dpc-2004 kamaraj

3

Click here to load reader

description

GH

Transcript of dpc-2004 kamaraj

Format to be filled by the Executives appearing for DPC July 2003

Format to be filled by the Executives appearing for DPC July 2004

Name R.N.KAMARAJ

CPF No. 29829

Grade M1SDisciplineElectrical

Unit TPS-IIDivisionSwitchyard Maintenance

Qualification B.E. (Electrical & Electronics)

M.B.A . ; ICWAI (Inter)

DOB 06.04.1963 Age41

Past Experience:

Name of the UnitFromToNature of job performed

Thermal

Power Station-II09.12.198530.06.1988Operation and commissioning 230/400kVSwitchyard

Thermal

Power Station-II01.07.198801.05.1995Maintenance and commissioning of Units & Station DC sources, UPS batteries and automotive batteries

Thermal

Power Station-II02.05.199531.12.2002Maintenance, erection and commissioning of all Power & Service Transformers and High voltage rectifier transformers

Thermal

Power Station-II01.01.2003Till DateMaintenance of 230/400kV EHV Switchgear Equipments

Current Assignment with Date:

DATECURRENT ASSIGNMENT

01.01.2003Routine and Breakdown maintenance of all 230/400kV EHV Switchgear Equipments.

Procuring and implementation of approved project Replacement of 19 nos. of 245kV MOCBs with SF 6 Breakers in two phases.

Erection and commissioning of switchgear equipments viz. CTs, CVTs, LAs, Isolators etc.

Indenting and purchase of all EHV Switchgear equipment spares.

Maintaining of major equipments history.

DEC 2003Core team member, Internal Auditor & Lead Auditor for EQMS (ISO:9001 & 14001)

Contribution / Achievement (Tangible) made in the present post:

1. Proud to be a part of a team with Transport and MCT wing/RM Chennai which executed major cost saving (approx. Rs.15to 20 lakhs) following two assignments with the available NLC resources:

a) Intercarting and positioning of 250 MVA, 15/230kV Power transformer of 105T weight at North Madras Thermal Power Station, Chennai.

b) Intercarting and transporting of 250MVA, 15.75/400kV Power Transformer of 180T weight from Port Trust, Chennai to Thermal Power Station-II.

2. Execution of reinstallation and commissioning of repaired 15.75/400kV 250MVA Generator Transformer for UNIT-6.

3. Established the method for troubleshooting and rectification of High Voltage Rectifier Units of ESP Systems. It would have cost a minimum of Rs. 2 lakhs per HVR unit. This expenditure is saved with the help of the other divisions viz. MRT/TSII and CERS.

4. ST-1 and ST-2 radiators were started leaking heavily due to inherent deficiency. All these radiator bank gaskets were changed. Engaging of any external agency would have cost Rs.6 lakhs per transformer.

5. Successfully carried out the massive draining and filling with preprocessed EHV oil of 60KL in each GTs of Stage-I and of 30KL in ST-1 & ST-2.This has resulted in achieving of very high Insulation Resistance value of windings.

6. Successfully carried out overhauling and repair of 7 nos. of 400kV CVT, which are supposed to be carried out at manufacturers site.

7. By the way of maintaining 230kV Bahoor bay equipments at TSII end on behalf of PGCIL, likely to earn Rs.3 lakhs per year to our esteemed organization.

Suggestions:

1. Very keen in implementing the approved proposal of replacing all 19 nos. 245kV Minimum Oil Circuit Breakers with 245kV SF6 circuit breakers.

2. To continue the project of replacing the entire remaining GAP type 198kV Lightning arrestors with GAPLESS type lightning arrestors.3. To continue the project of replacing the conventional PG clamps with the state of art technology AMP Connectors to maximize the advantage of having very low contact resistance.4. Propose to introduce 0.2 Class accuracy CVTs and CTs, especially for Bus so as to have more accurate registering of Power transaction in Feeders / Units.5. Propose to do the retrofitting of 230kV isolators and its MOM Boxes to ensure safe and smooth reliable operations.6. Effective utilization of departmental labours Date: 20.06.2004 Signature

( R.N.KAMARAJ )