DVM MINI. Expand Line Up (4 Model 6 Model) Conventional Model New Model Capacity4HP5HP6HP 1...

10
DVM MINI

Transcript of DVM MINI. Expand Line Up (4 Model 6 Model) Conventional Model New Model Capacity4HP5HP6HP 1...

Page 1: DVM MINI. Expand Line Up (4 Model  6 Model) Conventional Model New Model Capacity4HP5HP6HP 1 Phase●● 3 Phase●● Capacity4HP5HP6HP 1 Phase●●● 3 Phase●●●

DVM MINI

Page 2: DVM MINI. Expand Line Up (4 Model  6 Model) Conventional Model New Model Capacity4HP5HP6HP 1 Phase●● 3 Phase●● Capacity4HP5HP6HP 1 Phase●●● 3 Phase●●●

Expand Line Up (4 Model 6 Model)

Conventional ModelConventional ModelConventional ModelConventional Model New ModelNew ModelNew ModelNew Model

Capacity 4HP 5HP 6HP

1 Phase ● ●

3 Phase ● ●

Capacity 4HP 5HP 6HP

1 Phase ● ● ●

3 Phase ● ● ●

Combined up to 9 indoor units blending with any interior design

Controlled with control systems which is the same as DVM PLUS Ⅳ

Page 3: DVM MINI. Expand Line Up (4 Model  6 Model) Conventional Model New Model Capacity4HP5HP6HP 1 Phase●● 3 Phase●● Capacity4HP5HP6HP 1 Phase●●● 3 Phase●●●

Top Class Energy Efficiency & Low Sound Level

Better energy efficiency than competitor’s model in all range

Low sound level same as competitor’s model

AVR. Energy Efficiency AVR. Energy Efficiency AVR. Energy Efficiency AVR. Energy Efficiency

2.0

3.0

3.5

4.0

4.5

5.0

2.5

4HP 5HP 6HP 4HP 5HP1.5

6HP

D S

1 Phase 3 Phase

Sound LevelSound LevelSound LevelSound Level

51

53

4HP 5HP 6HP

D S

1/3 Phase

50

Page 4: DVM MINI. Expand Line Up (4 Model  6 Model) Conventional Model New Model Capacity4HP5HP6HP 1 Phase●● 3 Phase●● Capacity4HP5HP6HP 1 Phase●●● 3 Phase●●●

Level difference50m

The longest piping length150 m

Flexible piping design

Extended piping length up to 150m and maximum level difference of 50m.

Page 5: DVM MINI. Expand Line Up (4 Model  6 Model) Conventional Model New Model Capacity4HP5HP6HP 1 Phase●● 3 Phase●● Capacity4HP5HP6HP 1 Phase●●● 3 Phase●●●

Small Footprint and Volume

Footprint of new model has been decreased by 11%

and the volume has been decreased by 5% compared to conventional model.

Page 6: DVM MINI. Expand Line Up (4 Model  6 Model) Conventional Model New Model Capacity4HP5HP6HP 1 Phase●● 3 Phase●● Capacity4HP5HP6HP 1 Phase●●● 3 Phase●●●

Flexible pipe installation

The service valve can be attached from 4 different directions for seamless installation.

6

New OutdoorNew OutdoorNew OutdoorNew OutdoorConventionalConventionalConventionalConventional

Page 7: DVM MINI. Expand Line Up (4 Model  6 Model) Conventional Model New Model Capacity4HP5HP6HP 1 Phase●● 3 Phase●● Capacity4HP5HP6HP 1 Phase●●● 3 Phase●●●

TOP Class Energy Efficiency

Achieve top class energy efficiency (Avg. 4.1) with TBR Compressor & New Fan

← same as new CAC outdoor.

7

Improved CompressorImproved CompressorImproved CompressorImproved Compressor Improved Fan ShapeImproved Fan ShapeImproved Fan ShapeImproved Fan Shape

11.1

11.2

11.3

11.4

11.0

11.5

11.6

11.7

11.611.611.311.3

(Btu/Wh)

NEW Conventional

Page 8: DVM MINI. Expand Line Up (4 Model  6 Model) Conventional Model New Model Capacity4HP5HP6HP 1 Phase●● 3 Phase●● Capacity4HP5HP6HP 1 Phase●●● 3 Phase●●●

Low vibration TBR compressor_1

Reduce 80% vibration with TBR(Twin BLDC) compared to single compressor

Single Compressor Twin Compressor

0

20

40

60

80

100

Vibration

Vibration

• Small Capacity • Large Capacity

Page 9: DVM MINI. Expand Line Up (4 Model  6 Model) Conventional Model New Model Capacity4HP5HP6HP 1 Phase●● 3 Phase●● Capacity4HP5HP6HP 1 Phase●●● 3 Phase●●●

Low vibration and uniform torque in all range due to have symmetry cam

compared to single compressor (asymmetric cam) .

Low vibration TBR compressor_2

Page 10: DVM MINI. Expand Line Up (4 Model  6 Model) Conventional Model New Model Capacity4HP5HP6HP 1 Phase●● 3 Phase●● Capacity4HP5HP6HP 1 Phase●●● 3 Phase●●●

Thank you