DT EET ProLEC FO Features - Raycap · ProLEC FO ProLEC FO lightning strike monitoring consists of a...

2
ProLEC FO ProLEC FO lightning strike monitoring consists of a sensor and optical electrical converter that communicates via fiber optic cable. The optical electrical converter sends data to the external device using a simple signaling protocol. The user equipment receives alarms transmitted by the optical electrical converter which helps to optimize operational efficiency and wind turbine maintenance procedures. Features Senses a direct lightning strike to a wind turbine’s lightning protection system (LPS) Detects lightning strikes above 2 kA amplitude Simple mounting Isolated fiber optic communications – 10 m optic cable included High voltage isolation Technical Data ProLEC FO Electrical Threshold Wind Current (8/20 µs) [I tc ] > 2 kA Maximum Withstand Current (10/350 µs) [I mcw ] 250 kA Threshold Detection Error +/- 200 A Power Supply Replaceable 3.6 V (Size D) battery Lifetime up to three years Communication Fiber optic Mechanical Temperature Range -40 °F to +131 °F [-40 °C to +55 °C] Environmental Ingress Protection (IP) Rating IP 65 Enclosure Material of Sensor GD-Al Si 12 (DIN 1725) Enclosure Dimensions 5.12" × 4.69" × 2.56" [130 × 119 × 65 mm] Weight Without Battery 1.52 lbs [690 g] With Battery 1.74 lbs [790 g] Standards Compliance & Certifications Standards EN 61326-1; EN 60068-2 Certification RoHS, CE Product Diagram [65] 2.56 [130] 5.12 [119] 4.69 [170] 6.69 [500] 19.6 www.raycap.com DATA SHEET

Transcript of DT EET ProLEC FO Features - Raycap · ProLEC FO ProLEC FO lightning strike monitoring consists of a...

ProLEC FO

ProLEC FO lightning strike monitoring consists of a sensor and optical electrical converter that communicates via fiber optic cable. The optical electrical converter sends

data to the external device using a simple signaling protocol.

The user equipment receives alarms transmitted by the optical electrical converter which helps to optimize operational efficiency and wind turbine maintenance procedures.

Features

• Senses a direct lightning strike to a wind turbine’s lightning protection system (LPS)• Detects lightning strikes above 2 kA amplitude• Simple mounting • Isolated fiber optic communications – 10 m optic cable included• High voltage isolation

Technical Data ProLEC FO

Electrical

Threshold Wind Current (8/20 µs) [Itc] > 2 kA

Maximum Withstand Current (10/350 µs) [Imcw] 250 kA

Threshold Detection Error +/- 200 A

Power Supply Replaceable 3.6 V (Size D) battery Lifetime up to three years

Communication Fiber optic

Mechanical

Temperature Range -40 °F to +131 °F [-40 °C to +55 °C]

Environmental Ingress Protection (IP) Rating IP 65

Enclosure Material of Sensor GD-Al Si 12 (DIN 1725)

Enclosure Dimensions 5.12" × 4.69" × 2.56" [130 × 119 × 65 mm]

Weight Without Battery 1.52 lbs [690 g]

With Battery 1.74 lbs [790 g]

Standards Compliance & Certifications

Standards EN 61326-1; EN 60068-2

Certification RoHS, CE

Product Diagram

65[65]2.56 [130]

5.12

[119

]4.

69

[170]6.69

[500]19.6

www.raycap.com

DATA SHEET

Typical Installation

ProLEC OEC

STATUS

INO

UT

ProLEC OEC

Fiber Optic Cable

Place of Installation

Technical Data ProLEC OEC

Electrical

Power Supply 5 VDC to 30 VDC

Communication Communication to sensor fiber optic

Communication to external device see user manual Appendix A

Mechanical

Temperature Range 32 °F to +131 °F [0 °C to +55 °C]

Environmental Ingress Protection (IP) Rating IP 20

Enclosure Material PA (polyamide): Extinguishing degree UL 94 V-0

Enclosure Dimensions 4.9" × 3.9" × 0.9" [124 × 99 × 22.6 mm]

Weight per Unit 0.24 lbs [110 g]

Standards Compliance & Certifications

Standards EN 61326-1

Certification RoHS, CE

Technical Data Fiber Optic Cable

Mechanical

Cable Type .039" [1 mm] diameter Standard POF grade

Attenuation 0.22 dB/m typical

Temperature Range -40 °F to 185 °F [-40 °C to +85 °C]

Construction Duplex plastic fiber, with black polyethylene jacket

Flame Rating Flame retardant: UL VW-1

Termination Unterminated

Maximum Operating Length 65.62' [20 m]

Order Code

ProLEC FO Order Code 130 533