DX AIR CURTAIN SensAir · 2017-10-09 · Daikin DX: Direct expansion SRQ S-100 not available...
Transcript of DX AIR CURTAIN SensAir · 2017-10-09 · Daikin DX: Direct expansion SRQ S-100 not available...
SensAir
DXAIRCURTAIN
BiddleandDaikin
CompleteclimatesystemSince2006BiddleandDaikinhavejoinedforcestoprovideacompleteclimatesystemforshopsandpublicbuildings.By
combiningBiddleaircurtainswiththehighleefficientDaikinheatpumpsystems,alotofenergyissavedandcomfortinthe
buildingisoptimum.
MaximumcomfortBothvisitorsand
personnelcanenjoy
maximumcomfortduring
thewholeyear,underall
weatherconditions.Thisis
theresultoftheefficient
climateseparationcreated
byBiddleaircurtains,
whileheatpumpsystems
heat,coolorventilateto
provideacomfortable
indoorclimate.
IntegratedairconditioningsolutionsTheadvantageofcombiningaircurtainswithheatpumpsandheatrecoveryisthatclimateseparation,heating,coolingand
ventilationarecombinedinonesystem.Considerablesavingsonenergycostscanbemadeascomparedwithtraditionalsystems;
thismeansthatthepaybacktimeisveryshort,generallyabout1.5years.Thestableindoorclimateduetoefficientclimate
separationreducesheatlossthroughthedoorwayandalsoincreasestheefficiencyoftheDaikinsystems.ADaikinheatpumpis
veryefficientandsavesupto40%ofenergycostsascomparedwithahigh-efficiencycentralheatingboiler.ABiddleaircurtainin
combinationwithDaikin’sheatpumpsystemsistheultimateenergy-savingsolutionforcooling,heating,ventilationandclimate
separationandmeansthatotherenergygenerators,suchasacentralheatingsystem,arenotrequired.
DaikinclimatesystemsBiddleaircurtainscanbeinstalledplug&playtovariousDaikinclimatesystems.
Heatpump/heatrecovery:forheatingand/orcoolingabuilding.Theheatreleasedfrom
coolingsystems(residualheat)isrecycledfortheBiddleaircurtain.
Conveni-pack:auniquetotalsolutionforrefrigeratedstorageandairconditioning,where
energyconsumptionisreducedtoaminimumasupto100%oftheheatisrecoveredfrom
coolingequipmentandusedtoheatthearea.Thisiswithoutadditionalcosts.
SensAirDXaircurtains
AnewwaveinclimateseparationSensAiraircurtainsaretheidealsolutionforretailersandotherend-userstocombattheissueofclimateseparationacrosstheir
outletorofficebuildingdoorway.Theimportanceofaccessibilitytoattractcustomersintheretailsectoriswell-known,butwiththis
freeformofaccessthrough‘opendoor’trading,colddraughtsandhigh-energybillsareoftentheconsequence.
HighcomfortandenergyefficientTheSensAirtechnologyhasbeenimprovedtodeliver
greatercomfortforall,whetheritisinasupermarket,high
streetstoreorofficebuilding.TheSensAiraircurtain,does
notactasabarrierintheplaceofadoor,itsprimeroleisto
reducetheamountofwarmairleavingthebuildingand
conditiontheincomingairtoacomfortabletemperature.
BSRIAandBiddleresearchproduceddocumentedevidence
provingthataircurtainsoperatebestwithspecificvelocities
andairvolumes.TheSensAiraircurtainsatisfiestheseneeds
bydeliveringtherightairflowandtemperatureattheright
timeautomatically,reducingenergyloss.Furthermoreitisthe
onlycommerciallyavailableaircurtainofitskindthatnow
offersauniqueairdampersystemtoimproveefficiency,by
controllingtheoutletvelocity.
Intelligentauto-activecontrolandmonitoringTheauto-activecontrolisthenextgenerationofcontrols.
Knowingthatmanualcontrolofaircurtainsoftenleadstothe
incorrectsettingtheinclusionoftheautomaticCHIPS
(CorrectiveHeating&ImpulsePredictionSystem)technology
ensuresthemostappropriatesettingatanymomentintime.
Thei-senseinthedischargegrillemeasurestheindoorand
outdoortemperaturesactiveinthedooropeningresultingin
accuratedata.Thisauto-activecontrolhasbeen
demonstratedtoproduceenergysavingsavingsofupto
75%whencomparedwithamanuallycontrolledaircurtain.
Biddlehasanextensiverangeofcontroloptions:theb-touch
controlpanel,remotemonitoringofcomfortandenergy
performanceandconnectingtoaBMSiseasythroughthe
standardintegratedModbusconnection.
BenefitsEnergyefficientandhighcomfort
-improvedaccuracyoftemperaturedatacollection
-correctsettingsareadjustedactivelyandautomatically
-comfortableinsideclimateandinvitingappearance
-lowsoundlevel
Intelligentcontrolandmonitoring
-self-regulating:auto-activecontrol
-remotemonitoring:b-connect
-Modbus:integratedasstandard
Installation&maintenance-friendly
-easytoassembleandsetup(b-touch)
-ready-to-use,integratedcontrol
Completecustomizedsolution
-customerspecificstylingpossible
-suitableforvariousheatsources
SensAirandDaikin
Energy-efficientclimateconceptBiddleandDaikinsupplyacompleteplug&playclimateconcept.Withinthisenergy-efficientclimateconcepttwodifferent
versionsareavailable:theSRVandSRQmodels.
CompleteSRVaircurtain–climatesystemTheclimatesystemconsistingoftheSensAiraircurtain,model
SRV(1),DaikinVRVoutdoorunit(2)andindoorunits(3)suppliesheating,cooling,ventilationandclimateseparationin
oneenergy-efficientinstallation.Byheatingandcoolingatthe
sametimetheheatextractedfromthecoolingsystemscanbe
extractedfortheaircurtain,thusresultinginconsiderable
reductioninenergycosts.Thisintegratedclimatesystemis
energyefficient,hasaquickpaybacktimeandprovidesa
comfortableindoorclimate.
StandaloneSRQaircurtain–heatpumpTheSensAiraircurtain,modelSRQ(1),isavailablein
combinationwithaDaikinERQheatpump(2).Theheat
pumpprovidestheheatingenergyrequiredforclimate
separationinthedoorway.Theheatingandcoolinginthe
buildingarecontrolledseparately(3).Considerableenergy
savingsareobtainedbyconnectingtheSensAirtoaheat
pump:upto40%ascomparedwithahigh-efficiencyboiler
andeven73%ascomparedwithanelectricaircurtain.This
climatesolutionissustainable,energysavingandcreatesa
pleasantindoorclimate.
TheSensAirisalsoavailableasahybridDXversion
ConstantheatingwithhybridSensAirThehybridSensAirconsistsofaDXandanadditionalelectric
heatingelement.Firstmaximumuseismadeoftheavailable
heatfromtheDX.Ifnecessary,theelectricelementswitches
onautomaticallysothattherequireddischargetemperature
canbeachievedcontinuously.Incoldweathertheelectric
elementswitchesonautomaticallyiftheoutdoorunitisnot
adequatetosupplythecapacityrequired.Theelectric
elementalsosuppliestheheatingrequiredduringthe
defrostingcycle.Inthiswayclimateseparationisalways
guaranteed.
SensAirauto-activecontrol
IntelligentcontrolandmonitoringThereareanextensiverangeofcontroloptions;touchscreencontrol(b-touch),remoteoperationandintegrationwithaBuilding
ManagementSystem(BMS).Itispossibletomonitortheenergyperformanceandcomfortlevelsremotelybymeansoftheb-
connectmonitoringmodule.ConnectingtoaBMSiseasythroughastandardModbusProtocolconnection,whilstitisalso
possibletocommunicateviaBACnet.AllSensAirdevicesarefittedwithBiddle'sinnovativeauto-activecontrol,thenextgeneration
ofcontrols.
Auto-activecontrolGenerally,installinganaircurtainistypicallysettooperateatamid-speedsettingandrarely
adjusted.Thisresultsintheaircurtaincontinuallyoperatingatasingleairvolume,velocityand
temperature.However,asinternalandexternalconditionsconstantlyvarythismeanstheair
curtainwillonlybeoperatingattheoptimumsettingsomeofthetime,andfortherestofthe
timewillbeoneithertoohighortoolowasetting.TheautomaticCHIPS(CorrectiveHeating
&ImpulsePredictionSystem)technologyensuresthemostappropriatesettingatanymoment
intime.Thei-senseinthedischargegrillemeasurestheindoorandoutdoortemperatures
activeinthedooropeningresultinginaccuratedata.ThisprocessensuresthattheSensAiris
alwaysfunctioningcorrectlyandyieldsanideal,energy-efficientindoorclimatewithout
interferenceoftheuser.
b-touchcontrolpanel
ArevolutionarycombinationoftechnologiesSensAir’sauto-activecontrolcombinesnofewerthanfourrenownedBiddletechnologies.The
revolutionarypatentedi-senseinfraredtechnologycollectsalltemperature-relateddatainthe
doorway.CHIPStechnologytranslatesthisinformationintothecorrectsetting,whilstthe
adaptabledischargewidth(ControlledAirstrengthtechnology)andthepatentedrectifier
createtheperfectclimateseparation.
YouwillfindmoreinformationregardingSensAir’scommercialadvantagesinaseparatebrochure.
BenefitsCombinationSensAir-Daikin-Sustainableclimatesolution
-Integratedclimatesystempossible
-Extensivecontroloptions
-Extremelylowenergyconsumption
-Lowinvestmentcosts(nocentralheatingneeded)
-Optimalcomfort
-LowCO -emission2
SensAirselection
AircurtainselectionSelectingtherightaircurtainiscrucialinordertoensuretheSensAirworksoptimally.Anaircurtainperformsproperlywhen
itcompletelyshieldsthedoorwayandisstrongenoughtoheatthecoldairstreaminginfromoutsidetoacomfortabletemperature.
AircurtainproductselectorTheselectorenablesasimpleselectionofthemost
appropriateproductforyourentranceanddependson:
Doorheight:mountingheight,measuredfromfloorto
bottomofunit.
Doorwidth:recommendedunitoverhang-minimumof
100mmeachside.
Naturalventilation:volumeandtemperatureofthe
outsideairenteringthroughtheopendoor.
Thefollowingguidelinesgenerallyapply:
S:smallmediumhighstreet:retailoutlets,smalloffices,
commercialreception(upto200m )
M:mediumretailoutlets,foodstores,largercommercial
entrances(200-2,500m )
L:largeretailoutlets,superstores,leisurecomplexes
(2,000-6,000m )
XL:largeretailoutlets,hypermarkets,departmentstores,
shoppingcentreswithhighperformancerequirements
(>5,000m )
2
2
2
2
DesignconsiderationsBiddleispartofyourteamandworkscloselywithconsultantsandarchitectsfromtheearliestdesignstagestoensuretheoptimum
aircurtainsolutionisachievedforbothnewbuildandrefurbishmentprojects.Criticaldesignconsiderationsinclude:
Storelocation,layoutandage
Buildingleakagecharacteristics
Positive/negativepressurisationofthestore
Standardofmechanicalairsupplies
Entrancedoorway,widthandheight
SimulationtoolBiddlehasdevelopedasimulationtooltohelpyouselectthe
rightaircurtain:VACP(VisualAirCurtainPerformance).Biddlehasspecificadviceforalldoorway
scenarios.Formoreinformation,pleasecontacttheBiddle
salesoffice.
Multipledoorsondifferentelevations
Employeeawarenessoftheproblemscausedbyleaving
bulkstoredoorsopeninfoodstores
Lobbied/nodoorenvironment
Environmentalfactors-winddata,directionorspeed
SensAirpossibilities
Asuitablesolutionforeverysituation
TheSensAirhasendlesspossibilities.TheSensAircreates
optimumclimateseparationinalldoorwaysandisalso
suitableforDaikinsystems.Thereisasolutionavailablefor
manymonitoringandcontroloptions.
Exampletypecode:SRVS-100-DK-80-F
SRV = SensAirwithDaikinVRVSRQ = SensAirwithDaikinERQCapacityS = Small(200-240cm)M = Medium(220-280cm)L = Large(250-330cm)XL = ExtraLarge(300-400cm)Length(cm)100-150-200-250DX = RefrigerantR410aDXE = DK+ElectricalheatingCapacityindex80-100-125-140-250ModelF = FreehangingmodelR = RecessedmodelC = Cassettemodel
Forthewater,electrical,hybridandambientversionsaseparatebrochureisavailable.
ForeverydoorwidthDoorswiderthan250cmarecoveredbyplacingmultiple
unitsnexttoeachother.
ControloptionsAuto-activecontrolwithb-touchcontrolpanel
b-connectmonitoringmodule
Modbuscommunication
DaikinDX:Directexpansion
SRQS-100notavailable
StandardcoloursTrafficwhite(RAL9016)withaccentendpanelsinsilver
grey(RAL9006)
Silvergrey(RAL9006)
OtherRALclassiccoloursavailableonrequest
CustomerspecificstylingTheinlaysintheendpanelsaresuppliedingreyandwhite
asstandard.Theremovableinlaysintheendpanelscanalso
bestyledspecificallyifrequired(e.g.colourandlogo).
Endpanelswithstyledinlays
SensAirdeliveryandaccessories
Deliveryandaccessories
i-sense
b-touchcontrolpanel
endpanels-2colours
Technologiesi-senseinfraredtechnologytocollectaccuratetemperaturedatainthedooropening
CHIPStechnologytoadjustthesettingsautomatically
Controlledairstrengthtechnologyforthebestdownwardpenetration
Rectifiertechnologytoreachtheflooratthelowestpossiblespeed
DXversionForacompleteinstallationofmodelSRVorSRQseveraladditionalcomponentstobedelivery
byDaikinarenecessary.
StandarddeliveryModbuscommunication
Airfilters
Ceilingmountingbrackets
DuctconnectionsR-model(ductsnotincluded)
Accessorysetforauto-activecontrolb-touchcontrolpanel
TwoBiddlelowvoltagecables:1x5m,1x25m
Twoendpanels(modelF)
Optionalb-connectmonitoringmodule
Filtersensor
Wallmountingbrackets:standardanddesign
Threadedrodcovers
Doorcontactswitch
Externaloutdoorsensor
InstallationpossibilitiesWallmountingbrackets
M8threadedrods(seealso-threadedrodcovers)
SensAirconnections
ElectricalconnectionsTheSensAirisdeliveredasstandardwiththeb-touchcontrolpanelandi-senseinfraredtechnology.Itisalsopossibletospecify
theoptionalb-connectmonitoringmoduleorcommunicateviaModbus,thelatterofwhichisastandardfeatureonallunits.
1. i-senseinfrared
technology
2. b-touchcontrolpanel
3. b-connectmonitoring
module
4. Modbuscommunication
SensAirDXspecifications
SpecificationsCasingThecasingismadeofzincplatedsheetsteel,andhasaninspectionpanelinthebottom.The
inletgrillesaremadeofanodisedaluminiumwithfixedfins.Theinletmoduleandtheend
panelsaswellasthecasingare,asastandard,suppliedinsilvergrey(RAL9006)ortraffic
white(RAL9016).TheendpanelsofthewhiteSensAirhaveagreyinlay.OtherRALcasing
colourfinishesareavailableforanadditionalcharge.
Motor/FanassemblyTheaircurtainisequippedwithtwoormore(dependingontype)dual-inlet,vibrationfree
suspendedcentrifugalfans.Eachfanisdrivenbyarotormotoronbearings,whicharesealfor
lifeandnomaintenanceisrequired.Thefancasingandtheimpelleraremadeofzinccoated
platesteel.Themotors,asstandard,arefittedwiththermalcontacts.Thesethermalcontacts
breakthecircuitofthemotorwhenthemaximumpermissiblemotortemperatureisexceeded.
HeatingcoilDX:madeupof3/8"coppertubesandaluminiumfins.Thefluidconnectionis9.52mm,and
thegasconnectionis16mm(with100,S/M-150&200,S-250),19mm(withM-250,
L/XL-150)or22mm(withL-200en250).
Hybrid:acombinationofDXwithanelectricalstitchedwireheatingelement.
ConnectionsToconnectDXunitstothemainssupply,theycomewithafixedcable(approx.2mlong)witha
moulded,earthedplug.TheconnectionforDaikinunitsandtheconnectorplatearefittedonthe
topoftheunit.
Themainscableforelectricalheatingmustbeconnectedwithintheunit.Thetopoftheunithas
acableglandforfeedingthroughthefeedercable.A5-corecable(3phases+earth+neutral)
isrequiredforproperconnection.
SensAirDXexplanationoftechnicaldata
ExplanationtechnicaldataBecauseoftheauto-activecontroloftheSensAirDXaircurtaintheoutlettemperaturevariesatallspeeds,dependingonthe
situation.ThemaximumheatingcapacityoftheDXaircurtainsisthesameastheheatingcapacityinthehighestfanspeed.
SelectionDaikinoutdoorunitTodeterminethecorrectDaikinoutdoorunitformodelSRV,youneedtoaddtogetherthecapacityindexesofalltheindoorunits.
SoundThesounddataisbasedonthedirectfield,inasituationwith
anopendoorandasoundabsorbingceiling.Thesounddata
fordifferentsituationscanbedeterminedbyaddingthe
adjacentvaluestothetablevalues.
Closeddoor +1à2dB(A)Acoustical"hard"ceiling +2à3dB(A)
Deviatingdistancesandseveralunitsnexttoeachothercanbecalculatedwiththetablebelow.Datafromthe1munit,measured
atadistanceof3m,isthebasicassumption.Thefactorsapplytoalltypesofaircurtains.
CorrectionfactorsforsoundpressureindB(A)
distance(m) totalunitlength(m)1 1,5 2 2,5 3 3,5
1 +9.5 +11.3 +12.6 +13.5 +14.3 +15.02 +3.5 +5.3 +6.5 +7.5 +8.3 +9.03 0 +1.8 +3.0 +4.0 +4.8 +5.44 -2.5 -0.7 +0.5 +1.5 +2.3 +2.95 -4.4 -2.7 -1.4 -0.5 +0.3 +1.0
NoteTheSRQS-100unitisnotavailable.
SensAirtechnicaldata
DXheatingSRVS-100-DKnominalunitlength m 1 doorheight m 2-2.4electricalsupply V/ph/Hz 230/1/50max.inputcurrent(1phase) A 0,88max.fanpower kW 0,2max.specificfanpower W/l/s 0,63maxheatingcapacity kW 7,8capacityindex 80weightcasingstyleF/R/C kg 52/62/60airinlettemperature °C 20dischargeairtemperature °C 30-45speed 1 2 3 4 5 6airvolume m³/h 440 600 680 880 1010 1130heatingcapacity kW 3,6 4,7 5,2 6,4 7,1 7,8soundpressurelevelat3m dB(A) 27 33 37 42 46 48
SRV/QS-150-DKnominalunitlength m 1,5 doorheight m 2-2.4electricalsupply V/ph/Hz 230/1/50max.inputcurrent(1phase) A 1,32max.fanpower kW 0,3max.specificfanpower W/l/s 0,63maxheatingcapacity kW 9,7capacityindex 80weightcasingstyleF/R/C kg 73/89/84airinlettemperature °C 20dischargeairtemperature °C 30-45speed 1 2 3 4 5 6airvolume m³/h 660 910 1020 1320 1520 1700heatingcapacity kW 4,9 6,2 6,8 8,2 9 9,7soundpressurelevelat3m dB(A) 28 35 39 43 47 50
SensAirtechnicaldata
DXheatingSRV/QS-200-DKnominalunitlength m 2 doorheight m 2-2.4electricalsupply V/ph/Hz 230/1/50max.inputcurrent(1phase) A 1,76max.fanpower kW 0,39max.specificfanpower W/l/s 0,63maxheatingcapacity kW 12,6capacityindex 100weightcasingstyleF/R/C kg 88/109/103airinlettemperature °C 20dischargeairtemperature °C 30-45speed 1 2 3 4 5 6airvolume m³/h 880 1210 1360 1770 2020 2260heatingcapacity kW 6,4 8,1 8,9 10,6 11,7 12,6soundpressurelevelat3m dB(A) 30 36 40 45 49 51
SRV/QS-250-DKnominalunitlength m 2,5 doorheight m 2-2.4electricalsupply V/ph/Hz 230/1/50max.inputcurrent(1phase) A 2,2max.fanpower kW 0,49max.specificfanpower W/l/s 0,63maxheatingcapacity kW 17,3capacityindex 140weightcasingstyleF/R/C kg 113/139/131airinlettemperature °C 20dischargeairtemperature °C 30-45speed 1 2 3 4 5 6airvolume m³/h 1100 1510 1700 2210 2530 2830heatingcapacity kW 8,5 10,9 12 14,5 16 17,3soundpressurelevelat3m dB(A) 31 37 41 46 50 52
SensAirtechnicaldata
DXheatingSRV/QM-100-DKnominalunitlength m 1 doorheight m 2.2-2.8electricalsupply V/ph/Hz 230/1/50max.inputcurrent(1phase) A 1,25max.fanpower kW 0,27max.specificfanpower W/l/s 0,63maxheatingcapacity kW 9,7capacityindex 80weightcasingstyleF/R/C kg 59/69/67airinlettemperature °C 20dischargeairtemperature °C 30-45speed 1 2 3 4 5 6airvolume m³/h 490 740 880 1180 1310 1530heatingcapacity kW 3,9 5,6 6,4 8 8,6 9,7soundpressurelevelat3m dB(A) 25 34 39 45 50 53
SRV/QM-150-DKnominalunitlength m 1,5 doorheight m 2.2-2.8electricalsupply V/ph/Hz 230/1/50max.inputcurrent(1phase) A 1,87max.fanpower kW 0,4max.specificfanpower W/l/s 0,63maxheatingcapacity kW 11,7capacityindex 80weightcasingstyleF/R/C kg 81/97/92airinlettemperature °C 20dischargeairtemperature °C 30-45speed 1 2 3 4 5 6airvolume m³/h 730 1100 1320 1780 1960 2300heatingcapacity kW 5,3 7,2 8,1 9,9 10,6 11,7soundpressurelevelat3m dB(A) 26 35 40 47 51 54
SensAirtechnicaldata
DXheatingSRV/QM-200-DKnominalunitlength m 2 doorheight m 2.2-2.8electricalsupply V/ph/Hz 230/1/50max.inputcurrent(1phase) A 2,49max.fanpower kW 0,54max.specificfanpower W/l/s 0,63maxheatingcapacity kW 15,2capacityindex 100weightcasingstyleF/R/C kg 101/122/116airinlettemperature °C 20dischargeairtemperature °C 30-45speed 1 2 3 4 5 6airvolume m³/h 970 1470 1750 2370 2610 3070heatingcapacity kW 6,9 9,4 10,6 12,9 13,8 15,2soundpressurelevelat3m dB(A) 28 37 42 48 53 56
SRV/QM-250-DKnominalunitlength m 2,5 doorheight m 2.2-2.8electricalsupply V/ph/Hz 230/1/50max.inputcurrent(1phase) A 3,12max.fanpower kW 0,67max.specificfanpower W/l/s 0,63maxheatingcapacity kW 21,1capacityindex 140weightcasingstyleF/R/C kg 125/151/143airinlettemperature °C 20dischargeairtemperature °C 30-45speed 1 2 3 4 5 6airvolume m³/h 1210 1840 2190 2960 3270 3840heatingcapacity kW 9,2 12,7 14,5 17,8 19 21,1soundpressurelevelat3m dB(A) 29 38 43 49 54 57
SensAirtechnicaldata
DXheatingSRV/QL-100-DKnominalunitlength m 1 doorheight m 2.5-3.3electricalsupply V/ph/Hz 230/1/50max.inputcurrent(1phase) A 3,03max.fanpower kW 0,57max.specificfanpower W/l/s 0,66maxheatingcapacity kW 17,1capacityindex 125weightcasingstyleF/R/C kg 72/85/83airinlettemperature °C 20dischargeairtemperature °C 30-45speed 1 2 3 4 5 6airvolume m³/h 1010 1440 1710 2240 2680 3140heatingcapacity kW 7,6 10,1 11,4 13,8 15,5 17,1soundpressurelevelat3m dB(A) 33 40 43 48 53 56
SRV/QL-150-DKnominalunitlength m 1,5 doorheight m 2.5-3.3electricalsupply V/ph/Hz 230/1/50max.inputcurrent(1phase) A 4,55max.fanpower kW 0,86max.specificfanpower W/l/s 0,66maxheatingcapacity kW 25,6capacityindex 200weightcasingstyleF/R/C kg 106/124/121airinlettemperature °C 20dischargeairtemperature °C 30-45speed 1 2 3 4 5 6airvolume m³/h 1510 2160 2560 3360 4020 4720heatingcapacity kW 11,4 15,1 17,1 20,7 23,2 25,6soundpressurelevelat3m dB(A) 34 41 44 50 54 58
SensAirtechnicaldata
DXheatingSRV/QL-200-DKnominalunitlength m 2 doorheight m 2.5-3.3electricalsupply V/ph/Hz 230/1/50max.inputcurrent(1phase) A 6,07max.fanpower kW 1,15max.specificfanpower W/l/s 0,66maxheatingcapacity kW 32,3capacityindex 250weightcasingstyleF/R/C kg 134/159/155airinlettemperature °C 20dischargeairtemperature °C 30-45speed 1 2 3 4 5 6airvolume m³/h 2010 2880 3410 4480 5360 6290heatingcapacity kW 14,9 19,5 22 26,4 29,5 32,3soundpressurelevelat3m dB(A) 36 43 46 51 56 59
SRV/QL-250-DKnominalunitlength m 2,5 doorheight m 2.5-3.3electricalsupply V/ph/Hz 230/1/50max.inputcurrent(1phase) A 7,58max.fanpower kW 1,44max.specificfanpower W/l/s 0,66maxheatingcapacity kW 34,4capacityindex 250weightcasingstyleF/R/C kg 167/199/193airinlettemperature °C 20dischargeairtemperature °C 30-45speed 1 2 3 4 5 6airvolume m³/h 2520 3610 4270 5600 6700 7860heatingcapacity kW 16,9 21,8 24,3 28,7 31,7 34,4soundpressurelevelat3m dB(A) 37 44 47 52 57 60
SensAirtechnicaldata
DXheatingSRV/QXL-100-DKnominalunitlength m 1 doorheight m 3-4electricalsupply V/ph/Hz 230/1/50max.inputcurrent(1phase) A 5,02max.fanpower kW 1,03max.specificfanpower W/l/s 0,94maxheatingcapacity kW 19,6capacityindex 125weightcasingstyleF/R/C kg 76/89/87airinlettemperature °C 20dischargeairtemperature °C 30-45speed 1 2 3 4 5 6airvolume m³/h 1170 1580 2030 2720 3370 3950heatingcapacity kW 8,5 10,8 12,9 15,7 17,9 19,6soundpressurelevelat3m dB(A) 38 42 47 52 57 62
SRV/QXL-150-DKnominalunitlength m 1,5 doorheight m 3-4electricalsupply V/ph/Hz 230/1/50max.inputcurrent(1phase) A 7,53max.fanpower kW 1,54max.specificfanpower W/l/s 0,94maxheatingcapacity kW 29,2capacityindex 200weightcasingstyleF/R/C kg 112/130/127airinlettemperature °C 20dischargeairtemperature °C 30-45speed 1 2 3 4 5 6airvolume m³/h 1750 2370 3050 4090 5060 5920heatingcapacity kW 12,8 16,2 19,3 23,4 26,7 29,2soundpressurelevelat3m dB(A) 39 44 48 54 59 63
SensAirtechnicaldata
DXheatingSRV/QXL-200-DKnominalunitlength m 2 doorheight m 3-4electricalsupply V/ph/Hz 230/1/50max.inputcurrent(1phase) A 10,04max.fanpower kW 2,05max.specificfanpower W/l/s 0,94maxheatingcapacity kW 36,4capacityindex 250weightcasingstyleF/R/C kg 143/168/164airinlettemperature °C 20dischargeairtemperature °C 30-45speed 1 2 3 4 5 6airvolume m³/h 2330 3170 4060 5450 6740 7890heatingcapacity kW 16,7 20,9 24,7 29,7 33,6 36,4soundpressurelevelat3m dB(A) 41 45 50 55 60 65
SRV/QXL-250-DKnominalunitlength m 2,5 doorheight m 3-4electricalsupply V/ph/Hz 230/1/50max.inputcurrent(1phase) A 12,55max.fanpower kW 2,57max.specificfanpower W/l/s 0,94maxheatingcapacity kW 38,3capacityindex 250weightcasingstyleF/R/C kg 176/208/202airinlettemperature °C 20dischargeairtemperature °C 30-45speed 1 2 3 4 5 6airvolume m³/h 2920 3960 5080 6810 8430 9870heatingcapacity kW 18,8 23,2 27,1 31,9 35,6 38,3soundpressurelevelat3m dB(A) 42 46 51 56 61 66
SensAirdimensionalsketches
Freehangingmodel
SensAirdimensionalsketches
Recessedmodel
SensAirdimensionalsketches
Cassettemodel
SensAirdimensionalsketches
WallsuspensionbracketsStandard
Design
Threadedrodcovers
SizeHisthedistancebetweenunitandceiling.Thissizeneedstobecommunicatedontheorder.
SensAirdimensionalsketches
ConnectionsDX
Dimensionalsketches
IndexThecorrespondingnumbersinthedimensionalsketchesareexplainedbelow:
3-Airinletgrillewithfilter
20-Connectionplate
35-Ductsarenotsupplied
43-Finishingsectionssuppliedseparately
36-EyeboltM6
12-Pipework
87-Threadedrodcovers(positionisflexible)
17-ConnectionDaikinunits
46-Fluidconnection
49-Gasconnection
50-Gland
ExplanationdimensionalsketchesModelsFreehanging:byremovingtheendpanels,theunitsareeasytointerlink.
Cassette:daylightopeningifcovermoldingsareusedinasuspendedceiling=(A+8)x(C+8)mm.
Recessed:daylightopeningsifcovermoldingsareused:
-forairdischarge(A+8)x(D+8)mm
-forairinlet:(A+8)x(I+8)mm
Iftherecessedmodelistobebuiltintoacove,itisalsoavailableinadesignthathasnoinletairplenumorflexibleducts.To
preventbadairfromletin,thecovewillneedtobeair-tight.
Wallsuspensionbracketsandthreadedrodcovers
•SizeHisthedistancebetweenunitandceiling.Thissizeneedstobecommunicatedontheorder.
•Materialthreadedrodcovers:zinkcoatedplatesteel,painted,standardcolourRAL9016andRAL9006.
Note•Alldimensionsareinmm.
•SensAir2500mmunitshave3suspensionbrackets.Allothersizeshave2suspensionbrackets.
Notes
Notes
Notes
Notes
Subjecttochangewithoutpriornotice
BiddleAirSystemsLimitedSt.Mary’sRoad
WarwickshireCV115AUNuneaton
T+442476384233
Iwww.biddle-air.co.uk