Dynatel - multimedia.3m.com · 1K ohm to 9.9K 10K ohms to 99.9K ohms 100K ohms to 999K ohms 1M ohm...

8
3 Dynatel Qualification Test Set 950ADSL2 Plus Rugged and portable for ADSL2+ testing and measurement.

Transcript of Dynatel - multimedia.3m.com · 1K ohm to 9.9K 10K ohms to 99.9K ohms 100K ohms to 999K ohms 1M ohm...

Page 1: Dynatel - multimedia.3m.com · 1K ohm to 9.9K 10K ohms to 99.9K ohms 100K ohms to 999K ohms 1M ohm to 9.9M ohms 10M ohms to 30M ohms 1 ohm ohms 10 ohms 100 ohm 1K ohm 100K ohms 1M

3Dynatel™

Qualification Test Set 950ADSL2 Plus

Rugged and portable for ADSL2+ testing and measurement.

Page 2: Dynatel - multimedia.3m.com · 1K ohm to 9.9K 10K ohms to 99.9K ohms 100K ohms to 999K ohms 1M ohm to 9.9M ohms 10M ohms to 30M ohms 1 ohm ohms 10 ohms 100 ohm 1K ohm 100K ohms 1M

3m™ dynatel™ qualification test set 950adsl2 plus

The heat is on to provide high-speed Internet access and enhanced broadband services over existing copper networks. 3M’s next generation Dynatel™ Qualification Test Set 950ADSL2 Plus has all the right features to ensure the successful installation and maintenance of ADSL2+ service. The 3M™ Dynatel™ Qualification Test Set 950ADSL2 Plus is a cost-

effective solution ideal for technicians providing both POTS testing

and verification of ADSL2+ modem connectivity.

rugged, reliaBle design

The Dynatel test sets are housed in a light-weight, hand-held case

designed for ease-of-handling and portability. Each unit weighs less

than 2.5 pounds with the rechargeable battery pack included. The

display clearly provides test results and measurements including bin

graphs and data rates.

Test set in soft carry case.

The right tool for the job.

2

Page 3: Dynatel - multimedia.3m.com · 1K ohm to 9.9K 10K ohms to 99.9K ohms 100K ohms to 999K ohms 1M ohm to 9.9M ohms 10M ohms to 30M ohms 1 ohm ohms 10 ohms 100 ohm 1K ohm 100K ohms 1M

Back/Undo

Speaker Volume Dialing

Resistance Measurement

Voltage Measurement

Tool Box

Opens Length

Contrast Down

PowerON/OFF

Backlight ON/OFF

Auto Test / Menu Down

AC Tests / Menu Up

Send Tone

ADSL Connection Test Save Results

Ping Test

Loop Current

Select or Change Setup

Keypad functions

Contrast Up

Choose Option or Measurement Mode

sample screen

3m™ dynatel™ qualification test set 950adsl2 plus

3

Page 4: Dynatel - multimedia.3m.com · 1K ohm to 9.9K 10K ohms to 99.9K ohms 100K ohms to 999K ohms 1M ohm to 9.9M ohms 10M ohms to 30M ohms 1 ohm ohms 10 ohms 100 ohm 1K ohm 100K ohms 1M

4

pots and adsl tests

The Dynatel Qualification Test Set 950ADSL2 Plus conducts multiple metallic tests independently

or as part of the Autotest function. Tests include CO and foreign voltage, insulation and loop

resistance, longitudinal balance and loss & noise. Autotest results can be saved and uploaded

for record storage and later analysis. The tester can also generate tones up to 2.2MHz for loss

measurements.

ADSL2+ active testing include performance measurements including data rate up/down, max

rate, attenuation etc., as well as error measurements such as FEC, CRC and HEC with bin

graph capture to analyze data transfer performance. The 950ADSL2 Plus can also ping to an

ISP to measure response time. In addition, ADSL2+ test results can be saved and uploaded for

record storage or later analysis.

product featuresTESTS PERFORMED

Volts – AC and DC

Loop Current

Resistance Test

Soak Test

Ground Resistance

Opens

Loss and Noise

Longitudinal Balance

Pulse and DTMF Dialing

Load Coils

POTS Autotest

Precision Tones to 2.2Mhz

ADSL2+/ADSL2/ADSL Connectivity

Ping Testing

FEATURES

Backlit LCD

Water resistant attachment for test leads and DC charger

Rechargeable NiMH battery

Serial upload to PC

Storage for 100 ADSL2+ results

Storage for 10 POTS results

3m™ dynatel™ qualification test set 950adsl2 plus

Page 5: Dynatel - multimedia.3m.com · 1K ohm to 9.9K 10K ohms to 99.9K ohms 100K ohms to 999K ohms 1M ohm to 9.9M ohms 10M ohms to 30M ohms 1 ohm ohms 10 ohms 100 ohm 1K ohm 100K ohms 1M

5

general specificationsSize 60 mm high x 100 mm wide x 200 mm long

Weight Less than 1.5 lb. with battery

Battery Ni-MH: 2100 mAhr – shrink wrap pack, user replaceable through access door on bottom of unit

Battery life 8 hours standby (backlight off) + 20 full ADSL2+ qualification tests of 2 minute durationSeparate charger / AC/DC adapter connects to the unit through external power jackAuto shutoff after 5 minutes with no activity, except during charging

Display 64 x 128 pixel, 57 mm x 31 mm viewing area with LED backlight

Test leads Red, black and green leads. 1.5 meters long. Connected to unit via standard jacks.

Breakdown voltage 360 VDC, 250 VAC

Operating temperature -18°C to 60°C except for ADSL2+ and Battery Charger Functions0°C to 60°C ADSL Functions0°C to 50°C battery charger operation

Humidity 0 to 95% non-condensing

Shock Will survive 3 drops from 1 meter

Regulatory CE/FCC per: CISPR 11:2003 / EN55011:2003, Class A, Group 1FCC CFR 47, Part 15, Subpart B – Class AEN61326:1997+A1:1998+A2:2001 ( IEC 61326:2002 )

Dialing DTMF or Pulse Dialing – 10 number storage

ADSL2+ Test Storage 100 sets of results, each identified with an alpha numeric labelStored results can be viewed in the test set

POTS test storage 10 sets of results, each identified with a 10-digit numeric identifier Stored results can be viewed in the test set.

POTS autotest Autotest will run the following tests: V (T,R,Gnd), mA, Ground Resistance, Ohms (T,R,Gnd), Opens (T,R,Gnd), Load Coil Count, Noise, PI, LB and Loss (up to 10 voiceband frequencies)

Languages English, French or alternative 2nd language subject to availability

Serial port Adapter cable connected to the test leads can be used for connecting the unit to a PCThe serial connection supports the following:• Upload of test results to the PC• Remote configuration of ADSL and Ping parameters from a PC• Field software updates

3m™ dynatel™ qualification test set 950adsl2 plus

Page 6: Dynatel - multimedia.3m.com · 1K ohm to 9.9K 10K ohms to 99.9K ohms 100K ohms to 999K ohms 1M ohm to 9.9M ohms 10M ohms to 30M ohms 1 ohm ohms 10 ohms 100 ohm 1K ohm 100K ohms 1M

6

pots measurement specificationsFUNCTION RANGE RESOLUTION ACCURACY TEST LEADS

AC voltage 0 to 250 VAC (input resistance = 1M Ohm ± 5% )

± 1 V ± 2% R-T, R-G, T-G

DC voltage 0 to 250 VDC (input resistance = 1M Ohm ± 5% )

± 1 V ± 2% R-T, R-G, T-G

Loop Current (DC) 0 to ±110 mA 1 mA ±2mA R-T (Impedence= 430Ω)

Resistance 0 ohm to 999 ohms 1K ohm to 9.9K10K ohms to 99.9K ohms100K ohms to 999K ohms1M ohm to 9.9M ohms10M ohms to 30M ohms

1 ohm ohms 10 ohms100 ohm1K ohm100K ohms1M ohm

± 5 ohm ± 3% ± 3%± 3%± 3%± 3%± 10%

R-T, R-G, T-G

Voltage compensation for foreign voltage conditions

Loop loss -50 to +10 dBm 200 to 5000 Hz

1 dB ±1 dB R-T (Impendence = 600Ω)

Frequency during loss, single frequency only and levels greater than -45 dBm

200 to 5,000 Hz 1 Hz ± 3 Hz ± 0.2% R-T

Noise metallic with C-message weighting**

0 to 60 dBrnc 1 dB ±2 dB R-T (Impedence = 600Ω)

Noise to ground with C-message weighting**

40 to 100 dBrnc 1 dB ±2 dB R & T-G (Zin=100KW)

Note: Available only with a C-Message filter, for Psophometric version contact Communication Markets Division, 3M Telecommunications.

Opens 0 to 9,999 ft. 10,000 to 99,999 ft(0 to 9,999 m)(10,000 to 30,000m)

1 ft. 100ft(1 m)(100m)

± 20 ft. ±5% +/- 5%(± 6m, ±5%)(+/- 5%)

Ring, Tip, Mutual

Longitudinal balance 0 to 65 dB 1 dB ±2 dB T,R-G

Ground resistance 0 to 50 Ω 1 Ω ± 3 Ω

Load coils Count 0,1,2,3,4 or >4 coils +/- 1 coil

Note: First load must be >3000’ from unit and 3000’ of cable must extend beyond the last load coil for an accurate count.

Precision tone Frequency: 404, 1004, 2804 (preset) (Source impedence = 600 ohms +/- 5% )

Amplitude 0 ± 0.5 dBm R-T

Frequency: 8000 Hz – 2.2Mhz (user settable) +/- 10% Source impedence = 100 ohms +/- 5% 577 Hz intermittent trace tone

Amplitude 0 ± 0.5 dBm

Amplitude 5V P-P

R-T

Notes: * Percent of reading ** C-message specification has additional frequency dependent tolerance. Refer to “Subscriber Loop Transmission Test Set Specification”, Bell System PUB 55020, January 1982.

3m™ dynatel™ qualification test set 950adsl2 plus

Page 7: Dynatel - multimedia.3m.com · 1K ohm to 9.9K 10K ohms to 99.9K ohms 100K ohms to 999K ohms 1M ohm to 9.9M ohms 10M ohms to 30M ohms 1 ohm ohms 10 ohms 100 ohm 1K ohm 100K ohms 1M

3m™ dynatel™ qualification test set 950adsl2 plus

adsl/adsl2+ measurement specificationsADSL/ADSL2+ Standards T1.413 i2 (ANSI)

G.992.2 (G.LITE)G.992.1 (G.DMT)G.992.3 (G.DMT.bis/ADSL2)G.992.5 (ADSL2plus)Support for Annexes A, B, and LLine impedance 100 ohms nominal

FUNCTION MEASUREMENT

ADSL2+ Status (up/down) Fast rate Interleaved rateMaximum attainable bit ratePowerMarginAttenuationCapacity

ADSL2+ Information (up/down) FEC (forward error correction count)CRC Error countHEC ATM Header Errors countSEF Severe Errors Frame countLOS Loss of signal count

Bin Graph

ADSL2+ Alarms LOS: Loss of Signal > 127LOF: SEF > 127LCD: NCD or LCD > 127

pots and adsl testsPing capability is supported via an internal communication protocol as listed.

IP address assignment DHCP per RFC 2131

IPCP per RFC 1332

Point-to-Point Protocol PPP over ATM (PPPoA)

PPP over Ethernet (PPPoE)

Authentication PAP

CHAP

Ping Connection time +/- 10 mS

7

Page 8: Dynatel - multimedia.3m.com · 1K ohm to 9.9K 10K ohms to 99.9K ohms 100K ohms to 999K ohms 1M ohm to 9.9M ohms 10M ohms to 30M ohms 1 ohm ohms 10 ohms 100 ohm 1K ohm 100K ohms 1M

3Communication Markets Division 3M Telecommunications6801 River Place Blvd.Austin, TX 78726-9000800/426 8688Fax 800/626 0329www.3MTelecommunications.com

Litho in USA.80-6113-1560-9© 3M 2006. All Rights Reserved.Please Recycle

3M and Dynatel are trademarks of 3M.

product contents and ordering information3M PART NO. DESCRIPTION UPC

950ADSL2-PLUS-SN 950ADSL2 Plus ADSL2+ test set with single nail leads CE100710744

950ADSL2-PLUS-BON 950ADSL2 Plus ADSL2+ test set with bed-of-nails leads CE100710751

950ADSL2PLUS 950E-ADSL2 Plus test set with bed-of-nails leads-psophometric (European)

CE100712385

1188* 1188 cigarette lighter adapter for 965AMS/950ADSL2 Plus 80611316227

950-NIMH NIMH battery pack, 949ADSL/950ADSL/950ADSL2 PLUS CE100700745

950ADSL2PLUS-ADAP 950ADSL2 Plus, 12VDC charger CE100707260

950ADSL2PLUS-CABLE 950ADSL2 Plus, serial cable CE100707252

1143 1143 lead, test green 965DSP/950ADSL2 Plus 80610864375

1144 1144 lead, test black/red 965DSP/950ADSL2 Plus 80610864359

950-CASE Soft carrying case 949/950 CE100700737

*optional accessory

To order, call 800/426 8688. For more information, please contact your local 3M representative.

3m™ dynatel™ qualification test set 950adsl2 plus

Important NoticeAll statements, technical information, and recommendations related to 3M’s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M’s current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M.

Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture for a period of 12 months from the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M’s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any loss or damage arising from this 3M product, whether indirect, special, incidental or consequential regardless of the legal theory asserted.