Page 1: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

DRIVEN BY SAFETY. FOCUSED ON QUALITY.

Page 2: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

1-800-MEDLINE | www.medline.com2

SAFETY. SELECTION. SUPPORT.

With Medline electrosurgical

products, you have it all: unique safety

features, a complete selection of high-

quality products and support that’s

second to none.

Throughout our offering of electrosurgical supplies,

you’ll fi nd unique features that provide safety for both

patients and clinicians.

The Universal Electrosurgical Grounding Pad is made

with the highest-quality 3M adhesives. The pad features a

proprietary Green Safety Ring with advanced technology

that reduces corner-and-edge effect and makes

placement much easier. Because of this technology, the

pad has a 33% smaller footprint and it can be orientated

in any direction.

Our complete selection of electrosurgical pencils

includes push-button, rocker-switch and foot-switch

confi gurations. And we carry a full line of stainless

steel and PTFE tips, including LLETZ Tungsten Loops,

laparoscopic tips and microsurgical Tungsten needles.

Bovie® Medical brand generators provide a consistent

clinical effect with the utmost safety, convenience and

fl exibility. Medline is proud to be a US distributor of

Bovie electrosurgical generators.

Medline not only warranties our own electrosurgical

generators but those of our competitors as well, at no

charge, provided they’re less than eight years old. We

offer the longest service plan in the industry, with

up to eight years of coverage. All our products are fully

guaranteed, and we indemnify our customers against any

and all losses.*

*Conditions apply. See page 43 for our Guarantee and Indemnifi cation policies.

Page 3: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

padspencils

electrodesaccessories

forcepsgenerators

support1-800-MEDLINE | www.medline.com 3

4 . . . . . . . . GROUNDING PADS

8 . . . . . . . .Universal Electrosurgical Pad with Safety Ring (9100 Series) 9 . . . . . . . . .Electrosurgical Grounding Pads (1100 Series)10 . . . . . . . . .Reusable Cables (21100 Series)

12 . . . . . . . . .ELECTROSURGICAL PENCILS

14 . . . . . . . . .Vega Series15 . . . . . . . . .Vega Series with Blue Silk® PTFE Non-Stick Coated Tips16 . . . . . . . . .Cygnus Series

17. . . . . . . . . ELECTROSURGICAL ACTIVE ELECTRODES (TIPS)

18 . . . . . . . . .Blue Silk® PTFE Non-Stick Coated Electrodes 20 . . . . . . . . .Stainless Steel Electrodes21 . . . . . . . . .Lletz Tungsten Loop Electrodes22 . . . . . . . . .Arthroscopic Electrodes22 . . . . . . . . .Microsurgical Tungsten Needles23. . . . . . . . . Laparoscopic Electrodes

24. . . . . . . . . ACCESSORIES

25 . . . . . . . . .Electrosurgical Tip Cleaner25 . . . . . . . . .Bipolar Cord25 . . . . . . . . .Electrosurgical Safety Holster

26. . . . . . . . . REUSABLE BIPOLAR FORCEPS

27 . . . . . . . . .Straight Bipolar Forceps 30 . . . . . . . . .Bayonet Bipolar Forceps 33 . . . . . . . . .Reusable Accessories

34. . . . . . . . . B OVIE® GENERATORS AND SMOKE EVACUATORS

36 . . . . . . . . .Bovie Icon GP Electrosurgical Generator38 . . . . . . . . .Bovie IDS Electrosurgical Generators40 . . . . . . . . .Bovie Smoke Evacuator41 . . . . . . . . .Smoke Evacuator Accessories

42. . . . . . . . . SERVICE AND SUPPORT

44. . . . . . . . . INDEX

TABLE OF CONTENTS

cross referencepads

supportoss reference

supportsupport

crocc

padspencils

electrodesaccessories

forcepsgenerators

support

Page 4: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

1-800-MEDLINE | www.medline.com4

The Medline Universal Electrosurgical

Grounding Pad 9100 Series (manufactured

by 3MTM) is a breakthrough in electrosurgical pad

technology. This pad is smaller in size – a mere 15

square inches – so it’s very easy to place, and it

meets the same thermal performance standards

as traditional pads with a 33% larger conductive

surface area. This Safety Ring technology is only

available on Medline universal grounding pads.

GROUNDING PADS

5 … UNIVERSAL ELECTROSURGICAL PAD

WITH SAFETY RING (9100 SERIES)

8 … ELECTROSURGICAL GROUNDING PADS

(1100 SERIES)

9 … REUSABLE CABLES (21100 SERIES)

Page 5: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

padspencils

electrodesaccessories

forcepsgenerators

support1-800-MEDLINE | www.medline.com 5

Universal Electrosurgical Pad with Safety Ring (9100 Series)

padsp

ads

THE SOLUTION TO AN OLD PROBLEM

The tendency for electrosurgical current and heat to cluster at the leading edge of a non-capacitive pad has been a long-standing, industry-wide design concern. Because of this clustering (known as “corner and edge effect"), safety considerations have dictated that pads should be placed with the long edge perpendicular to the surgical site.

Uniform dispersion of current

Current clusters at leading edge and corners

Universal Electrosurgical Pad with Safety Ring

The revolutionary green Safety Ring provides Medline’s pad with greater effi ciency and reduced corner and edge effect, thereby allowing for smaller size and universal orientation.

PROPRIETARY SAFETY RING ALLOWS FOR UNIVERSAL ORIENTATION AND CONVENIENCE

Traditional Design

Page 6: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

1-800-MEDLINE | www.medline.com6 1-1 80800-0 MEMEDLDLININEE || wwwwww.memedldlininee.cocomm66

Medline’s Universal Electrosurgical Pad, with our revolutionary, patented Green Safety Ring.

• Same Performance in a Smaller SizeThe Medline Universal Electrosurgical Pad meets IEC criteria for temperature rise (ANSI/AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads that are 33% larger.

• More Evenly Distributed Current With the Medline pad, current is reduced at the corners and the leading edge. This more uniform dispersion reduces “corner and edge effect,” while meeting the same thermal performance standards as pads with a 33% larger conductive surface area.

• Cost-EffectiveStandardizing with the Medline Universal Pad can help you eliminate SKUs. Infant pads may no longer be necessary as the Medline pads have no minimum age or weight requirement, as long as the pad makes full contact with the patient – without overlap – at a suitable placement site.

• Three-Year Shelf LifeThe Medline pad’s long shelf life helps improve inventory management effi ciency.

• Latex Free No natural rubber latex or dry natural rubber is used in 9100 Series Electrosurgical Pads or their packaging.

• Broad CompatibilityThe Medline Universal Pad with Safety Ring is compatible with all electrosurgical generators (ESUs) used in surgical procedures, as defi ned by the ANSI/AAMI Standard HF18:2001, Electrosurgical Devices.

Stress Flaps The tab end of the plate is securely held onto the patient with stress fl aps, minimizing the chance of dislodging if the cable or cord is inadvertently pulled.

Easy to Place

Smaller size allows the pad to be oriented in any direction at a suitable placement site.

GROUNDING PADS

Page 7: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

padspencils

electrodesaccessories

forcepsgenerators

support1-800-MEDLINE | www.medline.com 7

Transthermal Backing Permits Heat to Escape Faster.

Older grounding pads use a foam backing material, which locks in heat. Medline’s Universal Pads use a transthermal backing, similar to surgical drape material, which lets heat escape 25% faster than foam and reduces the risk of unsafe temperature rise.

Fluid-Resistant Backing

Similar to surgical drapes, the Medline pads feature a nonwoven backing with a thick (3 mil) layer of polyethylene, forming a waterproof, fl uid-resistant moisture barrier.

Non-Conductive Isolation Border

To help seal out unwanted fl uids, the conductive adhesive gel is surrounded by a non-conductive isolation border. The pad’s border adhesive is similar in properties to 3M’s popular Micropore™ tape.

Helps Reduce Chance of Skin Stripping

For patients with fragile skin, our non-aggressive border adhesive reduces the possibility of skin stripping.

Excellent Pad-To-Skin Contact

Water-based hydrophilic conductive adhesive fl ows uniformly into skin crevices, providing exceptional pad-to-skin contact.

padsp

ads

R-Value* for Backing

Blue Foam

Backing

Universal PadTransthermal Backing *R-Value is a material’s resistance to heat transmission.

0.9

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0

Page 8: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

1-800-MEDLINE | www.medline.com8

GROUNDING PADS

Electrosurgical Grounding Pads (1100 Series)Low-impedance connection with minimal skin irritation and skin trauma. The 1100 Series grounding pads have a soft, gel-like conductive adhesive surrounded by an isolation border on a white foam backing. Item nos.1149, 1149C-LP, 1179 and 1180 have a conductor area of approximately 20 square inches. Our Small Split Pad (item no. 1181) has a conductor area of approximately 10 square inches and is intended for use when a larger pad is too big to use at the recommended placement site.

• Lightweight, conformable foam backing (white)

• Stress fl aps to secure the tab end of the pad

• Exceptional pad-to-skin contact from 3M’s gel-like, water-based (hydrophilic) conductive adhesive

• Non-conductive border adhesive

Available in Split and Solid Styles, With or Without Pre-Attached Cords

An electrosurgical pad should be placed on a well-vascularized muscular surface. However, the traditional 20 square-inch pads can be difficult to place, making the Medline Universal Pad with Safety Ring an excellent choice.

Large pads are difficult to place on patients who are:

• Small in size and weight• Emaciated• Elderly• Lacking in muscle tissue• Afflicted with a skin malady• Suffering from burns over a signifi cant

percentage of the body

Availability of sites for the placement of electrosurgical pads is reduced by the presence of:

• Scar tissue• Bony prominences• Implants• Pacemakers• Excessive hair• Weight bearing sites• Burns over a signifi cant percentage of the body• A skin surface where fl uid might pool

Additional benefi ts of the smaller size of the Medline Universal Pad include:

• More convenient handling• Less area on patient to prep• A greater number of suitable placement sites

The small size, shape and thin – but tough – construction of the Medline Universal Pad 9100 Series encourages optimum use by eliminating the need for compromise on pad application sites. Since only a small area is needed for application, this pad will fi t a greater number of suitable sites on the patient’s body.

SAFE ELECTROSURGICAL PAD PLACEMENT CAN BE A CHALLENGE. THE MEDLINE UNIVERSAL PAD WITH SAFETY RING IS THE SOLUTION.

Page 9: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

padspencils

electrodesaccessories

forcepsgenerators

support1-800-MEDLINE | www.medline.com 9

padsp

ads

1179 1180 1149 1149C-LP 1181

1100 SeriesITEM # DESCRIPTION CONDUCTIVE

ADHESIVE AREA PACKAGE

1149 Large (Non-Split) Pad, Non-Corded 20 sq. inches (129 sq. cm) 1/pouch, 100/cs

1149C-LP Large (Non-Split) Pad, Precorded with Large Plug 20 sq. inches (129 sq. cm) 1/pouch, 40/cs

1179 Large Split Pad, Precorded 20 sq. inches (129 sq. cm) 1/pouch, 40/cs1180 Large Split Pad, Non-Corded 20 sq. inches (129 sq. cm) 1/pouch, 100/cs1180F Large Split Pad, Non-Corded 20 sq. inches (129 sq. cm) 5/pouch, 200/cs1181 Small Split Pad, Precorded 10 sq. inches (64.5 sq. cm) 1/pouch, 40/cs

9100 SeriesITEM # DESCRIPTION CONDUCTIVE

ADHESIVE AREA PACKAGE

9165 Split, Precorded 15 sq. in. (97 sq. cm) 1/pouch, 40/cs9165L Split, Precorded with 15' Cord 15 sq. in. (97 sq. cm) 1/pouch, 40/cs9160 Split, Non-Corded 15 sq. in. (97 sq. cm) 1/pouch, 100/cs9160F Split, Non-Corded 15 sq. in. (97 sq. cm) 5/pouch, 200/cs9130 Standard (Non-Split), Non-Corded 15 sq. in. (97 sq. cm) 1/pouch, 100/cs9130F Standard (Non-Split), Non-Corded 15 sq. in. (97 sq. cm) 5/pouch, 200/cs

9135-LP Standard (Non-Split), Precorded with Large Plug 15 sq. in. (97 sq. cm) 1/pouch, 40/cs

9165 9160 9130 9135-LP

Page 10: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

1-800-MEDLINE | www.medline.com10

GROUNDING PADS

• Dollar savings Hospitals pay as much as 40% more for electrosurgical pads with pre-attached cords than for pads without pre-attached cords. Hospitals can enjoy considerable savings with multiple-use cables and non-corded pads.

• CompatibleThe 21100 line of cables and clamps is compatible with virtually all electrosurgical generators.

• AAMI standardsThe 21100 Series multiple-use cables and clamps meet standards set by the Association of the Advancement of Medical Instrumentation for Electrosurgical Devices, cables and accessories (ANSI/AAMI HF18:2001).

• Latex indicationNeither natural rubber latex nor dry natural rubber are components in 21100 Series multiple use cables and clamps or their packaging.

• ConvenientThe 21100 Series cables and clamps have chemical resistance and can be cleaned easily after use with a wide variety of cleaning materials. They can be exposed to the ETO sterilization process but must be aerated for 16 hours after ETO sterilization.

• Reduces potential for skin trauma The low profi le and smooth clamp assembly of the 21100 Series decreases the likelihood of skin trauma.

• Extra-strong holding forceThe 21100 Series clamp employs the “torturous path" concept in its design giving it a holding force that is secure and safe.

• Long life The strong design and materials used make the 21100 Series heavy duty and impact resistant.

Use of multiple-use cables means miles of copper wire will not become waste. And there is no PVC in 21100 Series multiple-use cables and clamps.

Multiple-use Cables

Page 11: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

padspencils

electrodesaccessories

forcepsgenerators

support1-800-MEDLINE | www.medline.com 11

ITEM # DESCRIPTION FOR USE WITH UNI-VERSAL 9100 SERIES

FOR USE WITH 1100 SERIES PLATES

PACKAGE

21172 10' (3.05 m) Reusable Cable for Solid Pads 9130, 9130F 1149, 1149F each

21174 10' (3.05 m) Reusable Cable for Split Pads 9160, 9160F 1180, 1180F each

21174L 15' (4.57 m) Reusable Cable for Split Pads 9160, 9160F 1180, 1180F each

21174ABC10' (3.05 m) Reusable Cable for Argon Beam Coagulators

9160, 9160F 1180, 1180F each

21100 Series

padsp

ads

Medline Reusable Cables (21100 Series)

21174

21174 shown with split pad attached

Page 12: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

Choose from sterile pencils in pushbutton,

rockerswitch and footswitch confi gurations.

Every pencil is packaged with a holster to help

promote AORN recommended practices.* Medline

also offers a pencil with a PTFE tip already attached;

this increases efficiency and eliminates waste as

non-stick tips no longer need to be pulled separately,

eliminating the cost of the stainless steel blade.

*Blanchard J, Burlingame B, eds. Perioperative Standards and Recommended Practices. AORN; 2011.

14 … VEGA SERIES

16 … CYGNUS SERIES

1-800-MEDLINE | www.medline.com12

ELECTROSURGICAL PENCILS

Page 13: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

padspencils

electrodesaccessories

forcepsgenerators

support1-800-MEDLINE | www.medline.com 13

Electrosurgical Pencils Designed exclusively for surgeons who prefer a more traditional feel, these pencils feature tactile buttons, less memory in the cords and high-quality plugs.

One piece NOSE

Nickel-plated PINS

Soft, fl exible CORD

Double-molded PLUG

Soft BUTTONS

pencilsp

encils

Page 14: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

1-800-MEDLINE | www.medline.com14

Standard Stainless Steel Tip, Sterile

ITEM # DESCRIPTION PACKAGE

ESPB3000 Push Button, Blade Electrode 50/cs

ESRK3000 Rocker Switch, Blade Electrode 50/cs

ESRK3000L Rocker Switch, Blade Electrode 15’ cord 50/cs

ESFS3000 Footswitch, Blade Electrode 50/cs

ESPB3000

ESRK3000

ESFS3000

Vega Series with Standard Stainless Steel Tip

• For most standard 2.4 mm (3/32 in.) shaft electrodes

• Manufactured to the highest quality standards in compliance with IEC Electrical Safety Standard 60601-2-2

• Fully guaranteed (see page 43 for Guarantee and Indemnifi cation Policy)

• Sterile and individually packaged with a safety holster

ELECTROSURGICAL PENCILS

Page 15: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

padspencils

electrodesaccessories

forcepsgenerators

support1-800-MEDLINE | www.medline.com 15

NON-STICK PERFORMANCE

• Allows the electrodes to be easily cleaned with a wet piece of gauze or sponge instead of an abrasive scratch pad

• Rounded edges prevent RF current from concentrating too much energy in one area

• All tips less than 3" in length feature ribbed insulation allowing for easy tip changes, even under wet conditions

Vega Series with Blue Silk® Non-Stick PTFE-Coated Tip Coated with PTFE, the Same Non-Stick Compound Used in Tefl on®

Blue Silk® PTFE Non-Stick Coated Tip, Sterile

ITEM # DESCRIPTION PACKAGE

ESPB3002 Push Button, Blue Silk, Non-Stick Blade 50/cs

ESRK3002 Rocker Switch, Blue Silk, Non-Stick Blade 50/cs

ESRK3002L Rocker Switch, Blade Electrode 15’ cord 50/cs

ESFS3002 Footswitch, Blue Silk, Non-Stick Blade 50/cs

ESPB3002

ESRK3002

ESFS3002

pencilsp

encils

Page 16: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

1-800-MEDLINE | www.medline.com16

Standard Stainless Steel Tip, Sterile

ITEM # DESCRIPTION PACKAGE

ESPB2000 Push Button, Blade Electrode 50/cs

ESPBN2000 Push Button, Needle Electrode 50/cs

ESRK2000 Rocker Switch, Blade Electrode 50/cs

ESFS2000 Foot Switch, Blade Electrode 50/cs

Cygnus Series with Standard Stainless Steel Tip

• The same great features as our Vega Series with a slightly different-shaped housing

• For most standard 2.4 mm (3/32 in.) shaft electrodes

• Manufactured to the highest quality standards in compliance with IEC Electrical Safety Standard 60601-2-2

• Fully guaranteed (see page 43 for Guarantee and Indemnity)

• Sterile and individually packaged with a safety holster

ESFS2000

ELECTROSURGICAL PENCILS

ESPBN2000

ESPB2000

ESRK2000

Page 17: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

padspencils

electrodesaccessories

forcepsgenerators

support1-800-MEDLINE | www.medline.com 171-1-80800-0-MMEMEDLDLINE | www.medline.co

High-quality active electrodes manufactured

to exacting tolerances. All tips under 3" have

ribbed insulation for easy tip changes, even under

wet conditions. Choose from a complete selection

of active electrodes. The standard 2.4 mm (0.09")

shafts fi t most electrosurgical pencils.

ELECTROSURGICAL ACTIVE ELECTRODES (TIPS)

18 … BLUE SILK® NON-STICK

PTFE-COATED ELECTRODES

20 … STAINLESS STEEL ELECTRODES

21 … LLETZ TUNGSTEN LOOP ELECTRODES

22 … ARTHROSCOPIC ELECTRODES

22 … MICROSURGICAL TUNGSTEN NEEDLES

23 … LAPAROSCOPIC INSTRUMENTS

17

padssupport

foorcrcepepssssssggegegeneneneeeerrarararararaattotototorsrsrs

117

padspencils

electrodesaccessories

forcepsgenerators

supportelectrodes

electrod

es

Page 18: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

1-800-MEDLINE | www.medline.com18

Coated with PTFE, the Same Non-Stick Compound Used in Tefl on®

• Standard 2.4 mm (3/32 in.) shaft designed to fi t most electrosurgical pencils

• Easily cleaned with a wet piece of gauze or sponge (as opposed to an abrasive scratch pad)

• Rounded blade edges prevent RF current from concentrating too much energy in one area

• Ribbed insulation for easy tip changes, even under wet conditions

Ribbed INSULATION

Rounded BLADE

Blue Silk® Non-Stick PTFE-Coated Electrodes, Single Use, Sterile

ITEM # DESCRIPTION PACKAGE

ES0012BL Blade Electrode, 2.5" (6.4 cm) 12/bx

ES0012A Blade Electrode 2.75" (7 cm) 12/bx

ES0012M Blade Electrode, Extended Insulation, 2.5" (6.4 cm) 12/bx

ES0012AM Blade Electrode, Extended Insulation, 2.75" (7 cm) 12/bx

ES0013 Needle Electrode, 2.75" (7 cm) 12/bx

ES0013M Needle Electrode, Extended Insulation, 2.75" (7 cm) 12/bx

ES0015 Ball Electrode, 0.06" (2 mm) Diameter, 2" Length (5.1 cm) 12/bx

ES0013

ES0012BLL

ES0012A

ES0012M

ES0012AM

ES0015

ES0013M

ELECTROSURGICAL ACTIVE ELECTRODES (TIPS)

Blue Silk® Non-Stick PTFE-Coated Electrodes, Single Use, Sterile

Page 19: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

padspencils

electrodesaccessories

forcepsgenerators

support1-800-MEDLINE | www.medline.com 19

NON-STICK PERFORMANCE

electrodeselectro

des

Blue Silk® Non-Stick PTFE-Coated Electrodes, Single Use, Sterile

ES0014AM

ES0014

ES0016AM

ES0014M

ES0016

ES0016MM

M

ES0009

Blue Silk® Non-Stick PTFE-Coated Electrodes, Single Use, Sterile

ITEM # DESCRIPTION PACKAGE

ES0014A Blade Electrode, 4" (10.16 cm) 12/bx

ES0014AM, Blade Electrode, Extended Insulation, 4" (10.16 cm) 12/bx

ES0014 Blade Electrode, 6” (15.24 cm) 12/bx

ES0014M Blade Electrode, Extended Insulation, 6” (15.24 cm) 12/bx

ES0016 Needle Electrode, 6” (15.24 cm) 12/bx

ES0016M Needle Electrode, Extended Insulation, 6” (15.24 cm) 12/bx

ES0016AM Needle Electrode, Extended Insulation, 4" (10.16 cm) 12/bx

ES0009 Ball Electrode, 0.19" (5 mm) Diameter, 5" Length (12.7 cm) 12/bx

ES0014A

Page 20: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

1-800-MEDLINE | www.medline.com20

Stainless Steel Electrodes, Single Use, Sterile

Standard 2.4 mm (3/32") Shaft, Designed to Fit Most Electrosurgical Pencils

Stainless Steel Electrodes, Single Use, Sterile

ITEM # DESCRIPTION PACKAGE

ESE1550 Ball Electrode, 0.19" (5 mm) Diameter, 2" Length 150/cs

ESE1552 Needle Electrode, 2.84" (7.2 cm) 150/cs

ESE155250 Needle Electrode, 2.84" (7.2 cm) 50/cs

ESE1551X Blade Electrode, with Hex, 2.75" (7 cm) 150/cs

ESE1551IX Blade Electrode, with Hex, Extended Insulation, 2.75" (7 cm) 150/cs

ESE1552I Needle Electrode, Extended Insulation, 2.84" (7.2 cm) 50/cs

ESE15516 Extended Blade Electrode, 6" (15.2 cm) 50/cs

ESE15516IX Extended Blade Electrode, with Hex, Extended Insulation, 6.5" (16.5 cm) 50/cs

ESE15526 Extended Needle Electrode, 6" (15.2 cm) 50/cs

ELECTROSURGICAL ACTIVE ELECTRODES (TIPS)

ESE155265526

ESE15516

ESE1550SEE1550

ESE1552

ESE1551X

ESE1552I

ESE1551IX

ESE1556IX

SE155526

6

ESEE1552I1552I

56IX

Page 21: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

padspencils

electrodesaccessories

forcepsgenerators

support1-800-MEDLINE | www.medline.com 21

Lletz Tungsten Loop Electrodes, Single Use, Sterile

ITEM # DESCRIPTION PACKAGE

ESE1559 Tungsten Loop, 10 mm x 10 mm, 13 cm Length 10/cs

ESE1560 Tungsten Loop, 15 mm x 12 mm, 13 cm Length 10/cs

ESE1561 Tungsten Loop, 20 mm x 12 mm, 13 cm Length 10/cs

ESE1562 Tungsten Loop, 20 mm x 15 mm, 13 cm Length 10/cs

ESE1563 Stainless Steel Ball, 3 mm diameter, 13 cm Length 10/cs

ESE1564 Stainless Steel Ball, 5 mm diameter, 13 cm Length 10/cs

ESE1565 Tungsten Square, 5 mm x 5 mm, 13 cm Length 10/cs

ESE1566 Tungsten Square, 10 mm x 4 mm, 13 cm Length 10/cs

ESE1567 Tungsten Square Loop, 10 mm x 8 mm, 13 cm Length 10/cs

Lletz Tungsten Loop Electrodes, Single Use, Sterile

Standard 2.4 mm (3/32") Shaft, Designed to Fit Most Electrosurgical Pencils

ESE1560

ESE1561

SE1560SE1560

ESE1561

ESE1562

Standard 2.4 mm (3/32") Shaft, Designed to Fit Most Electr

ESE1559

ESE1564

ESE1563

64

ESE156565

ESE1566566

ESE1567

electrodeselectro

des

Page 22: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

1-800-MEDLINE | www.medline.com22

ELECTROSURGICAL ACTIVE ELECTRODES (TIPS)

Arthroscopic Electrodes, Single Use, SterileStandard 2.4 mm (3/32") Shaft, Designed to Fit Most Electrosurgical Pencils

copic Electrodes,

ESE151015

ESE1511

ESE1512

10

1511

SE1512

Arthroscopic Electrodes, Single Use, Sterile

ITEM # DESCRIPTION PACKAGE

ESE1510 Right Angle Hook Electrode, Insulated, with Safety Cap, 8.5" (21.6 cm) 10/cs

ESE1511 45° Angle Hook Electrode, Insulated, with Safety Cap, 8.5" (21.6 cm) 10/cs

ESE1512 Angled Blade Electrode, Insulated, with Safety Cap, 8.5" (21.6 cm) 10/cs

Microsurgical Tungsten Needles, Single Use, SterileStandard 2.4 mm (3/32") Shaft, Designed to Fit Most Electrosurgical Pencils

ESE1650

ESE1651

Microsurgical Tungsten Needles, Single Use, Sterile

ITEM # DESCRIPTION PACKAGE

ESE1650 Tungsten Needle with Insulation, 2 cm Straight 10/cs

ESE1651 Tungsten Needle with Insulation, 3 cm Straight 10/cs

Page 23: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

padspencils

electrodesaccessories

forcepsgenerators

support1-800-MEDLINE | www.medline.com 23

electrodeselectro

des

Solid Laparoscopic Electrodes, Single Use, SterileStandard 2.4 mm (3/32") Shaft, Designed to Fit Laparoscopic Hand Units – Electrodes Fit 5 mm Trocar Cannulas

ESE277428

ESE277328

ESE277228

ESE277128

ESE277028

Lletz Tungsten Loop Electrodes, Single Use, Sterile

ITEM # DESCRIPTION PACKAGE

ESE277028 Straight Spatula Tip, 11" (28 cm) 10/cs

ESE277128 Curved Spatula Tip, 11" (28 cm) 10/cs

ESE277228 Wire J Hook Tip, 11" (28 cm) 10/cs

ESE277328 Wire L Hook Tip, 11" (28 cm) 10/cs

ESE277428 Flat L Hook Tip, 11" (28 cm) 10/cs

Page 24: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

24

Electrosurgical accessories, such as tip cleaners

and bipolar cords, can be as vital to a procedure

as your Bovie generator. Safety holsters for holding

cautery pencils when not in use (available separately)

are recommended by the AORN and can be invaluable

in helping to protect your patients and staff.* To ensure

that you never run out of any electrosurgical product,

you need a supplier who offers quick turnaround

times and outstanding service. Medline maintains 32

distribution centers, strategically located throughout the

US, with over 8 million square feet of product storage.

With such vast resources, Medline can deliver the

products you need, when you need them.

*Blanchard J, Burlingame B, eds. Perioperative Standards and Recommended Practices. AORN; 2011.

 

ACCESSORIES

AORN and can be invaluable

tect your patients and staff.* To ensure

never run out of any electrosurgical product,

u need a supplier who offers quick turnaround

times and outstanding service. Medline maintains 32

distribution centers, strategically located throughout the

US, with over 8 million square feet of product storaagege.

With such vast resources, Medline can deliveveeerr rrrr tthttthththtthththhheeee e e

products you need, when you need thehem.

*Blanchard J, Burlingame B, eds. Perioperaeratitive SStatandararrddds ds anddddndd Recommended Practices. AORN; 201111.

1-800-MEDLINE | www.medline.com

Page 25: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

padspencils

electrodesaccessories

forcepsgenerators

support1-800-MEDLINE | www.medline.com 25

padspencils

generatorssupport

padspencils

electrodesaccessories

forcepsgenerators

support

Electrosurgical Tip Cleaner• For quick-and-easy cleaning of

cautery tips during surgery

• Radiopaque

• Sturdy adhesive backing can be secured anywhere with ease

Electrosurgical Tip Cleaner, Sterile

ITEM # DESCRIPTION PACKAGE

DYNJ01208 Cautery Tip Polisher, 2" x 2" (5 cm x 5 cm) 100/cs

Electrosurgical Safety Holster• For placement of pencils when not in use

• Sturdy, non-conductive plastic

• Large clip for easy attachment to drape or stand

Electrosurgical Safety Holster

ITEM # DESCRIPTION PACKAGE

ESH1 Electrosurgical Safety Holster 30/cs

Bipolar Cord • Manufactured with the highest grade

of insulating materials available

• 12’ in length

• Fit all standard forceps

Bipolar Cord

ITEM # DESCRIPTION PACKAGE

DYNJ01207 Disposable Bipolar Cord, Sterile 50/cs

accessoriesaccesso

ries

Page 26: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

1-800-MEDLINE | www.medline.com26 1-800-MEDLINE | www.medline.com26 ne com

Bipolar forceps play an important role in

precise hemostasis. Medline’s high-quality

bipolar forceps are reusable and fully autoclavable,

helping you control and reduce surgical procedure

costs. Choose from the following selection of

forceps for use across all surgical procedures.

REUSABLE BIPOLAR FORCEPS

27 … STRAIGHT BIPOLAR FORCEPS

30 … BAYONET BIPOLAR FORCEPS

33 … REUSABLE ACCESSORIES

Page 27: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

padspencils

electrodesaccessories

forcepsgenerators

support1-800-MEDLINE | www.medline.com 27

Straight Bipolar Forceps – Footswitching, 2-Pin Connection Special Micro and Ophthalmic Bipolar Forceps

Adson

ITEM # SIZE DESCRIPTION PACKAGE

MDS571004C 4.75" (12 cm) Insulated, Straight Tip each

MDS571104C 4.75" (12 cm) Insulated, Angled Tip each

MDS571204C 4.75" (12 cm) Non-Insulated, Straight Tip each

MDS571304C 4.75" (12 cm) Non-Insulated, Angled Tip each

* Please note: items are only available with a 1.0 mm tip.

Jewelers

ITEM # SIZE DESCRIPTION PACKAGE

MDS572004E 4.25" (10.7 cm) Insulated, Straight Tip each

MDS572104E 4.25" (10.7 cm) Insulated, Angled Tip each

MDS572204E 4.25" (10.7 cm) Non-Insulated, Straight Tip each

MDS572304E 4.25" (10.7 cm) Non-Insulated, Angled Tip each

Please note: items are only available with a needle tip.

Iris

ITEM # SIZE DESCRIPTION PACKAGE

MDS573004E 3.75" (9.5 cm) Insulated, Straight Tip each

MDS573104E 3.75" (9.5 cm) Insulated, Angled Tip each

MDS573204E 3.75" (9.5 cm) Non-Insulated, Straight Tip each

MDS573304E 3.75" (9.5 cm) Non-Insulated, Angled Tip each

Please note: items are only available with a needle tip.

MDS572004E

MDS573004

MDS571005D

forcepsfo

rceps

More lengths available —ask your Medline representative.

TIP SIZE SPECIFICATIONS

B1.5 mm

A2.0 mm

ENEEDLE

D0.5 mm

C1.0 mm

Page 28: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

1-800-MEDLINE | www.medline.com28

REUSABLE BIPOLAR FORCEPS

McPherson

ITEM # SIZE DESCRIPTION PACKAGE

MDS574004D 4.25" (10.7 cm) Insulated, Straight Tip each

MDS574104D 4.25" (10.7 cm) Insulated, Angled Tip each

MDS574204D 4.25" (10.7 cm) Non-Insulated, Straight Tip each

MDS574304D 4.25" (10.7 cm) Non-Insulated, Angled Tip each

Please note: items are only available with a 0.5 mm tip.

Coaptation

ITEM # SIZE DESCRIPTION PACKAGE

MDS575104* 4.75" (12 cm) Insulated, Angled Tip each

MDS575304* 4.75" (12 cm) Non-Insulated, Angled Tip each

* To select your tip, add “D” for 0.5 mm or “E” for needle to the end of the item number.

FPO

Special Micro and Ophthalmic Bipolar Forceps

Straight Bipolar Forceps – Footswitching, 2-Pin Connection

More lengths available — ask your Medline representative.

Malis

ITEM # SIZE DESCRIPTION PACKAGE

MDS587007* 6.25" (16 cm) Insulated, Straight Tip each

MDS587207* 6.25" (16 cm) Non-Insulated, Straight Tip each

MDS587008 6.75" (17 cm) Insulated, Straight Tip each

MDS587208 6.75" (17 cm) Non-Insulated, Straight Tip each

* To select your tip, add “D” for 0.5 mm, or “E” for needle to the end of the item number.

MDS575304

MDS574204D

y

TION PAC

MDS587007

Page 29: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

padspencils

electrodesaccessories

forcepsgenerators

support1-800-MEDLINE | www.medline.com 29

Cushing

ITEM # SIZE DESCRIPTION PACKAGE

MDS581006* 6.75" (17 cm) Insulated, Straight Tip each

MDS581106* 6.75" (17 cm) Insulated, Angled Tip each

MDS581206* 6.75" (17 cm) Non-Insulated, Straight Tip each

MDS581306* 6.75" (17 cm) Non-Insulated, Angled Tip each

MDS581007* 7.75" (19.7 cm) Insulated, Straight Tip each

MDS581107* 7.75" (19.7 cm) Insulated, Angled Tip each

MDS581207* 7.75" (19.7 cm) Non-Insulated, Straight Tip each

MDS581307* 7.75" (19.7 cm) Non-Insulated, Angled Tip each

* T o select your tip, add “A” for 2.0 mm, “B” for 1.5 mm, “C” for 1.0 mm, “D” for 0.5 mm, or “E” for needle to the end of the item number.

Gerald

ITEM # SIZE DESCRIPTION PACKAGE

MDS586006C 6.75" (17 cm) Insulated, Straight Tip each

MDS586206C 6.75" (17 cm) Non-Insulated, Straight Tip each

MDS586007C 7.75" (19.7 cm) Insulated, Straight Tip each

MDS586207C 7.75" (19.7 cm) Non-Insulated, Straight Tip each

Please note: items are only available with a 1.0 mm tip.

FPO

Semkin

ITEM # SIZE DESCRIPTION PACKAGE

MDS589009E 6.75" (17 cm) Insulated, Straight Tip each

MDS589209E 6.75" (17 cm) Non-Insulated, Straight Tip each

Please note: items are only available with a needle tip.

MDS586007C

MDS581007

MDS589006E

forcepsfo

rceps

More lengths available —ask your Medline representative.

TIP SIZE SPECIFICATIONS

B1.5 mm

A2.0 mm

ENEEDLE

D0.5 mm

C1.0 mm

Page 30: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

1-800-MEDLINE | www.medline.com30

REUSABLE BIPOLAR FORCEPS

More lengths available — ask your Medline representative.

Rhoton

ITEM # SIZE DESCRIPTION PACKAGE

MDS598007* 7.75" (19.7 cm) Insulated, Straight Tip each

MDS598107* 7.75" (19.7 cm) Insulated, Angled Tip each

MDS598207* 7.75" (19.7 cm) Non-Insulated, Straight Tip each

MDS598307* 7.75" (19.7 cm) Non-Insulated, Angled Tip each

MDS598008* 8.75" (22 cm) Insulated, Straight Tip each

MDS598108* 8.75" (22 cm) Insulated, Angled Tip each

MDS598208* 8.75" (22 cm) Non-Insulated, Straight Tip each

MDS598308* 8.75" (22 cm) Non-Insulated, Angled Tip each

* To select your tip, add “A” for 2.0 mm, “B” for 1.5 mm, “C” for 1.0 mm, “D” for 0.5 mm, or “E” for needle to the end of the item number.

MDS598007

* To select your tip, add “A” for 2.0 mm, “B” for 1.5 mm, “C” for 1.0 mm, “D” for 0.5 mm, or “E” for needle to the end of the item number.

Hardy

ITEM # SIZE DESCRIPTION PACKAGE

MDS599008* 8.75" (22 cm) Insulated, Straight Tip each

MDS599208* 8.75" (22 cm) Non-Insulated, Straight Tip each

MDS599009* 9.75" (24.7 cm) Insulated, Straight Tip each

MDS599209* 9.75" (24.7 cm) Non-Insulated, Straight Tip each

MDS599008

Bayonet Bipolar Forceps – Footswitching, 2-Pin Connection

Page 31: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

padspencils

electrodesaccessories

forcepsgenerators

support1-800-MEDLINE | www.medline.com 31

Scoville Greenwood

ITEM # SIZE DESCRIPTION PACKAGE

MDS594007* 7.75" (19.7 cm) Insulated, Straight Tip each

MDS594207* 7.75" (19.7 cm) Non-Insulated, Straight Tip each

MDS594008* 8.75" (22 cm) Insulated, Straight Tip each

MDS594208* 8.75" (22 cm) Non-Insulated, Straight Tip each

* To select your tip, add “A” for 2.0 mm, “B” for 1.5 mm, “C” for 1.0 mm, “D” for 0.5 mm, or “E” for needle to the end of the item number.

MDS594007

Yasargil

ITEM # SIZE DESCRIPTION PACKAGE

MDS595006* 7" (17.8 cm) Insulated, Straight Tip each

MDS595206* 7" (17.8 cm) Non-Insulated, Straight Tip each

MDS595007* 8" (20.3 cm) Insulated, Straight Tip each

MDS595207* 8" (20.3 cm) Non-Insulated, Straight Tip each

* To select your tip, add “A” for 2.0 mm, “B” for 1.5 mm, “C” for 1.0 mm, “D” for 0.5 mm, or “E” for needle to the end of the item number.

MDS595007

forcepsfo

rceps

More lengths available —ask your Medline representative.

TIP SIZE SPECIFICATIONS

B1.5 mm

A2.0 mm

ENEEDLE

D0.5 mm

C1.0 mm

Page 32: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

1-800-MEDLINE | www.medline.com32

REUSABLE BIPOLAR FORCEPS

More lengths available — ask your Medline representative.

Malis

ITEM # SIZE DESCRIPTION PACKAGE

MDS597008* 7.75" (19.7 cm) Insulated, Straight Tip each

MDS597108* 7.75" (19.7 cm) Insulated, Angled Tip each

MDS597208* 7.75" (19.7 cm) Non-Insulated, Straight Tip each

MDS597308* 7.75" (19.7 cm) Non-Insulated, Angled Tip each

MDS597009* 8.75" (22 cm) Insulated, Straight Tip each

MDS597109* 8.75" (22 cm) Insulated, Angled Tip each

MDS597209* 8.75" (22 cm) Non-Insulated, Straight Tip each

MDS597309* 8.75" (22 cm) Non-Insulated, Angled Tip each

* To select your tip, add “A” for 2.0 mm, “B” for 1.5 mm, “C” for 1.0 mm, “D” for 0.5 mm, or “E” for needle to the end of the item number.

FPO

Please note: items ending in “C” are only available with a 1.0 mm tip.

Gerald

ITEM # SIZE DESCRIPTION PACKAGE

MDS596006C 6.75" (17 cm) Insulated, Straight Tip each

MDS596206C 6.75" (17 cm) Non-Insulated, Straight Tip each

MDS596007C 7.75" (19.7 cm) Insulated, Straight Tip each

MDS596207C 7.75" (19.7 cm) Non-Insulated, Straight Tip each

MDS596007C

MDS597009

Bayonet Bipolar Forceps – Footswitching, 2-Pin Connection

Page 33: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

padspencils

electrodesaccessories

forcepsgenerators

support1-800-MEDLINE | www.medline.com 33

Cushing

ITEM # SIZE DESCRIPTION PACKAGE

MDS591007* 7.75" (19.7 cm) Insulated, Straight Tip each

MDS591107* 7.75" (19.7 cm) Insulated, Angled Tip each

MDS591207* 7.75" (19.7 cm) Non-Insulated, Straight Tip each

MDS591307* 7.75" (19.7 cm) Non-Insulated, Angled Tip each

MDS591008* 8.75" (22 cm) Insulated, Straight Tip each

MDS591108* 8.75" (22 cm) Insulated, Angled Tip each

MDS591208* 8.75" (22 cm) Non-Insulated, Straight Tip each

MDS591308* 8.75" (22 cm) Non-Insulated, Angled Tip each

MDS591010* 10.75" (27.3 cm) Insulated, Straight Tip each

MDS591110* 10.75" (27.3 cm) Insulated, Angled Tip each

MDS591210* 10.75" (27.3 cm) Non-Insulated, Straight Tip each

MDS591310* 10.75" (27.3 cm) Non-Insulated, Angled Tip each

* To select your tip, add “A” for 2.0 mm, “B” for 1.5 mm, “C” for 1.0 mm, “D” for 0.5 mm, or “E” for needle to the end of the item number.

MDS591008

Reusable Accessories• Manufactured with the highest grade

of insulating materials available• 10’ in length• Fit all standard forceps

Reusable Bipolar Cord

ITEM # DESCRIPTION PACKAGE

MDS5990 Reusable Bipolar Cord, 10 ft (3.0 M) each

forcepsfo

rceps

More lengths available —ask your Medline representative.

TIP SIZE SPECIFICATIONS

B1.5 mm

A2.0 mm

ENEEDLE

D0.5 mm

C1.0 mm

Page 34: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

There is no name more synonymous with electrosurgery than

Bovie. Dr. Bovie pioneered the use of electrosurgery more than

80 years ago, and many people still refer to their electrosurgical

equipment as their “Bovie.” Medline is proud to be the US distributor

of Bovie Electrosurgical generators.

Bovie generators feature fully digital implementation for use in

today’s modern OR and surgical outpatient centers. They’re easy to

handle yet capable of covering the whole spectrum of electrosurgical

interventions. The generator technology gives surgeons the fl exibility

to choose the desired type of effect with maximum convenience and

safety. Controlling the unit is easy, so the surgeon can concentrate on

what’s important – the operation and the patient.

refer to their electrosurgical

e.” Medline is proud to be the US distributor

urgical generators.

enerators feature fully digital implementation for use in

ay’s modern OR R anand d surgical outpatient centers. They’re easy to

handle yyyeet capable of coveriingngg ttheh wwhohole spectrum of electrosurgical

inteetervrveneentitiononnnono ss. The genererratattttoroooro ttecececece hnhnhnhnhnh olololoologogy gives susurgrgeons the fl exibility

toto ccchhohohooososee thht e e dededddddd isired tytytyypepepee oooffff efefeffeefefectcct wwwititithhh mamaaaxixix mum m convvenenience and

ssasafffetytyty. CConttttrororor llllllllinnnnininnggggggggggg ththe ununnnnnnnnnnnnnnnn titititit iiiisssssss eaeaeaeaeeasysysy,, sosososo tttheheeheheeeeee sssssssssssssuuuruuuuuuuuuuuuuuuuuruuuuruuuuuruu geon canan cconcentraratete on

wwhwhata ’ssss iiiimpmppororrrorro tataatantntntnttt –––– ttttttttthehhhhhhhehhhh ooppppepeppepepepepepeeeeeeeeeepeeeeeeeeerararaaarararraatittiononononononnonnononononnnnnnnoon aaaaaaaaaaaaaaaaaaaaaaaaaanndndndndndndndndndnnndndnnddndnddnd tttttttttttttttthehehehheehhhehhhhhh ppppppppppppppppaaaaaaataataaaaaaa ient.

BOVIE® GENERATORS, SMOKE EVACUATORS

36 … BOVIE ICON GP ELECTROSURGICAL

GENERATORS

38 … BOVIE IDS ELECTROSURGICAL

GENERATORS

40 … BOVIE SMOKE EVACUATOR

1-800-MEDLINE | www.medline.com34

Page 35: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

padspencils

electrodesaccessories

forcepsgenerators

support1-800-MEDLINE | www.medline.com 35

padspencils

electrodesaccessories

padspencils

electrodesaccessories

forcepsgenerators

support

Bovie® Generators – the Most Recognized Name in Electrosurgery

SAFETY FEATURES

Safety is digitally designed inside

every model. The technology meets

the requirements of a variety of medical

specialties, procedures and indications in

the modern OR.

BovieFDFS™ (Fast Digital Feedback System)

This digitally controlled cut and coagulation

function senses tissue changes at a rate of

over 5 million times per second, for the most

consistent energy delivery available – no

other generator manufacturer today can

say that. FDFS controls tissue impedance

in real time, and adjusts power 5,000 times

per second, for an absolutely consistent

clinical effect.

BovieNEM™ (Neutral Electrode Monitoring)

The most advanced technology available for

preventing pad burns.

BovieFCFS™ (First Come First Served)

Discrete output design allows only one

output device to be activated at a time.

BovieDED™ (Digital Error Detection)

At any sign of a problem, the unit instantly

disables the output, sounds an alarm and

displays the appropriate error code.

Fully Digital ImplementationBovie generators do not require any

calibration.

EASY FINANCING

Medline offers several options to fi nance

the purchase of your new electrosurgical

generators. We offer capital purchase

fi nancing up to three years (interest-free up

to one year).* We can also build the cost of

the generators into your future sterile (off-

the-shelf) purchases or custom procedure

trays. Choose the payment plan that’s right

for you.

OUTSTANDING SERVICE

• 8-year warranty – the longest service

plan in the industry

• All Bovie generators ship FOB-

destination – FREE Freight

• Buy back availability for your old units

• Products and support available for trials

*Certain conditions may apply; specifi c fi nancing conditions are evaluated on a case-by-case basis.

generatorsg

enerato

rs

Page 36: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

1-800-MEDLINE | www.medline.com36

Bovie Icon GP Electrosurgical GeneratorThe Icon GP is an intuitive electrosurgical generator with fully digital

implementation for use in today’s modern operating rooms. It was

designed in conjunction with OR clinicians to provide a safe, user-

friendly unit that can meet all operating room procedure demands.

A WIDE VARIETY OF MODES

Cut Modes

• Pure cut – Digitally controlled 300W maximum power ensures consistent performance

• Blended Cut – Three blend settings allow the surgeon to cut and coagulate at the same time

• Laparoscopic cut – Helps prevent capacitive coupling

• Special mode – Optimized for fl uid environments or may be tailored for a variety of applications

Coagulation Modes

• Pinpoint – Delivers rapid desiccation effect with minimal carbonization and less sticking of the active electrode

• Gentle – A gentler mode without carbonization

• Spray – Non-contact mode for controlling superfi cial bleeding

• Laparoscopic – Reduces risk of capacitive coupling

Bipolar Modes:

• Macro coagulation – Aggressive coagulation

• Micro coagulation – For precise applications

• Gentle coagulation – A gentler mode without carbonization

• Auto stop – Provides for extra convenience

SAFETY

• Bovie NEM, the most advanced safety technology available to help prevent pad burns

• Requires the use of only split pads for increased patient safety

• Laparoscopic modes help prevent capacitive coupling-induced burns

• Common sense error messaging prevents misinterpretation and allows for quicker troubleshooting

EASY TO USE

• Physician preference database facilitates quick changeovers

• Touch-screen interface with high-resolution TFT color display (no buttons or knobs)

• Swivel screen can be viewed from virtually any angle

UPGRADABLE

• Digitally controlled outputs and user interface make adding new modes easy

• Multiple communication ports (i.e., USB, RS 232 and Ethernet) allow for easy software updates

• New-accessory connector for future devices

BOVIE® GENERATORS

Page 37: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

padspencils

electrodesaccessories

forcepsgenerators

support1-800-MEDLINE | www.medline.com 37

Icon GP Specifi cations

Reference GP 300Output Type RF Isolated “F"Output Power

Pure Cut 300W @ 300ΩBlend 200W @ 300ΩLaparoscopic Cut 300W @ 300ΩSpecial Cut 300W @ 300ΩPinpoint Coag 120W @ 500ΩSpray Coag 120W @ 500ΩLaparoscopic Coag 120W @ 500ΩGentle Coag 120W @ 125ΩMacro Bipolar 80W @ 100ΩMicro Bipolar 80W @ 100ΩAuto Stop 80W @ 100ΩGentle Bipolar 50W @ 25ΩOutput Frequency 492 kHz ±5

Line Voltage 100-240 VAC 50-60 Hz

Bovie Icon GP

ITEM # DESCRIPTION PACKAGE

ESUICONGP Electrosurgical Generator Icon GP each

ESUFOOTICON Monopolar Footswitch for Icon GP each

ESUFOOTGPB Bipolar Footswitch for Icon GP each

ESUADAPTOR Adapter for Footswitch Accessories each

ESUCARTGP Mobile Cart for Icon GP each

ESUICONGPC Icon GP Generator Plus Cart and Accessories (includes ESUICONGP, ESUFOOTICON, ESUFOOTGPB, ESUCARTGP) each

ESUFOOTICON ESUADAPTORESUFOOTGPB

generatorsg

enerato

rs

Page 38: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

1-800-MEDLINE | www.medline.com38

EASY TO USE

• Plug and play – just plug the unit in and it’s ready to use

• No calibration required

CUTTING MODES

• Cut I Mode – A digitally controlled cutting quality that ensures performance when cutting adipose tissue or cutting underwater with minimal output power.

• Cut II Mode – A less aggressive cutting effect with the highest degree of safety for precise effects in general applications or microsurgery.

• Blended Cut – Ten blend settings allow the surgeon to cut and coagulate at the same time

COAGULATION MODES

• Pinpoint Coagulation Mode – Delivers a digitally controlled rapid desiccation effect with minimal carbonization and less sticking of the active electrode.

• Spray Coagulation Mode – Gives digitally controlled non-contact coagulation with a slight penetration of the tissue surface.

BIPOLAR MODE

• Uses digital technology to reduce instrument sticking and to minimize tissue destruction

The Surgeon’s Preset Center (IDS300 only) allows up to 10 surgeons to store their preferred power settings in the cut, coagulation, and bipolar modes.

Bovie IDS Electrosurgical GeneratorBovie IDS electrosurgical generators

provide a consistent clinical effect.

They’re easy to use, capable of

covering a whole spectrum of

electrosurgical interventions

and backed by the Bovie name.

BOVIE® GENERATORS

Page 39: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

padspencils

electrodesaccessories

forcepsgenerators

support1-800-MEDLINE | www.medline.com 39

IDS Specifi cations

Reference IDS-300 IDS-200Output Type RF Isolated RF Isolated “F"Output Power

Cut I & II 300 W @ 300 Ω 200 W @ 300 Ω Blend 200 W @ 300 Ω 200 W @ 300 Ω Pinpoint 120 W @ 500 Ω 120 W @ 500 Ω Spray 80 W @ 500 Ω 80 W @ 500 Ω Bipolar 80 W @ 150 Ω 80 W @ 150 Ω

Duty Cycle 10 S / 30 S 10 S / 30 SOutput Frequency

490 kHz ± 5 490 kHz ± 5

Input Current 4.5 A ~ 4.5 A ~Line Voltage 100 - 240 V ~ 100 - 240 V ~Line Frequency 50-60 Hz 50-60 Hz

Bovie IDS

ITEM # DESCRIPTION PACKAGE

ESUIDS300 IDS-300 Electrosurgical Generator (300w) each

ESUIDS200 IDS-200 Electrosurgical Generator (200w) each

ESUFOOTSWITCH Monopolar Footswitch for Bovie IDS each

ESUFOOTSWICHB Bipolar Footswitch for Bovie IDS each

ESUADAPTOR Adapter for Footswitch Accessories each

ESUCART Mobile Cart for IDS generators each

ESUIDS300CIDS-300 Generator Plus Cart and Accessories (package includes ESUIDS300, ESUFOOTSWITCH, ESUFOOTSWICHB, ESUCART)

each

ESUIDS200CIDS-200 Generator Plus cart and Accessories (package includes ESUIDS200, ESUFOOTSWITCH, ESUFOOTSWICHB, ESUCART)

each

ESUFOOTSWITCH ESUADAPTORESUFOOTSWICHB

generatorsg

enerato

rs

Page 40: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

1-800-MEDLINE | www.medline.com40

Bovie Smoke Shark™ The easy-to-use Bovie Smoke Shark is extremely effective at smoke and particle removal at

the operative site. Although it’s designed for use with electrosurgical generators, the Smoke

Shark is also excellent for controlling laser smoke.aser smoke.

Smoke Evacuator Specifi cations

DimensionsHeight 29.9 cm (11.8")Width 17.8 cm (7.0")Depth 46.4 cm (18.3")Weight < 6.5 kg (< 14 lbs.)

w/o fi lterLine Voltage SE01: 120 VAC

SE01-220: 240 VACLine Frequency 50 – 60 HzWarranty 2 years

Bovie Smoke Shark

ITEM # DESCRIPTION PACKAGE

ESUSMOKE Bovie Smoke Shark (does not inclue fi lter or tubing) each

ESUFILTER Smoke Evacuator 18-Hour Filter each

ARN786TSBX Sterile Tubing 24/cs

ARNSETWS Sterile Tubing with Wand 24/cs

BOVIE® SMOKE EVACUATORS

LONG-LIFE 18-HOUR FILTER

• Cost-effective – Combines four-stage fi ltration into one casing (pre-fi lter, ULPA, carbon, post-fi lter), keeping cost per procedure down and minimizing waste

• Powerful – Captures particles down to 0.01 µm with 99.99995% effi cacy

• Eliminates odors – Provides superior odor elimination via the 24 ounces of carbon in the fi lter

A SLEEK, POWERFUL,

SMOKE-EATING MACHINE!

• Easy to operate

• Quiet and effective

• Long-life, 18-hour fi lter

• Low cost per procedure

• Excellent particle capture

• Quality made in the U.S.A.

Page 41: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

padspencils

electrodesaccessories

forcepsgenerators

support1-800-MEDLINE | www.medline.com 41

8000 Series

ITEM # DESCRIPTION PACKAGE

ESPB8000 Pencil, Push Button, Stainless Steel Tip, 1' Tubing 30/cs

ESRK8000 Pencil, Rocker, Stainless Steel Tip, 1' Tubing 30/cs

ESPB8002 Pencil, Push Button, PTFE Tip, 1' Tubing 30/cs

ESRK8002 Pencil, Rocker, PTFE Tip, 1' Tubing 30/cs

ESADPSM Adapter for Pencils, 1' Tubing 30/cs

ACCESSORIES

Electrosurgical Pencils with Smoke Evacuator Tubing

• A versatile tool in providing hands-free capture of hazardous electrosurgical plume

• Eliminates the need for another clinician to hold the tubing

• Ergonomic design features pliable silicone for extra comfort and visibility

• Easy clog removal

• Latex free

• The 8000 series pencils feature 3/8” diameter by 1’ tubing, with a 3/8” to 3/8” connector – ideal for use with wall suction systems

• The 9000 series pencils feature a total of 10’ tubing: 3/8” x 4’ tubing connected to 6’ x 7/8” tubing – ideal for use with smoke evacuation systems

9000 Series

ITEM # DESCRIPTION PACKAGE

ESPB9000 Pencil, Push Button, Stainless Steel Tip, 10' Tubing 16/cs

ESRK9000 Pencil, Rocker, Stainless Steel Tip, 10' Tubing 16/cs

ESPB9002 Pencil, Push Button, PTFE Tip, 10' Tubing 16/cs

ESRK9002 Pencil, Rocker, PTFE Tip, 10' Tubing 16/cs

ESADP10 Adapter for Pencils, 10' Tubing 16/cs

generatorsevacu

ators

Page 42: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

SERVICE AND SUPPORT

OUR GUARANTEE

Medline stands behind the quality of our electrosurgical products,

whether they’re used on Bovie generators or other major brands

of generators in the market. Details are on the next page, in our

Guarantee and Indemnifi cation Policy.

ONGOING SUPPORT

We not only warranty our own generators, but those of our

competitors as well, at no charge, provided they are less than

eight years old – a Medline exclusive. So if you’re being told that

purchasing disposable electrosurgical products from another

company will void the warranty of your generator, don’t worry!

Medline will assume the warranty for you.*

We can also provide service on your generators

that are over 8 years old, and simply charge on

an as-needed basis.

*Certain conditions may apply.

1-800-MEDLINE | www.medline.com42

Page 43: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

padspencils

electrodesaccessories

forcepsgenerators

support1-800-MEDLINE | www.medline.com 43

Guarantee: Medline Industries, Inc. fully recognizes its responsibilities as a manufacturer of healthcare products and warrants that reasonable care was used in the manufacture of its electrosurgical products. Medline will replace, at no charge, any electrosurgical products which fail to meet Medline’s standards of workmanship, materials or design, although Medline will not be responsible for damage after delivery due to accident, improper use or abuse, or failure to follow instructions provided by Medline. Included in this policy are electrosurgical generators, provided that any damage to such generators is proven to be solely caused by a defective Medline electrosurgical product or the incompatibility of the Medline product with the electrosurgical generator.

Indemnifi cation: Medline shall defend, hold harmless and indemnify the account for any and all losses, claims, judgments, and expenses (including but not limited to attorneys fees) relating to any claim of personal injury arising from or caused by any defect in the Medline electrosurgical product, provided that each of the following four conditions is satisfi ed:

(A) Such personal injury occurs during a surgical procedure in which the grounding pad is used in accordance with Medline’s instructions for use and only when used with an active accessory and electrosurgical generator with a functioning patient-contact monitoring system designed for use with a split style pad made by one of the following companies: Valleylab®, Conmed®, Aspen, Bard®, Birtcher, NDM, ERBE® and Bovie Medical.

(B) The personal injury is not caused by the account’s negligence or intentional misconduct, or as a result of a modifi cation to any of the machines, pads or cable.

(C) The Account notifi es Medline of the occurrence within a reasonable time thereafter, and has furnished prompt records of any and all claims of damage allegedly caused by defective Medline electrosurgical products, sent by registered or certifi ed mail addressed to Medline Offi ce of General Counsel, One Medline Place, Mundelein, IL 60060-4485.

(D) Medline controls the defense and resolution of any such claims, and the Account fully cooperates in such defense and resolution.

This agreement shall be valid and binding upon its execution by the account and Medline. This agreement constitutes the fi nal and complete agreement between the account and Medline and it terminates all prior written or oral agreements and understandings as to this agreement’s subject matter. Illinois law will apply in interpreting and enforcing this agreement.

Guarantee and Indemnifi cation Policy

support3

sup

po

rt

Page 44: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

1-800-MEDLINE | www.medline.com44

INDEX

Electrosurgical Grounding Pads

ITEM PAGE

9165 Split, Precorded 9

9165L Split, Precorded with 15' Cord 9

9160 Split, Non-Corded 9

9160F Split, Non-Corded, 5/pk 9

9130 Standard (Non-Split), Non-Corded 9

9130F Standard (Non-Split), Non-Corded, 5/pk 9

9135-LP Standard (Non-Split), Precorded 9

1149 Large (Non-Split) Pad, Non-Corded 9

1149C-LP Large (Non-Split) Pad, Precorded 9

1179 Large Split Pad, Precorded 9

1180 Large Split Pad, Non-Corded 9

1180F Large Split Pad, Non-Corded, 5/pk 9

1181 Small Split Pad, Precorded 9

Reusable Cables

21172 10' (3.05 m) Reusable Cable for Solid Pads 11

21174 10' (3.05 m) Reusable Cable for Split Pads 11

21174L 15' (4.57 m) Reusable Cable for Split Pads 11

21174ABC 10' (3.05 m) Reusable Cable for Argon Beam Coagulators 11

Electrosurgical Pencils

ESPB3000 Push Button, Blade Electrode 14

ESRK3000 Rocker Switch, Blade Electrode 14

ESRK3000L Rocker Switch, Blade Electrode, 15' cord 14

ESFS3000 Footswitch, Blade Electrode 14

ESPB3002 Push Button, PTFE Blade Electrode 15

ESRK3002 Rocker Switch, PTFE Blade Electrode 15

ESFS3002 Footswitch, Blade Electrode 15

ESRK3002L Rocker Switch, PTFE Blade Electrode, 15' cord 15

ESPB2000 Push Button, Blade Electrode 16

ESPBN2000 Push Button, Needle Electrode 16

ESRK2000 Rocker Switch, Blade Electrode 16

ESFS2000 Footswitch, Blade Electrode 16

Page 45: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

1-800-MEDLINE | www.medline.com 45

ind

ex

Electrosurgical Active Electrodes

ITEM PAGE

ES0012BL Blade Electrode, 2.5" (6.4 cm) 18

ES0012A Blade Electrode 2.75" (7 cm) 18

ES0012M Blade Electrode, Extended Insulation, 2.5" (6.4 cm) 18

ES0012AM Blade Electrode, Extended Insulation, 2.75" (7 cm) 18

ES0013 Needle Electrode, 2.75" (7 cm) 18

ES0013M Needle Electrode, Extended Insulation, 2.75" (7 cm) 18

ES0015 Ball Electrode, 0.06" (2 mm) Diameter, 2" Length (5 cm) 18

ES0014A Blade Electrode, 4" (10.2 cm) 19

ES0014AM Blade Electrode, Extended Insulation, 4" (10.2 cm) 19

ES0014 Blade Electrode, 6" (15.2 cm) 19

ES0014M Blade Electrode, Extended Insulation, 6" (15.2 cm) 19

ES0016 Needle Electrode, 6" (15.2 cm) 19

ES0016M Needle Electrode, Extended Insulation, 6" (15.2 cm) 19

ES0016AM Needle Electrode, Extended Insulation, 4" (10.2 cm) 19

ES0009 Ball Electrode, 0.19" (5 mm) Diameter, 5" Length (12.7 cm) 19

ESE1550 Ball Electrode, 0.19" (5 mm) Diameter, 2" Length 20

ESE1552 Needle Electrode, 2.84" (7.2 cm) 20

ESE155250 Needle Electrode, 2.84" (7.2 cm) 20

ESE1551X Blade Electrode, with Hex, 2.75" (7 cm) 20

ESE1551IX Blade Electrode, with Hex, Extended Insulation, 2.75" (7 cm) 20

ESE1552I Needle Electrode, Extended Insulation, 2.84" (7.2 cm) 20

ESE15516 Extended Blade Electrode, 6" (15.2 cm) 20

ESE15516IX Extended Blade Electrode, with Hex, Extended Insulation, 6.5" (16.5 cm) 20

ESE15526 Extended Needle Electrode, 6" (15.2 cm) 20

ESE1559 Tungsten Loop, 10 mm x 10 mm, 13 cm Length 21

ESE1560 Tungsten Loop, 15 mm x 12 mm, 13 cm Length 21

ESE1561 Tungsten Loop, 20 mm x 12 mm, 13 cm Length 21

ESE1562 Tungsten Loop, 20 mm x 15 mm, 13 cm Length 21

ESE1563 Stainless Steel Ball, 3 mm diameter, 13 cm Length 21

ESE1564 Stainless Steel Ball, 5 mm diameter, 13 cm Length 21

ESE1565 Tungsten Square, 5 mm x 5 mm, 13 cm Length 21

ESE1566 Tungsten Square, 10 mm x 4 mm, 13 cm Length 21

ESE1567 Tungsten Square Loop, 10 mm x 8 mm, 13 cm Length 21

ESE1510 Right Angle Hook Electrode, Insulated, with Safety Cap, 8.5" (21.6 cm) 22

Page 46: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

1-800-MEDLINE | www.medline.com46

INDEX

Electrosurgical Active Electrodes (continued)

ITEM PAGE

ESE1511 45° Angle Hook Electrode, Insulated, with Safety Cap, 8.5" (21.6 cm) 22

ESE1512 Angled Blade Electrode, Insulated, with Safety Cap, 8.5" (21.6 cm) 22

ESE1650 Tungsten Needle with Insulation, 2 cm Straight 22

ESE1651 Tungsten Needle with Insulation, 3 cm Straight 22

ESE277028 Straight Spatula Tip, 11" (28 cm) 23

ESE277128 Curved Spatula Tip, 11" (28 cm) 23

ESE277228 Wire J Hook Tip, 11" (28 cm) 23

ESE277328 Wire L Hook Tip, 11" (28 cm) 23

ESE277428 Flat L Hook Tip, 11" (28 cm) 23

Accessories

DYNJ01208 Cautery Tip Polisher, 2" x 2", (6 cm x 6 cm) 25

DYNJ01207 Disposable Bipolar Cord, Sterile 25

ESH1 Electrosurgical Safety Holster 25

Reusable Bipolar Forceps

MDS571004C Insulated, Straight Tip, 4.75" (12 cm) 27

MDS571104C Insulated, Angled Tip, 4.75" (12 cm) 27

MDS571204C Non-Insulated, Straight Tip, 4.75" (12 cm) 27

MDS571304C Non-Insulated, Angled Tip, 4.75" (12 cm) 27

MDS572004E Insulated, Straight Tip, 4.25" (10.7 cm) 27

MDS572104E Insulated, Angled Tip, 4.25" (10.7 cm) 27

MDS572204E Non-Insulated, Straight Tip, 4.25" (10.7 cm) 27

MDS572304E Non-Insulated, Angled Tip, 4.25" (10.7 cm) 27

MDS573004E Insulated, Straight Tip, 3.75" (9.5 cm) 27

MDS573104E Insulated, Angled Tip, 3.75" (9.5 cm) 27

MDS573204E Non-Insulated, Straight Tip, 3.75" (9.5 cm) 27

MDS573304E Non-Insulated, Angled Tip, 3.75" (9.5 cm) 27

MDS574004D Insulated, Straight Tip, 4.25" (10.7 cm) 28

MDS574104D Insulated, Angled Tip, 4.25" (10.7 cm) 28

MDS574204D Non-Insulated, Straight Tip, 4.25" (10.7 cm) 28

MDS574304D Non-Insulated, Angled Tip, 4.25" (10.7 cm) 28

MDS575104 Insulated, Angled Tip, 4.75" (12 cm) 28

Page 47: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

1-800-MEDLINE | www.medline.com 47

ind

ex

Reusable Bipolar Forceps (continued)

ITEM PAGE

MDS575304 Non-Insulated, Angled Tip, 4.75" (12 cm) 28

MDS587007 Insulated, Straight Tip, 6.25" (14 cm) 28

MDS587207 Non-Insulated, Straight Tip, 6.25" (14 cm) 28

MDS587008 Insulated, Straight Tip, 6.75" (17 cm) 28

MDS587208 Non-Insulated, Straight Tip, 6.75" (17 cm) 28

MDS589009E Insulated, Straight Tip, 6.75" (17 cm) 29

MDS589209E Non-Insulated, Straight Tip, 6.75" (17 cm) 29

MDS581006 Insulated, Straight Tip, 6.75" (17 cm) 29

MDS581106 Insulated, Angled Tip, 6.75" (17 cm) 29

MDS581206 Non-Insulated, Straight Tip, 6.75" (17 cm) 29

MDS581306 Non-Insulated, Angled Tip, 6.75" (17 cm) 29

MDS581007 Insulated, Straight Tip, 7.75" (19.7 cm) 29

MDS581107 Insulated, Angled Tip, 7.75" (19.7 cm) 29

MDS581207 Non-Insulated, Straight Tip, 7.75" (19.7 cm) 29

MDS581307 Non-Insulated, Angled Tip, 7.75" (19.7 cm) 29

MDS586006C Insulated, Straight Tip, 6.75" (15 cm) 29

MDS586206C Non-Insulated, Straight Tip, 6.75" (15 cm) 29

MDS586007C Insulated, Straight Tip, 7.75" (19.7 cm) 29

MDS586207C Non-Insulated, Straight Tip, 7.75" (19.7 cm) 29

MDS598007 Insulated, Straight Tip, 7.75" (19.7 cm) 30

MDS598107 Insulated, Angled Tip, 7.75" (19.7 cm) 30

MDS598207 Non-Insulated, Straight Tip, 7.75" (19.7 cm) 30

MDS598307 Non-Insulated, Angled Tip, 7.75" (19.7 cm) 30

MDS598008 Insulated, Straight Tip, 8.75" (22 cm) 30

MDS598108 Insulated, Angled Tip, 8.75" (22 cm) 30

MDS598208 Non-Insulated, Straight Tip, 8.75" (22 cm) 30

MDS598308 Non-Insulated, Angled Tip, 8.75" (22 cm) 30

MDS599008 Insulated, Straight Tip, 8.75" (22 cm) 30

MDS599208 Non-Insulated, Straight Tip, 8.75" (22 cm) 30

MDS599009 Insulated, Straight Tip, 9.75" (24.7 cm) 30

MDS599209 Non-Insulated, Straight Tip, 9.75" (24.7 cm) 30

MDS594007 Insulated, Straight Tip, 7.75" (19.7 cm) 31

MDS594207 Non-Insulated, Straight Tip, 7.75" (19.7 cm) 31

Page 48: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

1-800-MEDLINE | www.medline.com48

INDEX

Reusable Bipolar Forceps (continued)

ITEM PAGE

MDS594008 Insulated, Straight Tip, 8.75" (22 cm) 31

MDS594208 Non-Insulated, Straight Tip, 8.75" (22 cm) 31

MDS595006 Insulated, Straight Tip, 7" (17.8 cm) 31

MDS595206 Non-Insulated, Straight Tip, 7" (17.8 cm) 31

MDS595007 Insulated, Straight Tip, 8" (20.3 cm) 31

MDS595207 Non-Insulated, Straight Tip, 8" (20.3 cm) 31

MDS597008 Insulated, Straight Tip, 7.75" (19.7 cm) 32

MDS597108 Insulated, Angled Tip, 7.75" (19.7 cm) 32

MDS597208 Non-Insulated, Straight Tip, 7.75" (19.7 cm) 32

MDS597308 Non-Insulated, Angled Tip, 7.75" (19.7 cm) 32

MDS597009 Insulated, Straight Tip, 8.75" (22 cm) 32

MDS597109 Insulated, Angled Tip, 8.75" (22 cm) 32

MDS597209 Non-Insulated, Straight Tip, 8.75" (22 cm) 32

MDS597309 Non-Insulated, Angled Tip, 8.75" (22 cm) 32

MDS596006C Insulated, Straight Tip, 6.75" (17 cm) 32

MDS596206C Non-Insulated, Straight Tip, 6.75" (17 cm) 32

MDS596007C Insulated, Straight Tip, 7.75" (19.7 cm) 32

MDS596207C Non-Insulated, Straight Tip, 7.75" (19.7 cm) 32

MDS591007 Insulated, Straight Tip, 7.75" (19.7 cm) 33

MDS591107 Insulated, Angled Tip, 7.75" (19.7 cm) 33

MDS591207 Non-Insulated, Straight Tip, 7.75" (19.7 cm) 33

MDS591307 Non-Insulated, Angled Tip, 7.75" (19.7 cm) 33

MDS591008 Insulated, Straight Tip, 8.75" (22 cm) 33

MDS591108 Insulated, Angled Tip, 8.75" (22 cm) 33

MDS591208 Non-Insulated, Straight Tip, 8.75" (22 cm) 33

MDS591308 Non-Insulated, Angled Tip, 8.75" (22 cm) 33

MDS591010 Insulated, Straight Tip, 10.75" (27.3 cm) 33

MDS591110 Insulated, Angled Tip, 10.75" (27.3 cm) 33

MDS591210 Non-Insulated, Straight Tip, 10.75" (27.3 cm) 33

MDS591310 Non-Insulated, Angled Tip, 10.75" (27.3 cm) 33

MDS5990 Reusable Bipolar Cord, 10' (3 m) 33

Page 49: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

1-800-MEDLINE | www.medline.com 49

ind

ex

Bovie Smoke Evacuators and Accessories

ESUSMOKE Bovie Smoke Shark 40

ESUFILTER Smoke Evacuator 18-Hour Filter 40

ARN786TSBX Sterile Tubing 40

ARNSETWS Sterile Tubing with Wand 40

ESPB8000 Pencil, Push Button, Stainless Steel Tip, 1' Tubing 41

ESRK8000 Pencil, Rocker, Stainless Steel Tip, 1' Tubing 41

ESPB8002 Pencil, Push Button, PTFE Tip, 1' Tubing 41

ESRK8002 Pencil, Rocker, PTFE Tip, 1' Tubing 41

ESADPSM Adapter for Pencils, 1' Tubing 41

ESPB9000 Pencil, Push Button, Stainless Steel Tip, 10' Tubing 41

ESRK9000 Pencil, Rocker, Stainless Steel Tip, 10' Tubing 41

ESPB9002 Pencil, Push Button, PTFE Tip, 10' Tubing 41

ESRK9002 Pencil, Rocker, PTFE Tip, 10' Tubing 41

ESADP10 Adapter for Pencils, 10' Tubing 41

Bovie Generators

ITEM PAGE

ESUICONGP Electrosurgical Generator Icon GP 37

ESUFOOTICON Monopolar Footswitch for Icon GP 37

ESUFOOTGPB Bipolar Footswitch for Icon GP 37

ESUADAPTOR Adapter for Footswitch Accessories 37

ESUCARTGP Mobile Cart for Icon GP 37

ESUICONGPC Icon GP Generator Plus Cart and Accessories 37

ESUIDS300 IDS-300 Electrosurgical Generator (300w) 39

ESUIDS200 IDS-200 Electrosurgical Generator (200w) 39

ESUFOOTSWITCH Monopolar Footswitch for Bovie IDS 39

ESUFOOTSWICHB Bipolar Footswitch for Bovie IDS 39

ESUADAPTOR Adapter for Footswitch Accessories 39

ESUCART Mobile Cart for IDS generators 39

ESUIDS300C IDS-300 Generator Plus Cart and Accessories 39

ESUIDS200C IDS-200 Generator Plus cart and Accessories 39

Page 50: DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads

Medline United States1-800-MEDLINE (633-5463)www.medline.com [email protected]

Medline Canada1-800-396-6996www.medline.ca [email protected]

Medline México01-800-831-0898www.medlinemexico.com [email protected]

Medline Industries, Inc.One Medline PlaceMundelein, IL 60060

Some products may not be available for sale in Mexico or Canada. We reserve the right to correct any errors that may occur within this brochure. ©2011 Medline Industries, Inc. Medline and Blue Silk are registered trademarks of Medline Industries, Inc. Bovie is a registered trademark and BovieFDFS, BovieNEM, BovieFCFS, BovieDED, and Bovie Smoke Shark are trademarks of Bovie Medical Corporation. iPhone and Apple are registered trademarks of Apple Inc. Corporation. Tefl on is a registered trademark of E. I. du Pont de Nemours and Company. 3M and Micropore are trademarks of 3M Company. PenAdapt is a trademark of Buffalo Filter Corporation. Valleylab is a registered trademark of Covidien AG Corp., Conmed is a registered trademark of Conmed Corporation, Bard is a registered trademark of C. R. Bard, Inc., ERBE is a registered trademark of Erbe Elektromedizin GmbH. MKT211097 / LIT106 / 10M / SG / 22

ELECTROSURGERY ONLINE

➊ Download a QR Code reader app➋ Launch app➌ Hover the phone over this QR Code

MEDLINE UNIVERSITYYour source for clinical training and resources

FREE Continuing Education Join the thousands of nurses who log on to Medline

University every day to earn continuing education

credits on a wide variety of subjects.* Courses include

“Electrocautery Safety and OR Fire Prevention” and

“Electrosurgery Safety Considerations.” Over 50 courses!

New courses added every month.

Easy-to-use

Online, interactive courses

Downloadable podcasts (audio files)

Downloadable pdf documents

NEW! iPhone® apps available at The Apple® store

Informative

Video of today’s leading healthcare industry

experts sharing their insights on critical issues.

Online magazine articles from The OR Connection, Healthy Skin and Infection Prevention NowLinks to up-to-date healthcare news stories

*Courses approved for continuing education by the

Florida Board of Nursing and the California Board of

Registered Nursing

Get started today!Setting up an account at Medline University is as easy:

1. Go to www.medlineuniversity.com2. Select “Create Account” in top right corner3. Complete the brief online form to register

for your free account

and Healthy Skin

FREE Continuing EducationJoin the thousands of nurses who log on to MedlineUniversity every day to earn continuing educationcredits on a wide variety of subjects Courses include“Electrocautery Safety and OR Fire Prevention” and “Electrosurgery Safety Considerations.” Over 50 courses!New courses added every month.*

Online magazine articles from The OR Connection and Healthy Skin