The bathroom and WC; a place where we need privacy and comfort. These are areaswhere odours and humidity can occur. This is the world where Gonal’s Technology canhelp; sometimes seen, sometimes not.Gonal’s ducting systems for extraction and air renewal ensures air quality within thehome. Using the latest technology to give you high performance that is both quiet andeffective.
We spend a lot of time in the kitchen preparing and cooking food, naturally smells andfumes are created. Extracting them to the outside of your home is the responsibility ofGonal’s Ducting Systems.Gonal has the largest ducting range available, and can offer maximum performancein extracting smells and fumes with products suitable for every extractor hood in themarket.
ducting systems for ventilation and extraction
PRODUCTS INDEX
3
WALL OUTLETS WINDOWSAND GRILLES FOR VENTILATION
18
KITS FOR EXTRACTION 20
FLEXIBLE HOSE 21
SOUNDPROOF PIPE 22
FLAME RETARDANT SYSTEM 22
EXTRACTOR FAN 23
24
TELESCOPIC SYSTEMS FOR VENTILATION 16
FLEXIBLE ELBOWS 17
DUCTING SYSTEMSFOR VENTILATION AND EXTRACTION 6
CHARACTERISTICS OF GONAL SYSTEMS 5
TECHNICAL INFORMATION 4
MULTIFORM WC 26
ISO 9001 CERTIFICATE 27
TECHNICAL INFORMATION
4
It is essential to make the flow calculation of the area to be ventilated, to make the correct choice of GONALducting system.This ca lcu lation is made by multiplying the volume by the ACH (air changes per hour)Plea se, se e a tta ched chart w it h some examp les a ccording to t he cur rent regula tions .To assure a clean air environment, always use the appropriate fan for your ventilation requirements.By us ing a superio r GONAL syst em y ou wil l be prepa red f or any un fo reseen demand .
Room Air changes Example Room volume Necessary Recommendedper Hour Flow System
Technical Information is available for ventilation system designers, specifiers and installers to assist you inchoosing the optimum GONAL system, assuring the lowest resis tance with the best performance.To ensure the correct ventilation/ extraction current bui lding regulations demand that you take into accountdifferent factors. Those are extractor ventilation fan, the extraction and flow ratio (l/s o m
3/h), ducting circuit
configuration, i ts length, pressure loss(Pa),etc.
• Non Domestic building• Without window• Same conditions with extractor fan, with 15 minutes automatic overrun or manual control or occupant detecting.• All new domestic buildings and extensions must comply with F1 building regulations and provide ventilation in
kitchens, utility rooms, bathrooms and WCs.
• Domestic building• Without window• Same conditions with extractor fan, with 15 minutes automatic overrun.
Room Rapid ventilation Background ventilation Extractor fan
Habitable room 1/20 of floor area< 10 m2 4.000 m2 Non-smoking area 8 l/s/pers.
< 10 m2 4.000 mm2 Smoking area 16 l/s/pers.
KitchenWindow 4.000 mm2 30 l/s near worktop
Domestic Type 60 l/s elsewhere
Bathroom Window 4.000 mm2 15 l/s
Toilet room 1/20 of floor area 4.000 mm2 6 l/s/wc or 3 ACH
Room Rapid ventilation Background ventilation Extractor fan
Habitable room 1/20 of floor area 8.000 mm2 -
Kitchen Window 4.000 mm2 30 l/s near worktop
Utility room Window 4.000 mm2 15 l/s
Toilet room Window 4.000 mm2 -
Bathroom Window 4.000 mm2 15 l/s
AN OPTIMUM SYSTEM FOR EACH NEED
volume = a x b x c = m3
ab
c
Room 2-4 ACHRoom
5 x 3 x 2,60 = 39m 3 from 78 m3/h System 100 (600)5 x 3 x 2,6 m
Kitchen 10-15 ACHKitchen
5 x 4 x 2,60 = 52m3 from 780 m 3/h System 150 (SUPRA)5 x 4 x 2,60 m
15-20 ACH Utility room 4 x 3 x 2,60 = 31,2m 3 from 468 m3/h System 120 (800)Utility room 4 x 3 x 2,60 m System 125 (DUPLA)
Bathroom12-16 ACH
Bathroom4 x ,4 x 2,40 = 38,4m3 from 230 m 3/h
System 120 (800)4 x 4 x 2,40 m System 125 (DUPLA)
Toilet room3-10 ACH
Toilet room3 x 2 x 2,40 = 14,4m 3 from 144 m3/h System 100 (600)3 x 2 x 2,40 m
CHARACTERISTICS OF GONAL SYSTEMS
5
SERIE 500 600 800 DUPLA SUPRA
SISTEMA 100 100 120 125 150
RECTANGULAR DUCTINGDimension mm 55 x 110 60 x 120 75 x 150 55 x 220 90 x 180
Cross section mm2 5565 6669 10584 11284 15399
ROUND DUCTINGDimension mm Ø 100 Ø 100 Ø 120 Ø 125 Ø 150Cross section mm2 7850 7850 11304 12265 17660
Flow rate (m3/h)* < 300 < 300 300 - 550 550 - 650 > 650
* Orientative
SPECIFICATIONS
EXTRACTION VENTILATION
• Made of self-extinguishing material
• Maximum working temperature of 80° C
• For flows from 250 to 1250 m3/h
• Easy and quick assembly
• A wide range of accessories enables a large versatility
• Hermetic closure guaranteed
• Modular assembly without need of silicons or adhesives
• 92% of ventilation efficiency
Flat channel
Code Dimensions
SU-2002/1 90 x 180 / L=1000 9 mSU-2002 90 x 180 / L=1500 13,5 mSU-2002/3 90 x 180 / L=3000 6 m
Round to rectangular adapter
Round pipe
Code Dimensions (mm)
SU2005/1 Ø 150 / L=1000 5 mSU2005 Ø 150 / L=1500 7,5 mSU2005/3 Ø 150 / L=3000 6 m
Rectangular flat connector
Code Dimensions (mm)
SU2020 90 x 180 16 u.
Code Dimensions (mm)
SU2040 Ø 150 to 90 x 180 20 u.
Vertical mixed 90º elbow
Code Dimensions (mm)
SU2050 Ø 150 to 90 x 180 4 u.
Vertical rectangular 90° elbow
Code Dimensions (mm)
SU2060 90 x 180 5 u.
Horizontal rectangular 90° elbow
Code Dimensions (mm)
SU2070 90 x 180 4 u.
Round wall plateCode Dimensions (mm)
SU2045 Ø 150 36 u.
Rectangular flat channel wall outlet
Code Dimensions (mm)
SU2100 90 x 180 10 u.
Metallic rectangular clamp
Code Dimensions (mm)
SU2110 90 x 180 25 u.
Round connector
Code Dimensions (mm)
SU2030 Ø 150 10 u.
Round flexible elbow
Code Dimensions (mm)
CRF-150C Ø 150 / L=500 3 u.
Round louvred grilleCode Dimensions (mm)
SU2052 Ø 150 18 u.
Flat channel wall plate
Code Dimensions (mm)
SU2090 90 x 180 25 u.
Round elbow 90° elbow
Code Dimensions (mm)
SU2075 Ø 150 5 u.
Rectangular flexible elbow
Code Dimensions (mm)
CCF-900-C 90 x 180 / L=500 3 u.
SERIE SUPRASYSTEM 150 DUCTING SYSTEMS FOR VENTILATION AND EXTRACTION
6
Reducer cone
Round louvred grilleCode Dimensions
0464 Ø 150 25 u.
7
Round flexible hose
Code Dimensions
0690/1 Ø 150 / L=1000 40 u.0690/3 Ø 150 / L=3000 20 u.0690/6 Ø 150 / L=6000 1 0 u.
Internal damperCode Dimensions
SU2031 Ø 150 15 u.
Characteristics of GONAL systemsSUPRA SYSTEM / 150 mm
• We recommend pipe diameters to suit your extractionvolume requirements as per IEC 61591standards.
• Made of self-extinguishing material.
• Maximum working temperature of 80° C.
• For flows from 650 m3/h.
• Easy and quick assembly.
• A wide range of accessories for maximum versatility.
• Hermetic closure guaranteed.
• Modular assembly does not require sealant or adhesive.
• 92% of ventilation efficiency.
Code Dimensions
SU2065 Ø 150 to 125 30 u.
The diameter of intakepipe must not be less than150 mm.
Motors for air flows of more of 650 m3/h Ø 150 mm
• The sizes of all series are expressed in mm.
SERIE DUPLASYSTEM 125 DUCTING SYSTEMS FOR VENTILATION AND EXTRACTION
8
Reducer cone Ø 125 to Ø 100
Code Dimensions
T-P 1300 Ø 125 to 100 25 u.
Round to rectangular adapter
Round pipe
Code Dimensions
T-P 1005/1 Ø 125 / L=1000 7 mT-P 1005 Ø 125 / L=1500 10,5 mT-P 1005/3 Ø 125 / L=3000 12 m
Rectangular flat connector
Code Dimensions
T-P 1020 55 x 220 24 u.
Round connector
Code Dimensions
T-P 1030 Ø 125 24 u.
Code Dimensions
T-P 1040 Ø 125 to 55 x 220 10 u.
Vertical mixed 90° elbow
Code Dimensions
T-P 1050 Ø 125 to 55 x 220 24 u.
Vertical rectangular 90° elbow
Code Dimensions
T-P 1060 55 x 220 20 u.
Horizontal rectangular 45° elbow
Code Dimensions
T-P 1075 55 x 220 18 u.
Flat channel wall plate
Code Dimensions
T-P 1090 55 x 220 25 u.
Metallic rectangular clamp
Code Dimensions
T-P 1110 55 x 220 25 u.
Round flexible elbowCode Dimensions
CRF-125-C Ø 125 / L=500 4 u.
Rectangular flexible elbow
Code Dimensions
CCF-1000-C 55 x 220 / L=500 3 u.
Orientative vertical mixed 90° elbow
Code Dimensions
T-P 1025 Ø 125 to 55 x 220 10 u.
Rectangular flat channel wall outlet
Rectangular flat channel wall outlet
Rectangular flat channel wall outlet
Code Dimensions Finish
T-P 1100S 55 x 220 Sandstone 24 u.
Code Dimensions Finish
T-P 1100T 55 x 220 Brick / Terracota 24 u.
Code Dimensions Finish
T-P 1100 55 x 220 White 24 u.
Horizontal rectangular 90° elbow
Code Dimensions
T-P 1070 50 x 220 12 u.
Round 90° elbowCode Dimensions
T-P 1500 Ø 125 10 u.
Reducer coneCode Dimensions
0860 Ø 125 to 120 22 u.
Multi cone reducer
Code Dimensions
0660 Ø 125 to 100 40 u.
Metallic round clampCode Dimensions
0857 Ø 120 25 u.
Flat channel
Code Dimensions Piezas
T-P-1002/1 55 x 220 / L=1000 9 mT-P-1002 55 x 220 / L=1500 13,5 mT-P-1002/3 55 x 220 / L=3000 12 m
Rectangular end cap
Code Dimensions
TPC-2 55 x 220 24 u.
Mixed T-joint
Code Dimensions
T-2 55 x 220 x L=300 Ø 125 8 u.
9
Characteristics of GONAL systemsDUPLA SYSTEM / 125 mm
Round flexible hoseCode Dimensions
0689/1,5 Ø 127 / L=1500 60 u.0689/3 Ø 127 / L=3000 30 u.0689/6 Ø 127 / L=6000 15 u.
Internal damperCode Dimensions
T-P 1031 Ø 125 15 u.
Round T-jointCode Dimensions
TR-125 Ø 125 4 u.
Rectangular T-joint
Code Dimensions
TT-4 55 x 220 12 u.
Round louvred grille
Code Dimensions
T-P 1200 Ø 125 10 u.
• We recommend pipe diameters to suit your extractionvolume requirements as per IEC 61591standards
• Made of self-extinguishing material.
• Maximum working temperature of 80° C.
• For flows from 550 to 650 m3/h.
• Easy and quick assembly.
• A wide range of accessories for maximum versatility.
• Hermetic closure guaranteed.
• Modular assembly does not require sealant or adhesive.
• 92% of ventilation efficiency.
The diameter of intake pipemust not be less than 125mm.
Motors for air flows between 550 to 650 m3/h Ø 125 mm
Reducer 45º elbow
Code Dimensions
T-P 1545 55 x 220 10 u.
Rubber joint
Code Dimensions
T-P 1115 Ø 125 1 u.
SERIE 800SYSTEM 120 DUCTING SYSTEMS FOR VENTILATION AND EXTRACTION
10
Round to rectangular adapter
Flat Channel*
Code Dimensions
0801/1 75 x 150 / L=1000 9 m0801 75 x 150 / L=1500 13,5 m0801/3 75 x 150 / L=3000 12 m
Rectangular flat connector
Code Dimensions
0810 75 x 150 27 u.0810-B 75 x 150 24 u.
Round connector
Code Dimensions
0815 Ø 120 24 u.0815-B Ø 120 26 u.
Code Dimensions
0820 Ø 120 to 75 x 150 28 u.0820-B Ø 120 to 75 x 150 6 u.
Vertical mixed 90º elbow
Code Dimensions
0826 Ø 120 to 75 x 150 34 u.0826-B Ø 120 to 75 x 150 6 u.
Vertical rectangular 90° elbow
Code Dimensions
0830 75 x 150 38 u.0830-B 75 x 150 9 u.
Horizontal rectangular 45° elbow
Code Dimensions
0875 75 x 150 36 u.
Flat channel wall plate
Code Dimensions
0840 75 x 150 25 u.0840-TB 75 x 150 50 u.
Round wall plate
Code Dimensions
0845 Ø 120 25 u.0845-TB Ø 120 50 u.
Rectangular flat channel wall outlet
Code Dimensions
0850 75 x 150 20 u.0850-B 75 x 150 20 u.
Round louvred grille
Code Dimensions
0852 Ø 120 18 u.0852-B Ø 120 16 u.
Metallic rectangular clamp
Code Dimensions
0855 75 x 150 25 u.0855-TB 75 x 150 50 u.
Metallic round clamp
Code Dimensions
0857 Ø 120 25 u.0857-TB Ø 120 50 u.
Horizontal rectangular 90º elbow
Code Dimensions
0835 75 x 150 24 u.0835-B 75 x 150 5 u.
Round 90° elbowCode Dimensions
0870 Ø 120 22 u.0870-B Ø 120 6 u.
Round flexible elbowCode Dimensions
CRF-120-C Ø 120 / L=500 4 u.CRF-120-B Ø 120 / L=500 6 u.
Rectangular flexible elbow
Code Dimensions
CCF-800-C 75 x 150 / L=500 8 u.CCF-800-B 75 x 150 / L=500 6 u.
Round 45° elbowCode Dimensions
0876 Ø 120 22 u.
Mixed round flexible elbow
Code Dimensions
CMF-120-C Ø 120 to 75 x 150 / L=500 4 u.
Mixed rectangular flexible elbow
Code Dimensions
CMF-800-C 75 x 150 to Ø 120 / L= 500 4 u.
Round pipe*
Code Dimensions
0805/1 Ø 120 / L=1000 8 m0805 Ø 120 / L=1500 12 m0805/3 Ø 1 20 / L=3000 12 m
Cone reducerCode Dimensions
0860 Ø 125 to 120 22 u.0860-B Ø 125 to 120 23 u.
11
Characteristics of GONAL systems800 SYSTEM / 120 mm
Round flexible hose*Code Dimensions
0689/1,5 Ø 127 / L=1500 60 u.0689/3** Ø 127 / L=3000 30 u.0689/6 Ø 127 / L=6000 15 u.
Multi-cone reducerCode Dimensions
0660 Ø 125 to 100 40 u.
Rectangular flexible hose
Code Dimensions
PR-800 75 x 150 / L=1000 4 u.
Internal damperCode Dimensions
0816 Ø 120 16 u.
Rectangular T-joint
Code Dimensions
TT-3 75 x 150 10 u.
Embedded inner grille
Code Dimensions
0595 Ø 120 25 u. • We recommend pipe diameters to suit your extractionvolume requirements as per IEC 61591standards
• Made of self-extinguishing material.
• Maximum working temperature of 80° C.
• For flows from 300 to 550 m3/h.
• Easy and quick assembly.
• A wide range of accessories for maximum versatility.
• Hermetic closure guaranteed.
• Modular assembly does not require sealant or adhesive.
• 92% of ventilation efficiency.
The diameter of intakepipe must not be less than120 mm.
Motors for air flows from 300 a 550 m3/h Ø 120 mm
(*) Including (-B) at these codes you will receive the items with bar code.(**) Code 0688/3-B is packaged in 8 units.
Codes ended in ( - B )refers toINNOVATIVE EXPOGONAL
see page 26/27
SERIE 600SYSTEM 100 DUCTING SYSTEMS FOR VENTILATION AND EXTRACTION
12
Round to rectangular adapter
Round pipe*
Code Dimensions
0605/1 Ø 100 / L=1000 8 m0605 Ø 100 / L=1500 12 m0605/3 Ø 100 / L=3000 18 m
Rectangular flat connector
Code Dimensions
0610 60 x 120 56 u.0610-B 60 x 120 58 u.
Round connector
Code Dimensions
0615 Ø 100 40 u.0615-B Ø 100 45 u.
Code Dimensions
0620 Ø 100 to 60 x 120 48 u.0620-B Ø 100 to 60 x 120 16 u.
Vertical mixed 90° elbow
Code Dimensions
0625 Ø 100 to 60 x 120 50 u.0625-B Ø 100 to 60 x 120 16 u.
Vertical rectangular 90° elbow
Code Dimensions
0630 60 x 120 64 u.0630-B 60 x 120 19 u.
Horizontal rectangular 45° elbow
Code Dimensions
0671 60 x 120 20 u.
Horizontal rectangular 90° elbow
Code Dimensions
0635 60 x 120 45 u.0635-B 60 x 120 12 u.
Flat channel wall plate
Code Dimensions
0640 60 x 120 25 u.0640-TB 60 x 120 50 u.
Round-round “embellish” wall plate
Round wall plate
Code Dimensions
0645 Ø 100 25 u.0645-TB Ø 100 50 u.
Rectangular flat channel wall outlet
Code Dimensions
0652 60 x 120 20 u.0652-B 60 x 120 20 u.
Round louvred grille
Code Dimensions
0653 Ø 100 30 u.
Metallic rectangular clamp
Code Dimensions
0655 60 x 120 25 u.0655-TB 60 x 120 50 u.
Metallic round clamp
Code Dimensions
0656 Ø 100 25 u.0656-TB Ø 100 50 u.
Code Dimensions
0565 Ø 100 a Ø 100 24 u.
Flat channel*
Code Dimensions
0601/1 60 x 120 / L=1000 10 m0601 60 x 120 / L=1500 15 m0601/3 60 x 120 / L=3000 18 m
Rectangular flat channel wall outlet
Code Dimensions
0550-M Ø 100 / 55 x 110 - Brown 30 u.0550 Ø 100 / 55 x 110 - White 30 u.0550-B Ø 100 / 55 x 110 - White 24 u.
Round 90° elbowCode Dimensions
0670 Ø 100 36 u.0670-B Ø 100 11 u.
Round 45° elbowCode Dimensions
0676 Ø 100 36 u.
Round flexible elbow
Code Dimensions
CRF-100-C Ø 100 / L=500 8 u.CRF-100-B Ø 100 / L=500 9 u.
Rectangular flexible elbow
Code Dimensions
CCF-600-C 60 x 120 / L=500 4 u.CCF-600-B 60 x 120 / L=500 3 u.
Cone reducerCode Dimensions
0665 Ø 120 to 100 36 u.
13
Characteristics of GONAL systems600 SYSTEM / 100 mm
Round flexible hose*Code Dimensions
0688/2 Ø 102 / L=2000 60 u.0688/3** Ø 102 / L=3000 45 u.0688/6 Ø 102 / L=6000 30 u.
Internal damperCode Dimensions
0616 Ø 100 20 u.
Round T-Joint
Code Dimensions
TR-100 Ø 100 12 u.
Embedded grilleCode Dimensions
0463 Ø 100 25 u.
Multi cone reducerCode Dimensions
0660 Ø 125 to 100 40 u.0660-B Ø 125 to 100 56 u.
• We recommend pipe diameters to suit your extractionvolume requirements as per IEC 61591standards
• Made of self-extinguishing material.
• Maximum working temperature of 80° C.
• For flows from 300 m3/h
• Easy and quick assembly.
• A wide range of accessories for maximum versatility.
• Hermetic closure guaranteed.
• Modular assembly does not require sealant or adhesive.
• 92% of ventilation efficiency.
The diameter of intakepipe must not be less than100 mm.
Motors for air flows up to 300 m3/h Ø 100 mm
(*) Including (-B) at these codes you will receive the items with bar code.(**) Code 0688/3-B is packaged in 8 units.
Codes ended in ( - B )refers toINNOVATIVE EXPOGONAL
see page 26/27
Round to rectangular adapter
Rectangular flat connector
Code Dimensions
0510 55 x 110 66 u.0510-B 55 x 110 72 u.
Round connector
Code Dimensions
0615 Ø 100 40 u.0615-B Ø 100 45 u.
Code Dimensions
0520 Ø 100 to 55 x 110 36 u.0520-B Ø 100 to 55 x 110 16 u.
Vertical mixed 90° elbow
Code Dimensions
0525 Ø 100 to 55 x 110 45 u.0525-B Ø 100 to 55 x 110 18 u.
Rectangular vertical 90° elbow
Code Dimensions
0530 55 x 110 70 u.0530-B 55 x 110 24 u.
Horizontal rectangular 45° elbow
Code Dimensions
0570 55 x 110 20 u.0570-B 55 x 110 24 u.
Flat channel wall plate
Code Dimensions
0540 55 x 110 25 u.0540-TB 55 x 110 50 u.
Rectangular-round “embellish” wall plate
Code Dimensions
0545 Ø 100 to 55 x 110 24 u.
Round-round “embellish” wall plate
Code Dimensions
0565 Ø 100 to Ø 100 24 u.
Round louvred grille
Code Dimensions
0550 Ø 100 / 55 x 110 - White 30 u.0550-B Ø 100 / 55 x 110 - White 30 u.
Flat channel*
Code Dimensions
0501/1 55 x 110 / L=1000 12 m0501 55 x 110 / L=1500 18 m0501/3 55 x 110 / L=3000 18 m
Round pipe*Code Dimensions
0605/1 Ø 100 / L=1000 8 m0605 Ø 100 / L=1500 12 m0605/3 Ø 100 / L=3000 18 m
Horizontal rectangular 90° elbow
Code Dimensions
0535 55 x 110 48 u.0535-B 55 x 110 15 u.
Round 90° elbowCode Dimensions
0670 Ø 100 36 u.0670-B Ø 100 11 u.
Round 45° elbow
Code Dimensions
0676 Ø 100 36 u.
Rectangular flexible elbow
Code Dimensions
CCF-500-C 55 x 110 / L=500 8 u.CCF-500-B 55 x 110 / L=500 10 u.
Mixed round flexible elbow
Code Dimensions
CMF-100-C Ø 100 to 55 x 110 / L=500 4 u.
Mixed rectangular flexible elbow
Code Dimensions
CMF-500-C 55 x 110 to Ø 100° / L=500 4 u.
Round louvred grille
Code Dimensions
0550-M Ø 100 / 55 x 110 - Brown 30 u.
Round flexible elbowCode Dimensions
CRF-100-C Ø 100 / L=500 8 u.CRF-100-B Ø 100 / L=500 9 u.
Embedded grilleCode Dimensions
0463 Ø 100 25 u.
SERIE 500SYSTEM 100 DUCTING SYSTEMS FOR VENTILATION AND EXTRACTION
14
Round wall plate
Code Dimensions
0645 Ø 100 25 u.0645-B Ø 100 50 u.
Metallic rectangular clamp
Code Dimensions
0555 55 x 110 25 u.0555-TB 55 x 110 50 u.
Metallic round clampCode Dimensions
0656 Ø 100 25 u.0656-TB Ø 100 50 u.
Mixed T-jointCode Dimensions
T-1 55 x 110 x 300 Ø 100 12 u.
15
Characteristics of GONAL systems500 SYSTEM / 100
Round T-JointCode Dimensions
TR-100 Ø 100 12 u.
Rectangular T-joint
Code Dimensions
TT-2 55 x 110 9 u.
Round flexible hose*Code Dimensions
0688/2 Ø 102 / L=2000 60 u.0688/3** Ø 102 / L=3000 45 u.0688/6 Ø 102 / L=6000 30 u.
Rectangular flexible hose
Code Dimensions
PR-500 55 x 110 /L=1000 4 u.
Internal damperCode Dimensions
0616 Ø 100 20 u.
Multi cone reducerCode Dimensions
0660 Ø 125 to 100 40 u.0660-B Ø 125 to 100 56 u.
Rectangular end cap
Code Dimensions
TPC-1 55 x 110 25 u.
• We recommend pipe diameters to suit your extractionvolume requirements as per IEC 61591standards
• Made of self-extinguishing material.
• Maximum working temperature of 80° C.
• For flows from 300 m3/h
• Easy and quick assembly.
• A wide range of accessories for maximum versatility.
• Hermetic closure guaranteed.
• Modular assembly does not require sealant or adhesive.
• 92% of ventilation efficiency.
The diameter of intakepipe must not be lessthan 100 mm.
Motors for air flows up to 300 m3/h Ø 100 mm
(**) Code 0688/3-B is packaged in 8 units.
Codes ended in ( - B )refers toINNOVATIVE EXPOGONAL
see page 26/27
(*) Including (-B) at these codes you will receive the items with bar code.
TELESCOPIC SYSTEMS FOR VENTILATION
16
• Necessary to guarantee a room air renovation, from inside to outside.
• The external grille shape assure the non-return of air
• Compatible with our rigid ducting pipes.
SVD 100 Direct System interior / exterior
Exterior wall outlet grille Ø 100 mm 1 100 300 m3/h
Telescopic pipe 180 -360 1
Exterior wall grille 1
SVD 125 Direct System interior / exterior
Exterior wall outlet grille Ø 125 mm 1 125 300-550 m3/h
Telescopic pipe 180 - 360 1
Exterior wall grille 1
STT 100 Telescopic system 100
Wall outlet with internal damper 1 100 300 m3/h
Telescopic pipe 250 - 450 mm 1
Wall outlet window 1
STT 125 Telescopic system 125
Wall outlet with internal damper 1 125 300-550 m3/h
Telescopic pipe 250 - 450 mm 1
Wall outlet window 1
INTERIOR-EXTERIOR SYSTEM
STT 150 Telescopic system 150
Wall outlet with internal damper 1 150 > 650 m3/h
Telescopic pipe 250 - 450 mm 1
Wall outlet window 1
• We supply telescopic systems according to your needs. Please ask for them!
PHOTOGRAPH Code Description System Air flow
SYSTEM CONNECTION
PHOTOGRAPH Code Description System Air flow
FLEXIBLE ELBOWS
17
CRF-100-C Round flexible elbow Ø 100 mm 500 8
CRF-120-C Round flexible elbow Ø 120 mm 800 4
CRF-125-C Round flexible elbow Ø 125 mm DUPLA 4
CRF-150-C Round flexible elbow Ø 150 mm SUPRA 3
PHOTOGRAPH Code Description System
CCF-500-C Rectangular flexible elbow 55 x 110 mm 500 8
CCF-800-C Rectangular flexible elbow 75 x 150 mm 800 8
CCF-1000-C Rectangular flexible elbow 55 x 220 mm DUPLA 3
CCF-900-C Rectangular flexible elbow 90 x 180 mm SUPRA 4
CMF-100-C Mixed round flexible elbow Ø 100 to 55 x 110 mm 500 4
CMF-120-C Mixed round flexible elbow Ø 120 to 75 x 150 mm 800 4
CMF-500-C Mixed rectangular flexible elbow 55 x 110 to Ø 100 mm 500 4
CMF-800-C Mixed rectangular flexible elbow 75 x 150 to Ø 100 mm 800 4
• QUICK ASSEMBLY• EASY HANDLING• TOTAL COMPATIBILITY
CCF600-C Rectangular flexible elbow 60 x 120 mm 600 3
ADAPTABLE AND EASY TO INTEGRATE
TO ANY INSTALLATION
Variable angles from 0 to 90°
WALL OUTLETS AND GRILLES FOR VENTILATION
18
The ventilation is one of the requirements of a modern home, for this reasonGONAL offers a range of wall outlets and grilles for ventilation... practical,easy to assemble with a proven efficiency in the market.
BS 493: Airbriks and gratings for ventilation meet Standard BS 493.
We supply telescopic systems according to your needs.
WHITE COLOUR
Our range of wall outlets grilles can be installed both inside an out forapplications such as bathrooms, kitchens, utility rooms, and other areaswhich need air renewal.
PRODUCT Code Dimension/mm Air movement /cm2
0463 Ø inner grille 96* 40 25 u.
0464 Ø inner grille 156* 135 25 u.
0595 Ø inner grille 121* 100 25 u.
PRODUCT Code Dimension/mm Air movement /cm2
0592 Ø 90 - 140* 100 25 u.
0593 Ø 125 - 160* 140 25 u.
• Versatile grilles, one grille for all diameters.
*Grilles adaptable to ducting systems with diameters of 90/125 and 140/160
PLASTIC GRILLES SURFACE MOUNTED
EMBEDDED PLASTIC GRILLES
PRODUCT Code Dimension /mm Air movement/cm2
0596
183 x 154
60 20 u.(with pegs)
(Ø 80 - 140)
0460 150 x 200 140 52 u.
0461 230 x 230 210 60 u.
0462 230 x 430 420 32 u.
PLASTIC FIXED GRILLES
19
0465 150 x 150 140 25 u.
0466 170 x 170 170 25 u.
0467 200 x 200 200 25 u.
0470 96 x 96 30 Oak 10 u.
0471 96 x 96 30 Beech 10 u.
0472 156 x 156 77 Oak 10 u.
0473 156 x 156 77 Beech 10 u.
0474 Ø 96 inner 27 Oak 10 u.
0475 Ø 96 inner 27 Beech 10 u.
0476 Ø 156 inner 60 Oak 10 u.
0477 Ø 156 inner 60 Beech 10 u.
METALLIC GRILLES
PRODUCT Code Dimension/mm Air movement /cm2
WOOD VENT GRILLES
STAINLESS STEEL GRILLES
PRODUCT Code Dimension/mm System
Grilles made of decorative wood in oak and beech.Available in both square and round.
Finished in high quality stainless steel with good design aesthetics.
ADVANTAGES:• Embodies an internal damper. • Easy cleaning• High quality finished. • Good design• Long life. • High strength and durable• Does not tarnish.
White lacquered
0402/0Front: (190 x 190 )
100 1 u.Inner: (Ø ext. 100)
0402/1Front: (190 x 190)
125 1 u.Inner: (Ø ext. 125)
PRODUCT Code Dimension/mm Air movement /cm2 Colour
KITS FOR EXTRACTION
20
Our KITS have been specially designed for the extraction of fumes on cooker hoods.
Are available on system 100-125 and 150, covering therefore, the flow needs from 300 m3/h to900 m3/h.
Maximum length 3 mts.
PRODUCT Code Description Air flow
KV-125 KIT SYSTEM 125 600-900 m3/h
Composition:• Flat channel 55 x 220 x 1000 mm 2• Rectangular flat connector 1• Mixed 90º elbow 1• Flat channel wall plate 1• Round louvred grille 1• Reducer cone Ø 120 to 125 mm 2• Flexible hose Ø 127 mm, L= 1 m 1• Screw and plugs 1
KV-150 KIT SYSTEM 150 > 900 m3/h
Composition:• Flat channel 90 x 180 x 1000 mm 2• Rectangular flat connector 1• Mixed 90º elbow 1• Flat channel wall plate 1• Round louvred grille 1• Reducer cone Ø 120 to 125 mm 2• Flexible hose Ø 150 mm, L= 1 m 1
• Screw and plugs 1
We can provide the kit with all of accessories that you need.
KV-100 KIT SYSTEM 100 300-600 m3/h
Composition:• Flat channel 55 x 110 x 1000 mm 2• Rectangular flat connector 1• Mixed 90º elbow 1• Flat channel wall plate 1• Round louvred grille 1• Reducer cone Ø 100 to 120 mm 2• Flexible hose Ø 102 mm, L= 1 m 1• Screw and plugs 1
We can provide the kit with all of accessories that you need.
21
FLEXIBLE HOSE
Flexible hose is made of PVC, encapsulating a spring steel helix wire.Flexible hose provides solutions for small installations or modifications. It is available in differentdiameters and lengths.
IDEAL FOR :• Kitchen stores, DIY, ironmongery and industrial suppliers, plumbing outlets
• WORKING TEMPERATURE: From 0° to 80° C• MAXIMUM PRESSURE: 100 m.c.a.• COLOUR: White• CLASSIFIED: Self-extinguish
APPLICATIONS
• EXTRACTION• TUMBLE DRYERS• VENTILATION• AIR INTAKES
Carton box size:600 x 400 x 400 mm
Pallet size:800 x 1200 x 2100 mm
PLEASE CONSULTFOR ANY SPECIALLENGTHS AND PACKAGING
• STEAM EVACUATION• BATHROOMS• SMALL INSTALLATIONS
Round flexible hoseCode Dimension/mm
0690/1 Ø 1 50 / L=1000 40 u.0690/3 Ø 1 50 / L=3000 20 u.0690/6 Ø 1 50 / L=6000 10 u.
0689/1,5 Ø 127 / L=1500 60 u.0689/3 Ø 127 / L=3000 30 u.0689/6 Ø 127 / L=6000 15 u.
0688/2 Ø 102 / L=2000 60 u.0688/3 Ø 102 / L=3000 45 u.0688/6 Ø 102 / L=6000 30 u.
Rectangular flexible hose
Code Dimension/mm Piezas
PR-800 75 x 150 / L=1000 4 u.
Rectangular flexible hose
Code Dimension/mm Piezas
PR-500 55 x 110 / L=1000 4 u.
SOUNDPROOF PIPE
22
Acoustic insulation for ducting systems for extraction of fumes
TECHNICAL SPECIFICATIONS:• 25 mm / 16 Kg. m3 fibreglass insulation.• Reinforced by an external aluminium foil / polyester 25 micras• The jacket prevents steam
CHARACTERISTICS:• Temperatures range: -30° C / + 140° C• M1 classified (flame retardant)
AL 120 Pipe of Ø 120 mm. L=560 mm cover L= 500 mm Insulating pipe Ø 120 mm
AL 125 Pipe of Ø 125 mm. L=560 mm cover L= 500 mm Insulating pipe Ø 125 mm
AL 150 Pipe of Ø 150 mm. L=560 mm cover L= 500 mm Insulating pipe Ø 150 mm
AL 600 Pipe of 60 x 120 mm. L=560 mm cover L= 500 mm Insulating pipe Ø Serie 600
AL 800 Pipe of 75 x 150 mm. L=560 mm cover L= 500 mm Insulating pipe Ø Serie 800
An effective seal to stop fire
ACTION• Protection acts between 180-200 ºC, the self-extinguish filter expands itself with a ratio
of 17 times i ts volume, causing a pressure upon t he tube of 10 bar.
• The expansion of the self-extinguish filter causes the pipe to break, by its oppression.The re fore , damaged area w il l be i solated from the remaining areas.
• Tested by B5476 Standards Parts 20 to 22, for 2 hours of fire protection.
COMPOSITIONThis self-extinguish and self-expanding material is wrapped by a thin plastic covering whichreacts to the heat from fire. It expands inwards stopping the spread of fire by rapidly providing100% fire proof seal.
INSTALATIONIt is fixed around the ducting with an adhesive tape.Protection must be placed betweenthe duct and the wall. In the event of fire the self-extinguish and self-expandingmaterial expands due to the temperature and pressure. As a result constricts the ductpreventing the fire spreading towards the tube.
Reference Description
FLAME RETARDANT SYSTEM
FW150 Protection against fire Ø 150 mm
FW110 x 55 Protection against fire 55 x 110 mm
FW150 x 75 Protection against fire 75 x 150 mm
FW220 x 55 Protection against fire 55 x 220 mm
FW100 Protection against fire Ø 100 mm
FW125 Protection against fire Ø 125 mm
Reference Composition Description
500 mm
560 mm
23
EXTRACTOR FANS
The extractor fans are essential elements for all the cooker hoods without extractor engine.
Their easy installation as well as their adaptability to the Gonal System 100 (Serie 500), pipes andaccessories makes the extractor fans indispensable for the air flow circuits lower than 300 m3/h
0580 • Tension: 220 Extractor with filter 4 u.
• Frequency: 50Hz
• Absorbed power: 120W
• Air flow: max 320 m3/h
• Loudness: 50 db
• Engine with thermal frequency
• Weight: 2,5 Kg
PRODUCT Code Technical specifications Description
0585 • Tension: 220 In-line tubular 4 u.
• Frequency: 50Hz extractor fan
• Absorbed power: 120W
• Air flow: max 320 m3/h
• Loudness: 50 db
• Engine with thermal frequency
• Weight: 2,5 Kg
0590 • Engine: 30W In-line tubular 2 u.
• Air flow: max 250 m3/h extractor fan
• Adaptable to pipes
• From 100 to 120 mm
A = 235 mmB = 125 mmC = 98 mmD = 118 mm
A
B
D C
150
24
Accessories Identifiable EAN label
DIMENSION• Height 184 x Width 117 x Depth 51 cm
Available in: SERIE 500 / SERIE 600 / SERIE 800
Combined: SERIE 500-800 / SERIE 600-800
DIY
27
An innovative point sales presentation for ventilationand extraction systems.
Less storage space required with these new accesories BOX PACK.
ADVANTAGES OF THE NEW PACKAGING BOX PACK
• Less number of pieces per box• Piece with barcode• Stronger packaging• Functional box for packaging and display• An image of the piece is show in the box• Maximum utilization of space• Assembly details
25
Usual presentation
… easily accesible
MULTIFORM WC
26
• ONE SOLUTION FOR ALL SITUATIONS
EXTENDIBLE SLEEVE WITH DIFFERENT LENGTHAdapts to all needs.No adhesive required, watertight, maintain required shape.
Round multiform pipe Ø 100 / Ø 1008111 15 u.
In PE 280 x 650
Round multiform pipe Ø 90 / Ø 1208220 16 u.
In PP 280 x 570
• Long or short• “S” shape• Elbow shape
90º
90º
90º
To solve your installation in 5 minutes
Description Dimensions/mm Code