DT Case Study
-
Upload
tayyabijaz87 -
Category
Documents
-
view
222 -
download
0
Transcript of DT Case Study
_______DT ISSUES CASE STUDY______
1
Case Study
DT Analysis
Prepared By:
Zeeshan Asghar
RF Consultant
Aircom International
Huawei/Warid Project
_______DT ISSUES CASE STUDY______
2
Table of contents
Summary
1- C/I issues……………………………………………………………
2- Rx Quality Issues-----------------------------------------------------------
3- Rx Level Issues--------------------------------------------------------------
4- Cell Identification Issues---------------------------------------------------
_______DT ISSUES CASE STUDY______
3
Summary
Here we are highlighting few cases, which normally occur while doing the DT. It will
give the idea to DT engineer regarding to the issues on the site while doing the DT.
There are many other issues which normally occur, and which we have to justify, but all
such cases depends upon case by case, for example, Speech Codec issues, SQI issues,
UL/OL issues.
If any other issues comes, which are other than those which are discuss below, please
kindly let me know so I can provide you the reason to justify them.
C/I ISSUES
Case # 1
_______DT ISSUES CASE STUDY______
4
Case # 2
Note: C/I on BCCH, was not decoded on some intervals, and that’s the reason it show “Blank” or “N/A” values, and In MapInfo or Tems when you plot it, they consider Blank or N/A as zero. That’s why we can see the samples of 0-9 over the snapshot, but if we see the Graph Chart we can find that there are no samples in between range 0-9.
_______DT ISSUES CASE STUDY______
5
Case # 3
The C/I are bad in the highlighted region, because 58852 BCCH is 2, and it was a MA list clash with the hopping frequency “1”.
_______DT ISSUES CASE STUDY______
9
CASE # 7
Note: C/I is bad in the region of 3rd cell, because the 3rd cell BCCH is 16, and whenever the call went over 900, there was a MA List clash between adjacent frequency i.e. 17.
_______DT ISSUES CASE STUDY______
10
RX QUALITY ISSUES
CASE # 1
Note: Mark A, B, C RxQual is bad, because the cell 58672, 45592 and 58662 have the adjacent frequencies. All the 3 cells area serving in the open area, that’s why due to adjacent frequency clash the quality, C/I and SQI is bad.
_______DT ISSUES CASE STUDY______
17
CASE # 2
Low RxLev because
there’s no Dominant
server. Call keep shifting
between 900 and 1800
Hopping.
_______DT ISSUES CASE STUDY______
21
Cell Id Issues
CASE # 1
Note: The handover between 58941 and 57661 wasn’t occurred , because 5766 is an old site and I
think its CGI are swap, because in the serving area of 57661, 57663 is serving , in the area of 57662 ,
57661 is serving and in the area of 57663, 57662 is serving. That’s the reason, while moving from cell
58941 it first handover to 58943 and then it handover to 57662 as 57662 is not in the neighbour list of
58941.
_______DT ISSUES CASE STUDY______
22
CASE # 2
Note: There were 2 drives in between 59302 and 59311, when we went from 59302
towards 59311, it was dominant and then it handover to 59311. And while coming towards 59302 from 59311, the cell 59311 was dominant and then it handover with good levels to 59302. The samples are overlapped that’s why it’s not so clear to see the samples of 59302.