Eaton Flow
Transcript of Eaton Flow
2
In-Line Flow Con-trol Operation
Application of In-Line Flow Control
Oil flow entering the In-line Flow Control passes through the fixed orifice in theplunger, then out the cross holes in the plunger and sleeve. The oil then flowsaround the sleeve and out the Flow Control. When the oil flows through the fixedorifice it creates a pressure differential across the fixed orifice. As oil flow volumeincreases the pressure differential increases. This pressure differential causes theplunger to move, compressing the spring and gradually closing off the cross holes.The spring rate and cross hole design causes a restriction that regulates the predeter-mined flow rate of the flow Control. This Flow Control is regulated flow in onedirection and free flow in the opposite direction. The Flow Control is flow sensitiveand not pressure sensitive. The flow rate is factory set and is not field adjustable.
Hydrostatic Limited Slip Differential - Used to prevent over speed of Hydraulic Motorswhen two motors are teed together. By installing one in each motor work port, it willcontrol maximum flow in both directions.
Motor Over speed from external over run - Used in motor outlet port to prevent anexternal load from causing the motor to over speed.
Controlled Flow to Hydraulic circuit - Used in multiple circuits to control maximumflow to or from a single hydraulic circuit.
Speed Control for Multiple motors connected in parallel - Used to control flow rate toindividual motors to allow all motors to turn at the same speed regardless of load onmotor.
Pattern
Sleeve
Plunger FixedOrifice
Cartridge
Cross Hole
Inlet —RegulatedFlow
Inlet —FreeFlow
Inline Flow Control Valve
Operation andApplication
3
Inline Flow Control Valve
Specifications andDimension Data
Product Number Regulated Flow32604-ABR 53 LPM [14 GPM]32604-ABW 80 LPM [21 GPM]32604-ABV 106 LPM [28 GPM]
OrderingInformation
Other Settings Available — Contact your Eaton Representative.
Max. Operating Pressure 345 Bar [5000 PSI]Max. Surge Pressure 379 Bar [5500 PSI]Weight 1 Kg [2.5 lb]Material — All SteelFlow Tolerance ± 5,7 LPM [1.5 GPM]
1432604—ABR
139 [5.50]
22,4 [.88] 3 [.12]
15 [.59]
47,8 [1.88]
Regulated Flow (GPM)
Product Number LocationWork Port —A
1-1/16 —12 SAE37° Flare
Work Port —B1-1/16 —12 SAE
A B
Reverse FlowControlled Flow
Copyright Eaton Corporation, 1992, 1994, and 1996All Rights ReservedPrinted in USAForm No. 11-504
Inline Flow Control Valve
Performance Curves
[ 0]
[ 5]
[10]
[15]
[25]
[30]
0 34 69 103 138 172 207 241 276 310 345
100
80
60
40
20
0
120LPM [GPM]
0 [500] [1000] [1500] [2000] [2500] [3000] [3500] [4000] [4500] [5000]
32604-ABR
32604-ABW
32604-ABV
[20]
Inlet Pressure Bar [PSI]
Flow
[ 0]
[ 5]
[10]
[15]
[25]
[30]
0714212834
100
80
60
0
120LPM [GPM]
0[100][200][300][400][500]
32604-ABV
[20]
Inlet Pressure Bar [PSI]
Flow
32604-ABR
32604-ABW
40
20
Eaton CorporationHydraulics Division15151 Hwy. 5Eden Prairie, MN 55344Telephone 612/937-9800Fax 612/937-7130
Eaton Ltd.Hydraulics DivisionGlenrothes, FifeScotland, KY7 4NWTelephone 01-592-771-771Fax 01-592-773-184
Eaton GmbHHydraulics ProductsAm Schimmersfeld 740880 Ratingen, GermanyTelephone 02102-406-830Fax 02102-406-800
ISO-9001 CERTIFICATED FIRMDET NORSKE VERITAS INDUSTRY BV, THE NETHERLANDS
ACCREDITED BYTHE DUTCH COUNCILFOR CERTIFICATION
Reg. No. 24
Quality System CertifiedProducts in this catalog are manufacturedin an ISO-9001-certified site.
http://www.eaton.com