152
-
153
-
154154
PROFILE
EDGE DETAIL
45
mm
15mm
FEATURES AND BENEFITS• Narrow-profile, slotted grid system with 6.35mm reveal provides streamlined appearance.• Reveal accommodates partition attachments and pendant-mounted light fixtures.• Mitered intersections offer a clean, tailored appearance.• Complies with all national code requirements, including fire-rated assemblies up to one hour.• Optional integrated air diffuser. • Custom colors available.• High recycled content (HRC) available.• ICC-ES evaluated for seismic installations (ESR-1222).
APPLICATIONS• Fire-rated interior general-use areas• All interior general-use areas
VISIT USGME.COM TO ORDER SAMPLES
FLAT WHITE050
GRID COLORS
USG DONN® BRAND FINELINE® DXF™/DXLF™ACOUSTICAL SUSPENSION SYSTEM
FINELINE - FLFINELINE BEVELED - FLB
SILVER STAIN 002
FLAT BLACK9005
-
155
Main Runner 221DXBW01NZ
Long Cross Tee 221DXF003NZ
Short Cross Tee 221DXF004NZ
PRODUCT INFORMATION
Wall Angle
24mm
15mm
SUSPENSIONOPTIONS
20mm
20mm 20mm
20mm
Adjustable Hanger Suspension Wire Angle Section
DescriptionNr Profile Height
ComponentLengthItem Reference
12345
Load (1220MM Spacing)
Main Runner 221DXBW01NZ 78KG/M 45MM 3600/3660MM Long Cross Tee 221DXF003NZ 78KG/M 45MM 1200/1220MM Short Cross Tee 221DXF004NZ 78KG/M 45MM 600/610MM Wall Angle 802MT3600 24MM 3600MMWall Angle Shadowline 802MS3600 - 802MS164L 19/9MM - 20/20MM
PHYSICAL DATA MaterialMin. G30 hot-dipped galvanized steel body and cap. Baked-on polyester paint.
InstallationInstall according to ASTM C636, ASTM E580 and USG requirements.
LimitationsFor exposed grids in non-fire-rated, high-humidity applications, use USG Donn® Brand Fineline® DXFEV™ G90 painted or USG Donn® Brand ZXLA™ painted suspension systems. For exterior applications, the suspension system should be reviewed by a structural engineer.
ASTM Load ComplianceClassified as Light, Intermediate or Heavy Duty when tested in accordance with ASTM C635.
75mm 150mm 150mm 150mm
3600 mm
-
156156
PROFILE
EDGE DETAIL
46
.5m
m
7.1
5m
m
15mm
4.75mm
FEATURES AND BENEFITS• Narrow-profile grid system with double 3.175mm reveal.• Seamless reveal at intersections.• Meets or exceeds all national code requirements including seismic.• Compatible with USG Logix™ Integrated System.• Custom colors available.• ICC-ES evaluated for seismic installations (ESR-1222).• G30 hot-dipped galvanized steel body and cap inhibits red rust.• All USG Donn® Brand Identitee® DXI™ items have High Recycled Content (HRC).• Metric sizes available.• Proprietary cap lance allows a variety of color and coating options to meet unique project requirements.
APPLICATIONS• All interior general-use areas• USG Logix™ Integrated System
VISIT USGME.COM TO ORDER SAMPLES
FLAT WHITE050
BEIGE142
TAUPE107
SILVER STAIN002
PARCHMENT103
STRAW 143
CHARCOAL534
MIST053
MANILA246
SANDSTONE090
FLAT BLACK205
SILVER STONE052
GRID COLORS
USG DONN® BRAND IDENTITEE® DXI™ACOUSTICAL SUSPENSION SYSTEM
FINELINE BEVELED - FLB FINELINE - FL
-
157
Main Runner DXI26HRC
Long Cross Tee DXI424HRC
Short Cross Tee DXI224HRC
PRODUCT INFORMATION
Wall Angle
24mm
15mm
SUSPENSIONOPTIONS
20mm
20mm 20mm
20mm
Adjustable Hanger Suspension Wire Angle Section
DescriptionNr Profile Height
ComponentLengthItem Reference
12345
Load (1220MM Spacing)
Main Runner DXI26HRC 78KG/M 46.5MM 3600/3660MM Long Cross Tee DXI424HRC 78KG/M 46.5MM 1200/1220MM Short Cross Tee DXI224HRC 78KG/M 46.5MM 600/610MM Wall Angle 802MT3600 46.5MM 3600MMWall Angle Shadowline 802MS3600 - 802MS164L 19/9MM - 20/20MM
PHYSICAL DATA MaterialMin. G30 hot-dipped galvanized steel body and cap. Baked-on polyester paint.
InstallationInstall according to ASTM C636, ASTM E580 and USG requirements.
LimitationsPlease refer to USG Donn® Brand AX™ or ZXLA™ for exposed suspension systems in non-fire-rated, high-humidity applications. Interior applications only.
Additional accessories1. Load transfer bracket—use DXI/DXT26LTB.2. Partition attachment—use PAC9-6.3. Lift fixture clip—use LFC.
75mm 150mm 150mm 150mm
3600 mm
-
158158
SQUARE EDGE - SQ
SHADOWLINE BEVELED - SLB
SHADOWLINE TAPERED - SLT
PROFILE
EDGE DETAIL
38
mm
24mm
FEATURES AND BENEFITS• Main tees are designed to expand at the fire lance in the event of a fire. This maintains the structural integrity of the ceiling and holds tiles in place• DONN® Brand DX®/DXL™ T24 Heavy Duty - Fire Rated feature a body and cap made of G30 hot-dip galvanized steel with pre- painted 24mm width capping to ensure that the cap remains attractive and rust-free• Four-step coating process that outperforms in paint adhesion and corrosion resistance, as proven by industry-standard salt spray tests conducted by an Independent laboratory• Safe, fast and simple to install & easily accessible• Maximum economy and design simplicity• Cross-tees with override-ends resist twisting and give professionally finished look with no exposed steel edges• Patented QUICK-RELEASETM clip design: demountable without tools• Compatible with Square, SLT and SLB ceiling tiles edges• Audible Click means you know when tees are connected• Exceed load compliance specifications as per ASTM C 635• Available in metric and imperial sizes
APPLICATIONS• Fire-rated interior general-use area• Logix™ Integrated Ceiling Systems
VISIT USGME.COM TO ORDER SAMPLES
FLAT WHITE9010
LIMED OAK
GREY 9006
CLASSIC BEECH
BLACK9005
EXOTIC WALNUT
FLAT BLACK9005
GRID COLORS
USG ME DONN® BRAND ACOUSTICAL SUSPENSION SYSTEM DX®/DXL™ T24 HEAVY DUTY - FIRE RATED
-
159
Main Runner 801DXL3600
Long Cross Tee 803DX1200H38
Short Cross Tee 804DX600H38
MAXIMUM ALLOWED WEIGHT OF TILES PER M2
Main runner at 1200mm Main runner at 600mm
23.7 23.9 - -
23.7 23.9 55.9 56.3
12.8 12.9 26.3 26.6
4.6 4.8 10 10.3
800
1000
1200
1500
Hanger distance (mm) 600x600 600x1200 600x600 600x1200
DescriptionNr Item Reference Profile Height
ComponentLengthMetric
12345
ImperialMain Runner 801DXL3600 801DXL3660 38MM 3600/3660MM Long Cross Tee 803DX1200H38 803DX1220H38 38MM 1200/1220MM Short Cross Tee 804DX600H38 804DX610H38 38MM 600/610MM Wall Angle 802MT3600 22MM 3600MMWall Angle Shadowline 802MS3600 - 802MS164L 19/9MM - 20/20MM
PRODUCT INFORMATION
SUSPENSIONOPTIONS
Wall Angle
20mm
20mm 20mm
20mm
Adjustable Hanger Suspension Wire Angle Section
22mm
19mm
-
160160
SQUARE EDGE - SQ
FINELINE - FL
FINELINE BEVELED - FLB
PROFILE
EDGE DETAIL
38
mm
15mm
FEATURES AND BENEFITS• Main tees are designed to expand at the fire lance in the event of a fire. This maintains the structural integrity of the ceiling and holds tiles in place• DONN® Brand DX®/DXL™ T24 Heavy Duty - Fire Rated feature a body and cap made of G30 hot-dip galvanized steel with pre- painted 24mm width capping to ensure that the cap remains attractive and rust-free• Four-step coating process that outperforms in paint adhesion and corrosion resistance, as proven by industry-standard salt spray tests conducted by an Independent laboratory• Safe, fast and simple to install & easily accessible• Maximum economy and design simplicity• Cross-tees with override-ends resist twisting and give professionally finished look with no exposed steel edges• Patented QUICK-RELEASETM clip design: demountable without tools• Compatible with Square, FLB and FL ceiling tiles edges• Audible Click means you know when tees are connected• Exceed load compliance specifications as per ASTM C 635• Available in metric and imperial sizes
APPLICATIONS• Fire-rated interior general-use areas• Logix™ Integrated Ceiling Systems
VISIT USGME.COM TO ORDER SAMPLES
FLAT WHITE9010
LIMED OAK
GREY 9006
CLASSIC BEECH
BLACK9005
EXOTIC WALNUT
FLAT BLACK9005
GRID COLORS
USG ME DONN® BRAND ACOUSTICAL SUSPENSION SYSTEM DX®/DXL™ T15 CENTRICITEE
-
161
Main Runner 801DXLT15-3600
Long Cross Tee 803DXT15-1200H38
Short Cross Tee 803DXT15-600H38
MAXIMUM ALLOWED WEIGHT OF TILES PER M2
Main runner at 1200mm Main runner at 600mm
24 24.2 - -
24 24.2 54 54.2
12.4 12.5 25.5 25.7
4.5 4.7 9.8 10
800
1000
1200
1500
Hanger distance (mm) 600x600 600x1200 600x600 600x1200
DescriptionNr Item Reference Profile Height
ComponentLengthMetric
12345
ImperialMain Runner 801DXLT15-3600 801DXLT15-3660 38MM 3600/3660MM Long Cross Tee 803DXT15-1200H38 803DXT15-1220H38 38MM 1200/1220MM Short Cross Tee 803DXT15-600H38 803DXT15-610H38 38MM 600/610MM Wall Angle 802MT15-3600 24MM 3600MMWall Angle Shadowline 802MS3600 - 802MS164L 19/9MM - 20/20MM
PRODUCT INFORMATION
Wall Angle
24mm
15mm
SUSPENSIONOPTIONS
20mm
20mm 20mm
20mm
Adjustable Hanger Suspension Wire Angle Section
75mm 150mm 150mm 150mm
3600 mm
-
162162
SQUARE EDGE - SQ
SHADOWLINE BEVELED - SLB
SHADOWLINE TAPERED - SLT
PROFILE
EDGE DETAIL
38
mm
24mm
VISIT USGME.COM TO ORDER SAMPLES
FLAT WHITE9010
LIMED OAK
GREY 9006
CLASSIC BEECH
BLACK9005
EXOTIC WALNUT
FLAT BLACK9005
GRID COLORS
FEATURES AND BENEFITS• DONN® Brand DX®/DXL™ T24 Heavy Duty feature a body and cap made of G30 hot-dip galvanized steel with pre-painted 24mm width capping to ensure that the cap remains attractive and rust-free• Four-step coating process that outperforms in paint adhesion and corrosion resistance, as proven by industry-standard salt spray tests conducted by an Independent laboratory• Safe, fast and simple to install & easily accessible• Maximum economy and design simplicity• Cross-tees with override-ends resist twisting and give professionally finished look with no exposed steel edges• Patented QUICK-RELEASETM clip design: demountable without tools• Compatible with Square, SLT and SLB ceiling tiles edges• Audible Click means you know when tees are connected• Exceed load compliance specifications as per ASTM C 635• Available in metric and imperial sizes
APPLICATIONS• Interior general-use areas• Logix™ Integrated Ceiling Systems
USG ME DONN® BRAND ACOUSTICAL SUSPENSION SYSTEM DX®/DXL™ T24 HEAVY DUTY
-
163
MAXIMUM ALLOWED WEIGHT OF TILES PER M2
Main Runner 801DX3600H38
Long Cross Tee 803DX1200H38
Short Cross Tee 804DX600H38
Main runner at 1200mm Main runner at 600mm
23.2 23.5 - -23.5 23.5 46.8 48.612.3 12.4 24.6 25.24.5 4.6 9.7 9.9
800100012001500
Hanger distance (mm) 600x600 600x1200 600x600 600x1200
DescriptionNr Item Reference Profile Height
ComponentLengthMetric
12345
ImperialMain Runner 801DX3600H38 801DX3660H38 38MM 3600/3660MM Long Cross Tee 803DX1200H38 803DX1220H38 38MM 1200/1220MM Short Cross Tee 804DX600H38 804DX610H38 38MM 600/610MM Wall Angle 802MT3600 22MM 3600MMWall Angle Shadowline 802MS3600 - 802MS164L 19/9MM - 20/20MM
PRODUCT INFORMATION
SUSPENSIONOPTIONS
Wall Angle
20mm
20mm 20mm
20mm
Adjustable Hanger Suspension Wire Angle Section
22mm
19mm
-
164164
SQUARE EDGE - SQ
FINELINE - FL
FINELINE BEVELED - FLB
PROFILE USG DONN® BRAND AX™ USG DONN® BRAND AXCE™
EDGE DETAIL
38
mm
38
mm
24mm 24mm
FEATURES AND BENEFITS• Meets 2018 Guidelines For Healthcare Facilities.• Noncorrosive aluminum 24mm exposed grid system with stainless steel clip, ideal for high-humidity or wet-cleaned areas.• Capable of withstanding cleaning and/or disinfecting chemicals as tested in accordance with ASTM D5402.• Tested for environmental conditions in accordance with ASTM C635.• Aluminum components can be used in nonmagnetic environments and meet USDA/FSIS requirements.• Cross-tee override-ends resist twisting and give a professionally finished look.• Proprietary stainless steel Quick-Release™ clip.• Up to 90% recycled content.• Factory applied, white closed cell foam gasket.
APPLICATIONS• Healthcare facilities, restricted and semi-restricted areas• MRI rooms• Magnetic-free zones• High-humidity areas• Food processing areas• Certified to meet ISO 14644-1 Class 5 (Fed. Standard 209E Class 100)
VISIT USGME.COM TO ORDER SAMPLES
FLAT WHITE050
GRID COLORS
USG DONN® BRAND AX™/AXCE™ACOUSTICAL SUSPENSION SYSTEM
-
165
Main Runner AX26/AXCE26
Long Cross Tee AX224/AXCE224
Short Cross Tee AX424/AXCE424
PHYSICAL DATA MaterialDouble-web aluminum tee with aluminum cap and stainless steel Quick-Release™ clip. Baked-on polyester paint or powder-coated finish.
InstallationInstall according to ASTM C636, ASTM E580 and USG requirements.
LimitationsNon-fire-rated applications only. Finish is not UV-resistant; should not be installed where direct exposure to sun or weather will occur. Indirect exposure to severe environmental conditions may shorten the lifespan of the product. The gasket face applied to USG Donn® Brand AXCE™ contains a protective strip that must be removed prior to panel installation. The standard gasket is not recommended for installations with metal panels. If metal panels are desired, a special gasket suitable for metal panels may be applied to the USG Donn® Brand DXACE™ suspension system through special order.
ASTM Load ComplianceClassified as Light, Intermediate or Heavy Duty when tested in accordance with ASTM C635.
DescriptionNr Profile Height
ComponentLengthItem Reference
1234
Load (1220MM Spacing)
Main Runner AX26/AXCE26 35KG/M 38MM 3600/3660MM Long Cross Tee AX224/AXCE224 35KG/M 38MM 1200/1220MM Short Cross Tee AX424/AXCE424 35KG/M 38MM 600/610MM Wall Angle M7A/ M7ACE 22MM 3660MM
PRODUCT INFORMATION
Wall Angle
SUSPENSIONOPTIONS
Adjustable Hanger
Aluminum
22mm
22mm
-
166166
SQUARE EDGE - SQ
PROFILE
EDGE DETAIL
FEATURES AND BENEFITS• Meets 2018 Guidelines for Healthcare Facilities.• Grid system with factory-applied white, closed-cell foam gaskets for controlled-environments.• Min. G30 hot-dipped galvanized body provides corrosion protection.• Supports Clean Room HEPA filters and lights.• ICC-ES evaluated for building code compliance and seismic installations (ICC-ESR-1222).• Capable of withstanding cleaning and/or disinfecting chemicals as tested in accordance with ASTM D402
APPLICATIONS• Clean Rooms• Hospitals• Food processing areas• Healthcare facilities, restricted and semi-restricted areas• Certified to meet ISO 14644-1 Class 5-8 (Fed. Standard 209E Class 100- 100,000
VISIT USGME.COM TO ORDER SAMPLES
FLAT WHITE050
GRID COLORS
USG DONN® BRAND CE™ACOUSTICAL SUSPENSION SYSTEM
42m
m
24mm
-
167
Main Runner DXWCE26/DXCE24
Long Cross Tee DXWCE224
Short Cross Tee DXWCE424
PRODUCT INFORMATION
Wall Angle
SUSPENSIONOPTIONS
Adjustable Hanger Suspension Wire Angle Section Hold Down Clip
DescriptionNr Profile Height
ComponentLengthItem Reference
1234
Load (1220MM Spacing)
Main Runner MEDXCE24/DXCE24 78KG/M 42MM 3600/3660MM Long Cross Tee MEDXCE424 78KG/M 38MM 1200/1220MM Short Cross Tee MEDXCE216 78KG/M 38MM 600/610MM Wall Angle M7CE 22MM 3660MM
22mm
22mm
PHYSICAL DATA MaterialMin. G30 hot-dipped galvanized steel body and cap. Baked-on polyester paint.
InstallationInstall according to ASTM C636, ASTM E580 and USG requirements. Class 5-8 (Fed. Standard 209E Class 100-100,000) installations require hold-down clips and US28CE molding. Install a L15 hold-down clip within 76mm of each panel corner. For a 610mm x 1220mm system install an additional L15 hold-down clip centered on the 1220mm side. Border panels shall have a C-8 hold-down clip within 76mm of each panel corner. For a 610mm x 1220mm system install an additional C-8 hold-down clip centered on the 1220mm side. Alternative assemblies and installation methods may be utilized when approved by the authority having jurisdiction.
LimitationsInterior applications only. The gasket face contains a protective strip that must be removed prior to panel installation. The standard gasket is not recommended for installations with metal panels. If metal panelsare desired, a special gasket suitable for metal panels may be applied to the USG Donn® Brand CE™ Acoustical Suspension System through special order.
ASTM Load ComplianceClassified as Light, Intermediate or Heavy Duty when tested in accordance with ASTM C635.
38mm
38mm
-
168168
SQUARE EDGE - SQ
SHADOWLINE BEVELED - SLB
SHADOWLINE TAPERED - SLT
PROFILE
EDGE DETAIL
33
mm
24mm
USG ME DONN® BRAND ACOUSTICAL SUSPENSION SYSTEM DX®/DXL™ T24 INTERMEDIATE DUTY
VISIT USGME.COM TO ORDER SAMPLES
FLAT WHITE9010
LIMED OAK
GREY 9006
CLASSIC BEECH
BLACK9005
EXOTIC WALNUT
FLAT BLACK9005
GRID COLORS
FEATURES AND BENEFITS• DONN® Brand DX®/DXL™ T24 Intermediate Duty feature a body and cap made of G30 hot-dip galvanized steel with pre-painted 24mm width capping to ensure that the cap remains attractive and rust-free• Four-step coating process that outperforms in paint adhesion and corrosion resistance, as proven by industry-standard salt spray tests conducted by an Independent laboratory• Safe, fast and simple to install & easily accessible• Maximum economy and design simplicity• Cross-tees with override-ends resist twisting and give professionally finished look with no exposed steel edges• Patented QUICK-RELEASETM clip design: demountable without tools• Compatible with Square, SLT and SLB ceiling tiles edges• Audible Click means you know when tees are connected• Exceed load compliance specifications as per ASTM C 635• Available in metric and imperial sizes
APPLICATIONS• Interior general-use areas• Logix™ Integrated Ceiling Systems
-
169
MAXIMUM ALLOWED WEIGHT OF TILES PER M2
Main runner at 1200mm Main runner at 600mm
23.2 23.5 - -
23.2 23.5 46.5 47.6
11.6 11.6 23.2 23.4
4.5 4.6 9.7 9.9
800
1000
1200
1500
Hanger distance (mm) 600x600 600x1200 600x600 600x1200
Main Runner 801DX3600H33
Long Cross Tee 803DX1200H25
Short Cross Tee 803DX600H25
PRODUCT INFORMATION
DescriptionNr Item Reference Profile Height
ComponentLengthMetric
12345
ImperialMain Runner 801DX3600H33 DX3660LD 33MM 3600/3660MM Long Cross Tee 803DX1200H25 803DX1220H25 25.5MM 1200/1220MM Short Cross Tee 803DX600H25 803DX610H25 25.5MM 600/610MM Wall Angle 802MT3600 22MM 3600MMWall Angle Shadowline 802MS3600 - 802MS164L 19/9mm - 20/20mm
SUSPENSIONOPTIONS
Wall Angle
20mm
20mm 20mm
20mm
Adjustable Hanger Suspension Wire Angle Section
22mm
19mm
-
VISIT USGME.COM TO ORDER SAMPLES
FLAT WHITE9010
LIMED OAK
GREY 9006
CLASSIC BEECH
BLACK9005
EXOTIC WALNUT
FLAT BLACK9005
SQUARE EDGE - SQ
SHADOWLINE BEVELED - SLB
SHADOWLINE TAPERED - SLT
170170
PROFILE
EDGE DETAIL
FEATURES AND BENEFITS• DONN® Brand DX®/DXL™ T24 Light Duty feature a body and cap made of G30 hot-dip galvanized steel with pre-painted 24mm width capping to ensure that the cap remains attractive and rust-free• Four-step coating process that outperforms in paint adhesion and corrosion resistance, as proven by industry-standard salt spray tests conducted by an Independent laboratory• Safe, fast and simple to install & easily accessible• Maximum economy and design simplicity• Cross-tees with override-ends resist twisting and give professionally finished look with no exposed steel edges• Patented QUICK-RELEASETM clip design: demountable without tools• Compatible with Square, SLT and SLB ceiling tiles edges• Audible Click means you know when tees are connected• Exceed load compliance specifications as per ASTM C 635• Available in metric and imperial sizes
APPLICATIONS• Interior general-use areas• Logix™ Integrated Ceiling Systems
USG ME DONN® BRAND ACOUSTICAL SUSPENSION SYSTEM DX®/DXL™ T24 LIGHT DUTY
GRID COLORS
30
mm
24mm
-
171
DescriptionNr Item Reference Profile Height
ComponentLengthMetric
12345
PRODUCT INFORMATION
SUSPENSIONOPTIONS
MAXIMUM ALLOWED WEIGHT OF TILES PER M2
ImperialMain Runner 801DX3600H30 801DX3660H30 30MM 3600/3660MM Long Cross Tee 803DX1200H25 803DX1220H25 25.5MM 1200/1220MM Short Cross Tee 804DX600H25 804DX610H25 25.5MM 600/610MM Wall Angle 802MT3600 22MM 3600MMWall Angle Shadowline 802MS3600 - 802MS164L 19/9mm - 20/20mm
Main runner at 1200mm Main runner at 600mm
20.9 21.2 - -
20.9 21.2 41.9 42.9
10.5 10.5 20.9 20.9
4.1 4.2 8.7 8.9
800
1000
1200
1500
Hanger distance (mm) 600x600 600x1200 600x600 600x1200
Wall Angle
Main Runner 801DX3600H30
Long Cross Tee 803DX1200H25
Short Cross Tee 804DX600H25
20mm
20mm 20mm
20mm
30
24
3600 mm
Adjustable Hanger Suspension Wire Angle Section
22mm
19mm
-
172
GRID EDGE DETAILS
DONN® DX is the most widely specified grid in Middle East. It includes a wide range of profiles and colors and is fully compatible with all USG Boral ME ceiling tiles as well as most third party brands. Precision design and quality manufacturing ensure both structural and aesthetic integrity in all ceiling designs. USG Boral ME offers the following suspension system and edge details options. Select a suspension system and match it with a corresponding panel edge details, or vice versa, to assure proper system fit and assembly.
EDGE DETAIL SLT EdgeSQ Edge SL Edge FL Edge Pedestal (ILT Edge)
Concealed BESK Edge
Concealed S-BESK Edge
Concealed D-BESK Edge
GRID SYSTEM
DX®/DXL™ T24 LIGHT DUTY
DX®/DXL™ T24 INTERMEDIATE DUTY
DX®/DXL™ T24 HEAVY DUTY
DX®/DXL™ T24 HEAVY DUTY -FIRE RATED
DX®/DXL™ T15 CENTRICITEE
AX™/AXCE™
CE™
FINELINE® DXF™/DXLF™
IDENTITEE® DXI™
DONN® CONCEALED T,Z
DONN CONCEALED C,L
FLB Edge
-
173
• Determine the maximum allowable ceiling weight for the chosen Main Tee and hanger spacings from Graph.• Determine the maximum allowable ceiling weight for the chosen Cross Tee spacing from table.• The maximum allowable gross weight is the lower of the values from step 1 and 2.• Note that any heavy lighting, or other mechanical fixtures should be independently supported.• Seismic considerations for in-plane loads may take precedence in determining the required section (refer USG Boral ME Representative for details).
Notes: • Values are based on simple span tests in accordance with recognized International Standard ASTM C635. Higher values can often be attained by allowing for the effect of continuous spans, the actual increase being subject to span arrangements. Please contact USG Boral ME Interiors for guidance.• For cross-nogged configurations e.g.: where a 1200x600 mm panel runs parallel with the main tee, the spacing values should be used as for 1200x1200mm module.• Where main tees are at 1200mm centers, creating a 600x600mm configuration does not significantly increase load carrying limits.
Main tees
LOADINGS - DONN® DX 24MM EXPOSED GRID
CEILING MASSKG/M2
Cross Tees
DONN DX Component Point Load kg
DONN DX Component Point Load kg
DONN DXCross Tee TypeDX600L MDX1200H 30DX1200L M
Main TeeDX3600H 16.8DX3600IM* 11.6Main TeeDX600LM 35.4DX1200LM 16.7DX1200LM 5.9
Main TeeDX3600H 7.9DX3600IM* 7.0Main TeeDX600LM 13.2DX1200LM 7.9DX1200LM 4.1
Cross Tee Spacing (m)0.640.028.09.8
1.229.514.04.9
Use of Maximum Allowable Gross Ceiling Weight Charts:
Uniform Loads - kg/lm (linear metre)Uniform loads are loads that are transferred evenly along a given tee. The maximum load is the combined load on both sides of the tee.Example:A 1200 x 600 light fitting weighing 12.6 kg applies a load of 3.5 kg/lm (1.2 + 0.6 + 1.2 + 0.6 = 3.6 lm therefore 12.6 kg / 3.6 lm = 3.5 kg/lm) A 1200 x 600 ceiling panel weighing 3.6 kg applies a load of 1 kg /lm The combined load of light and ceiling panel is 4.5 kg/lm. The maximum allowable uniform load is the lesser of either main or cross tee values
Point Loads - kgPoint loads are loads that transfer to a tee at a single point (or several points) over a very small area. The weakest point is assumed to be mid span. main tees are based on a 1200mm span.
The maximum allowable point load is the lesser of either main or cross tee values.
*Hanger spacing @ 1200mm OC
*Hanger spacing @ 1200mm OC
-
DONN® SUSPENSION SYSTEM SEISMIC SOLUTIONS
174
Categories D, E, and F Category C as per IBC
Since 1957 DONN® brand suspension systems have set the standard, using the strongest gauge steel to produce the tightest systems available with the greatest lateral and torsional stiffness. Building on this commitment to quality, USG teamed with the University at Buffalo (SUNY), the Department of Civil, Structural and Environmental Engineering – Structural Engineering and Earthquake Simulation Laboratory (SEESL) and the Earthquake Engineering Research Center (EERC) University of California, Berkeley to conduct full-scale seismic testing to evaluate and qualify the seismic performance of these systems. This testing proved that DONN® suspension systems provide a superior code-compliant solution to meeting International Building Code (IBC) requirements, including installations in Categories D, E and F, and Category C. USG is the only manufacturer to team with two separate earthquake engineering laboratories to qualify the performance of our systems.
When seismic requirements are a critical design issue, architects, contractors and building officials can rely onDONN® suspension systems to:• Meet or exceed all national code requirements with 22mm wall molding.• Fulfill requirements for IBC seismic design categories C, D, E, and F.• Provide evidence of compliance (and greatly exceed) ICC Evaluation Service, Inc. (ICC-ES) AC156 and AC368 requirements.• Offer an aesthetically attractive option to traditional 5mm angle molding.• Provide approved solutions certified with the maximum m2. weights accommodating complete ceilings systems.• Offer compliant systems tested and verified by two separate earthquake engineering laboratories.• Offer a seismic clip laboratory-tested to greatly exceed all structural requirements including tension, compression & tee fallout.
Seismic testing typically focuses primarily on the suspension system itself. Any ceiling panel can be installed in the test assembly regardless of how little it weighs, and components such as light fixtures and air handling equipment are usually excluded. In practical application, however, the suspension system must support and carry the weight of a fully functional ceiling system, including ceiling panels that can weigh as much as 1kg m2./sq. Therefore, USG tested suspension systems with weights commensurate with those found in real-world installations, including light fixtures and air handling equipment, using a wide variety of the ceiling panels that USG Boral ME offers. Full-scale testing performed at the University at Buffalo (SUNY) the department of Civil, Structural and Environmental Engineering – Structural Engineering and Earthquake Simulation Laboratory (SEESL) and the Earthquake Engineering Research Center (EERC) University of California, Berkeley certifies that USG Boral ME IBC-compliant assemblies are able to accommodate loads commensurate with those found in real-world installations.
SEISMIC QUALIFICATION /
SPECIFICATIONS
Maximum Ceiling System Weight Tested
USG Boral ME
-
USG Boral ME Exceeds AC156 Test Criteria
175
The USG figures presented are based on full-scale testing and evaluation performed at the University at Buffalo (SUNY) the department of Civil, Structural and Environmental Engineering – Structural Engineering and Earthquake Simulation Laboratory (SEESL) and the Earthquake Engineering Research Center (EERC) University of California, Berkeley. Comparative data obtained from public sources includes ICC-ES Reports, product literature and Web sites.
Testing and evaluation performed at the University at Buffalo (SUNY), the Department of Civil, Structural and Environmental Engineering – Structural Engineering and Earthquake Simulation Laboratory (SEESL) and the Earthquake Engineering Research Center (EERC) University of California, Berkeley qualify the performance of these systems according to the AC156 – Seismic Qualification Specification, and AC368 – Acceptance Criteria for Suspended Ceiling Framing Systems. Several alternative materials, designs and methods of construction were evaluated and tested. Results of this investigation indicate that these tested alternative designs are at least the equivalent of that prescribed in the code for quality, strength, effectiveness, fire resistance, durability and safety. The data and test results presented provide technical evidence on which a code official can base approval. Construction details for these systems are shown on the following pages.
A complete range of USG ceiling systems was subjected to various levels of earthquake acceleration levels for the purpose of seismic qualification. The experimental studies were performed in the University at Buffalo (SUNY) the department of Civil, Structural and Environmental Engineering • Structural Engineering and Earthquake Simulation Laboratory (SEESL) and the Earthquake Engineering Research Center (EERC) University of California, Berkeley using an earthquake simulator. System performance was certified to tolerate forces in seismic Categories D, E and F that exceeded the minimum pass criterion of AC156 and AC368 by 42%.
With these certified IBC-compliant assemblies, USG Boral ME is the only manufacturer to offer:• A seismic system that exceeds the minimum pass criterion of AC156 and AC368 by more than 42%.• Seismic-system weights commensurate with typical ceiling systems.• A seismic clip laboratory-tested to greatly exceed all structural and seismic requirements including tension,compression and tee fallout.• Compliant systems tested and verified by two separate earthquake engineering laboratories.
CODE APPROVAL
TESTING
Testing per ICC Evaluation Service, Inc. (ICC-ES) AC156 and AC368:
Seismic Design Category
System Design
D,E,F
C
System DXL-H
System DXL-I-C
12.2 kg/m2
11 kg/m2
Heavy Duty
Intermediate Duty
Passed
Passed
Maximum Ceiling System Weight Tested
Allowed Suspension System Load Carrying Capacity
Test Result
-
DONN® SUSPENSION SYSTEM SEISMIC SOLUTIONS
176
Convenience holes located in the tee bulb may be used for any and all hanger wires. Load tests performed on 12-gauge hanger wires through convenience holes found the failure to be in excess of 180kg. This far exceeds the required 90kg. The performance of DONN® seismic systems is based on the specific combination of superior components, and design and installation methods shown. Components from other manufacturers were not evaluated, and their use or any mixed use is not recommended.
SEISMIC TEST RESULTS
System DXL-HSystem Design
D, E, F
DONN® double-web,galvanized steel meeting or hot-dipped exceeding ASTM C635
Heavy Duty
22mm
ACM7
Six degrees of freedom
Simulated earthquake
AC156 and AC368
Passed
Exceeds by 42%
Fastener attachment to tee through slot
optional), no fastener through wall molding
Fastener attachment to tee (optional), one fastener through wall molding (optional)
Yes
No
12.2kg/m2
Seismic Category
Suspension System
Duty rating
Wall molding
Seismic Clip
Shake Table
Test Protocol
Qualification
Result
Minimum Acceleration Requirement
Two Adjacent Floating Sides – With Gap
Two Adjacent Fixed Sides – Tight, No Gap
Perimeter Wires
Stabilizer Bars
System Weight
D, E, F
DONN® double-web, hot-dipped galvanized steel meeting or exceeding ASTM C635
Heavy Duty
22mm
ACM7
Six degrees of freedom
Simulated earthquake
AC156 and AC368
Passed
Exceeds by 42%
Fastener attachment to tee through slot
optional), no fastener through wall molding
Fastener attachment to tee (optional), one fastener through wall molding (optional)
Yes
No
12.2kg/m2
System DXL-I-C
Categories D, E, and F Category C as per IBC
-
Convenience holes located in the tee bulb may be used for any and all hanger wires. Load tests performed on 12-gauge hanger wires through convenience holes found the failure to be in excess of 180kg. This far exceeds the required 90kg. The performance of DONN® seismic systems is based on the specific combination of superior components, and design and installation methods shown. Components from other manufacturers were not evaluated, and their use or any mixed use is not recommended.
SYSTEMS SUMMARY Category D,E,F Alternate Seismic Application
Category C Alternate Seismic Application
DXL-H
Heavy Duty DXL-H System 22mm Molding
Heavy
22mm
ACM7
ACM7 seismic clip with fastener attachment to tee through slot (optional), and no fastener through wall molding
ACM7 seismic clip with fastener attachment to tee (optional), and one fastener through wall molding (optional)
Yes
None
DXL-I-C
intermediate Duty System 22mm Molding
Heavy
22mm
ACM7
ACM7 seismic clip with fastener attachment to tee through slot (optional), and no fastener through wall molding
ACM7 seismic clip with fastener attachment to tee (optional), and one fastener through wall molding (optional)
Yes
None
Heavy Duty System 5mm Molding
Heavy
5mm
None
No attachment of tee to molding
Pop-rivet attachment of tee to molding
Yes
Yes
Intermediate Duty System 22mm Molding, Stabilizer Bars
Heavy
5mm
None (unless utilized in lieu of stabilizer bar)
No attachment of tee to molding
Pop-rivet attachment of tee to molding
None
Yes
Standard Seismic Application
Standard Seismic Application
177
Suspension System Duty Rating
Wall Molding
Seismic Clip
Two Adjacent Floating Sides – With Gap
Two Adjacent Fixed Sides –
Tight, No Gap0
Perimeter Hanger Wires
Stabilizer Bars
Suspension System Duty Rating
Wall Molding
Seismic Clip
Two Adjacent Floating Sides – With Gap
Two Adjacent Fixed Sides –
Tight, No Gap0
Perimeter Hanger Wires
Stabilizer Bars
-
DONN® SUSPENSION SYSTEM SEISMIC SOLUTIONS
178
All main DONN® suspension systems – DX/DXL, Fineline DXF, Fineline 1/8 DXFF, Centricitee DXT/DXLT, CE, DXW, DXLA, and ZXLA – include the Code compliment and heavy-duty main tees for SeismicDesign Categories D, E, and F.
For ceiling areas exceeding (232 m2), a seismic separation joint may be required. See SC2496 for information on seismic separation joints.
The performance of DONN® seismic systems is based on the specific combination of superior components, and design and installation methods shown. Components from other manufacturers were not evaluated, and their use or any mixed use is not recommended.
Convenience holes located in the tee bulb may be used for any and all hanger wires.
SYSTEMSUMMARY
CONSTRUCTION DETAILS
Suspension System Duty Rating
Wall Molding
Seismic Clip
Two Adjacent Floating Sides – With Gap
Two Adjacent Fixed Sides – Tight, No Gap
Perimeter Hanger Wires
Stabilizer Bars
Heavy
22mm
ACM7
3/49 gap; ACM7 seismic clip with fastener attachment to tee through slot (optional), and no fastener through wall molding.
Tight, no gap; ACM7 seismic clip with fastener attachment to tee (optional), and one fastener through wall molding (optional)
Yes
None
Categories D, E, and F Category C as per IBC
-
ACM7 CLIP, TIGHT WALL
179
-
DONN® SUSPENSION SYSTEM SEISMIC SOLUTIONS
180
All main DONN® suspension systems – DX/DXL, Fineline DXF, Fineline 1/8 DXFF, Centricitee DXT/DXLT, CE, DXW, DXLA, and ZXLA – include the Code compliment heavy-duty main tees for Seismic Design Categories D, E, and F.
For ceiling areas exceeding 232 m2, a seismic separation joint may be required. See SC2496 for information on seismic separation joints.
The performance of DONN® seismic systems is based on the specific combination of superior components, and design and installation methods shown. Components from other manufacturers were not evaluated, and their use or any mixed use is not recommended.
Convenience holes located in the tee bulb may be used for any and all hanger wires.
SYSTEMSUMMARY
CONSTRUCTION DETAILS
Suspension System Duty Rating
Wall Molding
Seismic Clip
Two Adjacent Floating Sides – With Gap
Two Adjacent Fixed Sides – Tight, No Gap
Perimeter Hanger Wires
Stabilizer Bars
Heavy
5mm
ACM7
None (unless utilized in lieu of stabilizer bars)
19mm gap; no attachment of tee to molding
Yes
Yes
Categories D, E, and F Category C as per IBC
-
Preformed corners are available, eliminating the need to miter this molding.
For more information about the MS274 5mm seismic shadow molding, see Seismic Mold data sheet (AC3184) or Ceiling Systems catalogue (SC2000).
With a 19mm reveal located by the wall to disguise its width, 5mm shadow molding provides an aesthetically pleasing option to traditional 5mm seismic molding. Designed for use with 24mm exposed DONN® DX/DXL suspension systems, this seismic shadow molding meets or exceeds all national code requirements and fulfills requirements for Seismic Design Categories D, E, and F.
ACM7 CLIP, TIGHT WALL
5MM SEISMIC SHADOW MOLDING
181
Pop Rivet, Tight Wall
MS274
Tee Unattached, Floating Wall
22mm
7mm
19mm32mm
Profile
Inside Corner Molding Outside Corner Molding
-
CATEGORY CALTERNATE SEISMIC APPLICATION
182
Intermediate Duty DXL-I-C System 22mm Molding
All main DONN® suspension systems – DX/DXL, Fineline DXF, Fineline 1/8 DXFF, Centricitee DXT/DXLT, CE, DXW, DXLA, and ZXLA – include the Code compliment intermediate-duty main tees for Seismic Design Categories A, B and C.
The performance of DONN® seismic systems is based on the specific combination of superior components, and design and installation methods shown. Components from other manufacturers were not evaluated, and their use or any mixed use is not recommended.
Convenience holes located in the tee bulb may beused for any and all hanger wires.Alternate Seismic Application
SYSTEMSUMMARY
CONSTRUCTION DETAILS
ACM 7 CLIP, FLOATING WALLS
Suspension System Duty Rating
Wall Molding
Seismic Clip
Two Adjacent Floating Sides – With Gap
Two Adjacent Fixed Sides – Tight, No Gap
Perimeter Hanger Wires
Stabilizer Bars
Intermediate
22mm
ACM7
ACM7 seismic clip with fastener attachment to tee through slot (optional), and one fastener through wall molding (optional).
Tight, no gap; pop-rivet attachment of tee to molding
None
None
-
CATEGORY CSTANDARD SEISMIC APPLICATION
ACM 7 CLIP, FLOATING WALLS
Intermediate
22mm
None
10mm gap; no attachment of tee to molding
None
Yes
CONSTRUCTION DETAILS
183
SYSTEMSUMMARY
Suspension System Duty Rating
Wall Molding
Seismic Clip
Floating Sides
Perimeter Hanger Wires
Stabilizer Bars
All main DONN® suspension systems – DX/DXL, Fineline DXF, Fineline 1/8 DXFF, Centricitee DXT/DXLT, CE, DXW, DXLA, and ZXLA – include the Code compliment intermediate-duty main tees for Seismic Design Categories A, B and C.
The performance of DONN® seismic systems is based on the specific combination of superior components, and design and installation methods shown. Components from other manufacturers were not evaluated, and their use or any mixed use is not recommended.
Convenience holes located in the tee bulb may beused for any and all hanger wires.Standard Seismic Application
Intermediate Duty System 22mm Molding, Stabilizer Bars