cooled PCB Reliable cooling as it is not influenced by ambient air temperature Smaller switchbox for smoother air flow through the heat exchanger

    DC motor efficiency(comparison with a conventional AC motor)

    Motor speed (rpm)

    200 300 400 500 600 700 800 900 1000

    100

    80

    60

    40

    20

    0Ef

    ficie

    ncy

    (%)

    AC motor

    IN 85C

    27C

    60C

    55C

    27C

    27C

    OUT 45

    OUT 45

    e-Pass heat exchanger

    43C

    IN 85C

    27C

    55C

    50C

    27C

    27C

    OUT 45

    OUT 45

    Standard heat exchanger

    55C

    6 I-Demand Function The newly introduced current sensor minimizes the difference between the actual power consumption and the predefined power consumption.

    Pow

    er

    cons

    umpt

    ion

    (KVV

    )

    8:00 12:00 16:00 20:00

    Time

    FF

    Conventional motor with inner rotor

    Daikin outer rotor

    rotor rotor

    28 29

    VRV I

    V

    TECH

    NOLO

    GIES

    28

  • OFFOFF

    ON

    ON

    ON

    Benefits for building ownersDrastically reducing your running costsA long lasting investment

    Precise zone control VRV systems have low running costs because it permits each zone to be controlled individually. That is, only those rooms that require air conditioning will be heated or cooled, while the system can be shut down completely in rooms where no air conditioning is required.

    Smart energy management Smart energy management tools reduce running costs by preventing energy wastage. Using the schedule function and monitoring tools you can easily detect origins of energy waste and track consumption to ensure it is according to plan. Our intelligent tools maximize efficiency at all times.

    Indication of where energy saving is possible

    All inverter compressors All inverter control compressors allow to control the refrigerant volume almost stepless. In this way the capacity perfectly matches the different loads in every room avoiding unnecessary energy use.

    Additionally all inverter compressors also allow precise refrigerant temperature control, automatically adapting your VRV to your building and climate requirements, reducing runnig costs with 28%.

    ALL

    3030

  • Intelligent indoor units The round flow cassette, Daikins technology flagship indoor unit, shows that intelligent indoor units lead to great savings in runnings and pays itself back in no time!

    30 31

    BEN

    EFIT

    S

    30

    Auto-cleaning panelThe auto-cleaning filter automatically cleans itself once a day preventing the filter gets dirty, leading up to 50% savings. Dust can be simply removed from the unit with a vaccuum cleaner.

    50% lower energy consumption

    09.00

    Inside temp. (CDB)

    26

    24

    22

    20

    Presence sensor saves up to 27%

    Cooling set point : 22 CDB

    Energy saved

    no presence detected for 15mins

    May

    JuneJu

    ly

    Augu

    st

    Sept

    embe

    r

    Octo

    ber

    Nove

    mbe

    r

    Dece

    mbe

    r

    Janu

    ary

    Febr

    uary

    March Ju

    lyAp

    ril

    Test of auto cleaning panel versus normal panel

    Energy consumption (kWh)

    (Test site, Wolverhampton, UK)

    9000800070006000500040003000200010000 Standard round flow cassette

    with regular servicing

    Auto cleaning cassette

    09.30

    10.00

    10.30

    11.00

    11.30

    12.00

    12.30

    13.00

    13.30

    14.00

    14.30

    15.00

    15.30

    16.00

    16.30

    17.00

    Nobody in the room

    Presence sensorThe presence sensor adjusts the set point or switches off the unit if no persons are in the room, preventing up to 27% of unnecessary energy use. At the same time it can detect people and direct the airflow away from them for added comfort.

  • Heat exchanger

    An anti-corrosion heat exchanger cutaway view

    Aluminium

    Hydrophilic film

    Corrosion-resistantAcrylic resin

    Anti Corosion Treatment Special anti corrosion treatment of the heat exchanger provides 5 to 6 times greater resistance against acid rain and salt corrosion. The provision of rust proof steel sheet on the underside of the unit gives additional protection.

    Performed tests:VDA Wechseltest Contents of 1 cycle (7 days): 24 hours salt spray test SS DIN 50021 96 hours humidity cycle test KFW

    DIN 50017 48 hours room temperature & room

    humidity testing period: 5 cycles

    Kesternich test (SO2) contents of 1 cycle (48 hours)

    according to DIN50018 (0.21) testing period : 40 cycles

    8

    6

    4

    2

    01 2 3 4 5

    Cycle

    Cycle

    Degree of corrosion

    Degree of corrosion

    DAIKIN P.E.

    Bare aluminium

    7

    1

    3

    5

    109876543210 1 2 3 4 5 6 10 20 30 40 50 60 70

    Duty Cycling extends operation life The cyclical start-up sequence of multiple outdoor units systems equalises compressor duty and extends operating life.

    Sequential Start Up to 3 outdoor units can be connected to 1 power supply and can be turned on sequentially. This allows the number of breakers and their capacities to remain small and simplifies wiring (for models of 10HP or less).

    Up to 6 times greater resistance against corrosion

    Only one power supply3232

  • Both from a technical and eciency point of view, we could oer the best solution, but, most important, the complex solution was made look easy for the customer as he only had one point of contact for both the HVAC systems and controls. A service only Daikin could oer.

    R & D building

    15 x VRV IV heat pump with continuous heating outdoor units (RYYQ-T (254hp)

    123 x VRV indoor units (54 x FXSQ-P; 28 x FXHQ-MA 25 x FXZQ-A; 8 x FXAQ-P; 8 x FXLQ-P)

    ventilation: 5 x ERQ-A; 5 x EKEQFCB+EV control: via Intelligent Touch Manager

    Edicio contenedor de institutos

    administration building and storage

    Kaee Partner

    7 x VRV heat pump outdoor units: (2 x RXYQ12P9; 2 x RXYQ14P9; 1 x RXYQ16P9; 1 x RXYQ22P; 1 x RXYQ8P9); 3 x ERQ250AW1;

    114 x VRV indoor units: (2 x FXSQ20P; 13 x FXSQ40P; 5 x FXZQ15M9; 21 x FXZQ20M9; 26 x FXZQ25M9; 4 x FXZQ32M9; 9 x FXZQ40M9; 4 x FXZQ50M9)

    Kaffee Partner chose Daikin VRV for its efficiency, low investment and small footprint.

    Our references

    32 33

    BEN

    EFIT

    S

    32

  • Benefits forend users

    Smart Control Brings Comfort Stable room temperatureAn electronic expansion valve, using PID (Proportional Integral Differencial) control, continuously adjusts the refrigerant volume in respond to load variations of the indoor units. The VRV system thus maintains comfortable room temperatures at a virtually constant level, without the temperature variations typical of conventional ON/OFF control systems.

    No more cold draughtAutomatic or manual adjustment of refrigerant temperature leads to higher outblow temperatures which avoid the cold draught coming from the indoor unit.

    VRV SERIES (DAIKIN indoor unit (PID controlled))

    ON/OFF controlled indoor unit (2.5HP)

    Time

    Stable room temperature

    Cooling

    Suct

    ion

    air t

    emp.

    Note: The graph shows the data, measured in a test room assuming actual heating load. The thermostat can

    control stable room temperature at 0.5C from set point.

    Comfort guaranteed at all times

    3434

    16Constant and high air discharge temperature

  • db(A) Perceived loudness Sound

    0 Treshold of hearing -

    20 Extremely soft Rustling leaves

    40 Very soft Quiet room

    60 Moderately loud Normal conversation

    80 Very loud City traffic noise

    100 Extremely loud Symphonic orchestra

    120 Threshold of feeling Jet taking off

    Daikin indoor units

    Low indoor unit operation sound level Daikin indoor units have very low sound operation levels, down to 19dB(A), making them ideal for sound sensitive areas as hotel bedrooms, etc

    emura

    VRV SERIES (DAIKIN indoor unit (PID controlled))

    ON/OFF controlled indoor unit (2.5HP)

    Back -up Function In the event of a compressor malfunction another compressor or outdoor unit will take over in order to maintain 8 hour interim capacity, allowing time for maintenance or repair while comfort remains guaranteed.

    Single outdoor unit with multiple compressors

    Multi outdoor unit system

    FXZQ-A

    Connectable to VRV IV and VRV III-S heat pump Connectable to all VRV heat pumps

    19dB(A) 25.5dB(A)

    34 35

    BEN

    EFIT

    S

    34

    Constant and high air discharge temperature

  • 1 Contact your local dealer for more information and restrictions

    Flexible piping design The long piping lengths, high level differences and small refrigerant piping allows for a design with little limitations and leaving maximum space for lettable space.

    Benefits for design offices and consultantsMaximum flexibilityMeeting and exceeding legal requirements

    VRV IV example

    Total piping length 1000m

    Longest length actual (Equivalent) 165m (190m)

    Longest length after first branch 90m1

    Level difference between indoor and outdoor units

    90m1

    Level difference between indoor units 30m

    1 Contact your local dealer for more information and restrictions 2 In case outdoor unit is located below indoor units

    165m

    Act

    ual p

    ipin

    g le

    ngth

    40m

    (90m

    1 ) L

    evel

    diff

    eren

    ce b

    etw

    een

    indo

    or a

    nd o

    utdo

    or u

    nits

    30m

    Lev

    el d

    iffer

    ence

    bet

    wee

    n in

    door

    uni

    ts

    90m

    pip

    ing

    leng

    th a

    fter f

    irst b

    ranc

    h

    Wide operation range The VRV system can be installed practically anywhere. VRV outdoor units operate in cooling mode between -20C and +46C outdoor ambient and between -25C and +15.5C in heating mode.

    46C 15.5C-20C -25C

    With the technical cooling function, the operation range in cooling of the heat recovery system is extended from -5C to -20C 1, making it perfect for integrating server rooms.

    Cooling mode Heating mode

    3636

  • Night quiet mode For areas where there are stringent limitations to sound levels the outdoor unit sound level can be reduced, to meet the requirement.

    Maximum flexibilityMeeting and exceeding legal requirements

    Example for VRV IV heat pump, factory setting.

    Peak in the outdoor temperature

    100%

    50%

    8 hrs

    58 dBA

    50dBA

    45 dBA

    10 hrs

    Step 1: max. - 8dB (10HP)

    Night mode STARTS Night mode ENDS

    Night mode

    Step 1: 50dB

    Step 2: 45dBStep 2: max. - 13dB (10HP)Capacity* %Load %

    Operation Sound dBA

    Multiple tenants, one outdoor unit The multi tenant function ensures that the entire VRV system does not shut down when the main power supply of an indoor is switched off. This means that the indoor units main fuse can be turned off when a part of the building is closed, is being serviced,

    No structural reinforcement necessary Thanks to the vibration-free and sufficient light construction of the outdoor units, floors do not need to be reinforced, reducing the overall cost of the building when compared to a chiller.

    Indoor installation The VRV optimised fan blade shape increases output and reduces pressure loss. Together with the high ESP setting (up to 78pa), it makes VRV outdoor units ideal for indoor installation using ducts.

    Indoor installation leads to less piping length, lower installation costs, increased efficiency and better visual aesthetics.

    ESP up to

    78pa

    max. 398kg for a 20HP unit

    Heating mode

    in holiday

    operation

    operation

    in service

    36 37

    BEN

    EFIT

    S

    36

  • Benefits forinstallers Fast installation and commissiong Easy servicing

    Top quality - Only brazed connections All flange and flare connections inside the unit have been replaced by brazing connections to ensure improved refrigerant containment. Also the connection of the outdoor in the main pipe is brazed.

    Phased installation Installation of the VRV system can be implemented floor by floor, so that sections of the building can be put into use very quickly, or enabling the air conditioning system to be commissioned and operated in stages, rather than on final completion of the project.

    Installation floor by floor

    Under construction

    XX

    VRV system

    Compact design The compact design of the outdoor units is sufficient to allow them to be taken up to the top of a building in a commercial elevator, overcoming site transportation problem, particularly when outdoor units need to be installed on each floor.

    Brazing

    Flare or flange

    3838

  • Fast installation and commissiong Easy servicing

    Automatic charging & testing

    Connect bottle to VRV & active automatic

    charging function

    Calculate extra refrigerant volume

    Filling procedure stops automatically:

    close valves

    Connect first bottle on VRV & start filling process

    Check on regular times weight scale to check weight of

    refrigerant

    Stop manually the VRV filling procedure & close valves

    Manual

    Automatic

    1 2 3 4

    1 2

    Push button on the PCB

    After charging pushing the test operation button initiates a check on the wiring, shut off valves, sensors and refrigerant volume.

    Planned installation64 m refrigerant piping

    calculation: 2.2kg extra refrigerant required

    Real installation 76 m refrigerant piping

    2.7kg extra refrigerant required in reality

    0.5 kg

    10% undercharged

    up to 25% capacity loss

    33% more energy use

    Ecient use of time

    Optimal charge = optimal eciency

    Daikin Unified REFNET piping The unified Daikin REFNET piping system is especially designed for simple installation.

    Compared to regular T-joints, where refrigerant distribution is far from optimal, the Daikin REFNET joints have specifically been designed to optimise refrigerant flow.

    Daikin Europe N.V. advises only to use Daikin REFNET piping system.

    REFNET joint T-jointAttached insulators

    for REFNET jointAttached insulators for REFNET header

    REFNET headerREFNET joint

    If the temperature drops below 20C* manual charging is necessary.* 10C for heat pump for cold regions* Not available for VRV Classic and VRV IV W-series

    Did you know

    38 39

    BEN

    EFIT

    S

    38

  • Refrigerant Recovery Function When an indoor unit or outdoor needs to be replaced in case of malfunction the refrigerant can be easily drained from the system, making servicing easier.

    Automatic refrigerant containment checkPerform the refrigerant containment check remotely via Intelligent Touch Manager, when it is most convenient for you, preventing an on-site visit. At the same time increase your customer satisfaction because there is no disruption to the air conditioning during business hours.Next to remote checking, the refrigerant containment check function can also be activated on-site via a push button on the PCB.

    Connect to customer site via internet or 3G after working hours

    Check the report once the check has been done

    Remotely set the time and start the refrigerant

    containment check

    When activating the refrigerant containment check, the unit switches into cooling mode and duplicates certain reference conditions based on memory data. The result indicates whether or not refrigerant leakage has occurred.

    The refrigerant volume of the complete system is calculated for the following data: Outdoor temperature Reference system temperatures Reference pressure temperatures Refrigerant density Types and number of indoor units

    Not available on VRVIII-S or in combination when one or more RA indoor units, hydroboxes, are connected

    Easy compliance to F-gas regulation

    4040

  • Easy wiring - Super Wiring System Simplied wiring Shared use of wiring between indoor units, outdoor units and centralised remote control Easy retrofit of centralised remote control Impossible to make incorrect connections thanks to non polarity wiring

    Cross wiring checkThe cross wiring check facility warns operatives of connection errors in inter unit wiring and piping.

    Auto Address Setting FunctionAllows wiring between indoor and outdoor units, as well as group control wiring of multiple indoor units, to be performed without the bothersome task of manually setting each address.

    Installer: I dare to assert that in a record time (construction took only four months) we have built the most energy ecient cinema in The Netherlands, and even in Europe.

    Large cinemaCinemeerse

    12 x VRV heat recovery 8HP outdoor units

    air handling units with VAV (70,000m3/h) connected to CO2 sensors

    40 41

    BEN

    EFIT

    S

    40

  • 4242

    VRVOutdoor

    VRV IV Heat

    recovery

    VRV IV heat pump

    with continous heating

    VRV IV heat pump

    without continous

    heating

    VRV III-S VRV III-C VRV Classic

    Replacement VRV IV

    heat pump

    Replacement VRV III Heat

    recovery

    Water cooled VRV IV

    p 44 p 50 p 50 p 56 p 60 p 64 p 66 p 66 p 72

    Variable Refrigerant Temperature Continuous heating (heat accumulating element) -Continuous heating ( alternate defrost) -VRV congurator 7 segment indicator Automatic refrigerant charge Refrigerant containment check Night quiet mode -Manual low noise function -

    Connectable to stylish indoor units (Daikin Emura, Nexura) Connectable to LT hydrobox for hot water Connectable to HT hydrobox for hot water Full inverter compressors Gas cooled PCB 4 side heat exchanger -Reluctance brushless DC compressor

    Sine wave DC inverter

    DC fan motor -

    E-pass heat exchanger -

    I demand function Manual demand function

    systems

  • 42 43

    VRV

    IV H

    EAT

    RECO

    VERY

    42

    Overview of functions

    VRV IV Heat

    recovery

    VRV IV heat pump

    with continous heating

    VRV IV heat pump

    without continous

    heating

    VRV III-S VRV III-C VRV Classic

    Replacement VRV IV

    heat pump

    Replacement VRV III Heat

    recovery

    Water cooled VRV IV

    p 44 p 50 p 50 p 56 p 60 p 64 p 66 p 66 p 72

    Variable Refrigerant Temperature Continuous heating (heat accumulating element) -Continuous heating ( alternate defrost) -VRV congurator 7 segment indicator Automatic refrigerant charge Refrigerant containment check Night quiet mode -Manual low noise function -

    Connectable to stylish indoor units (Daikin Emura, Nexura) Connectable to LT hydrobox for hot water Connectable to HT hydrobox for hot water Full inverter compressors Gas cooled PCB 4 side heat exchanger -Reluctance brushless DC compressor

    Sine wave DC inverter

    DC fan motor -

    E-pass heat exchanger -

    I demand function Manual demand function

  • VRV IV heat recovery

    VRV IV standards:

    Variable refrigerant temperature Customize your VRV for best seasonal eciency & comfort

    Continuous heating The new standard in heating comfort

    VRV congurator Software for simplified commissioning, configuration

    and customisation

    7 segment indicator Automatic refrigerant charge Refrigerant containment check Night quiet mode Manual low noise function Full inverter compressors Gas cooled PCB 4 side heat exchanger Reluctance brushless DC compressor Sine wave DC inverter DC fan motor E-pass heat exchanger I demand function Manual demand function

    Air curtainBiddle Air curtain for VRV (CYV)

    Hot waterLow temperature hydrobox High temperature hydrobox

    22

    Indoor unitsVRV type indoor units

    VentilationHeat Reclaim ventilation (VAM/VKM)

    Fresh air indoor units (FXMQ-MF)AHU connection kit

    For detailed explanation of these functions refer to VRV IV technologies tab

    Control systems

    4444

  • 7 segment indicator Automatic refrigerant charge Refrigerant containment check Night quiet mode Manual low noise function Full inverter compressors Gas cooled PCB 4 side heat exchanger Reluctance brushless DC compressor Sine wave DC inverter DC fan motor E-pass heat exchanger I demand function Manual demand function

    Did you know

    that re-using energy by heat recovery can lead to savings up to 10, meaning for 1 unit of electricity? This means huge savings in running costs and CO2 emissions.

    1087654321

    0 20 40 60 80 100

    COPIdeal situation when heating and cooling

    Only cooling50% heating50% cooling Only heating

    Free heat and hot water production Until now most commercial buildings have individual systems for cooling, heating, hot water etc. leading to big energy waste.An integrated heat recovery system reuses heat from oces, server rooms etc. to warm other areas or create hot water.

    free hot water and heatingHeating

    22

    Cooling

    22

    Hot Water

    Extracted heat delivers

    Improved efficiency In heat recovery operation the VRV IV is up to 15% more ecient. In full load operation the seasonal eciency is ecient even up to 28% better compared to VRV III thanks to Variable Refrigerant Temperature.

    T amb

    Load

    Improved mix mode refrigerant control Up to 15%

    more ecient

    Hot waterLow temperature hydrobox High temperature hydrobox

    44 45

    VRV

    IV H

    EAT

    RECO

    VERY

    44

    More free heat Daikin 3-pipe technology needs less energy to recover heat, meaning signicant better eciency during heat recovery mode. Our system can recover the heat at low condensing temperature because it has dedicated gas, liquid and discharge pipes.

    In a 2-pipe system gas and liquid travel as a mixture so the condensing temperature needs to be higher in order to separate the mixed gas and liquid refrigerant. The higher condensing temperature means more energy is used to recover heat resulting in lower eciency.

    Pres

    sure

    Enthalpy

    Power input Daikin

    Power input

    2-pipe system

    Condensing 55C

    Condensing 45C

  • Free combination of outdoor units Freely combine outdoor units to optimise for small footprint, continuous heating, highest efficiency or any other combination.

    Flexible piping design

    165m

    Act

    ual p

    ipin

    g le

    ngth

    40m

    (90m

    1 ) L

    evel

    diff

    eren

    ce b

    etw

    een

    indo

    or a

    nd o

    utdo

    or u

    nits

    30m

    Lev

    el d

    iffer

    ence

    bet

    wee

    n in

    door

    uni

    ts

    90m

    max

    imum

    Total piping length 1000m

    Longest length actual (Equivalent) 165m (190m)

    Longest length after first branch 90m1

    Level difference between indoor and outdoor units

    90m1

    Level difference between indoor units 30m

    1 Contact your local dealer for more information and restrictions 2 In case outdoor unit is located below indoor units

    More efficient due to lower pressure drop

    0 50 100 m

    Disturbed refrigerant ow in large gas pipe on 2-pipe system leading to bigger pressure drop

    110%

    105%

    100%

    95%

    90%

    85%

    80%

    Smooth refrigerant ow in 3-pipe system thanks to 2 smaller gas pipes leading to higher energy eciency

    3-pipe VRV H/R

    2-pipe system

    N

    S

    Maximum comfort A VRV heat recovery system allows simultaneous cooling and heating. For hotel owners it means a perfect environment for guests as

    they can freely choose between cooling or heating. For oces it means a perfect working climate both for tenants

    facing south and north.

    4646

  • Fully redesigned BS boxes

    No need to cut the pipe before brazing(for indoor units smaller or equal to 5.6 kW (50 class))

    Faster installation thanks to open connection

    Cut and braze the pipe(for indoor units bigger or equal to 7.1 kW (63 class))

    Time saving!

    Maximum design flexibility and installation speed

    Compact & light to install Ideal for remote rooms as no drain piping needed Allows integration of server rooms thanks to

    technical cooling function Connect up to 250 class unit (28kW) Allows multi tenant applications

    Up to 70% smaller and 66% lighter than previous range Faster installation thanks to a reduced number of brazing points and wiring All indoor units connectable to one BS box Less inspection ports needed compared to installing single BS boxes Up to 16 kW capacity available per port Connect up to 250 class unit (28kW) by combining 2 ports No limit on unused ports allowing phased installation

    Single port Multi port: 4 6 8 10 12 16

    BS1Q10,16,25A BS4Q14A BS6,8Q14A BS10,12Q14A BS16Q14A

    Unique range of single and multi BS boxes for flexible and fast design Major reduction in installation time thanks to wide range, compact size and light weight multi BS boxes

    Maximum comfort at all times Thanks to the VRV BS box, all indoor units which are not switching from cooling to heating or vica versa continue to provide heating or cooling. This is because our heat recovery system does not need to equalize pressure over the entire system after a change-over.

    46 47

    VRV

    IV H

    EAT

    RECO

    VERY

    46

  • Specications

    REYQ-T 8 10 12 13 14 16 18 20System Outdoor unit module 1 REYQ8T REYQ10T REMQ5T REYQ12T REYQ8T REYQ14T REYQ16T REYQ8T REYQ18T REYQ8T REYQ20T REYQ8T

    Outdoor unit module 2 REMQ5T REMQ5T REYQ8T REYQ10T REYQ12TCapacity range HP 8 10 10 12 13 14 16 16 18 18 20 20Continuous heating v v v v vCooling capacity Nom kW 22.4 28.0 28.0 33.5 36.4 40.0 45.0 44.8 50.0 50.4 56.0 55.9Heating capacity Nom kW 22.4 28.0 28.0 33.5 36.4 40.0 45.0 44.8 50.0 50.4 56.0 55.9Heating capacity Max. kW 25.0 31.5 32.0 37.5 41.0 45.0 50.0 50.0 56.0 56.5 63.0 62.5Power input - 50Hz Cooling Nom. kW - - - - - - - -

    Heating Nom. kW - - - - - - - -EER - - - - - - - -ESEER - - - - - - - -COP - - - - - - - -Maximum number of connectable indoor units 64 (1)Indoor index connection

    Min 100 125 125 150 162.5 175 200 200 225 225 250 250Nom 200 250 250 300 325 350 400 400 450 450 500 500Max 260 325 325 390 422.5 455 520 520 585 585 650 650

    Dimensions Unit hxwxd mm 1685x930x765 - 1685x930x765 - 1685x1240x765 - 1685x1240x765 - 1685x1240x765 -Weight Unit kg 198 205 - 205 - 319 319 - 329 - 329 -Fan Air ow rate Cooling Nom m3/min 162 175 - 185 - 223 260 - 251 - 261 -Sound power level Cooling Nom dBA 78 79 81 81 81 81 86 81 86 82 88 83Sound pressure level Cooling Nom dBA 58 58 61 61 61 61 64 61 65 61 66 63Operation range Cooling Min~max CDB -20(2) / -5~43

    Heating Min~max CWB -20~15.5Water production

    Space cooling Min~max CDB 8~43Space heating Min~max CWB -20~20 / 24 (2)Domestic hot waterMin~max

    CWB -20~43

    Refrigerant Type R-410APiping connection liquid OD mm 9.5 9.5 9.5 12.7 12.7 12.7 12.7 12.7 15.9 15.9 15.9 15.9

    gas OD mm 19.1 22.2 22.2 28.6 28.6 28.6 28.6 28.6 28.6 28.6 28.6 28.6discharge gas OD mm 15.9 19.1 19.1 19.1 19.1 22.2 22.2 22.2 22.2 22.2 28.6 28.6total piping length system m 1000

    Power supply Phase/Frequency/Voltage Hz/V 3N~ / 50 / 380-415Current - 50Hz Maximum fuse amps (MFA) A 20 25 40 32 40 32 40 40 40 50 50 50

    OUTDOOR UNIT MODULE REMQ5TDimensions Unit hxwxd mm 1685x930x765Weight Unit kg 198Fan Air ow rate m3/min 162Sound power level Cooling Nom dBA 78Sound pressure level Cooling Nom dBA 58Operation range Cooling Min~max CDB -20(2) / -5~43

    Heating Min~max CWB -20~15.5Water production Space cooling 8~43

    Space heating -20~20 / 24 (2)Domestic hot water -20~43

    Refrigerant Type R-410APower supply Phase/Frequency/Voltage Hz/V 3N~ / 50 / 380-415Current - 50Hz Maxiimum fuse amps (MFA) A 20

    REYQ-T 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54System Outdoor unit module 1 10 8 12 12 12 16 16 16 8 10 10 12 14 16 16 16 18

    Outdoor unit module 2 12 16 14 16 18 16 18 20 10 12 16 16 16 16 16 18 18Outdoor unit module 3 20 18 16 16 16 16 18 18 18

    Capacity range HP 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54Continuous heating V V V V V V V V V V V V V V V V VCooling capacity Nom kW 61.5 67.4 73.5 78.5 83.5 90 95.0 101.0 106.4 111.5 118.0 123.5 130.0 135 140.0 145.0 150Heating capacity Nom kW 61.5 67.4 73.5 78.5 83.5 90 95.0 101.0 106.4 111.5 118.0 123.5 130.0 135 140.0 145.0 150Heating capacity Max. kW 69.0 75.0 82.5 87.5 93.5 100 106.0 113.0 119.5 125.0 131.5 137.5 145.0 150 156.0 162.0 168Power input - 50Hz Cooling Nom. kW - - - - - - - - - - - - - - - - -

    Heating Nom. kW - - - - - - - - - - - - - - - - -EER - - - - - - - - - - - - - - - - -ESEER - - - - - - - - - - - - - - - - -COP - - - - - - - - - - - - - - - - -Maximum number of connectable indoor units 64 (1)Indoor index connection

    Min 275 300 325 350 375 400 425 450 475 500 525 550 575 600 625 650 675Nom 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 1250 1300 1350Max 715 780 845 910 975 1040 1105 1170 1235 1300 1365 1430 1495 1560 1625 1690 1755

    Piping connection liquid OD mm 15.9 15.9 19.1 19.1 19.1 19.1 19.1 19.1 19.1 19.1 19.1 19.1 19.1 19.1 19.1 19.1 19.1gas OD mm 28.6 34.9 34.9 34.9 34.9 34.9 34.9 41.3 41.3 41.3 41.3 41.3 41.3 41.3 41.3 41.3 41.3discharge gas OD mm 28.6 28.6 28.6 28.6 28.6 28.6 28.6 28.6 34.9 34.9 34.9 34.9 34.9 34.9 34.9 34.9 34.9total piping lenght system m 1000

    Current - 50Hz Maximum fuse amps (MFA) A 63 63 63 63 80 80 80 80 100 100 100 100 100 125 125 125 125

    VRV IV heat recovery - REYQ-T

    1 Actual number of connectable indoor units depends on the indoor unit type (VRV indoor, hydrobox, etc.) and the connection ratio restriction for the system (50%

  • BS1Q10A BS1Q16A BS1Q25APower input Cooling Nom. kW 0.005

    Heating Nom. kW 0.005Maximum number of connectable indoor units 6 8Maximum capacity index of connectable indoor units 15 < x 100 100

  • VRV IV heat pumpVRV IV heat pump

    VRV IV standards:

    Variable refrigerant temperature Customize your VRV for best seasonal eciency & comfort

    Continuous heating The new standard in heating comfort

    VRV congurator Software for simplified commissioning,

    configuration and customisation

    7 segment indicator Automatic refrigerant charge Refrigerant containment check Night quiet mode Manual low noise function Full inverter compressors Gas cooled PCB 4 side heat exchanger Reluctance brushless DC compressor Sine wave DC inverter DC fan motor E-pass heat exchanger I demand function Manual demand function

    Air curtainBiddle Air curtain for VRV (CYV)

    Hot waterLow temperature hydrobox

    22

    Indoor unitsVRV type indoor units

    Residential type indoor units (such as Daikin Emura)

    VentilationHeat Reclaim ventilation (VAM/VKM)

    Fresh air indoor units (FXMQ-MF)AHU connection kit

    For detailed explanation of these functions refer to VRV IV technologies tab

    Control systems

    5050

  • Combine VRV indoor units with stylish indoor units (Daikin Emura, Nexura, )

    FVXG-KNexura

    FXFQ-AVRV indoor unit

    FXSQ-PVRV indoor unit

    FVXG-KNexura

    Connectable indoor units

    BPMKS box needed to connect RA indoors to VRV IV (RYYQ-T and RXYQ-T)

    15 CLASS 20 CLASS 25 CLASS 35 CLASS 42 CLASS 50 CLASS 60 CLASS 71 CLASS

    Daikin Emura Wall mounted unit FTXG20LW FTXG20LSFTXG25LWFTXG25LS

    FTXG35LWFTXG35LS

    FTXG50LWFTXG50LS

    Wall mounted unit CTXS15K FTXS20K FTXS25K FTXS35KCTXS35K FTXS42K FTXS50K FTXS60G FTXS71G

    Nexura Floor standing unit FVXG25K FVXG35K FVXG50K

    Floor standing unit FVXS25F FVXS35F FVXS50F

    Flexi type unit FLXS25B FLXS35B9 FLXS50B FLXS60B

    Wide range of indoor units

    FTXG-LWDaikin Emura

    BPMKS967B2

    Hot waterLow temperature hydrobox

    VRV

    IV H

    EAT

    PUM

    P

    50 5150

  • VRV IV proven in practice:

    40% more ecient

    Results: up to 60% less energy consumed The results of the trial showed that the new VRV IV system consumed much less energy, particularly when cooling, compared with the VRV III system in some cases up to 60% less. When heating, savings were an average of 20%.

    The Unterhachingtrial demonstrates how VRV IV heat pump technology uses a renewable energy source air - to provide a complete and environmentally sustainable solution for heating, cooling, and ventilation in commercial environments. The trial also shows that businesses can only identify and control energy wastage through careful and intelligent monitoring of climate control systems, a service which Daikin can offer.

    A field trial at a German fashion chain store demonstrated how the innovative features of VRV IV have improved energy efficiency dramatically over previous models.

    5252

    Average daily consumption

    during working hours in kWh

    Energy saving in %

    Energy use VRV III in 2012 in kWh Energy use VRV IV in 2013 in kWh Energy saving in %

    Trendline energy use VRV III Trendline energy use VRV IV Trendline energy saving

    220

    210

    200

    190

    180

    170

    160

    150

    140

    130

    120

    110

    100

    90

    80

    70

    60

    50

    40

    30

    20

    10

    70

    60

    50

    40

    30

    20

    10

    0%-2 -1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26

  • Total piping length 1000m

    Longest length actual (Equivalent) 165m (190m)

    Longest length after rst branch 90m1

    Level dierence between indoor and outdoor units 90m1

    Level dierence between indoor units 30m

    1 Contact your local dealer for more information and restrictions 2 in case outdoor unit is located below indoor units

    Free combination of outdoor units Freely combine outdoor units to optimise for small footprint, continuous heating, highest efficiency or any other combination

    Flexible piping design

    165m

    Act

    ual p

    ipin

    g le

    ngth

    40m

    (90m

    1 ) L

    evel

    diff

    eren

    ce b

    etw

    een

    indo

    or a

    nd o

    utdo

    or u

    nits

    30m

    Lev

    el d

    iffer

    ence

    bet

    wee

    n in

    door

    uni

    ts

    90m

    max

    imum

    VRV

    IV H

    EAT

    PUM

    P

    52 5352

    Energy use VRV III in 2012 in kWh Energy use VRV IV in 2013 in kWh Energy saving in %

    Trendline energy use VRV III Trendline energy use VRV IV Trendline energy saving

  • Specications

    OUTDOOR UNIT 8 10 12 14 16 18 20Capacity range HP 8 10 12 14 16 18 20Cooling capacity Nom. kW 22.4 28.0 33.5 40.0 45.0 50.0 56.0Heating capacity Nom. / Max. kW 22.4 / 25.0 28.0 / 31.5 33.5 / 37.5 40.0 /45.0 45.0 / 50.0 50.0 / 56.0 56.0 / 63.0

    Power input - 50HzCooling Nom. kW 5.21 7.29 8.98 11.0 13.0 14.7 18.5Heating Nom. / Max. kW 4.75 / 5.5 6.29 / 7.38 7.77 / 9.1 9.52 / 11.2 11.1 / 12.8 12.4 / 14.4 14.5 / 17.0

    EER 4.30 3.84 3.73 3.64 3.46 3.40 3.03ESEER 6.37 (2) / 7.53 (3) 5.67 (2) / 7.20 (3) 5.50 (2) / 6.96 (3) 5.31 (2) / 6.83 (3) 5.05 (2) / 6.50 (3) 4.97 (2) / 6.38 (3) 4.42 (2) / 5.67 (3)COP Nom. / Max. 4.72 / 4.54 4.45 / 4.27 4.31 / 4.12 4.20 / 4.02 4.05 / 3.91 4.03 / 3.89 3.86 / 3.71Maximum number of connectable indoor units 64 (1)

    Indoor index connection

    Min. 100 125 150 175 200 225 250Nom. 200 250 300 350 400 450 500Max. 260 325 390 455 520 585 650

    Dimensions Unit HeightxWidthxDepth mm 1,685x930x765 1,685x1,240x765Weight Unit RYYQ/RXYQ/RXYQQ kg 261 / 187 / 187 268 / 194 / 194 364 / 305 / 305 398 / 314 / 314Fan Air ow rate Cooling Nom. m3/min 162 175 185 223 260 251 261Sound power level Cooling Nom. dBA 78 79 81 86 88Sound pressure level Cooling Nom. dBA 58 61 64 65 66

    Operation rangeCooling Min.~Max. CDB -5~43Heating Min.~Max. CWB -20~15.5

    Refrigerant Type R-410A

    Piping connectionsLiquid OD mm 9.52 12.7 15.9Gas OD mm 19.1 22.2 28.6Total piping length System Actual m 1,000

    Power supply Phase/Frequency/Voltage Hz/V 3N~ / 50 / 380-415Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 40 50

    OUTDOOR SYSTEM 22 24 26 28 30 32 34 36

    SystemOutdoor unit module 1 10 8 12 16Outdoor unit module 2 12 16 14 16 18 16 18 20Outdoor unit module 3 -

    Capacity range HP 22 24 26 28 30 32 34 36Cooling capacity Nom. kW 61.5 67.4 73.5 78.5 83.5 90.0 95.0 101.0Heating capacity Nom. / Max. kW 61.5 / 69.0 67.4 / 75.0 73.5 / 82.5 78.5 / 87.5 83.5 / 93.5 90.0 / 100.0 95.0 / 106.0 101.0 / 113.0

    Power input - 50HzCooling Nom. kW 16.3 18.2 20.0 22.0 23.7 26.0 27.7 31.5Heating Nom. / Max. kW 14.06 / 16.5 15.85 / 18.3 17.29 / 20.3 18.87 / 21.9 20.17 / 23.5 22.2 / 25.6 23.5 / 27.2 25.6 / 29.8

    EER 3.77 3.70 3.68 3.57 3.52 3.46 3.43 3.21ESEER 5.58 (2) / 7.07 (3) 5.42 (2) / 6.81 (3) 5.39 (2) / 6.89 (3) 5.23 (2) / 6.69 (3) 5.17 (2) / 6.60 (3) 5.05 (2) / 6.50 (3) 5.01 (2) / 6.44 (3) 4.68 (2) / 6.02 (3)COP Nom. / Max. 4.37 / 4.18 4.25 / 4.10 4.25 / 4.06 4.16 / 4.00 4.14 / 3.98 4.05 / 3.91 4.04 / 3.90 3.95 / 3.79Maximum number of connectable indoor units 64 (1)

    Indoor index connection

    Min. 275 300 325 350 375 400 425 450Nom. 550 600 650 700 750 800 850 900Max. 715 780 845 910 975 1,040 1,105 1,170

    Piping connectionsLiquid OD mm 15.9 19.1Gas OD mm 28.6 34.9 41.3Total piping length System Actual m 1,000

    Current - 50Hz Maximum fuse amps (MFA) A 63 80

    VRV IV heat pump with continuous heating - RYYQ8-54T VRV IV heat pump without continuous heating - RXYQ8-54T

    5454

  • OUTDOOR SYSTEM 38 40 42 44 46 48 50 52 54

    SystemOutdoor unit module 1 8 10 10 12 14 16 16 16 18Outdoor unit module 2 10 12 16 18Outdoor unit module 3 20 18 16 18

    Capacity range HP 38 40 42 44 46 48 50 52 54Cooling capacity Nom. kW 106.0 112.0 118.0 124.0 130.0 135.0 140.0 145.0 150.0Heating capacity Nom. / Max. kW 106.0 / 120.0 112.0 / 125.0 118.0 / 132.0 124.0 / 138.0 130.0 / 145.0 135.0 / 150.0 140.0 / 156.0 145.0 /162.0 150.0 / 168.0

    Power input - 50HzCooling Nom. kW 31.0 33.3 35.0 37.0 39.0 40.7 42.4 44.1Heating Nom. / Max. kW 25.54 / 29.9 26.46 / 30.9 28.49 / 33.0 29.97 / 34.7 31.72 / 36.8 33.30 / 38.4 34.6 / 40.0 35.9 / 41.6 37.2 / 43.2

    EER 3.42 3.61 3.54 3.51 3.46 3.44 3.42 3.40ESEER 5.03 (2) / 6.36 (3) 5.29 (2) / 6.74 (3) 5.19 (2) / 6.65 (3) 5.17 (2) / 6.62 (3) 5.13 (2) / 6.60 (3) 5.05 (2) / 6.50 (3) 5.02 (2) / 6.46 (3) 4.99 (2) / 6.42 (3) 4.97 (2) / 6.38 (3)COP Nom. / Max. 4.15 / 4.01 4.23 / 4.05 4.14 / 4.00 4.14 / 3.98 4.10 / 3.94 4.05 / 3.91 4.05 / 3.90 4.04 / 3.89 4.03 / 3.89Maximum number of connectable indoor units 64 (1)

    Indoor index connection

    Min. 475 500 525 550 575 600 625 650 675Nom. 950 1,000 1,050 1,100 1,150 1,200 1,250 1,300 1,350Max. 1,235 1,300 1,365 1,430 1,495 1,560 1,625 1,690 1,755

    Piping connectionsLiquid OD mm 19.1Gas OD mm 41.3Total piping length System Actual m 1,000

    Current - 50Hz Maximum fuse amps (MFA) A 100 125

    OUTDOOR UNIT MODULE FOR RYYQ-T COMBINATIONS RYMQ8T RYMQ10T RYMQ12T RYMQ14T RYMQ16T RYMQ18T RYMQ20TDimensions Unit HeightxWidthxDepth mm 1,685x930x765 1,685x1,240x765Weight Unit kg 188 195 309 319Fan Air ow rate Cooling Nom. m3/min 162 175 185 223 260 251 261Sound power level Cooling Nom. dBA 78 79 81 86 88Sound pressure level Cooling Nom. dBA 58 61 64 65 66

    Operation rangeCooling Min.~Max. CDB -5~43Heating Min.~Max. CWB -20~15.5

    Refrigerant TypePower supply Phase/Frequency/Voltage Hz/V 3N~ / 50 / 380-415Current - 50Hz Maximum fuse amps (MFA) A 20 25 32 40 50

    (1) Actual number of connectable indoor units depends on the indoor unit type (VRV indoor, Hydrobox, RA indoor, etc.) and the connection ratio restriction for the system (50%

  • Optimised design for small capacities

    VRV III-S heat pump

    Automatic refrigerant charge Refrigerant containment check Night quiet mode Manual low noise function Full inverter compressors Reluctance brushless DC compressor Sine wave DC inverter DC fan motor E-pass heat exchanger I demand function Manual demand function

    Air curtainBiddle Air curtain for VRV (CYV)

    Control systems

    22

    Indoor unitsVRV type indoor units

    Residential type indoor units(such as Daikin Emura, ...)

    VentilationHeat Reclaim ventilation (VAM/VKM)

    AHU connection kit

    5656

  • VRV III-S heat pump

    Space saving design The VRVIII-S is slimmer and more compact, resulting in significant savings in installation space.

    Footprint Approx. 60% Reduction

    Volume Approx. 70% Reduction

    900mm

    1,68

    5 m

    m

    1,34

    5 m

    m

    930mm

    765m

    m

    320mm

    Wide range of indoor units Connect VRV units

    * VRV indoor units and stylish indoor units cannot be combined.

    FCQG-F

    FBQ-C

    BPMKS967B2

    FTXG-JA - Daikin Emura

    FVXG-KNexuraFVXG-KNexura

    FBQ-C

    BPMKS967B2

    or stylish indoor units

    FXAQ-P

    FXFQ-A

    FXSQ-P

    FXZQ-A

    FXAQ-P

    new

    Connectable indoor units15 CLASS 20 CLASS 25 CLASS 35 CLASS 42 CLASS 50 CLASS 60 CLASS 71 CLASS

    Round ow cassette FCQG35F FCQG50F FCQG60FFully at cassette FFQ25C FFQ35C FFQ50C FFQ60CSmall concealed ceiling unit FDBQ25BSlim concealed ceiling unit FDXS25F FDXS35F FDXS50F9 FDXS60FConcealed ceiling unit with inverter driven fan FBQ35C8 FBQ50C8 FBQ60C8

    Daikin Emura Wall mounted unit FTXG20LW FTXG20LSFTXG25LWFTXG25LS

    FTXG35LWFTXG35LS

    FTXG50LWFTXG50LS

    Wall mounted unit CTXS15K FTXS20K FTXS25K FTXS35KCTXS35K FTXS42K FTXS50K FTXS60G FTXS71G

    Ceiling suspended unit FHQ35C FHQ50C FHQ60CNexura Floor standing unit FVXG25K FVXG35K FVXG50KFloor standing unit FVXS25F FVXS35F FVXS50FFlexi type unit FLXS25B FLXS35B9 FLXS50B FLXS60B

    VRV

    III-S

    HEA

    T PU

    MP

    56 5756

  • VRV indoors connected

    Stylish indoors connected

    Total piping length 300m 250m

    Longest length actual (Equivalent) 150m (175m)

    Minimum length between outdoor unit and rst branch - 5m

    Minimum piping length between BP and indoor unit - 2m

    Maximum piping length between BP and indoor unit - 15m

    Longest length after rst branch 40m 40m

    Level dierence between indoor and outdoor units 50m (40m1) 30m

    Level dierence between indoor units 15m 15m

    1 Nominal cooling capacities are based on: indoor temperature: 27CDB, 19CWB, outdoor temperature: 35C, equivalent refrigerant piping: 5m, level difference: 0m.

    2 Nominal heating capacities are based on: indoor temperature: 20CDB, outdoor temperature: 7CDB, 6CWB, equivalent refrigerant piping: 5m, level difference: 0m

    0 1 2 3 4 5

    Heating

    Cooling

    High COP values A major feature of VRVIII-S is its exceptional energy efficiency. The system achieves high COPs during both cooling and heating operation by the use of refined components and functions. 3.99 1

    4.55 2

    Flexible piping design

    150m

    Act

    ual p

    ipin

    g le

    ngth

    50m

    Lev

    el d

    iffer

    ence

    bet

    wee

    n in

    door

    and

    out

    door

    uni

    ts

    15m

    Lev

    el d

    iffer

    ence

    bet

    wee

    n in

    door

    uni

    ts

    40m

    max

    imum

    1 Outdoor unit in lowest position

    5858

  • Specications

    VRVIII-S Heat pump - single phase (P8V1), three phase (P8Y1)OUTDOOR UNIT RXYSQ4P8V1 RXYSQ5P8V1 RXYSQ6P8V1 RXYSQ4P8Y1 RXYSQ5P8Y1 RXYSQ6P8Y1Capacity range HP 4 5 6 4 5 6Cooling capacity Nom. kW 12.6 14.0 15.5 12.6 14.0 15.5 Heating capacity Nom. kW 14.2 16.0 18.0 14.2 16.0 18.0 Power input - 50Hz Cooling Nom. kW 3.24 3.51 4.53 3.33 3.61 4.66

    Heating Nom. kW 3.12 3.86 4.57 3.21 3.97 4.70EER 3.89 3.99 3.42 3.78 3.88 3.33COP 4.55 4.15 3.94 4.42 4.03 3.83Maximum number of connectable indoor units 8 (1) / 8 (2) 10 (1) / 9 (2) 12 (1) / 9 (2) 8 (1) / 8 (2) 10 (1) / 9 (2) 12 (1) / 9 (2)Indoor index connection

    Min. 50 62.5 70 50 62.5 70Nom. -Max. 130 162.5 182 130 162.5 182

    Dimensions Unit HeightxWidthxDepth mm 1,345x900x320Weight Unit kg 120Fan Air ow rate Cooling Nom. m3/min 106Sound power level Cooling Nom. dBA 66 67 69 66 67 69Sound pressure level

    Cooling Nom. dBA 50 51 53 50 51 53Heating Nom. dBA 52 53 55 52 53 55

    Operation range Cooling Min.~Max. CDB -5~46Heating Min.~Max. CWB -20~15.5

    Refrigerant Type R-410APiping connections

    Liquid OD mm 9.52Gas OD mm 15.9 (1) / 19.1 (2) 19.1 15.9 (1) / 19.1 (2) 19.1Total piping length System Actual m 300 (1) / 115 (2) 300 (1) / 135 (2) 300 (1) / 145 (2) 300 (1) / 115 (2) 300 (1) / 135 (2) 300 (1) / 145 (2)

    Power supply Phase/Frequency/Voltage Hz/V 1N~/50/220-240 3N~/50/380-415Current - 50Hz Maximum fuse amps (MFA) A 32.0 16.0

    (1) In case VRV indoor units are connected (2) In case RA indoors are connected

    1

    2

    3

    2 Smooth air inlet bell mouth and aero spiral fanThese features assist in significantly reducing noise. Guides are added to the bell mouth intake to reduce turbulence in the air flow generated by fan suction. The aero spiral fan features fan blades with bent blade edges, further reducing turbulence.

    Conventional NewEscaping edges are sucked in by the bent blade edges, reducing overall turbulence.

    Aero spiral fan blade tips

    1 Super aero grilleThe spiral shaped ribs are aligned with the direction of discharge flow in order to minimise turbulence and reduce noise.

    Advanced technologies

    Evaporative capacity can be raised by taking super cooling just before the electronic expansion valve

    By the SCe- bridge circuit, cooling and heating attain the improvement in COP

    SCe-Bridge Circuit

    Evaporative-capacity has been improved by adopting the SCe-Bridge Circuit circuit.

    Current Evaporative-

    capacity

    3 e-Bridge circuit Prevents accumulation of liquid refrigerant in the condenser.

    This results in more efficient use of the condenser surface under all conditions and leads in turn to better energy efficiency. Increased evaporative capacity stems from the newly developed refrigeration circuit, the SCe-bridge circuit, which adds super cooling prior to the expansion cycle. By adopting this circuit, the COPs in both coolingand heating have been drastically improved.

    VRV

    III-S

    HEA

    T PU

    MP

    58 5958

  • VRV heat pump optimised for heating

    VRVIII-C Automatic refrigerant charge Refrigerant containment check Night quiet mode Manual low noise function Reluctance brushless DC compressor Sine wave DC inverter DC fan motor E-pass heat exchanger I demand function Manual demand function

    VRV heat pump optimised for heating

    VRVIII-C

    Air curtainBiddle Air curtain for VRV (CYV)

    22

    Indoor unitsVRV type indoor units

    Control systems

    VentilationHeat Reclaim ventilation (VAM/VKM)

    Fresh air indoor units (FXMQ-MF)AHU connection kit

    6060

  • Wide heating operation range VRVIII-C has a standard operation range down to -25 CWB outdoor ambient in heating and can also provide cooling down to - 5 CDB outdoor ambient.

    Outdoor Temp.

    heat

    ing

    capa

    city

    Stable heating capacity VRVIII-C has a stable heating capacity, even in low ambients, making it suitable for single source heating. The heating capacity is 130% in comparison with the standard VRV heating capacity under similar conditions

    -25 -20 -15 -10 -5 0 5 10

    Heating capacity 10HP outdoor unitOutdoor temp. (CWB)

    (kW) 35

    30

    25

    20

    15

    10

    5

    0

    standard heat pump

    COP

    4.00

    3.00

    2.00

    1.00

    0.00-25 -20 -15 -10 -5 0 5 10

    Standard h

    eat pump

    Outdoor temp. (WB)

    COP for a 10HP unit

    High COP at low ambients The use of two stage compression technology results in improved energy saving performance at low ambients, with a COP of more than 3.0 at -10C outdoor ambient for the entire range.

    43CDB-5C

    Outdoor Temp.

    -20CWB 15.5CStandard VRV

    -25CWBVRVIII-C

    Heating mode Cooling mode

    VRV

    III-C

    HEA

    T PU

    MP

    60 6160

  • Total piping length 500m

    Longest length actual (Equivalent) 165m (190m)

    Longest length between outdoor unit and function unit

    10m

    Longest length after rst branch 40m (90m1)

    Level dierence between indoor and outdoor units

    50m (40m2)

    Level dierence between indoor units 30m

    1 Contact your local dealer for more information and restrictions 2 In case outdoor unit is located below indoor units

    Flexible piping design

    165m

    Act

    ual p

    ipin

    g le

    ngth

    50m

    Lev

    el d

    iffer

    ence

    bet

    wee

    n in

    door

    an

    d ou

    tdoo

    r uni

    ts15

    m L

    evel

    diff

    eren

    ce b

    etw

    een

    in

    door

    uni

    ts

    90m

    max

    imum

    30

    25

    20

    15

    60

    50

    40

    30

    20

    10

    0

    -10

    -20

    C

    positie blauwe lijnen:X +10

    -5 0 5 6 10 14 15 20

    Hi