Dual Feed Intelligent PDU...PDU I + III + II Amp : PDU I / III / II Power & kWh Outlet Measure Temp....

4
Dual Feed Intelligent PDU Single Phase - 230V / 208V / 110V >> Two PDUs by One Meter & Chassis >> 2.8" Color LCD Meter w/ Touchscreen >> Facilitate Rack Cabling >> Simplify Dual PDU Setup >> Reduce IP Address Cost >> Increase Management Efficiency Some data center racks are equipped with two PDUs. InfraPower W series Dual Feed PDU is designed to house two PDUs in a single chassis for simple installation. Users also benefit from the Red + Blue colored layout to distinguish the primary & secondary PDUs. > > > > > > 1 Chassis 2 PDUs Creatively, Austin Hughes develops 1 Meter 2 PDUs solution - InfraPower W series Dual Feed PDU. The sophisticated LCD touchscreen meter is integrated in a single chassis but for both primary and secondary PDUs. The meter not only allows local monitoring for 2 PDUs, but also supports up to 16 cascade levels. By the patent IP dongle, only one IP is required to access up to 32 PDUs in a single cascade group. > > > > > > 1 Meter 2 PDUs It becomes one of the cable management standard to separate power and data cables inside a rack. On the one hand, it minimizes the erratic data transfer as well as EMI. On the other hand, it distinguishes the power & data cabling. By InfraPower Dual Feed PDU, power & data cable separation is easily achieved. In addition, space-saving design and Red + Blue distinguishable layout contribute to a well-organized rack cabling. > > > > > > Facilitate Cable Management Why Dual Feed PDU ? PS-IP-DualFeed-SinglePhase-W-RM-Q420V1 Copyright 2020 Austin Hughes Electronics Ltd. All rights reserved. Design. Manufacturing. Global Services. www.austin-hughes.com Dual Feed Intelligent PDU Single Phase - 230V / 208V / 110V W PDU - Circuit Monitoring Wi PDU - Outlet & Circuit Monitoring WS PDU - Outlet Switching + Circuit Monitoring WSi PDU - Outlet Switching + Outlet & Circuit Monitoring Main 24.5 23.4 °C T2 T1 226.2 219.2 22.5 13.8 Volt Amp PDU I PDU II 65 37.5 45 22.3 15.9 3.48 3.49 15.8 31.7 6.97 C2 C1 8 7 6 5 4 3 2 1 65 37.5 45 22.3 15.9 3.48 3.49 15.8 31.7 6.97 C2 C1 8 7 6 5 4 3 2 1 PDU - I PDU - II 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1 C1 C1

Transcript of Dual Feed Intelligent PDU...PDU I + III + II Amp : PDU I / III / II Power & kWh Outlet Measure Temp....

Page 1: Dual Feed Intelligent PDU...PDU I + III + II Amp : PDU I / III / II Power & kWh Outlet Measure Temp. & Humid. Setup IP-DSW-2M/4M Door Sensor • With 2M or 4M cord • Cost efficient

Dual Feed Intelligent PDUSingle Phase - 230V / 208V / 110V

>> Two PDUs by One Meter & Chassis>> 2.8" Color LCD Meter w/ Touchscreen>> Facilitate Rack Cabling>> Simplify Dual PDU Setup>> Reduce IP Address Cost>> Increase Management Efficiency

Some data center racks are equipped with two PDUs.

InfraPower W series Dual Feed PDU is designed to house two PDUs in a single chassis for simple installation. Users also benefit from the Red + Blue colored layout to distinguish the primary & secondary PDUs.

> > > > > > 1 Chassis 2 PDUs

Creatively, Austin Hughes develops 1 Meter 2 PDUs solution - InfraPower W series Dual Feed PDU. The sophisticated LCD touchscreen meter is integrated in a single chassis but for both primary and secondary PDUs. The meter not only allows local monitoring for 2 PDUs, but also supports up to 16 cascade levels. By the patent IP dongle, only one IP is required to access up to 32 PDUs in a single cascade group.

> > > > > > 1 Meter 2 PDUs

It becomes one of the cable management standard to separate power and data cables inside a rack. On the one hand, it minimizes the erratic data transfer as well as EMI. On the other hand, it distinguishes the power & data cabling.

By InfraPower Dual Feed PDU, power & data cable separation is easily achieved. In addition, space-saving design and Red + Blue distinguishable layout contribute to a well-organized rack cabling.

> > > > > > Facilitate Cable Management

Why Dual Feed PDU ?

PS-IP-DualFeed-SinglePhase-W-RM-Q420V1Copyright 2020 Austin Hughes Electronics Ltd. All rights reserved.Design. Manufacturing. Global Services. www.austin-hughes.com

Dual Feed Intelligent PDUSingle Phase - 230V / 208V / 110V

W PDU - Circuit MonitoringWi PDU - Outlet & Circuit MonitoringWS PDU - Outlet Switching + Circuit MonitoringWSi PDU - Outlet Switching + Outlet & Circuit Monitoring

Main

24.523.4 °CT2T1

226.2

219.222.5

13.8

VoltAmpPDU IPDU II

6537.54522.3

15.9

3.483.49

15.831.7

6.97

C2C187654321

6537.54522.3

15.9

3.483.49

15.831.7

6.97

C2C187654321

PDU - I

PDU - II

8

8

7

7

6

6

5

5

4

4

3

3

2

2

1

1 C2

C2

C1

C1

Page 2: Dual Feed Intelligent PDU...PDU I + III + II Amp : PDU I / III / II Power & kWh Outlet Measure Temp. & Humid. Setup IP-DSW-2M/4M Door Sensor • With 2M or 4M cord • Cost efficient

One Side Orientation for Power CablingPower and data cables should be kept apart in order to vavoid interference. It is a typical practice to isolate power cabling to one side of the rack, whether it is for primary or secondary power connection. InfraPower Dual Feed PDU series offers an efficient, convenient & space saving solution - Primary & Secondary PDUs are integrated to one unit with dual power feed.

POWER DATA

PDU - I

A

B

The PDU can be cascaded up to 16 levels

For IP PDU access simply connect 1 x IP dongle

1 x IP Dongle allows access to 16 levels

LINK

TH 1

TH 2

5

5

4

4

PDUI

PDUII

Model Coverage

* Customization available on request

SwitchedMonitored

WSiWSWiW

Outlet Level Measurement Over IP

Circuit Amp - kWh Measurement

Billing Grade Meter Accuracy Within +/- 1%

32 / 16 Daisy Chained PDUs Supported on 1 IP

Free Management Software

Outlet Switch ON / OFF

1-Phase Intelligent Dual Feed PDU Series

2.0" Color LCD / 2.8" Color Touch LCD

SNMP Capability v2 / v3

Temp., Humidity, Smoke & Door Sensors

RCM (Residual Current Monitoring Module)

Door Mount PDU Panel w/ 4.3" Color LCD

Local Meter

Resettable Fuse / Hydraulic MCB

ELCR / Surge Protector / EMI Filter

1U / 2U Form Factors

Outlet Types :

Operating Temperature -5 to 60°C

Wifi Kit (Supports Max. 32 Daisy Chained PDUs)

Voltage 230V / 208V / 110V

IEC Individually Fused

US NEMA / C13 / C19

IEC Lockable

PS-IP-DualFeed-SinglePhase-W-RM-Q420V1Copyright 2020 Austin Hughes Electronics Ltd. All rights reserved.Design. Manufacturing. Global Services. www.austin-hughes.com

C13 C19

Lockable IEC Cable

• Connect to InfraPower lockable IEC outlets• Black / Grey / Red / Blue / Orange / Green

C14 - C13: 0.5M / 1M / 2M C20 - C19: 0.5M / 1M

IP Dongle

• Hot pluggable• Allows IP remote access• Up to 16 PDUs in daisy chain• SNMP capability v2 / v3

Patented Design

IPD-02-S

Dual Lan IP Dongle

• Allows IP remote access• Up to 32 PDUs in daisy chain• SNMP capability v2 / v3• Supports 10/100 & gigabit LAN ethernet

Patented Design

IPD-02-S

https://www.austin-hughes.com/support/productsheet/infrapower/PS-IP-IPD-03-S.pdfhttps://www.austin-hughes.com/support/productsheet/infrapower/PS-IP-IPD-03-S.pdfhttps://www.austin-hughes.com/support/productsheet/infrapower/PS-IP-IPD-03-S.pdfhttps://www.austin-hughes.com/support/productsheet/infrapower/PS-IP-IPD-03-S.pdfhttps://www.austin-hughes.com/support/productsheet/infrapower/PS-IP-IPD-03-S.pdfhttps://www.austin-hughes.com/support/productsheet/infrapower/PS-IP-IPD-03-S.pdfhttps://www.austin-hughes.com/support/productsheet/infrapower/PS-IP-IPD-03-S.pdfhttps://www.austin-hughes.com/support/productsheet/infrapower/PS-IP-IPD-03-S.pdfhttps://www.austin-hughes.com/support/productsheet/infrapower/PS-IP-IPD-03-S.pdfhttps://www.austin-hughes.com/support/productsheet/infrapower/PS-IP-IPD-03-S.pdfhttps://www.austin-hughes.com/support/productsheet/infrapower/PS-IP-IPD-03-S.pdf

C13 C19

Lockable IEC Outlet

• Low cost• Easy to lock• Secure

www.austin-hughes.com/support/productsheet/infrapower/PS-IP-LockableIEC.pdfwww.austin-hughes.com/support/productsheet/infrapower/PS-IP-LockableIEC.pdfwww.austin-hughes.com/support/productsheet/infrapower/PS-IP-LockableIEC.pdfwww.austin-hughes.com/support/productsheet/infrapower/PS-IP-LockableIEC.pdfwww.austin-hughes.com/support/productsheet/infrapower/PS-IP-LockableIEC.pdfwww.austin-hughes.com/support/productsheet/infrapower/PS-IP-LockableIEC.pdfwww.austin-hughes.com/support/productsheet/infrapower/PS-IP-LockableIEC.pdfwww.austin-hughes.com/support/productsheet/infrapower/PS-IP-LockableIEC.pdfwww.austin-hughes.com/support/productsheet/infrapower/PS-IP-LockableIEC.pdfwww.austin-hughes.com/support/productsheet/infrapower/PS-IP-LockableIEC.pdf

Page 3: Dual Feed Intelligent PDU...PDU I + III + II Amp : PDU I / III / II Power & kWh Outlet Measure Temp. & Humid. Setup IP-DSW-2M/4M Door Sensor • With 2M or 4M cord • Cost efficient

PS-IP-DualFeed-SinglePhase-W-RM-Q420V1Copyright 2020 Austin Hughes Electronics Ltd. All rights reserved.Design. Manufacturing. Global Services. www.austin-hughes.com

Ultra Density PDU ManagementW Series Dual Feed PDU combines highly efficient hardware connection with software remote management for Ultra High Density PDU Remote Management.

IP Dongle on the first PDU Level • For IP PDU access simply connect 1 x IP dongle • 1 x IP dongle allows access to 32 / 16 x PDU • Only 1 x IP for 32 / 16 x PDU access

• Daisy chain by Cat5 / 6 cable • Max. distance between 2 PDUs is 20M

• The PDUs can be cascaded up to 32 / 16 levels

Sophisticated W Meter with 2.8" Touchscreen LCDThe 2.8"" color LCD with touchscreen provides a sharp and highly visible display of kWh, kW, Power Factor, Volt, Amp, Temperature and Humidity.

Apart from monitoring, user can also set up the PDU daisy chain levels via the touchscreen LCD.

Amp & Volt :PDU I + III + II

Amp :PDU I / III / II Power & kWh Outlet Measure Temp. & Humid. Setup

IP-DSW-2M/4M

Door Sensor

• With 2M or 4M cord• Cost efficient integration into rack

Door Mount PDU Panel

• 4.3” color LCD touchscreen• Connect two PDU meters to display power, sensor status• Enhance information display• Plug & play

https://www.austin-hughes.com/support/productsheet/infrapower/PS-IP-IP-ED-01.pdfhttps://www.austin-hughes.com/support/productsheet/infrapower/PS-IP-IP-ED-01.pdfhttps://www.austin-hughes.com/support/productsheet/infrapower/PS-IP-IP-ED-01.pdfhttps://www.austin-hughes.com/support/productsheet/infrapower/PS-IP-IP-ED-01.pdfhttps://www.austin-hughes.com/support/productsheet/infrapower/PS-IP-IP-ED-01.pdfhttps://www.austin-hughes.com/support/productsheet/infrapower/PS-IP-IP-ED-01.pdfhttps://www.austin-hughes.com/support/productsheet/infrapower/PS-IP-IP-ED-01.pdfhttps://www.austin-hughes.com/support/productsheet/infrapower/PS-IP-IP-ED-01.pdfhttps://www.austin-hughes.com/support/productsheet/infrapower/PS-IP-IP-ED-01.pdfhttps://www.austin-hughes.com/support/productsheet/infrapower/PS-IP-IP-ED-01.pdfhttps://www.austin-hughes.com/support/productsheet/infrapower/PS-IP-IP-ED-01.pdf

• With 1M or 3M cord• When smoke alarm triggers,

sensor red LED lights on with beep sound continuously

Smoke Sensor

IP-S01-1M / 3M

• Plug & Play • With 2M or 4M cord• Magnetic base for easy affixing• Pair of sensors can be connected to an intelligent PDU meter

IG-TH-01-2M Temp. & Humid.

IG-T-01-2M Temp. only

Temp. & Humid. Sensor

Page 4: Dual Feed Intelligent PDU...PDU I + III + II Amp : PDU I / III / II Power & kWh Outlet Measure Temp. & Humid. Setup IP-DSW-2M/4M Door Sensor • With 2M or 4M cord • Cost efficient

1-Phase Intelligent Dual Feed PDU Series

NEMA 110V - 15A / 20A / 30A

10 x 2 DH20US-W

8 x 2 DH16US-W

12 DH24US-Wx 2

W PDU Circuit Monitoring

C13 C19

Outlet nos 208V - 20A / 30A230V - 16A / 20A / 32A

12 x 2 DH24C13-W

10 DH20C13-Wx 2

8 x 2 DH16C13-W

8 2 DH16C13 / 4C19-Wx 2

NEMA 110V - 15A / 20A / 30A

10 x 2 DH20US-WS

8 x 2 DH16US-WS

12 DH24US-WSx 2

WS PDU Outlet Switching + Circuit Monitoring

C13 C19

Outlet nos 208V - 20A / 30A230V - 16A / 20A / 32A

12 x 2 DH24C13-WS

10 DH20C13-WSx 2

8 x 2 DH16C13-WS

8 2 DH16C13 / 4C19-WSx 2

NEMA 110V - 15A / 20A / 30A

10 x 2 DH20US-Wi

8 x 2 DH16US-Wi

12 DH24US-Wix 2

C13 C19

Outlet nos 208V - 20A / 30A230V - 16A / 20A / 32A

12 x 2 DH24C13-Wi

10 DH20C13-Wix 2

8 x 2 DH16C13-Wi

8 2 DH16C13 / 4C19-Wix 2

NEMA 110V - 15A / 20A / 30A

10 x 2 DH20US-WSi

8 x 2 DH16US-WSi

12 DH24US-WSix 2

C13 C19

Outlet nos 208V - 20A / 30A230V - 16A / 20A / 32A

12 x 2 DH24C13-WSi

10 DH20C13-WSix 2

8 x 2 DH16C13-WSi

8 2 DH16C13 / 4C19-WSix 2

* Configuration & dimension may be modified without prior notice

Wi PDU Outlet & Circuit Monitoring

WSi PDU Outlet Switching + Outlet & Circuit Monitoring

L5-20P

Amp CordsetInlet

L5-30P

AWG length

30A 10 10 FT

20A 12 10 FT

15A 14 10 FT

5-30P

5-20P

5-15P

OutletNEMA

Amp CordsetInlet mm² length

32A 4 3 M

20A 2.5 3 M

C2060309 16A 1.5 3 M

BS1363 13A 1.5 3 M

Open end

60309

OutletC13 C19

Amp CordsetInlet

L6-20P

L6-30P

AWG length

30A 10 10 FT

20A 12 10 FT

208V PDU 110V PDU230V PDU

OutletC13 C19

Austin Hughes has an extensive distribution network, including the Americas, EMEA, ASEAN & APAC.

Contact your nearest sales office for details of local presentation.

Sales Inquiry

[email protected]

Technical Support

[email protected]

Distributed by:

Distributor by country on application

Available for :

- Custom PDU

- Colored IEC Outlet

- Lockable or Individually Fused IEC Outlet PDU

PS-IP-DualFeed-SinglePhase-W-RM-Q420V1Copyright 2020 Austin Hughes Electronics Ltd. All rights reserved.Design. Manufacturing. Global Services. www.austin-hughes.com