Dn 068776

download Dn 068776

of 16

Transcript of Dn 068776

  • 7/28/2019 Dn 068776

    1/16

    Nokia Siemens Networks

    GSM/EDGE BSS, rel.

    RG10(BSS), operatingdocumentation, issue 04

    EXAU-A

    DN068776

    Issue 1-0

  • 7/28/2019 Dn 068776

    2/16

    2 DN068776

    Issue 1-0

    EXAU-A

    Id:0900d805804277a4

    The information in this document is subject to change without notice and describes only the

    product defined in the introduction of this documentation. This documentation is intended for the

    use of Nokia Siemens Networks customers only for the purposes of the agreement under whichthe document is submitted, and no part of it may be used, reproduced, modified or transmitted

    in any form or means without the prior written permission of Nokia Siemens Networks. The

    documentation has been prepared to be used by professional and properly trained personnel,

    and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes

    customer comments as part of the process of continuous development and improvement of the

    documentation.

    The information or statements given in this documentation concerning the suitability, capacity,

    or performance of the mentioned hardware or software products are given "as is" and all liability

    arising in connection with such hardware or software products shall be defined conclusively and

    finally in a separate agreement between Nokia Siemens Networks and the customer. However,

    Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions

    contained in the document are adequate and free of material errors and omissions. Nokia

    Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which

    may not be covered by the document.

    Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO

    EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-

    TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-

    RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED

    TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY

    OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION

    IN IT.

    This documentation and the product it describes are considered protected by copyrights and

    other intellectual property rights according to the applicable laws.

    The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark

    of Nokia Corporation. Siemens is a registered trademark of Siemens AG.

    Other product names mentioned in this document may be trademarks of their respectiveowners, and they are mentioned for identification purposes only.

    Copyright Nokia Siemens Networks 2009. All rights reserved

    f Important Notice on Product SafetyElevated voltages are inevitably present at specific points in this electrical equipment.

    Some of the parts may also have elevated operating temperatures.

    Non-observance of these conditions and the safety instructions can result in personal

    injury or in property damage.

    Therefore, only trained and qualified personnel may install and maintain the system.

    The system complies with the standard EN 60950 / IEC 60950. All equipment connected

    has to comply with the applicable safety standards.

    The same text in German:

    Wichtiger Hinweis zur Produktsicherheit

    In elektrischen Anlagen stehen zwangslufig bestimmte Teile der Gerte unter Span-

    nung. Einige Teile knnen auch eine hohe Betriebstemperatur aufweisen.

    Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Krperverlet-

    zungen und Sachschden fhren.

    Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die

    Anlagen installiert und wartet.

    Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene

    Gerte mssen die zutreffenden Sicherheitsbestimmungen erfllen.

  • 7/28/2019 Dn 068776

    3/16

    DN068776

    Issue 1-0

    3

    EXAU-A

    Id:0900d805804277a4

    Table of ContentsThis document has 16 pages.

    Summary of changes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

    1 EXAU-A overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

    2 EXAU-A structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

    3 EXAU-A operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

    4 Chaining EXAU-A units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

    5 Power consumption of EXAU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

  • 7/28/2019 Dn 068776

    4/16

    4 DN068776

    Issue 1-0

    EXAU-A

    Id:0900d805804277a4

    List of FiguresFigure 1 Dimensions and installation options of the EXAU-A . . . . . . . . . . . . . . . . . 9

    Figure 2 Interfaces of the EXAU-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

    Figure 3 Displaying the same alarms on two EXAU-A units . . . . . . . . . . . . . . . . . 14

    Figure 4 Displaying alarms from AL00 to AL05 on EXAU-A 1 and alarm from AL06

    to AL11 on EXAU-A 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

  • 7/28/2019 Dn 068776

    5/16

    DN068776

    Issue 1-0

    5

    EXAU-A

    Id:0900d805804277a4

    List of TablesTable 1 Cabling interfaces for EXAU-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

    Table 2 Default colours of alarm signals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

    Table 3 Indicator LEDs on front panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

  • 7/28/2019 Dn 068776

    6/16

    6 DN068776

    Issue 1-0

    EXAU-A

    Id:0900d805804277a4

  • 7/28/2019 Dn 068776

    7/16

    DN068776

    Issue 1-0

    7

    EXAU-A Summary of changes

    Id:0900d8058045c7ac

    Summary of changesChanges between document issues are cumulative. Therefore, the latest document

    issue contains all changes made to previous issues.

    Issue 1-0

    First issue.

  • 7/28/2019 Dn 068776

    8/16

    8 DN068776

    Issue 1-0

    EXAU-A

    Id:0900d805803582dc

    EXAU-A overview

    1 EXAU-A overview

    Main functions of EXAU-A

    The DX200 and IPA2800 network elements can be equipped with an external alarm unitto make the alarm monitoring more efficient. The External Alarm Unit (EXAU-A) is a

    small device controlled by the HWAT-A plug-in unit in the DX200 network elements of

    M98 mechanics, and the EHAT plug-in unit in the IPA2800 network elements. The

    EXAU-A indicates alarms from the network element with indicator LEDs and a buzzer.

    Normally the EXAU-As are mounted on the wall of the control room. They are easy to

    install to all common wall materials. The power supply and alarms cables can enter the

    unit from above or below the EXAU-A case, or from the upper or lower side as shown in

    figure below.

    In the DX200 M98 mechanics, the transmitter circuit of the HWAT-A is a constant current

    generator, which provides a 24 mA current when the voltage at the output is below +3

    V. The voltage at the output depends on the size of the load connected to the output andthe voltage at the other end of the load (range of variation is +5...-75 V).

    In the IPA2800 mechanics, the transmitter circuit of the EHAT is a constant current gen-

    erator, which provides a 20 mA current when the voltage at the output is below +3 V.

    The voltage at the output depends on the size of the load connected to the output and

    the voltage at the other end of the load.

    The EXAU-A also has a second D25 connector, which makes it possible to chain several

    EXAU-A units, so that the alarms can be displayed on more than one unit.

    Dimensions of the EXAU-A unit are 153 mm (W) x 212 mm (H) x 53 mm(D). The indica-

    tor LEDs have no printed markings, but the user can write the alarm identifications on

    the face of the EXAU-A.

    Network element

    mechanics

    Cable from EXAU-A

    panel

    Panel, connector Plug-in unit controlling

    EXAU-A

    DX200 i-series: DX

    MSC/DX HLR, SGSN

    CNDE CPEA, D25 HWAT-A

    BSC3i CNDC CPRJ45, D25 HWAT-A

    IPA2800; MGW, RNC CNDC CPSAL-B / CPSAL /

    CPAL, D25

    EHAT

    Table 1 Cabling interfaces for EXAU-A

  • 7/28/2019 Dn 068776

    9/16

    DN068776

    Issue 1-0

    9

    EXAU-A EXAU-A overview

    Id:0900d805803582dc

    Figure 1 Dimensions and installation options of the EXAU-A

    Operating environment of EXAU

    The EXAU-A is connected by an interconnection cable (for example, CNDC) directly to

    the alarm panel of the network element concerned or via a crossconnection (DDF) to the

    alarm panel of the network element concerned.

    The second D25 connector of the EXAU-A can be used to chain several EXAUA units

    together. This makes it possible to display the alarms on more than one unit.

    The operating voltage (-48 V) is connected by separate cable to a terminal block on the

    EXAU-A component board.

    DN05209253

    153

    153

    153

    212

    53

    Alarm 1

    Alarm 2

    Alarm 3

    Alarm 4

    Alarm 5

    Alarm 6

  • 7/28/2019 Dn 068776

    10/16

    10 DN068776

    Issue 1-0

    EXAU-A

    Id:0900d805803582dc

    EXAU-A overview

    * Alarms from AL00 to AL05 are regenerated in the Alarm Interface and forwarded

    to the Alarm Output.

    Figure 2 Interfaces of the EXAU-A

    Signals AL00...AL11 are alarm inputs. These inputs can be activated by connecting 18

    mA current through the input.

    AL00

    AL05ALARM INPUT

    EXAU-A

    AL06

    AL11

    ALARM OUTPUT

    AL00*

    AL05*

    AL06

    AL11

    To alarm panel

    0BW

    -BW

    POWER

    SUPPLY

    ALARM

    INTERFACE

    DN05209265

  • 7/28/2019 Dn 068776

    11/16

    DN068776

    Issue 1-0

    11

    EXAU-A EXAU-A structure

    Id:0900d80580423c23

    2 EXAU-A structure

    Mechanical structure of EXAU-A

    The EXAU-A panel consists of a base assembly and a cover assembly with a compo-nent board attached to it with three attachment pins. The component board accommo-

    dates also the power supply and alarm connectors.

    Functionally, the EXAU-A panel consists of the following blocks:

    component board (PCB) connected to the cover

    base frame for mounting on the wall

    alarm inputs, D25 connector on component board

    alarm output, D25 connector on component board

    six indicator LEDs connected to component board

    buzzer mounted on component board

    Test, Buzzer Reset and Silent Mode buttons connected to component board Silent Mode and Power On LEDs on the component board

    power supply (-48 V).

  • 7/28/2019 Dn 068776

    12/16

    12 DN068776

    Issue 1-0

    EXAU-A

    Id:0900d8058032b855

    EXAU-A operation

    3 EXAU-A operation

    Principles of operation

    The control section consists of D-type flip-flops and other CMOS logic.

    The alarm inputs have been optoisolated of the controlling logic. In normal state, the

    alarm inputs are open.

    Darlington transistor array is used for driving the LEDs.

    Alarms that activate the buzzer can be selected with DIP switch SW1.

    The buzzer, like the indicator LEDs, are connected to six alarm inputs.

    The buzzer can be switched off by the silent mode button. The test cutton is used to test

    the operation of the indicator LEDs and the buzzer.

    Power (-48V DC) is supplied via a protective switch SW2 and fuse F1. When the cover

    assembly is opened, the power supply to the EXAU-A unit disconnected.

    LEDs

    The EXAU-A houses six alarm indicator LEDs on the front panel. Each alarm signal

    (AL00-AL05) has an indicator LED. User can select with a DIP switch which alarms

    activate the buzzer.

    Buzzer

    A buzzer is connected to indicator LEDs. The user can select with a DIP switch on the

    component board those alarms which should activate the buzzer. There is also a Buzzer

    Resetbutton for the buzzer. The Buzzer Reset turns off the buzzer, but the buzzer turns

    back on when a new alarm signal arrives. The buzzer is set ON for all alarms by default.

    With the BUZZER SELECT jumpers on Switch SW1 the user can set the buzzer for each

    alarm (AL00 - AL05) ON or OFF.

    Colour Position Signal Alarm

    Red (1) uppermost (AL00) Alarm 1

    Yellow (2) (AL01) Alarm 2

    Green (3) (AL02) Alarm 3

    Red (4) (AL03) Alarm 4

    Yellow (5) (AL04) Alarm 5

    Blue (6) lowermost (AL05) Alarm 6

    Table 2 Default colours of alarm signals.

    Colour Signal

    Green Power on/off

    Yellow Silent Mode on/off

    Table 3 Indicator LEDs on front panel.

  • 7/28/2019 Dn 068776

    13/16

    DN068776

    Issue 1-0

    13

    EXAU-A EXAU-A operation

    Id:0900d8058032b855

    Test button

    The EXAU-A front panel accommodates a test button. With the Testbutton the user can

    check the operation of the indicator LEDs and the buzzer.

    Silent Mode button

    The EXAU-A front panel accommodates a button for Silent Mode setting. By pressing

    the Silent Mode button to down position the user can turn off the buzzer altogether.

    When the Silent Mode is on, the yellow indicator LED on the front panel will be lit.

  • 7/28/2019 Dn 068776

    14/16

    14 DN068776

    Issue 1-0

    EXAU-A

    Id:0900d80580333ebe

    Chaining EXAU-A units

    4 Chaining EXAU-A unitsThe EXAU-A unit has an alarm output connector, which makes it possible to chain

    EXAU-A units so that any alarms can be displayed on two or more EXAU-A units.

    Displaying the same alarms on two EXAU-A units

    The incoming alarms can be connected directly to the alarm output connector, which is

    then connected to another EXAU-A unit with a direct cable. This way the alarms dis-

    played on EXAU-A 1 can also be displayed on the EXAU-A 2 unit.

    Note that the direct cable is not included in the EXAU-A delivery.

    * Alarms from AL00 to AL05 are regenerated in the Alarm Interface and forwardedto the Alarm Output.

    Figure 3 Displaying the same alarms on two EXAU-A units

    Displaying alarms from AL00 to AL05 on EXAU-A 1 and alarms AL06 to AL11 on

    EXAU-A 2

    By connecting two EXAU-A units with a crossover cable that connects alarms from AL00

    to AL05 from EXAU-A 1 to alarm connectors AL06 to AL11 on EXAU-A 2, it is possible

    to display twelve different alarms on two EXAU-A units. When the units are connected

    in this manner, alarms from AL00 to AL05 will be displayed on EXAU-A 1 and alarms

    from AL06 to AL11 will be displayed on EXAU-A 2.

    Note that the crossover cable is not included in the EXAU-A delivery.

    AL00

    AL05

    ALARMINPUT

    EXAU-A 1

    AL00*

    AL05*

    ALARMOUTPUT

    EXAU-A 2

    AL00

    AL05

    ALARMINPUT

    DIRECTCABLE

    DN0617755

  • 7/28/2019 Dn 068776

    15/16

    DN068776

    Issue 1-0

    15

    EXAU-A Chaining EXAU-A units

    Id:0900d80580333ebe

    * Alarms from AL00 to AL05 are regenerated in the Alarm Interface and forwarded

    to the Alarm Output.

    Figure 4 Displaying alarms from AL00 to AL05 on EXAU-A 1 and alarm from AL06

    to AL11 on EXAU-A 2

    AL00

    AL05

    ALARMINPUT

    EXAU-A 1

    AL06

    AL11

    AL00*

    AL05*

    AL06

    AL11

    ALARMOUTPUT

    EXAU-A 2

    AL00

    AL05

    AL06

    AL11

    ALARMINPUT

    DN0617767

  • 7/28/2019 Dn 068776

    16/16

    16 DN068776

    I 1 0

    EXAU-A

    Id:0900d8058034eee2

    Power consumption of EXAU

    5 Power consumption of EXAUThe operating voltage of the EXAU-A panel is -48 V. The power consumption values are

    as follows:

    Mode Power consumption

    Idle 1.7 W (Minimum)

    1 alarm and buzzer 3.0W (Normal operation)

    All alarms and buzzer 9.1W (Maximum)