B B A B A B B A B A B A 168.50 169.50 170.50 167.50 166.65 1 ISSUED FOR 75% REVIEW 25/02/2021 NOT FOR CONSTRUCTION AS NOTED 22/02/2020 ZC MK 20-087 3 1. THE COPYRIGHT OF THIS DRAWING IS VESTED IN O'M ENGINEERING INC. AND IT MAY NOT BE REPRODUCED IN WHOLE OR PART OR USED FOR THE MANUFACTURE OF ANY ARTICLE WITHOUT THE EXPRESS PERMISSION OF THE COPYRIGHT HOLDERS. 2. WORK TO FIGURED DIMENSIONS ONLY. 3. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECT'S, SERVICE ENGINEER'S AND O'M ENGINEERING INC. DRAWINGS AND SPECIFICATIONS. SHEFFIELD PARK 3510 SHEFFIELD AVENUE COQUITLAM, BCV3E 3H1 CITY OF COQUITLAM N 2 ISSUED FOR BUILDING PERMIT R1 3 ISSUED FOR 95% REVIEW 18/03/2021 LANDSCAPE ARCHITECT: ARCHITECT: 10/03/2021 22/04/2021 4 ---- --/--/---- 5 ISSUED FOR RFP E00 COVER SHEET, SYMBOL SCHEDULE AND DRAWING LIST DRAWING LIST E00 COVER SHEET, SYMBOL SCHEDULE, KEY PLAN, DRAWING LIST E01 SITE PLAN E02 WASHROOM ELECTRICAL AND LIGHTING PLAN E03 ELECTRICAL DETAILS E05 ELECTRICAL SPECIFICATIONS SHEFFIELD PARK COQUITLAM, BC SCALE: KEY PLAN 1 E00 1:200 DIRECT EQUIPMENT CONNECTION MECHANICAL MOTOR CONNECTION DISCONNECT SWITCH SPECIAL RECEPTACLE AS DESIGNATED ABBREVIATIONS: "TYP" = TYPICAL "HK" = HOUSE KEEPING "WP" = WEATHER PROOF "WAP" = WIRELESS ACCESS POINT "GFCI" = GROUND FAULT CIRCUIT INTERRUPTER "FR" = FRIDGE (DEDICATED RECEPTACLE) "MW" = MICROWAVE (DEDICATED RECEPTACLE) "DW" = DISHWASHER "RNG" = RANGE "RNGHD" = RANGHOOD "WSHR" = WASHING MACHINE "AFF" = ABOVE FINISHED FLOOR "+XX" = DIMENSIONED HEIGHT ABOVE FINISHED FLOOR "EM" = EMERGENCY POWERED LUMINAIRE KEY NOTE SECTION DETAIL MISCELLLANEOUS 2 XX XX MECHANICAL EQUIPMENT TAG GROUND BUS GROUND FAULT INTERRUPTER FOUR PLEX RECEPTACLE PANEL SURFACE 5-20R GFCI DUPLEX RECEPTACLE T THERMOSTAT POWER DISTRIBUTION & ELECTRONIC SYSTEMS EQUIPMENT 5-20R DUPLEX RECEPTACLE (T-SLOT) LIGHTINGS AND LUMINAIRE FIXTURE CEILING RECESSED LINEAR LUMINAIRE SURFACE MOUNTED LINEAR LUMINAIRE 4x1 ES ELECTRIC STRIKE DUPLEX RECEPTACLE OCCUPANCY SENSOR (MANUAL ON - AUTO OFF) WALL MOUNTED OCCUPANCY SENSOR (MANUAL ON - AUTO OFF) OS OS PANEL SURFACE PUSH BUTTON ELECTRICAL ENERGY DESIGN STATEMENT: BRITISH COLUMBIA BUILDING CODE: 2018 SCOPE OF WORK

Transcript of DRAWINGS AND SPECIFICATIONS. SECTION DETAIL OS XX ...

B

B

A

B

A

B

B

A

B

A

B

A

168.50

169.50

170.50

167.50166.65

1 ISSUED FOR 75% REVIEW 25/02/2021

NOT FOR CONSTRUCTION

AS NOTED 22/02/2020 ZC MK

20-087 3

1. THE COPYRIGHT OF THIS DRAWING IS VESTED IN O'M ENGINEERINGINC. AND IT MAY NOT BE REPRODUCED IN WHOLE OR PART OR USEDFOR THE MANUFACTURE OF ANY ARTICLE WITHOUT THE EXPRESSPERMISSION OF THE COPYRIGHT HOLDERS.

2. WORK TO FIGURED DIMENSIONS ONLY.

3. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANTARCHITECT'S, SERVICE ENGINEER'S AND O'M ENGINEERING INC.DRAWINGS AND SPECIFICATIONS.

SHEFFIELD PARK3510 SHEFFIELD AVENUECOQUITLAM, BCV3E 3H1

CITY OF COQUITLAM

N

2 ISSUED FOR BUILDING PERMIT R1

3 ISSUED FOR 95% REVIEW 18/03/2021

LANDSCAPE ARCHITECT:

ARCHITECT:

10/03/2021

22/04/20214---- --/--/----5ISSUED FOR RFP

E00

COVER SHEET, SYMBOLSCHEDULE AND DRAWINGLIST

DRAWING LIST

E00 COVER SHEET, SYMBOL SCHEDULE, KEY PLAN, DRAWING LIST

E01 SITE PLAN

E02 WASHROOM ELECTRICAL AND LIGHTING PLAN

E03 ELECTRICAL DETAILS

E05 ELECTRICAL SPECIFICATIONS

SHEFFIELD PARKCOQUITLAM, BC

SCALE:KEY PLAN1

E00 1:200

DIRECT EQUIPMENT CONNECTION

MECHANICAL MOTOR CONNECTION

DISCONNECT SWITCH

SPECIAL RECEPTACLE AS DESIGNATED

ABBREVIATIONS:"TYP" = TYPICAL"HK" = HOUSE KEEPING"WP" = WEATHER PROOF"WAP" = WIRELESS ACCESS POINT"GFCI" = GROUND FAULT CIRCUIT INTERRUPTER"FR" = FRIDGE (DEDICATED RECEPTACLE)"MW" = MICROWAVE (DEDICATED RECEPTACLE)"DW" = DISHWASHER"RNG" = RANGE"RNGHD" = RANGHOOD"WSHR" = WASHING MACHINE"AFF" = ABOVE FINISHED FLOOR"+XX" = DIMENSIONED HEIGHT ABOVE FINISHED FLOOR"EM" = EMERGENCY POWERED LUMINAIRE

KEY NOTE

SECTION DETAIL

MISCELLLANEOUS

2

XXXX MECHANICAL EQUIPMENT TAG

GROUND BUS

GROUND FAULT INTERRUPTER FOUR PLEX RECEPTACLE

PANEL SURFACE

5-20R GFCI DUPLEX RECEPTACLE

T THERMOSTAT

POWER DISTRIBUTION & ELECTRONIC SYSTEMS EQUIPMENT

5-20R DUPLEX RECEPTACLE (T-SLOT)

LIGHTINGS AND LUMINAIRE FIXTURE

CEILING RECESSED LINEAR LUMINAIRE

SURFACE MOUNTED LINEAR LUMINAIRE 4x1

ES ELECTRIC STRIKE

DUPLEX RECEPTACLE

OCCUPANCY SENSOR (MANUAL ON - AUTO OFF)

WALL MOUNTED OCCUPANCY SENSOR (MANUAL ON - AUTO OFF)

OS

OS

PANEL SURFACE

PUSH BUTTON

ELECTRICAL ENERGY DESIGN STATEMENT:

BRITISH COLUMBIA BUILDING CODE: 2018

SCOPE OF WORK

AutoCAD SHX Text
TOP OF SLOPE
AutoCAD SHX Text
NO-ENCROACHMENT-ZONE
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESCRIPTION:
AutoCAD SHX Text
REV:
AutoCAD SHX Text
Notes:
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
PROJECT NO:
AutoCAD SHX Text
DRAWING NO:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
SCALE AT A0:
AutoCAD SHX Text
STATUS:
AutoCAD SHX Text
PROJECT NAME/ADDRESS:
AutoCAD SHX Text
CLIENT:
AutoCAD SHX Text
DRAWING TITLE:
AutoCAD SHX Text
PROJECT NORTH:
AutoCAD SHX Text
2
AutoCAD SHX Text
E-4

B

B

A

B

A

B

B

A

B

A

B

A

168.50

169.50

170.50

167.50166.65

TOP OF BANKTOP OF BANK

DITCH TOP

HYDROKIOSK

HYDROKIOSK

HYDROVAULT HYDRO

VAULTHYDROVAULT

HYDROVAULT

CURB FACE

CURB FACE

CURB FACE

DITCH TOP

DITCH TOP

SAN STUB

STM STUB

S35A

HYDRO STUB

HYDRO STUB HYDRO STUB

4 6

2

5

1

3

BC HYDRO KISOK

1x2" CONDUIT FOR BC HYDRO SERVICEAND 1x2" SPARE CONDUIT

4

7

ELECTRICAL PANEL

TO EXISTING BC HYDRO STUB

1x2" CONDUIT

FD FD

8

IT PANEL

3

1x2" CONDUIT IT AND COMMUNICATIONSTERMINATED AT PROPERTY LINE

1 ISSUED FOR 75% REVIEW 25/02/2021

NOT FOR CONSTRUCTION

AS NOTED 22/02/2020 ZC MK

20-087 3

1. THE COPYRIGHT OF THIS DRAWING IS VESTED IN O'M ENGINEERINGINC. AND IT MAY NOT BE REPRODUCED IN WHOLE OR PART OR USEDFOR THE MANUFACTURE OF ANY ARTICLE WITHOUT THE EXPRESSPERMISSION OF THE COPYRIGHT HOLDERS.

2. WORK TO FIGURED DIMENSIONS ONLY.

3. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANTARCHITECT'S, SERVICE ENGINEER'S AND O'M ENGINEERING INC.DRAWINGS AND SPECIFICATIONS.

SHEFFIELD PARK3510 SHEFFIELD AVENUECOQUITLAM, BCV3E 3H1

CITY OF COQUITLAM

N

2 ISSUED FOR BUILDING PERMIT R1

3 ISSUED FOR 95% REVIEW 18/03/2021

LANDSCAPE ARCHITECT:

ARCHITECT:

10/03/2021

22/04/20214---- --/--/----5ISSUED FOR RFP

E01

SITE PLAN

GENERAL NOTES:A. CONTRACTOR TO REVIEW LANDSCAPE ARCHITECTURAL AND SPLASH PARK DESIGN DRAWING FOR

EXACT QUANTITY AND LOCATION OF METAL INSERTS ETC. REQUIRED TO BE BONDED TO BONDED TOGROUND.

B. BONDING CONNECTION LAYOUT SHOWN FOR DIAGRAMMATIC PURPOSE ONLY. ACTUAL QUANTITYAND LOCATION OF REQUIRED CONNECTIONS MAY EXCEED THAT WHICH IS SHOWN IN ORDER TOACCOMMODATE ACTUAL SITE CONSTRUCTION CONDITIONS AND INSTALLATIONS CONTRACTOR TOMAKE ALLOWANCES AS NECESSARY TO PROVIDE A COMPLETE GROUNDING/BONDING SYSTEM. ALLGROUNDING AND BONDING IS TO BE DONE AS PER REQUIREMENTS OF LATEST EDITION OF CEC ANDLOCAL AHJ.

C. PROVIDE #6 AWG Cu. GROUND JUMPERS FOR ALL METAL DEVICES, PANELS, BASE FRAMES ANDMETAL GUTTER COMPONENTS. CONFORM ALL BONDING REQUIREMENTS WITH SPLASH PARKMANUFACTURER.

D. SPLASH PARK RE-ENFORCING STEEL MUST BE BONDED WITH MINIMUM OF SEVEN CONNECTIONSEQUALLY SPACED AROUND THE PERIMETER AS INDICATED.

E. RIGID CONDUIT (COPPER OR OTHER CORROSION-RESISTANT METAL OR RIGID PVC) MUST BE USED.

F. ALL METAL PARTS OF THE SPLASH PARK AND OTHER NON-ELECTRICAL EQUIPMENT ASSOCIATEDWITH THE SPLASH PARK ARE TO BE BONDED. IN PARTICULAR, THE CONTRACTOR SHALL NOTE THATALL DOWEL BARS AND BARS ARE REQUIRED TO BE BONDED. BONDED IN PARTICULAR,THECONTRACTOR SHALL NOTE THAT ALL DOWEL BARS AND TIE BARS ARE REQUIRED TO BE BONDED.

G. ALL BONDING WIRE CONNECTIONS TO EACH OTHER SHALL BE COMPRESSION TYPE.

H. UNDERGROUND CONDUIT, GROUND WIRE AND BONDING JUMPERS SHALL BE RUN UNDER NEW SLABAREAS. CONTRACTOR SHALL AVOID ANY DIGGING UNDER TREE PROTECTION AREAS.

DRAWING KEY NOTES:1. 2" CONDUIT TO BUILT IN GFCI RECEPTACLE ON PARK IDENTIFIER SIGN. PROVIDE LEVITON 4996-KIT

WEATHERPROOF RECEPTACLE ENCLOSURE. SUPPLY AND INSTALLATION OF PARK IDENTIFIER SIGN,FOUNDATION AND PAD BY OTHERS.

2. PROVIDE MINIMUM #6AWG BARE COPPER GROUND LOOP AROUND THE SPLASH PARK. GROUND LOOPAND BONDING JUMPERS SHALL BE RUN UNDER NEW SLAB AREAS. AVOID RUNNING CONDUIT/WIRINGUNDER TREE PROTECTION AREAS.

3. SPLASH PARK ACTIVATOR BASE. PROVIDE TWO (2) MINIMUM #6AWG BARE COPPER GROUND WIRECONNECTIONS FROM GROUND POINT (ACTIVATOR BASE) TO THE GROUND LOOP AROUND SPLASHPARK. PROVIDE 1" CONDUIT FROM ACTIVATOR BASE TO ACTIVATOR FOR LOW VOLTAGE WIRING. THEBLANK ON TOP OF THE BASE SHALL BE MAINTAINED TO ENSURE THE UNIT IS WATERTIGHT.

4. PROVIDE MINIMUM #6AWG BARE COPPER BONDING JUMPERS FROM GROUND LOOP AND CONNECT TORE-ENFORCING STEEL (REBAR IN CONCRETE), TO ALL ELECTRICAL AND METAL EQUIPMENT WITHIN THESPLASH PARK AND TO ALL METAL PARTS OF THE SPLASH PARK. COORDINATE WITH ARCHITECT ANDOTHER TRADES ON SITE TO ENSURE ALL METAL PARTS WITHIN VICINITY OF THE SPLASH PARK ISGROUNDED PROPERLY AS REQUIRED BY CEC AND LOCAL AHJ. TYPICAL.

5. NEW SPLASH PARK ACTIVATORS. ACTIVATORS SHALL BE INSTALLED ON A PLAYPHASE BASE.

6. A 2" CONDUIT SHALL RUN FROM EACH ACTIVATOR BASE TO PANEL P IN THE SERVICE ROOM.

7. SERVICE NEUTRAL GROUNDING RING CONNECTED TO GROUND BUS IN SERVICE ROOM AS PER DETAIL#4 DWG E03.

8. CONDUIT SHALL BE STUBBED AT BC HYDRO METER ON EXTERIOR OF WASHROOM BUILDING. SEEDETAIL #1 DWG E02.

SCALE:SITE PLAN1

E01 1:200

AutoCAD SHX Text
TOP OF SLOPE
AutoCAD SHX Text
NO-ENCROACHMENT-ZONE
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
DCO
AutoCAD SHX Text
S
AutoCAD SHX Text
DCO
AutoCAD SHX Text
D
AutoCAD SHX Text
DCO
AutoCAD SHX Text
168.49
AutoCAD SHX Text
S
AutoCAD SHX Text
J
AutoCAD SHX Text
50
AutoCAD SHX Text
J
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
S
AutoCAD SHX Text
J
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
50
AutoCAD SHX Text
D
AutoCAD SHX Text
50
AutoCAD SHX Text
J
AutoCAD SHX Text
DCO
AutoCAD SHX Text
DCO
AutoCAD SHX Text
DCO
AutoCAD SHX Text
50
AutoCAD SHX Text
DCO
AutoCAD SHX Text
DCO
AutoCAD SHX Text
DCO
AutoCAD SHX Text
DCO
AutoCAD SHX Text
DCO
AutoCAD SHX Text
DCO
AutoCAD SHX Text
DCO
AutoCAD SHX Text
5
AutoCAD SHX Text
E03
AutoCAD SHX Text
6
AutoCAD SHX Text
E03
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESCRIPTION:
AutoCAD SHX Text
REV:
AutoCAD SHX Text
Notes:
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
PROJECT NO:
AutoCAD SHX Text
DRAWING NO:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
SCALE AT A0:
AutoCAD SHX Text
STATUS:
AutoCAD SHX Text
PROJECT NAME/ADDRESS:
AutoCAD SHX Text
CLIENT:
AutoCAD SHX Text
DRAWING TITLE:
AutoCAD SHX Text
PROJECT NORTH:

FD FD

B

3

A

1 2

BBH-1

IT PANEL

IRRIGATIONPANEL

PANEL P

EF-1

EF-2

1

ES

23

GROUND BUS

27mmC Typ.

BC HYDRO METER

5

P-2

P-4

P-6

P-10

P-12

6

9

T

7

8

4

JB

1011

12

FD FD

B

3

A

1 2

'B'

'A'

OSOS

'C'

1 ISSUED FOR 75% REVIEW 25/02/2021

NOT FOR CONSTRUCTION

AS NOTED 22/02/2020 ZC MK

20-087 3

1. THE COPYRIGHT OF THIS DRAWING IS VESTED IN O'M ENGINEERINGINC. AND IT MAY NOT BE REPRODUCED IN WHOLE OR PART OR USEDFOR THE MANUFACTURE OF ANY ARTICLE WITHOUT THE EXPRESSPERMISSION OF THE COPYRIGHT HOLDERS.

2. WORK TO FIGURED DIMENSIONS ONLY.

3. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANTARCHITECT'S, SERVICE ENGINEER'S AND O'M ENGINEERING INC.DRAWINGS AND SPECIFICATIONS.

SHEFFIELD PARK3510 SHEFFIELD AVENUECOQUITLAM, BCV3E 3H1

CITY OF COQUITLAM

N

2 ISSUED FOR BUILDING PERMIT R1

3 ISSUED FOR 95% REVIEW 18/03/2021

LANDSCAPE ARCHITECT:

ARCHITECT:

10/03/2021

22/04/20214---- --/--/----5ISSUED FOR RFP

E02

WASHROOM ELECTRICALAND LIGHTING PLAN

SCALE:ELECTRICAL PLAN1

E02 1:30

DRAWING KEY NOTES1. POWER CONNECTION FOR ELECTRONIC HAND DRYER.

2. POWER CONNECTION AND MOTOR FOR AUTOMATIC DOOR OPENER.

3. ELECTRONIC STRIKE TO BE CONTROLLED REMOTELY BY CLIENT.

4. OPERATOR ACTUATOR FOR AUTOMATIC DOOR (TYPICAL), WITH KEY-SWITCH FOR MAG LOCKOVERRIDE ABOVE. KEY-SWITCH SHALL CONNECT TO JUNCTION BOX CONCEALED ABOVEWINDOW. KEY-SWITCH SHALL BE SUPPLIED BY OWNER. (960-MA KEY SWITCH) COORDINATEWITH ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF DEVICES.

5. BASEBOARD HEATERS SHALL BE OUELLET OFM0502 OR APPROVED EQUAL.

6. CONNECT TO GROUNDING SYSTEM AS PER DETAIL #4 DWG E03. CONTRACTOR SHALLTERMINATE SERVICE GROUND CABLES ONTO GROUND BUS.

7. PROVIDE IN-FLOOR RADIANT HEATING IN WASHROOM. IN-FLOOR RADIANT HEATING MAT SHALLBE OUELLET OWC-MO500 HEATING CABLE. CONTRACTOR SHALL INSTALL MAT AS PERMANUFACTURER'S REQUIREMENTS. PROVIDE GFCI BREAKER ON PANEL P.

8. HARDWIRED CONNECTION FOR WASHROOM IN-FLOOR RADIANT HEATING CABLE.

9. PROVIDE THERMOSTAT FOR IN-FLOOR RADIANT HEATING. THERMOSTAT SHALL BE OUELLETOTH3600 NON-PROGRAMMABLE THERMOSTAT.

10. PROVIDE JUNCTION BOX CONCEALED ABOVE WINDOW FOR DOOR MAG LOCK AND OPERATOR.PROVIDE CONDUIT FROM JUNCTION BOX TO PANEL P. COORDINATE WITH ARCHITECTURALDRAWINGS FOR EXACT LOCATIONS OF DEVICES.

11. 2" CONDUIT FROM IRRIGATION PANEL TO EXTERIOR WALL. CONDUIT SHALL BE CAPPED ANDSEALED AT EXTERIOR.

12. COORDINATE EXACT LOCATION OF METER WITH ARCHITECTURAL DRAWINGS PRIOR TOINSTALLATION.

SCALE:LUMINAIRE SCHEDULE3

E02 N/A

SCALE:MECHANICAL SCHEDULE4

E02 N/A

AREALIGHTINGCONTROL

TECHNOLOGY

MEANS TO TURN ONLUMINAIRE ADDITIONAL LIGHTING CONTROLS MEANS TO TURN OFF

LUMINAIRE

WASHROOM LINE VOTAGE AUTO ON OCCUPANCY SENSOR AUTO OFF

SERVICE ROOM VACANCY SENSORS MANUAL ON VACANCY SENSOR AUTO OFF AFTER 20 MINS

EXTERNAL LIGHTING PHOTOCELL WITHTIMECLOCK AUTO ON TIME SCHEDULE WITH PHOTOCELL AUTO OFF

SCALE:LIGHTING CONTROL SEQUENCE OF OPERATION4

E02 N/A

SCALE:LIGHTING PLAN2

E02 1:30

AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESCRIPTION:
AutoCAD SHX Text
REV:
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
PROJECT NO:
AutoCAD SHX Text
DRAWING NO:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
SCALE AT A0:
AutoCAD SHX Text
STATUS:
AutoCAD SHX Text
PROJECT NAME/ADDRESS:
AutoCAD SHX Text
CLIENT:
AutoCAD SHX Text
DRAWING TITLE:
AutoCAD SHX Text
PROJECT NORTH:

1 X 53mmC

1Ø120Y/240200A

200A1P

PANEL

P

M BCH METER

BC HYDRO STUB

WEST SIDE OF SHEFFIELD PARK

OUTSIDE SERVICE ROOM

INSIDE SERVICE ROOM

1000mm MIN.

300mm

P1

P1 = 53mm RPVC FOR POWER CONNECTION

FINISHED GRADE

PROVIDE 3/ 4 MINUS ROAD MULCHUNDER PAVED AREAS COMPACTED IN200 mm LIFTS. ELSEWHERE, NATIVEMATERIAL BACKFILL COMPACTED IN200mm LIFTS

CLEAN SAND

S1

MARKING TAPE

80mm

S1 = 53mm RPVC FOR SPARE

C1 = 53mm RPVC FOR DATA AND COMMUNICATIONS

1000mm MIN.

300mm

C1

FINISHED GRADE

PROVIDE 3/ 4 MINUS ROAD MULCHUNDER PAVED AREAS COMPACTED IN200 mm LIFTS. ELSEWHERE, NATIVEMATERIAL BACKFILL COMPACTED IN200mm LIFTS

CLEAN SAND

MARKING TAPE

1 ISSUED FOR 75% REVIEW 25/02/2021

NOT FOR CONSTRUCTION

AS NOTED 22/02/2020 ZC MK

20-087 3

1. THE COPYRIGHT OF THIS DRAWING IS VESTED IN O'M ENGINEERINGINC. AND IT MAY NOT BE REPRODUCED IN WHOLE OR PART OR USEDFOR THE MANUFACTURE OF ANY ARTICLE WITHOUT THE EXPRESSPERMISSION OF THE COPYRIGHT HOLDERS.

2. WORK TO FIGURED DIMENSIONS ONLY.

3. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANTARCHITECT'S, SERVICE ENGINEER'S AND O'M ENGINEERING INC.DRAWINGS AND SPECIFICATIONS.

SHEFFIELD PARK3510 SHEFFIELD AVENUECOQUITLAM, BCV3E 3H1

CITY OF COQUITLAM

N

2 ISSUED FOR BUILDING PERMIT R1

3 ISSUED FOR 95% REVIEW 18/03/2021

LANDSCAPE ARCHITECT:

ARCHITECT:

10/03/2021

22/04/20214---- --/--/----5ISSUED FOR RFP

E03

ELECTRICAL DETAILS

SCALE:SINGLE LINE DIAGRAM1

E03 N/A

PANEL PDESCRIPTION BRKR POLES CCT A B CCT POLES BRKR DESCRIPTION

NE RECEPTACLE 20 1P 1 2 1P 15 IT PANEL

SPLASH PARK 15 1P 3 4 1P 15 IT PANEL

SPLASH PARK 15 1P 5 6 1P 15 IRRIGATION PANEL

EF-1/EF-2 15 1P 7 8 1P 15 DOOR HARDWARE

BBH-1 15 1P 9 10 1P 20 RECEPTACLE

BBH-2 15 1P 11 12 1P 20 RECEPTACLE

HAND DRYER 15 1P 13 14 1P 15 SPARE

DRINKING FOUNTAIN 15 1P 15 16 1P 15 SPARE

IN-FLOOR HEATING MAT 15 1P 17 18 1P 15 SPARE

THERMOSTAT 15 1P 19 20 1P 20 SPARE

INTERIOR LIGHTING 15 1P 21 22 1P 20 SPARE

EXTERIOR LIGHTING 15 1P 23 24 1P 20 SPARE

SPACE 25 26 SPACE

SPACE 27 28 SPACE

SPACE 29 30 SPACE

SPACE 31 32 SPACE

SPACE 33 34 SPACE

SPACE 35 36 SPACE

SPACE 37 38 SPACE

SPACE 39 40 SPACE

SPACE 41 42 SPACE

SURFACE MOUNTED WITH HINGE DOOR

SCALE:PANEL SCHEDULE2

E03 N/A

SCALE:GROUNDING BUS DETAIL3

E03 NTS

SIZE AS REQUIRED

51

102

102

102

SCALE:SERVICE GROUNDING DETAIL4

E03 NTS

DUCT #4

DUCT #3

HIGH VOLTAGE LOW VOLTAGEVERY LOW

VOLTAGE (COMM)

DUCT #3

DUCT #4

HIGH VOLTAGE

LOW VOLTAGE

VERY LOWVOLTAGE (COMM)

GAS

WATER

SEWER

150 mm

300 mm

300 mm 300 mm

75 mm

75 mm

150 mm150 mm150 mm

300 mm300 mm300 mm

300 mm300 mm300 mm

d

SCALE:CROSSOVER DUCT SEPARATION7

E03 NTS

SCALE:POWER DUCT RUN DETAIL5

E03 NTS

SCALE:COMMUNCATIONS DUCT RUN DETAIL6

E03 NTS

DUCT #4DUCT #3

HIGH VOLTAGE LOW VOLTAGEVERY LOW

VOLTAGE (COMM)

DUCT #3

DUCT #4

HIGH VOLTAGE

LOW VOLTAGE

VERY LOWVOLTAGE (COMM)

GAS

WATER

SEWER

75 mm

300 mm

300 mm 300 mm

75 mm

75 mm

300 mm300 mm300 mm

900 mm900 mm900 mm

900 mm900 mm900 mm

300 mm

300 mm 300 mm

SCALE:HORIZONTAL DUCT SEPARATION8

E03 NTS

AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESCRIPTION:
AutoCAD SHX Text
REV:
AutoCAD SHX Text
Notes:
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
PROJECT NO:
AutoCAD SHX Text
DRAWING NO:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
SCALE AT A0:
AutoCAD SHX Text
STATUS:
AutoCAD SHX Text
PROJECT NAME/ADDRESS:
AutoCAD SHX Text
CLIENT:
AutoCAD SHX Text
DRAWING TITLE:
AutoCAD SHX Text
PROJECT NORTH:

1. GENERAL

.1

.2

.3

.4

.5

.6

.7

.8

.9

GENERAL REQUIREMENTS, INSTRUCTIONS TO BIDDERS, THIS SPECIFICATION AND ANY ADDENDA HERETO FORM PART OF THE CONTRACT DOCUMENTS AND SHALL BE READ IN CONJUNCTION WITH THEM. WORK TO INCLUDE THE FURNISHING OF ALL LABOR AND MATERIALS, UNLESS SPECIFIED OTHERWISE, TO COMPLETE AND PUT INTO OPERATING CONDITION ALL ELECTRICAL SYSTEMS AS INDICATED ON THE DRAWINGS AND SPECIFIED HEREIN.

IT IS THE INTENT OF THE WORK TO PROVIDE COMPLETE, NEATLY FINISHED, AND OPERATIONAL SYSTEMS AND ANY LABOR, MATERIAL, PERMITS, LICENSES, APPROVALS AND INSPECTIONS REQUIRED FOR COMPLETION OF THE WORK, WHETHER SPECIFICALLY MENTIONED IN THE DRAWINGS OR SPECIFICATIONS OR NOT, ARE TO BE INCLUDED IN THE PROPOSAL PRICE.

RESPONSIBILITY AS TO WHICH TRADE PROVIDES REQUIRED ARTICLES OR MATERIALS RESTS SOLELY WITH THE GENERAL CONTRACT TRADE. EXTRAS WILL NOT BE CONSIDERED BASED ON GROUNDS OF DIFFERENCE OF INTERPRETATION OF SPECIFICATIONS AS TO WHICH TRADE INVOLVED SHALL PROVIDE CERTAIN SPECIALTIES OR MATERIALS.

THE DRAWINGS AND SPECIFICATIONS FOR THE COMPLETE WORKS, INCLUDING ALL OF THOSE RELATED TO OTHER TRADES ARE TO BE EXAMINED BEFORE SUBMITTING TENDERS. ALL ELECTRICAL AND COMMUNICATIONS REQUIREMENTS INDICATED ARE TO BE INCLUDED IN THE SCOPE OF THE WORK.

CLEAN UP AND REMOVE ALL UNUSED WIRING AND CONDUITS.

REMOVE AND REINSTALL EXISTING DEVICES TO FACILITATE CONSTRUCTION AS REQUIRED.

CONFIRM OUTLET LOCATIONS AND MOUNTING HEIGHT WITH PROJECT COORDINATOR ON SITE PRIOR TO INSTALLATION.

ALL PENETRATIONS MADE THROUGH FIRE RATED ASSEMBLIES SHALL BE FIRE STOPPED PER FIRE STOP SPECIFICATIONS SECTION.

COORDINATE WITH AND GET APPROVAL FROM LANDLORD FOR ALL DRILLING, CORING AND CUTTING OF BUILDING STRUCTURE. COORDINATE LOCATIONS ON SITE PRIOR TO CARRYING OUT THE WORK. ALLOW FOR ALL COSTS FOR X-RAYING/SCANNING. CONTRACTOR MUST OBTAIN WRITTEN APPROVAL FROM THE LANDLORD STRUCTURAL ENGINEER PRIOR TO COMMENCEMENT OF THE WORK.

.10 CONTRACTORS SHALL PROVIDE ALL NECESSARY TEMPORARY POWER ANDLIGHTING AS REQUIRED.

.11 WHERE TENANT SPACES ARE OCCUPIED BY THE CLIENT, ALL NOISY WORKSUCH AS (BUT NOT RESTRICTED TO) CORING, WIRING AND CABLING PULLING,INSTALLATION OF CONDUIT SHALL BE DONE AFTER HOURS. WIRINGCONNECTIONS TO SYSTEMS FURNITURE SHALL BE COORDINATED WITHOWNER, INCLUDING CABLING TERMINATIONS

2. DRAWINGS AND SPECIFICATIONS

.1

.2

DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY TO EACH OTHER AND WHAT IS CALLED FOR BY ONE IS TO BE BINDING AS IF CALLED FOR BY BOTH.

SHOULD ANY DISCREPANCY APPEAR BETWEEN DRAWINGS AND SPECIFICATIONS THAT LEAVES THE ELECTRICAL TRADE IN DOUBT AS TO TRUE INTENT AND MEANING, OBTAIN RULING FROM THE ELECTRICAL CONSULTANT PRIOR TO SUBMITTING PROPOSAL, OR ALLOW FOR THE MOST EXPENSIVE ALTERNATIVE.

3. EXAMINATION OF OTHER DRAWINGS

.1 THE ELECTRICAL CONTRACTOR IS TO EXAMINE CAREFULLY STRUCTURAL, ARCHITECTURAL AND MECHANICAL DRAWINGS, AND THE WORK OF OTHER TRADES AND SATISFY HIMSELF THAT THE WORK UNDER THIS CONTRACT CAN BE SATISFACTORILY CARRIED OUT WITHOUT CHANGES TO THE BUILDING AS SHOWN ON THE PLANS. SHOULD ANY DIFFICULTY ARISE SHOWING CONFLICT WITH, OR REQUIRING ADDITIONAL WORK BEYOND THE WORK OF THESE DRAWINGS, BRING THIS MATTER TO THE ATTENTION OF THE ENGINEER BEFORE SUBMITTING PROPOSAL.

4. UNIFORMITY OF EQUIPMENT

.1 UNLESS OTHERWISE SPECIFIED, UNIFORMITY OF MANUFACTURE IS TO BEMAINTAINED FOR ANY PARTICULAR ITEM THROUGHOUT.

5. STANDARDS OF MATERIAL AND WORKMANSHIP

.1 ALL MATERIALS ARE TO BE NEW AND OF THE QUALITY SPECIFIED, AND SHALLBE APPROVED BY CSA OR EQUIVALENT AGENCY RECOGNIZED IN BRITISHCOLUMBIA.

.2 ALL WORK SHALL BE EXECUTED IN A NEAT AND WORKMANLIKE MANNER BYQUALIFIED TRADESMEN. THE ELECTRICAL CONTRACTOR SHALL KEEP ACOMPETENT FOREMAN AND NECESSARY ASSISTANTS ON THE SITE DURINGTHE PROGRESS OF THE WORK.

.3 ALL MATERIAL AND INSTALLATION SHALL MATCH BUILDING STANDARDUNLESS IT IS NOTED OTHERWISE ON THE DRAWINGS.

6. RECORD PLANS & MAINTENANCE MANUALS

.1

.2

.3

.4

THE ELECTRICAL CONSULTANT WILL FURNISH TO THE ELECTRICAL TRADE ONE SET OF DRAWINGS TO BE USED FOR AS-BUILT PURPOSES. THE ELECTRICAL TRADE IS TO ACCURATELY RECORD ON THESE PRINTS ALL REVISIONS TO THE ORIGINAL PLANS THAT ARE MADE ON SITE DURING CONSTRUCTION.

THE ELECTRICAL TRADE IS TO PRODUCE AT HIS OWN EXPENSE A SET OF RED LINE MARK-UP AS-BUILT DRAWINGS, INCLUDING ALL CHANGES TO THE ORIGINAL RFP DRAWINGS COVERED BY ADDENDA, CHANGE ORDERS, FIELD CHANGES, AND JOB CONDITIONS, AND TURN THESE OVER TO THE ENGINEER IN HARD COPY FORM. COMPLETED AS-BUILT DRAWINGS ARE TO BE CLEARLY MARKED "CERTIFIED AS-BUILT DRAWINGS". REFER TO LINE ITEM 3.

O'M ENGINEERING SHALL PRODUCE THE RECORD DRAWINGS IN AUTOCAD FORMAT BASED ON THE CERTIFIED AS-BUILT DRAWINGS RECEIVED FROM THE CONTRACTOR. CONTRACTOR SHALL ASSIST O'M ENGINEERING IN INTERPRETING ILLEGIBLE OR INDECIPHERABLE RED LINE MARK-UPS.

THIS CONTRACTOR SHALL PROVIDE 3 THREE-RING BINDERS FOR MAINTENANCE MANUALS. MANUALS SHALL CONTAIN ALL WARRANTIES, SHOP DRAWINGS, INSPECTION LETTERS, PANEL SCHEDULES, ETC. IN ADDITION TO THE HARD COPY, THE CONTRACTOR SHALL SUBMIT A SOFTCOPY OF THE MAINTENANCE MANUAL VIA USB DRIVE OR BY THE MEANS OF ELECTRONIC FILE TRANSFER.

7. SHOP DRAWINGS

.1 THE ELECTRICAL CONTRACTOR IS TO SUBMIT TO THE ELECTRICALCONSULTANT, FOR REVIEW, SHOP DRAWINGS OF MAJOR ELECTRICALEQUIPMENT. SUCH EQUIPMENT SHALL INCLUDE, BUT NOT BE LIMITED TOSWITCHGEAR, PANELBOARDS, SERIES-RATED BREAKER COMBINATIONS,FIXTURES AND FITTINGS NOT PROVIDED BY THE OWNER.

.2 ALL DRAWINGS ARE TO BE SUBMITTED IN PDF FORMAT VIA ELECTRONIC FILETRANSFER.

.3 THE ELECTRICAL CONSULTANT'S REVIEW OF SHOP DRAWINGS IS TO BE FORGENERAL DESIGN ONLY AND WILL NOT RELIEVE THE ELECTRICALCONTRACTOR OR SUPPLIERS FROM RESPONSIBILITY FOR ERRORS, PROPERFITTING, CONSTRUCTION OF WORK, AND FURNISHING OF MATERIALS.REVIEW WILL NOT BE CONSTRUED AS APPROVING DEPARTURES FROMCONTRACT DOCUMENT REQUIREMENTS IF SUCH DEPARTURES ARE NOTSPECIFICALLY NOTED. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FORVERIFYING ALL DIMENSIONS.

8. GUARANTEE WARRANTY

.1 THE ELECTRICAL CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEEWARRANTY, SIGNED BY AUTHORIZED PERSONNEL, STATING:

.1 THAT ALL WORK EXECUTED UNDER THIS CONTRACT WILL BE FREEFROM DEFECTS OF MATERIAL AND WORKMANSHIP FOR A PERIOD OF 1

YEAR FROM DATE OF SUBSTANTIAL COMPLETION.

.2 THE ABOVE PARTIES FURTHER AGREE TO, AT THEIR OWN EXPENSE,REPAIR AND REPLACE ALL SUCH DEFECTIVE WORK, AND OTHERWORK DAMAGED THEREBY, WHICH FAILS OR BECOMES DEFECTIVEDURING THE TERM OF THE GUARANTEE WARRANTY PROVIDED THATSUCH FAILURE IS NOT DUE TO IMPROPER USAGE.

.3 THE PERIOD OF THE GUARANTEE SPECIFIED WILL IN NO WAYSUPPLANT ANY OTHER GUARANTEE OF A LONGER PERIOD BUT BEBINDING ON WORK NOT OTHERWISE COVERED.

9. SETTING OUT OF THE WORK

.1 THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR CORRECTING ALLWORK COMPLETED CONTRARY TO THE INTENT OF DRAWINGS ANDSPECIFICATIONS AND SHALL BEAR ALL COSTS INVOLVED IN MAKING THECORRECTIONS. WHERE INTENT OF DRAWINGS AND SPECIFICATIONS IS NOTCLEAR, OBTAIN CLARIFICATION FROM THE ELECTRICAL CONSULTANTBEFORE PROCEEDING WITH WORK.

.2 THE ELECTRICAL CONTRACTOR IS TO GIVE WORK HIS PERSONALSUPERVISION, LAY OUT HIS OWN WORK, DO ALL NECESSARY LEVELING ANDMEASURING OR EMPLOY A COMPETENT ENGINEER TO DO SO. FIGURES, FULLSIZE AND DETAIL DRAWINGS TO TAKE PRECEDENCE OVER SCALEMEASUREMENTS.

.3 THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGECAUSED TO THE OWNER OR ANY OTHER TRADE BY IMPROPER LOCATION ORCARRYING OUT OF HIS WORK.

.4 THE ELECTRICAL CONTRACTOR , IN THE SETTING OUT OF HIS WORK, IS TOMAKE REFERENCE TO ARCHITECTURAL, STRUCTURAL, AND MECHANICALDRAWINGS. HE SHALL CONSULT WITH ALL RELEVANT TRADES IN SETTINGOUT LOCATIONS FOR CONDUIT RUNS, LIGHTING FIXTURES, PANELASSEMBLIES, AND ALL OTHER ELECTRICAL EQUIPMENT, SO THAT CONFLICTSARE AVOIDED AND SYMMETRICAL SPACING IS MAINTAINED.

.5 THE ELECTRICAL CONTRACTOR SHALL CONFIRM OUTLET LOCATIONS ANDMOUNTING HEIGHTS WITH THE PROJECT COORDINATOR ON SITE PRIOR TOINSTALLATION.

.6 WHERE RECEPTACLES ARE MOUNTED ABOVE COUNTERS, BENCHES,SPLASHBACKS, OR OTHER FIXTURES, THEIR LOCATIONS AND MOUNTINGHEIGHTS ARE TO BE COORDINATED WITH THE BUILT-IN UNITS. REFER TOARCHITECTURAL DETAILS. WHERE RECEPTACLES OCCUR IN OUTSIDE WALLSWHERE HEATING UNITS ALSO OCCUR, RECEPTACLE HEIGHT TO BEADJUSTED TO COORDINATE WITH THE HEATING UNITS.

.7 SWITCH MOUNTING HEIGHTS ARE TO BE COORDINATED WITHARCHITECTURAL DETAILS AND SHALL BE ADJUSTED, IF REQUIRED, TOCOORDINATE WITH PANELING, DADOS, MASONRY COURSE LINES, OR OTHERRELEVANT BUILDING FEATURES.

.8 WHERE OUTLET BOXES OCCUR IN EXTERIOR WALLS, THE ELECTRICALCONTRACTOR IS TO ENSURE THAT THERE IS INSULATION BEHIND THEOUTLET BOXES TO PREVENT CONDENSATION THROUGH THE BOXES.

.9 ALLOW FOR WORK AFTER HOURS AS REQUIRED AND COORDINATE WITHOWNER/TENANTS IF APPLICABLE.

.10 CONTRACTOR TO COORDINATE ANY INTERRUPTIONS TO ADJOININGTENANTS IN ORDER TO AVOID ANY INCONVENIENCES TO SAID TENANT. IFNECESSARY CONTRACTOR TO DO ANY REQUIRED CONNECTIONS ON OFFHOURS

10. EXAMINATION OF THE SITE

.1 PRIOR TO SUBMITTING PROPOSAL, THE ELECTRICAL CONTRACTOR SHALL CAREFULLY EXAMINE THE SITE AND ASCERTAIN ALL CONDITIONS WHICH MAY AFFECT HIS TRADE. NO ADDITIONAL MONEY WILL BE ALLOWED FOR WORK RESULTING FROM CONDITIONS THAT SHOULD HAVE BEEN NOTICED AND ACCOUNTED FOR DURING A THOROUGH EXAMINATION OF THE SITE.

11. CUTTING AND PATCHING

.1 THE GENERAL TRADE WILL BE RESPONSIBLE FOR ALL CUTTING ANDPATCHING REQUIRED FOR ELECTRICAL INSTALLATION. STRUCTURALMEMBERS MUST NOT BE CUT WITHOUT CONSENT OF THE STRUCTURALENGINEER.

.2 WHERE WORK DONE BY THE ELECTRICAL TRADE DAMAGES THE WORK OFOTHER TRADES, THE ELECTRICAL TRADE SHALL REPAIR AND MAKE GOODSUCH DAMAGE TO THE SATISFACTION OF EACH TRADE CONCERNED ANDTHE ENGINEER.

12. CLEANUP

.1 THE ELECTRICAL CONTRACTOR AND HIS SUB-TRADES ARE TO KEEP THESITE FREE DURING CONSTRUCTION OF DEBRIS, BOXES, PACKING, ANDOTHER MATERIALS ASSOCIATED WITH THE WORK OF THIS TRADE. ALLWASTE MATERIAL IS TO BE DISPOSED OF IN A SAFE AND ENVIRONMENTALLYRESPONSIBLE MANNER.

.2 UPON COMPLETION OF WORK, THE ELECTRICAL INSTALLATION SHALL BELEFT IN A CLEAN AND FINISHED CONDITION TO THE SATISFACTION OF THEELECTRICAL CONSULTANT.

13. ACCESS DOORS

.1 THE ELECTRICAL CONTRACTOR IS TO SUPPLY AND INSTALL ACCESS DOORSAS REQUIRED FOR PROPER SERVICING OF ALL ELECTRICAL WORK. ACCESSDOORS SHALL BE COMPLETE WITH NECESSARY FRAMES AND HINGEDDOORS HELD CLOSED WITH CAPTIVE STUDS. ACCESS PANEL TO BE OF NOTLESS THAN 14 GAUGE STEEL, PRIME COAT FINISHED AND PAINTED ON THEJOB TO MATCH THE WALL OR CEILING FINISH.

.2 THE NUMBER OF ACCESS DOORS SHALL BE KEPT TO A MINIMUM.

.3 THE ELECTRICAL CONTRACTOR SHALL PROVIDE ACCESS PANELS IN THEDRYWALL CEILINGS FOR ALL ELECTRICAL JUNCTION BOXES AND EQUIPMENTIN ACCORDANCE WITH APPLICABLE CODES.

14. CODES, PERMITS AND INSPECTION

.1 THE ENTIRE INSTALLATION, INCLUSIVE OF MATERIAL AND LABOR, IS TOCOMPLY WITH ALL THE REQUIREMENTS OF ALL APPLICABLE BUILDINGCODES AND AUTHORITIES HAVING JURISDICTION, THE CANADIANELECTRICAL CODE, AND REGULATIONS OF THE LOCAL INSPECTIONDEPARTMENT.

.2 THE ELECTRICAL CONTRACTOR IS TO OBTAIN ALL PERMITS REQUIRED FOREACH STAGE OF WORK, AND AFTER COMPLETION OF THE ENTIREINSTALLATION FURNISH TO THE ELECTRICAL CONSULTANT A CERTIFICATEOF FINAL INSPECTION AND APPROVAL FROM THE ELECTRICAL INSPECTIONDEPARTMENT OF THE AUTHORITY HAVING JURISDICTION.

15. MECHANICAL EQUIPMENT

.1 UNLESS SPECIFIED OTHERWISE, THE ELECTRICAL CONTRACTOR IS TOSUPPLY AND INSTALL ALL REQUIRED CONDUIT, WIRING, ELECTRICALFITTINGS AND CONNECTIONS FOR ALL MOTORS AND OTHER ELECTRICALEQUIPMENT, EVEN THOUGH SUCH MOTORS AND OTHER ELECTRICALEQUIPMENT MAY BE SUPPLIED BY OTHERS. WHERE REQUIRED BY THEDRAWINGS OR APPLICABLE REGULATIONS, DISCONNECT SWITCHES,STARTERS, OVERLOAD RELAYS AND OTHER NECESSARY PROTECTIVEDEVICES ARE TO BE SUPPLIED AND INSTALLED BY THE ELECTRICALCONTRACTOR. MOTORS AND CONTROLS SHALL BE FURNISHED BY THESUPPLIER OF THE DRIVEN EQUIPMENT. THE ELECTRICAL CONTRACTORSHALL INCLUDE ALL WORK AND CONNECTIONS REQUIRED TO MAKE THESYSTEM COMPLETE AND OPERATIONAL.

.2 THE ELECTRICAL EQUIPMENT MAY INCLUDE BUT NOT BE LIMITED TO SUCHITEMS AS GRILLE MOTORS AND INTERLOCKS, STOREFRONT AND INTERIORSIGNAGE, STARTING DEVICES, MOTOR CONTROLLERS, FLOAT SWITCHES,ALARM DEVICES OR SYSTEMS, PUSH BUTTONS, EXHAUST FANS, DATASYSTEMS, INTERCOMS AND STEREO SYSTEMS.

.3 THE ELECTRICAL CONTRACTOR IS TO CONFIRM MOTOR (OR OTHEREQUIPMENT) LOCATION AND SIZES WITH THE TRADE SUPPLYING THE MOTOR(OR OTHER EQUIPMENT) BEFORE COMMENCING ANY ASSOCIATEDELECTRICAL WORK.

.4 WHERE A VARIABLE FREQUENCY DRIVE (VFD) IS PROVIDED BY OTHERS, THEELECTRICAL CONTRACTOR SHALL PROVIDE WIRING BETWEEN THEOVER-CURRENT DEVICE AND VFD, AND BETWEEN THE VFD AND MOTOR.

16. TESTS

.1 ALL PORTIONS OF ELECTRICAL WORK ARE TO BE TESTED FORSATISFACTORY OPERATION.

.2 BEFORE ENERGIZING ANY PORTION OF THE ELECTRICAL SYSTEM, THEELECTRICAL CONTRACTOR SHALL PERFORM MEGGER TESTS ON ALLFEEDERS OVER 60A. ANY PROBLEMS DISCOVERED BY SUCH TESTING ARETO BE CORRECTED BY THE ELECTRICAL CONTRACTOR AND THE CIRCUITS INQUESTION RETESTED. THE RESULTS OF ALL FINAL TESTING SHALL BEPROVIDED TO THE ELECTRICAL CONSULTANT IN REPORT FORM.

.3 UPON PROJECT COMPLETION, AND IMMEDIATELY PRIOR TO FINALINSPECTION AND TAKEOVER, THE ELECTRICAL CONTRACTOR SHALL CHECKTHE LOAD BALANCE ON ALL FEEDERS AND AT DISTRIBUTION CENTRES, LOADCENTRES, AND PANELS. THESE CHECKS ARE TO BE CARRIED OUT BYTURNING ON ALL LOADS AND CHECKING LOAD CURRENT BALANCE. IF LOADUNBALANCE EXCEEDS 15 %, THE CIRCUITS ARE TO BE RECONFIGURED ASNECESSARY TO BALANCE THE LOADS.

17. PAINTING AND FINISHES

.1 ALL ELECTRICAL FITTINGS, SUPPORTS, HANGER RODS, PULLBOXES,CHANNEL FRAMES, CONDUIT RACKS, OUTLET BOXES, BRACKETS, ANDCLAMPS ARE TO HAVE A GALVANIZED FINISH OR A PAINT FINISH OVERCORROSION-RESISTANT PRIMER.

.2 ALL PANELS ARE TO BE FACTORY-FINISHED WITH SPRAY-ON AIR DRYENAMEL. ALL ENAMEL TO BE APPLIED OVER CORROSION-RESISTANT PRIMER.MATTE OR FLAT TYPE FINISH PAINT WILL NOT BE ACCEPTED. ALL PANELS ORSIMILAR FACTORY-FINISHED UNITS THAT ARE SCRATCHED OR MARKEDDURING INSTALLATION ARE TO BE TOUCHED UP WITH MATCHING SPRAY-ONAIR DRY LACQUER AND, IF REQUIRED TO PROVIDE A SATISFACTORY JOB, TOBE COMPLETELY REFINISHED.

.3 ALL PANELBOARDS, PULLBOXES, AND OTHER ELECTRICAL CABINETS ANDBOXES ARE TO BE FINISHED IN GRAY ENAMEL.

18. PATHWAYS

.1 WHERE REQUIRED BY THE CANADIAN ELECTRICAL CODE, ALL WIRE ANDCABLE IS TO BE INSTALLED IN EMT CONDUIT.

.2 UNLESS OTHERWISE NOTED, EMT CONDUIT ARE TO BE CONCEALED IN ALLFINISHED AREAS. IN SERVICE AREAS, CONDUIT AND EMT SHALL BE RUN ONSURFACE UNLESS INDICATED OTHERWISE.

.3 SURFACE MOUNTED EMT CONDUIT ARE TO BE INSTALLED PARALLEL TOSTRUCTURAL LINES, AND, WHERE BENDS OCCUR IN PARALLEL RUNS, THEYSHALL BE CONCENTRIC.

.4 RACEWAYS ARE TO BE INSTALLED FREE FROM DENTS AND BRUISES ANDSHALL HAVE THEIR ENDS CAPPED, PLUGGED, OR SEALED AS NECESSARY TOPREVENT ENTRANCE OF DIRT OR MOISTURE.

.5 IN ALL AREAS SUBJECT TO MOISTURE, WATERTIGHT FITTINGS MUST BEUSED.

.6 ALL RACEWAY, EXCEPT WHERE OTHERWISE INDICATED, SHALL BE SIZED INACCORDANCE WITH THE CANADIAN ELECTRICAL CODE.

.7 TECK90 OR SEAL TIGHT FLEXIBLE CONDUIT IS BE UTILIZED FORCONNECTIONS TO MOTORS AND MOTOR CONTROLLERS.

.8 ALL UNDERGROUND CONDUIT SYSTEMS ARE TO BE OF APPROVED RPVCSCHEDULE 40 CONDUIT, COMPLETE WITH INSTALLED BONDING CONDUCTOR,AND INSTALLED AT OR BELOW THE DEPTH REQUIRED BY CODE. PROVIDE150mm CLEAN SAND BEDDING ABOVE AND 75mm BELOW CONDUITS ANDCONTINUOUS MARKING TAPE 300mm BELOW GRADE. PROVIDE SUITABLEBACKFILL AND COMPACTION.

19. EXPANSION JOINTS

.1 WHERE CONDUITS ARE INSTALLED IN CONCRETE SLABS OR CROSSSTRUCTURAL EXPANSION JOINTS, AN APPROVED EXPANSION FITTING SHALLBE INSTALLED.

20. WIRE AND CABLE

.1 ALL BUILDING WIRING IS TO BE RW90, 600V, COPPER, EXCEPT WHERE NOTEDOTHERWISE. ALL WIRING SHALL BE STRANDED.

.2 A MINIMUM CONDUCTOR SIZE OF #12 AWG COPPER IS TO BE USED, EXCEPTWHERE NOTED OTHERWISE.

.3 ALL CONDUCTORS ARE TO BE COLOR CODED PER THE CANADIANELECTRICAL CODE.

.4 ALL WIRING AND CABLING IN EXPOSED OR OPEN CEILING AREAS IS TO BEINSTALLED IN EMT CONDUIT.

.5 ALL WIRING AND CABLING IN EXTERIOR INSTALLATIONS SHALL BE INSTALLEDIN GALVANIZED RIGID STEEL.

.6 ARMOURED CABLE MAY ONLY BE UTILIZED FOR THE FOLLOWING:- DROPS TO INDIVIDUAL LUMINAIRES AND SHALL HAVE A MAXIMUM LENGTH

OF 1.5m. DAISY-CHAINING OF LUMINAIRES IS NOT PERMITTED.- FINAL CONNECTION TO MOTORS, TRANSFORMERS OR VIBRATING

EQUIPMENT.SUCH INSTALLATIONS ARE TO BE INSTALLED PARALLEL TO STRUCTURALLINES IN A NEAT AND TIDY MANNER.

21. WIRING DEVICES & BOXES

.1 ALIGN ALL DEVICES AND PLATES PLUMB AND LEVEL WITH BUILDINGSTRUCTURAL LINES.

.2 ALL OUTLET BOXES ARE TO BE FLUSH MOUNTED EXCEPT WHERE SPECIFIEDOTHERWISE.

.3 ALL JUNCTION BOXES ARE TO HAVE VISIBLE P-TOUCH LABELS INDICATINGTHE CIRCUIT NUMBERS UTILIZED; PEN OR FELT IS NOT ACCEPTABLE.

.4 SUPPLY AND INSTALL BLANK COVER PLATES FOR ALL UNUSED JUNCTIONBOXES, INCLUDING EXISTING.

22. LOCATION OF OUTLETS

.1 THE ENGINEER RESERVES THE RIGHT TO CHANGE THE LOCATION OFOUTLETS TO WITHIN 3 M OF POINTS INDICATED ON PLANS WITHOUT EXTRACHARGE, PROVIDED THE ELECTRICAL CONTRACTOR IS ADVISED BEFOREINSTALLATION IS MADE.

.2 ELECTRICAL TRADE TO REFER TO ARCHITECTURAL ROOM ELEVATIONS FORPOSITIONS, AND MOUNTING HEIGHTS OF ALL OUTLETS, SWITCHES,INTERCOMMUNICATION, TELEPHONES, SPEAKERS, CLOCKS, ETC. POSITIONSSHOWN ON ARCHITECTURAL PLANS TO TAKE PRECEDENCE OVER POSITIONSOR MOUNTING HEIGHTS SHOWN ON ELECTRICAL PLANS.

23. SWITCHES AND RECEPTACLES

.1 ALL SWITCHES AND RECEPTACLES SHALL BE COMMERCIAL GRADE. MATCHEXISTING STANDARD WHERE STANDARD IS PRESENT. WHERE NO STANDARDIS PRESENT, PROVIDE WHITE DECORA SWITCHES AND RECEPTACLES ANDWHITE DECORA FACEPLATES.

.2 PROVIDE P-TOUCH LABELS FOR ALL RECEPTACLE LABELS.

.3 FOR ALL RECEPTACLES OTHER THAN STANDARD 15A DUPLEX RECEPTACLES,PROVIDE LAMACOID NAMETAGS GIVING AMP RATING, PHASE AND VOLTAGE.

.4 GROUND FAULT CIRCUIT INTERRUPTING (GFI) DUPLEX RECEPTACLES SHALLBE COMMERCIAL GRADE.

.5 ISOLATED GROUND (IG) RECEPTACLES SHALL BE COMMERCIAL GRADE.

.6 ALL RECEPTACLES OF CSA CONFIGURATION 5-15R AND 5-20R SHALL BETAMPER RESISTANT TYPE INSTALLED IN THE FOLLOW IN

LOCATIONS/FACILITIES:

- CHILD CARE FACILITIES- GUEST ROOMS AND SUITS OF HOTELS AND MOTELS- PRESCHOOL AND ELEMENTARY EDUCATION FACILITIES- DWELLING UNITS.

25. SUPPORTS

.1 ALL CONDUIT, RACEWAYS, AND OTHER ELECTRICAL EQUIPMENT SHALL BESECURELY AND ADEQUATELY SUPPORTED, IN ACCORDANCE WITH THECANADIAN ELECTRICAL CODE.

.2 WHERE INSERTS ARE REQUIRED IN CONCRETE, EXPANSION INSERTS, LEADINSERTS OR PLASTIC INSERTS ARE TO BE USED IN DRILLED HOLES. SHOTDRIVEN PINS MAY BE USED IN STRUCTURAL CONCRETE ONLY WITH THEPERMISSION OF THE ELECTRICAL CONSULTANT.

26. GROUNDING AND BONDING

.1 A COMPLETE GROUNDING AND BONDING SYSTEM SHALL BE SUPPLIED ANDINSTALLED IN ACCORDANCE WITH THE CANADIAN ELECTRICAL CODE ANDTHE ELECTRICAL INSPECTION DEPARTMENT.

.2 ALL METAL PARTS NOT CARRYING CURRENT, INCLUDING BUT NOT LIMITEDTO, SECONDARY FEEDER CIRCUITS, EQUIPMENT AND PANELBOARDENCLOSURES, METAL RACEWAYS, PULL AND JUNCTION BOXES, SHALL BEPROPERLY BONDED. METAL RACEWAYS SHALL UTILIZE DOUBLE LOCKNUTSAND OTHER FITTINGS WHERE NECESSARY TO PROVIDE BOND CONTINUITY.

.3 A SEPARATE BOND CONDUCTOR SHALL BE INSTALLED IN ALL RACEWAYFEEDER RUNS, FLEXIBLE CONDUIT, AND IN CONDUIT INSTALLED IN SLAB ORUNDERGROUND.

.4 THIS CONTRACTOR IS RESPONSIBLE FOR THE BOND OF ALL THE EQUIPMENTRACKS IN THE SERVER ROOM, THE CABLE TRAY, ELECTRICAL EQUIPMENTAND ANY CONDUIT. ALL GROUNDING OF SERVER RACKS MUST BE INACCORDANCE TO MANUFACTURERS GUIDELINES AND RECOMMENDATIONS.

27. PANELS

.1 PROVIDE COMPLETE PANELBOARDS. UNLESS OTHERWISE INDICATEDPANELBOARDS ARE TO BE 120/208V, 3PH, 4W OR 347/600V, 3Ø, 4W SOLIDNEUTRAL DESIGN WITH SEQUENCE STYLE BUSSING AND FULL CAPACITYNEUTRAL WITH BOLT-ON CIRCUIT BREAKERS. WHERE DOUBLE NEUTRALSARE INDICATED ON THE SINGLE LINE DIAGRAM, PROVIDE 200% RATEDNEUTRAL PANELBOARDS.

.2 PROVIDE ALL CIRCUIT BREAKERS INDICATED PLUS A MINIMUM OF 2x15A 1PSPARES IN EACH PANEL. CIRCUIT BREAKERS TO BE RATED MINIMUM 25kA I.C.UNLESS OTHERWISE INDICATED AND BE SERIES RATED.

.3 PANELS ARE TO BE FLUSH MOUNTED IN PUBLIC AREAS AND SURFACEMOUNTED IN SERVICE ROOMS, ALL COMPLETE WITH ALL TRIM, LOCKABLEDOORS AND INSTALLATION HARDWARE. PROVIDE DRIP SHIELDS IN AREASWITH SPRINKLERS.

.4 UPDATED TYPEWRITTEN PANEL DIRECTORIES SHALL BE PROVIDED FOR ALLPANELS.

.5 UTILIZE EXISTING PANELBOARDS AS INDICATED ON THE DRAWING. REUSEEXISTING BREAKERS WHERE POSSIBLE. PROVIDE NEW BREAKERS ASREQUIRED.

.6 BALANCE PANEL LOAD FOR EACH PHASE A, B, & C. ALLOW FOR RELOCATINGCIRCUITS WITHIN PANEL BOARD TO BALANCE THE LOAD.

28. LIGHTING LUMINAIRES AND LIGHTING CONTROLS

.1 PROVIDE A NEW LIGHTING SYSTEM, COMPLETE AND FULLY OPERATIONALAND IN CONFORMANCE WITH CODE AND ULC LISTING REQUIREMENTS.UNLESS NOTED OTHERWISE, ALL FIXTURES AND LAMPS ARE TO BESUPPLIED AND INSTALLED BY THE CONTRACTOR AS SPECIFIED IN THEDRAWINGS.

.2 ELECTRICAL TRADE TO INSTALL ALL LIGHTING LUMINAIRES COMPLETE WITHLAMPS, MOUNTING BRACKETS, BALLASTS AND ALL NECESSARYACCESSORIES IN ACCORDANCE WITH THE LUMINAIRE TYPES SHOWN ON THEDRAWINGS, OR OTHERWISE SPECIFIED.

.3 ALL LUMINAIRES SHALL BE ALIGNED, AS APPROPRIATE, WITH ONE ANOTHERAND WITH STRUCTURAL LINES.

.4 ALL LUMINAIRES SHALL BE CLEANED AND LAMPED UPON COMPLETION OFWORK AND PRIOR TO FINAL ACCEPTANCE. UTILIZE MANUFACTURER'SAPPROVED OR RECOMMENDED CLEANING SOLUTIONS.

.5 WHERE NO SWITCH IS INDICATED ON THE DRAWINGS FOR LIGHTING INPUBLIC AREAS OF THE BUILDING, THE LUMINAIRES SHALL BE SWITCHEDFROM THE PANEL. BREAKERS USED FOR SUCH SWITCHING SHALL BESWITCH RATED.

.6 SWITCHES SHALL HAVE A CURRENT RATING NOT LESS THAN THAT OF THECIRCUIT TO WHICH THEY ARE CONNECTED.

.7 ELECTRICAL TRADE TO SUPPLY AND INSTALL ALL LIGHTING CONTROLS WITHLINE VOLTAGE SWITCHES, DIMMER SWITCHES (RATED 1500W), LOWVOLTAGE SWITCHES, LIGHTING RELAYS, BARRIER AND ALL CONTROL WIRINGAND COMPONENTS TO SUIT THE LAYOUT. ALL MATERIALS AND INSTALLATIONSHALL BE IN ACCORDANCE WITH THE RECOMMENDATION OF THEMANUFACTURER AND COMPLY WITH CODES.

.8 LOW VOLTAGE MASTER SWITCHES AND BUILDING LIGHTING CONTROL SHALLHAVE THE CAPABILITY TO TURN ON AND OFF ALL LIGHTING (120 AND 347VOLT) WITH THE EXCEPTION OF LUMINAIRES ON EMERGENCY LIGHTINGCIRCUITS OR UNSWITCHED NIGHT LIGHT CIRCUITS.

.9 COORDINATE LIGHTING CONTROL PROGRAMMING WITH THE BUILDINGSUPERVISOR.

.10 ALL NEW AND RELOCATED FLUORESCENT LUMINAIRES SHALL BE COMPLETEWITH A FLUORESCENT DISCONNECT SWITCH AS PER CEC RULE 30-308(4).FLUORESCENT DISCONNECT SWITCH SHALL BE THOMAS AND BETTSMARRETTE FLUORESCENT LUMINARE DISCONNECT LD2C AND LD3C ORAPPROVED EQUAL. FLUORESCENT DISCONNECT SWITCH SHALL BE FACTORYINSTALLED AND CSA APPROVED.

29. LIGHTING CONTROLS COMMISSIONING REQUIREMENTS

.1 FUNCTIONAL TESTING OF LIGHTING CONTROL DEVICES AND LIGHTINGCONTROL SYSTEMS SHALL BE COMPLETED TO ASHRAE 90.1 - 2016REQUIREMENTS AND BY A THIRD PARTY. THE FOLLOWING ITEMS SHALL BEINCLUDED BUT NOT LIMITED TO, IN THE TESTING:

· CONFIRM THAT THE HARDWARE AND SOFTWARE IS CALIBRATED, ADJUSTED,PROGRAMMED AND IN PROPER WORKING CONDITION IN ACCORDANCE WITHTHE CONSTRUCTION DOCUMENTS AND MANUFACTURERS INSTALLATIONSINSTRUCTIONS.

· CONFIRM THAT THE PLACEMENT, SENSITIVITY AND TIME-OUT ADJUSTMENTSFOR OCCUPANCY SENSORS YIELD ACCEPTABLE PERFORMANCE, LIGHTSTURN OFF ONLY AFTER SPACE IS VACATED AND DO NOT TURN NON UNLESSSPACE IS OCCUPIED.

· CONFIRM THAT THE TIME SWITCHES AND PROGRAMMED SCHEDULECONTROLS ARE PROGRAMMED TO DIM THE LIGHTS OR TURN THE LIGHTSOFF.

· CONFIRM THAT PHOTO-SENSOR (DAYLIGHT SENSOR) CONTROLS REDUCEELECTRIC LIGHT LEVELS BASED ON THE AMOUNT OF USABLE DAYLIGHT INTHE SPACE AS SPECIFIED.

.2 THE CONTRACTOR SHALL RETAIN AND PAY FOR A THIRD PARTYRESPONSIBLE FOR THE FUNCTIONAL TESTING. THE THIRD PARTY SHALL NOTBE INVOLVED IN EITHER THE DESIGN OR CONSTRUCTION OF THE PROJECTAND SHALL PROVIDE DOCUMENTATION CERTIFYING THAT THE INSTALLEDLIGHTING CONTROLS MEET OR EXCEED ALL DOCUMENTED PERFORMANCECRITERIA FOR EACH SPACE. THE COMMISSIONING DOCUMENTATION SHALLLIST EACH INDIVIDUAL ROOM AND SPACE WITH CONFIRMATION OF EACHTYPE OF CONTROL.

.3 THE THIRD PARTY WHO WILL CONDUCT AND CERTIFY THE FUNCTIONALTESTING, SHALL BE AN EXPERIENCED LIGHTING CONTROL SPECIALIST OR AREGISTERED PROFESSIONAL.

.4 IF ANY ROOM OR SPACE IS FOUND TO FAIL DURING THE FUNCTIONALTESTING, THE CONTRACTOR SHALL CALIBRATE, ADJUST AND PROGRAM ALLCONTROLS AS REQUIRED TO ENSURE THAT EACH ROOM AND SPACE IS INPROPER WORKING CONDITION IN ORDER TO PASS THE COMMISSIONING.

30. SEISMIC PROTECTION

.1 THE ELECTRICAL TRADE SHALL PROVIDE SEISMIC RESTRAINT ANDANCHORAGE FOR ALL EQUIPMENT AND SERVICES IN ACCORDANCE WITHTHE CURRENT EDITION OF THE B.C. BUILDING CODE, ECA SEISMICRESTRAINT MANUAL AND ALL APPLICABLE BUILDING BYLAWS.

.2 IF REQUESTED PROVIDE CERTIFIED PROFESSIONALLY SEALED SHOP ANDPLACEMENT DRAWINGS WHERE APPLICABLE FOR ALL ELECTRICALEQUIPMENT AND EQUIPMENT ASSEMBLIES SHOWING THE METHODS OFATTACHMENT TO THE PARTICULAR STRUCTURE FOR EACH PIECE OFEQUIPMENT AND ASSEMBLY AND PROVIDE ANCHORAGE/ATTACHMENTDETAILS APPROVED AND SEALED BY A B.C. REGISTERED PROFESSIONALENGINEER.

.3 INCLUDE IN THE TENDERED PRICE ALL SERVICES OF A PROFESSIONALENGINEER INCLUDING BUT NOT LIMITED TO PROVIDING LETTERS OFASSURANCE FOR THE PROJECT IN RESPECT OF THE SEISMIC RESTRAINT OFALL ELECTRICAL MATERIALS AND EQUIPMENT, CONDUCTING THENECESSARY SITE REVIEWS AND PROVIDING A LETTER AT THE CONCLUSIONOF THE PROJECT, CONFIRMING THAT ALL SEISMIC RESTRAINTS FOR THEELECTRICAL WORKS HAVE BEEN INSTALLED IN ACCORDANCE WITH THEENGINEER'S INSTRUCTIONS. PAY ALL ASSOCIATED FEES AS REQUIRED. THESEISMIC ENGINEER SHALL BE IN GOOD STANDING WITH EGBC AND CARRY APROFESSIONAL LIABILITY INSURANCE OF 1 MILLION DOLLARS. SEISMICENGINEER SHALL PROVIDE PROOF OF INSURANCE AND CREDENTIALS IFREQUESTED.

31. COMMUNICATIONS (VOICE, DATA & TV) & SECURITY ROUGH-IN

.1 NO CONDUIT RUN SHALL EXCEED TWO 90 DEGREE BENDS AND ONE 45DEGREE SWEEPING BEND.

.2 ALL COMMUNICATION BACKBOARDS ARE TO BE 21mm THICK, G1S, ANDPAINTED WITH FIRE RETARDANT PAINT TO MATCH COLOR OF THE ROOM.

.3 THE INSTALLATION OF COMMUNICATIONS EQUIPMENT, AND CONDUIT TO BEUSED FOR COMMUNICATION WIRES, SHALL COMPLY IN ALL RESPECTS WITHTHE REQUIREMENTS OF TELUS AND SHAW AND TO EIA/TIATELECOMMUNICATION STANDARDS.

.4 PROVIDE DOUBLE GANG BOX C/W SINGLE GANG MUD RING, OUTLET BOXESAND EMPTY CONDUITS C/W PULL STRING FOR COMMUNICATIONS OUTLETSAS SHOWN ON THE DRAWINGS.

.5 INSTALL 3/4" EMT CONDUITS FROM EACH WALL OR FLOOR MOUNTEDCOMMUNICATION OUTLET (UNLESS NOTED OTHERWISE) TO THE ACCESSIBLECEILING SPACE ABOVE C/W BUSHING AT BOTH ENDS.

32. IDENTIFICATION

.1 IDENTIFY ALL MAJOR PIECES OF EQUIPMENT, INCLUDING BUT NOT LIMITEDTO PANELBOARDS, ELECTRICAL CABINETS, AND BREAKERS INPANELBOARDS WITH ENGRAVED LAMACOID LABELS, BLACK LETTERING ONWHITE BACKGROUND.

.2 PROVIDE TYPEWRITTEN DIRECTORIES IN ALL PANELS.

.3 PROVIDE LAMACOID NAMEPLATE ON EACH PANEL COVER TO IDENTIFYPANEL NAME, NUMBER OF PHASES, VOLTAGE, CURRENT RATING ANDSOURCE OF FEEDER.

.4 IDENTIFY BRANCH CIRCUIT WIRES TO MEET CODE REQUIREMENTS.

.5 FIRE ALARM BREAKER TO BE PAINTED RED AND CLEARLY IDENTIFIED.

33. ALTERNATES

.1

.2

ALL REQUESTS FOR ALTERNATES SHALL BE SUBMITTED TO THE ELECTRICAL CONSULTANT NOT LESS THEN 5 DAYS PRIOR TO THE CLOSE OF RFP.

THE ELECTRICAL CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ENSURING THAT ALTERNATE PRODUCTS MEET ALL SPACE, WEIGHT, CONNECTION, POWER, WIRING, AND PERFORMANCE REQUIREMENTS.

34. POWER DISTRIBUTION

.1 INSTALL A COMPLETE POWER DISTRIBUTION SYSTEM INCLUDINGUNDERSLAB CONDUIT, SERVICE CONNECTIONS, GROUNDING, DISTRIBUTIONEQUIPMENT, AND PANELBOARDS.

35. FIRE STOP

.1 AFTER INSTALLATION OF THE ELECTRICAL, ALL PENETRATIONS OF FIRERATED ASSEMBLIES FOR CONDUITS, SLEEVES, CABLE TRAYS, POKETHRU'SETC. SHALL BE FIRE STOPPED USING A FIRE STOPPING ASSEMBLY,MATERIAL AND METHODS THAT MEET THE REQUIREMENTS OF CAN/ULC-S115AND INSTALLED ACCORDING TO MANUFACTURER'S SPECIFICATIONS. THEFIRE STOP MATERIAL SHALL ALLOW FOR RE-ENTERABLE ACCESS. BEFOREINSTALLATION, CONTRACTOR SHALL IDENTIFY A FIRE STOPPING SYSTEMSUITABLE FOR THE INSTALLATION AND SUBMIT APPLICABLE SHOPDRAWINGS TO ELECTRICAL CONSULTANT FOR REVIEW. ALLOW FOR 2%DESTRUCTIVE TESTING OF THE FIRE STOPPING INSTALLATION.

.2 LABEL FIRE STOP PENETRATIONS WITH PRODUCT USED AND cUL SYSTEMNUMBER WITH STICKER.

36. SERVICE ENTRANCE

.1 MAIN SWITCH AND FUSES TO BE RATED AS PER DRAWINGS.

37. UNDERGROUND SERVICES

.1 ELECTRICAL CONTRACTOR TO PROVIDE SECONDARY DUCT IN ACCORDANCEWITH BC HYDRO REGULATIONS.

.2 IF NOT OTHERWISE NOTED ON THE DRAWINGS, PROVIDE THREE 103mmSERVICE CONDUITS FROM TELEPHONE AND CABLE BACKBOARDS TOPROPERTY LINE FOR TELEPHONE AND CABLE TV SERVICE.

.3 INCLUDE ALL COSTS FOR UTILITY CONNECTIONS CHARGES IN THISCONTRACT.

.

1 ISSUED FOR 75% REVIEW 25/02/2021

NOT FOR CONSTRUCTION

AS NOTED 22/02/2020 ZC MK

20-087 3

1. THE COPYRIGHT OF THIS DRAWING IS VESTED IN O'M ENGINEERINGINC. AND IT MAY NOT BE REPRODUCED IN WHOLE OR PART OR USEDFOR THE MANUFACTURE OF ANY ARTICLE WITHOUT THE EXPRESSPERMISSION OF THE COPYRIGHT HOLDERS.

2. WORK TO FIGURED DIMENSIONS ONLY.

3. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANTARCHITECT'S, SERVICE ENGINEER'S AND O'M ENGINEERING INC.DRAWINGS AND SPECIFICATIONS.

SHEFFIELD PARK3510 SHEFFIELD AVENUECOQUITLAM, BCV3E 3H1

CITY OF COQUITLAM

N

2 ISSUED FOR BUILDING PERMIT R1

3 ISSUED FOR 95% REVIEW 18/03/2021

LANDSCAPE ARCHITECT:

ARCHITECT:

10/03/2021

22/04/20214---- --/--/----5ISSUED FOR RFP

E04

ELECTRICAL SPECIFICATIONS

AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESCRIPTION:
AutoCAD SHX Text
REV:
AutoCAD SHX Text
Notes:
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
PROJECT NO:
AutoCAD SHX Text
DRAWING NO:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
SCALE AT A0:
AutoCAD SHX Text
STATUS:
AutoCAD SHX Text
PROJECT NAME/ADDRESS:
AutoCAD SHX Text
CLIENT:
AutoCAD SHX Text
DRAWING TITLE:
AutoCAD SHX Text
PROJECT NORTH: