SPECIFICATIONS
9 - Pop-Drain
3 - UL Listed Trap Primer With VAC Breaker
13 - UL and AGA Listed, Reg Stat. High Limit Safety, ASME P&T Relief To Drain, ASHRAE 90A80 Insulation
7 - Chrome Plated Cast Brass P-Trap With Clean-Out
NOTES: 1 - Open Front Seat
8 - Open Grid Drain
2 - Wall Carrier
ITEM FIXTURE MANUFACTURER
14 - 2.5 GPM Flow Limiters
12 - Anchors, Supports Trim Complete
6 - Vacuum Breaker
10 - Angle Supply With Stops
4 - Handicap Trap Wrap
11 - 1/2 GPM Flow Limiters
5 - Bolt Caps
HWCWMODEL N0. VENTWASTE REMARKS NOTES
WC1 1.6 GPF, TRIM KIT, ADA COMPLIANT
-
1/2" 2"3"WATER CLOSET - TANK 1, 5, 6, 10, 12ZURN Z5550
L1 LAVATORY ZURN
SELF RIMMING, DELTA 520 FAUCET, VANDAL
1/2"1/2"Z5820 1.5"1.5" 4, 7, 8, 10, 11, 12RESISTANT AERATOR
S1 UTILITY SINK
SV SHOWER MIXING VALVE BRADLEY 3/4"S59-2005 3/4"
- -
WH
1
WATER HEATER STATE
50 GALLON, 76 MBH S.L. NAT GAS INPUT
3/4"3/4"SHE 50 76N
--
SEE DETAIL, 120V/1Ø, 22"DIA X 70.62"H12, 13
3"Ø PVC/CPVC COMBUSTION AIR INTAKE AND VENT
1
CP
CIRCULATION PUMP GRUNDFOS
3 GPM @ 3 FT HD, 115V/1Ø, 1/25 HP.1/2"UP 15-10 B7
- --
SEE DETAIL
MOUNT ON WALL. PROVIDE FLEXIBLE PLATED
METAL HOSE WITH SHOWER HEAD AT CENTER OF
ROOM. HEAD SHALL REACH DEEP SINK
FD FLOOR DRAIN ZURN
DEEP SEAL TRAP, BRASS GRATE
-
Z400 TYPE N
-
SEE
PLAN
SEE
PLAN
LIGHT DUTY FLOOR DRAIN DETAIL
SCALE
N.T.S.
SCALE
N.T.S. ROOF PENETRATION DETAIL
WASTE PIPE.
SEE PLAN
FOR SIZE
'P' TRAP.
SEE PLAN
FOR SIZE
LIGHT DUTY FLOOR DRAIN WITH OR
WITHOUT TRAP PRIMER AS REQUIRED
NICKEL BRONZE GRATE,
SEE NOTE NO. 2.
FINISHED FLOOR
NOTES:
SLOPE FLOOR TO FLOOR DRAIN
AS INDICATED ON CONCRETE
PLACEMENT PLAN.
1.
REFER TO PLUMBING PLAN FOR
LOCATIONS AND SIZES OF DRAINS.
2.
WALL CLEANOUT (WCO)
FLOW
FLOOR CLEANOUT (FCO)
SCALE
N.T.S. CLEANOUT DETAIL
FINISHED FLOOR
ADJUSTABLE TYPE CLEANOUT
FLUSH WITH FINISHED FLOOR
COMBINATION Y &
1/8 BEND FITTING
WASTE/VENT PIPING
PROVIDE EXTENSION IF GREATER THAN 3"
WALL PLATE, CHROME PLATED (SEE SPECIFICATIONS)
WALL OPENING SHALL BE 1" LARGER THAN PLUG DIAMETER
THREADED BRASS ROD OR MACHINE SCREW
CLEANOUT TEE WITH TAPER THREADED BRASS PLUG
STRUCTURE
INSULATION
ROOFING
2"X12" NAILER
PIPE SLEEVE
PIPE
ANCHOR
PATE DEKTITE
FLASHING SYSTEM
20 GA. GALV.
STEEL CAP
FLASHING
MIN 6" HIGH
WATERPROOF
SEAL ALL AROUND
SCALE
N.T.S. DOUBLE CLEANOUT DETAIL
SLOPE 1/8" PER FOOT
DCOTG
36" STEEL MANHOLE. PROVIDE
WITH LOCKING MECHANISM.
(TYP. FOR ALL DCOTG)
6" DEEP CONCRETE PAD,
8" BEYOND ALL SIDES OF
CLEANOUT BODIES
(TYP. FOR ALL DCOTG)
4" WASTE FROM
BUILDING. SEE PLANS
FOR CONTINUATION
CAST IRON CLEANOUT FERRULE
WITH RAISED HEAD BRASS PLUG.
LUBRICATE PLUG THREADS WITH
GREASE BEFORE INSTALLATION.
TOP OF CLEANOUT SHALL BE 2.5"
MAX BELOW TOP OF COVER.
FINISHED GRADE
TD TRENCH DRAIN ZURN
VEHICULAR RATED
- -
1.5"3"
Z-886-HD
SCALE
N.T.S.WATER HEATER DETAIL
FD
76 MBH GAS
INPUT SEE
PLANS FOR
SIZE AND
LAYOUT
1" HW OUT
THERMAL EXPANSION
TANK THERM-O-FLEX
ETC-7
SHUT-OFF
VALVE
DRAIN VALVE
3" PVC INTAKE UP THROUGH
ROOF OR SIDEWALL TO
APPROVED TERMINATION
3" CPVC VENT
UP THROUGH
ROOF OR
SIDEWALL TO
APPROVED
TERMINATION
ELECTRICAL
CHECK
VALVE
PUMP
SERVICE
VALVE (2)
1" CW IN
VACUUM RELIEF
WATTS #N36 (ABV.
TOP OF HEATER)
WH
1
50 GAL
GAS
ISOLATION
VALVE
6" DIRT LEG
CP
1
3 GPM
AQUASTAT SET TO
130° ADJUSTABLEDIELECTRIC
UNION (TYP.)
ASME P&T
RELIEF PIPED
TO 1" ABOVE FD
NOTES:
UL AND AGA LISTED, REG STAT. HIGH
LIMIT SAFETY, ASME P&T RELIEF TO
DRAIN, ASHRAE 90A80 INSULATION
ELKAY 1/2" 1/2" 1.5"1.5"
SYMMONS S-249 FAUCET
SS8136
VANDAL RESISTANT AERATOR
4, 7, 8, 9, 10, 11, 12
HC VERIFY LOCATION
HOSE CONNECTIONWOODFORD
WITH VACUUM BREAKER
-
1/2"
-
1/2"C22
HOT AND COLD WATER
3/4" HWC
(E) FINISHED GRADE
(E) GAS LINE
(E) GAS PRESSURE
(E) PIPE SIZED BY
XCEL ENERGY.
NOTE:
GAS PIPING TO BUILDING,
GAS REGUALTOR, AND
GAS METER PROVIDED
BY XCEL ENERGY.
(E) SERVICE TERMINAL
GAS METER
PLUMBING CONTRACTOR
RESPONSIBLE FOR ALL GAS
PIPING AFTER OUTLET OF GAS
METERS INTO BUILDING
ISOLATION VALVE (TYP)
(N) 4" HEADER
(E) HORAN
N.T.S.
SCALE
(E) GAS PIPING TO (E)
BUILDING SPACE
(N) 3" GAS PIPING ROUTE
UNDERGROUND 12" MINIMUM
TO NEW ADDITION. PROVIDE
GAS PIPING RATED FOR
UNDERGROUND INSTALLATION
REGULATOR
VALVE
GAS METER MANIFOLD DETAIL
TD (24'-0")
FCO
3" S/O
(E) 4" S/O
(E) FCO
(E) 4" W
4" W
4" W
3" W
3" W
3" W
DCOTG
(E) 4" W TO
SANITARY
SEWER
WCO
3" HUB DRAIN 27" AFF,
VERIFY SIZE AND
LOCATION WITH OWNER
S1
3" FD
3" V
3" V
3" V
3" V UP TO 3" VTR. SEE SHEET P2.0
3" WASTE DOWN
FROM FLOOR ABOVE
WCO
WC1
3" FD
3" FD
WCO
WCO
L1
3" VTR
2" W 3" W
3" W
3" W
2" V
2" V
2" V
3" V
3" WASTE DOWN TO
FLOOR BELOW
N.T.S.
SCALE
WASTE AND VENT PIPING DIAGRAM
TE
LE
: 3
03
.9
91
.0
99
1 F
AX
: 3
03
.9
91
.0
99
2
16
15
C
AL
IF
OR
NIA
S
TR
EE
T
SU
IT
E 3
01
DE
NV
ER
, C
OL
OR
AD
O 8
02
02
ENG
INEE
RIN
G
PRELIMINARY
NOT FOR CONSTRUCTION
FIRST FLOOR WASTE AND VENT PIPING PLAN
SCALE: 1/8" = 1'-0"
1
P1.0
GARAGE / STORAGE / STAGING
STORAGE
MUSLIM
PREP ROOM
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
(E) FCO
S1
GENERAL NOTES
ALL WASTE PIPING TO BE SLOPED AT A MINIMUM 1/8" PER FOOT.
1
VERIFY ACTUAL SIZE, LOCATION, AND INVERT OF EXISTING WASTE
AND VENT PIPING PRIOR TO CONSTRUCTION.
2
= CONNECT NEW TO EXISTING
3" FD
(E) S/O INTERCEPTOR
(E) 4" S/O(E) 4" W
(E) 4" W
(E) 4" W TO (E)
SANITARY
SEWER
(E) FCO
FCO
3" S/O
TD (24'-0")
3" W DOWN FROM FLOOR ABOVE.
SEE SHEET P2.0 FOR CONTINUATION
(E) TD (44'-8")
1THIS AREA IS EXISTING TO REMAIN, NO NEW WORK.
SHEET NOTES
3" HUB DRAIN 27" AFF, VERIFY SIZE
AND LOCATION WITH OWNER
(E) 4" W TO (E)
SANITARY
SEWER
NO "P-TRAP"
INSTALL NEW DOUBLE
CLEANOUT TO GRADE
STORAGE
(E) COOLERNEW COOLER
3" VENT UP TO
FLOOR ABOVE
WCO
3" W
3" V
C
C
B
B
A
A
1 1
3 3
2 2
REPLACE (E) 4" WASTE WITH
(N) 4" WASTE. VERIFY IN FIELD
CONNECT 4" W
TO (E) 4" W
CONNECT 4" W
TO (E) 4" W
TE
LE
: 3
03
.9
91
.0
99
1 F
AX
: 3
03
.9
91
.0
99
2
16
15
C
AL
IF
OR
NIA
S
TR
EE
T
SU
IT
E 3
01
DE
NV
ER
, C
OL
OR
AD
O 8
02
02
ENG
INEE
RIN
G
PRELIMINARY
NOT FOR CONSTRUCTION
SECOND FLOOR WASTE AND VENT PIPING PLAN
SCALE: 1/8" = 1'-0"
1
P2.0
C
C
B
B
A
A
1
3
2
STORAGE / OVERFLOW
OFFICE
OPEN PRE-NEED
FLOWER PREP.
UNI-SEX
1
1
1
1
1
1
1
1
1
1
1
1
WC1
L1
WH
1
50 GAL
3" FD
3" FD
3" W DOWN TO FLOOR BELOW. SEE
SHEET P1.0 FOR CONTINUATION
GENERAL NOTES
ALL WASTE PIPING TO BE SLOPED AT A MINIMUM 1/8" PER FOOT.1
VERIFY ACTUAL SIZE, LOCATION, AND INVERT OF EXISTING WASTE
AND VENT PIPING PRIOR TO CONSTRUCTION.
2
= CONNECT NEW TO EXISTING
1THIS AREA IS EXISTING TO REMAIN, NO NEW WORK.
SHEET NOTES
WCO
3" W
WCO
2" W
3" W
3" W
2" V
3" VTR
3" VENT FROM FLOOR
BELOW AND UP THROUGH
ROOF TO WEATHER CAP
3" W
2WATER HEATER P&T RELIEF TO DRAIN INTO FLOOR DRAIN VIA 1" AIR GAP.
2
3FURNACE CONDENSATE TO DRAIN INTO FLOOR DRAIN VIA 1" AIR GAP.
3
TE
LE
: 3
03
.9
91
.0
99
1 F
AX
: 3
03
.9
91
.0
99
2
16
15
C
AL
IF
OR
NIA
S
TR
EE
T
SU
IT
E 3
01
DE
NV
ER
, C
OL
OR
AD
O 8
02
02
ENG
INEE
RIN
G
PRELIMINARY
NOT FOR CONSTRUCTION
C
C
B
B
A
A
1 1
3 3
2 2
FIRST FLOOR DOMESTIC WATER AND NATURAL GAS PIPING PLAN
SCALE: 1/8" = 1'-0"
1
P3.0
GARAGE / STORAGE / STAGING
STORAGE
MUSLIM
PREP ROOM
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
SV
S1
GENERAL NOTES
1
2
ALL DOMESTIC WATER LINES TO BE 3/4" UNLESS OTHERWISE NOTED.
SEE SCHEDULE FOR CONNECTION SIZES.
3
WATER PIPING: MINIMUM SIZES 3/4" CW AND HW PIPING SERVING
MULTIPLE FIXTURES WITH 1/2" TO A SINGLE FIXTURE. NO 1/2" TEES
ALLOWED
= CONNECT NEW TO EXISTING
VERIFY ACTUAL SIZE AND LOCATION OF EXISTING WATER PIPING
PRIOR TO CONSTRUCTION.
1
THIS AREA IS EXISTING TO REMAIN, NO NEW WORK.
SHEET NOTES
STORAGE
(E) COOLERNEW COOLER
HC
3/4" HW
3/4" CW
1" CW DOWN FROM FLOOR ABOVE.
SEE SHEET P4.0 FOR CONTINUATION
1" HW DOWN FROM FLOOR ABOVE.
SEE SHEET P4.0 FOR CONTINUATION
1" HW
3/4" HWC UP TO
FLOOR ABOVE. SEE
SHEET P4.0 FOR
CONTINUATION
1" CW CONNECT TO (E)
1" CW IN (E) BUILDING
(E) 1" CW
1" CW UP TO FLOOR
ABOVE. SEE SHEET P4.0
FOR CONTINUATION
(E) GAS METER BY XCEL ENERGY @ 6" W.C.
METERING PRESSURE. VERIFY ADDITIONAL
CONNECTED LOAD OF 266 MBH. TOTAL
DEVELOPED LENGTH NOT TO EXCEED 250 LF.
SEE DETAIL 6 ON SHEET P0.1
3" GAS @ 6" W.C. DOWN TO 12"
BELOW GROUND MINIMUM. 266 MBH
@ 150 LF. 2,610 CODE ALLOWED MBH
4
VERIFY ACTUAL SIZE, LOCATION, DEVELOPED LENGTH, AND
CONNECTED LOAD OF EXISTING GAS PIPING PRIOR TO
CONSTRUCTION.
3" GAS @ 6" W.C. 12" BELOW
GROUND MINIMUM. 266 MBH @ 150
LF. 2,610 CODE ALLOWED MBH
FRN
2
80 MBH
3" GAS UP ABOVE GROUND ALONG INSIDE WALL @ 6" W.C. 266
MBH @ 150 LF. 2,610 CODE ALLOWED MBH. PROVIDE CAPPED 3"
GAS STUB WITH ISOLATION VALVE FOR FUTURE CONNECTION
TO CREMATION EQUIPMENT. ABOVE 3" STUB REDUCE PIPE
RISER TO 1.5" GAS UP ALONG WALL @ 6" W.C. 266 MBH @ 150
LF. 482 CODE ALLOWED MBH. ABOVE 1" TAKE OFF SHOWN FOR
FRN-2 REDUCE TO 1.25" GAS TO SECOND FLOOR, SEE SHEET
P4.0 FOR GAS SIZING NOTE AND CONTINUATION
1" GAS @ 6" W.C. 80
MBH @ 150 LF. 157
CODE ALLOWED MBH
2
PROVIDE GAS ISOLATION VALVE.
2
TE
LE
: 3
03
.9
91
.0
99
1 F
AX
: 3
03
.9
91
.0
99
2
16
15
C
AL
IF
OR
NIA
S
TR
EE
T
SU
IT
E 3
01
DE
NV
ER
, C
OL
OR
AD
O 8
02
02
ENG
INEE
RIN
G
PRELIMINARY
NOT FOR CONSTRUCTION
SECOND FLOOR DOMESTIC WATER AND NATURAL GAS PIPING PLAN
SCALE: 1/8" = 1'-0"
1
P4.0
C
C
B
B
A
A
1
3
2
STORAGE / OVERFLOW
OFFICE
OPEN PRE-NEED
FLOWER PREP.
1
1
1
1
1
1
1
1
1
1
1
1
UNI-SEX
WC1
L1
WH
1
76 MBH
= CONNECT NEW TO EXISTING
1
THIS AREA IS EXISTING TO REMAIN, NO NEW WORK.
SHEET NOTES
1" CW DOWN TO FLOOR BELOW. SEE
SHEET P3.0 FOR CONTINUATION
1" HW DOWN TO FLOOR BELOW. SEE
SHEET P3.0 FOR CONTINUATION
3/4" HWC UP FROM FLOOR
BELOW. SEE SHEET P3.0
FOR CONTINUATION
1" CW
1" CW
1" CW
2NO DOMESTIC WATER PIPES TO ROUTE THROUGH CLOSET.
1" CW UP FROM FLOOR
BELOW. SEE SHEET P3.0
FOR CONTINUATION
2
3/4" HWC
1" HW
1" HW
3
ROUTE 3" PVC INTAKE AND 3" CPVC VENT UP THROUGH ROOF TO
MANUFACTURERS APPROVED TERMINATION(S).
3
FRN
1
110 MBH
GENERAL NOTES
1
2
ALL DOMESTIC WATER LINES TO BE 3/4" UNLESS OTHERWISE NOTED.
SEE SCHEDULE FOR CONNECTION SIZES.
3
WATER PIPING: MINIMUM SIZES 3/4" CW AND HW PIPING SERVING
MULTIPLE FIXTURES WITH 1/2" TO A SINGLE FIXTURE. NO 1/2" TEES
ALLOWED
VERIFY ACTUAL SIZE AND LOCATION OF EXISTING WATER PIPING
PRIOR TO CONSTRUCTION.
4
VERIFY ACTUAL SIZE, LOCATION, DEVELOPED LENGTH, AND
CONNECTED LOAD OF EXISTING GAS PIPING PRIOR TO
CONSTRUCTION.
CP
1
3.0 GPM
1.25" GAS UP FROM FLOOR
BELOW @ 6" W.C. 186 MBH @
150 LF. 322 CODE ALLOWED
MBH. SEE SHEET P3.0 FOR
CONTINUATION.
1" GAS TO WH-1 @ 6" W.C. 76
MBH @ 150 LF. 157 CODE
ALLOWED MBH. PROVIDE GAS
ISOLATION VALVE AS SHOWN.
1" GAS TO FRN-1 @ 6" W.C. 110
MBH @ 150 LF. 157 CODE
ALLOWED MBH. PROVIDE GAS
ISOLATION VALVE AS SHOWN.
TE
LE
: 3
03
.9
91
.0
99
1 F
AX
: 3
03
.9
91
.0
99
2
16
15
C
AL
IF
OR
NIA
S
TR
EE
T
SU
IT
E 3
01
DE
NV
ER
, C
OL
OR
AD
O 8
02
02
ENG
INEE
RIN
G
PRELIMINARY
NOT FOR CONSTRUCTION