Product SPecificationS
SS-AMV8 www.amana-hac.com 6/09Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas. Supersedes5/08
The Amana® brand AMV8/ADV8 two-stage, variable-speed multi-position, gas furnaces provide exceptional indoor comfort and quiet operation. With their two-stage gas valves and variable-speed circulator blowers, these furnaces provide comfort all season long.
Standard Features• Patented MillionAir™ stainless-steel, dual-
diameter tubular heat exchanger with Lifetime Limited Unit Replacement Warranty* for as long as the original registered home-owner owns their home
• Two-stage gas valve operates on two-stage or single-stage thermostats
• Effi cient and quiet variable-speed circulator motor gently ramps up or down according to heating or cooling demand
• SureStart™ Silicon Nitride igniter designed for long igniter life• Furnace control board with self-diagnostics, color-
coded low-voltage terminals, and provisions for electron-ic air cleaner and 120-volt or 24-volt humidifi ers
• Low constant fan allows homeowner to activate very low speed to effi ciently circulate air throughout the home. This setting costs as little as a 100-watt light bulb to operate.
• Quiet, two-speed induced draft blower• All models comply with California NOx emissions standards
Cabinet Features• Fully insulated, heavy-gauge steel cabinet with durable
baked-enamel fi nish• Designed for multi-position installation: upfl ow,
horizontal left or right• Removable bottom for side- or bottom-return applications• Convenient left or right connection for gas/electric service• Coil and furnace fi t fl ush for most installations
ContentsNomenclature .................................................................................................... 2Product Specifi cations .................................................................................. 3Dimensions .......................................................................................................... 4Performance Data ........................................................................................... 6Wiring Diagrams .......................................................................................... 14Accessories .........................................................................................................16
* To receive the Lifetime Heat Exchanger Limited Warranty, Lifetime Unit Replacement Limited War-ranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. Full warranty details available at www.amana-hac.com.
amV8/adV8two-Stage, Variable SPeed
gaS furnace
80% afue
Heating inPut: 70,000–115,000 btu/H
Downloaded from www.rsandrews.com. Since 1968, RS Andrews has proudly served Atlanta's Heating, Air Conditioning & Plumbing Needs.
Product SPecificationS
2 www.amana-hac.com SS-AMV8
nomenclature
Brand RevisionsA Amana® Brand A Initial Release
B 1st RevisionAirflow Direction C 2nd Revision
C Downflow/HorizontalD Dedicated DownflowH High Airflow NOxK Dedicated Upflow N Natural GasM Upflow/Horizontal X Low NOx
Description Cabinet WidthV Two-Stage/Variable-speed A 14”H Two-Stage/Multi-speed B 17½”S Single-Stage/Multi-speed C 21”
D 24½”
AFUE95 95% Maximum CFM @ 0.5” ESP9 90%+ 3 1,2008 80% 4 1,600
MBTU/h 5 2,000045: 45,000 115: 115,000070: 70,000 140: 140,000090: 90,000
9 11A
8B
10XM
21A V
33
5,6,748 70
Product SPecificationS
SS-AMV8 www.amana-hac.com 3
SPecificationS
AMV8 0704BXB
AMV8 0905CXB
AMV8 1155CXB
ADV8 0703BXB
ADV8 0905CXB
ADV8 1155CXB
HeAting CApACity
High Fire Input (BTU/h)¹ 70,000 90,000 115,000 70,000 90,000 115,000
High Fire Output (BTU/h)¹ (below)
Natural Gas 57,000 74,000 93,000 57,400 73,600 92,000
LP Gas 49,000 64,000 82,000 49,252 64,246 85,961
Low Fire Input (BTU/h)¹ 52,500 67,500 86,000 52,500 67,500 86,000
Low Fire Output (BTU/h)¹ (below)
Natural Gas 42,000 54,000 69,000 42,000 54,000 69,000
LP Gas 42,000 54,000 69,000 43,096 55,409 70,595
AFUE2 80 80 80 80 80 80
Available AC @ 0.5” ESP 1.5 - 3.0 2.0 - 5.0 2.0 - 5.0 1.5 - 3.0 2.0 - 5.0 2.0 - 5.0
Temperature Rise Range (° F) 20 - 50 25 - 55 25 - 55 20 - 50 20 - 50 25 - 55
CirCulAtor Blower
Size (D x W) 10” x 8” 10” x 10” 10” x 10” 10” x 8” 10” x 10” 10” x 10”
Horsepower @ 1750 RPM ¾ ¾ ¾ ½ ¾ ¾
Speed Variable Variable Variable Variable Variable Variable
Vent Diameter¹ 4” 4” 4” 4” 4” 4”
No. of Burners 3 4 5 3 4 5
Disposable Filter Size (in2) 576 460 460 576 460 460
eleCtriCAl DAtA
Min. Circuit Ampacity³ 11.7 11.7 11.7 10.4 12.8 12.8
Max. Overcurrent Device (amps)4 15 15 15 15 15 15
Ship Weight (lbs) 152 178 194 156 182 202
1 Natural Gas BTU/h. For altitudes above 2,000’, reduce input rating 4% for each 1,000’ above sea level.2 DOE AFUE based upon Isolated Combustion System (ICS)3 Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with Na-
tional Electrical Codes. Extensive wire runs will require larger wire sizes.4 Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit
breakers of the same size as noted.
notes• All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.• Gas Service Connection ½” FPT• Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all
existing local codes.
Product SPecificationS
4 www.amana-hac.com SS-AMV8
amV8 dimenSionS
minimum clearanceS to combuStible materialS
siDes reAr Front¹Vent²
topsw B
1 0 3 6 1 1
Approved for line contact in the horizontal position.¹ 24” clearance for serviceability recommended.² Single Wall Vent (SW) to be used only as a connector. Refer to the venting tables out-
lined in the Installation Manual for additional venting requirements.
MoDel w D H A B
AMV80704BXB 17½” 28” 39” 17½” 16”
AMV80905CXB 21” 28” 39” 21” 19½”
AMV81155CXB 21” 28” 39” 21” 19½”
�
� � � � � � � � � � �
� � � � � � � � � � � �
� � � � �
� � � � � � � � � � � �
� � � � � � � � � � � � � � � � � �
� � � � � � � � �
� � � � � � � �
� � � � � � � � � � � � � �
� � � � � � � � � � � � � � � � �
� � � � � � � � � � � � � � � �
� � � � �
� � � � � � �
� � � � � �
� � � � � �
� � � � �
� � � � � �
� � � � �
� � � � � �
�
�
� � � � � �
� � � � � �
� � � � � �
� � � � � �
�
� � � � � �
� � � � � � �
� � � �
� � � � �
�28”
39”
Product SPecificationS
SS-AMV8 www.amana-hac.com 5
adV8 dimenSionS
minimum clearanceS to combuStible materialS
siDes reAr Front¹Vent²
topsw B
1 0 3 6 1 1
notesApproved for line contact in the horizontal position.¹ 24” clearance for serviceability recommended.² Single Wall Vent (SW) to be used only as a connector. Refer to the venting tables
outlined in the Installation Manual for additional venting requirements.
MoDel A B
ADV80703BXB 14” 12½”
ADV80905CXB 21” 19½”
ADV81155CXB 21” 19½”
COMPONENT IDENTIFICATION
6
ADV8*****XA
CABINET SIZE A B Non-CombustibleFloor base
ADV80703BX** 17-1/2 16 SBT17
ADV80905CX** 21 19-1/2 SBT21
ADV81155CX** 21 19-1/2 SBT21
All dimensions are in inches.
Gas Inlet
28"4 7/16"
8 5/8"
39"
B 19 5/8"
Low Voltage
High Voltage
Alt. Gas Inlet
1 15/16"
11 3/8"
A
Product SPecificationS
6 www.amana-hac.com SS-AMV8
* Motor CFM maximum † Motor CFM minimumnotes
• These charts are for furnaces installed at 0’ - 2,000’. At higher altitudes, a properly de-rated unit will have the same temperature rise at a particular CFM, while the ESP at that CFM will be lower.
• THE INSTALLATION IS TO BE ADJUSTED TO OBTAIN A TEMPERATURE RISE WITHIN THE RANGE LISTED ON THE FURNACE NAMEPLATE.• Propane gas installations will have a high-stage rise approximately 4° lower than shown in the tables.
low-Stage cooling SPeedS — amV8
AMV80704BXB AMV80905CXB AMV81155CXBCoolingspeeD tAp
ADjust tAp
CFM @ .1” to .8” w.C. esp
CoolingspeeD tAp
ADjust tAp
CFM @ .1” to .8” w.C. esp
CoolingspeeD tAp
ADjust tAp
CFM @ .1” to .8” w.C. esp
AMinus (-) 361†
AMinus (-) 563†
AMinus (-) 563†
Normal 390 Normal 563† Normal 563†Plus (+) 429 Plus (+) 572 Plus (+) 572
BMinus (-) 468
BMinus (-) 644
BMinus (-) 644
Normal 520 Normal 715 Normal 715Plus (+) 572 Plus (+) 787 Plus (+) 787
CMinus (-) 644
CMinus (-) 819
CMinus (-) 819
Normal 715 Normal 910 Normal 910Plus (+) 787 Plus (+) 1,001 Plus (+) 1,001
DMinus (-) 819
DMinus (-) 1,053
DMinus (-) 1,053
Normal 910 Normal 1,170 Normal 1,170Plus (+) 1,001 Plus (+) 1,287 Plus (+) 1,287
HigH- or Single-Stage cooling SPeedS — amV8
AMV80704BXB AMV80905CXB AMV81155CXB
CoolingspeeD tAp
ADjust tAp
CFM @ .1” to .8” w.C. esp
CoolingspeeD tAp
ADjust tAp
CFM @ .1” to .8” w.C. esp
CoolingspeeD tAp
ADjust tAp
CFM @ .1” to .8” w.C. esp
AMinus (-) 540
AMinus (-) 720
AMinus (-) 720
Normal 600 Normal 800 Normal 800Plus (+) 660 Plus (+) 880 Plus (+) 880
BMinus (-) 720
BMinus (-) 990
BMinus (-) 990
Normal 800 Normal 1,100 Normal 1,100Plus (+) 880 Plus (+) 1,210 Plus (+) 1,210
CMinus (-) 990
CMinus (-) 1,260
CMinus (-) 1,260
Normal 1,100 Normal 1,400 Normal 1,400Plus (+) 1,210 Plus (+) 1,540 Plus (+) 1,540
DMinus (-) 1,260
DMinus (-) 1,620
DMinus (-) 1,620
Normal 1,400 Normal 1,800 Normal 1,800Plus (+) 1,540 Plus (+) 1,980 Plus (+) 1,980
amV8 Performance data
Product SPecificationS
SS-AMV8 www.amana-hac.com 7
cooling-baSed continuouS fan – amV8
AMV80704BXB AMV80905CXB AMV81155CXB
Cooling speeD tAp
ADjust tAp
CFM @ .1” to .8” w.C. esp
CoolingspeeD tAp
ADjust tAp
CFM @ .1” to .8” w.C. esp
CoolingspeeD tAp
ADjust tAp
CFM @ .1” to .8” w.C. esp
A
Minus (-) 361†
A
Minus (-) 563†
A
Minus (-) 563†
Normal 361† Normal 563† Normal 563†
Plus (+) 370 Plus (+) 563† Plus (+) 563†
B
Minus (-) 403
B
Minus (-) 563†
B
Minus (-) 563†
Normal 448 Normal 616 Normal 616
Plus (+) 493 Plus (+) 678 Plus (+) 678
C
Minus (-) 554
C
Minus (-) 706
C
Minus (-) 706
Normal 616 Normal 784 Normal 784
Plus (+) 678 Plus (+) 862 Plus (+) 862
D
Minus (-) 706
D
Minus (-) 907
D
Minus (-) 907
Normal 784 Normal 1,008 Normal 1,008
Plus (+) 862 Plus (+) 1,109 Plus (+) 1,109
* Motor CFM maximum† Motor CFM minimum
notes:• These charts are for furnaces installed at 0’ - 4,500’. At higher altitudes, a properly de-rated unit will have the same temperature rise at a
particular CFM, while the ESP at that CFM will be lower.• THE INSTALLATION MUST BE ADJUSTED TO OBTAIN A TEMPERATURE RISE WITHIN THE RANGE LISTED ON THE FURNACE NAMEPLATE.• Propane gas installations will have a high-stage rise approximately 4° lower than shown in the tables.
During Auto-Comfort mode, the furnace ramps up to 50% of the demand for half a minute. It then ramps to 82% of the full cooling demand airflow and operates there for approximately 7½ minutes. The motor then steps up to the full demand airflow. This mode spends a half minute at 50% airflow OFF delay.
auto-comfort mode
amV8 Performance data (cont.)
Product SPecificationS
8 www.amana-hac.com SS-AMV8
amV8 Performance data (cont.)Heating SPeedS
AMV80704BXB(rise rAnge: 20° - 50 °F)
AMV80905CXB(rise rAnge: 25° - 55°F)
HeAting speeD tAp
ADjust tAplow stAge
CFM ¹HigH stAge
CFM ¹ rise ˚F HeAting speeD tAp
ADjust tAp
low stAge CFM ¹
HigH stAge CFM ¹ rise ˚F
AMinus (-) 810 1,077 48
AMinus (-) 945 1,257 53
Normal 900 1,197 43 Normal 1,050 1,397 48Plus(+) 990 1,317 39 Plus(+) 1,155 1,536 43
BMinus (-) 900 1,197 43
BMinus (-) 1,035 1,377 48
Normal 1,000 1,330 39 Normal 1,150 1,530 43Plus(+) 1,100 1,463 35 Plus(+) 1,265 1,682 40
CMinus (-) 990 1,317 39
CMinus (-) 1,125 1,496 44
Normal 1,100 1,463 35 Normal 1,250 1,663 40Plus(+) 1,210 1,609 32 Plus(+) 1,375 1,829 36
DMinus (-) 1,080 1,436 36
DMinus (-) 1,215 1,616 41
Normal 1,200 1,596 32 Normal 1,350 1,796 37Plus(+) 1,320 1650* 29 Plus(+) 1,485 1,975 34
¹ @ .1” to .5” w.c. ESP * Motor CFM maximum † Motor CFM minimum
AMV81155CXB(rise rAnge: 25° - 55°F)
HeAting speeD tAp
ADjust tAplow stAge
CFM ¹HigH stAge
CFM ¹ rise ˚F
AMinus (-) 1,170 1,556 55Normal 1,300 1,729 49Plus(+) 1,430 1,902 45
BMinus (-) 1,215 1,616 53Normal 1,350 1,796 47Plus(+) 1,485 1,975 43
CMinus (-) 1,260 1,676 51Normal 1,400 1,862 46Plus(+) 1,540 2000* 41
DMinus (-) 1,373 1,825 47Normal 1,525 2000* 42Plus(+) 1,678 2000* 38
¹ @ .1” to .5” w.c. ESP * Motor CFM maximum† Motor CFM minimum
notes• These charts are for furnaces installed at 0’ - 4,500’. At higher al-
titudes, a properly de-rated unit will have the same temperature rise at a particular CFM, while the ESP at that CFM will be lower.
• The installation must be adjusted to obtain a temperature rise within the range listed on the furnace nameplate.
• Do not operate above .5” w.c. ESP in heating mode.• Propane gas installations will have a high-stage rise approxi-
mately 4° lower than shown in the tables.
Product SPecificationS
SS-AMV8 www.amana-hac.com 9
amV8 temPerature riSe cHartBLOWER PERFORMANCE SPECIFICATIONS
15
3040
5060
7080
9011
012
010
013
014
015
0
100
90 80 70 60 50 40 30 20 10
OU
TP
UT
BTU
/HR
x 1
000
BTU
OU
TPU
T v
s T
EM
PE
RA
TUR
E R
ISE
CH
AR
TTEMPERATURE RISE
600
CFM
700
900 10
00 1100 12
00
1400
1600 18
00 2000 22
00 2400
CFM
FOR
MU
LAS
BT
U O
UTP
UT
= C
FM x
1.0
8 x
RIS
E
RIS
E =
B
TU
OU
TPU
T
1.08
÷ C
FM
800
Product SPecificationS
10 www.amana-hac.com SS-AMV8
adV8 Performance data
HigH- or Single-Stage cooling SPeedS
ADV80703BXB ADV80905CXB ADV81155CXB
CoolingspeeD tAp
ADjust tAp
CFM¹ CoolingspeeD tAp
ADjust tAp
CFM¹ CoolingspeeD tAp
ADjust tAp
CFM¹
AMinus (-) 540
AMinus (-) 720
AMinus (-) 765
Normal 600 Normal 800 Normal 850Plus (+) 660 Plus (+) 880 Plus (+) 935
BMinus (-) 720
BMinus (-) 990
BMinus (-) 1,035
Normal 800 Normal 1,100 Normal 1,150Plus (+) 880 Plus (+) 1,210 Plus (+) 1,265
CMinus (-) 900
CMinus (-) 1,260
CMinus (-) 1,305
Normal 1,000 Normal 1,400 Normal 1,450Plus (+) 1,100 Plus (+) 1,540 Plus (+) 1,595
DMinus (-) 1,080
DMinus (-) 1,620
DMinus (-) 1,665
Normal 1,200 Normal 1,800 Normal 1,850Plus (+) 1,320 Plus (+) 1,980 Plus (+) 2000*
low-Stage cooling SPeedS
ADV80703BXB ADV80905CXB ADV81155CXB
CoolingspeeD tAp
ADjust tAp
CFM¹ CoolingspeeD tAp
ADjust tAp
CFM¹ CoolingspeeD tAp
ADjust tAp
CFM¹
AMinus (-) 351†
AMinus (-) 468
AMinus (-) 563†
Normal 390 Normal 520 Normal 563†Plus (+) 429 Plus (+) 572 Plus (+) 619
BMinus (-) 468
BMinus (-) 644
BMinus (-) 673
Normal 520 Normal 715 Normal 748Plus (+) 572 Plus (+) 787 Plus (+) 822
CMinus (-) 585
CMinus (-) 819
CMinus (-) 848
Normal 650 Normal 910 Normal 943Plus (+) 715 Plus (+) 1,001 Plus (+) 1,037
DMinus (-) 702
DMinus (-) 1,053
DMinus (-) 1,082
Normal 780 Normal 1,170 Normal 1,203Plus (+) 858 Plus (+) 1,287 Plus (+) 1,323
¹ @ .1” to .8” W.C. ESP* Motor CFM maximum† Motor CFM minimum
notes• These charts are for furnaces installed at 0’ - 4,500’. At higher altitudes, a properly de-rated unit will have the same temperature rise at a
particular CFM, while the ESP at that CFM will be lower.• THE INSTALLATION MUST BE ADJUSTED TO OBTAIN A TEMPERATURE RISE WITHIN THE RANGE LISTED ON THE FURNACE NAMEPLATE.• Propane gas installations will have a high-stage rise approximately 4° lower than shown in the tables.
Product SPecificationS
SS-AMV8 www.amana-hac.com 11
cooling-baSed continuouS fan
ADV80703BXB ADV80905CXB ADV81155CXB
Cooling speeD tAp
ADjust tAp
CFM¹ CoolingspeeD tAp
ADjust tAp
CFM¹ CoolingspeeD tAp
ADjust tAp
CFM¹
A
Minus (-) 302
A
Minus (-) 403
A
Minus (-) 563†
Normal 336 Normal 448 Normal 563†
Plus (+) 370 Plus (+) 493 Plus (+) 563†
B
Minus (-) 403
B
Minus (-) 554
B
Minus (-) 580
Normal 448 Normal 616 Normal 644
Plus (+) 493 Plus (+) 678 Plus (+) 708
C
Minus (-) 504
C
Minus (-) 706
C
Minus (-) 731
Normal 560 Normal 784 Normal 812
Plus (+) 616 Plus (+) 862 Plus (+) 893
D
Minus (-) 605
D
Minus (-) 907
D
Minus (-) 932
Normal 672 Normal 1,008 Normal 1,036
Plus (+) 739 Plus (+) 1,109 Plus (+) 1,140
¹ @ .1” to .8” W.C. ESP * Motor CFM maximum† Motor CFM minimum
notes:• These charts are for furnaces installed at 0’ - 4,500. At higher altitudes, a properly de-rated unit will have the same temperature rise
at a particular CFM, while the ESP at that CFM will be lower.• THE INSTALLATION MUST BE ADJUSTED TO OBTAIN A TEMPERATURE RISE WITHIN THE RANGE LISTED ON THE FURNACE NAMEPLATE.• Propane gas installations will have a high-stage rise approximately 4° lower than shown in the tables.
adV8 Performance data (cont.)
Product SPecificationS
12 www.amana-hac.com SS-AMV8
Heating SPeedS
ADV80703BXB(rise rAnge: 20° - 50°F)
ADV80905CXB(rise rAnge: 20° - 50°F)
HeAting speeD tAp
ADjust tAplow-stAge
CFM¹HigH-stAge
CFM¹rise ˚F
HeAting speeD tAp
ADjust tAplow-stAge
CFM¹HigH-stAge
CFM¹rise ˚F
AMinus (-) 720 958 ---
AMinus (-) 945 1,257 ---
Normal 800 1,064 49 Normal 1,050 1,397 48Plus(+) 880 1,170 44 Plus(+) 1,155 1,536 43
BMinus (-) 810 1,077 48
BMinus (-) 1,035 1,377 48
Normal 900 1,197 43 Normal 1,150 1,530 43Plus(+) 990 1,317 39 Plus(+) 1,265 1,682 40
CMinus (-) 900 1,197 43
CMinus (-) 1,125 1,496 44
Normal 1,000 1,330 39 Normal 1,250 1,663 40Plus(+) 1,100 1,463 35 Plus(+) 1,375 1,829 36
DMinus (-) 990 1,317 39
DMinus (-) 1,215 1,616 41
Normal 1,100 1,463 35 Normal 1,350 1,796 37Plus(+) 1,210 1,609 32 Plus(+) 1,485 1,975 34
¹ @ .1” to .5” w.c. ESP * Motor CFM maximum † Motor CFM minimum
ADV81155CXB(rise rAnge: 25° - 55°F)
HeAting speeD tAp
ADjust tAplow-stAge
CFM¹HigH-stAge
CFM¹rise ˚F
AMinus (-) 1,215 1,616 52Normal 1,350 1,796 47Plus(+) 1,485 1,975 43
BMinus (-) 1,260 1,676 51Normal 1,400 1,862 46Plus(+) 1,540 2000* 41
CMinus (-) 1,305 1,736 49Normal 1,450 1,929 44Plus(+) 1,595 2000* 40
DMinus (-) 1,418 1,885 45Normal 1,575 2000* 40Plus(+) 1,733 2000* 37
¹ @ .1” to .5” w.c. ESP * Motor CFM maximum † Motor CFM minimum
notes• These charts are for furnaces installed at 0’- 4,500’. At higher
altitudes, a properly de-rated unit will have the same tempera-ture rise at a particular CFM, while the ESP at that CFM will be lower.
• The installation must be adjusted to obtain a temperature rise within the range listed on the furnace nameplate.
• Do not operate above .5” w.c. ESP in heating mode.• Propane gas installations will have a high-stage rise approxi-
mately 4° lower than shown in the tables.
adV8 Performance data (cont.)
Product SPecificationS
SS-AMV8 www.amana-hac.com 13
adV8 temPerature riSe cHartBLOWER PERFORMANCE SPECIFICATIONS
15
3040
5060
7080
9011
012
010
013
014
015
0
100
90 80 70 60 50 40 30 20 10
OU
TP
UT
BT
U/H
R x
100
0
BT
U O
UT
PU
T v
s T
EM
PE
RA
TU
RE
RIS
E C
HA
RT
TEMPERATURE RISE
600
CF
M 700
900 10
00 1100 12
00
1400
1600 18
00 2000 22
00 2400
CF
M
FO
RM
ULA
SB
TU
OU
TP
UT
= C
FM
x 1
.08
x R
ISE
RIS
E =
B
TU
OU
TP
UT
1.08
÷ C
FM
800
Product SPecificationS
14 www.amana-hac.com SS-AMV8
amV8 wiring diagram
Wiri
ng is
sub
ject
to
chan
ge. A
lway
s re
fer
to t
he w
iring
dia
gram
on
the
unit
for t
he m
ost u
p-to
-dat
e w
iring
WA
RNIN
GH
igh
Volta
ge:
Disc
onne
ct a
ll po
wer
bef
ore
serv
icin
g or
inst
allin
g th
is un
it. M
ultip
le p
ower
so
urce
s may
be
pres
ent.
Failu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, or
dea
th.
Product SPecificationS
SS-AMV8 www.amana-hac.com 15
adV8 wiring diagram
AUTO RESETFUSE 3 A
YL
24 VAC
PU
DRAFT PRESSURE SWITCH
9 9 FLASHES = HIGH FIRE PRESSURE SWITCH STUCK OPENCONTINUOUS FLASHES = 115 VOLT AC POWER REVERSED
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE
4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
RATING OF AT LEAST 105
0140F00081P REV.0
COLOR CODES:YL YELLOW
GR GREENBK BLACK
OR ORANGEPU PURPLE
C
RD RED
BR BROWNWH WHITE
GY GRAYBL BLUE
PK PINK NOTES:
OVERCURRENTPROT. DEVICE
°C. USE COPPER CONDUCTORS ONLY.
ROLL OUT LIMITS CONTROL
8 FLASHES = CHECK IGNITER OR IMPROPER GROUNDING
5 FLASHES = FLAME SENSED WITH GAS VALVE DE-ENERGIZED
3 FLASHES = LOW FIRE PRESSURE SWITCH STUCK OPEN2 FLASHES = LOW FIRE PRESSURE SWITCH STUCK CLOSED
SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED)STEADY ON = NORMAL OPERATION
4 FLASHES = THERMAL PROTECTIVE DEVICE OPEN
7 FLASHES = LOW FLAME SENSE SIGNAL
1 FLASH =
4
6
8
7
1
2
3
0
IGNITORSURFACE
FLAME
HOTSENSOR
WH
BK
1 2 3
2 STAGEGAS VALVE
BR
PM C HI
BL
OR
YL
RD
BLOWER
24V H
UM
IDIFIE
R
HIGH FIREPRESSURE SWITCH
SWITCH (PRESS.)
SWITCH (TEMP.)LINE VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
FACTORY WIRING
INTEGRATED CONTROL MODULE
TR (9)
MVC (8)
GND (4)
IGNITER
VALVEGAS
C
MANUAL RESET ROLLOUTLIMIT CONTROL
24V HUM.MICROY
24V TH
ER
MO
STA
T CO
NN
EC
TION
S
C
PU
G
MVL(7)
PS2 (2)
MVH (1)C
PS1 (12)
AUXILIARY LIMITCONTROL
YLO
W2
W1
LIMIT CONTROLPRIMARY
BR
HL1 (6)
TO
HLO (11)
NO
PM
HI
PRESSURESWITCH
LOW FIRE
CNO
PRIMARY LIMITCONTROL
WIRING TO UNITMUST BE PROPERLY
ON SOME MODELSINDUCTOR COIL
PRESSURE SWITCH
LOW FIRE
YL
RD
BK
WH
3
2
1
INDUCED
BR
WH
WH
BK
BR
RD
GR
BL
BR
WH
AUXILIARY
RDBL
VAC115
VAC24
BK
RDOR
YL
HOT
YL
LEDDIAGNOSTIC
EAC
LINE
NE UTRAL
5
4
XFM
R
HU
M
CIR
C
LINE
XFM
R
HU
M
EAC
EAC-NEAC-H ELECTRONIC
INTE
GR
ATE
D C
ON
TRO
L MO
DU
LE
INTE
GR
ATE
D C
ON
TRO
L MO
DU
LE
AIR CLEANER
HUMIDIFIER
HOT SURFACE
115 VAC
R
NONO
CC
24
HUM.VAC.
C
NO
TH (5)
XFMR-H
FP (3)IGNITER
FLAME SENSOR
HI FIRE
BLOWER COMPARTMENT
BURNER COMPARTMENT
BLWR
IND LO
HUM-H
IGN-H
IND HIID
XFMR-N
TRANSFORMER40 VA
HUM-N
IGN-N
IND-N
CIRCULATOR
JUNCTION BOX
INDUCTOR COIL
BLWR
LINE-H
90kBTU, 115 KBTUMODELS ONLY
INDOORAIR
POLARIZED ANDGROUNDED.
BLOWERCIRCULATOR
DOORSWITCH
LINE-N
DISCONNECT
FUS
E TWIN
/D
EH
UM
31 2
BL
10 1211
64 5
97 8
2
3
1
24 V THERMOSTAT CONNECTIONS + +
BK 16 WIRE HARNESS
G
16 PINPLUG
B/C
YLO
O Y
24 VAC. HUM.
R W2
W1
OVERCURRENT PROTECTION DEVICEØ /60 HZ POWER SUPPLY WITH
DISCONNECT POWERBEFORE SERVICING.
TO 115VAC/ 1
BK
WARNING:L
GND
LINE-N
LINE HGND
JUNCTION BOX
N
DOOR SWITCH
DEVICEOVERCURRENT PROTECTIONPOWER SUPPLY WITHTO 115 VAC/ 1/60HZ
LIMIT CONTROL
87 9
54 6
11 1210
21 3
1413 15
12 1011
15 14 13
3
6
9
45
78
12
BK
WH
WH
BR
RD
PU
BK
BK
BK
WH
BK
BK
BR
BR
5. USE COPPER CONDUCTORS ONLY
SEENOTE 5
PANELCONTROL
++ - USE NEC CLASS 2 WIRE
SEENOTE 5
LOW VOLTAGE
Wiri
ng is
sub
ject
to
chan
ge. A
lway
s re
fer
to t
he w
iring
dia
gram
on
the
unit
for t
he m
ost u
p-to
-dat
e w
iring
WA
RNIN
GH
igh
Volta
ge:
Disc
onne
ct a
ll po
wer
bef
ore
serv
icin
g or
inst
allin
g th
is un
it. M
ultip
le p
ower
so
urce
s may
be
pres
ent.
Failu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, or
dea
th.
Product SPecificationS
16 www.amana-hac.com SS-AMV8
Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P. All rights reserved. Our continuing commit-ment to quality products may mean a change in specifi cations without notice. © 2009 • Goodman Company, L.P. • Houston, Texas • Printed in the USA.
acceSSorieS
MoDel DesCriptionAMV8
0704BXBAMV8
0905CXBAMV8
1155CXBADV8
0703BXBADV8
0905CXBADV8
1155CXB
LPM-03B LP Conversion Kit (Gas Valve) √ √ √ √ √ √
LPM-05 LP Conversion Kit (Springs & Orifi ce) √ √ √ √ √ √
AFE18-60A Fossil Fuel Kit (must be used in a dual-fuel application with a compatible thermostat) √ √ √ √ √ √
ASAS Electronic Air Cleaners (* = -10, -11, -12 or -18) √ √ √ √ √ √
AMU Media Air Cleaners (* = 1620, 2020, 1625 or 2025) √ √ √ √ √ √
tHermoStatS
MoDel two-stAge tHerMostAt DesCription Color
1213411 Digital, Non-Programmable, 2-stage, 2 Heat/2 Cool White
1213407 Digital, Programmable, 2-stage, 2 Heat/1 Gool White
1213406* Programmable, 3-stage, Manual or Automatic Changeover Beige
* For use in dual-fuel applications with a heat pump in a fossil fuel application. It is not for use with the GMV8 as a sole heating source.
A two-stage thermostat should be used with the AMV8 furnace. Two-stage thermostats control which fi ring rate is used depending on the temperature diff erence between the set point and the room temperature. A properly used two-stage thermostat and furnace will maintain a much tighter control of temperature than a conventional single-stage thermostat and furnace. Two-stage furnaces have “W1” and “W2” terminals. If the thermostat has “Y1” and “Y2” cooling connections and a single-stage cooling system is used, connect “Y” on the furnace control to “Y1” on the thermostat. The table below describes two-stage thermostats that have been confi gured for use with this furnace.