Easy Reader - Jainam Biomedical
Transcript of Easy Reader - Jainam Biomedical
Features
üFully automatic.
üEasy Windows operation system with touch screen or mouse, large LCD display.
ü8-channel optical fiber system enables 5 seconds reading for the whole plate.
üBichromatic measurement, calculation modes include ABS, Cut-off, Curve, linear, log and exponent regression.
üRandom positive control and negative control setting.
üMulti-assay feature enables up to 12 different assays on one plate.
üLarge memory to store up to 100 test protocols and 10000 results.
üPowerful QC function: Westgard rules, Levey Jennings plot.(optional)
üPlate shaking feature.
üAuto power-on self-check feature.
üAdditional lamp saving feature.
üMultiform result output including patient comprehensive report.
üAbility to communicate with PC for data management. (optional)
üEasy maintenance design.
Fully Automatic
Control Accuracy PerformanceTechnology
Reliable Result Multi-assay feature Ability to communicate
Easy ReaderMicroplate Reader
www.alere.com
TUVSUD
ISO13485CERTIFIED
CALL TOLL FREE NO. :
1800-102-9595
Easy ReaderMicroplate Reader
www.alere.com
Corporate Office:
Alere Medical Pvt. Ltd.No: 404, 4th Floor, BPTP Park Centra, NH-8, Opp. 32nd Milestone,Gurgaon-122 001, Haryana, IndiaOffice No.: +91-124-4569000 • Fax : +91-124-4569011 E-mail: [email protected]
Main Specifications
Main Menu
Calibration
Report
Name: Susan Sex: Female Age: 25 Dept: xxx
Date: 20/10/2003 Sample: 05 Bed No: 006 Sender: xxx
Program Full name Result Unit Diagnosis Reference range
HIV
HbsAg
HbsAb
T3
0.163
0.283
0.634
3.374
s/co-
s/co-
s/co-
Neg-
Neg-
Neg-
(0.000-1.000)
(0.000-1.000)
(0.000-1.000)
Operator: Checker:
0.000-4.000Abs
0.001Abs(displayed). 0.0001Abs(calculated)
Halogen lamp, 8V/50W
405,450,492,630nm, 4 more filters optional
+ 1nm
8nm
ABS, %ABS, cut-off,linear, point to point,log,
+ 1% or + 0.005A
5secs for 96 well plate (Single wavelength)
Shaking time and speed adjustable
100 tests, up to 10000 test results
RS-232, PSTN (optional)
6" LCD
Touch panel or mouse
External printer (optional)
8KG
460 x 330 x 200
AC 110V-220V+ 10%, 50-60Hz
exponent, power regression
Photometric Range
Resolution
Light Source
Wavelenghs
Wavelengh Accuracy
Band Width
Calculation Method
Accuracy
Rdading Speed
Shaking Plate
Memory
Interface
Display
Input
Output
Net Weight
Dimensions LXWXH (mm)
Power Supply
Plate setting
Programming
Patient data setting
001 002 003
1 2 3 4 5 6 7 8 9 10 11 12
ABCDEFGH
Sample Blank NC PC STD QC CLR
Program ABS
New Select all Clear all Start Cancel
Program
Full name
HbsAg
Antigen
450
None
Absorbance
>> Cancel
Blanks 0.050Double sample
Calibaration mode
Second wavelength
First wavelength
Respent
Date 2003-06-09 Sample No. 001
Age
Sex Male Female Unknow
Dept
Bed ID Sender
Operator
ID
xxx
Ok Cancel
xxx
xxx006
008
Input patient information
Name Sustan 25
Calculation Absorbance
1.100(A)
0.550
0.0000.000 1.500 3.000(g/1)
Print Cancel
Program:Demo
Calculation mode:Reg
Test Program Report Remote
System Information Log Power off