Eco Line ES100M36-ENGLISH · Electrical characteristics Module diagram Junction box Module...

1
Electrical characteristics Module diagram Junction box Module dimension (mm) Weight (kg) Number of bypass diodes & type Electrical parameters may vary by -5% to +5% 36 (4x9) Water proof IP67, 1000 VDC 1190X540X35 8.80 2 pcs bypass diodes Packing information 1 pcs/ctn 100Wp 18.0V 5.56A 22.32V 5.9A 1000VDC 0 to +3% Eco Line ES100M36 -0.36%/K 0.05%/K -0.44%/K 44±2°C -40~+85°C Product code Maximum power (Pmax) Voltage at Pmax (Vmp) Current at Pmax (Imp) Open-circuit voltage (Voc) Short-circuit current (Isc) Temperature coefficient of Voc Temperature coefficient of Isc Temperature coefficient of power Normal operating cell temperature Operating temperature Maximum system voltage Power tolerance *Measured at standard test conditions: irradiance 1,000 W/m², air mass 1.5 spectrum, temperature 25°C SolarXXL Group GmbH Ohmstrasse 2, 63225 Langen/Hessen, Germany [email protected] www.solarxxl.com www.enjoysolar.de Eco Line ES100M36 Characteristics Current(A) Voltage(V) 200W/m² 400W/m² 600W/m² 800W/m² 1000W/m² Cell temp. 25°C 0 0 1 2 3 4 5 6 7 8 9 5 10 15 20 25 Cells 6.5mm * Dimensions in brackets are in millimeters. Unit: mm

Transcript of Eco Line ES100M36-ENGLISH · Electrical characteristics Module diagram Junction box Module...

Page 1: Eco Line ES100M36-ENGLISH · Electrical characteristics Module diagram Junction box Module dimension (mm) Weight (kg) Number of bypass diodes & type Electrical parameters may vary

Electrical characteristics

Module diagram

Junction box

Module dimension (mm)

Weight (kg)

Number of bypass diodes & type

Electrical parameters may vary by -5% to +5%

36 (4x9)

Water proof IP67, 1000 VDC

1190X540X35

8.80

2 pcs bypass diodes

Packing information 1 pcs/ctn

100Wp

18.0V

5.56A

22.32V

5.9A

1000VDC

0 to +3%

Eco Line ES100M36

-0.36%/K

0.05%/K

-0.44%/K

44±2°C

-40~+85°C

Product code

Maximum power (Pmax)

Voltage at Pmax (Vmp)

Current at Pmax (Imp)

Open-circuit voltage (Voc)

Short-circuit current (Isc)

Temperature coe�cient of Voc

Temperature coe�cient of Isc

Temperature coe�cient of power

Normal operating cell temperature

Operating temperature

Maximum system voltage

Power tolerance

*Measured at standard test conditions: irradiance 1,000 W/m², air mass 1.5 spectrum, temperature 25°C

SolarXXL Group GmbHOhmstrasse 2, 63225 Langen/Hessen, Germany [email protected] www.enjoysolar.de

Eco Line ES100M36

Characteristics

Curr

ent(

A)

Voltage(V)

200W/m²

400W/m²

600W/m²

800W/m²

1000W/m² Cell temp. 25°C

00

1

2

3

4

5

6

7

8

9

5 10 15 20 25

Cells

6.5mm