E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source...

34
E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle demonstration of the undulator method - undulator basics - transmission polarimetry - GEANT4 polarization upgrade results & conclusions E166: Polarized Positrons & Polarimetry K. Peter Schüler (DESY) - on behalf of the E166 Collaboration JPOS 09 at Jefferson Lab 25-27 March 2009

Transcript of E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source...

Page 1: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

E166: Polarized Positrons & PolarimetryK. Peter Schüler

• ILC: - why polarized positrons - e+ source options - undulator source scheme• E166 - proof-of-principle demonstration of the undulator method - undulator basics - transmission polarimetry - GEANT4 polarization upgrade• results & conclusions

E166: Polarized Positrons & PolarimetryK. Peter Schüler (DESY) - on behalf of the E166 Collaboration

JPOS 09 at Jefferson Lab25-27 March 2009

Page 2: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

ILC: why polarized positrons?

2JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

• SLC as precursor of the ILC very successfully employed polarized electrons, but not polarized positrons.

• What does the ILC gain from polarized positrons?

longitudinally polarized beams:

• can enhance or suppress processes!

Page 3: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

why polarized positrons?

3JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

effective polarization in s-channel (e+e- γ/Z) annihilation:

• positron polarization can significantly increase precision in measurement of ALR

Page 4: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

4JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

why polarized positrons?

Supersymmetry: Selectron Pair Production

• positron polarization is required for separation of RR from LR pairs

Page 5: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

5JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

why polarized positrons?

• can effectively enhance or suppress processes

• improved signal/background ratio

• higher effective polarization and precision in ALR asymmetry

• unique understanding of non-standard couplings

• explore new physics (e.g. extra dim.) with transverse beam pol.

G. Moortgat-Pick et al., Physics Reports 460 (2008) 131-243

CERN-PH-TH-2005-036, SLAC-PUB-11087, arXiv: hep-ph/0507011

Page 6: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

e+ source options for the ILC

6

existing/proposed positron sources:

← ILC

3 Concepts:

large amount ofcharge req‘d !

• ‚conventional‘• laser Compton based • undulator-based

JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

Page 7: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

undulator source

7

PRO:• photoprod. in thin target 0.4 X0 Ti-alloy lower e+ beam emittance• less energy deposition in target (1/5) and AMD (1/10)• less neutron induced activation (1/16)• no multiplexing & accumulation req‘d• polarized positrons

CON:• need high-energy electron drive beam (coupled e+/e- operation)• long undulator (150-300 m) req‘d

positron beam profile

JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

Page 8: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

undulator source scheme for ILC

8JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

• undulator is chosen baseline scheme for the positron source (although initially at less than full length)• expect initial e+ polarization of ~ 30%• Compton based e+ source has alternative status

Page 9: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

E166 – proof of principle demonstrationof the undulator method

9JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

Page 10: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

undulator basics

10

E166 ILC (RDR) electron beam energy (GeV) 46.6 150 field (T) 0.71 0.86 period (mm) 2.54 11.5 K value 0.17 0.92 photon energy 0

max (MeV) 7.9 10.0 beam aperture (mm) 0.89 5.85 active length (m) 1 147 M (no. of periods) 394 12800

JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

Page 11: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

undulator basics

11

E166 Photon Spectrum E166 Photon Polarization

Spectrum: Angular Distribution: Polarization:

first harmonic (dominating) expressions:

E166 Photon Yield: = no. of photons per high-energy beam electron

0max = 7.9 MeV

JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

Page 12: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

The E166 Experiment

12

2004/2005 setup and checkout

Oct. 2005 4 weeks of data taking

JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

Page 13: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

E166 experimental setup

13

C1 – C4: photon collimationA1, A2: aerogel detectorsS1, S2: silicon detectorsGCAL: Si/W-calorimeter

DM: electron beam dump magnetsT1: g e+ prod. target (0.2 X0 W)T2: e+ g reconv. target (0.5 X0 W)P1: e+ flux monitor (Silicon)CsI: Cesium Iodide calorimeterSL: solenoid lensJ: movable jaws

4 – 8 MeV

< 8 MeV

JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

Page 14: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

E166 photo gallery

14JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

Page 15: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

transmission polarimetry

15

1. Compton Transmission Polarimetry for Low-Energy Photons relies on spin dependence of Compton effect in magnetized iron:

2. Positron Polarimetry: (a) transfer e+ polarization to photon via brems/annihilation process (b) then infer e+ polarization from measured photon pol. as in method 1.

JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

Page 16: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

16

analyzer magnets: overview

active volumePhoton Analyzer: 50 mm dia. x 150 mm longPositron Analyzer: 50 mm dia. x 75 mm long

Pe ≈ 0.07

ΔPe/Pe ~ 0.03

electron polarization of the iron:

M = (B–B0)/0 magnetization n = electron densityμB = Bohr magneton g‘ = magneto-mechanical factor

JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

Page 17: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

17

analyzer magnets

CsI-Detector

e+ Analyzer

Pickup Coils

e+ Analyzer Analyzer

JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

Page 18: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

18

electron polarization of the iron

Pe/Pe ~ 2%

JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

Pe ~ 0.07

Page 19: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

19

Simulations

JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

GEANT4 upgrade for spin-dependent e/m processes:

• gammas: - gamma conversion - Compton scattering - photo-electric effect• electrons & positrons: - multiple scattering - ionization - bremsstrahlung• polarization tranfer - Y e+/e- - e+/e-Y • polarimetry - Compton scattering - Bhabha scattering - Moller scattering - positron annihilation in flight

e+/e- spectra at production target

e+/e- polarization & analyzing power

Page 20: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

20

photon asymmetries

detector asymmetry (%) measured predicted S2 (silicon) 3.88 E 0.12 E0.63 3.1 A2 (aerogel) 3.31 E 0.06 E0.16 3.6 GCAL (Si/W-calo) 3.67 E 0.07 E0.40 3.4

• reasonable agreement with simulation results based on theoretical undulator polarization spectrum and detector response functions • but no detailed spectral shape analysis possible

JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

Page 21: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

21

positron measurements

• exp. asymmetry of ~1% expected in CsI• large background from e- beam halo req‘s equal amount of undulator „on“ and „off“ statistics • normalization to P1 detector avoids false asymmetries from flip-correlated beam shifts

JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

Page 22: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

energy deposition in CsI crystals

22

• good signal/background separation in central crystal • background from e- beam halo hitting the undulator• undulator on/off measurements taken on alternating machine pulses for effective background subtraction

undulator on: signal + backgroundundulator off: background

JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

Page 23: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

23

positron asymmetries

JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

Page 24: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

24

positron asymmetries

JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

Page 25: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

results: beam polarization

25

= analyzing power from simulations = electron polarization of the iron

JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

Page 26: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

26

conclusions• successful demonstration of the undulator method• undulator functioned as predicted• successful polarimetry of low-energy and e+ • confirmed expected γ e+ spin-transfer mechanism • measured high positron polarization with ~ 85% max.

JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

Page 27: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

27JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

• long paper (66 pages) about to be submitted to NIM

• PRL 100, 210801 (2008), G. Alexander et al.:

published results

Page 28: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

28JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

why polarized positrons?Transverse Beam Polarization:

• Gravity in Extra Dimensions: expect significant asymmetric deviations from SM in the azimuthal distributions

T. G. Rizzo, JHEP 0302 (2003) 008 [arXiv:hep-ph/0211374];

JHEP 0308 (2003) 051 [arXiv:hep-ph/0306283].

Page 29: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

29

conventional positron source (as used for SLC at SLAC)

PRO: established technology (although not at req‘d level)CON: pushing technical limits of target materials; req‘s multiple targets and beamlines; very high activation levels no polarization option

thick W-Re target:strong multiple scattering,less efficient e+ capture

JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

Page 30: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

30

spin and magnetization

g‘ = magneto-mechanical factor: obtained from Einstein - de Haas type experiments, related to gyromagnetic ratio: γ = (g‘/2) ∙ (e/m)

the principle … and its ultimate implementation (Scott 1962) g‘ = 1.919 ± 0.002 for pure iron i.e. orbital effects contribute about 4%

Note: g‘ = 2 Ms / M = 1 (pure spin magnetization) γ = e/m g‘ = 1 Ms / M = 0 (pure orbit magnetization) γ = ½ (e/m)

JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

Page 31: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

31

field distribution modeling(Vector Fields OPERA-2d)

R = 0 mm

1015

22.5

Bz (T)

Z (mm)

longitudinal field distribution: Bz (R,Z)field drops gradually towards the ends: Leff / L < 1

center

end

20

5

JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

Page 32: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

32

field distribution in 2d(Vector Fields OPERA-2d)

longitudinal field distribution: Bz (R,Z)(shown for one quadrant)

R (mm)

Z (mm)

JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

Page 33: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

33

flux measurements: measure voltage transients in pickup coils upon current reversals

Positron Analyzer (-60 +60 amps)

voltage transient

JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler

Page 34: E166: Polarized Positrons & Polarimetry K. Peter Schüler ILC: - why polarized positrons - e+ source options - undulator source scheme E166 - proof-of-principle.

34

flux and field measurements: results

Note: polarimetry was always done at full saturation over the central region (±60A)

Z = 0 (center)

JPOS 09 at Jefferson Lab

25-27 March 2009

E166: Polarized Positrons & Polarimetry

K. Peter Schüler