ARCHITECTURAL ‘CAP-LESS’ SOLUTIONS FOR PARAPET WALLS & BALCONY HEADS

Transcript of Download Construction Manual - Masterwall Australia · PDF fileNo part of this document is to...

Page 1: Download Construction Manual - Masterwall Australia · PDF fileNo part of this document is to be copied or reproduced without the express written permission of MasterWall Australia

SYSTEM INSTALLATION & CONSTRUCTION DETAIL MANUAL

SKYLINE TECHNICAL DOCUMENT 13.06.2013

ARCHITECTURAL‘CAP-LESS’ SOLUTIONSFOR PARAPET WALLS & BALCONY HEADS

Page 2: Download Construction Manual - Masterwall Australia · PDF fileNo part of this document is to be copied or reproduced without the express written permission of MasterWall Australia

2 COPYRIGHT 2017. No part of this document is to be copied or reproduced without the express written permission of MasterWall Australia Pty Ltd. 24.02.20172 COPYRIGHT 2017. No part of this document is to be copied or reproduced without the express written permission of MasterWall Australia Pty Ltd.

SKYL

INE

OVE

R M

AST

ERW

ALL

SYS

TEM

.

SKYL

INE

MEM

BRA

NE:

Adva

nced

wat

erpr

oof m

embr

ane

to b

eap

plie

d as

per

Sky

line

Syst

em S

peci

�cat

ion.

STU

D F

RAM

E

FIXI

NG

S:75

mm

�xi

ng a

nd 4

0mm

but

ton

set

REN

DER

PRO

CESS

MA

STER

WA

LL B

REAT

HER

WRA

P:A

supe

rior t

rans

luce

nt b

reat

her f

ram

e w

rap

whi

ch

prov

ides

hig

h pe

rform

ance

vap

or p

erm

eabi

lity.

FIB

REG

LASS

REI

NFO

RCIN

G M

ESH

:Em

bedd

ed in

�rs

t lay

er o

f pol

ymer

rend

er.

MES

HED

& P

RIM

ED M

AST

ERW

ALL

PA

NEL

S:

Thic

knes

ses:

50/

75/1

00/1

25m

m R

1.8

/2.5

/3.2

/3.9

.**

Incl

udes

R 0

.5 a

llow

ance

for 9

0mm

fram

e, 1

0mm

pla

ster

boar

d.

Suita

ble

for B

AL 2

9 - s

ee M

aste

rWal

l Spe

ci�c

atio

ns.

ALL

OY

EXTE

RNA

L CO

RNER

S:

With

inte

grat

ed m

esh

retu

rns.

POLY

STYR

ENE

H-G

RAD

E W

EDG

E:(R

efer

to M

aste

rWal

l K-S

erie

s Sy

stem

In

stal

latio

n an

d Co

nstru

ctio

n De

tail

man

ual f

or B

AL40

det

ail).

NOT

E:

For B

ox G

utte

r det

ail,

retu

rn d

own

with

F/C

she

et (R

efer

to C

onst

ruct

ion

Deta

il in

Sky

line

Broc

hure

)

Page 3: Download Construction Manual - Masterwall Australia · PDF fileNo part of this document is to be copied or reproduced without the express written permission of MasterWall Australia

3COPYRIGHT 2017. No part of this document is to be copied or reproduced without the express written permission of MasterWall Australia Pty Ltd.

SYSTEM SPECIFICATION

SKYLINE EXPLODED VIEW DIAGRAM Frame Construction 2

INTRODUCTION Description 4Polystyrene Wedge 4 Fibre Cement (F/C) 4Brick / Masonry 4Detail Tape 4Layout 4Cutting 4Health and Safety 4Method 4Joint Tape 5Adhesive Parging 5Penetrations 5Warranty - 7 years 5Render 5

CONSTRUCTION DETAILSRendered parapet wall 6MasterWall panel. Suitable for up to BAL 29. Rendered parapet wall (Close up detail) 7MasterWall panel. Suitable for up to BAL 29. Rendered parapet wall 8Kooltherm panel. Suitable for up to BAL 29. Rendered parapet wall (Close up detail) 9Kooltherm panel. Suitable for up to BAL 29. BAL 40 rendered parapet wallKooltherm panel. Suitable for up to BAL 40. 10BAL 40 rendered parapet wall (Close up detail)Kooltherm panel. Suitable for up to BAL 40. 11 Brick veneer 12Double brick parapet without slope 13Double brick parapet with slope 13Masonry wall control joint 14Elevation view (front)Masonry wall control joint 15Plan view (top) Masonry wall control joint 15Elevation view (rear) Concealed flashing detail 16Waterproof ledge or similarTape placement detail 17Checklist and notes 18

Page 4: Download Construction Manual - Masterwall Australia · PDF fileNo part of this document is to be copied or reproduced without the express written permission of MasterWall Australia

4 COPYRIGHT 2017. No part of this document is to be copied or reproduced without the express written permission of MasterWall Australia Pty Ltd. 24.02.2017

INTRODUCTION

Description

The Skyline membrane may be installed over substrates that have a smooth surface for a strong bond, such as polystyrene, fibre cement, plywood, MasterWall panel, smooth render, concrete or smooth masonry. The Skyline membrane will adhere to rough surfaces when parged with Skyline compatible adhesive (consult MasterWall Australia). Adhesion test may be required.

Polystyrene Wedge

H Grade polystyrene wedges are recommended to parapet designs and should have a fall of 7° minimum back into the box gutter to avoid water run off the front edge of the building. Wedges should be screwed to parapet frame at 300mm centres using MasterWall fixings with 40mm red washers. Mitre all external/internal corners and tightly butt all joints together, no adhesive is required to wedge joints. Apply MasterWall Joint Foam between wedge/ MasterWall panel junction to seal joint on vertical face.

Fibre Cement (F/C)

When using F/C sheet as a surface for Skyline to bond to, a minimum of 4.5mm thick material should be used, such as with the drop down component into a box gutter on a parapet. Use only 6mm F/C sheet or greater on all horizontal surfaces such as balcony balustrades or cavity brick parapet when used as a cap. Use ‘cement tile adhesive’ to bond F/C to brick or masonry substrates.

Brick / Masonry

Bonding Skyline membrane to rough brick will require parging with a Skyline compatible adhesive or alternatively the surface can be coated with a smooth render finish which Skyline membrane will bond to as with brick veneer. A test patch should be performed to ensure good adhesion will result. Note: any smooth render should be dry prior to applying Skyline. Cavity brick will require a 6mm minimum F/C cap bonded with tile adhesive, and brick veneer a polystyrene cap to the rear (See details on page 13).

Detail Tape

Skyline compatible detail tape is to be applied to all ‘3 surface junctions’ to ensure complete water-tightness is achieved at the point of junction. (See detail on page 17 Detail tape should be 50x50mm square and pressed firmly onto all adjacent surface planes at the junction point. Avoid touching raw detail tape with hands, by using plastic film backing once removed from tape. (See Skyline installation video for correct technique)

Layout

Skyline membrane is to terminate minimum of 35mm onto all vertical surfaces to form a ‘cap’ for water runoff. All joins in the membrane shall overlap 75mm minimum. Vertical returns onto MasterWall cladding to be rendered shall be 75mm. Vertical returns behind alternative cladding shall be 100mm.

Cutting

Use sharp clean knife only to cut Skyline membrane.

Health and Safety

Skyline membrane poses no issues when coming in contact with skin; however avoid contact with eyes. Dispose all waste off cut material according local refuse regulations.

Method

Ensure all substrates are clean of dirt & dust and free of organic matter and solvents. Peel paper from back of Skyline membrane, smoothing out over applied area while working from one direction to ensure no air pockets exist. Apply strong pressure either by hand or roller to activate the adhesive bond of the butyl to the substrate.

Page 5: Download Construction Manual - Masterwall Australia · PDF fileNo part of this document is to be copied or reproduced without the express written permission of MasterWall Australia

5COPYRIGHT 2017. No part of this document is to be copied or reproduced without the express written permission of MasterWall Australia Pty Ltd.

Joint Tape

Lap all membrane joins by 75mm minimum. Apply Skyline compatible adhesive to area to be bonded only, by laying two beads of adhesive, and smearing over entire bonded area with a scraper to a thin film of around 1mm. (See Skyline installation video for correct technique) None of the polyester fibre should be visible once adhesive is spread. Press top layer of Skyline onto the adhesive and apply hand pressure to firmly bond. (Note: avoid spreading adhesive on exposed face of Skyline that is to be rendered)

Adhesive Parging

To parge Skyline to substrate, apply 8mm beads of adhesive to substrate 40mm apart, and smear over entire bonded area with a scraper to a thin film of around 1mm. None of the substrate should be visible. Press Skyline onto the adhesive and apply hand pressure to firmly bond. (Note: avoid spreading adhesive on exposed face of Skyline that is to be rendered)

Penetrations

Ensure that no nails/screws or other fixings penetrate through the final Skyline membrane as it is a total waterproofing solution. This would void all warranties.

Warranty - 7 Years

MasterWall Australia Pty Ltd warrants that its products are free from defects in materials and workmanship for a period of 7 years from the date of purchase. For a full description of the Warranty refer to the MasterWall Australia website (http://www.masterwall.com.au).

Render

A minimum thickness of 5mm polymer modified render should be applied in two coats over entire Skyline system. A single layer of alkali resistant mesh (145–160 g/m2) must be embedded into the first coat of render.

Render trims should be pre-meshed alloy and should be either glued or embedded into first coat of render. Do not fix with nails or any fixing methods that entail the piercing of the Skyline membrane.

A texture finish to the coating manufacturer’s specification may be applied. It is highly recommended that in a parapet design the render system be over coated with an acrylic membrane for added protection and long term durability of the system.

Page 6: Download Construction Manual - Masterwall Australia · PDF fileNo part of this document is to be copied or reproduced without the express written permission of MasterWall Australia

6 COPYRIGHT 2017. No part of this document is to be copied or reproduced without the express written permission of MasterWall Australia Pty Ltd. 24.02.2017

These details are indicative for the purpose of illustrating the typical installation of Skyline system. The system is to be installed strictly in accordance with the specifications detailed in the forward section of this manual. Substrate construction to be in accordance with the Building Regulations & Statutory Requirements.

Box

gu

tter

4.5

mm

F/C

sh

eet

wit

h

50m

m w

idth

ret

urn

ed in

to

box

gu

tter

Min

fall

Poly

styr

ene

H-G

rad

e w

edg

e

Raf

ter

Fib

reg

lass

rei

nfo

rcin

g m

esh

to

cov

er g

ap

bet

wee

n a

lloy

ang

le m

esh

ret

urn

s

Mas

terW

all®

pan

el

Sky

line

mem

bra

ne

(to

be

app

lied

as

per

S

kylin

e S

yste

m S

pec

i�ca

tio

n)

Min

imu

m 5

mm

ap

pro

ved

acr

ylic

re

nd

er s

yste

m

Mas

terW

all B

reat

her

Fra

me

Wra

p

Not

e: D

o no

t pea

rce

Skyl

ine

mem

bran

e w

ith m

echa

nica

l fas

tner

s th

roug

h th

e ho

rizo

ntal

pla

ne

All

exte

rnal

co

rner

s re

info

rced

wit

h a

lloy

ren

der

b

ead

wit

h in

teg

ral �

ber

gla

ss

mes

h r

ein

forc

ing

str

ip

SKYLINE SYSTEM / MASTERWALL® PANEL:

RENDERED PARAPET WALL

These details are indicative for the purpose of illustrating the typical installation of Skyline system. The system is to be installed strictly in accordance with the speci�cations detailed in the forward section of this manual. Substrate construction to be in accordance with the Building Regulations & Statutory Requirements.

SUITABLE FOR BAL 12.5, 19 & 29. FOR BAL 40 SEE PAGES 10 & 11.

Ad

equ

ate

bea

d o

f ex

pan

dab

le f

oam

co

nst

ruct

ion

ure

than

e at

mid

po

int

of

pan

el t

hic

knes

s

Mas

terW

all a

pp

rove

d 7

5mm

xin

g &

40m

m b

utt

on

set

Mas

terW

all a

pp

rove

d �

xin

g

& 4

0mm

bu

tto

n s

et

Page 7: Download Construction Manual - Masterwall Australia · PDF fileNo part of this document is to be copied or reproduced without the express written permission of MasterWall Australia

7COPYRIGHT 2017. No part of this document is to be copied or reproduced without the express written permission of MasterWall Australia Pty Ltd.

These details are indicative for the purpose of illustrating the typical installation of Skyline system. The system is to be installed strictly in accordance with the specifications detailed in the forward section of this manual. Substrate construction to be in accordance with the Building Regulations & Statutory Requirements.

SKYLINE SYSTEM / MASTERWALL® PANEL:

RENDERED PARAPET WALL (CLOSE UP DETAIL)

These details are indicative for the purpose of illustrating the typical installation of Skyline system. The system is to be installed strictly in accordance with the speci�cations detailed in the forward section of this manual. Substrate construction to be in accordance with the Building Regulations & Statutory Requirements.

Not

e: D

o no

t pea

rce

Skyl

ine

mem

bran

e w

ith m

echa

nica

l fas

tner

s th

roug

h th

e ho

rizo

ntal

pla

nel

Mas

terW

all B

reat

her

Fra

me

Wra

p

Box

gu

tter

4.5m

m F

/C s

hee

t M

in. 5

0mm

in w

idth

Sky

line

Mem

bra

ne

(to

be

app

lied

as

per

S

kylin

e S

yste

m S

pec

i�ca

tio

n)

Min

imu

m 5

mm

ap

pro

ved

mes

h

rein

forc

ed p

oly

mer

ren

der

sys

tem

Poly

styr

ene

H G

rad

e w

edg

e

Fib

reg

lass

rei

nfo

rcin

g m

esh

to

cov

er g

ap

bet

wee

n a

lloy

ang

le m

esh

ret

urn

s

All

exte

rnal

co

rner

s re

info

rced

wit

h a

lloy

ren

der

b

ead

wit

h in

teg

ral �

ber

gla

ss

mes

h r

ein

forc

ing

str

ip

SUITABLE FOR BAL 12.5, 19 & 29. FOR BAL 40 SEE PAGES 10 & 11.

Mas

terW

all a

pp

rove

d �

xin

g

& 4

0mm

bu

tto

n s

et

Mas

terW

all a

pp

rove

d 7

5mm

�xi

ng

&

40m

m b

utt

on

set

Ad

equ

ate

bea

d o

f ex

pan

dab

le f

oam

co

nst

ruct

ion

ure

than

e at

mid

po

int

of

pan

el t

hic

knes

s

Page 8: Download Construction Manual - Masterwall Australia · PDF fileNo part of this document is to be copied or reproduced without the express written permission of MasterWall Australia

8 COPYRIGHT 2017. No part of this document is to be copied or reproduced without the express written permission of MasterWall Australia Pty Ltd. 24.02.2017

These details are indicative for the purpose of illustrating the typical installation of Skyline system. The system is to be installed strictly in accordance with the specifications detailed in the forward section of this manual. Substrate construction to be in accordance with the Building Regulations & Statutory Requirements.

Box

gu

tter

F/C

sh

eet

4.5m

m w

ith

50

mm

wid

th r

etu

rned

in

to b

ox g

utt

er

Min

fall

Rafte

r

Poly

styr

ene

H-G

rad

e w

edg

e

Koolt

her

m® p

anel

Not

e: D

o no

t pea

rce

Skyl

ine

mem

bran

e w

ith m

echa

nica

l fas

tner

s th

roug

h th

e ho

rizo

ntal

pla

nel

These details are indicative for the purpose of illustrating the typical installation of Skyline system. The system is to be installed strictly in accordance with the speci�cations detailed in the forward section of this manual. Substrate construction to be in accordance with the Building Regulations & Statutory Requirements.

Sky

line

mem

bra

ne

(to

be

app

lied

as

per

S

kylin

e S

yste

m S

pec

i�ca

tio

n)

Fib

reg

lass

rei

nfo

rcin

g m

esh

ove

r en

tire

Koolt

her

m® p

anel

sys

tem

Min

imu

m 5

mm

ap

pro

ved

mes

h r

ein

forc

ed

po

lym

er r

end

er s

yste

m

Mas

terW

all B

reat

her

Fra

me

Wra

p

All

exte

rnal

co

rner

s re

info

rced

wit

h a

lloy

ren

der

b

ead

wit

h in

teg

ral �

ber

gla

ss

mes

h r

ein

forc

ing

str

ip

SKYLINE SYSTEM / Kooltherm® PANEL:

RENDERED PARAPET WALLSUITABLE FOR BAL 12.5, 19 & 29. FOR BAL 40 SEE PAGES 10 & 11.

Fib

reg

lass

rei

nfo

rcin

g m

esh

to

cov

er g

ap

bet

wee

n a

lloy

ang

le m

esh

ret

urn

s

Ad

equ

ate

bea

d o

f ex

pan

dab

le f

oam

co

nst

ruct

ion

ure

than

e at

mid

po

int

of

pan

el t

hic

knes

s

Mas

terW

all a

pp

rove

d 7

5mm

xin

g &

50m

m b

utt

on

set

Mas

terW

all a

pp

rove

d �

xin

g

& 5

0mm

bu

tto

n s

et

Page 9: Download Construction Manual - Masterwall Australia · PDF fileNo part of this document is to be copied or reproduced without the express written permission of MasterWall Australia

9COPYRIGHT 2017. No part of this document is to be copied or reproduced without the express written permission of MasterWall Australia Pty Ltd.

These details are indicative for the purpose of illustrating the typical installation of Skyline system. The system is to be installed strictly in accordance with the specifications detailed in the forward section of this manual. Substrate construction to be in accordance with the Building Regulations & Statutory Requirements.

Not

e: D

o no

t pea

rce

Skyl

ine

mem

bran

e w

ith m

echa

nica

l fas

tner

s th

roug

h th

e ho

rizo

ntal

pla

nel

Mas

terW

all B

reat

her

Fra

me

Wra

p

Box

gu

tter

Mas

terW

all a

pp

rove

d 7

5mm

�xi

ng

&

50m

m b

utt

on

set

4.5m

m F

/C s

hee

t -

50m

m w

idth

Sky

line

Mem

bra

ne

(to

be

app

lied

as

per

S

kylin

e S

yste

m S

pec

i�ca

tio

n)

Fib

reg

lass

rei

nfo

rcin

g m

esh

Min

imu

m 5

mm

ap

pro

ved

mes

h

rein

forc

ed p

oly

mer

ren

der

sys

tem

All

exte

rnal

co

rner

s re

info

rced

wit

h a

lloy

ren

der

b

ead

wit

h in

teg

ral �

ber

gla

ss

mes

h r

ein

forc

ing

str

ip

These details are indicative for the purpose of illustrating the typical installation of Skyline system. The system is to be installed strictly in accordance with the speci�cations detailed in the forward section of this manual. Substrate construction to be in accordance with the Building Regulations & Statutory Requirements.

SKYLINE SYSTEM / Kooltherm® PANEL:

RENDERED PARAPET WALLSUITABLE FOR BAL 12.5, 19 & 29. FOR BAL 40 SEE PAGES 10 & 11.

Poly

styr

ene

H G

rad

e w

edg

e

Fib

reg

lass

rei

nfo

rcin

g m

esh

to

cov

er g

ap

bet

wee

n a

lloy

ang

le m

esh

ret

urn

s

Mas

terW

all a

pp

rove

d 7

5mm

�xi

ng

&

50m

m b

utt

on

set

Ad

equ

ate

bea

d o

f ex

pan

dab

le f

oam

co

nst

ruct

ion

ure

than

e at

mid

po

int

of

pan

el t

hic

knes

s

Page 10: Download Construction Manual - Masterwall Australia · PDF fileNo part of this document is to be copied or reproduced without the express written permission of MasterWall Australia

10 COPYRIGHT 2017. No part of this document is to be copied or reproduced without the express written permission of MasterWall Australia Pty Ltd. 24.02.2017

These details are indicative for the purpose of illustrating the typical installation of Skyline system. The system is to be installed strictly in accordance with the specifications detailed in the forward section of this manual. Substrate construction to be in accordance with the Building Regulations & Statutory Requirements.

Box

gu

tter

F/C

sh

eet

4.5m

m w

ith

50m

m

wid

th r

etu

rned

into

box

gu

tter

Raf

ter

Min

imu

m 5

mm

ap

pro

ved

mes

h r

ein

forc

ed

po

lym

er m

od

i�ed

ren

der

sys

tem

Koolt

her

m® p

anel

Mas

terW

all B

reat

her

Fra

me

Wra

p

Not

e: D

o no

t pea

rce

Skyl

ine

mem

bran

e w

ith m

echa

nica

l fas

tner

s th

roug

h th

e ho

rizo

ntal

pla

nel

Sky

line

mem

bra

ne

(to

be

app

lied

as

per

S

kylin

e S

yste

m S

pec

i�ca

tio

n)

Mas

terW

all a

pp

rove

d a

dh

esiv

e

F/C

sh

eet

4.5m

m

Min

fall

Poly

styr

ene

H-G

rad

e w

edg

e

These details are indicative for the purpose of illustrating the typical installation of Skyline system. The system is to be installed strictly in accordance with the speci�cations detailed in the forward section of this manual. Substrate construction to be in accordance with the Building Regulations & Statutory Requirements.

All

exte

rnal

co

rner

s re

info

rced

wit

h a

lloy

ren

der

b

ead

wit

h in

teg

ral �

ber

gla

ss

mes

h r

ein

forc

ing

str

ip

SKYLINE SYSTEM / Kooltherm® PANEL:

BAL 40 RENDERED PARAPET WALL

Fib

reg

lass

rei

nfo

rcin

g m

esh

to

cov

er g

ap

bet

wee

n a

lloy

ang

le m

esh

ret

urn

s

Mas

terW

all a

pp

rove

d 7

5mm

xin

g &

50m

m b

utt

on

set

Mas

terW

all a

pp

rove

d �

xin

g

& 5

0mm

bu

tto

n s

et

Page 11: Download Construction Manual - Masterwall Australia · PDF fileNo part of this document is to be copied or reproduced without the express written permission of MasterWall Australia

11COPYRIGHT 2017. No part of this document is to be copied or reproduced without the express written permission of MasterWall Australia Pty Ltd.

These details are indicative for the purpose of illustrating the typical installation of Skyline system. The system is to be installed strictly in accordance with the specifications detailed in the forward section of this manual. Substrate construction to be in accordance with the Building Regulations & Statutory Requirements.

Not

e: D

o no

t pea

rce

Skyl

ine

mem

bran

e w

ith

mec

hani

cal f

astn

ers

thro

ugh

the

hori

zont

al p

lane

Mas

terW

all B

reat

her

Fra

me

Wra

p

Koolt

her

m® p

anel

Box

gu

tter

4.5m

m F

/C s

hee

t w

ith

50m

m w

idth

Sky

line

Mem

bra

ne

(to

be

app

lied

as

per

S

kylin

e S

yste

m S

pec

i�ca

tio

n)

Fib

reg

lass

rei

nfo

rcin

g m

esh

Min

imu

m 5

mm

ap

pro

ved

mes

h r

ein

forc

ed

po

lym

er m

od

i�ed

ren

der

sys

tem

Poly

styr

ene

H-G

rad

e w

edg

e

4.5m

m F

/C s

hee

t w

ith

50m

m w

idth

These details are indicative for the purpose of illustrating the typical installation of Skyline system. The system is to be installed strictly in accordance with the speci�cations detailed in the forward section of this manual. Substrate construction to be in accordance with the Building Regulations & Statutory Requirements.

All

exte

rnal

co

rner

s re

info

rced

wit

h a

lloy

ren

der

b

ead

wit

h in

teg

ral �

ber

gla

ss

mes

h r

ein

forc

ing

str

ip

SKYLINE SYSTEM / Kooltherm® PANEL:

BAL 40 RENDERED PARAPET WALL (CLOSE UP)

Fib

reg

lass

rei

nfo

rcin

g m

esh

to

cov

er g

ap

bet

wee

n a

lloy

ang

le m

esh

ret

urn

s

Mas

terW

all a

pp

rove

d 7

5mm

�xi

ng

&

50m

m b

utt

on

set

Mas

terW

all a

pp

rove

d �

xin

g

& 5

0mm

bu

tto

n s

et

Mas

terW

all a

pp

rove

d a

dh

esiv

e

Page 12: Download Construction Manual - Masterwall Australia · PDF fileNo part of this document is to be copied or reproduced without the express written permission of MasterWall Australia

12 COPYRIGHT 2017. No part of this document is to be copied or reproduced without the express written permission of MasterWall Australia Pty Ltd. 24.02.2017

These details are indicative for the purpose of illustrating the typical installation of Skyline system. The system is to be installed strictly in accordance with the specifications detailed in the forward section of this manual. Substrate construction to be in accordance with the Building Regulations & Statutory Requirements.

F/C

sh

eet

4.5m

m r

etu

rned

50

mm

into

box

gu

tter

Not

e:

Do

not p

earc

e Sk

ylin

e m

embr

ane

with

mec

hani

cal

fast

ners

thro

ugh

the

hori

zont

al p

lane

Bri

ck V

enee

r

Sky

line

mem

bra

ne

(to

be

app

lied

as

per

Sky

line

Sys

tem

Sp

eci�

cati

on

)

Min

fall

Poly

styr

ene

H-G

rad

e w

edg

e

Box

gu

tter

Tru

ss

Tim

ber

stu

d

See

Sta

nd

ard

Par

apet

Sys

tem

C

lose

Up

Det

ail f

or

�xi

ng

These details are indicative for the purpose of illustrating the typical installation of Skyline system. The system is to be installed strictly in accordance with the speci�cations detailed in the forward section of this manual. Substrate construction to be in accordance with the Building Regulations & Statutory Requirements.

Rend

er N

ote:

Re

nder

sys

tem

is to

be

poly

mer

mod

i�ed

re

nder

, ful

ly �

breg

lass

mes

h re

info

rced

with

al

kali

resi

stan

t ren

der m

esh,

com

plet

ed w

ith

desi

red

text

ure

�nis

h. It

is re

com

men

ded

that

a

dura

ble

roll-

on m

embr

ane

/ pai

nt b

e ap

plie

d to

ke

ep th

e su

rfac

e cl

ean.

SKYLINE / BRICK VENEER:

BRICK VENEER WITH SKYLINESYSTEM WATER PROOFING

Mas

terW

all a

pp

rove

d 7

5mm

xin

g &

50m

m b

utt

on

set

Page 13: Download Construction Manual - Masterwall Australia · PDF fileNo part of this document is to be copied or reproduced without the express written permission of MasterWall Australia

These details are indicative for the purpose of illustrating the typical installation of Skyline system. The system is to be installed strictly in accordance with the specifications detailed in the forward section of this manual. Substrate construction to be in accordance with the Building Regulations & Statutory Requirements.

13COPYRIGHT 2017. No part of this document is to be copied or reproduced without the express written permission of MasterWall Australia Pty Ltd.

Render Note: Render system is to be polymer modi�ed

render, fully �breglass mesh reinforced with alkali resistant render mesh, completed with

desired texture �nish. It is recommended that a durable roll-on membrane / paint be applied to

keep the surface clean.

Render Note: Render system is to be polymer modi�ed

render, fully �breglass mesh reinforced with alkali resistant render mesh, completed with

desired texture �nish. It is recommended that a durable roll-on membrane / paint be applied to

keep the surface clean.

Skyline system to be installed strictly in accordance with the speci�cations detailed in the forward section of this manual. Substrate construction to be in accordance with the Building Regulations & Statutory Requirements.

Skyline membrane (to be applied as per Skyline System Speci�cation)

Minimum 5mm approved mesh reinforced polymer modi�ed

render system

Minimum 6mm F/C sheet or compressed sheet - bonded to

brickwork with tile adhesive

Skyline parged to brick with Skyline approved adhesive

Skyline parged to brick with Skyline approved adhesive

Min. 35mm drop down

Fibreglass reinforcing mesh

Skyline membrane (to be applied as per Skyline System Speci�cation)

Minimum 5mm approved mesh reinforced polymer modi�ed

render system

Minimum 6mm F/C sheetor compressed sheet - bonded

to tile adhesive

Skyline parged to brick with Skyline approved adhesive

Skyline parged to brick with Skyline approved adhesive

Min 35mm drop down

DOUBLE BRICK PARAPET WITHOUT SLOPESKYLINE / DOUBLE BRICK:

Min 7° fall

SKYLINE / DOUBLE BRICK:

DOUBLE BRICK PARAPET WITH SLOPE

Tile adhesive

Tile adhesive

Tile adhesive

Page 14: Download Construction Manual - Masterwall Australia · PDF fileNo part of this document is to be copied or reproduced without the express written permission of MasterWall Australia

These details are indicative for the purpose of illustrating the typical installation of Skyline system. The system is to be installed strictly in accordance with the specifications detailed in the forward section of this manual. Substrate construction to be in accordance with the Building Regulations & Statutory Requirements.

14 COPYRIGHT 2017. No part of this document is to be copied or reproduced without the express written permission of MasterWall Australia Pty Ltd. 04.07.2016

Not

e:

Do

not p

earc

e Sk

ylin

e m

embr

ane

with

mec

hani

cal

fast

ners

thro

ugh

the

hori

zont

al p

lane

Sky

line

mem

bra

ne

(to

be

app

lied

as

per

Sky

line

Sys

tem

Sp

eci�

cati

on

)

Mas

on

ry w

all

Poly

mer

bas

e co

at

Poly

mer

bas

e co

at

Sky

line

par

ged

to

bri

ck w

ith

Sky

line

app

rove

d a

dh

esiv

e

Ab

el�

ex u

nd

er c

aulk

ing

, ov

er S

kylin

e m

emb

ran

e

These details are indicative for the purpose of illustrating the typical installation of Skyline system. The system is to be installed strictly in accordance with the speci�cations detailed in the forward section of this manual. Substrate construction to be in accordance with the Building Regulations & Statutory Requirements.

Allo

y ex

tern

al c

orn

er

(un

mes

hed

)

Text

ure

co

at

Co

ntr

ol J

oin

t w

ith

Po

st r

end

er c

aulk

ing

wit

h A

bel

�ex

beh

ind

fre

e o

f re

nd

er s

yste

m

Min

. 35m

m d

rop

do

wn

Co

ntr

ol j

oin

t as

co

nst

ruct

ed b

y b

rick

laye

r

SKYLINE:

MASONRY WALL CONTROL JOINTELEVATION VIEW (FRONT)

Page 15: Download Construction Manual - Masterwall Australia · PDF fileNo part of this document is to be copied or reproduced without the express written permission of MasterWall Australia

These details are indicative for the purpose of illustrating the typical installation of Skyline system. The system is to be installed strictly in accordance with the specifications detailed in the forward section of this manual. Substrate construction to be in accordance with the Building Regulations & Statutory Requirements.

15COPYRIGHT 2017. No part of this document is to be copied or reproduced without the express written permission of MasterWall Australia Pty Ltd.

These details are indicative for the purpose of illustrating the typical installation of Skyline system. The system is to be installed strictly in accordance with the speci�cations detailed in the forward section of this manual. Substrate construction to be in accordance with the Building Regulations & Statutory Requirements.

Skyline membrane (to be applied as per Skyline System Speci�cation)

Min. 10mm

Caulking from front to rear over Skyline membrane

Control joint as constructed

by bricklayer

Polymer base coat

Polymer base coat

Polymer base coat

Masonry wall

Texture coat

MASONRY WALL CONTROL JOINTSKYLINE:

PLAN VIEW (TOP)

Control joint as constructed

by bricklayer

Vertical return of box gutter

�ashing to top of brickwork

Masonry wall

Texture coat

Min. 10mm

Skyline membrane (to be applied as per Skyline System Speci�cation)

Extent of Skyline membrane onto box gutter �ashing(Min. 50mm)

Head of masonry wall

Caulking over Skyline membrane

SKYLINE:

MASONRY WALL CONTROL JOINTELEVATION VIEW (REAR)

Page 16: Download Construction Manual - Masterwall Australia · PDF fileNo part of this document is to be copied or reproduced without the express written permission of MasterWall Australia

16 COPYRIGHT 2017. No part of this document is to be copied or reproduced without the express written permission of MasterWall Australia Pty Ltd. 24.02.2017

These details are indicative for the purpose of illustrating the typical installation of Skyline system. The system is to be installed strictly in accordance with the specifications detailed in the forward section of this manual. Substrate construction to be in accordance with the Building Regulations & Statutory Requirements.

Note: Do not pearce Skyline membrane with mechanical fastners through the horizontal planel

Render note: Render system is to be polymer modi�ed render, fully �breglass mesh reinforced with alkali resistant render mesh, completed with desired texture �nish. It is recommended that a durable roll-on membrane / paint be applied to keep the surface clean.

These details are indicative for the purpose of illustrating the typical installation of Skyline system. The system is to be installed strictly in accordance with the speci�cations detailed in the forward section of this manual. Substrate construction to be in accordance with the Building Regulations & Statutory Requirements.

MasterWall® Breather Frame Wrap

MasterWall® Breather Frame Wrap

Timber stud

Skyline membrane (to be applied as per Skyline System speci�cation)

Alternative claddinge.g. weatherboard, �bre cement sheeting, aluminium panel, metal sheeting, plywood etc. (as per manufacturers speci�cations)

Timber stud

Timber stud

Waling plate

F/C sheet 4.5mm

Polystyrene wedge or framed with F/C sheet

MasterWall approved adhesive

SKYLINE SYSTEM:

CONCEALED FLASHING DETAILWATERPROOF LEDGE OR SIMILAR

Min. 35mm Skyline membrane drop down

Page 17: Download Construction Manual - Masterwall Australia · PDF fileNo part of this document is to be copied or reproduced without the express written permission of MasterWall Australia

17COPYRIGHT 2017. No part of this document is to be copied or reproduced without the express written permission of MasterWall Australia Pty Ltd.

These details are indicative for the purpose of illustrating the typical installation of Skyline system. The system is to be installed strictly in accordance with the specifications detailed in the forward section of this manual. Substrate construction to be in accordance with the Building Regulations & Statutory Requirements.

SKYLINE:

DETAIL TAPE PLACEMENT & SKYLINE MEMBRANE OVERLAP DETAIL

75 -100mm overlap

75 -100mm overlap junction at membrane joins with sealant- see speci�cations and Youtube Skyline video

These details are indicative for the purpose of illustrating the typical installation of Skyline system. The system is to be installed strictly in accordance with the speci�cations detailed in the forward section of this manual. Substrate construction to be in accordance with the Building Regulations & Statutory Requirements.

Skyline Detail Tape- see speci�cations and online video

Page 18: Download Construction Manual - Masterwall Australia · PDF fileNo part of this document is to be copied or reproduced without the express written permission of MasterWall Australia

18 COPYRIGHT 2017. No part of this document is to be copied or reproduced without the express written permission of MasterWall Australia Pty Ltd. 24.02.2017

SYSTEM CHECKLIST:

NOTES:

PRODUCT

Skyline membrane

MasterWall Panel

MasterWall Fixings

MasterWall Breather Frame Wrap

MasterWall Flashing Tape

Premium Quality Modified Liquid Sealant / Adhesive

Expandable Elastic Foam

Ableflex

DESCRIPTION

Waterproof Renderable Membrane

Precoated Polystyrene Panel (ready to render)

Screw Button Sets 100 p/box

Vapour Permeable Sarking

Self Adhesive Aluminium Tape (flashing windows & doors etc)

Premium Quality Modified Liquid Sealant

Expandable Urethane Flexible Foam (joint sealant)

Foam strip for rebated slab detail & expansion joints

SIZES

Width by request

50mm, 75mm, 100mm & 125mm

75mm

1350mm or 2700mm

75mm width

600ml sausage

700ml can

75mm width

COVERAGE

Job specification

1.2m x 2.4m (2.88m²)

300 Centres

82m² per roll

25m roll

2 per roll of flashing tape

65m² of MasterWall Panel

25m roll

Page 19: Download Construction Manual - Masterwall Australia · PDF fileNo part of this document is to be copied or reproduced without the express written permission of MasterWall Australia
Page 20: Download Construction Manual - Masterwall Australia · PDF fileNo part of this document is to be copied or reproduced without the express written permission of MasterWall Australia

24.02.2017

MasterWall Australia supports all of its products with a comprehensive Technical Advisory Service for specifiers, stockists and contractors.

Phone MasterWall with your project specifications.

Phone: (03) 9799 6565

For national technical advice and local applicators contact MasterWall.

CONTACT MASTERWALL

MasterWall Australia offers a unique range of modern insulating wall and floor construction solutions forresidential & commercial projects. www.masterwall.com.au