Operation Manual English
Door controlMiniMax 3 S
Operation Manual English
The door control DC MiniMax 3 S is designed for hold to run control of power operated doors. The basic version is designed for hold to run operation only, but it can be extended individually by an optional module.
Safety Directions
● In case of using DC MiniMax 3 S with a permanent mains connection, an all-pole main switch with an appropriate back-up fuse must be provided.
● With three phase motor connection an external fuse in the main supply should be max. 10A delayed.
● Before operation, check whether the permissible mains voltage range of the device corresponds to the local mains voltage.
● With three phase motor connection it must have right phase rotation.
During installation, initial operation, maintenance and testing of the DCMiniMax 3 S it is necessary to observe the safety and accident prevention regulations valid for the specific application. Only trained electrical craftsmen should work on electrical equipment.
Technical Data
Model DC MiniMax 3 S
Supply voltage 230 VAC or 400 VAC
Frequency 50 Hz
Protection class IP 54
A max. 10 A
Operation temperature - 10 C° to + 55 C°
Operation Manual English
Main board DC MiniMax 3S
ConnectorSpiral cord (X8)
OPEN/CLOSEfor installation of limit switches only
Relais output (NO)Traffic light (X9)
Terminal: selection ofsupply voltage400V/230V
Terminal: supply voltage
ConnectorMotor & safety chain
ConnectorExternal push-button station (X6)
ConnectorComfort module (X7)
PE
Terminal limit switch and
control devices
X12
Connector Keypad
Operation Manual English
Main board DC MiniMax 3S
F2S7
S4S3
Motor 230V/50Hz
Motor 400V/50Hz
400V/50Hz
230V/50Hz
Mains supply
S6
S2
S5
S9
S12
S14
S13
S15
S16
S10
S8 S11
Mains supplySelektor
X12
X6
Operation Manual English
F2 Thermal protection
K1 Contactor Close
K2 Contactor Open
K3 Traffic Light
M1 Motor connection
S01 Installation switch Open
S02 Installation switch Close
S1 Aux. limit switch Open
S2 Limit switch Open (NC)
S3 Safety limit switch Open (NC)
S4 Safety limit switch (NC)
S5 Limit switch Close (NC)
S6 Aux. limit switch Close
S7 Safety switch hand crank (NC)
S8 Safety switch slack wire (NC)
S9 Emergency stop (NC)
S10 Safety switch passor (NC)
S11 Push button STOP (NC)
S12 Push button Open (NO)
S13 Push button IMPULSE (NC) Open – STOP – Close *S14 Push button Close (NO)
S15 Photo beam (NC) *
S16 Safety edge *T1 Transformer
X1 Mains supply
X2 Motor connection
X3 Connection
X4 Selector supply voltage
X5 Connector limit switches
X6 Connector push button station
X7 Connector for plug in module
X8 Connector for spiral cord
X9 Connector for Signal-Light
X10 Selector hold to run / self-hold
X11 Connector for external brake
X12 Connector for keypad
* only active with comfort module
Operation Manual English
Wiring Diagrams
15
14
13
12
11
10
9
8
7
3
2
1
6
5
4
STOP
OPEN
CLOSE
Brown / +12V
Green / Signal
White / GND
Pro-Sec-O*OSE*
24 V DC-
+
IMPULSE*
Photobeam*
X3
2
1
X9
Relais output* for traffic light or courtesy light
9
8
7
Not connected
Electrical Safety edge
8k2
9
8
7
Pneumatic Safety edge
8k2
Not connected
DIP Switch 1 OFF
DIP Switch 7 OFF
* only possible, if comfort module is used
Max.150mA
DIP Switch 1 ON
Operation Manual English
Wiring Diagrams
15
14
13
12
11
10
STOP
OPEN
CLOSE
OPEN / STOP / CLOSE buttons(4-lead solutions)
X3
* only possible, if comfort module is used
15
14
13
12
11
10
OPEN
CLOSE
OPEN / CLOSE Key switch(3-lead solutions)
X3
54
WVU
L3
L2
L1
PE
M3~
400V / 50Hz
54
WVU
L
N
PE
M1~
230V / 50Hz
Nopen
close
L3
L2
L1
PE
Operation Manual English
Wiring Diagrams
Connector external push button stationif not used, J4 has to be bricked
Connector spiral cordif not used, J3 has to be bricked
Self-hold: J1 / J2 closedHold to run: J1 / J2 open
Self-hold is only allowed, if all safety devices necessary for the application are used !
Connector comfort module
If no module is used, J5 has to be bricked.
Not bricked
X6Close
OpenStop
J4
X8Brown(12V)
GreenSignal
WhiteGND
J3Black/yellow
STOP
J1 (AUF)
J2 CLOSE *
X10
X7J5
bricked
Operation manualFor use with DC MiniMax S English
Installation (Note without this Module Many inputs will have no function)
Plug in the board into the connector X7 Plug in Jumper J2 on connector X9
● Opto- electronic safety edge e.g. Pro-Sec-O● Electrical Safety edge● Pneumatic safety edge with test ● Automatic Closing feature● Courtesy or traffic light● Run time monitoring
Dip SwitchesClosing Time
Dip switch ON OFF
1 OPTO SE 8,2 kOhm SE
2 Automatic closing active Automatic closing deactivated
3 Automatic closing time (see table) Automatic closing time (see table)
4 Automatic closing time (see table) Automatic closing time (see table)
5 Open Push Button Go function on 4 Open Push Button Go function off
6 Prewarning Active Prewarning Deactivated
7 Pneumatic SE with testing 1 No testing
Functionality
LED DIP-Switch 1-7
DIP 3 DIP 4
15 sec. off off
30 sec. on off
60 sec. off on
120 sec. on on
Operation manualFor use with DC MiniMax S English
Overview of DIP switch functions
Dip switch Setting Funktion Connection
DIP 1 OFF Evaluation for 8,2 Kohm closing safety edgeEvaluation for pneumatic closing safety edge in connection with an 8,2KOhm resistance
X3 Terminal 7 + 8
DIP 1 ON Evaluation for OPTO closing safety edge X3 Terminal 7 + 8 + 9
DIP 2 OFF Automatic closing timer is switched off
DIP 2 ON Automatic closing timer is switched on.From the OPEN end position, the door closes automatically after the programed door-open duration expires.
Basic funktions when automatic closing timer is switched on● If the photocell barrier is interrupted during
closing, the door stopts and then opens again. The door open duration starts anew.
● If the photocell barrier is interrupted during the door open duration, the door open duration starts anew.
● If the closing safety edge systems is activated during closing, the door stops and then opens again. The door open duration starts anew. If the closing safety edge device is activated three times during an cycle, the door does not close automatically again.
DIP 3DIP 4
Automatic closing timeSee table
DIP 5 OFF Open push button GO funktion offThe OPEN pushbutton only opens a door.
DIP 5 ON Open push button GO funktion onThe OPEN pushbutton opens a door, reversing a closing door.
Operation manualFor use with DC MiniMax S English
Overview of DIP switch functions
Dip switch Setting Funktion Connection
DIP 6 OFF Pre warning light function is switched on.Traffic light (red)
Potential-free switching contact K3, terminal block X9, terminals 1+2 for connecting an external light source.
DIP 6 ON Pre Warning function is switched on when the OPEN command is given.With the yard light setting, the light then stays on for 2 minutes.
Potential-free switching contact K3, terminal block X9, terminals 1+2 for connecting an external light source.
DIP 7 OFF Pressure switch testing is not switched on.The pressure switch is not tested at the CLOSED end position.
DIP 7 ON Pressure switch testing is switched on.The pressure testing is carried out with the door at the CLOSED end position.For this, the pressure switch contact must be broken for a moment as the door touches the ground.
Operation manualFor use with DC MiniMax S English
LED Signals
1. The testing of the pneumatic safety edge takes place in the lower door position. Please ensure that the safety edge is activated in the lower door position. The Aux. Limit switch Close has to be used.
2. 2 minute night light period is activated by every movement of the door.
3. Red traffic light without prewarningprewarning 3sec. flashing before automatic closingpermanent on during the movement, 5 sec. post illumination period
4. Dip switch 4 "ON" = GO function on ( OPEN PUSHBUTTON ). The OPEN pushbutton opens a door, reversing a closing door. DIP switch 4 OFF, the OPEN pushbutton only opens a door.
LED flashing Operating state
LED 1 x flashing Safety edge actuated
LED 2 x flashing Photobeam activated / error, Safety edge error or DIP 1 setting wrong
LED 3 x flashing Primary safety device open or faulty
LED 4 x flashing Runtime error
LED fast flashing Automatic closing time has been started
XX
XX
X V
1.1
Operation manualFor use with DC MiniMax S
Radio Card, Install and Wiring, Open Only closing o n timer
X1
2
X6
Red = PowerBlack = Open Only
See Next Page if Impulse mode is needed,
To Program Remotes press and release SW1 (located next to Red LED on top edge of board)Then press and release the required button on the remote To Clear All codes press and hold for 10 Seconds,
The Remote should never be used without a monitored safety edge being fitted
Operation manualFor use with DC MiniMax S
Radio Card, Install and Wiring, Impulse operation, (OPEN-STOP-CLOSE)
X1
2
X6
Red = PowerBlack = Impulse Terminals
Extra Caution to be taken if untrained users have access to the door as the door may close if that is the next selection on the cycle.
To Program Remotes press and release SW1 (located next to Red LED on top edge of board)Then press and release the required button on the remote To Clear All codes press and hold for 10 Seconds,
The Remote should never be used without a monitored safety edge being fitted.