Dr. Jens Voigt Technische Universität München 2008 · Dispense Systems other DIN Standards •...

23
1 24.10.2008 Dr. Jens Voigt TUM Weihenstephan Dr. Jens Voigt Technische Universität München 2008 STANDARDS for DRAFT DISPENSE (DIN NORM 6650) Draft Beer Hygiene 24.10.2008 Dr. Jens Voigt TUM Weihenstephan

Transcript of Dr. Jens Voigt Technische Universität München 2008 · Dispense Systems other DIN Standards •...

1

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

Dr. Jens VoigtTechnische Universität München

2008

STANDARDS for DRAFT DISPENSE

(DIN NORM 6650)

Draft Beer Hygiene

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

2

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

Why Norms & Standards?

• Goals:

- assure position of economy- strategic directives- support national laws and rules- have technical convergence- create efficient control processes and instruments

Quelle: www.din.de , „Arbeiten mit Normen“

3

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

Standards for Dispense Systems

• TRSK• DIN• BG-Rules• EU-regulations

• remaining TRSK transition into BG-Rules• Norms & Standards shall be „state-of-the-art“• Norm can become legal guidelines or laws or law-like

instructions/regulations

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

Series DIN 6650 Beverage Dispense Plants

• DIN 6650-1 General Requirements• DIN 6650-2 Material Requirements• DIN 6650-3 Safety Requirements of Parts• DIN 6650-4 Hygienic Requirements of Parts and components• DIN 6650-5 Test Methods and Procedures• DIN 6650-6 Cleaning and Disinfection• DIN 6650-7 Hygienic Requirements for Installation of Plants

and Units• DIN 6650-8 Water Dispense Units line-connected – Point of use

(PoU) (in preparation)• DIN 6650-9 Water Dispense Units, free-standing– Watercooler

(in preparation)

4

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

Other Standards for Cylindrical Beverage Containers

• DIN 6647-1 nominal Volume < 50 Litermax. allowed operating overpressure < 3 bar

• DIN 6647-2 nominal volume < 50 Litermax. allowed operating overpressure < 7 bar

• DIN 6647-3 Beverage and base materialmax. allowed operating overpressure < 3 bar, Nominal Volume > 100 l

• DIN 6647-4 Beverage and base materialmax. allowed operating overpressure < 3 bar, Nominal Volume < 60 l

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

Dispense Systems other DIN Standards

• DIN 6653-1 Beverage and concentrate – Parts (tubes, lines)• DIN 6653-2 Parts : Requirements for operation and testing of

CO2 warning devices• DIN 6653-3 Manual Glas Rinsing Devices• DIN 3542 Keg/Conainer connectors• DIN 32677 Pipe/Tube/Hose connectors• DIN 8546 Pressure Reducing Devices

• DIN VDE 0100 Rules for High voltage installations < 1000 V• DIN VDE 0105-100 Operation of Electrical Plants• DIN 10503, DIN 32677, [...], • ........

5

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

Food Hygiene Regulation, National/European Law(Lebensmittelhygiene Verordnung EU) 2004

• No negative influencesno disgust causing- microbiological- smell, gases, aerolsols- human or animal excretions- pests- effluents, wastes

• No dangerous food handlingSafety concept & hazard analysis

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

What is a DIN-Norm?

6

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

DIN 6650-4

Dispensing Plants:Hygiene Requirements for Parts

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

DIN 6650-4: Hygiene Requirements

General:• Design to avoid

ContaminationMicroorganismsIndentation, dead ends cravices, sharp edgesFlows to be drainable

• Surfacessmooth, even for easy drainingcleanability

7

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

• Dirt: all contaminations able to cause negative effects in parts or product

• Cleaning: Removal of Dirt

• Easy-to-clean DesignHygienic Design:

Cleanability with simple meansreliable

DIN 6650-4: Hygiene Requirements

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

Centric Connectors. No gaps, dead areas!

1 Nut2 Metallic contact, defined pressing3 Zentric

1 Nut2 axial Pressing, radiale seal3 Gap, dead area

Risk!Suggestion

8

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

Risk rightgapedge

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

DIN 6650-6

Dispense Systems:Requirements for Cleaning and

Disinfection

9

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

DIN 6650-6: Requirements for Cleaning and Disinfection

TargetCleaning IntervalsCleaning methodsCleaning agents

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

DIN 6650-6: Requirements for Cleaning and Disinfection

Beverages aIntervalls b

days

Fruit juices, nectares

Still Water (< 4g CO2/l), non-alc. beers

Wine; carbonated non-alc. beverages, carbonated waterBeer (except non-alc. Beers)

Concentrates, Spririts

a in mixes lowest intervall relevantb validate test requirements a) to f) according to Section 7 for exceeded intervals

11 to 7

7

7 to 14

30 to 90

10

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

Other minimal Cleaning requirements:

• Prior to first commissioning• Before/after usage interruptions > one week• Before every change of product• Parts in contact with air and product (e.g. taps, drip

plates...) daily!• Connection parts before each use at another beverage

container/keg

Who does this really???

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

Contamination indicators:

• Residues, settlements, films• Untypical smells• sensoric deviations• Other unusual appearances

e.g. fungus, moldhaze in clear liquidsSlime/Biofilm layers on fittings and armatures

11

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

DIN 6650-6

Cleaning Processes - General:• [...] mechanical cleaning methods to be combined with

chemical cleaning or disinfection

• Mechanical cleaning can NOT remove microbiologicalcontamination or kill microbes.

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

Chemical Cleaning:

• Chemical cleaning has to be able to remove/dissolvelayers and enable steps of disinfection for killing of microbes.

12

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

DIN 6650-6: Cleaning Requirements

Control of Cleaning effects:

• Available Methods :

a) Visual examination for visible contaminationb) mechanical Test methods [...]c) chemical Test methods [...]d) Sensorical Tests (z. B. smell, flavour)e) Mikrobiological culture test method in drafted beverages.

Total culture count: < 1000 cfu/ml ~OK

> 50.000 cfu/ml BAD> 10.000 cfu/ml Cleaning recommended

Colony forming unitsf) Non-cultural Test methods (e.g. ATP-Methods)

• For the control of cleaning tests a) to d) are minmal requirements• Test e) and or f) may be used to describe the status of plants

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

DIN 6650-6

Requirements for Cleaning/disifection agentsGeneral:

• To be completely removable• To be effective and material compatible

• Appropriate for the use• Safety, health and environmental information from the

supplier to be available• Compliance with food safety regulations

13

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

DIN 6650-6

Cleaning and Disinfection

• Parts and lines to be completely drained• Cleaning and operation instructions to be obeyed• Single use of sponge balls• [...]• Warning at tap, if liquids can be taken during cleaning!!

Thourough rinsing of parts and lines with potable wateruntil no visual indicationsuntil no detergents traceable

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

DIN 6650-6

Certification of Cleaning or Disifection

- Cleaning or disinfection processes must beconfirmed by performing person

Automated Protocolls are aceptable.

Documentation in a plant record necessary.

Documentation to be available at the plant.

14

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

DIN 6650-7

Hygienic Requirements for Installationsand Plants

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

• Rooms– Floor condition– Potable Water supply– Avoiding of negative influences

• Requirements for storage cabinets and rooms

- Cleanbility!- Protection against liquids- Lighting

DIN 6650-7: Requirements for plants

15

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

DIN 6650-7: Requirements for plants

• Includes all parts from storage to tap and also cleaninginstallations

• Hygienic Certificates required

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

• Documentation– Supplier or Installer,– Date,– Description of Plant– Notes about non-standard equipment– Cleaning instructions– Service and Maintanance instructions– Note about Cleaning after Installation.

DIN 6650-7: Requirements for plants

16

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

17

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

18

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

19

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

20

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

21

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

22

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

Conclusions

• Standards are needed to create benchmarks

• They can create more safety• They can create more hygiene

• Consumer protection• They support our business and consumer behaviour

• Follow standards and give feedback!

23

24.10.2008 Dr. Jens Voigt TUM Weihenstephan

Thank You!

Dr. Jens VoigtTU München-Weihenstephan

[email protected]

+49 8161 71 3179+49 172 8234 270