Drwg.No.: Date: C-i-HeartFelt-Linear-BIM 01-09-2020 ......C-i-HeartFelt-Linear-BIM 1 : 15 03...

3
Subject: Date: Drwg.No.: Size: Scale: Rev: C-i-HeartFelt-Linear-BIM 01 01-09-2020 _Standard Product Overview - Perspective BIM_Revit Standard_LOG 200 A3 A

Transcript of Drwg.No.: Date: C-i-HeartFelt-Linear-BIM 01-09-2020 ......C-i-HeartFelt-Linear-BIM 1 : 15 03...

Page 1: Drwg.No.: Date: C-i-HeartFelt-Linear-BIM 01-09-2020 ......C-i-HeartFelt-Linear-BIM 1 : 15 03 01-06-2020 _Application BIM_Revit Standard_LOG 200 A3 A NOTE: For correct panel and carrier

Subject:

Date:Drwg.No.:

Size:

Scale:

Rev:

C-i-HeartFelt-Linear-BIM01

01-09-2020

_Standard ProductOverview - Perspective

BIM_Revit Standard_LOG 200

A3 A

Page 2: Drwg.No.: Date: C-i-HeartFelt-Linear-BIM 01-09-2020 ......C-i-HeartFelt-Linear-BIM 1 : 15 03 01-06-2020 _Application BIM_Revit Standard_LOG 200 A3 A NOTE: For correct panel and carrier

Subject:

Date:Drwg.No.:

Size:

Scale:

Rev:

1 : 10C-i-HeartFelt-Linear-BIM02

01-09-2020

_Standard ProductOverview

BIM_Revit Standard_LOG 200

A3 A

Page 3: Drwg.No.: Date: C-i-HeartFelt-Linear-BIM 01-09-2020 ......C-i-HeartFelt-Linear-BIM 1 : 15 03 01-06-2020 _Application BIM_Revit Standard_LOG 200 A3 A NOTE: For correct panel and carrier

APPLICATION OF HEARTFELT CEILING M100

start/end panel150

max. panel span 900mm (40HL105)max. panel span 1200mm (40HL55-80, 40HR64)

max. panel span 900mm (40HL105)max. panel span 1200mm (40HL55-80, 40HR64)

start/end panel150

Panel Length = min 1000mm - max 6000mm Panel Length = min 1000mm - max 6000mm

HeartFelt Linear Splice 40HL55

HeartFelt Linear 40HL5540HL55_7596 Light Grey

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

100

HeartFelt AL CarrierM100_Transparent Coated

max 3

00ma

x 150

0ma

x 300

Carrie

r Spa

nma

x 150

0ma

x 300

Luxalon CarrierSplice_Transparent Coated

HeartFelt Linear 40HL5540HL55_7576 Light Brown

/Black

/Black

* only

on

1 sid

e of

carri

er sp

lice

(afte

r eve

ry 2n

d han

ger)

distan

ce be

twee

n Stab

ilisati

on P

rofile

s = m

ax 30

00mm

Luxalon Suspension AdjustmentSpring

Carri

er Le

ngth

= max

5000

mmCa

rrier

Leng

th = m

ax 50

00mm

Subject:

Date:Drwg.No.:

Size:

Scale:

Rev:

1 : 15C-i-HeartFelt-Linear-BIM03

01-06-2020

_Application

BIM_Revit Standard_LOG 200

A3 A

NOTE: For correct panel and carrier spans always check the installation brochure of HeartFelt Linear Ceiling!TOP VIEW

PERSPECTIVE VIEW