NORTHERN LIGHTS
LEFT SIDE (SERVICE SIDE)FRONTREAR
BOTTOM
PLAN
THE DIMENSIONS ON THIS DRAWING ARE SUBJECT TO CHANGE.PLEASE CONTACT NORTHERN LIGHTS INC. TO BE SURE YOUHAVE THE MOST CURRENT REVISION.
NOTE: GENSET WEIGHT INCLUDES COOLANT & OIL.
OPTIONAL COMPOUND MOUNTS
DRY EXHAUST ELBOW DETAILSCALE 1:4
D
C
B
AA
B
C
D
12345678
8 7 6 5 4 3 2 1
E
F
E
F
REV
D-50
53D
SHEET 1 OF 1
10/17/17
10/19/17TAH
MG
UNLESS OTHERWISE SPECIFIED:
SCALE: 1:10 WEIGHT:
REVDWG. NO.
DSIZE
TITLE:
NAME DATE
COMMENTS:
Q.A.
MFG APPR.
ENG APPR.
CHECKED
DRAWN
FINISH
MATERIAL
INTERPRET GEOMETRICTOLERANCING PER: ASME Y14.5M
DIMENSIONS ARE IN MILLIMETERSTOLERANCES:ANGULAR: MACH± 0.5° BEND ± 1.0°NO DECIMALS: ± 3ONE DECIMAL: ± 1
PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFNORTHERN LIGHTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF NORTHERN LIGHTS IS PROHIBITED.
THIRD ANGLE PROJECTION
4420 14th AVE. N.W.Seattle, WA 98107(206) 789-3880www. northern-lights.com
D-5053
INSTALLATION DIMENSIONSM944T3F KEEL COOLED
MODEL RATING FREQUENCY PHASEM944T3F.2 40 kW 60 Hz 3M944T3F.4 38 kW 60 Hz 1
ITEM WEIGHT C.G.X Y Z
GENSET 737 kg [1625 LBS.] 293 282 477GENSET W/PTO 779 kg [1717 LBS.] 293 278 448
GENSET W/HD PTO 798 kg [1758 LBS.] 293 277 433
0
124
241
388
179
209
0
282
533622
WATER HEATER RETURNPORT 3/8"NPT
WATER HEATER SUPPLYPORT 3/8"NPT
CRANKCASE OIL DIPSTICKCRANKCASE OIL FILTER
FUEL RETURN1/4"NPTFUEL SUPPLY
1/4"NPT
COOLANT OUTLETØ 1.50" [38] H.B.
055
"Y"
0
152
203"X"
387
610
842
FUEL FILTEREXPANSION TANK
POWER TAKE-OFF PUMPMOUNTING FACE (OPTIONAL)
"B" SPLINE 13T 16/32 D.P.2 AND 4 BOLT FLANGE
COMPOUND MOUNTOPTIONAL
OIL DRAIN3/8"NPT
COOLANT INLETØ 1.63" [41] H.B.
0"Z"
808
1213
1221
312
376
W/P
TO O
PTIO
N
042
127
282
779793COOLANT FILL
VALVE COVER OIL FILL
STARTER
pDP FILTER
0160
1221
0
243293
673
64
1704
TURBO AIR INLET FILTER
808 312
610
64
305
4X Ø 16 THRU
1524
737
RIGHT SIDE
0
127
789
02764 293
305
610
557
636
673
DRY EXHAUST ELBOW3"-150LB ANSI STD BOLTING
SEE DETAIL
72
144 TYP8X SLOT 14 X 18
Ø19
17.
50
Ø 152 6.00 B.C.
4X Ø 19 0.75 THRU Ø63
2.47