DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC...
Transcript of DRIVEN BY SAFETY. FOCUSED ON QUALITY....meets IEC criteria for temperature rise (ANSI/ AAMI/IEC...
DRIVEN BY SAFETY. FOCUSED ON QUALITY.
1-800-MEDLINE | www.medline.com2
SAFETY. SELECTION. SUPPORT.
With Medline electrosurgical
products, you have it all: unique safety
features, a complete selection of high-
quality products and support that’s
second to none.
Throughout our offering of electrosurgical supplies,
you’ll fi nd unique features that provide safety for both
patients and clinicians.
The Universal Electrosurgical Grounding Pad is made
with the highest-quality 3M adhesives. The pad features a
proprietary Green Safety Ring with advanced technology
that reduces corner-and-edge effect and makes
placement much easier. Because of this technology, the
pad has a 33% smaller footprint and it can be orientated
in any direction.
Our complete selection of electrosurgical pencils
includes push-button, rocker-switch and foot-switch
confi gurations. And we carry a full line of stainless
steel and PTFE tips, including LLETZ Tungsten Loops,
laparoscopic tips and microsurgical Tungsten needles.
Bovie® Medical brand generators provide a consistent
clinical effect with the utmost safety, convenience and
fl exibility. Medline is proud to be a US distributor of
Bovie electrosurgical generators.
Medline not only warranties our own electrosurgical
generators but those of our competitors as well, at no
charge, provided they’re less than eight years old. We
offer the longest service plan in the industry, with
up to eight years of coverage. All our products are fully
guaranteed, and we indemnify our customers against any
and all losses.*
*Conditions apply. See page 43 for our Guarantee and Indemnifi cation policies.
padspencils
electrodesaccessories
forcepsgenerators
support1-800-MEDLINE | www.medline.com 3
4 . . . . . . . . GROUNDING PADS
8 . . . . . . . .Universal Electrosurgical Pad with Safety Ring (9100 Series) 9 . . . . . . . . .Electrosurgical Grounding Pads (1100 Series)10 . . . . . . . . .Reusable Cables (21100 Series)
12 . . . . . . . . .ELECTROSURGICAL PENCILS
14 . . . . . . . . .Vega Series15 . . . . . . . . .Vega Series with Blue Silk® PTFE Non-Stick Coated Tips16 . . . . . . . . .Cygnus Series
17. . . . . . . . . ELECTROSURGICAL ACTIVE ELECTRODES (TIPS)
18 . . . . . . . . .Blue Silk® PTFE Non-Stick Coated Electrodes 20 . . . . . . . . .Stainless Steel Electrodes21 . . . . . . . . .Lletz Tungsten Loop Electrodes22 . . . . . . . . .Arthroscopic Electrodes22 . . . . . . . . .Microsurgical Tungsten Needles23. . . . . . . . . Laparoscopic Electrodes
24. . . . . . . . . ACCESSORIES
25 . . . . . . . . .Electrosurgical Tip Cleaner25 . . . . . . . . .Bipolar Cord25 . . . . . . . . .Electrosurgical Safety Holster
26. . . . . . . . . REUSABLE BIPOLAR FORCEPS
27 . . . . . . . . .Straight Bipolar Forceps 30 . . . . . . . . .Bayonet Bipolar Forceps 33 . . . . . . . . .Reusable Accessories
34. . . . . . . . . B OVIE® GENERATORS AND SMOKE EVACUATORS
36 . . . . . . . . .Bovie Icon GP Electrosurgical Generator38 . . . . . . . . .Bovie IDS Electrosurgical Generators40 . . . . . . . . .Bovie Smoke Evacuator41 . . . . . . . . .Smoke Evacuator Accessories
42. . . . . . . . . SERVICE AND SUPPORT
44. . . . . . . . . INDEX
TABLE OF CONTENTS
cross referencepads
supportoss reference
supportsupport
crocc
padspencils
electrodesaccessories
forcepsgenerators
support
1-800-MEDLINE | www.medline.com4
The Medline Universal Electrosurgical
Grounding Pad 9100 Series (manufactured
by 3MTM) is a breakthrough in electrosurgical pad
technology. This pad is smaller in size – a mere 15
square inches – so it’s very easy to place, and it
meets the same thermal performance standards
as traditional pads with a 33% larger conductive
surface area. This Safety Ring technology is only
available on Medline universal grounding pads.
GROUNDING PADS
5 … UNIVERSAL ELECTROSURGICAL PAD
WITH SAFETY RING (9100 SERIES)
8 … ELECTROSURGICAL GROUNDING PADS
(1100 SERIES)
9 … REUSABLE CABLES (21100 SERIES)
padspencils
electrodesaccessories
forcepsgenerators
support1-800-MEDLINE | www.medline.com 5
Universal Electrosurgical Pad with Safety Ring (9100 Series)
padsp
ads
THE SOLUTION TO AN OLD PROBLEM
The tendency for electrosurgical current and heat to cluster at the leading edge of a non-capacitive pad has been a long-standing, industry-wide design concern. Because of this clustering (known as “corner and edge effect"), safety considerations have dictated that pads should be placed with the long edge perpendicular to the surgical site.
Uniform dispersion of current
Current clusters at leading edge and corners
Universal Electrosurgical Pad with Safety Ring
The revolutionary green Safety Ring provides Medline’s pad with greater effi ciency and reduced corner and edge effect, thereby allowing for smaller size and universal orientation.
PROPRIETARY SAFETY RING ALLOWS FOR UNIVERSAL ORIENTATION AND CONVENIENCE
Traditional Design
1-800-MEDLINE | www.medline.com6 1-1 80800-0 MEMEDLDLININEE || wwwwww.memedldlininee.cocomm66
Medline’s Universal Electrosurgical Pad, with our revolutionary, patented Green Safety Ring.
• Same Performance in a Smaller SizeThe Medline Universal Electrosurgical Pad meets IEC criteria for temperature rise (ANSI/AAMI/IEC 60601-2-2:2009, Medical electrical equipment—Part 2-2), similar to traditional pads that are 33% larger.
• More Evenly Distributed Current With the Medline pad, current is reduced at the corners and the leading edge. This more uniform dispersion reduces “corner and edge effect,” while meeting the same thermal performance standards as pads with a 33% larger conductive surface area.
• Cost-EffectiveStandardizing with the Medline Universal Pad can help you eliminate SKUs. Infant pads may no longer be necessary as the Medline pads have no minimum age or weight requirement, as long as the pad makes full contact with the patient – without overlap – at a suitable placement site.
• Three-Year Shelf LifeThe Medline pad’s long shelf life helps improve inventory management effi ciency.
• Latex Free No natural rubber latex or dry natural rubber is used in 9100 Series Electrosurgical Pads or their packaging.
• Broad CompatibilityThe Medline Universal Pad with Safety Ring is compatible with all electrosurgical generators (ESUs) used in surgical procedures, as defi ned by the ANSI/AAMI Standard HF18:2001, Electrosurgical Devices.
Stress Flaps The tab end of the plate is securely held onto the patient with stress fl aps, minimizing the chance of dislodging if the cable or cord is inadvertently pulled.
Easy to Place
Smaller size allows the pad to be oriented in any direction at a suitable placement site.
GROUNDING PADS
padspencils
electrodesaccessories
forcepsgenerators
support1-800-MEDLINE | www.medline.com 7
Transthermal Backing Permits Heat to Escape Faster.
Older grounding pads use a foam backing material, which locks in heat. Medline’s Universal Pads use a transthermal backing, similar to surgical drape material, which lets heat escape 25% faster than foam and reduces the risk of unsafe temperature rise.
Fluid-Resistant Backing
Similar to surgical drapes, the Medline pads feature a nonwoven backing with a thick (3 mil) layer of polyethylene, forming a waterproof, fl uid-resistant moisture barrier.
Non-Conductive Isolation Border
To help seal out unwanted fl uids, the conductive adhesive gel is surrounded by a non-conductive isolation border. The pad’s border adhesive is similar in properties to 3M’s popular Micropore™ tape.
Helps Reduce Chance of Skin Stripping
For patients with fragile skin, our non-aggressive border adhesive reduces the possibility of skin stripping.
Excellent Pad-To-Skin Contact
Water-based hydrophilic conductive adhesive fl ows uniformly into skin crevices, providing exceptional pad-to-skin contact.
padsp
ads
R-Value* for Backing
Blue Foam
Backing
Universal PadTransthermal Backing *R-Value is a material’s resistance to heat transmission.
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
1-800-MEDLINE | www.medline.com8
GROUNDING PADS
Electrosurgical Grounding Pads (1100 Series)Low-impedance connection with minimal skin irritation and skin trauma. The 1100 Series grounding pads have a soft, gel-like conductive adhesive surrounded by an isolation border on a white foam backing. Item nos.1149, 1149C-LP, 1179 and 1180 have a conductor area of approximately 20 square inches. Our Small Split Pad (item no. 1181) has a conductor area of approximately 10 square inches and is intended for use when a larger pad is too big to use at the recommended placement site.
• Lightweight, conformable foam backing (white)
• Stress fl aps to secure the tab end of the pad
• Exceptional pad-to-skin contact from 3M’s gel-like, water-based (hydrophilic) conductive adhesive
• Non-conductive border adhesive
Available in Split and Solid Styles, With or Without Pre-Attached Cords
An electrosurgical pad should be placed on a well-vascularized muscular surface. However, the traditional 20 square-inch pads can be difficult to place, making the Medline Universal Pad with Safety Ring an excellent choice.
Large pads are difficult to place on patients who are:
• Small in size and weight• Emaciated• Elderly• Lacking in muscle tissue• Afflicted with a skin malady• Suffering from burns over a signifi cant
percentage of the body
Availability of sites for the placement of electrosurgical pads is reduced by the presence of:
• Scar tissue• Bony prominences• Implants• Pacemakers• Excessive hair• Weight bearing sites• Burns over a signifi cant percentage of the body• A skin surface where fl uid might pool
Additional benefi ts of the smaller size of the Medline Universal Pad include:
• More convenient handling• Less area on patient to prep• A greater number of suitable placement sites
The small size, shape and thin – but tough – construction of the Medline Universal Pad 9100 Series encourages optimum use by eliminating the need for compromise on pad application sites. Since only a small area is needed for application, this pad will fi t a greater number of suitable sites on the patient’s body.
SAFE ELECTROSURGICAL PAD PLACEMENT CAN BE A CHALLENGE. THE MEDLINE UNIVERSAL PAD WITH SAFETY RING IS THE SOLUTION.
padspencils
electrodesaccessories
forcepsgenerators
support1-800-MEDLINE | www.medline.com 9
padsp
ads
1179 1180 1149 1149C-LP 1181
1100 SeriesITEM # DESCRIPTION CONDUCTIVE
ADHESIVE AREA PACKAGE
1149 Large (Non-Split) Pad, Non-Corded 20 sq. inches (129 sq. cm) 1/pouch, 100/cs
1149C-LP Large (Non-Split) Pad, Precorded with Large Plug 20 sq. inches (129 sq. cm) 1/pouch, 40/cs
1179 Large Split Pad, Precorded 20 sq. inches (129 sq. cm) 1/pouch, 40/cs1180 Large Split Pad, Non-Corded 20 sq. inches (129 sq. cm) 1/pouch, 100/cs1180F Large Split Pad, Non-Corded 20 sq. inches (129 sq. cm) 5/pouch, 200/cs1181 Small Split Pad, Precorded 10 sq. inches (64.5 sq. cm) 1/pouch, 40/cs
9100 SeriesITEM # DESCRIPTION CONDUCTIVE
ADHESIVE AREA PACKAGE
9165 Split, Precorded 15 sq. in. (97 sq. cm) 1/pouch, 40/cs9165L Split, Precorded with 15' Cord 15 sq. in. (97 sq. cm) 1/pouch, 40/cs9160 Split, Non-Corded 15 sq. in. (97 sq. cm) 1/pouch, 100/cs9160F Split, Non-Corded 15 sq. in. (97 sq. cm) 5/pouch, 200/cs9130 Standard (Non-Split), Non-Corded 15 sq. in. (97 sq. cm) 1/pouch, 100/cs9130F Standard (Non-Split), Non-Corded 15 sq. in. (97 sq. cm) 5/pouch, 200/cs
9135-LP Standard (Non-Split), Precorded with Large Plug 15 sq. in. (97 sq. cm) 1/pouch, 40/cs
9165 9160 9130 9135-LP
1-800-MEDLINE | www.medline.com10
GROUNDING PADS
• Dollar savings Hospitals pay as much as 40% more for electrosurgical pads with pre-attached cords than for pads without pre-attached cords. Hospitals can enjoy considerable savings with multiple-use cables and non-corded pads.
• CompatibleThe 21100 line of cables and clamps is compatible with virtually all electrosurgical generators.
• AAMI standardsThe 21100 Series multiple-use cables and clamps meet standards set by the Association of the Advancement of Medical Instrumentation for Electrosurgical Devices, cables and accessories (ANSI/AAMI HF18:2001).
• Latex indicationNeither natural rubber latex nor dry natural rubber are components in 21100 Series multiple use cables and clamps or their packaging.
• ConvenientThe 21100 Series cables and clamps have chemical resistance and can be cleaned easily after use with a wide variety of cleaning materials. They can be exposed to the ETO sterilization process but must be aerated for 16 hours after ETO sterilization.
• Reduces potential for skin trauma The low profi le and smooth clamp assembly of the 21100 Series decreases the likelihood of skin trauma.
• Extra-strong holding forceThe 21100 Series clamp employs the “torturous path" concept in its design giving it a holding force that is secure and safe.
• Long life The strong design and materials used make the 21100 Series heavy duty and impact resistant.
Use of multiple-use cables means miles of copper wire will not become waste. And there is no PVC in 21100 Series multiple-use cables and clamps.
Multiple-use Cables
padspencils
electrodesaccessories
forcepsgenerators
support1-800-MEDLINE | www.medline.com 11
ITEM # DESCRIPTION FOR USE WITH UNI-VERSAL 9100 SERIES
FOR USE WITH 1100 SERIES PLATES
PACKAGE
21172 10' (3.05 m) Reusable Cable for Solid Pads 9130, 9130F 1149, 1149F each
21174 10' (3.05 m) Reusable Cable for Split Pads 9160, 9160F 1180, 1180F each
21174L 15' (4.57 m) Reusable Cable for Split Pads 9160, 9160F 1180, 1180F each
21174ABC10' (3.05 m) Reusable Cable for Argon Beam Coagulators
9160, 9160F 1180, 1180F each
21100 Series
padsp
ads
Medline Reusable Cables (21100 Series)
21174
21174 shown with split pad attached
Choose from sterile pencils in pushbutton,
rockerswitch and footswitch confi gurations.
Every pencil is packaged with a holster to help
promote AORN recommended practices.* Medline
also offers a pencil with a PTFE tip already attached;
this increases efficiency and eliminates waste as
non-stick tips no longer need to be pulled separately,
eliminating the cost of the stainless steel blade.
*Blanchard J, Burlingame B, eds. Perioperative Standards and Recommended Practices. AORN; 2011.
14 … VEGA SERIES
16 … CYGNUS SERIES
1-800-MEDLINE | www.medline.com12
ELECTROSURGICAL PENCILS
padspencils
electrodesaccessories
forcepsgenerators
support1-800-MEDLINE | www.medline.com 13
Electrosurgical Pencils Designed exclusively for surgeons who prefer a more traditional feel, these pencils feature tactile buttons, less memory in the cords and high-quality plugs.
One piece NOSE
Nickel-plated PINS
Soft, fl exible CORD
Double-molded PLUG
Soft BUTTONS
pencilsp
encils
1-800-MEDLINE | www.medline.com14
Standard Stainless Steel Tip, Sterile
ITEM # DESCRIPTION PACKAGE
ESPB3000 Push Button, Blade Electrode 50/cs
ESRK3000 Rocker Switch, Blade Electrode 50/cs
ESRK3000L Rocker Switch, Blade Electrode 15’ cord 50/cs
ESFS3000 Footswitch, Blade Electrode 50/cs
ESPB3000
ESRK3000
ESFS3000
Vega Series with Standard Stainless Steel Tip
• For most standard 2.4 mm (3/32 in.) shaft electrodes
• Manufactured to the highest quality standards in compliance with IEC Electrical Safety Standard 60601-2-2
• Fully guaranteed (see page 43 for Guarantee and Indemnifi cation Policy)
• Sterile and individually packaged with a safety holster
ELECTROSURGICAL PENCILS
padspencils
electrodesaccessories
forcepsgenerators
support1-800-MEDLINE | www.medline.com 15
NON-STICK PERFORMANCE
• Allows the electrodes to be easily cleaned with a wet piece of gauze or sponge instead of an abrasive scratch pad
• Rounded edges prevent RF current from concentrating too much energy in one area
• All tips less than 3" in length feature ribbed insulation allowing for easy tip changes, even under wet conditions
Vega Series with Blue Silk® Non-Stick PTFE-Coated Tip Coated with PTFE, the Same Non-Stick Compound Used in Tefl on®
Blue Silk® PTFE Non-Stick Coated Tip, Sterile
ITEM # DESCRIPTION PACKAGE
ESPB3002 Push Button, Blue Silk, Non-Stick Blade 50/cs
ESRK3002 Rocker Switch, Blue Silk, Non-Stick Blade 50/cs
ESRK3002L Rocker Switch, Blade Electrode 15’ cord 50/cs
ESFS3002 Footswitch, Blue Silk, Non-Stick Blade 50/cs
ESPB3002
ESRK3002
ESFS3002
pencilsp
encils
1-800-MEDLINE | www.medline.com16
Standard Stainless Steel Tip, Sterile
ITEM # DESCRIPTION PACKAGE
ESPB2000 Push Button, Blade Electrode 50/cs
ESPBN2000 Push Button, Needle Electrode 50/cs
ESRK2000 Rocker Switch, Blade Electrode 50/cs
ESFS2000 Foot Switch, Blade Electrode 50/cs
Cygnus Series with Standard Stainless Steel Tip
• The same great features as our Vega Series with a slightly different-shaped housing
• For most standard 2.4 mm (3/32 in.) shaft electrodes
• Manufactured to the highest quality standards in compliance with IEC Electrical Safety Standard 60601-2-2
• Fully guaranteed (see page 43 for Guarantee and Indemnity)
• Sterile and individually packaged with a safety holster
ESFS2000
ELECTROSURGICAL PENCILS
ESPBN2000
ESPB2000
ESRK2000
padspencils
electrodesaccessories
forcepsgenerators
support1-800-MEDLINE | www.medline.com 171-1-80800-0-MMEMEDLDLINE | www.medline.co
High-quality active electrodes manufactured
to exacting tolerances. All tips under 3" have
ribbed insulation for easy tip changes, even under
wet conditions. Choose from a complete selection
of active electrodes. The standard 2.4 mm (0.09")
shafts fi t most electrosurgical pencils.
ELECTROSURGICAL ACTIVE ELECTRODES (TIPS)
18 … BLUE SILK® NON-STICK
PTFE-COATED ELECTRODES
20 … STAINLESS STEEL ELECTRODES
21 … LLETZ TUNGSTEN LOOP ELECTRODES
22 … ARTHROSCOPIC ELECTRODES
22 … MICROSURGICAL TUNGSTEN NEEDLES
23 … LAPAROSCOPIC INSTRUMENTS
17
padssupport
foorcrcepepssssssggegegeneneneeeerrarararararaattotototorsrsrs
117
padspencils
electrodesaccessories
forcepsgenerators
supportelectrodes
electrod
es
1-800-MEDLINE | www.medline.com18
Coated with PTFE, the Same Non-Stick Compound Used in Tefl on®
• Standard 2.4 mm (3/32 in.) shaft designed to fi t most electrosurgical pencils
• Easily cleaned with a wet piece of gauze or sponge (as opposed to an abrasive scratch pad)
• Rounded blade edges prevent RF current from concentrating too much energy in one area
• Ribbed insulation for easy tip changes, even under wet conditions
Ribbed INSULATION
Rounded BLADE
Blue Silk® Non-Stick PTFE-Coated Electrodes, Single Use, Sterile
ITEM # DESCRIPTION PACKAGE
ES0012BL Blade Electrode, 2.5" (6.4 cm) 12/bx
ES0012A Blade Electrode 2.75" (7 cm) 12/bx
ES0012M Blade Electrode, Extended Insulation, 2.5" (6.4 cm) 12/bx
ES0012AM Blade Electrode, Extended Insulation, 2.75" (7 cm) 12/bx
ES0013 Needle Electrode, 2.75" (7 cm) 12/bx
ES0013M Needle Electrode, Extended Insulation, 2.75" (7 cm) 12/bx
ES0015 Ball Electrode, 0.06" (2 mm) Diameter, 2" Length (5.1 cm) 12/bx
ES0013
ES0012BLL
ES0012A
ES0012M
ES0012AM
ES0015
ES0013M
ELECTROSURGICAL ACTIVE ELECTRODES (TIPS)
Blue Silk® Non-Stick PTFE-Coated Electrodes, Single Use, Sterile
padspencils
electrodesaccessories
forcepsgenerators
support1-800-MEDLINE | www.medline.com 19
NON-STICK PERFORMANCE
electrodeselectro
des
Blue Silk® Non-Stick PTFE-Coated Electrodes, Single Use, Sterile
ES0014AM
ES0014
ES0016AM
ES0014M
ES0016
ES0016MM
M
ES0009
Blue Silk® Non-Stick PTFE-Coated Electrodes, Single Use, Sterile
ITEM # DESCRIPTION PACKAGE
ES0014A Blade Electrode, 4" (10.16 cm) 12/bx
ES0014AM, Blade Electrode, Extended Insulation, 4" (10.16 cm) 12/bx
ES0014 Blade Electrode, 6” (15.24 cm) 12/bx
ES0014M Blade Electrode, Extended Insulation, 6” (15.24 cm) 12/bx
ES0016 Needle Electrode, 6” (15.24 cm) 12/bx
ES0016M Needle Electrode, Extended Insulation, 6” (15.24 cm) 12/bx
ES0016AM Needle Electrode, Extended Insulation, 4" (10.16 cm) 12/bx
ES0009 Ball Electrode, 0.19" (5 mm) Diameter, 5" Length (12.7 cm) 12/bx
ES0014A
1-800-MEDLINE | www.medline.com20
Stainless Steel Electrodes, Single Use, Sterile
Standard 2.4 mm (3/32") Shaft, Designed to Fit Most Electrosurgical Pencils
Stainless Steel Electrodes, Single Use, Sterile
ITEM # DESCRIPTION PACKAGE
ESE1550 Ball Electrode, 0.19" (5 mm) Diameter, 2" Length 150/cs
ESE1552 Needle Electrode, 2.84" (7.2 cm) 150/cs
ESE155250 Needle Electrode, 2.84" (7.2 cm) 50/cs
ESE1551X Blade Electrode, with Hex, 2.75" (7 cm) 150/cs
ESE1551IX Blade Electrode, with Hex, Extended Insulation, 2.75" (7 cm) 150/cs
ESE1552I Needle Electrode, Extended Insulation, 2.84" (7.2 cm) 50/cs
ESE15516 Extended Blade Electrode, 6" (15.2 cm) 50/cs
ESE15516IX Extended Blade Electrode, with Hex, Extended Insulation, 6.5" (16.5 cm) 50/cs
ESE15526 Extended Needle Electrode, 6" (15.2 cm) 50/cs
ELECTROSURGICAL ACTIVE ELECTRODES (TIPS)
ESE155265526
ESE15516
ESE1550SEE1550
ESE1552
ESE1551X
ESE1552I
ESE1551IX
ESE1556IX
SE155526
6
ESEE1552I1552I
56IX
padspencils
electrodesaccessories
forcepsgenerators
support1-800-MEDLINE | www.medline.com 21
Lletz Tungsten Loop Electrodes, Single Use, Sterile
ITEM # DESCRIPTION PACKAGE
ESE1559 Tungsten Loop, 10 mm x 10 mm, 13 cm Length 10/cs
ESE1560 Tungsten Loop, 15 mm x 12 mm, 13 cm Length 10/cs
ESE1561 Tungsten Loop, 20 mm x 12 mm, 13 cm Length 10/cs
ESE1562 Tungsten Loop, 20 mm x 15 mm, 13 cm Length 10/cs
ESE1563 Stainless Steel Ball, 3 mm diameter, 13 cm Length 10/cs
ESE1564 Stainless Steel Ball, 5 mm diameter, 13 cm Length 10/cs
ESE1565 Tungsten Square, 5 mm x 5 mm, 13 cm Length 10/cs
ESE1566 Tungsten Square, 10 mm x 4 mm, 13 cm Length 10/cs
ESE1567 Tungsten Square Loop, 10 mm x 8 mm, 13 cm Length 10/cs
Lletz Tungsten Loop Electrodes, Single Use, Sterile
Standard 2.4 mm (3/32") Shaft, Designed to Fit Most Electrosurgical Pencils
ESE1560
ESE1561
SE1560SE1560
ESE1561
ESE1562
Standard 2.4 mm (3/32") Shaft, Designed to Fit Most Electr
ESE1559
ESE1564
ESE1563
64
ESE156565
ESE1566566
ESE1567
electrodeselectro
des
1-800-MEDLINE | www.medline.com22
ELECTROSURGICAL ACTIVE ELECTRODES (TIPS)
Arthroscopic Electrodes, Single Use, SterileStandard 2.4 mm (3/32") Shaft, Designed to Fit Most Electrosurgical Pencils
copic Electrodes,
ESE151015
ESE1511
ESE1512
10
1511
SE1512
Arthroscopic Electrodes, Single Use, Sterile
ITEM # DESCRIPTION PACKAGE
ESE1510 Right Angle Hook Electrode, Insulated, with Safety Cap, 8.5" (21.6 cm) 10/cs
ESE1511 45° Angle Hook Electrode, Insulated, with Safety Cap, 8.5" (21.6 cm) 10/cs
ESE1512 Angled Blade Electrode, Insulated, with Safety Cap, 8.5" (21.6 cm) 10/cs
Microsurgical Tungsten Needles, Single Use, SterileStandard 2.4 mm (3/32") Shaft, Designed to Fit Most Electrosurgical Pencils
ESE1650
ESE1651
Microsurgical Tungsten Needles, Single Use, Sterile
ITEM # DESCRIPTION PACKAGE
ESE1650 Tungsten Needle with Insulation, 2 cm Straight 10/cs
ESE1651 Tungsten Needle with Insulation, 3 cm Straight 10/cs
padspencils
electrodesaccessories
forcepsgenerators
support1-800-MEDLINE | www.medline.com 23
electrodeselectro
des
Solid Laparoscopic Electrodes, Single Use, SterileStandard 2.4 mm (3/32") Shaft, Designed to Fit Laparoscopic Hand Units – Electrodes Fit 5 mm Trocar Cannulas
ESE277428
ESE277328
ESE277228
ESE277128
ESE277028
Lletz Tungsten Loop Electrodes, Single Use, Sterile
ITEM # DESCRIPTION PACKAGE
ESE277028 Straight Spatula Tip, 11" (28 cm) 10/cs
ESE277128 Curved Spatula Tip, 11" (28 cm) 10/cs
ESE277228 Wire J Hook Tip, 11" (28 cm) 10/cs
ESE277328 Wire L Hook Tip, 11" (28 cm) 10/cs
ESE277428 Flat L Hook Tip, 11" (28 cm) 10/cs
24
Electrosurgical accessories, such as tip cleaners
and bipolar cords, can be as vital to a procedure
as your Bovie generator. Safety holsters for holding
cautery pencils when not in use (available separately)
are recommended by the AORN and can be invaluable
in helping to protect your patients and staff.* To ensure
that you never run out of any electrosurgical product,
you need a supplier who offers quick turnaround
times and outstanding service. Medline maintains 32
distribution centers, strategically located throughout the
US, with over 8 million square feet of product storage.
With such vast resources, Medline can deliver the
products you need, when you need them.
*Blanchard J, Burlingame B, eds. Perioperative Standards and Recommended Practices. AORN; 2011.
ACCESSORIES
AORN and can be invaluable
tect your patients and staff.* To ensure
never run out of any electrosurgical product,
u need a supplier who offers quick turnaround
times and outstanding service. Medline maintains 32
distribution centers, strategically located throughout the
US, with over 8 million square feet of product storaagege.
With such vast resources, Medline can deliveveeerr rrrr tthttthththtthththhheeee e e
products you need, when you need thehem.
*Blanchard J, Burlingame B, eds. Perioperaeratitive SStatandararrddds ds anddddndd Recommended Practices. AORN; 201111.
1-800-MEDLINE | www.medline.com
padspencils
electrodesaccessories
forcepsgenerators
support1-800-MEDLINE | www.medline.com 25
padspencils
generatorssupport
padspencils
electrodesaccessories
forcepsgenerators
support
Electrosurgical Tip Cleaner• For quick-and-easy cleaning of
cautery tips during surgery
• Radiopaque
• Sturdy adhesive backing can be secured anywhere with ease
Electrosurgical Tip Cleaner, Sterile
ITEM # DESCRIPTION PACKAGE
DYNJ01208 Cautery Tip Polisher, 2" x 2" (5 cm x 5 cm) 100/cs
Electrosurgical Safety Holster• For placement of pencils when not in use
• Sturdy, non-conductive plastic
• Large clip for easy attachment to drape or stand
Electrosurgical Safety Holster
ITEM # DESCRIPTION PACKAGE
ESH1 Electrosurgical Safety Holster 30/cs
Bipolar Cord • Manufactured with the highest grade
of insulating materials available
• 12’ in length
• Fit all standard forceps
Bipolar Cord
ITEM # DESCRIPTION PACKAGE
DYNJ01207 Disposable Bipolar Cord, Sterile 50/cs
accessoriesaccesso
ries
1-800-MEDLINE | www.medline.com26 1-800-MEDLINE | www.medline.com26 ne com
Bipolar forceps play an important role in
precise hemostasis. Medline’s high-quality
bipolar forceps are reusable and fully autoclavable,
helping you control and reduce surgical procedure
costs. Choose from the following selection of
forceps for use across all surgical procedures.
REUSABLE BIPOLAR FORCEPS
27 … STRAIGHT BIPOLAR FORCEPS
30 … BAYONET BIPOLAR FORCEPS
33 … REUSABLE ACCESSORIES
padspencils
electrodesaccessories
forcepsgenerators
support1-800-MEDLINE | www.medline.com 27
Straight Bipolar Forceps – Footswitching, 2-Pin Connection Special Micro and Ophthalmic Bipolar Forceps
Adson
ITEM # SIZE DESCRIPTION PACKAGE
MDS571004C 4.75" (12 cm) Insulated, Straight Tip each
MDS571104C 4.75" (12 cm) Insulated, Angled Tip each
MDS571204C 4.75" (12 cm) Non-Insulated, Straight Tip each
MDS571304C 4.75" (12 cm) Non-Insulated, Angled Tip each
* Please note: items are only available with a 1.0 mm tip.
Jewelers
ITEM # SIZE DESCRIPTION PACKAGE
MDS572004E 4.25" (10.7 cm) Insulated, Straight Tip each
MDS572104E 4.25" (10.7 cm) Insulated, Angled Tip each
MDS572204E 4.25" (10.7 cm) Non-Insulated, Straight Tip each
MDS572304E 4.25" (10.7 cm) Non-Insulated, Angled Tip each
Please note: items are only available with a needle tip.
Iris
ITEM # SIZE DESCRIPTION PACKAGE
MDS573004E 3.75" (9.5 cm) Insulated, Straight Tip each
MDS573104E 3.75" (9.5 cm) Insulated, Angled Tip each
MDS573204E 3.75" (9.5 cm) Non-Insulated, Straight Tip each
MDS573304E 3.75" (9.5 cm) Non-Insulated, Angled Tip each
Please note: items are only available with a needle tip.
MDS572004E
MDS573004
MDS571005D
forcepsfo
rceps
More lengths available —ask your Medline representative.
TIP SIZE SPECIFICATIONS
B1.5 mm
A2.0 mm
ENEEDLE
D0.5 mm
C1.0 mm
1-800-MEDLINE | www.medline.com28
REUSABLE BIPOLAR FORCEPS
McPherson
ITEM # SIZE DESCRIPTION PACKAGE
MDS574004D 4.25" (10.7 cm) Insulated, Straight Tip each
MDS574104D 4.25" (10.7 cm) Insulated, Angled Tip each
MDS574204D 4.25" (10.7 cm) Non-Insulated, Straight Tip each
MDS574304D 4.25" (10.7 cm) Non-Insulated, Angled Tip each
Please note: items are only available with a 0.5 mm tip.
Coaptation
ITEM # SIZE DESCRIPTION PACKAGE
MDS575104* 4.75" (12 cm) Insulated, Angled Tip each
MDS575304* 4.75" (12 cm) Non-Insulated, Angled Tip each
* To select your tip, add “D” for 0.5 mm or “E” for needle to the end of the item number.
FPO
Special Micro and Ophthalmic Bipolar Forceps
Straight Bipolar Forceps – Footswitching, 2-Pin Connection
More lengths available — ask your Medline representative.
Malis
ITEM # SIZE DESCRIPTION PACKAGE
MDS587007* 6.25" (16 cm) Insulated, Straight Tip each
MDS587207* 6.25" (16 cm) Non-Insulated, Straight Tip each
MDS587008 6.75" (17 cm) Insulated, Straight Tip each
MDS587208 6.75" (17 cm) Non-Insulated, Straight Tip each
* To select your tip, add “D” for 0.5 mm, or “E” for needle to the end of the item number.
MDS575304
MDS574204D
y
TION PAC
MDS587007
padspencils
electrodesaccessories
forcepsgenerators
support1-800-MEDLINE | www.medline.com 29
Cushing
ITEM # SIZE DESCRIPTION PACKAGE
MDS581006* 6.75" (17 cm) Insulated, Straight Tip each
MDS581106* 6.75" (17 cm) Insulated, Angled Tip each
MDS581206* 6.75" (17 cm) Non-Insulated, Straight Tip each
MDS581306* 6.75" (17 cm) Non-Insulated, Angled Tip each
MDS581007* 7.75" (19.7 cm) Insulated, Straight Tip each
MDS581107* 7.75" (19.7 cm) Insulated, Angled Tip each
MDS581207* 7.75" (19.7 cm) Non-Insulated, Straight Tip each
MDS581307* 7.75" (19.7 cm) Non-Insulated, Angled Tip each
* T o select your tip, add “A” for 2.0 mm, “B” for 1.5 mm, “C” for 1.0 mm, “D” for 0.5 mm, or “E” for needle to the end of the item number.
Gerald
ITEM # SIZE DESCRIPTION PACKAGE
MDS586006C 6.75" (17 cm) Insulated, Straight Tip each
MDS586206C 6.75" (17 cm) Non-Insulated, Straight Tip each
MDS586007C 7.75" (19.7 cm) Insulated, Straight Tip each
MDS586207C 7.75" (19.7 cm) Non-Insulated, Straight Tip each
Please note: items are only available with a 1.0 mm tip.
FPO
Semkin
ITEM # SIZE DESCRIPTION PACKAGE
MDS589009E 6.75" (17 cm) Insulated, Straight Tip each
MDS589209E 6.75" (17 cm) Non-Insulated, Straight Tip each
Please note: items are only available with a needle tip.
MDS586007C
MDS581007
MDS589006E
forcepsfo
rceps
More lengths available —ask your Medline representative.
TIP SIZE SPECIFICATIONS
B1.5 mm
A2.0 mm
ENEEDLE
D0.5 mm
C1.0 mm
1-800-MEDLINE | www.medline.com30
REUSABLE BIPOLAR FORCEPS
More lengths available — ask your Medline representative.
Rhoton
ITEM # SIZE DESCRIPTION PACKAGE
MDS598007* 7.75" (19.7 cm) Insulated, Straight Tip each
MDS598107* 7.75" (19.7 cm) Insulated, Angled Tip each
MDS598207* 7.75" (19.7 cm) Non-Insulated, Straight Tip each
MDS598307* 7.75" (19.7 cm) Non-Insulated, Angled Tip each
MDS598008* 8.75" (22 cm) Insulated, Straight Tip each
MDS598108* 8.75" (22 cm) Insulated, Angled Tip each
MDS598208* 8.75" (22 cm) Non-Insulated, Straight Tip each
MDS598308* 8.75" (22 cm) Non-Insulated, Angled Tip each
* To select your tip, add “A” for 2.0 mm, “B” for 1.5 mm, “C” for 1.0 mm, “D” for 0.5 mm, or “E” for needle to the end of the item number.
MDS598007
* To select your tip, add “A” for 2.0 mm, “B” for 1.5 mm, “C” for 1.0 mm, “D” for 0.5 mm, or “E” for needle to the end of the item number.
Hardy
ITEM # SIZE DESCRIPTION PACKAGE
MDS599008* 8.75" (22 cm) Insulated, Straight Tip each
MDS599208* 8.75" (22 cm) Non-Insulated, Straight Tip each
MDS599009* 9.75" (24.7 cm) Insulated, Straight Tip each
MDS599209* 9.75" (24.7 cm) Non-Insulated, Straight Tip each
MDS599008
Bayonet Bipolar Forceps – Footswitching, 2-Pin Connection
padspencils
electrodesaccessories
forcepsgenerators
support1-800-MEDLINE | www.medline.com 31
Scoville Greenwood
ITEM # SIZE DESCRIPTION PACKAGE
MDS594007* 7.75" (19.7 cm) Insulated, Straight Tip each
MDS594207* 7.75" (19.7 cm) Non-Insulated, Straight Tip each
MDS594008* 8.75" (22 cm) Insulated, Straight Tip each
MDS594208* 8.75" (22 cm) Non-Insulated, Straight Tip each
* To select your tip, add “A” for 2.0 mm, “B” for 1.5 mm, “C” for 1.0 mm, “D” for 0.5 mm, or “E” for needle to the end of the item number.
MDS594007
Yasargil
ITEM # SIZE DESCRIPTION PACKAGE
MDS595006* 7" (17.8 cm) Insulated, Straight Tip each
MDS595206* 7" (17.8 cm) Non-Insulated, Straight Tip each
MDS595007* 8" (20.3 cm) Insulated, Straight Tip each
MDS595207* 8" (20.3 cm) Non-Insulated, Straight Tip each
* To select your tip, add “A” for 2.0 mm, “B” for 1.5 mm, “C” for 1.0 mm, “D” for 0.5 mm, or “E” for needle to the end of the item number.
MDS595007
forcepsfo
rceps
More lengths available —ask your Medline representative.
TIP SIZE SPECIFICATIONS
B1.5 mm
A2.0 mm
ENEEDLE
D0.5 mm
C1.0 mm
1-800-MEDLINE | www.medline.com32
REUSABLE BIPOLAR FORCEPS
More lengths available — ask your Medline representative.
Malis
ITEM # SIZE DESCRIPTION PACKAGE
MDS597008* 7.75" (19.7 cm) Insulated, Straight Tip each
MDS597108* 7.75" (19.7 cm) Insulated, Angled Tip each
MDS597208* 7.75" (19.7 cm) Non-Insulated, Straight Tip each
MDS597308* 7.75" (19.7 cm) Non-Insulated, Angled Tip each
MDS597009* 8.75" (22 cm) Insulated, Straight Tip each
MDS597109* 8.75" (22 cm) Insulated, Angled Tip each
MDS597209* 8.75" (22 cm) Non-Insulated, Straight Tip each
MDS597309* 8.75" (22 cm) Non-Insulated, Angled Tip each
* To select your tip, add “A” for 2.0 mm, “B” for 1.5 mm, “C” for 1.0 mm, “D” for 0.5 mm, or “E” for needle to the end of the item number.
FPO
Please note: items ending in “C” are only available with a 1.0 mm tip.
Gerald
ITEM # SIZE DESCRIPTION PACKAGE
MDS596006C 6.75" (17 cm) Insulated, Straight Tip each
MDS596206C 6.75" (17 cm) Non-Insulated, Straight Tip each
MDS596007C 7.75" (19.7 cm) Insulated, Straight Tip each
MDS596207C 7.75" (19.7 cm) Non-Insulated, Straight Tip each
MDS596007C
MDS597009
Bayonet Bipolar Forceps – Footswitching, 2-Pin Connection
padspencils
electrodesaccessories
forcepsgenerators
support1-800-MEDLINE | www.medline.com 33
Cushing
ITEM # SIZE DESCRIPTION PACKAGE
MDS591007* 7.75" (19.7 cm) Insulated, Straight Tip each
MDS591107* 7.75" (19.7 cm) Insulated, Angled Tip each
MDS591207* 7.75" (19.7 cm) Non-Insulated, Straight Tip each
MDS591307* 7.75" (19.7 cm) Non-Insulated, Angled Tip each
MDS591008* 8.75" (22 cm) Insulated, Straight Tip each
MDS591108* 8.75" (22 cm) Insulated, Angled Tip each
MDS591208* 8.75" (22 cm) Non-Insulated, Straight Tip each
MDS591308* 8.75" (22 cm) Non-Insulated, Angled Tip each
MDS591010* 10.75" (27.3 cm) Insulated, Straight Tip each
MDS591110* 10.75" (27.3 cm) Insulated, Angled Tip each
MDS591210* 10.75" (27.3 cm) Non-Insulated, Straight Tip each
MDS591310* 10.75" (27.3 cm) Non-Insulated, Angled Tip each
* To select your tip, add “A” for 2.0 mm, “B” for 1.5 mm, “C” for 1.0 mm, “D” for 0.5 mm, or “E” for needle to the end of the item number.
MDS591008
Reusable Accessories• Manufactured with the highest grade
of insulating materials available• 10’ in length• Fit all standard forceps
Reusable Bipolar Cord
ITEM # DESCRIPTION PACKAGE
MDS5990 Reusable Bipolar Cord, 10 ft (3.0 M) each
forcepsfo
rceps
More lengths available —ask your Medline representative.
TIP SIZE SPECIFICATIONS
B1.5 mm
A2.0 mm
ENEEDLE
D0.5 mm
C1.0 mm
There is no name more synonymous with electrosurgery than
Bovie. Dr. Bovie pioneered the use of electrosurgery more than
80 years ago, and many people still refer to their electrosurgical
equipment as their “Bovie.” Medline is proud to be the US distributor
of Bovie Electrosurgical generators.
Bovie generators feature fully digital implementation for use in
today’s modern OR and surgical outpatient centers. They’re easy to
handle yet capable of covering the whole spectrum of electrosurgical
interventions. The generator technology gives surgeons the fl exibility
to choose the desired type of effect with maximum convenience and
safety. Controlling the unit is easy, so the surgeon can concentrate on
what’s important – the operation and the patient.
refer to their electrosurgical
e.” Medline is proud to be the US distributor
urgical generators.
enerators feature fully digital implementation for use in
ay’s modern OR R anand d surgical outpatient centers. They’re easy to
handle yyyeet capable of coveriingngg ttheh wwhohole spectrum of electrosurgical
inteetervrveneentitiononnnono ss. The genererratattttoroooro ttecececece hnhnhnhnhnh olololoologogy gives susurgrgeons the fl exibility
toto ccchhohohooososee thht e e dededddddd isired tytytyypepepee oooffff efefeffeefefectcct wwwititithhh mamaaaxixix mum m convvenenience and
ssasafffetytyty. CConttttrororor llllllllinnnnininnggggggggggg ththe ununnnnnnnnnnnnnnnn titititit iiiisssssss eaeaeaeaeeasysysy,, sosososo tttheheeheheeeeee sssssssssssssuuuruuuuuuuuuuuuuuuuuruuuuruuuuuruu geon canan cconcentraratete on
wwhwhata ’ssss iiiimpmppororrrorro tataatantntntnttt –––– ttttttttthehhhhhhhehhhh ooppppepeppepepepepepeeeeeeeeeepeeeeeeeeerararaaarararraatittiononononononnonnononononnnnnnnoon aaaaaaaaaaaaaaaaaaaaaaaaaanndndndndndndndndndnnndndnnddndnddnd tttttttttttttttthehehehheehhhehhhhhh ppppppppppppppppaaaaaaataataaaaaaa ient.
BOVIE® GENERATORS, SMOKE EVACUATORS
36 … BOVIE ICON GP ELECTROSURGICAL
GENERATORS
38 … BOVIE IDS ELECTROSURGICAL
GENERATORS
40 … BOVIE SMOKE EVACUATOR
1-800-MEDLINE | www.medline.com34
padspencils
electrodesaccessories
forcepsgenerators
support1-800-MEDLINE | www.medline.com 35
padspencils
electrodesaccessories
padspencils
electrodesaccessories
forcepsgenerators
support
Bovie® Generators – the Most Recognized Name in Electrosurgery
SAFETY FEATURES
Safety is digitally designed inside
every model. The technology meets
the requirements of a variety of medical
specialties, procedures and indications in
the modern OR.
BovieFDFS™ (Fast Digital Feedback System)
This digitally controlled cut and coagulation
function senses tissue changes at a rate of
over 5 million times per second, for the most
consistent energy delivery available – no
other generator manufacturer today can
say that. FDFS controls tissue impedance
in real time, and adjusts power 5,000 times
per second, for an absolutely consistent
clinical effect.
BovieNEM™ (Neutral Electrode Monitoring)
The most advanced technology available for
preventing pad burns.
BovieFCFS™ (First Come First Served)
Discrete output design allows only one
output device to be activated at a time.
BovieDED™ (Digital Error Detection)
At any sign of a problem, the unit instantly
disables the output, sounds an alarm and
displays the appropriate error code.
Fully Digital ImplementationBovie generators do not require any
calibration.
EASY FINANCING
Medline offers several options to fi nance
the purchase of your new electrosurgical
generators. We offer capital purchase
fi nancing up to three years (interest-free up
to one year).* We can also build the cost of
the generators into your future sterile (off-
the-shelf) purchases or custom procedure
trays. Choose the payment plan that’s right
for you.
OUTSTANDING SERVICE
• 8-year warranty – the longest service
plan in the industry
• All Bovie generators ship FOB-
destination – FREE Freight
• Buy back availability for your old units
• Products and support available for trials
*Certain conditions may apply; specifi c fi nancing conditions are evaluated on a case-by-case basis.
generatorsg
enerato
rs
1-800-MEDLINE | www.medline.com36
Bovie Icon GP Electrosurgical GeneratorThe Icon GP is an intuitive electrosurgical generator with fully digital
implementation for use in today’s modern operating rooms. It was
designed in conjunction with OR clinicians to provide a safe, user-
friendly unit that can meet all operating room procedure demands.
A WIDE VARIETY OF MODES
Cut Modes
• Pure cut – Digitally controlled 300W maximum power ensures consistent performance
• Blended Cut – Three blend settings allow the surgeon to cut and coagulate at the same time
• Laparoscopic cut – Helps prevent capacitive coupling
• Special mode – Optimized for fl uid environments or may be tailored for a variety of applications
Coagulation Modes
• Pinpoint – Delivers rapid desiccation effect with minimal carbonization and less sticking of the active electrode
• Gentle – A gentler mode without carbonization
• Spray – Non-contact mode for controlling superfi cial bleeding
• Laparoscopic – Reduces risk of capacitive coupling
Bipolar Modes:
• Macro coagulation – Aggressive coagulation
• Micro coagulation – For precise applications
• Gentle coagulation – A gentler mode without carbonization
• Auto stop – Provides for extra convenience
SAFETY
• Bovie NEM, the most advanced safety technology available to help prevent pad burns
• Requires the use of only split pads for increased patient safety
• Laparoscopic modes help prevent capacitive coupling-induced burns
• Common sense error messaging prevents misinterpretation and allows for quicker troubleshooting
EASY TO USE
• Physician preference database facilitates quick changeovers
• Touch-screen interface with high-resolution TFT color display (no buttons or knobs)
• Swivel screen can be viewed from virtually any angle
UPGRADABLE
• Digitally controlled outputs and user interface make adding new modes easy
• Multiple communication ports (i.e., USB, RS 232 and Ethernet) allow for easy software updates
• New-accessory connector for future devices
BOVIE® GENERATORS
padspencils
electrodesaccessories
forcepsgenerators
support1-800-MEDLINE | www.medline.com 37
Icon GP Specifi cations
Reference GP 300Output Type RF Isolated “F"Output Power
Pure Cut 300W @ 300ΩBlend 200W @ 300ΩLaparoscopic Cut 300W @ 300ΩSpecial Cut 300W @ 300ΩPinpoint Coag 120W @ 500ΩSpray Coag 120W @ 500ΩLaparoscopic Coag 120W @ 500ΩGentle Coag 120W @ 125ΩMacro Bipolar 80W @ 100ΩMicro Bipolar 80W @ 100ΩAuto Stop 80W @ 100ΩGentle Bipolar 50W @ 25ΩOutput Frequency 492 kHz ±5
Line Voltage 100-240 VAC 50-60 Hz
Bovie Icon GP
ITEM # DESCRIPTION PACKAGE
ESUICONGP Electrosurgical Generator Icon GP each
ESUFOOTICON Monopolar Footswitch for Icon GP each
ESUFOOTGPB Bipolar Footswitch for Icon GP each
ESUADAPTOR Adapter for Footswitch Accessories each
ESUCARTGP Mobile Cart for Icon GP each
ESUICONGPC Icon GP Generator Plus Cart and Accessories (includes ESUICONGP, ESUFOOTICON, ESUFOOTGPB, ESUCARTGP) each
ESUFOOTICON ESUADAPTORESUFOOTGPB
generatorsg
enerato
rs
1-800-MEDLINE | www.medline.com38
EASY TO USE
• Plug and play – just plug the unit in and it’s ready to use
• No calibration required
CUTTING MODES
• Cut I Mode – A digitally controlled cutting quality that ensures performance when cutting adipose tissue or cutting underwater with minimal output power.
• Cut II Mode – A less aggressive cutting effect with the highest degree of safety for precise effects in general applications or microsurgery.
• Blended Cut – Ten blend settings allow the surgeon to cut and coagulate at the same time
COAGULATION MODES
• Pinpoint Coagulation Mode – Delivers a digitally controlled rapid desiccation effect with minimal carbonization and less sticking of the active electrode.
• Spray Coagulation Mode – Gives digitally controlled non-contact coagulation with a slight penetration of the tissue surface.
BIPOLAR MODE
• Uses digital technology to reduce instrument sticking and to minimize tissue destruction
The Surgeon’s Preset Center (IDS300 only) allows up to 10 surgeons to store their preferred power settings in the cut, coagulation, and bipolar modes.
Bovie IDS Electrosurgical GeneratorBovie IDS electrosurgical generators
provide a consistent clinical effect.
They’re easy to use, capable of
covering a whole spectrum of
electrosurgical interventions
and backed by the Bovie name.
BOVIE® GENERATORS
padspencils
electrodesaccessories
forcepsgenerators
support1-800-MEDLINE | www.medline.com 39
IDS Specifi cations
Reference IDS-300 IDS-200Output Type RF Isolated RF Isolated “F"Output Power
Cut I & II 300 W @ 300 Ω 200 W @ 300 Ω Blend 200 W @ 300 Ω 200 W @ 300 Ω Pinpoint 120 W @ 500 Ω 120 W @ 500 Ω Spray 80 W @ 500 Ω 80 W @ 500 Ω Bipolar 80 W @ 150 Ω 80 W @ 150 Ω
Duty Cycle 10 S / 30 S 10 S / 30 SOutput Frequency
490 kHz ± 5 490 kHz ± 5
Input Current 4.5 A ~ 4.5 A ~Line Voltage 100 - 240 V ~ 100 - 240 V ~Line Frequency 50-60 Hz 50-60 Hz
Bovie IDS
ITEM # DESCRIPTION PACKAGE
ESUIDS300 IDS-300 Electrosurgical Generator (300w) each
ESUIDS200 IDS-200 Electrosurgical Generator (200w) each
ESUFOOTSWITCH Monopolar Footswitch for Bovie IDS each
ESUFOOTSWICHB Bipolar Footswitch for Bovie IDS each
ESUADAPTOR Adapter for Footswitch Accessories each
ESUCART Mobile Cart for IDS generators each
ESUIDS300CIDS-300 Generator Plus Cart and Accessories (package includes ESUIDS300, ESUFOOTSWITCH, ESUFOOTSWICHB, ESUCART)
each
ESUIDS200CIDS-200 Generator Plus cart and Accessories (package includes ESUIDS200, ESUFOOTSWITCH, ESUFOOTSWICHB, ESUCART)
each
ESUFOOTSWITCH ESUADAPTORESUFOOTSWICHB
generatorsg
enerato
rs
1-800-MEDLINE | www.medline.com40
Bovie Smoke Shark™ The easy-to-use Bovie Smoke Shark is extremely effective at smoke and particle removal at
the operative site. Although it’s designed for use with electrosurgical generators, the Smoke
Shark is also excellent for controlling laser smoke.aser smoke.
Smoke Evacuator Specifi cations
DimensionsHeight 29.9 cm (11.8")Width 17.8 cm (7.0")Depth 46.4 cm (18.3")Weight < 6.5 kg (< 14 lbs.)
w/o fi lterLine Voltage SE01: 120 VAC
SE01-220: 240 VACLine Frequency 50 – 60 HzWarranty 2 years
Bovie Smoke Shark
ITEM # DESCRIPTION PACKAGE
ESUSMOKE Bovie Smoke Shark (does not inclue fi lter or tubing) each
ESUFILTER Smoke Evacuator 18-Hour Filter each
ARN786TSBX Sterile Tubing 24/cs
ARNSETWS Sterile Tubing with Wand 24/cs
BOVIE® SMOKE EVACUATORS
LONG-LIFE 18-HOUR FILTER
• Cost-effective – Combines four-stage fi ltration into one casing (pre-fi lter, ULPA, carbon, post-fi lter), keeping cost per procedure down and minimizing waste
• Powerful – Captures particles down to 0.01 µm with 99.99995% effi cacy
• Eliminates odors – Provides superior odor elimination via the 24 ounces of carbon in the fi lter
A SLEEK, POWERFUL,
SMOKE-EATING MACHINE!
• Easy to operate
• Quiet and effective
• Long-life, 18-hour fi lter
• Low cost per procedure
• Excellent particle capture
• Quality made in the U.S.A.
padspencils
electrodesaccessories
forcepsgenerators
support1-800-MEDLINE | www.medline.com 41
8000 Series
ITEM # DESCRIPTION PACKAGE
ESPB8000 Pencil, Push Button, Stainless Steel Tip, 1' Tubing 30/cs
ESRK8000 Pencil, Rocker, Stainless Steel Tip, 1' Tubing 30/cs
ESPB8002 Pencil, Push Button, PTFE Tip, 1' Tubing 30/cs
ESRK8002 Pencil, Rocker, PTFE Tip, 1' Tubing 30/cs
ESADPSM Adapter for Pencils, 1' Tubing 30/cs
ACCESSORIES
Electrosurgical Pencils with Smoke Evacuator Tubing
• A versatile tool in providing hands-free capture of hazardous electrosurgical plume
• Eliminates the need for another clinician to hold the tubing
• Ergonomic design features pliable silicone for extra comfort and visibility
• Easy clog removal
• Latex free
• The 8000 series pencils feature 3/8” diameter by 1’ tubing, with a 3/8” to 3/8” connector – ideal for use with wall suction systems
• The 9000 series pencils feature a total of 10’ tubing: 3/8” x 4’ tubing connected to 6’ x 7/8” tubing – ideal for use with smoke evacuation systems
9000 Series
ITEM # DESCRIPTION PACKAGE
ESPB9000 Pencil, Push Button, Stainless Steel Tip, 10' Tubing 16/cs
ESRK9000 Pencil, Rocker, Stainless Steel Tip, 10' Tubing 16/cs
ESPB9002 Pencil, Push Button, PTFE Tip, 10' Tubing 16/cs
ESRK9002 Pencil, Rocker, PTFE Tip, 10' Tubing 16/cs
ESADP10 Adapter for Pencils, 10' Tubing 16/cs
generatorsevacu
ators
SERVICE AND SUPPORT
OUR GUARANTEE
Medline stands behind the quality of our electrosurgical products,
whether they’re used on Bovie generators or other major brands
of generators in the market. Details are on the next page, in our
Guarantee and Indemnifi cation Policy.
ONGOING SUPPORT
We not only warranty our own generators, but those of our
competitors as well, at no charge, provided they are less than
eight years old – a Medline exclusive. So if you’re being told that
purchasing disposable electrosurgical products from another
company will void the warranty of your generator, don’t worry!
Medline will assume the warranty for you.*
We can also provide service on your generators
that are over 8 years old, and simply charge on
an as-needed basis.
*Certain conditions may apply.
1-800-MEDLINE | www.medline.com42
padspencils
electrodesaccessories
forcepsgenerators
support1-800-MEDLINE | www.medline.com 43
Guarantee: Medline Industries, Inc. fully recognizes its responsibilities as a manufacturer of healthcare products and warrants that reasonable care was used in the manufacture of its electrosurgical products. Medline will replace, at no charge, any electrosurgical products which fail to meet Medline’s standards of workmanship, materials or design, although Medline will not be responsible for damage after delivery due to accident, improper use or abuse, or failure to follow instructions provided by Medline. Included in this policy are electrosurgical generators, provided that any damage to such generators is proven to be solely caused by a defective Medline electrosurgical product or the incompatibility of the Medline product with the electrosurgical generator.
Indemnifi cation: Medline shall defend, hold harmless and indemnify the account for any and all losses, claims, judgments, and expenses (including but not limited to attorneys fees) relating to any claim of personal injury arising from or caused by any defect in the Medline electrosurgical product, provided that each of the following four conditions is satisfi ed:
(A) Such personal injury occurs during a surgical procedure in which the grounding pad is used in accordance with Medline’s instructions for use and only when used with an active accessory and electrosurgical generator with a functioning patient-contact monitoring system designed for use with a split style pad made by one of the following companies: Valleylab®, Conmed®, Aspen, Bard®, Birtcher, NDM, ERBE® and Bovie Medical.
(B) The personal injury is not caused by the account’s negligence or intentional misconduct, or as a result of a modifi cation to any of the machines, pads or cable.
(C) The Account notifi es Medline of the occurrence within a reasonable time thereafter, and has furnished prompt records of any and all claims of damage allegedly caused by defective Medline electrosurgical products, sent by registered or certifi ed mail addressed to Medline Offi ce of General Counsel, One Medline Place, Mundelein, IL 60060-4485.
(D) Medline controls the defense and resolution of any such claims, and the Account fully cooperates in such defense and resolution.
This agreement shall be valid and binding upon its execution by the account and Medline. This agreement constitutes the fi nal and complete agreement between the account and Medline and it terminates all prior written or oral agreements and understandings as to this agreement’s subject matter. Illinois law will apply in interpreting and enforcing this agreement.
Guarantee and Indemnifi cation Policy
support3
sup
po
rt
1-800-MEDLINE | www.medline.com44
INDEX
Electrosurgical Grounding Pads
ITEM PAGE
9165 Split, Precorded 9
9165L Split, Precorded with 15' Cord 9
9160 Split, Non-Corded 9
9160F Split, Non-Corded, 5/pk 9
9130 Standard (Non-Split), Non-Corded 9
9130F Standard (Non-Split), Non-Corded, 5/pk 9
9135-LP Standard (Non-Split), Precorded 9
1149 Large (Non-Split) Pad, Non-Corded 9
1149C-LP Large (Non-Split) Pad, Precorded 9
1179 Large Split Pad, Precorded 9
1180 Large Split Pad, Non-Corded 9
1180F Large Split Pad, Non-Corded, 5/pk 9
1181 Small Split Pad, Precorded 9
Reusable Cables
21172 10' (3.05 m) Reusable Cable for Solid Pads 11
21174 10' (3.05 m) Reusable Cable for Split Pads 11
21174L 15' (4.57 m) Reusable Cable for Split Pads 11
21174ABC 10' (3.05 m) Reusable Cable for Argon Beam Coagulators 11
Electrosurgical Pencils
ESPB3000 Push Button, Blade Electrode 14
ESRK3000 Rocker Switch, Blade Electrode 14
ESRK3000L Rocker Switch, Blade Electrode, 15' cord 14
ESFS3000 Footswitch, Blade Electrode 14
ESPB3002 Push Button, PTFE Blade Electrode 15
ESRK3002 Rocker Switch, PTFE Blade Electrode 15
ESFS3002 Footswitch, Blade Electrode 15
ESRK3002L Rocker Switch, PTFE Blade Electrode, 15' cord 15
ESPB2000 Push Button, Blade Electrode 16
ESPBN2000 Push Button, Needle Electrode 16
ESRK2000 Rocker Switch, Blade Electrode 16
ESFS2000 Footswitch, Blade Electrode 16
1-800-MEDLINE | www.medline.com 45
ind
ex
Electrosurgical Active Electrodes
ITEM PAGE
ES0012BL Blade Electrode, 2.5" (6.4 cm) 18
ES0012A Blade Electrode 2.75" (7 cm) 18
ES0012M Blade Electrode, Extended Insulation, 2.5" (6.4 cm) 18
ES0012AM Blade Electrode, Extended Insulation, 2.75" (7 cm) 18
ES0013 Needle Electrode, 2.75" (7 cm) 18
ES0013M Needle Electrode, Extended Insulation, 2.75" (7 cm) 18
ES0015 Ball Electrode, 0.06" (2 mm) Diameter, 2" Length (5 cm) 18
ES0014A Blade Electrode, 4" (10.2 cm) 19
ES0014AM Blade Electrode, Extended Insulation, 4" (10.2 cm) 19
ES0014 Blade Electrode, 6" (15.2 cm) 19
ES0014M Blade Electrode, Extended Insulation, 6" (15.2 cm) 19
ES0016 Needle Electrode, 6" (15.2 cm) 19
ES0016M Needle Electrode, Extended Insulation, 6" (15.2 cm) 19
ES0016AM Needle Electrode, Extended Insulation, 4" (10.2 cm) 19
ES0009 Ball Electrode, 0.19" (5 mm) Diameter, 5" Length (12.7 cm) 19
ESE1550 Ball Electrode, 0.19" (5 mm) Diameter, 2" Length 20
ESE1552 Needle Electrode, 2.84" (7.2 cm) 20
ESE155250 Needle Electrode, 2.84" (7.2 cm) 20
ESE1551X Blade Electrode, with Hex, 2.75" (7 cm) 20
ESE1551IX Blade Electrode, with Hex, Extended Insulation, 2.75" (7 cm) 20
ESE1552I Needle Electrode, Extended Insulation, 2.84" (7.2 cm) 20
ESE15516 Extended Blade Electrode, 6" (15.2 cm) 20
ESE15516IX Extended Blade Electrode, with Hex, Extended Insulation, 6.5" (16.5 cm) 20
ESE15526 Extended Needle Electrode, 6" (15.2 cm) 20
ESE1559 Tungsten Loop, 10 mm x 10 mm, 13 cm Length 21
ESE1560 Tungsten Loop, 15 mm x 12 mm, 13 cm Length 21
ESE1561 Tungsten Loop, 20 mm x 12 mm, 13 cm Length 21
ESE1562 Tungsten Loop, 20 mm x 15 mm, 13 cm Length 21
ESE1563 Stainless Steel Ball, 3 mm diameter, 13 cm Length 21
ESE1564 Stainless Steel Ball, 5 mm diameter, 13 cm Length 21
ESE1565 Tungsten Square, 5 mm x 5 mm, 13 cm Length 21
ESE1566 Tungsten Square, 10 mm x 4 mm, 13 cm Length 21
ESE1567 Tungsten Square Loop, 10 mm x 8 mm, 13 cm Length 21
ESE1510 Right Angle Hook Electrode, Insulated, with Safety Cap, 8.5" (21.6 cm) 22
1-800-MEDLINE | www.medline.com46
INDEX
Electrosurgical Active Electrodes (continued)
ITEM PAGE
ESE1511 45° Angle Hook Electrode, Insulated, with Safety Cap, 8.5" (21.6 cm) 22
ESE1512 Angled Blade Electrode, Insulated, with Safety Cap, 8.5" (21.6 cm) 22
ESE1650 Tungsten Needle with Insulation, 2 cm Straight 22
ESE1651 Tungsten Needle with Insulation, 3 cm Straight 22
ESE277028 Straight Spatula Tip, 11" (28 cm) 23
ESE277128 Curved Spatula Tip, 11" (28 cm) 23
ESE277228 Wire J Hook Tip, 11" (28 cm) 23
ESE277328 Wire L Hook Tip, 11" (28 cm) 23
ESE277428 Flat L Hook Tip, 11" (28 cm) 23
Accessories
DYNJ01208 Cautery Tip Polisher, 2" x 2", (6 cm x 6 cm) 25
DYNJ01207 Disposable Bipolar Cord, Sterile 25
ESH1 Electrosurgical Safety Holster 25
Reusable Bipolar Forceps
MDS571004C Insulated, Straight Tip, 4.75" (12 cm) 27
MDS571104C Insulated, Angled Tip, 4.75" (12 cm) 27
MDS571204C Non-Insulated, Straight Tip, 4.75" (12 cm) 27
MDS571304C Non-Insulated, Angled Tip, 4.75" (12 cm) 27
MDS572004E Insulated, Straight Tip, 4.25" (10.7 cm) 27
MDS572104E Insulated, Angled Tip, 4.25" (10.7 cm) 27
MDS572204E Non-Insulated, Straight Tip, 4.25" (10.7 cm) 27
MDS572304E Non-Insulated, Angled Tip, 4.25" (10.7 cm) 27
MDS573004E Insulated, Straight Tip, 3.75" (9.5 cm) 27
MDS573104E Insulated, Angled Tip, 3.75" (9.5 cm) 27
MDS573204E Non-Insulated, Straight Tip, 3.75" (9.5 cm) 27
MDS573304E Non-Insulated, Angled Tip, 3.75" (9.5 cm) 27
MDS574004D Insulated, Straight Tip, 4.25" (10.7 cm) 28
MDS574104D Insulated, Angled Tip, 4.25" (10.7 cm) 28
MDS574204D Non-Insulated, Straight Tip, 4.25" (10.7 cm) 28
MDS574304D Non-Insulated, Angled Tip, 4.25" (10.7 cm) 28
MDS575104 Insulated, Angled Tip, 4.75" (12 cm) 28
1-800-MEDLINE | www.medline.com 47
ind
ex
Reusable Bipolar Forceps (continued)
ITEM PAGE
MDS575304 Non-Insulated, Angled Tip, 4.75" (12 cm) 28
MDS587007 Insulated, Straight Tip, 6.25" (14 cm) 28
MDS587207 Non-Insulated, Straight Tip, 6.25" (14 cm) 28
MDS587008 Insulated, Straight Tip, 6.75" (17 cm) 28
MDS587208 Non-Insulated, Straight Tip, 6.75" (17 cm) 28
MDS589009E Insulated, Straight Tip, 6.75" (17 cm) 29
MDS589209E Non-Insulated, Straight Tip, 6.75" (17 cm) 29
MDS581006 Insulated, Straight Tip, 6.75" (17 cm) 29
MDS581106 Insulated, Angled Tip, 6.75" (17 cm) 29
MDS581206 Non-Insulated, Straight Tip, 6.75" (17 cm) 29
MDS581306 Non-Insulated, Angled Tip, 6.75" (17 cm) 29
MDS581007 Insulated, Straight Tip, 7.75" (19.7 cm) 29
MDS581107 Insulated, Angled Tip, 7.75" (19.7 cm) 29
MDS581207 Non-Insulated, Straight Tip, 7.75" (19.7 cm) 29
MDS581307 Non-Insulated, Angled Tip, 7.75" (19.7 cm) 29
MDS586006C Insulated, Straight Tip, 6.75" (15 cm) 29
MDS586206C Non-Insulated, Straight Tip, 6.75" (15 cm) 29
MDS586007C Insulated, Straight Tip, 7.75" (19.7 cm) 29
MDS586207C Non-Insulated, Straight Tip, 7.75" (19.7 cm) 29
MDS598007 Insulated, Straight Tip, 7.75" (19.7 cm) 30
MDS598107 Insulated, Angled Tip, 7.75" (19.7 cm) 30
MDS598207 Non-Insulated, Straight Tip, 7.75" (19.7 cm) 30
MDS598307 Non-Insulated, Angled Tip, 7.75" (19.7 cm) 30
MDS598008 Insulated, Straight Tip, 8.75" (22 cm) 30
MDS598108 Insulated, Angled Tip, 8.75" (22 cm) 30
MDS598208 Non-Insulated, Straight Tip, 8.75" (22 cm) 30
MDS598308 Non-Insulated, Angled Tip, 8.75" (22 cm) 30
MDS599008 Insulated, Straight Tip, 8.75" (22 cm) 30
MDS599208 Non-Insulated, Straight Tip, 8.75" (22 cm) 30
MDS599009 Insulated, Straight Tip, 9.75" (24.7 cm) 30
MDS599209 Non-Insulated, Straight Tip, 9.75" (24.7 cm) 30
MDS594007 Insulated, Straight Tip, 7.75" (19.7 cm) 31
MDS594207 Non-Insulated, Straight Tip, 7.75" (19.7 cm) 31
1-800-MEDLINE | www.medline.com48
INDEX
Reusable Bipolar Forceps (continued)
ITEM PAGE
MDS594008 Insulated, Straight Tip, 8.75" (22 cm) 31
MDS594208 Non-Insulated, Straight Tip, 8.75" (22 cm) 31
MDS595006 Insulated, Straight Tip, 7" (17.8 cm) 31
MDS595206 Non-Insulated, Straight Tip, 7" (17.8 cm) 31
MDS595007 Insulated, Straight Tip, 8" (20.3 cm) 31
MDS595207 Non-Insulated, Straight Tip, 8" (20.3 cm) 31
MDS597008 Insulated, Straight Tip, 7.75" (19.7 cm) 32
MDS597108 Insulated, Angled Tip, 7.75" (19.7 cm) 32
MDS597208 Non-Insulated, Straight Tip, 7.75" (19.7 cm) 32
MDS597308 Non-Insulated, Angled Tip, 7.75" (19.7 cm) 32
MDS597009 Insulated, Straight Tip, 8.75" (22 cm) 32
MDS597109 Insulated, Angled Tip, 8.75" (22 cm) 32
MDS597209 Non-Insulated, Straight Tip, 8.75" (22 cm) 32
MDS597309 Non-Insulated, Angled Tip, 8.75" (22 cm) 32
MDS596006C Insulated, Straight Tip, 6.75" (17 cm) 32
MDS596206C Non-Insulated, Straight Tip, 6.75" (17 cm) 32
MDS596007C Insulated, Straight Tip, 7.75" (19.7 cm) 32
MDS596207C Non-Insulated, Straight Tip, 7.75" (19.7 cm) 32
MDS591007 Insulated, Straight Tip, 7.75" (19.7 cm) 33
MDS591107 Insulated, Angled Tip, 7.75" (19.7 cm) 33
MDS591207 Non-Insulated, Straight Tip, 7.75" (19.7 cm) 33
MDS591307 Non-Insulated, Angled Tip, 7.75" (19.7 cm) 33
MDS591008 Insulated, Straight Tip, 8.75" (22 cm) 33
MDS591108 Insulated, Angled Tip, 8.75" (22 cm) 33
MDS591208 Non-Insulated, Straight Tip, 8.75" (22 cm) 33
MDS591308 Non-Insulated, Angled Tip, 8.75" (22 cm) 33
MDS591010 Insulated, Straight Tip, 10.75" (27.3 cm) 33
MDS591110 Insulated, Angled Tip, 10.75" (27.3 cm) 33
MDS591210 Non-Insulated, Straight Tip, 10.75" (27.3 cm) 33
MDS591310 Non-Insulated, Angled Tip, 10.75" (27.3 cm) 33
MDS5990 Reusable Bipolar Cord, 10' (3 m) 33
1-800-MEDLINE | www.medline.com 49
ind
ex
Bovie Smoke Evacuators and Accessories
ESUSMOKE Bovie Smoke Shark 40
ESUFILTER Smoke Evacuator 18-Hour Filter 40
ARN786TSBX Sterile Tubing 40
ARNSETWS Sterile Tubing with Wand 40
ESPB8000 Pencil, Push Button, Stainless Steel Tip, 1' Tubing 41
ESRK8000 Pencil, Rocker, Stainless Steel Tip, 1' Tubing 41
ESPB8002 Pencil, Push Button, PTFE Tip, 1' Tubing 41
ESRK8002 Pencil, Rocker, PTFE Tip, 1' Tubing 41
ESADPSM Adapter for Pencils, 1' Tubing 41
ESPB9000 Pencil, Push Button, Stainless Steel Tip, 10' Tubing 41
ESRK9000 Pencil, Rocker, Stainless Steel Tip, 10' Tubing 41
ESPB9002 Pencil, Push Button, PTFE Tip, 10' Tubing 41
ESRK9002 Pencil, Rocker, PTFE Tip, 10' Tubing 41
ESADP10 Adapter for Pencils, 10' Tubing 41
Bovie Generators
ITEM PAGE
ESUICONGP Electrosurgical Generator Icon GP 37
ESUFOOTICON Monopolar Footswitch for Icon GP 37
ESUFOOTGPB Bipolar Footswitch for Icon GP 37
ESUADAPTOR Adapter for Footswitch Accessories 37
ESUCARTGP Mobile Cart for Icon GP 37
ESUICONGPC Icon GP Generator Plus Cart and Accessories 37
ESUIDS300 IDS-300 Electrosurgical Generator (300w) 39
ESUIDS200 IDS-200 Electrosurgical Generator (200w) 39
ESUFOOTSWITCH Monopolar Footswitch for Bovie IDS 39
ESUFOOTSWICHB Bipolar Footswitch for Bovie IDS 39
ESUADAPTOR Adapter for Footswitch Accessories 39
ESUCART Mobile Cart for IDS generators 39
ESUIDS300C IDS-300 Generator Plus Cart and Accessories 39
ESUIDS200C IDS-200 Generator Plus cart and Accessories 39
Medline United States1-800-MEDLINE (633-5463)www.medline.com [email protected]
Medline Canada1-800-396-6996www.medline.ca [email protected]
Medline México01-800-831-0898www.medlinemexico.com [email protected]
Medline Industries, Inc.One Medline PlaceMundelein, IL 60060
Some products may not be available for sale in Mexico or Canada. We reserve the right to correct any errors that may occur within this brochure. ©2011 Medline Industries, Inc. Medline and Blue Silk are registered trademarks of Medline Industries, Inc. Bovie is a registered trademark and BovieFDFS, BovieNEM, BovieFCFS, BovieDED, and Bovie Smoke Shark are trademarks of Bovie Medical Corporation. iPhone and Apple are registered trademarks of Apple Inc. Corporation. Tefl on is a registered trademark of E. I. du Pont de Nemours and Company. 3M and Micropore are trademarks of 3M Company. PenAdapt is a trademark of Buffalo Filter Corporation. Valleylab is a registered trademark of Covidien AG Corp., Conmed is a registered trademark of Conmed Corporation, Bard is a registered trademark of C. R. Bard, Inc., ERBE is a registered trademark of Erbe Elektromedizin GmbH. MKT211097 / LIT106 / 10M / SG / 22
ELECTROSURGERY ONLINE
➊ Download a QR Code reader app➋ Launch app➌ Hover the phone over this QR Code
MEDLINE UNIVERSITYYour source for clinical training and resources
FREE Continuing Education Join the thousands of nurses who log on to Medline
University every day to earn continuing education
credits on a wide variety of subjects.* Courses include
“Electrocautery Safety and OR Fire Prevention” and
“Electrosurgery Safety Considerations.” Over 50 courses!
New courses added every month.
Easy-to-use
Online, interactive courses
Downloadable podcasts (audio files)
Downloadable pdf documents
NEW! iPhone® apps available at The Apple® store
Informative
Video of today’s leading healthcare industry
experts sharing their insights on critical issues.
Online magazine articles from The OR Connection, Healthy Skin and Infection Prevention NowLinks to up-to-date healthcare news stories
*Courses approved for continuing education by the
Florida Board of Nursing and the California Board of
Registered Nursing
Get started today!Setting up an account at Medline University is as easy:
1. Go to www.medlineuniversity.com2. Select “Create Account” in top right corner3. Complete the brief online form to register
for your free account
and Healthy Skin
FREE Continuing EducationJoin the thousands of nurses who log on to MedlineUniversity every day to earn continuing educationcredits on a wide variety of subjects Courses include“Electrocautery Safety and OR Fire Prevention” and “Electrosurgery Safety Considerations.” Over 50 courses!New courses added every month.*
Online magazine articles from The OR Connection and Healthy Skin