• Dry Cooling Towers (Air Cooled Condenser):
o A-Type Dry Cooling Systems
o V-type Dry Cooling Systems
• Wet cooling systems:
o Natural draft cooling towers
o Natural draft and Circular mechanical draft cooling towers
o Hybrid Cooling Towers (combination of wet cooling and dry cooling
o Cell-Type Cooling Towers
Supplied Products
![Page 3: Dry Cooling Towers (Air Cooled Condenser) - eps-e.rueps-e.ru/img/GEA-eng.pdf · •Dry Cooling Towers (Air Cooled Condenser): o A-Type Dry Cooling Systems o V-type Dry Cooling Systems](https://reader031.fdocuments.us/reader031/viewer/2022020204/5aacc8a27f8b9a693f8d8150/html5/thumbnails/3.jpg)
A-Type Dry Cooling Systems
Direct dry cooling
In direct dry cooling, steam obtained from station or from any other technical processes
condensates in air-cooled condenser.
![Page 4: Dry Cooling Towers (Air Cooled Condenser) - eps-e.rueps-e.ru/img/GEA-eng.pdf · •Dry Cooling Towers (Air Cooled Condenser): o A-Type Dry Cooling Systems o V-type Dry Cooling Systems](https://reader031.fdocuments.us/reader031/viewer/2022020204/5aacc8a27f8b9a693f8d8150/html5/thumbnails/4.jpg)
A-Type Dry Cooling Systems
Steam Duct
Collector Cooling Air
Fan
Heat Exchanger
![Page 5: Dry Cooling Towers (Air Cooled Condenser) - eps-e.rueps-e.ru/img/GEA-eng.pdf · •Dry Cooling Towers (Air Cooled Condenser): o A-Type Dry Cooling Systems o V-type Dry Cooling Systems](https://reader031.fdocuments.us/reader031/viewer/2022020204/5aacc8a27f8b9a693f8d8150/html5/thumbnails/5.jpg)
V-type Dry Cooling Systems
Functional principle of V-type Dry Cooling Systems
![Page 6: Dry Cooling Towers (Air Cooled Condenser) - eps-e.rueps-e.ru/img/GEA-eng.pdf · •Dry Cooling Towers (Air Cooled Condenser): o A-Type Dry Cooling Systems o V-type Dry Cooling Systems](https://reader031.fdocuments.us/reader031/viewer/2022020204/5aacc8a27f8b9a693f8d8150/html5/thumbnails/6.jpg)
• Natural draft cooling towers
Wet cooling systems Classification of cooling towers
• Circular mechanical draft cooling towers
• Hybrid Cooling Towers
• Cell-Type Cooling Towers
![Page 7: Dry Cooling Towers (Air Cooled Condenser) - eps-e.rueps-e.ru/img/GEA-eng.pdf · •Dry Cooling Towers (Air Cooled Condenser): o A-Type Dry Cooling Systems o V-type Dry Cooling Systems](https://reader031.fdocuments.us/reader031/viewer/2022020204/5aacc8a27f8b9a693f8d8150/html5/thumbnails/7.jpg)
- operate on the stack effect which causes
the hot air in the tower to rise (natural
draft).
- Wet natural draft cooling towers are used
mainly for electrical energy industry, but
can be used for other industrial objects.
- Such towers allow the cooling of high
water volumes and are designed both
from concrete and metal structures.
Natural draft cooling towers
Key features
![Page 8: Dry Cooling Towers (Air Cooled Condenser) - eps-e.rueps-e.ru/img/GEA-eng.pdf · •Dry Cooling Towers (Air Cooled Condenser): o A-Type Dry Cooling Systems o V-type Dry Cooling Systems](https://reader031.fdocuments.us/reader031/viewer/2022020204/5aacc8a27f8b9a693f8d8150/html5/thumbnails/8.jpg)
• Advantages:
o No energy consumption for fans operation
o No recirculation
o Low costs of maintenance and spare parts
o Low thermal energy waste
• Disadvantages:
o Higher investment costs
o Large overall dimensions that could cause
difficulties with area aesthetics and
requirement of large areas for tower
installation
Natural draft cooling towers
![Page 9: Dry Cooling Towers (Air Cooled Condenser) - eps-e.rueps-e.ru/img/GEA-eng.pdf · •Dry Cooling Towers (Air Cooled Condenser): o A-Type Dry Cooling Systems o V-type Dry Cooling Systems](https://reader031.fdocuments.us/reader031/viewer/2022020204/5aacc8a27f8b9a693f8d8150/html5/thumbnails/9.jpg)
- natural draft cooling towers equipped with
fans.
- The fans are installed at the air inlet for
forced-draft air movement or on a deck
above the fills to induce air flow.
- Increased air velocity, caused by the
installation of fans, allows a compact
design.
- Circular mechanical draft cooling towers
are used both for power station and for
process cooling applications.
Circular mechanical draft cooling towers
Key features
![Page 10: Dry Cooling Towers (Air Cooled Condenser) - eps-e.rueps-e.ru/img/GEA-eng.pdf · •Dry Cooling Towers (Air Cooled Condenser): o A-Type Dry Cooling Systems o V-type Dry Cooling Systems](https://reader031.fdocuments.us/reader031/viewer/2022020204/5aacc8a27f8b9a693f8d8150/html5/thumbnails/10.jpg)
• Advantages:
o Investment costs are lower in comparison with
natural draft cooling towers
o No recirculation
o Low energy consumption for fans operation
due to stack effect
• Disadvantages:
o Energy consumption for fans operation
o Still rather high investment costs
o Costs of technical maintenance and spare parts
Circular mechanical draft cooling towers
Key features
![Page 11: Dry Cooling Towers (Air Cooled Condenser) - eps-e.rueps-e.ru/img/GEA-eng.pdf · •Dry Cooling Towers (Air Cooled Condenser): o A-Type Dry Cooling Systems o V-type Dry Cooling Systems](https://reader031.fdocuments.us/reader031/viewer/2022020204/5aacc8a27f8b9a693f8d8150/html5/thumbnails/11.jpg)
• No visible plumes emitted from the
cooling tower
• Многосекционного или кругового
типа
• Multi-cell or circle type
• Mechanical draft
• Nowadays are widely used for power
stations and for many industrial fields
Hybrid Cooling Towers (combination of wet cooling and dry cooling)
Key features
![Page 12: Dry Cooling Towers (Air Cooled Condenser) - eps-e.rueps-e.ru/img/GEA-eng.pdf · •Dry Cooling Towers (Air Cooled Condenser): o A-Type Dry Cooling Systems o V-type Dry Cooling Systems](https://reader031.fdocuments.us/reader031/viewer/2022020204/5aacc8a27f8b9a693f8d8150/html5/thumbnails/12.jpg)
• Advantages
o Reducing of plume size
• Disadvantages
o Higher investment costs comparably to
standard cell-type cooling towers
o High risk of recirculation
o High energy consumption
o Costs for service maintenance and spare
parts
Hybrid Cooling Towers (combination of wet cooling and dry cooling)
![Page 13: Dry Cooling Towers (Air Cooled Condenser) - eps-e.rueps-e.ru/img/GEA-eng.pdf · •Dry Cooling Towers (Air Cooled Condenser): o A-Type Dry Cooling Systems o V-type Dry Cooling Systems](https://reader031.fdocuments.us/reader031/viewer/2022020204/5aacc8a27f8b9a693f8d8150/html5/thumbnails/13.jpg)
• The multi-cell design flexibility renders
possible to fit different environmental air
temperatures
• Forced air circulation
• Compact structure
• Maximum usage of factory-built structural
components
• There are structures for any cooling water
flow and any heat capacity
• These cooling towers type is widely used
for power plants and for many branches of
industry
Cell-Type Cooling Towers
Key features
![Page 14: Dry Cooling Towers (Air Cooled Condenser) - eps-e.rueps-e.ru/img/GEA-eng.pdf · •Dry Cooling Towers (Air Cooled Condenser): o A-Type Dry Cooling Systems o V-type Dry Cooling Systems](https://reader031.fdocuments.us/reader031/viewer/2022020204/5aacc8a27f8b9a693f8d8150/html5/thumbnails/14.jpg)
• Advantages:
o Low investment costs
o The multi-cell design renders possible to fit
any cooling load and air temperature
o Maximum usage of factory-built structures
permits to reduce building period
• Disadvantages:
o Energy costs for fans operation
o Technical service and spare parts costs
o Possibility of recirculation
o Possible negative influence of standing by
cooling towers
Cell-Type Cooling Towers
![Page 15: Dry Cooling Towers (Air Cooled Condenser) - eps-e.rueps-e.ru/img/GEA-eng.pdf · •Dry Cooling Towers (Air Cooled Condenser): o A-Type Dry Cooling Systems o V-type Dry Cooling Systems](https://reader031.fdocuments.us/reader031/viewer/2022020204/5aacc8a27f8b9a693f8d8150/html5/thumbnails/15.jpg)
Closed Joint-Stock Company "Energopromservice-Engineering"
Post address:
11, Komsomolsky Prospect, Moscow, Russia
119146Tel./fax:
+7(495) 780-57-86 - multichannel
E-mail: [email protected]
Контакты