Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0...

20
Dryvit’s HDCI TM Program High Durability Continuous Insulation

Transcript of Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0...

Page 1: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy

Dryvit’s HDCITM ProgramHigh Durability Continuous Insulation

Page 2: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy

Overview

1. Over 30 years in Canada2. Dryvit is sustainable3. Dryvit’s HDCITM Program

High Durability Continuous Insulation

4. Durability proven with CCMC/ULC-S7165. Also fire resistance – testing & listing at ITS6. Most thermally efficient to meet energy code 7. Summary

� In your next specification, here’s what to include…� Good performance hinges on…

Chateau Lake Louise

Page 3: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy

Dryvit is Sustainable…Embodied Energy

National Institute of Standards & Technology – BEES v4.0

Gre

enes

t

Page 4: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy

Dryvit is Sustainable…CO2 Emissions

National Institute of Standards & Technology – BEES v4.0

Gre

enes

t

Page 5: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy

Dryvit’s HDCITM Program…High Durability Continuous Insulation

� 20 Year warranty including substrate moisture protection

� Panzer® 20 & Corner� Industry 1st: impact

resistance warranty� Can be specified for

all Outsulation®

� Outsulation Plus� Outsulation MD� Outsulation PD

Page 6: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy

Dryvit is…Impact Resistant

4.3 6.0 12.0 15.0+4.3 20.5+4.3(ounces/yd 2)

Inch-pounds

Panzer®

Page 7: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy

Impact Resistance Guide

MESH TYPE MESH WEIGHT RECOMMENDED LOCATIONS

Standard Mesh 4.3 oz/yd 2 Walls in general service (not readily accessible to pedestrians & maintenance)

Standard Plus 6.0 oz/yd 2 Walls in general service and areas with infrequent access to maintenance

Intermediate 12.0 oz/yd 2 Balcony wall areas, or walls with medium maintenance access

Panzer 15 + Standard

Mesh

15.0 oz/yd 2

+ 4.3 oz/yd2Grade level (within 4 - 8 ft.) with light to medium to heavy pedestrian traffic

Panzer 20 + Standard

Mesh

20.5 oz/yd 2

+ 4.3 oz/yd2Heavy duty reinforcing for walls with medium to heavy pedestrian traffic

Panzer 20 + Standard

MeshHDCITM Panzer Corner & Panzer 20 for

100% of walls.

Page 8: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy

New Construction

Page 9: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy

Panelization

Page 10: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy

Panelization

Page 11: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy

OVERCladding

Page 12: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy

RECladding

Page 13: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy

Dryvit has…CCMC Approval

� Registered since 1998…

� Basis for ULC-S716 Standards

� Adopted by NBC and OBC in 2015

Page 14: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy

Dryvit has…Fire Testing

Page 15: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy

Outsulation System(Plus/MD/PD)

Nominal EIFS R-Value Estimated Assembly Value

2” EPS 7.6 9.93” EPS 11.4 13.64” EPS 15.2 17.25” EPS 19.0 20.96” EPS 22.8 24.6

Nominal 3-5/8” Steel Stud Wall – ½” Glass Mat Faced S heathing, Interior ½” Drywall, No Stud Cavity Insulation

Dryvit is…The Most Thermally Efficient

Page 16: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy

SummaryDryvit Outsulation ®

�Smallest carbon footprint…�+30 years history in Canada �CCMC registered since 1998�Fire testing for noncombustible

construction�Aesthetic versatility unlike no other�HDCITM = 20 Year Warranty +

Impact Resistance

Page 17: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy

HDCITM in your next specification…

� After specifying Outsulation® Plus, MD, or PD, specify Dryvit’s HDCITM , as follows:� “Dryvit HDCI with Panzer 20 and Panzer Corner

are required for 100% of the wall areas.”� “System manufacturer shall provide a 20 year

warranty, including provisions to repair impact damage through the EIFS lamina, and moisture protection of the substrate.”

EASY!

Page 18: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy

Good Service Life Hinges on…

� Critical details (design):� Panelization = engineered cladding� High impact resistance = HDCITM

� Stain resistance – detail for rain deflection

� Quality control (construction):� Dryvit requires “Contractor Agreements ”

signatory to Dryvit’s specs & details� Dryvit tech -support during construction

� Maintenance (what & when)� DryvitCARE & maintenance guide

Page 19: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy

Design Flexibility

Page 20: Dryvit’s HDCI TM Program High Durability Continuous Insulation...Panzer 15 + Standard Mesh 15.0 oz/yd 2 + 4.3 oz/yd 2 Grade level (within 4 - 8 ft.) with light to medium to heavy

Dryvit’s HDCITM ProgramHigh Durability Continuous Insulation

1-800-263-3308www.dryvit.ca