Double Box Culvert With Flared Wings - Square
-
Upload
pradeep-s-gowda -
Category
Documents
-
view
218 -
download
0
Transcript of Double Box Culvert With Flared Wings - Square
-
8/6/2019 Double Box Culvert With Flared Wings - Square
1/1
L O C A T I O N S K E T C H
1T"V
"
"G"
"E"
6"T
"B
"HT
"B"
6
"D"
E L E V A T IO N A -A
2 3Flow line Elevation (2)
FlowConst. jt.
(as shown on road section)"A" "C"A"
20"
Flow lineElevation (1)
"R" "M"
20"
S E C T IO N T H R U B O X
"TX" "S""TI"
"S" "TX"
"B
"HT
"T
(Normal to Structure)
18" (Typ.)
DETAIL "B"
2
"TX"
"TX"
3
10" (Typ.)
Fa
Rwy
3"
Const. jt.
1
"TX"
"TI"
"S" "S"
"U"
"Q"
3
"R
"M"
"N"
"P"
3"
3
"Y"
" K K "
2
Roadway or Median
2
P L A N S H O WIN G L A Y O U T D IM E N S IO N S
AFow
A
Lmiog
b
Lmiog
b
Station
1
DETAIL"B"
"F"
18" 18"
L=T
haoS
u
"E
"A"C
"A"B
"D"
DETAIL"A""T X " "TX "
10^
10
"TX"
"TX"
3" 2
DETAIL "A"
Const. jt.
"N"
Structure
G E N E R A L D A T A T A B L EVA RIA BLE EQUATION VA RIA BLE
Elev. (1) feetElev. (2) feet
EQUATION
Design Fill (*)
"B"
"S"
"M "
"HT"
"L""G"
- - -
"E"
- - -
"C"- - -- - -
2V
"TS" - - -"BS" - - -"TX" - - -"TI" - - -
- - -A"
G + 23""F" 2S + 2TX + TI
"D" R + M + N + 20"
2A + B + C + D + E
"V" HT + TS - 12"
"N""P""Q"
N(cos 20^)3" + TX(tan 10^)2V(sec 20^)TX(cos 20^)
"R""U"
"Y" TX(sin 20^)
P(cos 20^)(R + M)(tan 20^)
"KK" S + U + TI/2
"G"
3
(Normal to Roadway)
Design Loading:
Design Unit Stresses:
Design Specifications:GENERAL NOTES:
Shoulder to Shoulder Width
Sta.=Pr. Gr. Elev. at Sta.=Fill at Rdwy. at Station =
F IN A LQUANTITIESS T IM A T E D Q U A N T IT IE S
cu. yard
cu. yardpound
Class 4 Excavation
Class B-1 C oncrete (Culverts-Bridge)Reinforcing Steel (Culverts-Bridge)
D IM . D IM .
* Design fill height is the distance from topof earth fill or roadway to the top ofthe top slab.
Removal of Bridges lump sum
20^
Roadway or Median
2002 - AASHTO 17th EditionLoad Factor Design
Granular Backfill
Granular backfill
Precast Box usedCast-in-Place Box used
Note: Slope of bottom slab shall be placed atnatural stream gradient.If unsuitable material is encountered, excavationof unsuitable material and furnishing and placingof granular backfill shall be in accordance withSec 206.
The box shown below indicating whether aprecast or cip box was used should bechecked by MoDOT Construction personnel:
HS20-44 HS20 ModifiedEarth 120 #/ft.Equivalent fluid pressure30 #/ft. (Min.) - 60 #/ft. (Max.)All elevations shown are in feet unlessotherwise noted.
Class B-1 concrete fc = 4,000 psiReinforcing steel (Grade 60), fy = 60,000 psi
"Sec" refers to the sections in the standardand supplemental specifications unlessspecified otherwise.
When alternate precast box sections are used,the minimum barrel length measured along theshortest wa ll from the first joint to theoutside of the headwall, shall be 3~2".Reinforcement and dimensions for the wingsand headwalls shall be in accordance withMissouri Standard Plans drawing.Minimum c learance to reinforcing steel shallbe 1 1/2", unless otherwise shown.
Design High Water (DHW) Elev. = ___________
Backwater/Base Flood Data (100 year)
HYDROLOGIC DATA
Roadway Overtopping
High Water Elev. = _____________
Estimated Backwater = _______ ___ (ft)
Design Elev. (1 below shoulder) = ___________Design Discharge = ___________ (cfs)Design Frequency = ___________ (year)
Drainage Area = ___________ _____ (sq. mi.)
Design High Water Discharge = ______________ (cfs)
Design Discharge = _______________ (cfs)
Design High Water Frequency = _________ (year)
Outlet Velocity = _____________ (ft/sec)
M I S S O U R I H IG H W A Y S A N D T R A N S P O R T A T I O N C O M M I S S I O N
DesignedDetailedChecked Note: This drawing is not to scale. Follow dimensions. Sheet No. ofABOUT
S TA TE R O A D
STA.
BRIDGE
B . M .
STD.STD.STD.STD.
SEC/SUR TWP RGE* * *
* BR **
*
box04_dbl_sq_ fla Effective: July 2008 Supercedes: Jan. 2006
B O X 4d:\pwise_local\GABELR1\dms09884\box_dbl_tri_ref.dgn 08:33:36 AM 07/10/2008
STATE DISTRICT S H E E T N O .OUTE
JOB NO.
PROJECT NO.
C O U N TY D A TE
MO
CONTRACT ID.
"THIS MEDIA SHOULDNOT BE CONSIDERED
A CERTIFIEDDOCUMENT."