DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit...

26
DynAMo Operations Suite (DOS) Software Change Notice 1 DynAMo Operations Suite (DOS) R211.2 Software Change Notice Document ID: DOS R211.2 Revision Date: December 27, 2017

Transcript of DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit...

Page 1: DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit Repository (LR) is a software component in BFlex OM Pro suites as well as DOS applications

DynAMo Operations Suite (DOS) Software Change Notice 1

DynAMo Operations Suite (DOS) R211.2

Software Change Notice

Document ID: DOS R211.2 Revision Date: December 27, 2017

Page 2: DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit Repository (LR) is a software component in BFlex OM Pro suites as well as DOS applications

DynAMo Operations Suite (DOS) Software Change Notice 2

Notices and Trademarks

© Honeywell International Sàrl 2017. All Rights Reserved.

While this information is presented in good faith and believed to be accurate, Honeywell disclaims the

implied warranties of merchantability and fitness for a particular purpose and makes no express

warranties except as may be stated in its written agreement with and for its customer.

In no event is Honeywell liable to anyone for any indirect, special or consequential damages. The

information and specifications in this document are subject to change without notice.

Other brand or product names are trademarks of their respective owners.

Honeywell International

Process Solutions

1860 West Rose Garden Lane

Phoenix, AZ, 85027, USA

+1 800-822-7673

www.honeywell.com/ps

Page 3: DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit Repository (LR) is a software component in BFlex OM Pro suites as well as DOS applications

DynAMo Operations Suite (DOS) Software Change Notice 3

Symbol Definitions The following table lists those symbols used in this document to denote certain conditions.

Symbol Definition

ATTENTION: Identifies information that requires special consideration.

TIP: Identifies advice or hints for the user, often in terms of performing a task.

Page 4: DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit Repository (LR) is a software component in BFlex OM Pro suites as well as DOS applications

DynAMo Operations Suite (DOS) Software Change Notice 4

Contents

1 Introduction ........................................................................................................................ 5 1.1 Overview5 1.2 Contact Us ..................................................................................................................................... 5

2 Release Overview ............................................................................................................... 6 2.1 New features .................................................................................................................................. 6 2.2 Special Considerations .................................................................................................................. 8 2.3 Requirements/Issues Addressed in this Release ........................................................................ 10 2.4 Documentation Updates/Additional Information ........................................................................... 11

3 Installation ........................................................................................................................ 12 3.1 Prerequisites ................................................................................................................................ 12 3.2 Preinstall tasks ............................................................................................................................. 12 3.3 Order of Installation ...................................................................................................................... 12 3.4 Installing DOS R211.2 patch........................................................................................................ 12 3.5 Post installation tasks .................................................................................................................. 15

4 Localization ...................................................................................................................... 17 4.1 Post localization task .................................................................................................................... 18

5 Usage ................................................................................................................................ 19 5.1 Sorting Asset order ...................................................................................................................... 19 5.2 Setting asset preferences in Roll-up comments snippet .............................................................. 20 5.3 Adding tables in the Comments Editor ........................................................................................ 23 5.4 Working on Instructions in Grid view............................................................................................ 24 5.5 Monitoring trend display changes ................................................................................................ 25 5.6 Adding inside and outside actions in Limit Repository (LR) ......................................................... 26

Page 5: DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit Repository (LR) is a software component in BFlex OM Pro suites as well as DOS applications

DynAMo Operations Suite (DOS) Software Change Notice 5

1 Introduction

1.1 Overview Honeywell’s DynAMo® Operations Suite (DOS) R211.2 includes the DynAMo Operations Logbook (DOL), DynAMo Operations Tasks (DOT), DynAMo Operations Monitoring (DOM) and DynAMo Operations Instructions (DOI) applications.

DynAMo® Operations Logbook helps personnel across the plant who work together to achieve greater operational reliability. The electronic log consolidates information from different sources to provide a consistent and up-to-date view of key process data, problems, operating plans, and shift log. A well-designed shift summary report is the basis for an effective and secure shift handover that is critical to efficiently and safely operate your facilities.

DynAMo Operations Monitoring (DOM) application enables your operations team to keep the process in the safe and profitable best operating zone. DOM proactively monitors plant processes, ensuring that the operations safely stay within optimal production envelopes, and ensuring the integrity of the operating windows. With tools designed to manage and control critical limits and process deviations, DOM boosts the reliability, safety, and efficiency of plant operations.

DynAMo Operations Tasks (DOT) is a new capability which enables users (Operations planners, Supervisors, Operators, and so on.) in managing the routine and ad hoc tasks that operation’s team members are required to execute each shift. DOT also introduces a Meeting functionality that allows users to capture the notes and actions of operations meetings to be tracked with the new Task capability. An Instruction applies to some part of a process plant, which may be the entire plant, or a process unit, or a single piece of equipment. An instruction has a start and end date, some notes providing information, and target details (optional). Each target has a minimum, maximum, and/or focus values for the process data. For example, a target detail can define a minimum and maximum range for a temperature, or a desired (focus) production rate, or minimum product quality. The numerical targets such as low, high and focus values are called Limits. These limits can be downloaded, and can be used for monitoring using the operations Monitoring application

Limit Repository (LR) is a software component in BFlex OM Pro suites as well as DOS applications used to integrate the DOS applications. The Limit Repository provides a comprehensive view of limits from many applications, making it possible to see the limits together and in context, regardless of source.

1.2 Contact Us Please send any comments or questions to the Help Desk at [email protected]. Ensure that you type the respective application name (for example, DOS) in the subject line of your e- mail.

Page 6: DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit Repository (LR) is a software component in BFlex OM Pro suites as well as DOS applications

DynAMo Operations Suite (DOS) Software Change Notice 6

1.2.1 Technical Assistance For information on contacting Honeywell Support, visit https://www.honeywellprocess.com/en- US/contact-us/customer-support-contacts/Pages/default.aspx.

1.2.2 Reporting a security vulnerability For submission, a security vulnerability is defined as a software defect or weakness that can be exploited to reduce the operational or security capabilities of the software. Honeywell investigates all reports of security vulnerabilities affecting Honeywell products and services. To report a potential security vulnerability against any Honeywell product, please follow the instructions at: https://honeywell.com/pages/vulnerabilityreporting.aspx. Submit the requested information to Honeywell using one of the following methods:

• Send an email to [email protected] OR

• Contact your local Honeywell Technical Assistance Center (TAC).

2 Release Overview

2.1 New features

Following are the features added in the current release.

Common enhancements in DOS

Enhancement Reference Order of the assets can be defined using the excel add-in or asset configuration in UI.

Sorting Asset order.

Enhancements in DOL

Enhancement Reference

Filtering preferences for the assets can be defined in the roll- up comments per asset.

Setting asset preferences in Roll-up comments.

Comment snippet and asset comments are enabled to add tables for grid data.

Adding tables in the Comments Editor.

Page 7: DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit Repository (LR) is a software component in BFlex OM Pro suites as well as DOS applications

DynAMo Operations Suite (DOS) Software Change Notice 7

Enhancements in DOI

Enhancement Reference

Instructions can be viewed in the Grid view. In the Grid view, you can:

• filter the instructions based on the type • enter/update the plan note • update the limit values • update the start and end times for the draft

instructions • sort assets by column • perform bulk operations on the instructions with same

status

Working on Instructions in Grid view.

Enhancements in DOM

Enhancement Reference

Monitoring trend display is enhanced to display the graph based on the steps performed at each stage rather than displaying the linear view for both monitored and raw values.

Monitoring trend display changes.

Enhancements in LR

Enhancement Reference

While defining variables, the field ‘Actions’ is renamed as ‘Inside Actions’ and a new field ‘Outside Actions’ is added. Outside actions are posted from ACM and are used by the field operators. For more details, refer to the latest ACM guides.

Adding inside and outside actions in Limit Repository.

Page 8: DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit Repository (LR) is a software component in BFlex OM Pro suites as well as DOS applications

DynAMo Operations Suite (DOS) Software Change Notice 8

2.2 Special Considerations

Following are the special considerations identified in the current release.

Description Workaround PAR ID(s)

After viewing the trend for a target from the summary page, if you try to view the trend for a different target from the deviation page, the trend is displayed for the target selected in the summary page but not for the target selected in the deviation page.

NA RDOS-1347

When multiple targets are selected to view the trend for the raw values, the message “insufficient information to plot trends/limit” is displayed.

NA RDOS-1346

While viewing a trend for a target with a specific time range, if you select multiple targets, the time range is automatically changed to the current shift.

NA RDOS-1348

By default, the PV value is displayed for all the trends. While viewing the trend for a target, if you unselect the Limit trend, the trend graph for the PV value might disappear for the selected target.

NA RDOS-1349

If you copy a table from the excel into the Logbook Comments or Instructions Plan Note pages, the borders for the copied table are not displayed.

After copying table from excel or word, if you press Backspace button, the cursor selection still does not come out of the table.

While copying a table from the excel, make sure you copy one cell more on all sides of the table.

RDOS-1321

If you minimize the Target configuration pages below the supported resolution, the controls in the UI might overlap.

Do not minimize the target configuration pages beyond the minimum supported resolution.

The user interface screens of DynAMo Operations Suite are best viewed with a screen resolution of 1200px x 800px or higher.

RDOS-1362

Page 9: DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit Repository (LR) is a software component in BFlex OM Pro suites as well as DOS applications

DynAMo Operations Suite (DOS) Software Change Notice 9

Description Workaround PAR ID(s)

DOSR211 Logbook & Monitoring Reports are not getting opened from Web Server.

For details, refer to the post install task Run the SSRS script.

1-8ROZMZI

Limit repository synchronization does not work.

Parts folder for limit repository is not created automatically.

Note: In case of multi-server scenario, you must perform this step in the application server.

You must create a folder with name ‘Parts’ in the following path: <Install Path> Honeywell\MES\ LimitRepository \Service\LRSyncConf\1.0>.

RDOS-1225

If CAM Scope Permission is enabled, the asset Hierarchy may not be displayed in DOS applications.

CAM Scope permissions are not applicable for the DOS applications.

You must disable Intuition>Common Asset Model> Scope Permission for all the roles.

NA (This is a configuration setting to view the asset hierarchy.)

The shift summary report displays overlapping data in the PDF.

If you are configuring multiple snippets per row, ensure that the cumulative widths of all the snippets must be less than the width of an A4 size sheet.

Tip: You can use the Preview option to view and adjust the widths of the snippets.

RDOS-1406

The trend graphs are not displayed.

You must have security permission ‘view monitoring configuration operation’ to view the trend graphs.

RDOS-1409

In the log book shift reports, the remarks option is disabled for the table snippets that do not have a unique key.

While selecting columns to associate them with comments, you must ensure that the selected columns form a unique key. For more details, refer to the DOL configuration guide.

Page 10: DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit Repository (LR) is a software component in BFlex OM Pro suites as well as DOS applications

DynAMo Operations Suite (DOS) Software Change Notice 10

Description Workaround PAR ID(s)

In Monitoring application, after adding the remarks to a deviation, the respective alert generated for that deviation must be removed from Alert client automatically. But, the alert is not getting removed from the alert client.

In the Application server, perform the following:

1. Browse to <Install

Path>Honeywell\MES\Monitoring \WWWImpl

2. Open the web.config file. 3. Search for the key

"AlertServerAddress" and update its value with the fully qualified web server name and the port number as ‘909’ in the following format: <add key="AlertServerAddress" value= "FullyQualifiedWebserverName:909" /> For example <add key="AlertServerAddress" value="IE3BVWDOSDIT2.global. ds.honeywell.com:909" />

4. Save the file.

RDOS-1404

While rejecting multiple instructions in the summary page (tile view or grid view), the instructions are rejected but an error message is displayed.

NA RDOS-1285

2.3 Requirements/Issues Addressed in this Release At the time of this release, the following issues are fixed.

Description Application PAR ID(s)

In the DOM deviations and summary pages, past deviations data is displayed when the time range is set for future. In fact, future deviation records are not available in the system.

DOM RDOS–1191 / RQUP 2017-004063

Error message ‘Key does not exist’ is displayed while trying to post a comment for a multi-tag snippet with the serial number column.

DOL RDOS-1163

Only the author of a comment must be able to edit it. But, edit button for the comments is enabled for all users.

DOL RDOS-1192

LR Reason, consequences, and (both inside and outside) actions text fields are now enabled to enter more than 2000 characters.

LR 1-83EZB9L

If a table is copied to the comments snippet or plan note, the cursor selection does not come out from the table.

DOL 1-8H3CNOL

Page 11: DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit Repository (LR) is a software component in BFlex OM Pro suites as well as DOS applications

DynAMo Operations Suite (DOS) Software Change Notice 11

Description Application PAR ID(s)

While navigating to LR from DOM application, LR trend page becomes inoperable.

DOM and LR 1-8MIMPZL

DOM application is unable to generate trends when raw data is selected for targets.

DOM 1-8E1VD1N

Some of the approved shift log pages are not converted to PDF.

DOL 1-8N4IMLP

DOM Trends are not generated if IE language settings are set to Korean.

DOM 1-8IEP227

Unable to generate LR trends for variables. LR 1-8N4IMOX

Responses from the server might be delayed while configuring comprehensive security model.

DOS 1-87L6SE4

Localized Korean Logbook application is unable to generate reports properly in Korean language.

DOL 1-8NAA61N

The DOS search functionality might retrieve inaccurate details if the application is idle for longer duration after performing search using alphanumeric values.

DOS RDOS-1350

If you navigate to LR console from search page, loading of the LR console page takes longer time.

LR RDOS-1361

In the target configuration page, the search words disappear after pressing Enter.

DOM RDOS-1359

In the Shift Association page, delete icon appears. Shift Association page does not require the delete option.

DOL RDOS-1363

While viewing the trend for a target of an equipment, if you navigate to another equipment the message “Invalid Target” is displayed.

DOS RDOS-1323

User could not update or delete the previously entered text in the comments field.

DOL RDOS-1456

2.4 Documentation Updates/Additional Information The documentation updates for the current release have been updated in this document. The BFlex-DOS Migration document is also updated and delivered in this release.

Page 12: DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit Repository (LR) is a software component in BFlex OM Pro suites as well as DOS applications

DynAMo Operations Suite (DOS) Software Change Notice 12

3 Installation This section describes how to install the current patch.

3.1 Prerequisites You must have DOS R211.1 installed in the machine.

3.2 Preinstall tasks

3.2.1 Stop the Honeywell services NOTE: In case of multi-server scenario, this step must be performed in the application server. If you are upgrading from previous releases, then you have to stop the following services. To stop the services, perform the following steps.

1. Choose Start>Run and type services.msc and click OK. The Services window appears.

2. Right-click the following services:

• Honeywell Intuition Operations Monitoring HDA Target Service • Honeywell Intuition Operations Monitoring DA Target Service • Honeywell Intuition Limit Repository Core Sync Scheduler • Honeywell Intuition Event Processing Service

3. Click Stop.

3.2.2 Stop the font services In case of three server-scenario, perform the following steps in the web server:

1. Choose Start>Run and type ‘services.msc’ and click OK. The Services window appears.

2. Right-click the service Windows Font Cache Service and click Disable.

3.3 Order of Installation The following applications/components must be installed in the same order as mentioned.

1. Install DOS R211.2 patch.

• Common Asset Model (CAM) must be installed in all servers.

• Select only the applications that are previously installed.

2. Install the core components.

3.4 Installing DOS R211.2 patch In case of multi-server scenario, you must perform this step in all the servers. To install the current release, perform the following steps:

1. Copy the DOS R211.2 release media to the current server. Henceforth, the location is called Copied Path. Note: It is not recommended to copy the release media on the desktop.

Page 13: DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit Repository (LR) is a software component in BFlex OM Pro suites as well as DOS applications

DynAMo Operations Suite (DOS) Software Change Notice 13

2. In the copied path, browse to the folder DOS R211.2. 3. Right-click the file ‘setup.exe’ and then select ‘Run as administrator’.

The Welcome page appears. 4. Click Next.

The Patch Details page is displayed. Only the components that are installed as part of R211.1 are enabled to get upgraded to R211.2. Select the check boxes of the components that you want to upgrade to R211.2. Note: You must install Honeywell Common Asset Model in all the servers.

5. Click Next. The Summary page is displayed listing all the applications selected for the installation.

6. Click Finish. After installing DOS R211.2, a message is displayed informing the installation is successful.

3.4.1 Installing core components In case of multi-server scenario, you must perform this step in all the servers. To install the core components, perform the following steps:

1. Copy the DOS R211.2 release media to the current server. Henceforth, the location is called Copied Path. Note: It is not recommended to copy the release media on the desktop.

2. In the copied path, browse to the folder <copied path>\DOSR211.2\Patches\Core System R280.5 Point Release.

3. Right-click the file ‘MES_Update_Manager.exe’ and then select ‘Run as administrator’. The Welcome Intuition Core System R280.5 page appears.

4. Click Install. After installing the core component, a message is displayed informing the installation is successful.

3.4.2 Installing client components In the current release, the excel add-in client components are updated. You must install these updates in the client machine. You can skip this section if you are using only DOM popup alert client. No changes are made for the DOM popup alert client. Prerequisite

• DOS R211.1 client is installed in the machine To install the client components, perform the following steps:

1. Copy the DOS R211.2 release media to the current server. Henceforth, the location is called Copied Path. Note: It is not recommended to copy the release media on the desktop

2. In the copied path, browse to the folder DOS R211.2. 3. Right-click the file ‘setup.exe’ and then select ‘Run as administrator’.

Page 14: DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit Repository (LR) is a software component in BFlex OM Pro suites as well as DOS applications

DynAMo Operations Suite (DOS) Software Change Notice 14

The Welcome page appears. 4. Click Next.

The Patch Details page is displayed. Only the components that are installed as part of R211.1 are enabled to be upgraded to R211.2. Select the check boxes of the DOS client components that you want to upgrade to R211.2.

5. Click Next. The Summary page is displayed listing all the applications selected for the installation.

Page 15: DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit Repository (LR) is a software component in BFlex OM Pro suites as well as DOS applications

DynAMo Operations Suite (DOS) Software Change Notice 15

6. Click Finish.

After installing DOS R211.2 client components, a message is displayed informing the installation is successful.

3.5 Post installation tasks This section lists the tasks that must be performed after installing DOS R211.2.

3.5.1 Enable windows font cache service In case of three server-scenario, perform the following steps in the web server:

1. Choose Start>Run and type ‘services.msc’ and click OK. The Services window appears.

2. Right-click a service and click Enable. • Windows Font Cache Service • Honeywell Intuition Operations Monitoring HDA Target Service • Honeywell Intuition Operations Monitoring DA Target Service • Honeywell Intuition Limit Repository Core Sync Scheduler • Honeywell Intuition Event Processing Service

3.5.2 Copy the files In case of three server-scenario, perform the following steps in the web server:

1. Browse to the folder <R211.2 Media>PostInstall, copy the file AssetHierarchy.cshtml. 2. Replace the file in the following location <Install

Path>:Honeywell\MES\Task\UI\WebUI\Views\AssetHierarchy\. In case of three server-scenario, perform the following steps in the application server:

1. Browse to the folder <R211.2 Media>PostInstall, copy the file Honeywell.MES.Service.Task.TaskRuntime.BusLogic.dll.

2. Replace the file in the following location <Install Path>: \Honeywell\MES\Task\Service\TaskRuntime\1.0\bin\.

Page 16: DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit Repository (LR) is a software component in BFlex OM Pro suites as well as DOS applications

DynAMo Operations Suite (DOS) Software Change Notice 16

3.5.3 Run the security configuration xml This task is required only for high availability scenarios. You must perform this task in one of the application server.

1. Browse to the folder <R211.2 Media>\PostInstall>, open the file

‘CAMSecurityConfiguration’. 2. You must update the database ‘[Honeywell.Intuition.Base].[Security].[VersionInfo]’ to

132.0. Note: In case of custom database, you must update the value for the custom database.

3. Run the CAMSecurityConfiguration.xml file using MESSecurityConfigLoader.exe in Command prompt.

Command to run the files cd "<{ MESSecurityConfigLoader.exe folder path}>" MESSecurityConfigLoader.exe /configFile:{CAMSecurityConfiguration.xml path}

Sample command cd "<C:\Users\H258826\Downloads\Honeywell_Intuition_Core_System_R280.1\CoreSyste m\MES\DataDrivenExe>" MESSecurityConfigLoader.exe /configFile:C:\Temp\CAMSecurityConfiguration.xml.

3.5.4 Run the SSRS script This section is applicable only for the users with SQL Server 2016. Skip this section if you are using earlier versions of SQL Server. In case of three-server scenario, you must perform this task in the database server.

1. Browse to the folder <R211.2 Media>\PostInstall>, open the file ‘SSRS Report Script’. 2. In the script file, update the values for the following parameters:

• ReportServerName: Fully qualified name of the server in which SSRS reports are configured.

• ServerInstanceName: The SQL server connection instance name. • Protocol: The protocol configuration of the site, HTTP or HTTPS. • PortNo: Port number of the SSRS report server.

3. Run the script in the DOS database server. 4. Perform the IISRESET in both Web and Application servers.

3.5.5 Deploy the configuration file In case of three-server scenario, you must perform this step in the Web server. Perform the following steps:

1. Browse to the folder <R211.2 Media>\PostInstall>, copy the file ‘LogBook.CommonFunctions.js’.

Page 17: DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit Repository (LR) is a software component in BFlex OM Pro suites as well as DOS applications

DynAMo Operations Suite (DOS) Software Change Notice 17

2. Replace the file in the following location: <Install Path>\Honeywell\MES\Logbook\UI\WebUI\Scripts.

3.5.6 Clear the cache After upgrading to R211.2, the browser cache retains the pre-upgrade details such as UI icons, java scripts and so on. You must refresh the cache in the client machines.

4 Localization You must use the latest DLLs delivered with the current release to localize the DOS applications.

To use the latest DLLs, perform the following steps:

For Monitoring application

Copy the DLLs from the following R211.2 media location • \DOSR211.2\Patches\Monitoring R211.2> Point Release\Localization

Replace them in DOM R211 media in the following location

• DOMR211\Localization\Operation Monitoring\Source

For DOI application Copy the DLLs from the following R211.2 media location

• DOSR211.2\Patches\Instruction R211.2> Point Release\Localization

Replace them in DOI R211 media in the following location • DOIR211\Localization\Operation Instructions\Source

For Logbook application

Copy the DLLs from the following R211.2 media location • DOSR211.2\Patches\Logbook R211.2 Point Release\Localization

Replace them in DOL R211 media in the following location

• DOLR211\Localization\Operation Logbook\Source

For Opmgmt service Copy the DLLs from the following DOS R211.2 media location

• DOSR211.2\Patches\Instruction R211.2 Point Release\Localization

Replace them in both DOM and DOL R211 media in the following locations respectively • DOMR211\Localization\OPMgmt\Source\ • DOLR211\Localization\OPMgmt\Source\

Page 18: DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit Repository (LR) is a software component in BFlex OM Pro suites as well as DOS applications

DynAMo Operations Suite (DOS) Software Change Notice 18

4.1 Post localization task This step must be performed only if you have localized DOS to another language. You can skip this section if you are using DOS standard version. For example, if you have translated DOS to Korean language, you must perform this step.

1. Open Control Panel.

2. Click Clock, Language, and Region.

3. Click Region and Language. 4. Click the Formats tab. 5. From the Format drop-down list, select the required language such as Korean. 6. Click Apply. 7. Click OK to save the changes.

Page 19: DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit Repository (LR) is a software component in BFlex OM Pro suites as well as DOS applications

DynAMo Operations Suite (DOS) Software Change Notice 19

5 Usage This section describes how to use the new features added in the current release.

5.1 Sorting Asset order By default, new assets are sorted based on the alpha-numeric values. The sites, that need to view the assets in the connected flow rather than the alpha-numeric values, can reorder the assets by dragging and dropping the assets or providing the asset sequence in the asset configuration excel. The assets without any value are displayed first followed by the assets with values. After sorting the orders, the shift rotation of the new parent asset is applicable for the moved child assets.

To sort the Asset order, perform the following steps:

1. Open the DOS application. 2. Under Operations group, click Configurations > Asset configuration.

The Asset configuration window appears. In the right pane, under the Hierarchy Tree group, the Asset hierarchies are displayed.

3. Drag-and-drop the assets based on your requirement.

To sort the Asset order using excel add-in, perform the following steps:

1. Open the Asset configuration excel add-in. 2. In the Asset_Hierarchy sheet, provide the sorting order (value) under Sort Order column

for each asset. By default, the assets without values (null) are displayed first followed by the numeric values.

Page 20: DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit Repository (LR) is a software component in BFlex OM Pro suites as well as DOS applications

DynAMo Operations Suite (DOS) Software Change Notice 20

3. Click Publish. 4. Upload the configuration excel add-in sheet. For more details, refer to any of the DOS

configuration guides.

5.2 Setting asset preferences in Roll-up comments snippet Roll-up comments snippet is enabled to set the asset preferences. Only the preferred asset details are displayed in the roll-up comments snippet rather than displaying all the assets. After setting the asset preferences, the preference details are saved and retrieved for all the users of that roll- up comment snippet.

Prerequisites You must have the following permissions assigned to your role to set the asset preferences. Note: By default, these permissions are enabled when you install DOS R211.2.

• Opmgmt > Asset Preference Personalization.

Page 21: DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit Repository (LR) is a software component in BFlex OM Pro suites as well as DOS applications

DynAMo Operations Suite (DOS) Software Change Notice 21

• Logbook > View ShiftSummary.

Configuring Asset Preference

To configure asset preference for a roll-up comment, perform the following steps: 1. Select an asset in the Asset Tree.

2. In Asset column of rollup snippet, click the filter icon . The Asset filter popup displays the child assets of the selected asset.

Page 22: DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit Repository (LR) is a software component in BFlex OM Pro suites as well as DOS applications

DynAMo Operations Suite (DOS) Software Change Notice 22

3. Select the check boxes of the assets to mark them as preferred assets. 4. Click Save filter to save the preferences.

The asset preferences are saved.

5. Click the Clear Filter to clear the asset preferences.

Disabling Asset Preferences

Asset Preference can be disabled by removing the “Asset Preference Personalization” security Operation permission for the corresponding role.

Page 23: DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit Repository (LR) is a software component in BFlex OM Pro suites as well as DOS applications

DynAMo Operations Suite (DOS) Software Change Notice 23

5.3 Adding tables in the Comments Editor The comments editor is now enhanced to add the tables for both asset comments and comment snippet.

To add a table, perform the following steps:

1. In the Logbook application, click Console and navigate to the Shift Summary or Comments tab. Invoke the asset comments popup or launch a shift summary with a comment snippet in it. For more details, refer to the DOL user’s guide.

2. Click on the Table Wizard icon available in the rich text editor or copy-and-paste the table data to the editor.

Page 24: DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit Repository (LR) is a software component in BFlex OM Pro suites as well as DOS applications

DynAMo Operations Suite (DOS) Software Change Notice 24

• To quickly insert a table, click on the Table Wizard icon and move the cursor over the grid until you highlight the number of columns and rows you want to create.

OR

• Click the Table Wizard option to enter the number of columns and rows

you want to create. Note : You can also add width, height, borders, border color, border style, and so on to the table using the Table Wizard option.

5.4 Working on Instructions in Grid view In the Instructions console, the default display of the instructions is changed to grid view from the tile view. In the grid view, you can modify the details of the instructions if the instruction is in draft state and is not being used by other users. Note: When you expand and edit an Instruction, you must save the Instruction details first to perform any other actions such as submit, schedule and so on. Alternatively, you can collapse the Instruction and then select the Instruction row to perform these actions. For information on Instructions, refer DynAMo Operation Instructions user guide. To update the Instructions in the grid view, perform the following steps:

1. Open the Instructions application. The instructions are displayed in a grid view. Note: You can filter the instructions based on their type by clicking on the Type column.

• icon indicates the limit instruction.

• icon indicates the text instruction.

Note: The icons displayed in the Status column indicate the status of the instruction and the action needs to be performed. For example, overdue instruction is indicated by the

icon . For details on the icons, refer to the DOM user’s guide.

2. Click on an instruction to select it. When an instruction is selected, all instructions with status other than the selected instruction status are disabled. The action icons list is updated based on the status of the selected instruction.

Page 25: DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit Repository (LR) is a software component in BFlex OM Pro suites as well as DOS applications

DynAMo Operations Suite (DOS) Software Change Notice 25

3. You can select multiple instructions with same status to perform actions on all the selected instructions at the same time.

4. The Instructions can be sorted in alphabetical order. You can sort in ascending order (A to Z) or in descending order (Z to A). If you click the name of any column: • Once – the table is sorted in ascending order. • Twice – the table is sorted in descending order. • Thrice – the table is set to the default view.

5. Click the expand icon to update the details of an instruction. Note: When an instruction is expanded by a user, the instruction is locked for that user until the user closes the instruction. The locked instructions cannot be edited by other users. Update the following details for the selected instruction: • Text instructions: Start time, End time, and Plan note. • Limit instructions: Start time, End time, Plan note, and the Limit values.

6. Click Save to update the changes.

7. In the Console page, click on the icon to view the instructions in the tile view.

5.5 Monitoring trend display changes Monitoring trend graph is enhanced to display the graph based on the steps performed at each stage rather than displaying the linear view. The trend graph enhancements are applicable for both monitored and raw value trends.

1. In the DOS home page, click Monitoring. 2. Click the Summary tab. 3. In the Summary tab, select a target for which you want to view the trend. 4. Click Trend tab.

The trend is displayed based on the changes made at each step rather than the linear graph.

Page 26: DynAMo Operations Suite (DOS) - Honeywell · 2018-01-19 · 3.5 Post installation tasks ... Limit Repository (LR) is a software component in BFlex OM Pro suites as well as DOS applications

DynAMo Operations Suite (DOS) Software Change Notice 26

5.6 Adding inside and outside actions in Limit Repository (LR) Console operators and field operators refer the inside and outside actions respectively for bringing the operating deviations within safe operating zone. The outside actions are mainly used by field operators, this value is retrieved from LR configuration, excel add-in bulk configuration, or external applications (ACM).

Special consideration: ACM LR synchronization service retrieves all the details from the ACM server except the outside actions. For information on Limit Repository and Configuring Variables in Limit Repository, refer Limit Repository user and configuration guides.