Downloaded from . Since 1968, RS Andrews …€¦ · • Two-stage gas valve operates on two-stage...

16
Product SPecificationS SS-AMV8 www.amana-hac.com 6/09 Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas. Supersedes 5/08 The Amana® brand AMV8/ADV8 two-stage, variable-speed multi-position, gas furnaces provide exceptional indoor comfort and quiet operation. With their two-stage gas valves and variable-speed circulator blowers, these furnaces provide comfort all season long. Standard Features Patented MillionAir™ stainless-steel, dual- diameter tubular heat exchanger with Lifetime Limited Unit Replacement Warranty* for as long as the original registered home- owner owns their home Two-stage gas valve operates on two-stage or single-stage thermostats Efficient and quiet variable-speed circulator motor gently ramps up or down according to heating or cooling demand SureStart™ Silicon Nitride igniter designed for long igniter life Furnace control board with self-diagnostics, color- coded low-voltage terminals, and provisions for electron- ic air cleaner and 120-volt or 24-volt humidifiers Low constant fan allows homeowner to activate very low speed to efficiently circulate air throughout the home. This setting costs as little as a 100-watt light bulb to operate. Quiet, two-speed induced draft blower All models comply with California NOx emissions standards Cabinet Features Fully insulated, heavy-gauge steel cabinet with durable baked-enamel finish Designed for multi-position installation: upflow, horizontal left or right Removable bottom for side- or bottom-return applications Convenient left or right connection for gas/electric service Coil and furnace fit flush for most installations Contents Nomenclature .................................................................................................... 2 Product Specifications .................................................................................. 3 Dimensions.......................................................................................................... 4 Performance Data ........................................................................................... 6 Wiring Diagrams .......................................................................................... 14 Accessories .........................................................................................................16 * To receive the Lifetime Heat Exchanger Limited Warranty, Lifetime Unit Replacement Limited War- ranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. Full warranty details available at www.amana-hac.com. amV8/adV8 two-Stage, Variable SPeed gaS furnace 80% afue Heating inPut: 70,000–115,000 btu/H Downloaded from www.rsandrews.com. Since 1968, RS Andrews has proudly served Atlanta's Heating, Air Conditioning & Plumbing Needs.

Transcript of Downloaded from . Since 1968, RS Andrews …€¦ · • Two-stage gas valve operates on two-stage...

Page 1: Downloaded from . Since 1968, RS Andrews …€¦ · • Two-stage gas valve operates on two-stage or single-stage thermostats • Effi cient and quiet variable-speed circulator motor

Product SPecificationS

SS-AMV8 www.amana-hac.com 6/09Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas. Supersedes5/08

The Amana® brand AMV8/ADV8 two-stage, variable-speed multi-position, gas furnaces provide exceptional indoor comfort and quiet operation. With their two-stage gas valves and variable-speed circulator blowers, these furnaces provide comfort all season long.

Standard Features• Patented MillionAir™ stainless-steel, dual-

diameter tubular heat exchanger with Lifetime Limited Unit Replacement Warranty* for as long as the original registered home-owner owns their home

• Two-stage gas valve operates on two-stage or single-stage thermostats

• Effi cient and quiet variable-speed circulator motor gently ramps up or down according to heating or cooling demand

• SureStart™ Silicon Nitride igniter designed for long igniter life• Furnace control board with self-diagnostics, color-

coded low-voltage terminals, and provisions for electron-ic air cleaner and 120-volt or 24-volt humidifi ers

• Low constant fan allows homeowner to activate very low speed to effi ciently circulate air throughout the home. This setting costs as little as a 100-watt light bulb to operate.

• Quiet, two-speed induced draft blower• All models comply with California NOx emissions standards

Cabinet Features• Fully insulated, heavy-gauge steel cabinet with durable

baked-enamel fi nish• Designed for multi-position installation: upfl ow,

horizontal left or right• Removable bottom for side- or bottom-return applications• Convenient left or right connection for gas/electric service• Coil and furnace fi t fl ush for most installations

ContentsNomenclature .................................................................................................... 2Product Specifi cations .................................................................................. 3Dimensions .......................................................................................................... 4Performance Data ........................................................................................... 6Wiring Diagrams .......................................................................................... 14Accessories .........................................................................................................16

* To receive the Lifetime Heat Exchanger Limited Warranty, Lifetime Unit Replacement Limited War-ranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. Full warranty details available at www.amana-hac.com.

amV8/adV8two-Stage, Variable SPeed

gaS furnace

80% afue

Heating inPut: 70,000–115,000 btu/H

Downloaded from www.rsandrews.com. Since 1968, RS Andrews has proudly served Atlanta's Heating, Air Conditioning & Plumbing Needs.

Page 2: Downloaded from . Since 1968, RS Andrews …€¦ · • Two-stage gas valve operates on two-stage or single-stage thermostats • Effi cient and quiet variable-speed circulator motor

Product SPecificationS

2 www.amana-hac.com SS-AMV8

nomenclature

Brand RevisionsA Amana® Brand A Initial Release

B 1st RevisionAirflow Direction C 2nd Revision

C Downflow/HorizontalD Dedicated DownflowH High Airflow NOxK Dedicated Upflow N Natural GasM Upflow/Horizontal X Low NOx

Description Cabinet WidthV Two-Stage/Variable-speed A 14”H Two-Stage/Multi-speed B 17½”S Single-Stage/Multi-speed C 21”

D 24½”

AFUE95 95% Maximum CFM @ 0.5” ESP9 90%+ 3 1,2008 80% 4 1,600

MBTU/h 5 2,000045: 45,000 115: 115,000070: 70,000 140: 140,000090: 90,000

9 11A

8B

10XM

21A V

33

5,6,748 70

Page 3: Downloaded from . Since 1968, RS Andrews …€¦ · • Two-stage gas valve operates on two-stage or single-stage thermostats • Effi cient and quiet variable-speed circulator motor

Product SPecificationS

SS-AMV8 www.amana-hac.com 3

SPecificationS

AMV8 0704BXB

AMV8 0905CXB

AMV8 1155CXB

ADV8 0703BXB

ADV8 0905CXB

ADV8 1155CXB

HeAting CApACity

High Fire Input (BTU/h)¹ 70,000 90,000 115,000 70,000 90,000 115,000

High Fire Output (BTU/h)¹ (below)

Natural Gas 57,000 74,000 93,000 57,400 73,600 92,000

LP Gas 49,000 64,000 82,000 49,252 64,246 85,961

Low Fire Input (BTU/h)¹ 52,500 67,500 86,000 52,500 67,500 86,000

Low Fire Output (BTU/h)¹ (below)

Natural Gas 42,000 54,000 69,000 42,000 54,000 69,000

LP Gas 42,000 54,000 69,000 43,096 55,409 70,595

AFUE2 80 80 80 80 80 80

Available AC @ 0.5” ESP 1.5 - 3.0 2.0 - 5.0 2.0 - 5.0 1.5 - 3.0 2.0 - 5.0 2.0 - 5.0

Temperature Rise Range (° F) 20 - 50 25 - 55 25 - 55 20 - 50 20 - 50 25 - 55

CirCulAtor Blower

Size (D x W) 10” x 8” 10” x 10” 10” x 10” 10” x 8” 10” x 10” 10” x 10”

Horsepower @ 1750 RPM ¾ ¾ ¾ ½ ¾ ¾

Speed Variable Variable Variable Variable Variable Variable

Vent Diameter¹ 4” 4” 4” 4” 4” 4”

No. of Burners 3 4 5 3 4 5

Disposable Filter Size (in2) 576 460 460 576 460 460

eleCtriCAl DAtA

Min. Circuit Ampacity³ 11.7 11.7 11.7 10.4 12.8 12.8

Max. Overcurrent Device (amps)4 15 15 15 15 15 15

Ship Weight (lbs) 152 178 194 156 182 202

1 Natural Gas BTU/h. For altitudes above 2,000’, reduce input rating 4% for each 1,000’ above sea level.2 DOE AFUE based upon Isolated Combustion System (ICS)3 Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with Na-

tional Electrical Codes. Extensive wire runs will require larger wire sizes.4 Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit

breakers of the same size as noted.

notes• All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.• Gas Service Connection ½” FPT• Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all

existing local codes.

Page 4: Downloaded from . Since 1968, RS Andrews …€¦ · • Two-stage gas valve operates on two-stage or single-stage thermostats • Effi cient and quiet variable-speed circulator motor

Product SPecificationS

4 www.amana-hac.com SS-AMV8

amV8 dimenSionS

minimum clearanceS to combuStible materialS

siDes reAr Front¹Vent²

topsw B

1 0 3 6 1 1

Approved for line contact in the horizontal position.¹ 24” clearance for serviceability recommended.² Single Wall Vent (SW) to be used only as a connector. Refer to the venting tables out-

lined in the Installation Manual for additional venting requirements.

MoDel w D H A B

AMV80704BXB 17½” 28” 39” 17½” 16”

AMV80905CXB 21” 28” 39” 21” 19½”

AMV81155CXB 21” 28” 39” 21” 19½”

� � � � � � � � � � �

� � � � � � � � � � � �

� � � � �

� � � � � � � � � � � �

� � � � � � � � � � � � � � � � � �

� � � � � � � � �

� � � � � � � �

� � � � � � � � � � � � � �

� � � � � � � � � � � � � � � � �

� � � � � � � � � � � � � � � �

� � � � �

� � � � � � �

� � � � � �

� � � � � �

� � � � �

� � � � � �

� � � � �

� � � � � �

� � � � � �

� � � � � �

� � � � � �

� � � � � �

� � � � � �

� � � � � � �

� � � �

� � � � �

�28”

39”

Page 5: Downloaded from . Since 1968, RS Andrews …€¦ · • Two-stage gas valve operates on two-stage or single-stage thermostats • Effi cient and quiet variable-speed circulator motor

Product SPecificationS

SS-AMV8 www.amana-hac.com 5

adV8 dimenSionS

minimum clearanceS to combuStible materialS

siDes reAr Front¹Vent²

topsw B

1 0 3 6 1 1

notesApproved for line contact in the horizontal position.¹ 24” clearance for serviceability recommended.² Single Wall Vent (SW) to be used only as a connector. Refer to the venting tables

outlined in the Installation Manual for additional venting requirements.

MoDel A B

ADV80703BXB 14” 12½”

ADV80905CXB 21” 19½”

ADV81155CXB 21” 19½”

COMPONENT IDENTIFICATION

6

ADV8*****XA

CABINET SIZE A B Non-CombustibleFloor base

ADV80703BX** 17-1/2 16 SBT17

ADV80905CX** 21 19-1/2 SBT21

ADV81155CX** 21 19-1/2 SBT21

All dimensions are in inches.

Gas Inlet

28"4 7/16"

8 5/8"

39"

B 19 5/8"

Low Voltage

High Voltage

Alt. Gas Inlet

1 15/16"

11 3/8"

A

Page 6: Downloaded from . Since 1968, RS Andrews …€¦ · • Two-stage gas valve operates on two-stage or single-stage thermostats • Effi cient and quiet variable-speed circulator motor

Product SPecificationS

6 www.amana-hac.com SS-AMV8

* Motor CFM maximum † Motor CFM minimumnotes

• These charts are for furnaces installed at 0’ - 2,000’. At higher altitudes, a properly de-rated unit will have the same temperature rise at a particular CFM, while the ESP at that CFM will be lower.

• THE INSTALLATION IS TO BE ADJUSTED TO OBTAIN A TEMPERATURE RISE WITHIN THE RANGE LISTED ON THE FURNACE NAMEPLATE.• Propane gas installations will have a high-stage rise approximately 4° lower than shown in the tables.

low-Stage cooling SPeedS — amV8

AMV80704BXB AMV80905CXB AMV81155CXBCoolingspeeD tAp

ADjust tAp

CFM @ .1” to .8” w.C. esp

CoolingspeeD tAp

ADjust tAp

CFM @ .1” to .8” w.C. esp

CoolingspeeD tAp

ADjust tAp

CFM @ .1” to .8” w.C. esp

AMinus (-) 361†

AMinus (-) 563†

AMinus (-) 563†

Normal 390 Normal 563† Normal 563†Plus (+) 429 Plus (+) 572 Plus (+) 572

BMinus (-) 468

BMinus (-) 644

BMinus (-) 644

Normal 520 Normal 715 Normal 715Plus (+) 572 Plus (+) 787 Plus (+) 787

CMinus (-) 644

CMinus (-) 819

CMinus (-) 819

Normal 715 Normal 910 Normal 910Plus (+) 787 Plus (+) 1,001 Plus (+) 1,001

DMinus (-) 819

DMinus (-) 1,053

DMinus (-) 1,053

Normal 910 Normal 1,170 Normal 1,170Plus (+) 1,001 Plus (+) 1,287 Plus (+) 1,287

HigH- or Single-Stage cooling SPeedS — amV8

AMV80704BXB AMV80905CXB AMV81155CXB

CoolingspeeD tAp

ADjust tAp

CFM @ .1” to .8” w.C. esp

CoolingspeeD tAp

ADjust tAp

CFM @ .1” to .8” w.C. esp

CoolingspeeD tAp

ADjust tAp

CFM @ .1” to .8” w.C. esp

AMinus (-) 540

AMinus (-) 720

AMinus (-) 720

Normal 600 Normal 800 Normal 800Plus (+) 660 Plus (+) 880 Plus (+) 880

BMinus (-) 720

BMinus (-) 990

BMinus (-) 990

Normal 800 Normal 1,100 Normal 1,100Plus (+) 880 Plus (+) 1,210 Plus (+) 1,210

CMinus (-) 990

CMinus (-) 1,260

CMinus (-) 1,260

Normal 1,100 Normal 1,400 Normal 1,400Plus (+) 1,210 Plus (+) 1,540 Plus (+) 1,540

DMinus (-) 1,260

DMinus (-) 1,620

DMinus (-) 1,620

Normal 1,400 Normal 1,800 Normal 1,800Plus (+) 1,540 Plus (+) 1,980 Plus (+) 1,980

amV8 Performance data

Page 7: Downloaded from . Since 1968, RS Andrews …€¦ · • Two-stage gas valve operates on two-stage or single-stage thermostats • Effi cient and quiet variable-speed circulator motor

Product SPecificationS

SS-AMV8 www.amana-hac.com 7

cooling-baSed continuouS fan – amV8

AMV80704BXB AMV80905CXB AMV81155CXB

Cooling speeD tAp

ADjust tAp

CFM @ .1” to .8” w.C. esp

CoolingspeeD tAp

ADjust tAp

CFM @ .1” to .8” w.C. esp

CoolingspeeD tAp

ADjust tAp

CFM @ .1” to .8” w.C. esp

A

Minus (-) 361†

A

Minus (-) 563†

A

Minus (-) 563†

Normal 361† Normal 563† Normal 563†

Plus (+) 370 Plus (+) 563† Plus (+) 563†

B

Minus (-) 403

B

Minus (-) 563†

B

Minus (-) 563†

Normal 448 Normal 616 Normal 616

Plus (+) 493 Plus (+) 678 Plus (+) 678

C

Minus (-) 554

C

Minus (-) 706

C

Minus (-) 706

Normal 616 Normal 784 Normal 784

Plus (+) 678 Plus (+) 862 Plus (+) 862

D

Minus (-) 706

D

Minus (-) 907

D

Minus (-) 907

Normal 784 Normal 1,008 Normal 1,008

Plus (+) 862 Plus (+) 1,109 Plus (+) 1,109

* Motor CFM maximum† Motor CFM minimum

notes:• These charts are for furnaces installed at 0’ - 4,500’. At higher altitudes, a properly de-rated unit will have the same temperature rise at a

particular CFM, while the ESP at that CFM will be lower.• THE INSTALLATION MUST BE ADJUSTED TO OBTAIN A TEMPERATURE RISE WITHIN THE RANGE LISTED ON THE FURNACE NAMEPLATE.• Propane gas installations will have a high-stage rise approximately 4° lower than shown in the tables.

During Auto-Comfort mode, the furnace ramps up to 50% of the demand for half a minute. It then ramps to 82% of the full cooling demand airflow and operates there for approximately 7½ minutes. The motor then steps up to the full demand airflow. This mode spends a half minute at 50% airflow OFF delay.

auto-comfort mode

amV8 Performance data (cont.)

Page 8: Downloaded from . Since 1968, RS Andrews …€¦ · • Two-stage gas valve operates on two-stage or single-stage thermostats • Effi cient and quiet variable-speed circulator motor

Product SPecificationS

8 www.amana-hac.com SS-AMV8

amV8 Performance data (cont.)Heating SPeedS

AMV80704BXB(rise rAnge: 20° - 50 °F)

AMV80905CXB(rise rAnge: 25° - 55°F)

HeAting speeD tAp

ADjust tAplow stAge

CFM ¹HigH stAge

CFM ¹ rise ˚F HeAting speeD tAp

ADjust tAp

low stAge CFM ¹

HigH stAge CFM ¹ rise ˚F

AMinus (-) 810 1,077 48

AMinus (-) 945 1,257 53

Normal 900 1,197 43 Normal 1,050 1,397 48Plus(+) 990 1,317 39 Plus(+) 1,155 1,536 43

BMinus (-) 900 1,197 43

BMinus (-) 1,035 1,377 48

Normal 1,000 1,330 39 Normal 1,150 1,530 43Plus(+) 1,100 1,463 35 Plus(+) 1,265 1,682 40

CMinus (-) 990 1,317 39

CMinus (-) 1,125 1,496 44

Normal 1,100 1,463 35 Normal 1,250 1,663 40Plus(+) 1,210 1,609 32 Plus(+) 1,375 1,829 36

DMinus (-) 1,080 1,436 36

DMinus (-) 1,215 1,616 41

Normal 1,200 1,596 32 Normal 1,350 1,796 37Plus(+) 1,320 1650* 29 Plus(+) 1,485 1,975 34

¹ @ .1” to .5” w.c. ESP * Motor CFM maximum † Motor CFM minimum

AMV81155CXB(rise rAnge: 25° - 55°F)

HeAting speeD tAp

ADjust tAplow stAge

CFM ¹HigH stAge

CFM ¹ rise ˚F

AMinus (-) 1,170 1,556 55Normal 1,300 1,729 49Plus(+) 1,430 1,902 45

BMinus (-) 1,215 1,616 53Normal 1,350 1,796 47Plus(+) 1,485 1,975 43

CMinus (-) 1,260 1,676 51Normal 1,400 1,862 46Plus(+) 1,540 2000* 41

DMinus (-) 1,373 1,825 47Normal 1,525 2000* 42Plus(+) 1,678 2000* 38

¹ @ .1” to .5” w.c. ESP * Motor CFM maximum† Motor CFM minimum

notes• These charts are for furnaces installed at 0’ - 4,500’. At higher al-

titudes, a properly de-rated unit will have the same temperature rise at a particular CFM, while the ESP at that CFM will be lower.

• The installation must be adjusted to obtain a temperature rise within the range listed on the furnace nameplate.

• Do not operate above .5” w.c. ESP in heating mode.• Propane gas installations will have a high-stage rise approxi-

mately 4° lower than shown in the tables.

Page 9: Downloaded from . Since 1968, RS Andrews …€¦ · • Two-stage gas valve operates on two-stage or single-stage thermostats • Effi cient and quiet variable-speed circulator motor

Product SPecificationS

SS-AMV8 www.amana-hac.com 9

amV8 temPerature riSe cHartBLOWER PERFORMANCE SPECIFICATIONS

15

3040

5060

7080

9011

012

010

013

014

015

0

100

90 80 70 60 50 40 30 20 10

OU

TP

UT

BTU

/HR

x 1

000

BTU

OU

TPU

T v

s T

EM

PE

RA

TUR

E R

ISE

CH

AR

TTEMPERATURE RISE

600

CFM

700

900 10

00 1100 12

00

1400

1600 18

00 2000 22

00 2400

CFM

FOR

MU

LAS

BT

U O

UTP

UT

= C

FM x

1.0

8 x

RIS

E

RIS

E =

B

TU

OU

TPU

T

1.08

÷ C

FM

800

Page 10: Downloaded from . Since 1968, RS Andrews …€¦ · • Two-stage gas valve operates on two-stage or single-stage thermostats • Effi cient and quiet variable-speed circulator motor

Product SPecificationS

10 www.amana-hac.com SS-AMV8

adV8 Performance data

HigH- or Single-Stage cooling SPeedS

ADV80703BXB ADV80905CXB ADV81155CXB

CoolingspeeD tAp

ADjust tAp

CFM¹ CoolingspeeD tAp

ADjust tAp

CFM¹ CoolingspeeD tAp

ADjust tAp

CFM¹

AMinus (-) 540

AMinus (-) 720

AMinus (-) 765

Normal 600 Normal 800 Normal 850Plus (+) 660 Plus (+) 880 Plus (+) 935

BMinus (-) 720

BMinus (-) 990

BMinus (-) 1,035

Normal 800 Normal 1,100 Normal 1,150Plus (+) 880 Plus (+) 1,210 Plus (+) 1,265

CMinus (-) 900

CMinus (-) 1,260

CMinus (-) 1,305

Normal 1,000 Normal 1,400 Normal 1,450Plus (+) 1,100 Plus (+) 1,540 Plus (+) 1,595

DMinus (-) 1,080

DMinus (-) 1,620

DMinus (-) 1,665

Normal 1,200 Normal 1,800 Normal 1,850Plus (+) 1,320 Plus (+) 1,980 Plus (+) 2000*

low-Stage cooling SPeedS

ADV80703BXB ADV80905CXB ADV81155CXB

CoolingspeeD tAp

ADjust tAp

CFM¹ CoolingspeeD tAp

ADjust tAp

CFM¹ CoolingspeeD tAp

ADjust tAp

CFM¹

AMinus (-) 351†

AMinus (-) 468

AMinus (-) 563†

Normal 390 Normal 520 Normal 563†Plus (+) 429 Plus (+) 572 Plus (+) 619

BMinus (-) 468

BMinus (-) 644

BMinus (-) 673

Normal 520 Normal 715 Normal 748Plus (+) 572 Plus (+) 787 Plus (+) 822

CMinus (-) 585

CMinus (-) 819

CMinus (-) 848

Normal 650 Normal 910 Normal 943Plus (+) 715 Plus (+) 1,001 Plus (+) 1,037

DMinus (-) 702

DMinus (-) 1,053

DMinus (-) 1,082

Normal 780 Normal 1,170 Normal 1,203Plus (+) 858 Plus (+) 1,287 Plus (+) 1,323

¹ @ .1” to .8” W.C. ESP* Motor CFM maximum† Motor CFM minimum

notes• These charts are for furnaces installed at 0’ - 4,500’. At higher altitudes, a properly de-rated unit will have the same temperature rise at a

particular CFM, while the ESP at that CFM will be lower.• THE INSTALLATION MUST BE ADJUSTED TO OBTAIN A TEMPERATURE RISE WITHIN THE RANGE LISTED ON THE FURNACE NAMEPLATE.• Propane gas installations will have a high-stage rise approximately 4° lower than shown in the tables.

Page 11: Downloaded from . Since 1968, RS Andrews …€¦ · • Two-stage gas valve operates on two-stage or single-stage thermostats • Effi cient and quiet variable-speed circulator motor

Product SPecificationS

SS-AMV8 www.amana-hac.com 11

cooling-baSed continuouS fan

ADV80703BXB ADV80905CXB ADV81155CXB

Cooling speeD tAp

ADjust tAp

CFM¹ CoolingspeeD tAp

ADjust tAp

CFM¹ CoolingspeeD tAp

ADjust tAp

CFM¹

A

Minus (-) 302

A

Minus (-) 403

A

Minus (-) 563†

Normal 336 Normal 448 Normal 563†

Plus (+) 370 Plus (+) 493 Plus (+) 563†

B

Minus (-) 403

B

Minus (-) 554

B

Minus (-) 580

Normal 448 Normal 616 Normal 644

Plus (+) 493 Plus (+) 678 Plus (+) 708

C

Minus (-) 504

C

Minus (-) 706

C

Minus (-) 731

Normal 560 Normal 784 Normal 812

Plus (+) 616 Plus (+) 862 Plus (+) 893

D

Minus (-) 605

D

Minus (-) 907

D

Minus (-) 932

Normal 672 Normal 1,008 Normal 1,036

Plus (+) 739 Plus (+) 1,109 Plus (+) 1,140

¹ @ .1” to .8” W.C. ESP * Motor CFM maximum† Motor CFM minimum

notes:• These charts are for furnaces installed at 0’ - 4,500. At higher altitudes, a properly de-rated unit will have the same temperature rise

at a particular CFM, while the ESP at that CFM will be lower.• THE INSTALLATION MUST BE ADJUSTED TO OBTAIN A TEMPERATURE RISE WITHIN THE RANGE LISTED ON THE FURNACE NAMEPLATE.• Propane gas installations will have a high-stage rise approximately 4° lower than shown in the tables.

adV8 Performance data (cont.)

Page 12: Downloaded from . Since 1968, RS Andrews …€¦ · • Two-stage gas valve operates on two-stage or single-stage thermostats • Effi cient and quiet variable-speed circulator motor

Product SPecificationS

12 www.amana-hac.com SS-AMV8

Heating SPeedS

ADV80703BXB(rise rAnge: 20° - 50°F)

ADV80905CXB(rise rAnge: 20° - 50°F)

HeAting speeD tAp

ADjust tAplow-stAge

CFM¹HigH-stAge

CFM¹rise ˚F

HeAting speeD tAp

ADjust tAplow-stAge

CFM¹HigH-stAge

CFM¹rise ˚F

AMinus (-) 720 958 ---

AMinus (-) 945 1,257 ---

Normal 800 1,064 49 Normal 1,050 1,397 48Plus(+) 880 1,170 44 Plus(+) 1,155 1,536 43

BMinus (-) 810 1,077 48

BMinus (-) 1,035 1,377 48

Normal 900 1,197 43 Normal 1,150 1,530 43Plus(+) 990 1,317 39 Plus(+) 1,265 1,682 40

CMinus (-) 900 1,197 43

CMinus (-) 1,125 1,496 44

Normal 1,000 1,330 39 Normal 1,250 1,663 40Plus(+) 1,100 1,463 35 Plus(+) 1,375 1,829 36

DMinus (-) 990 1,317 39

DMinus (-) 1,215 1,616 41

Normal 1,100 1,463 35 Normal 1,350 1,796 37Plus(+) 1,210 1,609 32 Plus(+) 1,485 1,975 34

¹ @ .1” to .5” w.c. ESP * Motor CFM maximum † Motor CFM minimum

ADV81155CXB(rise rAnge: 25° - 55°F)

HeAting speeD tAp

ADjust tAplow-stAge

CFM¹HigH-stAge

CFM¹rise ˚F

AMinus (-) 1,215 1,616 52Normal 1,350 1,796 47Plus(+) 1,485 1,975 43

BMinus (-) 1,260 1,676 51Normal 1,400 1,862 46Plus(+) 1,540 2000* 41

CMinus (-) 1,305 1,736 49Normal 1,450 1,929 44Plus(+) 1,595 2000* 40

DMinus (-) 1,418 1,885 45Normal 1,575 2000* 40Plus(+) 1,733 2000* 37

¹ @ .1” to .5” w.c. ESP * Motor CFM maximum † Motor CFM minimum

notes• These charts are for furnaces installed at 0’- 4,500’. At higher

altitudes, a properly de-rated unit will have the same tempera-ture rise at a particular CFM, while the ESP at that CFM will be lower.

• The installation must be adjusted to obtain a temperature rise within the range listed on the furnace nameplate.

• Do not operate above .5” w.c. ESP in heating mode.• Propane gas installations will have a high-stage rise approxi-

mately 4° lower than shown in the tables.

adV8 Performance data (cont.)

Page 13: Downloaded from . Since 1968, RS Andrews …€¦ · • Two-stage gas valve operates on two-stage or single-stage thermostats • Effi cient and quiet variable-speed circulator motor

Product SPecificationS

SS-AMV8 www.amana-hac.com 13

adV8 temPerature riSe cHartBLOWER PERFORMANCE SPECIFICATIONS

15

3040

5060

7080

9011

012

010

013

014

015

0

100

90 80 70 60 50 40 30 20 10

OU

TP

UT

BT

U/H

R x

100

0

BT

U O

UT

PU

T v

s T

EM

PE

RA

TU

RE

RIS

E C

HA

RT

TEMPERATURE RISE

600

CF

M 700

900 10

00 1100 12

00

1400

1600 18

00 2000 22

00 2400

CF

M

FO

RM

ULA

SB

TU

OU

TP

UT

= C

FM

x 1

.08

x R

ISE

RIS

E =

B

TU

OU

TP

UT

1.08

÷ C

FM

800

Page 14: Downloaded from . Since 1968, RS Andrews …€¦ · • Two-stage gas valve operates on two-stage or single-stage thermostats • Effi cient and quiet variable-speed circulator motor

Product SPecificationS

14 www.amana-hac.com SS-AMV8

amV8 wiring diagram

Wiri

ng is

sub

ject

to

chan

ge. A

lway

s re

fer

to t

he w

iring

dia

gram

on

the

unit

for t

he m

ost u

p-to

-dat

e w

iring

WA

RNIN

GH

igh

Volta

ge:

Disc

onne

ct a

ll po

wer

bef

ore

serv

icin

g or

inst

allin

g th

is un

it. M

ultip

le p

ower

so

urce

s may

be

pres

ent.

Failu

re to

do

so m

ay c

ause

pro

pert

y da

mag

e, p

erso

nal i

njur

y, or

dea

th.

Page 15: Downloaded from . Since 1968, RS Andrews …€¦ · • Two-stage gas valve operates on two-stage or single-stage thermostats • Effi cient and quiet variable-speed circulator motor

Product SPecificationS

SS-AMV8 www.amana-hac.com 15

adV8 wiring diagram

AUTO RESETFUSE 3 A

YL

24 VAC

PU

DRAFT PRESSURE SWITCH

9 9 FLASHES = HIGH FIRE PRESSURE SWITCH STUCK OPENCONTINUOUS FLASHES = 115 VOLT AC POWER REVERSED

3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE

4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.

2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.

REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE

1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.

RATING OF AT LEAST 105

0140F00081P REV.0

COLOR CODES:YL YELLOW

GR GREENBK BLACK

OR ORANGEPU PURPLE

C

RD RED

BR BROWNWH WHITE

GY GRAYBL BLUE

PK PINK NOTES:

OVERCURRENTPROT. DEVICE

°C. USE COPPER CONDUCTORS ONLY.

ROLL OUT LIMITS CONTROL

8 FLASHES = CHECK IGNITER OR IMPROPER GROUNDING

5 FLASHES = FLAME SENSED WITH GAS VALVE DE-ENERGIZED

3 FLASHES = LOW FIRE PRESSURE SWITCH STUCK OPEN2 FLASHES = LOW FIRE PRESSURE SWITCH STUCK CLOSED

SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED)STEADY ON = NORMAL OPERATION

4 FLASHES = THERMAL PROTECTIVE DEVICE OPEN

7 FLASHES = LOW FLAME SENSE SIGNAL

1 FLASH =

4

6

8

7

1

2

3

0

IGNITORSURFACE

FLAME

HOTSENSOR

WH

BK

1 2 3

2 STAGEGAS VALVE

BR

PM C HI

BL

OR

YL

RD

BLOWER

24V H

UM

IDIFIE

R

HIGH FIREPRESSURE SWITCH

SWITCH (PRESS.)

SWITCH (TEMP.)LINE VOLTAGE

FIELD WIRING

HIGH VOLTAGE

LOW VOLTAGE

FACTORY WIRING

INTEGRATED CONTROL MODULE

TR (9)

MVC (8)

GND (4)

IGNITER

VALVEGAS

C

MANUAL RESET ROLLOUTLIMIT CONTROL

24V HUM.MICROY

24V TH

ER

MO

STA

T CO

NN

EC

TION

S

C

PU

G

MVL(7)

PS2 (2)

MVH (1)C

PS1 (12)

AUXILIARY LIMITCONTROL

YLO

W2

W1

LIMIT CONTROLPRIMARY

BR

HL1 (6)

TO

HLO (11)

NO

PM

HI

PRESSURESWITCH

LOW FIRE

CNO

PRIMARY LIMITCONTROL

WIRING TO UNITMUST BE PROPERLY

ON SOME MODELSINDUCTOR COIL

PRESSURE SWITCH

LOW FIRE

YL

RD

BK

WH

3

2

1

INDUCED

BR

WH

WH

BK

BR

RD

GR

BL

BR

WH

AUXILIARY

RDBL

VAC115

VAC24

BK

RDOR

YL

HOT

YL

LEDDIAGNOSTIC

EAC

LINE

NE UTRAL

5

4

XFM

R

HU

M

CIR

C

LINE

XFM

R

HU

M

EAC

EAC-NEAC-H ELECTRONIC

INTE

GR

ATE

D C

ON

TRO

L MO

DU

LE

INTE

GR

ATE

D C

ON

TRO

L MO

DU

LE

AIR CLEANER

HUMIDIFIER

HOT SURFACE

115 VAC

R

NONO

CC

24

HUM.VAC.

C

NO

TH (5)

XFMR-H

FP (3)IGNITER

FLAME SENSOR

HI FIRE

BLOWER COMPARTMENT

BURNER COMPARTMENT

BLWR

IND LO

HUM-H

IGN-H

IND HIID

XFMR-N

TRANSFORMER40 VA

HUM-N

IGN-N

IND-N

CIRCULATOR

JUNCTION BOX

INDUCTOR COIL

BLWR

LINE-H

90kBTU, 115 KBTUMODELS ONLY

INDOORAIR

POLARIZED ANDGROUNDED.

BLOWERCIRCULATOR

DOORSWITCH

LINE-N

DISCONNECT

FUS

E TWIN

/D

EH

UM

31 2

BL

10 1211

64 5

97 8

2

3

1

24 V THERMOSTAT CONNECTIONS + +

BK 16 WIRE HARNESS

G

16 PINPLUG

B/C

YLO

O Y

24 VAC. HUM.

R W2

W1

OVERCURRENT PROTECTION DEVICEØ /60 HZ POWER SUPPLY WITH

DISCONNECT POWERBEFORE SERVICING.

TO 115VAC/ 1

BK

WARNING:L

GND

LINE-N

LINE HGND

JUNCTION BOX

N

DOOR SWITCH

DEVICEOVERCURRENT PROTECTIONPOWER SUPPLY WITHTO 115 VAC/ 1/60HZ

LIMIT CONTROL

87 9

54 6

11 1210

21 3

1413 15

12 1011

15 14 13

3

6

9

45

78

12

BK

WH

WH

BR

RD

PU

BK

BK

BK

WH

BK

BK

BR

BR

5. USE COPPER CONDUCTORS ONLY

SEENOTE 5

PANELCONTROL

++ - USE NEC CLASS 2 WIRE

SEENOTE 5

LOW VOLTAGE

Wiri

ng is

sub

ject

to

chan

ge. A

lway

s re

fer

to t

he w

iring

dia

gram

on

the

unit

for t

he m

ost u

p-to

-dat

e w

iring

WA

RNIN

GH

igh

Volta

ge:

Disc

onne

ct a

ll po

wer

bef

ore

serv

icin

g or

inst

allin

g th

is un

it. M

ultip

le p

ower

so

urce

s may

be

pres

ent.

Failu

re to

do

so m

ay c

ause

pro

pert

y da

mag

e, p

erso

nal i

njur

y, or

dea

th.

Page 16: Downloaded from . Since 1968, RS Andrews …€¦ · • Two-stage gas valve operates on two-stage or single-stage thermostats • Effi cient and quiet variable-speed circulator motor

Product SPecificationS

16 www.amana-hac.com SS-AMV8

Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P. All rights reserved. Our continuing commit-ment to quality products may mean a change in specifi cations without notice. © 2009 • Goodman Company, L.P. • Houston, Texas • Printed in the USA.

acceSSorieS

MoDel DesCriptionAMV8

0704BXBAMV8

0905CXBAMV8

1155CXBADV8

0703BXBADV8

0905CXBADV8

1155CXB

LPM-03B LP Conversion Kit (Gas Valve) √ √ √ √ √ √

LPM-05 LP Conversion Kit (Springs & Orifi ce) √ √ √ √ √ √

AFE18-60A Fossil Fuel Kit (must be used in a dual-fuel application with a compatible thermostat) √ √ √ √ √ √

ASAS Electronic Air Cleaners (* = -10, -11, -12 or -18) √ √ √ √ √ √

AMU Media Air Cleaners (* = 1620, 2020, 1625 or 2025) √ √ √ √ √ √

tHermoStatS

MoDel two-stAge tHerMostAt DesCription Color

1213411 Digital, Non-Programmable, 2-stage, 2 Heat/2 Cool White

1213407 Digital, Programmable, 2-stage, 2 Heat/1 Gool White

1213406* Programmable, 3-stage, Manual or Automatic Changeover Beige

* For use in dual-fuel applications with a heat pump in a fossil fuel application. It is not for use with the GMV8 as a sole heating source.

A two-stage thermostat should be used with the AMV8 furnace. Two-stage thermostats control which fi ring rate is used depending on the temperature diff erence between the set point and the room temperature. A properly used two-stage thermostat and furnace will maintain a much tighter control of temperature than a conventional single-stage thermostat and furnace. Two-stage furnaces have “W1” and “W2” terminals. If the thermostat has “Y1” and “Y2” cooling connections and a single-stage cooling system is used, connect “Y” on the furnace control to “Y1” on the thermostat. The table below describes two-stage thermostats that have been confi gured for use with this furnace.