3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI DEHIWALA
Table: 04
Descriptions Required Specification
Biddersresponse If 'No” indicate the bidders offered
Yes NoMake Mention Yes Solar LeadingModel No Mention Yes SL6P60-250WCountry of Origin Mention Yes ChinaDimension Mention Yes 1640x992x40mmTotal Area Required Mention Yes 1.626m2
Weight Mention Yes 19.0kgOutput Cables Mention Yes TUV 1x4mm2 / UL12AWG; Length, 900mmPanel Capacity 250 Wp or Grater Yes 250WPNo. of Module Required Mention Yes 272Panel Voltage(Nominal) Mention Yes 30.0VMaximum PowerVoltage
MentionYes 30.5V
Maximum PowerCurrent
MentionYes 8.21A
Open Circuit Voltage Mention Yes 37.6VShort Circuit Current Mention Yes 8.67C
Nominal Operating CellTemperature(NOCT)
MentionYes 45°C+2°C
Working Temperature 0' C to 85" C Yes -40 ~ +85°C
Average Cell Efficiency Minimum 16'll Yes 17.98%Module Efficiency Mention Yes 15.37%Cell Type Mono/Poly Yes Poly 156x156mm (6 inch)Junction Box Sealable and moisture
resistance Yes IP 65
IP65 YesAluminum or resist tocorrosion Yes Anodized aluminum alloy
Front Glass 3.2 mm tempered hl bhtransmission glass. Lowiron
Yes
Product Warranty 12 Years or more YesLinear Performance Depreciation Rate. . ... ...
%Yes 10%
Expected Life time 25 Years YesNumber of bypass diodes
Mention Yes 6/6 pcsStandard IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent Yes
Quality Management ISO 9001 : 2008 orEquivalent
Yes
Name of the Bidder : Signature of the Bidder : Date : Common Seal
Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER
No Description Specified Particulars
I Name of the supplier Mention EWIS Peripherals (Pvt) Ltd2 Supplier Registration
No.Mention
PV10130
3 Inverter manufacturer Mention Solar Leading4 Country of origin Mention ChinaS Independent Agency
of submitting test reports
MentionTUV/ROHS/ISO
6 1s an accredited agency Mention Yes7 Model No. Mention Suntree17000TL8 Inverter Technology Transformer less Yes
Inverter Type Single or 3 Phase Three phase
9 Proposed SeparateCapacity
Mention17KW
10No. of InverterRequired
Mention4
11Operating TemperatureRange
Mention-25°C + 60°C
12 Cooling Method Mention Fan cooling
13 Protection Rating IP — 65 Yes
14 DC Protection Required Yes15 AC Protection Required Yes
16Lightning SurgeProtection
RequiredYes
17 Relative Humidity 4% - I 040 o Yes
18 Maximum Efficiency Minimum 97% 98.2%
19 MPPT Voltage Range DC Volt Minimum to Maximum 250-800VDC
20Maximum InputVoltage
DC(Mention)1000 VDC
21Minimum InputVoltage/Start — up Input Voltage
DC(Mention)250 VDC
22Maximum ContinuesOutput Current
AC(Mention)33.3 A
23 Rated Grid Voltage AC 230 V 230V24 Rated Grid Frequency 50 Hz Yes
25Maximum AC OutputApparent Power
Mention17,000 W
26 Power Factor Mention 0.9 (lead) – 0.99 (lag)27 Short Circuit Proof Mention N/A
28Internal Consumptionat Night
Mention0
29 MentionN/A
30 Reverse Polarity Protection
Mention Yes
31 Standards should be provided
Safety, EMC Emission, EMC Immunity, EMC Harmonic & Flicker, Automatics Grid Disconnections
Yes
32 Supported Standards IEEE 1547-2003 Grid Code/CEB InverterUnit Ref. Value Ref. Value Ref. of test certificates Value
33 Rated power output kW 20 Hz 50 IEC, IEEE 20kW34 Syncronization w.r.t
Prevailing voltage level
% 4.1.3 +/-5%+/-5%
No Description Specified Particulars
35 Over voltage and under Voltage tripping conditions
V 6.2.2 Unless
With 6% of
230
6%
a. Clearing time to abnormal Voltages (% of base Voltage)
s 4.2.3
I. V<50 s N/A
II. 50<=V<88 s <2.00 N/A
III. 1 10<=V<120 s <1.00 N/A
IV. V>—120 s <0.2
36 Over and under frequency Tripping conditions
Hz 6.2.2 Unless
Within 47-52
47-52
b. Clearing time to Abnormal frequencies <—30 Kw (in Hz)
s
N/A
I. >52 s 0.2 N/A
11. <{49.5-47} (adjustable set point
s Adjustableto
<0.2-3011
<0.2-300
37 Capability to withstand
voltage w.r.t. to the
interconnection
% 4.1.8.3
220% 6.3 220%
220%
38 Grounding scheme 4. 1.2 TT system TT
39 Reconnection time s 4.2.6 Adjustable
E up to
300
6.2.2 >180
>180
40 Limitation of dc injection
current w.r,t. full
rated output current
at the point
% .3.1 <0.5
N/A
41 Output voltage waveform 6.6 50Hz,
sinusoidalSine wave
No Description Specified Particulars42 Power quality
Measurements as per IEC 61400-21
6.11 Required Yes
43 Harmonic Distortion % 4.3.3 6.7a. H<11 % <4 <4 N/Ab. 11<h<17 % <2 <2 N/Ac. 17<h<23 % <1.5 <1.5 N/Ad. 23<h<35 % <0.6 <0.6 N/Ae. 35<h % <0.3 <0.3 N/Af. THD <5 <5 <3%
44 Emission of inter harmonic Currents from the power electronic converter as per grid code
6.11 RequiredSubmit
separately
Name of the Bidder : Signature of the Bidder : Date : Common Seal
3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI KANDY
Table: 04
Descriptions Required Specification
Biddersresponse If 'No” indicate the bidders offered
Yes NoMake Mention Yes Solar LeadingModel No Mention Yes SL6P60-250WCountry of Origin Mention Yes ChinaDimension Mention Yes 1640x992x40mmTotal Area Required Mention Yes 1.626m2
Weight Mention Yes 19.0kgOutput Cables Mention Yes TUV 1x4mm2 / UL12AWG; Length, 900mmPanel Capacity 250 Wp or Grater Yes 250WPNo. of Module Required Mention Yes 100Panel Voltage(Nominal) Mention Yes 30.0VMaximum PowerVoltage
MentionYes 30.5V
Maximum PowerCurrent
MentionYes 8.21A
Open Circuit Voltage Mention Yes 37.6VShort Circuit Current Mention Yes 8.67C
Nominal Operating CellTemperature(NOCT)
MentionYes 45°C+2°C
Working Temperature 0' C to 85" C Yes -40 ~ +85°C
Average Cell Efficiency Minimum 16'll Yes 17.98%Module Efficiency Mention Yes 15.37%Cell Type Mono/Poly Yes Poly 156x156mm (6 inch)Junction Box Sealable and moisture
resistance Yes IP 65
IP65 YesAluminum or resist tocorrosion Yes Anodized aluminum alloy
Front Glass 3.2 mm tempered hl bhtransmission glass. Lowiron
Yes
Product Warranty 12 Years or more YesLinear Performance Depreciation Rate. . ... ...
%Yes 10%
Expected Life time 25 Years YesNumber of bypass diodes
Mention Yes 6/6 pcsStandard IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent Yes
Quality Management ISO 9001 : 2008 orEquivalent
Yes
Name of the Bidder : Signature of the Bidder : Date : Common Seal
Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER
No Description Specified Particulars
I Name of the supplier Mention EWIS Peripherals (Pvt) Ltd2 Supplier Registration
No.Mention
PV10130
3 Inverter manufacturer Mention Solar Leading4 Country of origin Mention ChinaS Independent Agency
of submitting test reports
MentionTUV/ROHS/ISO
6 1s an accredited agency Mention Yes7 Model No. Mention Suntree 10000TL,15000TL8 Inverter Technology Transformer less Yes
Inverter Type Single or 3 Phase Three phase
9 Proposed SeparateCapacity
Mention10KW,15KW
10No. of InverterRequired
Mention1,1
11Operating TemperatureRange
Mention-25°C + 60°C
12 Cooling Method Mention Fan cooling
13 Protection Rating IP — 65 Yes
14 DC Protection Required Yes15 AC Protection Required Yes
16Lightning SurgeProtection
RequiredYes
17 Relative Humidity 4% - I 040 o Yes
18 Maximum Efficiency Minimum 97% 98.2%
19 MPPT Voltage Range DC Volt Minimum to Maximum 250-800VDC
20Maximum InputVoltage
DC(Mention)1000 VDC
21Minimum InputVoltage/Start — up Input Voltage
DC(Mention)250 VDC
22Maximum ContinuesOutput Current
AC(Mention)33.3 A
23 Rated Grid Voltage AC 230 V 230V24 Rated Grid Frequency 50 Hz Yes
25Maximum AC OutputApparent Power
Mention10,000 W,15000W
26 Power Factor Mention 0.9 (lead) – 0.99 (lag)27 Short Circuit Proof Mention N/A
28Internal Consumptionat Night
Mention0
29 MentionN/A
30 Reverse Polarity Protection
Mention Yes
31 Standards should be provided
Safety, EMC Emission, EMC Immunity, EMC Harmonic & Flicker, Automatics Grid Disconnections
Yes
32 Supported Standards IEEE 1547-2003 Grid Code/CEB InverterUnit Ref. Value Ref. Value Ref. of test certificates Value
33 Rated power output kW 20 Hz 50 IEC, IEEE 20kW34 Syncronization w.r.t
Prevailing voltage level
% 4.1.3 +/-5%+/-5%
No Description Specified Particulars
35 Over voltage and under Voltage tripping conditions
V 6.2.2 Unless
With 6% of
230
6%
c. Clearing time to abnormal Voltages (% of base Voltage)
s 4.2.3
I. V<50 s N/A
II. 50<=V<88 s <2.00 N/A
III. 1 10<=V<120 s <1.00 N/A
IV. V>—120 s <0.2
36 Over and under frequency Tripping conditions
Hz 6.2.2 Unless
Within 47-52
47-52
d. Clearing time to Abnormal frequencies <—30 Kw (in Hz)
s
N/A
II. >52 s 0.2 N/A
11. <{49.5-47} (adjustable set point
s Adjustableto
<0.2-3011
<0.2-300
37 Capability to withstand
voltage w.r.t. to the
interconnection
% 4.1.8.3
220% 6.3 220%
220%
38 Grounding scheme 4. 1.2 TT system TT
39 Reconnection time s 4.2.6 Adjustable
E up to
300
6.2.2 >180
>180
40 Limitation of dc injection
current w.r,t. full
rated output current
at the point
% .3.1 <0.5
N/A
41 Output voltage waveform 6.6 50Hz,
sinusoidalSine wave
No Description Specified Particulars42 Power quality
Measurements as per IEC 61400-21
6.11 Required Yes
43 Harmonic Distortion % 4.3.3 6.7a. H<11 % <4 <4 N/Ab. 11<h<17 % <2 <2 N/Ac. 17<h<23 % <1.5 <1.5 N/Ad. 23<h<35 % <0.6 <0.6 N/Ae. 35<h % <0.3 <0.3 N/Af. THD <5 <5 <3%
44 Emission of inter harmonic Currents from the power electronic converter as per grid code
6.11 RequiredSubmit
separately
Name of the Bidder : Signature of the Bidder : Date : Common Seal
3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI GALLE
Table: 04
Descriptions Required Specification
Biddersresponse If 'No” indicate the bidders offered
Yes NoMake Mention Yes Solar LeadingModel No Mention Yes SL6P60-250WCountry of Origin Mention Yes ChinaDimension Mention Yes 1640x992x40mmTotal Area Required Mention Yes 1.626m2
Weight Mention Yes 19.0kgOutput Cables Mention Yes TUV 1x4mm2 / UL12AWG; Length, 900mmPanel Capacity 250 Wp or Grater Yes 250WPNo. of Module Required Mention Yes 172Panel Voltage(Nominal) Mention Yes 30.0VMaximum PowerVoltage
MentionYes 30.5V
Maximum PowerCurrent
MentionYes 8.21A
Open Circuit Voltage Mention Yes 37.6VShort Circuit Current Mention Yes 8.67C
Nominal Operating CellTemperature(NOCT)
MentionYes 45°C+2°C
Working Temperature 0' C to 85" C Yes -40 ~ +85°C
Average Cell Efficiency Minimum 16'll Yes 17.98%Module Efficiency Mention Yes 15.37%Cell Type Mono/Poly Yes Poly 156x156mm (6 inch)Junction Box Sealable and moisture
resistance Yes IP 65
IP65 YesAluminum or resist tocorrosion Yes Anodized aluminum alloy
Front Glass 3.2 mm tempered hl bhtransmission glass. Lowiron
Yes
Product Warranty 12 Years or more YesLinear Performance Depreciation Rate. . ... ...
%Yes 10%
Expected Life time 25 Years YesNumber of bypass diodes
Mention Yes 6/6 pcsStandard IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent Yes
Quality Management ISO 9001 : 2008 orEquivalent
Yes
Name of the Bidder : Signature of the Bidder : Date : Common Seal
Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER
No Description Specified Particulars
I Name of the supplier Mention EWIS Peripherals (Pvt) Ltd2 Supplier Registration
No.Mention
PV10130
3 Inverter manufacturer Mention Solar Leading4 Country of origin Mention ChinaS Independent Agency
of submitting test reports
MentionTUV/ROHS/ISO
6 1s an accredited agency Mention Yes7 Model No. Mention Suntree 20000TL8 Inverter Technology Transformer less Yes
Inverter Type Single or 3 Phase Three phase
9 Proposed SeparateCapacity
Mention20KW
10No. of InverterRequired
Mention1
11Operating TemperatureRange
Mention-25°C + 60°C
12 Cooling Method Mention Fan cooling
13 Protection Rating IP — 65 Yes
14 DC Protection Required Yes15 AC Protection Required Yes
16Lightning SurgeProtection
RequiredYes
17 Relative Humidity 4% - I 040 o Yes
18 Maximum Efficiency Minimum 97% 98.2%
19 MPPT Voltage Range DC Volt Minimum to Maximum 250-800VDC
20Maximum InputVoltage
DC(Mention)1000 VDC
21Minimum InputVoltage/Start — up Input Voltage
DC(Mention)250 VDC
22Maximum ContinuesOutput Current
AC(Mention)33.3 A
23 Rated Grid Voltage AC 230 V 230V24 Rated Grid Frequency 50 Hz Yes
25Maximum AC OutputApparent Power
Mention20,000 W
26 Power Factor Mention 0.9 (lead) – 0.99 (lag)27 Short Circuit Proof Mention N/A
28Internal Consumptionat Night
Mention0
29 MentionN/A
30 Reverse Polarity Protection
Mention Yes
31 Standards should be provided
Safety, EMC Emission, EMC Immunity, EMC Harmonic & Flicker, Automatics Grid Disconnections
Yes
32 Supported Standards IEEE 1547-2003 Grid Code/CEB InverterUnit Ref. Value Ref. Value Ref. of test certificates Value
33 Rated power output kW 20 Hz 50 IEC, IEEE 20kW34 Syncronization w.r.t
Prevailing voltage level
% 4.1.3 +/-5%+/-5%
No Description Specified Particulars
35 Over voltage and under Voltage tripping conditions
V 6.2.2 Unless
With 6% of
230
6%
e. Clearing time to abnormal Voltages (% of base Voltage)
s 4.2.3
I. V<50 s N/A
II. 50<=V<88 s <2.00 N/A
III. 1 10<=V<120 s <1.00 N/A
IV. V>—120 s <0.2
36 Over and under frequency Tripping conditions
Hz 6.2.2 Unless
Within 47-52
47-52
f. Clearing time to Abnormal frequencies <—30 Kw (in Hz)
s
N/A
III. >52 s 0.2 N/A
11. <{49.5-47} (adjustable set point
s Adjustableto
<0.2-3011
<0.2-300
37 Capability to withstand
voltage w.r.t. to the
interconnection
% 4.1.8.3
220% 6.3 220%
220%
38 Grounding scheme 4. 1.2 TT system TT
39 Reconnection time s 4.2.6 Adjustable
E up to
300
6.2.2 >180
>180
40 Limitation of dc injection
current w.r,t. full
rated output current
at the point
% .3.1 <0.5
N/A
41 Output voltage waveform 6.6 50Hz,
sinusoidalSine wave
No Description Specified Particulars42 Power quality
Measurements as per IEC 61400-21
6.11 Required Yes
43 Harmonic Distortion % 4.3.3 6.7a. H<11 % <4 <4 N/Ab. 11<h<17 % <2 <2 N/Ac. 17<h<23 % <1.5 <1.5 N/Ad. 23<h<35 % <0.6 <0.6 N/Ae. 35<h % <0.3 <0.3 N/Af. THD <5 <5 <3%
44 Emission of inter harmonic Currents from the power electronic converter as per grid code
6.11 RequiredSubmit
separately
Name of the Bidder : Signature of the Bidder : Date : Common Seal
3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI AMPARA
Table: 04
Descriptions Required Specification
Biddersresponse If 'No” indicate the bidders offered
Yes NoMake Mention Yes Solar LeadingModel No Mention Yes SL6P60-250WCountry of Origin Mention Yes ChinaDimension Mention Yes 1640x992x40mmTotal Area Required Mention Yes 1.626m2
Weight Mention Yes 19.0kgOutput Cables Mention Yes TUV 1x4mm2 / UL12AWG; Length, 900mmPanel Capacity 250 Wp or Grater Yes 250WPNo. of Module Required Mention Yes 240Panel Voltage(Nominal) Mention Yes 30.0VMaximum PowerVoltage
MentionYes 30.5V
Maximum PowerCurrent
MentionYes 8.21A
Open Circuit Voltage Mention Yes 37.6VShort Circuit Current Mention Yes 8.67C
Nominal Operating CellTemperature(NOCT)
MentionYes 45°C+2°C
Working Temperature 0' C to 85" C Yes -40 ~ +85°C
Average Cell Efficiency Minimum 16'll Yes 17.98%Module Efficiency Mention Yes 15.37%Cell Type Mono/Poly Yes Poly 156x156mm (6 inch)Junction Box Sealable and moisture
resistance Yes IP 65
IP65 YesAluminum or resist tocorrosion Yes Anodized aluminum alloy
Front Glass 3.2 mm tempered hl bhtransmission glass. Lowiron
Yes
Product Warranty 12 Years or more YesLinear Performance Depreciation Rate. . ... ...
%Yes 10%
Expected Life time 25 Years YesNumber of bypass diodes
Mention Yes 6/6 pcsStandard IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent Yes
Quality Management ISO 9001 : 2008 orEquivalent
Yes
Name of the Bidder : Signature of the Bidder : Date : Common Seal
Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER
No Description Specified Particulars
I Name of the supplier Mention EWIS Peripherals (Pvt) Ltd2 Supplier Registration
No.Mention
PV10130
3 Inverter manufacturer Mention Solar Leading4 Country of origin Mention ChinaS Independent Agency
of submitting test reports
MentionTUV/ROHS/ISO
6 1s an accredited agency Mention Yes7 Model No. Mention Suntree 20000TL8 Inverter Technology Transformer less Yes
Inverter Type Single or 3 Phase Three phase
9 Proposed SeparateCapacity
Mention20KW
10No. of InverterRequired
Mention3
11Operating TemperatureRange
Mention-25°C + 60°C
12 Cooling Method Mention Fan cooling
13 Protection Rating IP — 65 Yes
14 DC Protection Required Yes15 AC Protection Required Yes
16Lightning SurgeProtection
RequiredYes
17 Relative Humidity 4% - I 040 o Yes
18 Maximum Efficiency Minimum 97% 98.2%
19 MPPT Voltage Range DC Volt Minimum to Maximum 250-800VDC
20Maximum InputVoltage
DC(Mention)1000 VDC
21Minimum InputVoltage/Start — up Input Voltage
DC(Mention)250 VDC
22Maximum ContinuesOutput Current
AC(Mention)33.3 A
23 Rated Grid Voltage AC 230 V 230V24 Rated Grid Frequency 50 Hz Yes
25Maximum AC OutputApparent Power
Mention20,000 W
26 Power Factor Mention 0.9 (lead) – 0.99 (lag)27 Short Circuit Proof Mention N/A
28Internal Consumptionat Night
Mention0
29 MentionN/A
30 Reverse Polarity Protection
Mention Yes
31 Standards should be provided
Safety, EMC Emission, EMC Immunity, EMC Harmonic & Flicker, Automatics Grid Disconnections
Yes
32 Supported Standards IEEE 1547-2003 Grid Code/CEB InverterUnit Ref. Value Ref. Value Ref. of test certificates Value
33 Rated power output kW 20 Hz 50 IEC, IEEE 20kW34 Syncronization w.r.t
Prevailing voltage level
% 4.1.3 +/-5%+/-5%
No Description Specified Particulars
35 Over voltage and under Voltage tripping conditions
V 6.2.2 Unless
With 6% of
230
6%
g. Clearing time to abnormal Voltages (% of base Voltage)
s 4.2.3
I. V<50 s N/A
II. 50<=V<88 s <2.00 N/A
III. 1 10<=V<120 s <1.00 N/A
IV. V>—120 s <0.2
36 Over and under frequency Tripping conditions
Hz 6.2.2 Unless
Within 47-52
47-52
h. Clearing time to Abnormal frequencies <—30 Kw (in Hz)
s
N/A
IV. >52 s 0.2 N/A
11. <{49.5-47} (adjustable set point
s Adjustableto
<0.2-3011
<0.2-300
37 Capability to withstand
voltage w.r.t. to the
interconnection
% 4.1.8.3
220% 6.3 220%
220%
38 Grounding scheme 4. 1.2 TT system TT
39 Reconnection time s 4.2.6 Adjustable
E up to
300
6.2.2 >180
>180
40 Limitation of dc injection
current w.r,t. full
rated output current
at the point
% .3.1 <0.5
N/A
41 Output voltage waveform 6.6 50Hz,
sinusoidalSine wave
No Description Specified Particulars42 Power quality
Measurements as per IEC 61400-21
6.11 Required Yes
43 Harmonic Distortion % 4.3.3 6.7a. H<11 % <4 <4 N/Ab. 11<h<17 % <2 <2 N/Ac. 17<h<23 % <1.5 <1.5 N/Ad. 23<h<35 % <0.6 <0.6 N/Ae. 35<h % <0.3 <0.3 N/Af. THD <5 <5 <3%
44 Emission of inter harmonic Currents from the power electronic converter as per grid code
6.11 RequiredSubmit
separately
Name of the Bidder : Signature of the Bidder : Date : Common Seal
3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI JAFFNA
Table: 04
Descriptions Required Specification
Biddersresponse If 'No” indicate the bidders offered
Yes NoMake Mention Yes Solar LeadingModel No Mention Yes SL6P60-250WCountry of Origin Mention Yes ChinaDimension Mention Yes 1640x992x40mmTotal Area Required Mention Yes 1.626m2
Weight Mention Yes 19.0kgOutput Cables Mention Yes TUV 1x4mm2 / UL12AWG; Length, 900mmPanel Capacity 250 Wp or Grater Yes 250WPNo. of Module Required Mention Yes 120Panel Voltage(Nominal) Mention Yes 30.0VMaximum PowerVoltage
MentionYes 30.5V
Maximum PowerCurrent
MentionYes 8.21A
Open Circuit Voltage Mention Yes 37.6VShort Circuit Current Mention Yes 8.67C
Nominal Operating CellTemperature(NOCT)
MentionYes 45°C+2°C
Working Temperature 0' C to 85" C Yes -40 ~ +85°C
Average Cell Efficiency Minimum 16'll Yes 17.98%Module Efficiency Mention Yes 15.37%Cell Type Mono/Poly Yes Poly 156x156mm (6 inch)Junction Box Sealable and moisture
resistance Yes IP 65
IP65 YesAluminum or resist tocorrosion Yes Anodized aluminum alloy
Front Glass 3.2 mm tempered hl bhtransmission glass. Lowiron
Yes
Product Warranty 12 Years or more YesLinear Performance Depreciation Rate. . ... ...
%Yes 10%
Expected Life time 25 Years YesNumber of bypass diodes
Mention Yes 6/6 pcsStandard IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent Yes
Quality Management ISO 9001 : 2008 orEquivalent
Yes
Name of the Bidder : Signature of the Bidder : Date : Common Seal
Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER
No Description Specified Particulars
I Name of the supplier Mention EWIS Peripherals (Pvt) Ltd2 Supplier Registration
No.Mention
PV10130
3 Inverter manufacturer Mention Solar Leading4 Country of origin Mention ChinaS Independent Agency
of submitting test reports
MentionTUV/ROHS/ISO
6 1s an accredited agency Mention Yes7 Model No. Mention Suntree 30000TL8 Inverter Technology Transformer less Yes
Inverter Type Single or 3 Phase Three phase
9 Proposed SeparateCapacity
Mention30
10No. of InverterRequired
Mention1
11Operating TemperatureRange
Mention-25°C + 60°C
12 Cooling Method Mention Fan cooling
13 Protection Rating IP — 65 Yes
14 DC Protection Required Yes15 AC Protection Required Yes
16Lightning SurgeProtection
RequiredYes
17 Relative Humidity 4% - I 040 o Yes
18 Maximum Efficiency Minimum 97% 98.2%
19 MPPT Voltage Range DC Volt Minimum to Maximum 250-800VDC
20Maximum InputVoltage
DC(Mention)1000 VDC
21Minimum InputVoltage/Start — up Input Voltage
DC(Mention)250 VDC
22Maximum ContinuesOutput Current
AC(Mention)33.3 A
23 Rated Grid Voltage AC 230 V 230V24 Rated Grid Frequency 50 Hz Yes
25Maximum AC OutputApparent Power
Mention30,000 W
26 Power Factor Mention 0.9 (lead) – 0.99 (lag)27 Short Circuit Proof Mention N/A
28Internal Consumptionat Night
Mention0
29 MentionN/A
30 Reverse Polarity Protection
Mention Yes
31 Standards should be provided
Safety, EMC Emission, EMC Immunity, EMC Harmonic & Flicker, Automatics Grid Disconnections
Yes
32 Supported Standards IEEE 1547-2003 Grid Code/CEB InverterUnit Ref. Value Ref. Value Ref. of test certificates Value
33 Rated power output kW 20 Hz 50 IEC, IEEE 20kW34 Syncronization w.r.t
Prevailing voltage level
% 4.1.3 +/-5%+/-5%
No Description Specified Particulars
35 Over voltage and under Voltage tripping conditions
V 6.2.2 Unless
With 6% of
230
6%
i. Clearing time to abnormal Voltages (% of base Voltage)
s 4.2.3
I. V<50 s N/A
II. 50<=V<88 s <2.00 N/A
III. 1 10<=V<120 s <1.00 N/A
IV. V>—120 s <0.2
36 Over and under frequency Tripping conditions
Hz 6.2.2 Unless
Within 47-52
47-52
j. Clearing time to Abnormal frequencies <—30 Kw (in Hz)
s
N/A
V. >52 s 0.2 N/A
11. <{49.5-47} (adjustable set point
s Adjustableto
<0.2-3011
<0.2-300
37 Capability to withstand
voltage w.r.t. to the
interconnection
% 4.1.8.3
220% 6.3 220%
220%
38 Grounding scheme 4. 1.2 TT system TT
39 Reconnection time s 4.2.6 Adjustable
E up to
300
6.2.2 >180
>180
40 Limitation of dc injection
current w.r,t. full
rated output current
at the point
% .3.1 <0.5
N/A
41 Output voltage waveform 6.6 50Hz,
sinusoidalSine wave
No Description Specified Particulars42 Power quality
Measurements as per IEC 61400-21
6.11 Required Yes
43 Harmonic Distortion % 4.3.3 6.7a. H<11 % <4 <4 N/Ab. 11<h<17 % <2 <2 N/Ac. 17<h<23 % <1.5 <1.5 N/Ad. 23<h<35 % <0.6 <0.6 N/Ae. 35<h % <0.3 <0.3 N/Af. THD <5 <5 <3%
44 Emission of inter harmonic Currents from the power electronic converter as per grid code
6.11 RequiredSubmit
separately
Name of the Bidder : Signature of the Bidder : Date : Common Seal
3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI BATTICALOA
Table: 04
Descriptions Required Specification
Biddersresponse If 'No” indicate the bidders offered
Yes NoMake Mention Yes Solar LeadingModel No Mention Yes SL6P60-250WCountry of Origin Mention Yes ChinaDimension Mention Yes 1640x992x40mmTotal Area Required Mention Yes 1.626m2
Weight Mention Yes 19.0kgOutput Cables Mention Yes TUV 1x4mm2 / UL12AWG; Length, 900mmPanel Capacity 250 Wp or Grater Yes 250WPNo. of Module Required Mention Yes 20Panel Voltage(Nominal) Mention Yes 30.0VMaximum PowerVoltage
MentionYes 30.5V
Maximum PowerCurrent
MentionYes 8.21A
Open Circuit Voltage Mention Yes 37.6VShort Circuit Current Mention Yes 8.67C
Nominal Operating CellTemperature(NOCT)
MentionYes 45°C+2°C
Working Temperature 0' C to 85" C Yes -40 ~ +85°C
Average Cell Efficiency Minimum 16'll Yes 17.98%Module Efficiency Mention Yes 15.37%Cell Type Mono/Poly Yes Poly 156x156mm (6 inch)Junction Box Sealable and moisture
resistance Yes IP 65
IP65 YesAluminum or resist tocorrosion Yes Anodized aluminum alloy
Front Glass 3.2 mm tempered hl bhtransmission glass. Lowiron
Yes
Product Warranty 12 Years or more YesLinear Performance Depreciation Rate. . ... ...
%Yes 10%
Expected Life time 25 Years YesNumber of bypass diodes
Mention Yes 6/6 pcsStandard IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent Yes
Quality Management ISO 9001 : 2008 orEquivalent
Yes
Name of the Bidder : Signature of the Bidder : Date : Common Seal
Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER
No Description Specified Particulars
I Name of the supplier Mention EWIS Peripherals (Pvt) Ltd2 Supplier Registration
No.Mention
PV10130
3 Inverter manufacturer Mention Solar Leading4 Country of origin Mention ChinaS Independent Agency
of submitting test reports
MentionTUV/ROHS/ISO
6 1s an accredited agency Mention Yes7 Model No. Mention Suntree 5000TL8 Inverter Technology Transformer less Yes
Inverter Type Single or 3 Phase Single phase
9 Proposed SeparateCapacity
Mention5KW
10No. of InverterRequired
Mention1
11Operating TemperatureRange
Mention-25°C + 60°C
12 Cooling Method Mention Fan cooling
13 Protection Rating IP — 65 Yes
14 DC Protection Required Yes15 AC Protection Required Yes
16Lightning SurgeProtection
RequiredYes
17 Relative Humidity 4% - I 040 o Yes
18 Maximum Efficiency Minimum 97% 98.2%
19 MPPT Voltage Range DC Volt Minimum to Maximum 250-800VDC
20Maximum InputVoltage
DC(Mention)1000 VDC
21Minimum InputVoltage/Start — up Input Voltage
DC(Mention)250 VDC
22Maximum ContinuesOutput Current
AC(Mention)33.3 A
23 Rated Grid Voltage AC 230 V 230V24 Rated Grid Frequency 50 Hz Yes
25Maximum AC OutputApparent Power
Mention5,000 W
26 Power Factor Mention 0.9 (lead) – 0.99 (lag)27 Short Circuit Proof Mention N/A
28Internal Consumptionat Night
Mention0
29 MentionN/A
30 Reverse Polarity Protection
Mention Yes
31 Standards should be provided
Safety, EMC Emission, EMC Immunity, EMC Harmonic & Flicker, Automatics Grid Disconnections
Yes
32 Supported Standards IEEE 1547-2003 Grid Code/CEB InverterUnit Ref. Value Ref. Value Ref. of test certificates Value
33 Rated power output kW 20 Hz 50 IEC, IEEE 20kW34 Syncronization w.r.t
Prevailing voltage level
% 4.1.3 +/-5%+/-5%
No Description Specified Particulars
35 Over voltage and under Voltage tripping conditions
V 6.2.2 Unless
With 6% of
230
6%
k. Clearing time to abnormal Voltages (% of base Voltage)
s 4.2.3
I. V<50 s N/A
II. 50<=V<88 s <2.00 N/A
III. 1 10<=V<120 s <1.00 N/A
IV. V>—120 s <0.2
36 Over and under frequency Tripping conditions
Hz 6.2.2 Unless
Within 47-52
47-52
l. Clearing time to Abnormal frequencies <—30 Kw (in Hz)
s
N/A
VI. >52 s 0.2 N/A
11. <{49.5-47} (adjustable set point
s Adjustableto
<0.2-3011
<0.2-300
37 Capability to withstand
voltage w.r.t. to the
interconnection
% 4.1.8.3
220% 6.3 220%
220%
38 Grounding scheme 4. 1.2 TT system TT
39 Reconnection time s 4.2.6 Adjustable
E up to
300
6.2.2 >180
>180
40 Limitation of dc injection
current w.r,t. full
rated output current
at the point
% .3.1 <0.5
N/A
41 Output voltage waveform 6.6 50Hz,
sinusoidalSine wave
No Description Specified Particulars42 Power quality
Measurements as per IEC 61400-21
6.11 Required Yes
43 Harmonic Distortion % 4.3.3 6.7a. H<11 % <4 <4 N/Ab. 11<h<17 % <2 <2 N/Ac. 17<h<23 % <1.5 <1.5 N/Ad. 23<h<35 % <0.6 <0.6 N/Ae. 35<h % <0.3 <0.3 N/Af. THD <5 <5 <3%
44 Emission of inter harmonic Currents from the power electronic converter as per grid code
6.11 RequiredSubmit
separately
Name of the Bidder : Signature of the Bidder : Date : Common Seal
3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI KURUNEGALA
Table: 04
Descriptions Required Specification
Biddersresponse If 'No” indicate the bidders offered
Yes NoMake Mention Yes Solar LeadingModel No Mention Yes SL6P60-250WCountry of Origin Mention Yes ChinaDimension Mention Yes 1640x992x40mmTotal Area Required Mention Yes 1.626m2
Weight Mention Yes 19.0kgOutput Cables Mention Yes TUV 1x4mm2 / UL12AWG; Length, 900mmPanel Capacity 250 Wp or Grater Yes 250WPNo. of Module Required Mention Yes 160Panel Voltage(Nominal) Mention Yes 30.0VMaximum PowerVoltage
MentionYes 30.5V
Maximum PowerCurrent
MentionYes 8.21A
Open Circuit Voltage Mention Yes 37.6VShort Circuit Current Mention Yes 8.67C
Nominal Operating CellTemperature(NOCT)
MentionYes 45°C+2°C
Working Temperature 0' C to 85" C Yes -40 ~ +85°C
Average Cell Efficiency Minimum 16'll Yes 17.98%Module Efficiency Mention Yes 15.37%Cell Type Mono/Poly Yes Poly 156x156mm (6 inch)Junction Box Sealable and moisture
resistance Yes IP 65
IP65 YesAluminum or resist tocorrosion Yes Anodized aluminum alloy
Front Glass 3.2 mm tempered hl bhtransmission glass. Lowiron
Yes
Product Warranty 12 Years or more YesLinear Performance Depreciation Rate. . ... ...
%Yes 10%
Expected Life time 25 Years YesNumber of bypass diodes
Mention Yes 6/6 pcsStandard IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent Yes
Quality Management ISO 9001 : 2008 orEquivalent
Yes
Name of the Bidder : Signature of the Bidder : Date : Common Seal
Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER
No Description Specified Particulars
I Name of the supplier Mention EWIS Peripherals (Pvt) Ltd2 Supplier Registration
No.Mention
PV10130
3 Inverter manufacturer Mention Solar Leading4 Country of origin Mention ChinaS Independent Agency
of submitting test reports
MentionTUV/ROHS/ISO
6 1s an accredited agency Mention Yes7 Model No. Mention Suntree 20000TL8 Inverter Technology Transformer less Yes
Inverter Type Single or 3 Phase Three phase
9 Proposed SeparateCapacity
Mention20KW
10No. of InverterRequired
Mention2
11Operating TemperatureRange
Mention-25°C + 60°C
12 Cooling Method Mention Fan cooling
13 Protection Rating IP — 65 Yes
14 DC Protection Required Yes15 AC Protection Required Yes
16Lightning SurgeProtection
RequiredYes
17 Relative Humidity 4% - I 040 o Yes
18 Maximum Efficiency Minimum 97% 98.2%
19 MPPT Voltage Range DC Volt Minimum to Maximum 250-800VDC
20Maximum InputVoltage
DC(Mention)1000 VDC
21Minimum InputVoltage/Start — up Input Voltage
DC(Mention)250 VDC
22Maximum ContinuesOutput Current
AC(Mention)33.3 A
23 Rated Grid Voltage AC 230 V 230V24 Rated Grid Frequency 50 Hz Yes
25Maximum AC OutputApparent Power
Mention20,000 W
26 Power Factor Mention 0.9 (lead) – 0.99 (lag)27 Short Circuit Proof Mention N/A
28Internal Consumptionat Night
Mention0
29 MentionN/A
30 Reverse Polarity Protection
Mention Yes
31 Standards should be provided
Safety, EMC Emission, EMC Immunity, EMC Harmonic & Flicker, Automatics Grid Disconnections
Yes
32 Supported Standards IEEE 1547-2003 Grid Code/CEB InverterUnit Ref. Value Ref. Value Ref. of test certificates Value
33 Rated power output kW 20 Hz 50 IEC, IEEE 20kW34 Syncronization w.r.t
Prevailing voltage level
% 4.1.3 +/-5%+/-5%
No Description Specified Particulars
35 Over voltage and under Voltage tripping conditions
V 6.2.2 Unless
With 6% of
230
6%
m. Clearing time to abnormal Voltages (% of base Voltage)
s 4.2.3
I. V<50 s N/A
II. 50<=V<88 s <2.00 N/A
III. 1 10<=V<120 s <1.00 N/A
IV. V>—120 s <0.2
36 Over and under frequency Tripping conditions
Hz 6.2.2 Unless
Within 47-52
47-52
n. Clearing time to Abnormal frequencies <—30 Kw (in Hz)
s
N/A
VII. >52 s 0.2 N/A
11. <{49.5-47} (adjustable set point
s Adjustableto
<0.2-3011
<0.2-300
37 Capability to withstand
voltage w.r.t. to the
interconnection
% 4.1.8.3
220% 6.3 220%
220%
38 Grounding scheme 4. 1.2 TT system TT
39 Reconnection time s 4.2.6 Adjustable
E up to
300
6.2.2 >180
>180
40 Limitation of dc injection
current w.r,t. full
rated output current
at the point
% .3.1 <0.5
N/A
41 Output voltage waveform 6.6 50Hz,
sinusoidalSine wave
No Description Specified Particulars42 Power quality
Measurements as per IEC 61400-21
6.11 Required Yes
43 Harmonic Distortion % 4.3.3 6.7a. H<11 % <4 <4 N/Ab. 11<h<17 % <2 <2 N/Ac. 17<h<23 % <1.5 <1.5 N/Ad. 23<h<35 % <0.6 <0.6 N/Ae. 35<h % <0.3 <0.3 N/Af. THD <5 <5 <3%
44 Emission of inter harmonic Currents from the power electronic converter as per grid code
6.11 RequiredSubmit
separately
Name of the Bidder : Signature of the Bidder : Date : Common Seal
3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI KEGALLE
Table: 04
Descriptions Required Specification
Biddersresponse If 'No” indicate the bidders offered
Yes NoMake Mention Yes Solar LeadingModel No Mention Yes SL6P60-250WCountry of Origin Mention Yes ChinaDimension Mention Yes 1640x992x40mmTotal Area Required Mention Yes 1.626m2
Weight Mention Yes 19.0kgOutput Cables Mention Yes TUV 1x4mm2 / UL12AWG; Length, 900mmPanel Capacity 250 Wp or Grater Yes 250WPNo. of Module Required Mention Yes 32Panel Voltage(Nominal) Mention Yes 30.0VMaximum PowerVoltage
MentionYes 30.5V
Maximum PowerCurrent
MentionYes 8.21A
Open Circuit Voltage Mention Yes 37.6VShort Circuit Current Mention Yes 8.67C
Nominal Operating CellTemperature(NOCT)
MentionYes 45°C+2°C
Working Temperature 0' C to 85" C Yes -40 ~ +85°C
Average Cell Efficiency Minimum 16'll Yes 17.98%Module Efficiency Mention Yes 15.37%Cell Type Mono/Poly Yes Poly 156x156mm (6 inch)Junction Box Sealable and moisture
resistance Yes IP 65
IP65 YesAluminum or resist tocorrosion Yes Anodized aluminum alloy
Front Glass 3.2 mm tempered hl bhtransmission glass. Lowiron
Yes
Product Warranty 12 Years or more YesLinear Performance Depreciation Rate. . ... ...
%Yes 10%
Expected Life time 25 Years YesNumber of bypass diodes
Mention Yes 6/6 pcsStandard IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent Yes
Quality Management ISO 9001 : 2008 orEquivalent
Yes
Name of the Bidder : Signature of the Bidder : Date : Common Seal
Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER
No Description Specified Particulars
I Name of the supplier Mention EWIS Peripherals (Pvt) Ltd2 Supplier Registration
No.Mention
PV10130
3 Inverter manufacturer Mention Solar Leading4 Country of origin Mention ChinaS Independent Agency
of submitting test reports
MentionTUV/ROHS/ISO
6 1s an accredited agency Mention Yes7 Model No. Mention Suntree 8000TL8 Inverter Technology Transformer less Yes
Inverter Type Single or 3 Phase Three phase
9 Proposed SeparateCapacity
Mention8
10No. of InverterRequired
Mention1
11Operating TemperatureRange
Mention-25°C + 60°C
12 Cooling Method Mention Fan cooling
13 Protection Rating IP — 65 Yes
14 DC Protection Required Yes15 AC Protection Required Yes
16Lightning SurgeProtection
RequiredYes
17 Relative Humidity 4% - I 040 o Yes
18 Maximum Efficiency Minimum 97% 98.2%
19 MPPT Voltage Range DC Volt Minimum to Maximum 250-800VDC
20Maximum InputVoltage
DC(Mention)1000 VDC
21Minimum InputVoltage/Start — up Input Voltage
DC(Mention)250 VDC
22Maximum ContinuesOutput Current
AC(Mention)33.3 A
23 Rated Grid Voltage AC 230 V 230V24 Rated Grid Frequency 50 Hz Yes
25Maximum AC OutputApparent Power
Mention8,000 W
26 Power Factor Mention 0.9 (lead) – 0.99 (lag)27 Short Circuit Proof Mention N/A
28Internal Consumptionat Night
Mention0
29 MentionN/A
30 Reverse Polarity Protection
Mention Yes
31 Standards should be provided
Safety, EMC Emission, EMC Immunity, EMC Harmonic & Flicker, Automatics Grid Disconnections
Yes
32 Supported Standards IEEE 1547-2003 Grid Code/CEB InverterUnit Ref. Value Ref. Value Ref. of test certificates Value
33 Rated power output kW 20 Hz 50 IEC, IEEE 20kW34 Syncronization w.r.t
Prevailing voltage level
% 4.1.3 +/-5%+/-5%
No Description Specified Particulars
35 Over voltage and under Voltage tripping conditions
V 6.2.2 Unless
With 6% of
230
6%
o. Clearing time to abnormal Voltages (% of base Voltage)
s 4.2.3
I. V<50 s N/A
II. 50<=V<88 s <2.00 N/A
III. 1 10<=V<120 s <1.00 N/A
IV. V>—120 s <0.2
36 Over and under frequency Tripping conditions
Hz 6.2.2 Unless
Within 47-52
47-52
p. Clearing time to Abnormal frequencies <—30 Kw (in Hz)
s
N/A
VIII. >52 s 0.2 N/A
11. <{49.5-47} (adjustable set point
s Adjustableto
<0.2-3011
<0.2-300
37 Capability to withstand
voltage w.r.t. to the
interconnection
% 4.1.8.3
220% 6.3 220%
220%
38 Grounding scheme 4. 1.2 TT system TT
39 Reconnection time s 4.2.6 Adjustable
E up to
300
6.2.2 >180
>180
40 Limitation of dc injection
current w.r,t. full
rated output current
at the point
% .3.1 <0.5
N/A
41 Output voltage waveform 6.6 50Hz,
sinusoidalSine wave
No Description Specified Particulars42 Power quality
Measurements as per IEC 61400-21
6.11 Required Yes
43 Harmonic Distortion % 4.3.3 6.7a. H<11 % <4 <4 N/Ab. 11<h<17 % <2 <2 N/Ac. 17<h<23 % <1.5 <1.5 N/Ad. 23<h<35 % <0.6 <0.6 N/Ae. 35<h % <0.3 <0.3 N/Af. THD <5 <5 <3%
44 Emission of inter harmonic Currents from the power electronic converter as per grid code
6.11 RequiredSubmit
separately
Name of the Bidder : Signature of the Bidder : Date : Common Seal
3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI TRINCOMALEE
Table: 04
Descriptions Required Specification
Biddersresponse If 'No” indicate the bidders offered
Yes NoMake Mention Yes Solar LeadingModel No Mention Yes SL6P60-250WCountry of Origin Mention Yes ChinaDimension Mention Yes 1640x992x40mmTotal Area Required Mention Yes 1.626m2
Weight Mention Yes 19.0kgOutput Cables Mention Yes TUV 1x4mm2 / UL12AWG; Length, 900mmPanel Capacity 250 Wp or Grater Yes 250WPNo. of Module Required Mention Yes 160Panel Voltage(Nominal) Mention Yes 30.0VMaximum PowerVoltage
MentionYes 30.5V
Maximum PowerCurrent
MentionYes 8.21A
Open Circuit Voltage Mention Yes 37.6VShort Circuit Current Mention Yes 8.67C
Nominal Operating CellTemperature(NOCT)
MentionYes 45°C+2°C
Working Temperature 0' C to 85" C Yes -40 ~ +85°C
Average Cell Efficiency Minimum 16'll Yes 17.98%Module Efficiency Mention Yes 15.37%Cell Type Mono/Poly Yes Poly 156x156mm (6 inch)Junction Box Sealable and moisture
resistance Yes IP 65
IP65 YesAluminum or resist tocorrosion Yes Anodized aluminum alloy
Front Glass 3.2 mm tempered hl bhtransmission glass. Lowiron
Yes
Product Warranty 12 Years or more YesLinear Performance Depreciation Rate. . ... ...
%Yes 10%
Expected Life time 25 Years YesNumber of bypass diodes
Mention Yes 6/6 pcsStandard IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent Yes
Quality Management ISO 9001 : 2008 orEquivalent
Yes
Name of the Bidder : Signature of the Bidder : Date : Common Seal
Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER
No Description Specified Particulars
I Name of the supplier Mention EWIS Peripherals (Pvt) Ltd2 Supplier Registration
No.Mention
PV10130
3 Inverter manufacturer Mention Solar Leading4 Country of origin Mention ChinaS Independent Agency
of submitting test reports
MentionTUV/ROHS/ISO
6 1s an accredited agency Mention Yes7 Model No. Mention Suntree 20000TL8 Inverter Technology Transformer less Yes
Inverter Type Single or 3 Phase Three phase
9 Proposed SeparateCapacity
Mention20KW
10No. of InverterRequired
Mention2
11Operating TemperatureRange
Mention-25°C + 60°C
12 Cooling Method Mention Fan cooling
13 Protection Rating IP — 65 Yes
14 DC Protection Required Yes15 AC Protection Required Yes
16Lightning SurgeProtection
RequiredYes
17 Relative Humidity 4% - I 040 o Yes
18 Maximum Efficiency Minimum 97% 98.2%
19 MPPT Voltage Range DC Volt Minimum to Maximum 250-800VDC
20Maximum InputVoltage
DC(Mention)1000 VDC
21Minimum InputVoltage/Start — up Input Voltage
DC(Mention)250 VDC
22Maximum ContinuesOutput Current
AC(Mention)33.3 A
23 Rated Grid Voltage AC 230 V 230V24 Rated Grid Frequency 50 Hz Yes
25Maximum AC OutputApparent Power
Mention20,000 W
26 Power Factor Mention 0.9 (lead) – 0.99 (lag)27 Short Circuit Proof Mention N/A
28Internal Consumptionat Night
Mention0
29 MentionN/A
30 Reverse Polarity Protection
Mention Yes
31 Standards should be provided
Safety, EMC Emission, EMC Immunity, EMC Harmonic & Flicker, Automatics Grid Disconnections
Yes
32 Supported Standards IEEE 1547-2003 Grid Code/CEB InverterUnit Ref. Value Ref. Value Ref. of test certificates Value
33 Rated power output kW 20 Hz 50 IEC, IEEE 20kW34 Syncronization w.r.t
Prevailing voltage level
% 4.1.3 +/-5%+/-5%
No Description Specified Particulars
35 Over voltage and under Voltage tripping conditions
V 6.2.2 Unless
With 6% of
230
6%
q. Clearing time to abnormal Voltages (% of base Voltage)
s 4.2.3
I. V<50 s N/A
II. 50<=V<88 s <2.00 N/A
III. 1 10<=V<120 s <1.00 N/A
IV. V>—120 s <0.2
36 Over and under frequency Tripping conditions
Hz 6.2.2 Unless
Within 47-52
47-52
r. Clearing time to Abnormal frequencies <—30 Kw (in Hz)
s
N/A
IX. >52 s 0.2 N/A
11. <{49.5-47} (adjustable set point
s Adjustableto
<0.2-3011
<0.2-300
37 Capability to withstand
voltage w.r.t. to the
interconnection
% 4.1.8.3
220% 6.3 220%
220%
38 Grounding scheme 4. 1.2 TT system TT
39 Reconnection time s 4.2.6 Adjustable
E up to
300
6.2.2 >180
>180
40 Limitation of dc injection
current w.r,t. full
rated output current
at the point
% .3.1 <0.5
N/A
41 Output voltage waveform 6.6 50Hz,
sinusoidalSine wave
No Description Specified Particulars42 Power quality
Measurements as per IEC 61400-21
6.11 Required Yes
43 Harmonic Distortion % 4.3.3 6.7a. H<11 % <4 <4 N/Ab. 11<h<17 % <2 <2 N/Ac. 17<h<23 % <1.5 <1.5 N/Ad. 23<h<35 % <0.6 <0.6 N/Ae. 35<h % <0.3 <0.3 N/Af. THD <5 <5 <3%
44 Emission of inter harmonic Currents from the power electronic converter as per grid code
6.11 RequiredSubmit
separately
Name of the Bidder : Signature of the Bidder : Date : Common Seal
3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI BADULLA
Table: 04
Descriptions Required Specification
Biddersresponse If 'No” indicate the bidders offered
Yes NoMake Mention Yes Solar LeadingModel No Mention Yes SL6P60-250WCountry of Origin Mention Yes ChinaDimension Mention Yes 1640x992x40mmTotal Area Required Mention Yes 1.626m2
Weight Mention Yes 19.0kgOutput Cables Mention Yes TUV 1x4mm2 / UL12AWG; Length, 900mmPanel Capacity 250 Wp or Grater Yes 250WPNo. of Module Required Mention Yes 60Panel Voltage(Nominal) Mention Yes 30.0VMaximum PowerVoltage
MentionYes 30.5V
Maximum PowerCurrent
MentionYes 8.21A
Open Circuit Voltage Mention Yes 37.6VShort Circuit Current Mention Yes 8.67C
Nominal Operating CellTemperature(NOCT)
MentionYes 45°C+2°C
Working Temperature 0' C to 85" C Yes -40 ~ +85°C
Average Cell Efficiency Minimum 16'll Yes 17.98%Module Efficiency Mention Yes 15.37%Cell Type Mono/Poly Yes Poly 156x156mm (6 inch)Junction Box Sealable and moisture
resistance Yes IP 65
IP65 YesAluminum or resist tocorrosion Yes Anodized aluminum alloy
Front Glass 3.2 mm tempered hl bhtransmission glass. Lowiron
Yes
Product Warranty 12 Years or more YesLinear Performance Depreciation Rate. . ... ...
%Yes 10%
Expected Life time 25 Years YesNumber of bypass diodes
Mention Yes 6/6 pcsStandard IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent Yes
Quality Management ISO 9001 : 2008 orEquivalent
Yes
Name of the Bidder : Signature of the Bidder : Date : Common Seal
Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER
No Description Specified Particulars
I Name of the supplier Mention EWIS Peripherals (Pvt) Ltd2 Supplier Registration
No.Mention
PV10130
3 Inverter manufacturer Mention Solar Leading4 Country of origin Mention ChinaS Independent Agency
of submitting test reports
MentionTUV/ROHS/ISO
6 1s an accredited agency Mention Yes7 Model No. Mention Suntree 15000TL8 Inverter Technology Transformer less Yes
Inverter Type Single or 3 Phase Three phase
9 Proposed SeparateCapacity
Mention15KW
10No. of InverterRequired
Mention1
11Operating TemperatureRange
Mention-25°C + 60°C
12 Cooling Method Mention Fan cooling
13 Protection Rating IP — 65 Yes
14 DC Protection Required Yes15 AC Protection Required Yes
16Lightning SurgeProtection
RequiredYes
17 Relative Humidity 4% - I 040 o Yes
18 Maximum Efficiency Minimum 97% 98.2%
19 MPPT Voltage Range DC Volt Minimum to Maximum 250-800VDC
20Maximum InputVoltage
DC(Mention)1000 VDC
21Minimum InputVoltage/Start — up Input Voltage
DC(Mention)250 VDC
22Maximum ContinuesOutput Current
AC(Mention)33.3 A
23 Rated Grid Voltage AC 230 V 230V24 Rated Grid Frequency 50 Hz Yes
25Maximum AC OutputApparent Power
Mention15,000 W
26 Power Factor Mention 0.9 (lead) – 0.99 (lag)27 Short Circuit Proof Mention N/A
28Internal Consumptionat Night
Mention0
29 MentionN/A
30 Reverse Polarity Protection
Mention Yes
31 Standards should be provided
Safety, EMC Emission, EMC Immunity, EMC Harmonic & Flicker, Automatics Grid Disconnections
Yes
32 Supported Standards IEEE 1547-2003 Grid Code/CEB InverterUnit Ref. Value Ref. Value Ref. of test certificates Value
33 Rated power output kW 20 Hz 50 IEC, IEEE 20kW34 Syncronization w.r.t
Prevailing voltage level
% 4.1.3 +/-5%+/-5%
No Description Specified Particulars
35 Over voltage and under Voltage tripping conditions
V 6.2.2 Unless
With 6% of
230
6%
s. Clearing time to abnormal Voltages (% of base Voltage)
s 4.2.3
I. V<50 s N/A
II. 50<=V<88 s <2.00 N/A
III. 1 10<=V<120 s <1.00 N/A
IV. V>—120 s <0.2
36 Over and under frequency Tripping conditions
Hz 6.2.2 Unless
Within 47-52
47-52
t. Clearing time to Abnormal frequencies <—30 Kw (in Hz)
s
N/A
X. >52 s 0.2 N/A
11. <{49.5-47} (adjustable set point
s Adjustableto
<0.2-3011
<0.2-300
37 Capability to withstand
voltage w.r.t. to the
interconnection
% 4.1.8.3
220% 6.3 220%
220%
38 Grounding scheme 4. 1.2 TT system TT
39 Reconnection time s 4.2.6 Adjustable
E up to
300
6.2.2 >180
>180
40 Limitation of dc injection
current w.r,t. full
rated output current
at the point
% .3.1 <0.5
N/A
41 Output voltage waveform 6.6 50Hz,
sinusoidalSine wave
No Description Specified Particulars42 Power quality
Measurements as per IEC 61400-21
6.11 Required Yes
43 Harmonic Distortion % 4.3.3 6.7a. H<11 % <4 <4 N/Ab. 11<h<17 % <2 <2 N/Ac. 17<h<23 % <1.5 <1.5 N/Ad. 23<h<35 % <0.6 <0.6 N/Ae. 35<h % <0.3 <0.3 N/Af. THD <5 <5 <3%
44 Emission of inter harmonic Currents from the power electronic converter as per grid code
6.11 RequiredSubmit
separately
Name of the Bidder : Signature of the Bidder : Date : Common Seal
3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI TANGALLE
Table: 04
Descriptions Required Specification
Biddersresponse If 'No” indicate the bidders offered
Yes NoMake Mention Yes Solar LeadingModel No Mention Yes SL6P60-250WCountry of Origin Mention Yes ChinaDimension Mention Yes 1640x992x40mmTotal Area Required Mention Yes 1.626m2
Weight Mention Yes 19.0kgOutput Cables Mention Yes TUV 1x4mm2 / UL12AWG; Length, 900mmPanel Capacity 250 Wp or Grater Yes 250WPNo. of Module Required Mention Yes 20Panel Voltage(Nominal) Mention Yes 30.0VMaximum PowerVoltage
MentionYes 30.5V
Maximum PowerCurrent
MentionYes 8.21A
Open Circuit Voltage Mention Yes 37.6VShort Circuit Current Mention Yes 8.67C
Nominal Operating CellTemperature(NOCT)
MentionYes 45°C+2°C
Working Temperature 0' C to 85" C Yes -40 ~ +85°C
Average Cell Efficiency Minimum 16'll Yes 17.98%Module Efficiency Mention Yes 15.37%Cell Type Mono/Poly Yes Poly 156x156mm (6 inch)Junction Box Sealable and moisture
resistance Yes IP 65
IP65 YesAluminum or resist tocorrosion Yes Anodized aluminum alloy
Front Glass 3.2 mm tempered hl bhtransmission glass. Lowiron
Yes
Product Warranty 12 Years or more YesLinear Performance Depreciation Rate. . ... ...
%Yes 10%
Expected Life time 25 Years YesNumber of bypass diodes
Mention Yes 6/6 pcsStandard IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent Yes
Quality Management ISO 9001 : 2008 orEquivalent
Yes
Name of the Bidder : Signature of the Bidder : Date : Common Seal
Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER
No Description Specified Particulars
I Name of the supplier Mention EWIS Peripherals (Pvt) Ltd2 Supplier Registration
No.Mention
PV10130
3 Inverter manufacturer Mention Solar Leading4 Country of origin Mention ChinaS Independent Agency
of submitting test reports
MentionTUV/ROHS/ISO
6 1s an accredited agency Mention Yes7 Model No. Mention Suntree 5000TL8 Inverter Technology Transformer less Yes
Inverter Type Single or 3 Phase Single phase
9 Proposed SeparateCapacity
Mention5
10No. of InverterRequired
Mention1
11Operating TemperatureRange
Mention-25°C + 60°C
12 Cooling Method Mention Fan cooling
13 Protection Rating IP — 65 Yes
14 DC Protection Required Yes15 AC Protection Required Yes
16Lightning SurgeProtection
RequiredYes
17 Relative Humidity 4% - I 040 o Yes
18 Maximum Efficiency Minimum 97% 98.2%
19 MPPT Voltage Range DC Volt Minimum to Maximum 250-800VDC
20Maximum InputVoltage
DC(Mention)1000 VDC
21Minimum InputVoltage/Start — up Input Voltage
DC(Mention)250 VDC
22Maximum ContinuesOutput Current
AC(Mention)33.3 A
23 Rated Grid Voltage AC 230 V 230V24 Rated Grid Frequency 50 Hz Yes
25Maximum AC OutputApparent Power
Mention5,000 W
26 Power Factor Mention 0.9 (lead) – 0.99 (lag)27 Short Circuit Proof Mention N/A
28Internal Consumptionat Night
Mention0
29 MentionN/A
30 Reverse Polarity Protection
Mention Yes
31 Standards should be provided
Safety, EMC Emission, EMC Immunity, EMC Harmonic & Flicker, Automatics Grid Disconnections
Yes
32 Supported Standards IEEE 1547-2003 Grid Code/CEB InverterUnit Ref. Value Ref. Value Ref. of test certificates Value
33 Rated power output kW 20 Hz 50 IEC, IEEE 20kW34 Syncronization w.r.t
Prevailing voltage level
% 4.1.3 +/-5%+/-5%
No Description Specified Particulars
35 Over voltage and under Voltage tripping conditions
V 6.2.2 Unless
With 6% of
230
6%
u. Clearing time to abnormal Voltages (% of base Voltage)
s 4.2.3
I. V<50 s N/A
II. 50<=V<88 s <2.00 N/A
III. 1 10<=V<120 s <1.00 N/A
IV. V>—120 s <0.2
36 Over and under frequency Tripping conditions
Hz 6.2.2 Unless
Within 47-52
47-52
v. Clearing time to Abnormal frequencies <—30 Kw (in Hz)
s
N/A
XI. >52 s 0.2 N/A
11. <{49.5-47} (adjustable set point
s Adjustableto
<0.2-3011
<0.2-300
37 Capability to withstand
voltage w.r.t. to the
interconnection
% 4.1.8.3
220% 6.3 220%
220%
38 Grounding scheme 4. 1.2 TT system TT
39 Reconnection time s 4.2.6 Adjustable
E up to
300
6.2.2 >180
>180
40 Limitation of dc injection
current w.r,t. full
rated output current
at the point
% .3.1 <0.5
N/A
41 Output voltage waveform 6.6 50Hz,
sinusoidalSine wave
No Description Specified Particulars42 Power quality
Measurements as per IEC 61400-21
6.11 Required Yes
43 Harmonic Distortion % 4.3.3 6.7a. H<11 % <4 <4 N/Ab. 11<h<17 % <2 <2 N/Ac. 17<h<23 % <1.5 <1.5 N/Ad. 23<h<35 % <0.6 <0.6 N/Ae. 35<h % <0.3 <0.3 N/Af. THD <5 <5 <3%
44 Emission of inter harmonic Currents from the power electronic converter as per grid code
6.11 RequiredSubmit
separately
Name of the Bidder : Signature of the Bidder : Date : Common Seal
3. TECHNICAL SPECIFICATIONS
SOLAR PANEL FOR ATI VEYANGODA
Table: 04
Descriptions Required Specification
Biddersresponse If 'No” indicate the bidders offered
Yes NoMake Mention Yes Solar LeadingModel No Mention Yes SL6P60-250WCountry of Origin Mention Yes ChinaDimension Mention Yes 1640x992x40mmTotal Area Required Mention Yes 1.626m2
Weight Mention Yes 19.0kgOutput Cables Mention Yes TUV 1x4mm2 / UL12AWG; Length, 900mmPanel Capacity 250 Wp or Grater Yes 250WPNo. of Module Required Mention Yes 160Panel Voltage(Nominal) Mention Yes 30.0VMaximum PowerVoltage
MentionYes 30.5V
Maximum PowerCurrent
MentionYes 8.21A
Open Circuit Voltage Mention Yes 37.6VShort Circuit Current Mention Yes 8.67C
Nominal Operating CellTemperature(NOCT)
MentionYes 45°C+2°C
Working Temperature 0' C to 85" C Yes -40 ~ +85°C
Average Cell Efficiency Minimum 16'll Yes 17.98%Module Efficiency Mention Yes 15.37%Cell Type Mono/Poly Yes Poly 156x156mm (6 inch)Junction Box Sealable and moisture
resistance Yes IP 65
IP65 YesAluminum or resist tocorrosion Yes Anodized aluminum alloy
Front Glass 3.2 mm tempered hl bhtransmission glass. Lowiron
Yes
Product Warranty 12 Years or more YesLinear Performance Depreciation Rate. . ... ...
%Yes 10%
Expected Life time 25 Years YesNumber of bypass diodes
Mention Yes 6/6 pcsStandard IEC 6 12 15 or Equivalent
IEC 6 1739 or Equivalent Yes
Quality Management ISO 9001 : 2008 orEquivalent
Yes
Name of the Bidder : Signature of the Bidder : Date : Common Seal
Inverter
SCHEDULE OF TECHNICAL PARTICULARS FOR GRID CONNECTED INVERTER
No Description Specified Particulars
I Name of the supplier Mention EWIS Peripherals (Pvt) Ltd2 Supplier Registration
No.Mention
PV10130
3 Inverter manufacturer Mention Solar Leading4 Country of origin Mention ChinaS Independent Agency
of submitting test reports
MentionTUV/ROHS/ISO
6 1s an accredited agency Mention Yes7 Model No. Mention Suntree 20000TL8 Inverter Technology Transformer less Yes
Inverter Type Single or 3 Phase Three phase
9 Proposed SeparateCapacity
Mention20
10No. of InverterRequired
Mention2
11Operating TemperatureRange
Mention-25°C + 60°C
12 Cooling Method Mention Fan cooling
13 Protection Rating IP — 65 Yes
14 DC Protection Required Yes15 AC Protection Required Yes
16Lightning SurgeProtection
RequiredYes
17 Relative Humidity 4% - I 040 o Yes
18 Maximum Efficiency Minimum 97% 98.2%
19 MPPT Voltage Range DC Volt Minimum to Maximum 250-800VDC
20Maximum InputVoltage
DC(Mention)1000 VDC
21Minimum InputVoltage/Start — up Input Voltage
DC(Mention)250 VDC
22Maximum ContinuesOutput Current
AC(Mention)33.3 A
23 Rated Grid Voltage AC 230 V 230V24 Rated Grid Frequency 50 Hz Yes
25Maximum AC OutputApparent Power
Mention20,000 W
26 Power Factor Mention 0.9 (lead) – 0.99 (lag)27 Short Circuit Proof Mention N/A
28Internal Consumptionat Night
Mention0
29 MentionN/A
30 Reverse Polarity Protection
Mention Yes
31 Standards should be provided
Safety, EMC Emission, EMC Immunity, EMC Harmonic & Flicker, Automatics Grid Disconnections
Yes
32 Supported Standards IEEE 1547-2003 Grid Code/CEB InverterUnit Ref. Value Ref. Value Ref. of test certificates Value
33 Rated power output kW 20 Hz 50 IEC, IEEE 20kW34 Syncronization w.r.t
Prevailing voltage level
% 4.1.3 +/-5%+/-5%
No Description Specified Particulars
35 Over voltage and under Voltage tripping conditions
V 6.2.2 Unless
With 6% of
230
6%
w. Clearing time to abnormal Voltages (% of base Voltage)
s 4.2.3
I. V<50 s N/A
II. 50<=V<88 s <2.00 N/A
III. 1 10<=V<120 s <1.00 N/A
IV. V>—120 s <0.2
36 Over and under frequency Tripping conditions
Hz 6.2.2 Unless
Within 47-52
47-52
x. Clearing time to Abnormal frequencies <—30 Kw (in Hz)
s
N/A
XII. >52 s 0.2 N/A
11. <{49.5-47} (adjustable set point
s Adjustableto
<0.2-3011
<0.2-300
37 Capability to withstand
voltage w.r.t. to the
interconnection
% 4.1.8.3
220% 6.3 220%
220%
38 Grounding scheme 4. 1.2 TT system TT
39 Reconnection time s 4.2.6 Adjustable
E up to
300
6.2.2 >180
>180
40 Limitation of dc injection
current w.r,t. full
rated output current
at the point
% .3.1 <0.5
N/A
41 Output voltage waveform 6.6 50Hz,
sinusoidalSine wave
No Description Specified Particulars42 Power quality
Measurements as per IEC 61400-21
6.11 Required Yes
43 Harmonic Distortion % 4.3.3 6.7a. H<11 % <4 <4 N/Ab. 11<h<17 % <2 <2 N/Ac. 17<h<23 % <1.5 <1.5 N/Ad. 23<h<35 % <0.6 <0.6 N/Ae. 35<h % <0.3 <0.3 N/Af. THD <5 <5 <3%
44 Emission of inter harmonic Currents from the power electronic converter as per grid code
6.11 RequiredSubmit
separately
Name of the Bidder : Signature of the Bidder : Date : Common Seal